Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0041808_Application (FTSE)_20200706
State of North Carolina Department of Environmental Quality DWR Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resaurces FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: A UL) kLl—r (to be completed by DWR) All items must be completed or the application will be returned ILA �`v ' —` d I. APPLICANT INFORMATION: 1. Applicant's name: Town of Pittsboro (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Federal ❑ State/County ® Municipal 3. Signature authority's name: John Poteat per 15A NCAC 02T .0106(b) Title: Public Works & Utilities Director 4. Applicant's mailing address: PO Box 759, 480 Hillsbor2St._5uite 400 City: Pittsboro State: NC ,Zip: 273 t2- 5. Applicant's contact information: Phone number: 9( I9) f42-2530 Email Address: iRoteat(iDgittsboronc.com II. PROJECT INFORMATION: I1 � ❑ Privately -Owned Public Utility ❑ Other l I. Project name: Thales Academe - Chatham Park 2. Application/Project status: ® Proposed (hew Permit) ❑ Existing Permit/Projcct If a modification, provide the existing permit number. WQ00_ and issued date: If new construction but part of a master plan, provide the existing permit number: WQ00389848 3. County where project is located: Chatham 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.722623' Longitude:-79.159688' 5. Parcel ID (if applicable): 93773 (or Parcel ID to closest downstream sewer) lll. CONSULTANT INFORMATION: 1. Professional Engineer: Ross Massey License Number; 19779 Firm: STEWART, Inc Mailing address: 223 S. West St.. Suite 1100 City: Ra_ leish State: NC ,Zip: 27603- Phone number: (2_L9) 380-8750 Email Address: rmassey(i—i stewartinc.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Town of Pittsboro WWTP Permit Number: NCO020354 Owner Name: Town of Pittsboro V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ0039848 Downstream (ReLeiving) Sewer Size: �8 inch System Wide Collection System Permit Number(s) (if applicable). WQCS.610' Owner Name(s): a FORM: FTA 04-16 Paee 1 of 5 VI. G>EMERAL REQUIREMENTS L If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No N/A 2. if the Applicant is a Developer of lots to be sold, has a Developer's O erational Agreement hOR� I-DEVI been attached.1 ❑ Yes ❑No QX NrA 3. if tine Applicant is a Home/property Owners' Association, has an O erational Agreement I FORM: 11OA been attached? []Yes ❑ No E)N,'A 4. Origin of %vastewater. (check all that apply): ❑ Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Nash ❑ Residential Leased ❑ Retail with food preparatiorL!Serviee ❑ Hotel and. or Motels © School / preschool I day care ❑ Nledical' dental / veterinary facilities ❑ Swimming Pool Clubhouse ❑ Food and drink facilities ❑ Church ❑ Switttrnittg I'oolTilter Bat:k%t ash ❑ Businesses / offices factories ❑ Nursing Home ❑ Other (Lxplain in Attachment) 5. Nature of wastewater: 140 °'� DomesticiCommercial % Commercia: °/� Industrial {See 15A `CAC OZI .0103(2011 � b is there a Pretreattiient Prograni in effect" ❑ Yes ❑ Na 6. Hasa flow reduction been approved under 15A NCAC 02T ;01 1411)? []Ye.; 0 do i If %es trovide a en of Ilo►v reduction a royal letter 7. Summarize wastewater generated by project: Establishment Type (see 112'[ U1141ti) Daily Design 1Flow4J, Schools without cal56, gym or shower No. of Units Flow 10 gallstudent 600 6,000 GPD GPD gal! GPD g3I' GPD aal I GPD gall I GPD w Tvrat J 6,000 GPD a See I5A NCAC 02T .0114(b). (d),(c)(1) and (6(?) for carats to wastewater design flow rates (i.e., minimum now per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A4). b Per 15A NCAC 02T .0114(c), design no"- rates for e.,tablrshtncnis not identified [in table 15A NCAC 02T.01 141 shall be determined using available flow data, water using fixtures, occupancy (rr operation patterns, and other measured data. 8- Wastewater generated by project: 6.000 GPD (per 15A N('AC 02'l' .Ql 14) Do not inelude future flows or previously permitted allocations If permitted flow is zero, Indicate wliy ❑ l'unip Station or Gravity Sewer when flay in be permitted in subsequent permits that conncet to this line ❑ How has already been allocated in Pcrniil Number: -- ❑ Rehabilitation or replacement of existing sewer n ith no new Elena ctp4ctcd ❑ Other (Explain): mane. L'rA ni it VII. GRAVITY SENVER DESIGN CRITERIA (If Applicable) - 02T .0305 & NIDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Sire (inches) Length (feet) Material 8" 381 PVC R" 189 DIP 5 �D ➢ Section II & ill of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section Ill contains information related to minimum slopes for gravity sewer(s) Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC Vill. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Puml2 StationslForce I♦iains : COMPLETE FOR EACH PUMP STATION LNCLUDED Pi THIS PROJECT 1. Pump station number or name: NIA 2. Approximate Coordinates (Decimal Degrees): Latitude: ° Longitude: 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the puntp(s): gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with I SA NCAC 02T .0305(h)(1)-. ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(H)". Y Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day i• Must he permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): y It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. rr%roM I. r ♦ n4 1i -. - 0- IX. SETBACKS & SEP:U2ATIONS — (02B .0200 & 15A NCAC 02T .0305(f)): 1. Does the project comply with all separations found in 1 i.A NCAC 02T .0305 4C ) ®Yes ❑\To L 15A NCAC 02T-030iff) contains nr.nimuni separations that shall be provided for sewer S�stenis: r Se aration Rc uired �T Setback Parameter' 24 inches Storm sewers and other utilities not listed below (vertical) _ 18 inches__ ~ Watcr mains (vertical -water over sewer includini: in benched trenches) Water mains (horizontal) 10 feet _ (reclaimed water lines (vertical - reclaimed over ~ewer) _ _ _ IS inchas 2 feet Reclaimed water lines (horizontal - reclaimed over server) ««Any private or public water supply