Loading...
HomeMy WebLinkAboutNC0024406_Compliance Evaluation Inspection_20200831ROY COOPER Governor MICHAEL S. REGAN Secretary S. DANIEL SMITH Director NORTH CAROLINA Environmental Quality August 31, 2020 Duke Energy Carolinas LLC Attn: Reginald D. Anderson, Station Manager 3195 Pine Hall Rd. Belews Creek, NC 27009 SUBJECT: Compliance Inspection Report Belews Creek Steam Station NPDES WW Permit No. NCO024406 Stokes County Dear Mr. Anderson: Shuying Wang, the NC Division of Water Resources (DWR), Winston-Salem Regional Office (WSRO), visited the Belews Creek Steam Station on August 26, 2020 to perform Compliance Evaluation Inspection. The inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0024406. The assistance and cooperation of Brenda Johnson, Barry Jones, and other relevant staff are greatly appreciated. Details of the inspection are recorded on the attached EPA Water Compliance Inspection Report. There were no significant issues noted during the inspection and therefore, a response to this inspection report is not required. If you have any questions, please contact Shuying Wang at 336-776-9702, or by email at shuying.wang@ncdenr.gov. You may also contact me by phone at 336-776-9700, or by email at lon.snider@ncdenr.gov. Sincerely, D"ocu.Signeed' by. 0 p3 F,3FI 456... Lon m er, Regional Supervisor Water Quality Regional Operations Section Winston-Salem Regional Office Division of Water Resources, NCDEQ Attachments: EPA Water Compliance Inspection Report for Duke Energy Belews Creek Steam Station cc: LaserFiche Joyce Dishmon, Brenda Johnson, Barry Jones, Brendon Burgess, Duke Energy (E-copy only) �INAfl North Carolina Department of Environmental Quality 1 Division of Water Resources Winston-Salem Regional Office 1 450 West Hanes Mill Road, Suite 300 1 Winston-Salem, North Carolina 27105 A0kIHC �pp.adme��af Emnonma�� nuai� �� 336,776,9800 United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 15 I 3 I NC0024406 I11 121 20/08/26 I17 18 n 19 L G j 201 21111111111111111111111111111111111111111111 f6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 CA ---------------------- Reserved ------------------- 67 70 L�a J � 71 I tyI 72 L Ln, � 73 LLI74 71 I I I I I I I80 J Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 09:OOAM 20/08/26 19/04/01 Belews Creek Steam Station Pine Hall Rd Exit Time/Date Permit Expiration Date Walnut Cove NC 27052 11:35PM 20/08/26 24/02/29 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data ///Brenda Johnson, Senior Environmental Professional, 336-445-0634, Brenda.Johnson2@duke-energy.com, Joyce Dishmon, Permitting and Complinace, Carolinas, Barry Jones, ORC, Brendon Burgess, and others Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Reginald D Anderson,3195 Pine Hall Rd Belews Creek NC 27009/Station Manager -GM No III Regulated Station/336-445-0501/ Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Flow Measurement 0 Operations & Maintenar 0 Records/Reports Self -Monitoring Progran 0 Sludge Handling Dispos 0 Pollution Prevention 0 Facility Site Review Compliance Schedules 0 Effluent/Receiving Wate 0 Laboratory 0 Storm Water Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Shuying Wang DWR/WSRO GW/336-776-9702/ DocuSigned by: �� 8/27/2020 E 068A33DC2E91408_._ Signature of Management Q A Revie Docusigned by: Agency/Office/Phone and Fax Numbers Date ,'a. %J� 8/28/2020 �M-t' 7456 EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type 31 NCO024406 I11 12I 20/08/26 117 18 U Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Ash basin looks different from the last routine inspection. Decanting was almost done. The facility was clean and well maintained. Major components of the treatment system were inspected and were in operation and well maintained. No discrepancies from the permit were noted. Outfalls 001, 005 and 006, and internal outfalls,002, 003A, and 006A, were inspected. Effluent waters or receiving waters at outfalls were free of foam other than trace amount noted at 001. Page# Permit: NCO024406 Owner - Facility: Belews Creek Steam Station Inspection Date: 08/26/2020 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ 0 ❑ application? Is the facility as described in the permit? 0 ❑ ❑ ❑ # Are there any special conditions for the permit? 