source, including any welis, WS-I %Va-ers of Class I or Class it ininoundcd reservoirs used as a source of drinkina water w_ 100 feet **Waters classified WS (except WS-I or WS-V ), B, SA, ORW, f IQW, or SB from normal Itielt water (or tide elevation) and wetlands (_.,we item IX 2) 50 feet **Anv other stream, lake, impoundment. or around water lowerin, and surf tcc drainage {ditches -- — In feet 5 feet Anv buibuildinL, foundation _ " -- _ __- Anv basement 10 (feel ~ T 'rop slope of embankment or cuts of 2 feet or more vertical lie ielit 10 feet Drainag s; stems and interceplor drains _ _ _ i Ieet 10 feet Am swirnntin_ pools Final earth _rade tvertical) — 36 inches 1 iAN CAC 02T.0305(g) contain; alterna rives wher: -eQpuratiuns in 02T.0305cannot be achieved *'Strearn classifications can be identified usinu the Division's NC Surface Water C lassit_lcatiam,_wehPai r If nonevniphant.e wilh 02T.0305(f) or (2), see SCCli011 N Ot' 1110 application 2. Dues the project tioinply with separation requirement: for wetlandi" (50 feet of separation) ❑ Yes ❑ No ED NrA See the Division's draft separation requirements for :ituatjons where separation cannot he niect v No variance is required if the alternative design criteria sp,:dFied is titii zed in dcsiOn and von orixlion As built documents should reference the location of areas effecter! 3. Does the project Comply with setbacks found in the river basin rules per I i.a NCAC 0213.0200' ❑ 5'cs ❑ No Q N A i This would include Trout Buffered Strcams per I5A NCAC' 2B.0202 4. Does the project require coverage/authorization under a 404 Nationwide or ElYes [INo individual peirnits or 401 Water Quality C.crtifications? Infotniation can he obtained from the 401 fi Buffer Perniittint Branch 5. hoes project comply with 15A NCAC 021'.010i(c}f6) (additicnal permit; -certifications)'.' © Yes [:]No 11er 15A NCAC 02T.0105(c)t6 , directly rehited ent imiuuental permits or certification dpplications are being prepared, leave been app;ied for, or have been obtained. lsstiam-e of this permit iS crn_tintent on issuance of dependent penuits (erosion and sedimen'ation control plans. stormwater maital,,ement plans, etc.). 6. Does this project include any server collection line; that are deenied "hi_h-pn.%rily?" Per 15A NCAC 02T.0402. "high -priority xen er" means "any aerial server, sewer contactwo surface waters, siphon, or sewer positioned parallel to streambattks that is Subject to erosion that undermines or deteriorates the sewer. ❑ Yes El No ❑ N-A Y If yes, include an attachment with details for eaJ: line, including type (aerial line, size. material- and location). High priority lines shall be inspected by the perntittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's indit idual System -Wide Collection permit. X. CERTIFICATIONS: 1. Does the submitted system comply with 5A NCAC 02T, die Minimum Desi&ri Criiena fgr the Pennitting_qf PiL V Lotions and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version( as applicable? ® Yes ❑ No If No, complete and submit the Variance,'Alternative Design Request application (VADC 10-14) and supporting documents for review. Appruval of the re nest is res ulred prior to submittal of the Fast Track Application and suavortln2 documents. 2. Professional Engineer's Certification; 1, C t R-P-55- A-114 S s� _ _T _ _ _ _attest that this application for (Professional Engineer's name frJm Application Item has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to die best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE - In accordance with General Statutes 143-215.6A and 143-215.65, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed S 10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per 15A NCAC 021' .0106(bi: 0111 1rr,,i .` , COI ���� Z �� 4 s ti � 4,r %osS attest that this application for (Signature Authority's name & title from Application Item 1.3.) has been reviewed by nie and is accurate :Ind complete to the best of my knowledge, I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package arc not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: Date:���� FORM - FTA 04-16 Paste 5 of 5 NC Dept of Environmental Quality i STEWART JUL - 6 2020 Raleigh Regional Offjce State of North Carolina Department of Environmental Quality Division of Water Resources Fast Track Application - Part B Cover Letter & Project Narrative TO: NCDEQ Water Resources - Sewer Permitting FROM: C. Ross Massey, PE RE: Thales Academy - Chatham Park DATE: June 1, 2020 Existing Site Information The project site is located along Vine Parkway within the Chatham Park development site. The site's existing condition is undeveloped woodlands ~- and is park of the Chatham Park Development Project. This project does not impact any existing wetlands and is not known to be within any Water Supply Watersheds. The latest version of the United States Department of Agriculture Soil Conservation Service Soil Survey of Orange County, North Carolina map indicates that the on -site soils are predominantly Georgeville Silt Loam & Nanford Badin which is classified as Hydrologic Soil Group B. Per FEMA Flood Insurance Rate Map 37109751003, dated February 2, 2007 the project is within Zone X and no 100-yr Floodplain is present, but the 500-year flood elevation does impact the southern portion of the site. Proposed Site Improvements Proposed development on the site will include the clearing of existing woodlands and all other site features within the new project footprint. Once demolition of the existing site has occurred, a 3-story elementary school building will be constructed. Accessible sidewalks, parking lot, green space and on site bioretention area trail will be provided to allow for access in and around the site. Existing sewer leaves the proposed building traversing north to southwest and is collected at Vine Parkway. Additionally, the proposed water is looped around the site starting from the northern drive aisle and ending at the southern drive aisle along Vine Parkway. Utility improvements include the addition of an 8" sewer to be tied into an existing system & an 8" waterline loop onsite tying into an existing water main at two point. SMOW.F'R TIN p 104.% 223 S WEST ST RALEIGH, NC T 919 3110.R750 SUITE 1100 27603 F 919 3801752 0 N tn 0 cn 0 0 0 0 0 Ln 0 0 0 0 0 c n n M G r c3;$3 A $3 Elln cw°0M CG7 m flA m� MGM 37"�no m'm3 y c3�n a xx a m :r mrz ��1 22�y M � , n C m 7� a Z� 3� 3 3 Y! Yl :mO 9.1 I�A aT IS m8� i 11it g o a s m rt m I �I i I Ir $ 1 Fi 3 Res, 3,m,�N�� 4�• :aa �' � � m'0 am g3G►+w Q EL 3 m „ y w a G s c n 1 m g r4 ° a° M c c $n�n$ ;oA n 3� $mO a �3° D,e '^i'n $ aiLlmw 3�$A�a ¢sue m1�J m m m w c m °" 3 0 m 3; 3 w m A m 3 r u z$ m s m m m m3E$m_ e"ig01"'i" °1st $ $ $ '� �xOR $�mm n3�� �o ap3° ?nm m m m 3 eo m w y �$ m m m c m 3 5EL ic S 9 IL EL 4 m iTj 1 m zpgOm 0 0 Q 2 N Q r CD I 0 m m a 1JJ17S 41't. O&AWtr[Nt OF M[ MTERM u.s ccaawua kwnrcr w,..� , ;: U$ TOpO" NTSt6alla QUAD WAC •�` Id j T 1� 1j .`.�"-�� �- � Illy � _ i ' V r kk1 y W^S wr.MAu.lYwr¢ww G.wT•wlr.n ..I WALE 1:1 O[U _�. .a. n,.wr•b. 6l19rQundS Ru _Cm m ` CD Julean -_ n -Beck St to _75or -� w ,1 I q} 'r r� v � rep Rd LETTER OF TRANSMITTAL i STEWART TO Jason Robinson NCDEQ - Sewer 1628 Mail Service Center Raleigh, NC 27699 OATS SENT VIA 2020.06.30 UPS Ground FROM Colle Crosby, EI I STEWART 223 S. West St., Suite 1100 Raleigh, NC 27603 PROJECT NUMBER PROJECT NAME L19031 Thales Academy at Chatham Park - PWSS Permit Set NC Dept of Environmental Quality COPIES DATE DESCRIPTION 1 06 30 20 Fast Track Application & Cover JUI- 1 Aerial Map Offic Firm MaioCli:i �gfc�t3�� 1 1 480 Fee For approval For review & comment Returned For corrections For your use Approved as submitted Returned after review As requested Approved as noted Resubmit copies for approval COMMENTS If you have any questions or concerns, please let me know. SIGN olie Crosby, EI COPIED TO Cashion, Ted / From: Ross Massey <rmassey@stewartinc.com> Sent: Tuesday, August 25, 2020 1:26 PM To: Cashion, Ted Cc: Robinson, Jason; Colie Crosby Subject: RE: [External) RE: Thaler Academy - Chatham Park fast track sewer extension permit application, WQ0041808 lixternal email. Do not elicit links or open attachments unless you verify. Send all suspiciouemail aarr attadhment toll ;reaort.stsam 2nc.pov y..., �. Ted, Thanks for sharing. I reviewed the requirements below and am confirming that our sewer services connect to induvial buildings and then connect at public sewer manholes. We are consistent with the rules stated below. Thanks, Ross Ross Massey, PE Studio Leader, Civil Engineering Direct 919.866.4781 Mobile 919.369.5435 STEWART STRONGER BY DESIGN From: Cashion, Ted <ted.cashion@ncdenr.gov> Sent: Tuesday, August 25, 202012:32 PM To: Ross Massey <rmassey@stewartinc.com> Cc: Robinson, Jason <jason.t.robinson@ncdenr.gov> Subject: RE: [External] RE: Thales Academy w Chatham Park fast track sewer extension permit application, WQ0041808 Hi Ross, One more question for you. Can you confirm the 6" service lines comply with the reg below? This has come up on previous projects and has turned into problems. Just trying to avoid issues. Thx ted 1:5A `CAC 02T ,0303 PER-%ff G BY REGULATION (a) The following systems shall be deemed permitted pursuant to Rule .0113 of this Subchapter if the system meets the criteria in Rule .0113 of this Subchapter and all criteria required for that system in taus Rule: (t) a building sewer documented by the local building inspector to be in compliance vnth the North Carolina State Pltimbuig Code and that sen-es a single building with the sole purpose of conveying wastewater from that building into a gravity sewer that extends onto or is adjacent to the butldings property- A building seaaer that contributes more di i. fire percent of the existing wastewater treatment facihrVs design capacity or 50-000 gallons per day of flow as calculated rising the wastewater design flow rates in Rite 011.1 of this Subchapter shall not commence operations unto a letter of agreement, meeting the requirements of 15A NC AC 02T-0304(g). has been submitted to and approved by the regional office: (?} a gravity server serving a single building with less than 600 gallons per day of flow as calculated using rates in 15A NCAC 02T 0114 that crosses another property or parallels a ngltt-of-way, provided that. (A) an easement for crossing another property is obtained- a map is created, and both are recorded at the Register of Deeds office nil the county of residence for both property owners and nuns v6th the land or. in the case of a building sewer traveling along a right- of-way, documented permission from the dedicated righr-of way owner to use such right - of n ay; 71 (B) the building inspector certifies the sewer to the point of connection to the existing sels-er is in accordance with state or local plumbing code; and (C) no other connections are made to the sewer -without prior approval front the Division: Ted Cashion Water Quality Regional Operations Division of Water Resources NC Department of Environmental Quality Raleigh Regional Office 919-791-4254 ted.cashiony2ncclunr.gov 1628 Mail Service Center Raleigh, NC 27699-1628 3800 Barrett Drive Raleigh, NC 27609 vu//� , v L�5 6 ` Y/ Cashion. Ted From: Ross Massey <rmassey@stewartinc.com> Sent: Tuesday, August 25, 2020 1:01 PM To: Cashion, Ted Cc: Robinson, Jason; Colie Crosby; Christopher J. Miller Subject: RE: [External] RE: Thales Academy - Chatham Park fast track sewer extension permit application, WQ0041808 External email. Do not slick links or open attachments unless you verify. Send all suspicious email as an attachment to� .mport.sua,r 0)nc_gov Ted, We'll review and confirm. Thanks, Ross Ross Massey, PE Studio Leader, Civil Engineering Direct 919.866.4781 Mobile 919.369,5435 STEWART STRONGER BY DESIGN From: Cashion, Ted <ted.cashion@ncdenr.gov> Sent: Tuesday, August 25, 202012:32 PM To: Ross Massey <rmassey@stewartinc.com> Cc: Robinson, Jason <jason.t.robinson@ncdenr.gov> Subject: RE: [External] RE: Thales Academy - Chatham Park fast track sewer extension permit application, WQ0041808 Hi