0 ❑ ❑ ❑ Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? 0 ❑ ❑ ❑ Comment: Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ 0 ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Compliance Schedules Yes No NA NE Is there a compliance schedule for this facility? 0 ❑ ❑ ❑ Is the facility compliant with the permit and conditions for the review period? 0 ❑ ❑ ❑ Comment: Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? 0 ❑ ❑ ❑ Is all required information readily available, complete and current? 0 ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? 0 ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? 0 ❑ ❑ ❑ Is the chain -of -custody complete? 0 ❑ ❑ ❑ Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ ❑ Page# 3 Permit: NCO024406 Owner - Facility: Belews Creek Steam Station Inspection Date: 08/26/2020 Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operatc ❑ ❑ 0 ❑ on each shift? Is the ORC visitation log available and current? 0 ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? 0 ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility classification' 0 ❑ ❑ ❑ Is a copy of the current NPDES permit available on site? 0 ❑ ❑ ❑ Facility has copy of previous year's Annual Report on file for review? ❑ ❑ 0 ❑ Comment: Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? 0 ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? 0 ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ 0 ❑ Comment: Flow Measurement - Influent Yes No NA NE # Is flow meter used for reporting? ❑ 0 ❑ ❑ Is flow meter calibrated annually? ❑ ❑ 0 ❑ Is the flow meter operational? ❑ ❑ 0 ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ 0 ❑ Comment: Calculated based on pumping rate and time. Lagoons Yes No NA NE Type of lagoons? Facultative # Number of lagoons in operation at time of visit? 1 Are lagoons operated in? # Is a re -circulation line present? ❑ ❑ 0 ❑ Is lagoon free of excessive floating materials? 0 ❑ ❑ ❑ # Are baffles between ponds or effluent baffles adjustable? ❑ ❑ 0 ❑ Are dike slopes clear of woody vegetation? 0 ❑ ❑ ❑ Are weeds controlled around the edge of the lagoon? 0 ❑ ❑ ❑ Are dikes free of seepage? ❑ 0 ❑ ❑ Are dikes free of erosion? 0 ❑ ❑ ❑ Are dikes free of burrowing animals? 0 ❑ ❑ ❑ Page# 4 Permit: NCO024406 Owner - Facility: Belews Creek Steam Station Inspection Date: 08/26/2020 Inspection Type: Compliance Evaluation Lagoons Yes No NA NE # Has the sludge blanket in the lagoon (s) been measured periodically in multiple ❑ ❑ 0 ❑ locations? # If excessive algae is present, has barley straw been used to help control the growth? ❑ ❑ 0 ❑ Is the lagoon surface free of weeds? ❑ ❑ 0 ❑ Is the lagoon free of short circuiting? ❑ ❑ 0 ❑ Comment: There was very little water in the ash basin. Decanting was almost completed. Seeps were not noted. In addition to the Ash basin, the domestic wastewater treatment lagoon was stopped by. Currently there is no discharge. Wastewater has been handled with a Pump and Haul permit. Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ❑ ❑ 0 ❑ Is sample collected below all treatment units? ❑ ❑ 0 ❑ Is proper volume collected? 0 ❑ ❑ ❑ Is the tubing clean? ❑ ❑ 0 ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees 0 ❑ ❑ ❑ Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type 0 ❑ ❑ ❑ representative)? Comment: Upstream / Downstream Sampling Yes No NA NE Is the facility sampling performed as required by the permit (frequency, sampling type, an( 0 ❑ ❑ ❑ sampling location)? Comment: Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? 0 ❑ ❑ ❑ Is flow meter calibrated annually? 0 ❑ ❑ ❑ Is the flow meter operational? 0 ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ 0 ❑ Comment: There were five flow meters: one at each of outfalls 003A, 006 and 006A and two at the decantinq water treatment unit. Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? 0 ❑ ❑ ❑ Page# 5 Permit: NCO024406 Inspection Date: 08/26/2020 Owner - Facility: Belews Creek Steam Station Inspection Type: Compliance Evaluation Laboratory Are all other parameters(excluding field parameters) performed by a certified lab? # Is the facility using a contract lab? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? Comment: Yes No NA NE ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ Page# 6