Ross, One more question for you. Can you confirm the 6" service lines comply with the reg below? This has come up on previous projects and has turned into problems. Just trying to avoid issues. Thx ted 1 Cashion, Ted From: Cashion, Ted Sent: Tuesday, August 25, 2020 11:46 AM To: Colie Crosby, Ross Massey, Robert Morgan; John Poteat Cc: Robinson, Jason; Deck, Erin M; Jim Nass; Jeff Jones; Christopher J. Miller, ckennedy@pittsboronc.gov Subject: RE: [External] RE: Thales Academy - Chatham Park fast track sewer extension permit application, WQ0041808 Just to confirm the info on the updated application sent yesterday: The original permit application included the following: 6" 158 linear feet PVC 8" 381 linear feet PVC 8" 189 linear feet DIP The updated application included the following: 8" 381 linear feet PVC 8" 189 linear feet DIP Does the project need to include the 158 linear feet of sewer line? If so, the size of the pipe must be a minimum 8" since it's a "public" line (owned by Pittsboro). If the 158 linear feet is needed and is to remain a "private" line (private ownership), it's acceptable to leave the line as a 6" line, but we'll need an application and fee to permit the construction and operation of this line. Please advise. Thx ted Ted Cashion Water Quality Regional Operations Division of Water Resources NC Department of Environmental Quality Raleigh Regional Office 919-791-4254 ted.cashion@ncdenr.gov 1628 Mail Service Center Raleigh, NC 27699-1628 3800 Barrett Drive Raleigh, NC 27609 1 Cewr�t ai [n:ronnensu Qw �� Subscribe to Collection System & Sewer Permitting Updates Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties unless the content is exempt by statute or other regulation. Based on the current guidance to minimize the spread of COV1D-19, DEQ has adjusted operations to protect the health and safety of the staff and public. Many employees are working remotely or are on staggered shifts. To accomodate these staffing changes, all DEQ office locations are limiting public access to appointments only. Please check with the appropriate staff before visiting our offices, as we maybe able to handle your requests by phone or email. We appreciate your patience as we continue to serve the public during this challenging time. From: Colie Crosby <ccrosby@stewartinc.com> Sent: Monday, August 24, 2020 3:49 PM To: Ross Massey <rmassey@stewartinc.com>; Cashion, Ted <ted.cashion@ncdenr.gov>; Robert Morgan <rmorgan@pittsboronc.gov>; John Poteat <jpoteat@pittsboron c.gov> Cc: Robinson, Jason <jason.t.robinson@ncdenr.gov>; Deck, Erin M <erin.deck@ncdenr.gov>; Jim Nass <jnass@pittsboronc.gov>; Jeff Jones <jjones@pittsboronc.gov>; Christopher J. Miller <cmiller@stewartinc.com> Subject: Re: [External] RE: Thales Academy - Chatham Park fast track sewer extension permit application, WQ0041808 i • External email. Do not click4inks or ope �.n?porl.spam n attachments unless you verify. Send all suspicious email as an attachment to ' Wne.2ov Ted, Please see the updated application, attached. Please let me know if there is anything else you need. Thank you! Colie Crosby Jr. Engineering Intern, Civil Engineering STEWART STRONGER BY DESIGN Direct 919.866,4796 Office 919.380.8750 223 S. West Street, Suite 1100, Raleigh, NC 2-7603 Visit us aty.-yim stewartinc.com Cashion, Ted From: Ross Massey <rmassey@stewartinc.com> Sent: Monday, August 24, 2020 6:02 AM To: Cashion, Ted; Robert Morgan; John Poteat Cc: Robinson, Jason; Deck, Erin M; Jim Nass; Jeff Jones; Colie Crosby; Christopher J. Miller Subject: RE: [External] RE: Thales Academy - Chatham Park fast track sewer extension permit application, WQ0041808 • External email. Do not click links or open attachdrents unless you verify. Send all suspicious email as an attadlim nt to irenort.scam,�nc.�ov .. Ted, Apologies for not responding sooner. We'll coordinate providing the updated application. Thanks, Ross Ross Massey, PE Studio Leader, Civil Engineering STEWART STRONGER BY DESIGN Direct 919.866.4781 Office 919.380.8750 Mobile 919.369.5435 223 S. West Street, Suite 1100, Raleigh, NC 27603 Visit us at www.stewartinc.com 2019 �000 BEST PLACES TO WORK From: Cashion, Ted <ted.cashion@ncdenr.gov> Sent: Saturday, August 22, 202011:50 AM To: Robert Morgan <rmorgan@pittsboronc.gov>; John Poteat <jpoteat@pittsboronc.gov>; Ross Massey <rmassey@stewartinc.com> Cc; Robinson, Jason <jason.t.robinson@ncdenr.gov>; Deck, Erin M <erin.deck@ncdenr.gov>; Jim Nass <jnass@pittsboronc.gov>; Jeff Jones <jjones@pittsboronc.gov> Subject: RE: [External] RE: Thales Academy - Chatham Park fast track sewer extension permit application, WQ0041808 This is the 311 email request for this project. We need a revised item VII.1 of the application showing the 6" line replaced with an 8" line. A 6" line is in violation of the Division's Minimum Design Criteria for public sewer lines. The minimum size for a public sewer line is 8". Please respond in the next few days. Failure to respond may result in the application being returned to you. Ted Cashion Water Quality Regional Operations Division of Water Resources NC Department of Environmental Quality Raleigh Regional Office 919-791-4254 ted.cashion_@ncdenr.gov 1628 Mail Service Center Raleigh, NC 27699-1628 3800 Barrett Drive Raleigh, NC 27609 tr- D�E Cepiri;k of frrvroie nuf fYu4 Subscribe to Collection System & Sewer Permitting Updates Email correspondence to and frjrn this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties unless the content is exempt by statute or other regulation. Based on the current guidance to minimize the spread of COVID-19, DEQ has adjusted operations to protect the health and safety of the staff and public. Many employees are working remotely or are on staggered shifts. To accomodate these staffing changes, all DEQ office locations are limiting public access to appointments only. Please check with the appropriate staff before visiting our offices, as we maybe able to handle your requests by phone or email. We appreciate your patience as we continue to serve the public during this challenging time. From: Cashion, Ted Sent: Saturday, August 8, 2020 7:46 AM To: Robert Morgan <rmoreanPpittsboronc.eov>; John Poteat <ipoteat2pittsboronc.Rov>; rmassey@stewarti_nc.com Cc: Robinson, Jason <iason.t.robinson2ncdenr.eov>; Deck, Erin M <erin.deck ncdenr. ov>; Jim Nass <inass@pittsboronc.eov>; Jeff Jones <iiones@a pittsboronc.gov> Subject: RE: [External] RE: Thales Academy - Chatham Park fast track sewer extension permit application, WQ0041808 Thanks Bob. As noted in previous emails, we need a revised item VII.1 of the application showing the 6" line is to be replaced with an 8" line. We'll continue drafting the permit upon submittal and review of this info. Ted Cashion Water Quality Regional Operations Division of Water Resources NC Department of Environmental Quality Raleigh Regional Office 919-791-4254 ted.cashion@ncdenr.gov 1628 Mail Service Center Cashion, Ted From: Colie Crosby <ccrosby@stewartinc.com> Sent: Monday, August 24, 2020 3:49 PM To: Ross Massey; Cashion, Ted; Robert Morgan; John Poteat Cc: Robinson, Jason; Deck, Erin M; Jim Nass; Jeff Jones; Christopher J. Miller Subject: Re: [External] RE: Thales Academy - Chatham Park fast track sewer extension permit application, WQ0041808 Attachments: CP-2019-07 Divisionof Water Resources Fast Track Sewer System Extension Application_ 2020.06.01 pdf.pdf External emaih-Do not -click links or open attadhments unless,you verify. Send all suspicious email as an attachment to Ted, Please see the updated application, attached. Please let me know if there is anything else you need. Thank you! Colie Crosby Jr. Engineering Intern, Civil Engineering STEWART STRONGER BY DESIGN Direct 919.866.4796 Office 919.380.8750 223 S. West Street, Suite 1100, Raleigh, NC 27603 Visit us at www.stewartinc.com 2019 BEST PLACES TO WORK From: Ross Massey <rmassey@stewartinc.com> Sent: Monday, August 24, 2020 6:01 AM To: Cashion, Ted <ted.cashion@ncdenr.gov>; Robert Morgan <rmorgan@pittsboronc.gov>; John Poteat <jpoteat@pittsboronc.gov> Cc: Robinson, Jason <jason.t.robinson@ncdenr.gov>; Deck, Erin M <erin.deck@ncdenr.gov>; Jim Nass <jnass@pittsboronc.gov>; Jeff Jones <jjones@pittsboronc.gov>; Colie Crosby <ccrosby@stewartinc.com>; Christopher J. Miller <cmiller@stewartinc.com> Subject: RE: [External] RE: Thales Academy - Chatham Park fast track sewer extension permit application, WQ0041808 Ted, Apologies for not responding sooner. We'll coordinate providing the updated application. Thanks, Ross Ross Massey, PE Studio Leader, Civil Engineering .TEVIART STRONGER BY DESIGN Direct 919.866.4781 Office 919.380.8750 Mobile 919.369.5435 223 S. West Street, Suite 1100, Raleigh, NC 27603 Visit us at www.stewartinc.com -2019 BEST PLACES TO WORK From: Cashion, Ted <ted.cashion@ncdenr.gov> Sent: Saturday, August 22, 2020 11:50 AM To: Robert Morgan <rmorgan@pittsboronc.gov>; John Poteat <jpoteat@pittsboronc.gov>; Ross Massey <rmassey@stewartinc.com> Cc: Robinson, Jason <jason.t.robinson@ncdenr.gov>; Deck, Erin M <erin.deck@ncdenr.gov>; Jim Nass <jnass@pittsboronc.gov>; Jeff Jones <jjones@pittsboronc.gov> Subject: RE: [External] RE: Thales Academy - Chatham Park fast track sewer extension permit application, WQ0041808 This is the V email request for this project. We need a revised item VITA of the application showing the 6" line replaced with an 8" line. A 6" line is in violation of the Division's Minimum Design Criteria for public sewer lines. The minimum size for a public sewer line is 8". Please respond in the next few days. Failure to respond may result in the application being returned to you. Ted Cashion Water Quality Regional Operations Division of Water Resources NC Department of Environmental Quality Raleigh Regional Office 919-791-4254 ted.cashion(@ncdenrgov 1628 Mail Service Center Raleigh, NC 27699-1628 3800 Barrett Drive Raleigh, NC 27609 �A/koo q(�Or t ] Cashion, Ted From: Cashion, Ted Sent: Saturday, August 22, 2020 11:50 AM !t To: Robert Morgan; John Poteat; rmassey@stewarti Icom Cc: Robinson, Jason; Deck, Erin M; Jim Nass; Jeff Jones Subject: RE: [External] RE: Thales Academy - Chatham Park fast track sewer extension permit application, W00041808 This is the 3d email request for this project. We need a revised item V11.1 of the application showing the 6" line replaced with an 8" line. A 6" line is in violation of the Division's Minimum Design Criteria for public sewer lines. The minimum size for a public sewer line is 8". Please respond in the next few days. Failure to respond may result in the application being returned to you. Ted Cashion Water Quality Regional Operations Division of Water Resources NC Department of Environmental Quality Raleigh Regional Office 919-791-4254 ted.cashion@ncdenr.gov 1628 Mail Service Center Raleigh, NC 27699-1628 3800 Barrett Drive Raleigh, NC 27609 E Subscribe to Collection System & Sewer Permitting Updates Email correspondence to and from this address may be subject to the North Carolina Public Records Low and may be disclosed to third parties unless the content is exempt by statute or other regulation. Based on the current guidance to minimize the spread of COVID-19, DEQ has adjusted operations to protect the health and safety of the staff and public. Many employees are working remotely or are on staggered shifts. 7o accomodate these staffing changes, all DEQ office locations are limiting public access to appointments only. Please check with the appropriate stoff before visiting our offices, as we may be able to handle your requests by phone or email. We appreciate your patience as we continue to serve the public during this challenging time. From: Cashion, Ted Sent: Saturday, August 8, 2020 7:46 AM To: Robert Morgan <rmorgan@pittsboronc.gov>; John Poteat <jpoteat@pittsboronc.gov>; rmassey@stewartinc.com Cc: Robinson, Jason <jason.t.robinson@ncdenr.gov>; Deck, Erin M <erin.deck@ncdenr.gov>; Jim Nass <jnass@pittsboronc.gov>; Jeff Jones <jjones@pittsboronc.gov> Subject: RE: [External] RE: Thales Academy - Chatham Park fast track sewer extension permit application, WQ0041808 Thanks Bob. As noted in previous emails, we need a revised item V1 1.1 of the application showing the 6" line is to be replaced with an 8" line. We'll continue draft;ng the permit upon submittal and review of this info. Ted Cashion Water Quality Regional Operations Division of Water Resources NC Department of Environmental Quality Raleigh Regional Office 919-791-4254 ted.cashion ncdenr. ov 1628 Mail Service Center Raleigh, NC 27699-1628 3800 Barrett Drive Raleigh, NC 27609 GWrAwK of InrlPhnKaLl pu kt� Subscribe to Collection S stem & Sewer P ermitting Updates Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties unless the content is exempt by statute or other regulation. Based on the current guidance to minimize the spread of COVID-19, DEQ has adjusted operations to protect the health and safety of the staff and public. Many employeLbs are working remotely or are on staggered shifts. To occomodate these staffing changes, all DEQ office locations are limiting public access to appointments only. Please check with the appropriate staff before visiting our offices, as we may be able to handle your requests by phone or email. We appreciate your patience as we continue to serve the public during this challenging time. From: Robert Morgan [mailto.rmorgan@ ip ttsboronc.eov] Sent: Monday, August 3, 2020 9:37 AM To: Cashion, Ted <ted.cash'on ncdenr. ov>; John Poteat < oteat ittsboronc. ov>; rmasse stewartinc.com Cc: Robinson, Jason <'ason.t.rabinson ncdenr. ov>; Deck, Erin M <erin.deck ncdenr. ov>; Jim Nass <jnass@pittsboronc.eov>; Jeff Jones <"ones ittsboronc. ov> Subject: [External] RE: Thales Academy - Chatham Park fast track sewer extension permit application, WQ0041808 11*111" External email. Do not click links or open attachments unless re ort-s anc. ov you verify. Send all suspicious email as an attachment to -- i The Town of Pittsboro concurs with the revision to an eight inch wastewater line. The Town's plant Will treat the wastewater. Bob Morgan Interim Town Manager From: Cashion, Ted <ted.cashion ncdenr. ov> Sent: Saturday, August 1, 20201:00 PM To: John Poteat < oteat ittsboronc. ov>; rmasse stewartinc.com Cc: Robinson, Jason <'asi on.t._robinson@ncdenr.eov>; Deck, Erin M <erin.deck(@ncdenr.sov>; Robert Morgan <rmorean(@pittsboronc.sov>; Jim Nass <inass@ Pittsboron c. ov> Subject: RE: Thales Academy - Chatham Park fast track sewer extension permit application, WQ0041808 We have not received a response to the email below. Also, the narrative states this project is part of the Chatham Park Development Project. Will the wastewater from this project be tributary to and be treated in the Chatham Park WWTP? The application notes the receiving WWTP is Pittsboro. Please confirm which is the receiving WWTP. Ted Cashion Water Quality Regional Operations Division of Water Resources NC Department of Environmental Quality Raleigh Regional Office 919-791-4254 ted.cashion6Dncdenr.eov 1628 Mail Service Center Raleigh, NC 27699-1628 3800 Barrett Drive Raleigh, NC 27609 0,EQ ` D►puMrni M [meara+snhl 4ftYSY� Subscribe to Collection System & Sewer Permitting Updates Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties unless the content is exempt by statute or other regulation. Based on the current guidance to minimize the spread of COV1D-19, DEQ has adjusted operotions to protect the health and safety of the staff and public. Many employees are working remotely or are on staggered shifts. To accomodate these staffing changes, all DEQ office locations are limiting public access to appointments only. Please check with the appropriate staff before visiting our offices, as we may be able to handle your requests by phone or email. We appreciate your patience as we continue to serve the public during this challenging time. From: Cashion, Ted Sent: Tuesday, July 14, 2020 10:34 AM TO: 'jpoteat@pittsboronc.gov'<ipoteatepittsboronc.gov>; rmasse stewartinc.com Cc: Robinson, Jason <iason.t.robinson@ncdenr.eov>; Deck, Erin M <erin.deckC@ncdenr.eov> Subject: Thales Academy - Chatham Park fast track sewer extension permit application, WQ0041808 We received the subject application 7-6-20. A cursory review of the application showed a 6" diameter gravity sewer is included in the application, The 6" diameter gravity sewer design is in violation of the 2T rules and Minimum Design Criteria for Gravity Sewers: 15A NCAC 02T .0305 Design Criteria (iJ The following criteria shall be met for gravity sewers: (1) public gravity sewers shall be equipped with a minimum eight inch diameter pipe.... MDC III. Details of Design and Construction A. Minimum Size No public gravity sewer conveying wastewater shall be less than 8 inches in diameter. Please revise the design of the gravity sewer to be 8" minimum and submit a revised item V11.1 of the application showing the revision. We'll also need confirmation from the Town agreeing with the revision. An email verifying approval of the revision is sufficient. We'll review the application in more detail after this revision is submitted. Ted Cashion Water Quality Regional Operations Division of Water Resources NC Department of Environmental Quality Raleigh Regional Office 919-791-4254 ted.cashion@ncdenr.gov 1628 Mail Service Center Raleigh, NC 27699-1628 3800 Barrett Drive Raleigh, NC 27609 z:5;,,D,- EJ w (}Ipt+;+enl �! (mrplenlrtLtl Ltira4S} Subscribe to Collection System & Sewer Permitting updates Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties unless the content is exempt by statute or other regulation. Cashion Ted oT -4 �:U f Sn0"�L From: Cashion, Ted Sent: Saturday, August 8, 2020 7:46 AM To: Robert Morgan; John Poteat; rmassey@stewartinc.com Cc: Robinson, Jason; Deck, Erin M; Jim Nass; Jeff Jones Subject: RE: [External] RE: Thales Academy - Chatham Park fast track sewer extension permit application, WQ0041808 Thanks Bob. As noted in previous emails, we need a revised item VII.1 of the application showing the 6" line is to be replaced with an 8" line. We'll continue drafting the permit upon submittal and review of this info. Ted Cashion Water Quality Regional Operations Division of Water Resources NC Department of Environmental Quality Raleigh Regional Office 919-791-4254 ted.cash ion C&ncdenr.go_v 1628 Mail Service Center Raleigh, NC 27699-1628 3800 Barrett Drive Raleigh, NC 27609 DEr f -Tw�ul Ov �± !�f Subscribe to Collection System & Sewer Permitting Updates Email correspondence to and from this address may be subject to the North Carolina Public Records Low and may be disclosed to third parties unless the content is exempt by statute or other regulation. Based on the current guidance to minimize the spread of COV1D-19, DEQ has adjusted operations to protect the health and safety of the staff and public. Many employees are working remotely or are on staggered shifts. To accomodate these staffing changes, all DEQ office locations are limiting public access to appointments only. Please check with the appropriate staff before visiting our offices, as we may be able to handle your requests by phone or email. We appreciate your patience as we continue to serve the public during this challenging time. From: Robert Morgan[mailto:rmorgan@pittsboronc.gov] Sent: Monday, August 3, 2020 9:37 AM To: Cashion, Ted <ted.cashion@ncdenr.gov>; John Poteat <jpoteat@pittsboronc.gov>; rmassey@stewartinc.com Cc: Robinson, Jason <jason.t.robinson@ncdenr.gov>; Deck, Erin M <erin.deck@ncdenr.gov>; Jim Nass <jnass@pittsboronc.gov>; Jeff Jones <jjones@pittsboronc.gov> Subject: [External] RE: Thales Academy - Chatham Park fast track sewer extension permit application, WQ0041808 nts unless you;verify. 5end.all suspicions email as.6k� The Town of Pittsboro concurs with the revision to an eight inch wastewater line. The Town's plant will treat the wastewater. Bob Morgan Interim Town Manager From: Cashion, Ted <ted.cashion@ncdenr.eov> Sent: Saturday, August 1, 2020 1:00 PM To: John Poteat <' oteat ittsboronc. ov>; rmassey@stewartinc.com Cc: Robinson, Jason <'asonA.robinson ncdenr. ov>; Deck, Erin M <erin.deck@ncdenr,eov>; Robert Morgan <rmor an ittsboronc. ov>;1im Nass <jnass ittsboronc.eov> Subject: RE: Thales Academy - Chatham Park fast track sewer extension permit application, WQ0041808 We have not received a response to the email below. Also, the narrative states this project is part of the Chatham Park Development Project. Will the wastewater from this project be tributary to and be treated in the Chatham Park WWTP? The application notes the receiving WWTP is Pittsboro. Please confirm which is the receiving WWTP. Ted Cashion Water Quality Regional Operations Division of Water Resources NC Department of Environmental Quality Raleigh Regional Office 919-791-4254 ted.cashion ncdenr. ov 1628 Mail Service Center Raleigh, NC 27699-1628 3800 Barrett Drive Raleigh, NC 27609 Subscribe to Collection System & Sewer Permitting Updates Email correspondence to and from this address may be subject to the North Carolina Public Records low and may be disclosed to third parties unless the content is exempt by statute or other reg{nation, Based on the current guidance to minimize the spread of CQV1D-19, DEQ has adjusted operations to protect the health and safety of the staff and public. Many employees are working remotely or are on staggered shifts. To accomodate these staffing changes, all DEQ office locations are limiting public access to appointments only. Please check with the �V�%� s Cashion, Ted From: Robert Morgan <rmorgan@pittsboronc.gov> I Sent: Monday, August 3, 2020 9:37 AM ( �� To: Cashion, Ted; John Poteat; rmassey@stewartinc.com Cc: Robinson, Jason; Deck, Erin M; Jim Nass; Jeff Jones Subject: [External] RE: Thales Academy - Chatham Park fast track sewer extension permit application, WQ0041808 -ice sib+�es� excernai emau. Do not cklck�lms or oped attzahrhents unless.you verify. Sena all suspicious ernall as an atta-finient The Town of Pittsboro concurs with the revision to an eight inch wastewater line. The Town's plant will treat the wastewater. Bob Morgan Interim Town Manager From: Cashion, Ted <ted.cashion@ncdenr.gov> Sent: Saturday, August 1, 20201:00 PM To: John Poteat <jpoteat@pittsboronc.gov>; rmassey@stewartinc.com Cc: Robinson, Jason <jason.t.robinson@ncdenr.gov>; Deck, Erin M <erin.deck@ncdenr.gov>; Robert Morgan <rmorgan@pittsboronc.gov>; Jim Nass <jnass@pittsboronc.gov> Subject: RE: Thales Academy - Chatham Park fast track sewer extension permit application, WQ0041808 We have not received a response to the email below. Also, the narrative states this project is part of the Chatham Park Development Project. Will the wastewater from this project be tributary to and be treated in the Chatham Park WWTP? The application notes the receiving WWTP is Pittsboro. Please confirm which is the receiving WWTP. Ted Cashion Water Quality Regional Operations Division of Water Resources NC Department of Environmental Quality Raleigh Regional Office 919-791-4254 ted.cashion@ ncdenr.eov 1628 Mail Service Center Raleigh, NC 27699-1628 3800 Barrett Drive Raleigh, NC 27609 Subscribe to Collection System & Sewer Permitting Up dates Email correspondence to and from this address may be subject to the North Carolina Public Records Low and may be disclosed to third parties unless the content is exempt by statute or other regulation. Based on the current guidance to minimize the spread of COVID-19, DEQ has adjusted operations to protect the health and safety of the staff and public. Many employees are working remotely or are on staggered shifts. To accomodote these staffing changes, all DEQ office locations are limiting public access to appointments only. Please check with the appropriate staff before visiting our offices, as we may be able to handle your requests by phone or email. We appreciate your patience as we continue to serve the public during this challenging time. From: Cashion, Ted Sent: Tuesday, July 14, 2020 10:34 AM To* 'jpoteat@pittsboronc.gov'<ipoteatPoittsboronc.goy>; rmassey@stewartinc.com Cc: Robinson, Jason <'ason.t.robinson ncdenr. ov>; Deck, Erin M <erin.deck@ncdenr.eov> Subject: Thales Academy - Chatham Park fast track sewer extension permit application, WQ0041808 We received the subject application 7-6-20. A cursory review of the application showed a 6" diameter gravity sewer is included in the application. The 6" diameter gravity sewer design is in violation of the 2T rules and Minimum Design Criteria for Gravity Sewers: 15A NCAC 02T .0305 Design Criteria (i) The following criteria shall be met for gravity sewers: (1) Public gravity sewers shall be equipped with a minimum eight inch diameter pipe.— MDC 111. Details of Design and Construction A. Minimum Size No public gravity sewer conveying wastewater shall be less than 8 inches in diameter. Please revise the design of the gravity sewer to be 8" minimum and submit a revised item V11.1 of the application showing the revision. We'll also need confirmation from the Town agreeing with the revision. An email verifying approval of the revision is sufficient. We'll review the application in more detail after this revision is submitted. Ted Cashion Water Quality Regional Operations Division of Water Resources Cashion, Ted From: Cashion, Ted Sent: Saturday, August 1, 2020 1:00 PM To: jpoteat@pittsboronc.gov; rmassey@stewartinc.com Cc: Robinson, Jason; Deck, Erin M; rmorgan@pittsboronc.govjnass@pittsboronc.gov Subject: RE: Thales Academy - Chatham Park fast track sewer extension permit application, WQ0041808 We have not received a response to the email below Also, the narrative states this project is part of the Chatham Park Development Project. Will the wastewater from this project be tributary to and be treated in the Chatham Park WWTP? The application notes the receiving WWTP is Pittsboro. Please confirm which is the receiving WWTP. Ted Cashion Water Quality Regional Operations Division of Water Resources NC Department of Environmental Quality Raleigh Regional Office 919-791-4254 ted.cashion@ncdenr.eov 1628 Mail Service Center Raleigh, NC 27699-1628 3800 Barrett Drive Raleigh, NC 27609 �D E l ?lps+=mr.! et f n,rteawn'rt L4sa's'r�% Subscribe to Collection System & Sewer Permittinq Updates Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties unless the content is exempt by statute or other regulation. Based on the current guidance to minimize the spread of COVID-19, DEQ has adjusted operations to protect the health and safety of the staff and public. Many employees are working remotely or are on staggered shifts. To accomodate these staffing changes, all DEQ office locations are limiting public access to appointments only. Please check with the appropriate staff before visiting our offices, as we may be able to handle your requests by phone or email. We appreciate your patience as we continue to serve the public during this challenging time. From: Cashion, Ted Sent: Tuesday, July 14, 202010:34 AM To:'jpoteat@pittsboronc.gov' <jpoteat@pittsboronc.gov>; rmassey@stewartinc.com Cc: Robinson, Jason <jason.t.robinson@ncdenr.gov>; Deck, Erin M <erin.deck@ncdenr.gov> Subject: Thales Academy - Chatham Park fast track sewer extension permit application, WQ0041808 We received the subject application 7-6-20. A cursory review of the application showed a 6" diameter gravity sewer is included in the application. The 6" diameter gravity sewer design is in violation of the 2T rules and Minimum Design Criteria for Gravity Sewers: 15A NCAC 02T .0305 Design Criteria (i) The following criteria shall be met for gravity sewers: (1) public gravity sewers shall be equipped with a minimum eight inch diameter pipe.... MDC ill. Details of Design and Construction A. Minimum Size No public gravity sewer conveying wastewater shall be less than 8 inches in diameter. Please revise the design of the gravity sewer to be 8" minimum and submit a revised item VII.1 of the application showing the revision. We'll also need confirmation from the Town agreeing with the revision. An email verifying approval of the revision is sufficient. We'll review the application in more detail after this revision is submitted. Ted Cashion Water Quality Regional Operations Division of Water Resources NC Department of Environmental Quality Raleigh Regional Office 919-791-4254 ted.cashion(@ncdenr.gov 1628 Mail Service Center Raleigh, NC 27699-1628 3800 Barrett Drive Raleigh, NC 27609 Subscribe to Collection System & Sewer Permitting Updates Cashion, Ted From: Cashion, Ted Sent: Tuesday, July 14, 2020 10:34 AM To: 'jpoteat@pittsboronc.gov; rmassey@stewartinc.com Cc: Robinson, Jason; Deck, Erin M Subject: Thales Academy - Chatham Park fast track sewer extension permit application, WQ0041808 We received the subject application 7-6-20. A cursory review of the application showed a 6" diameter gravity sewer is included in the application. The 6" diameter gravity sewer design is in violation of the 2T rules and Minimum Design Criteria for Gravity Sewers: 15A NCAC 02T .0305 Design Criteria (i) The following criteria shall be met for gravity sewers, (1 ) public gravity sewers shall be equipped with a minimum eight inch diameter pipe.... MDC III. Details of Design and Construction A. Minimum Size No public gravity sewer conveying wastewater shall be less than 8 inches in diameter. Please revise the design of the gravity sewer to be 8" minimum and submit a revised item V11.1 of the application showing the revision. We'll also need confirmation from the Town agreeing with the revision. An email verifying approval of the revision is sufficient. We'll review the application in more detail after this revision is submitted. Ted Cashion Water Quality Regional Operations Division of Water Resources NC Department of Environmental Quality Raleigh Regional Office 919-791-4254 ted.cashion ncdenr. ov 1628 Mail Service Center Raleigh, NC 27699-1628 3800 Barrett Drive Raleigh, NC 27609 \, e-r DEMon Subscribe to Collection System & Sewer Perm-itting Updates Email correspondence to and from this address may be subject to the North Carolina Public Records Low and may be disclosed to third parties unless the content is exempt by statute or other regulation.