Loading...
HomeMy WebLinkAbout20201086 Ver 1_D6i_U5026_R5720_HYD_PRM_WET_FULL_SET_08_21_2020_20200825CX3080192.09EL*5215 CX3079BL*5215 CX3030EL*5215 CX3029BL*5215 CONC CONC CONC CONCCONC CONC CONC R/W MON R/W MON R/W MON R/W MON R/W MON R/W MON R/W MON R/W MON R/W MON R/W MON R/W MON R/W MON R/W MON R/W MONR/W MON R/W MON R/W MON R/W MON R/W MON ;;;;;;;;;;;;;;; ; ; ;; ;;;;;;;;CONC18' 54" RCPINV.=175.92'INV.=175.01'8" CMP 8" CMP 8" CMP 8" CMP INV.OUT=178.97' (W)INV.=161.35'INV.=170.02'18" CMPEND NOT FOUND END NOT FOUND END NOT FOUND END NOT FOUND END NOT FOUND CONC ISLAND INV.=UNKNOWN INV.=UNKNOWN INV.=194.91' INV.=194.96' MONR/W R/W MON MTL MTL MTL MTL MTL MTL MTL MTL MTL CABLE MTL CABLEMTL MTL MTL MTL MTLMTL MTL MTLCABLE CABLE 175.92 149.69149.43 105.67 104.09 APPROX 159.07159.06158.62158.77158.93 159.08159.10 159.25159.31 159.23159.31 159.53159.49 159.85159.86 160.42160.34 160.88160.87 161.61161.60 162.61162.58 163.66163.65 165.00165.06 166.20166.16 168.48168.38168.39168.15168.48168.41 163.00162.98 162.74162.71162.68 162.70162.66 162.84162.83 162.85162.90 163.03163.06 163.31163.33 163.42163.46 163.73163.70 164.21164.20 164.56164.47 164.89164.95 165.43165.44 166.66166.67 169.01169.26 164.60164.72 164.49164.45 164.28164.29 164.12164.08 164.09164.18 163.81163.76163.75163.74 163.72163.68 163.79163.77 163.88163.98 163.85163.96 163.81163.89 163.82163.74 163.86163.82 164.11164.02 164.20164.24 164.47164.41 164.60164.70 165.06165.06 165.34165.31 165.77165.92 166.36166.33 166.65166.72 167.80167.63167.86167.91 167.51167.68 164.87164.93 163.36163.48 161.68 160.55160.55 159.68159.65 159.05158.99 158.38158.27 157.56157.73157.73 156.85156.84 156.37156.42 156.17156.07 155.66155.67155.30155.38155.05155.00154.50154.44154.04154.00153.72153.64153.82153.85 144.04143.85 154.25 154.69154.68 155.22155.13 155.62155.85155.86 156.53156.51 157.43157.42 176.59 147.32147.06 146.48 150.99150.92 150.41150.48 149.36149.44 145.82145.85 142.43142.29 137.85137.99 132.73132.59 125.68126.14 170.02 10316 162.20 162.55 12282132.8612284132.84 12291131.9512293131.89 12296130.8912298130.86 12301130.0712303130.0612306129.5312308129.3412309129.32 12310130.40 12313129.2112316129.42 12318128.6712321128.63 12323127.7212326127.69 12329124.5412332124.92 12335120.6212338120.75 12341118.3012344118.47 12347116.3712350116.56 12353114.6712356114.98 12359111.3312362 12365109.4812368109.44 12371108.2012374108.49 12398108.3512401107.96 12404106.2812407106.38 12410105.5812413105.4912415105.0312418105.26 12419104.47 12436130.54 12439131.4912440131.40 12443130.7012445130.7112446130.79 12449129.7412451129.75 12456128.3312458128.44 12459127.5912468127.5912469132.8712470133.4312471133.47 12472132.79 12473132.7012474132.7012475132.8612476127.57 12487126.5512489126.56 12490125.1112492125.10 12498122.0512500122.08 12503118.2812505118.14 12507116.6512509116.8712510116.88 12535114.0312536114.0312538114.47 12540108.4912542108.2912545107.8112547107.1812551107.71 12552107.67 12554106.0512558106.2612559105.9812564106.0512565107.0612566105.8612567104.9112568105.0312569105.76 13165165.6513166165.6513168165.1013169165.55 13172165.0313173164.87 13174165.6013176165.72 13177166.2813179166.24 13180166.8013182166.76 13183167.6213185167.60 13186167.9513188167.96 13189168.80168.76 13192169.5713194169.54 13197170.5413198170.49 13200171.5613202171.61 13203172.6713205172.67 13206174.0713208174.17 13209175.13175.14 13212176.3113214176.20 13215177.1513217177.29 13218178.1713220178.15 13221179.1213223179.19 13224179.9513226179.91 13227180.8813229180.92 13230181.4413232181.41 13235181.5413236181.51 13237182.2113239182.14 13240183.0313242183.18 13243183.8913245183.78 13246184.4713248184.44 13249185.1813250184.7813252185.1713253185.17 13255167.02 13258167.2413259166.7113260167.27 13261167.07 13262173.19 13264173.4613265173.0013267173.40 13268173.13 13270173.1113272172.8313273173.10 13274172.7813276172.8013278172.8113279172.85 13280173.0913281172.6913283172.8113284172.81 13285171.2313286171.2313287170.9013289171.35 13291170.9213292171.13 13302171.1613303170.7313305171.2313306171.23 13308176.2713309175.8813310176.34 176.7313312176.3113314176.78 13316180.3113317179.9713318180.30 13319180.8913320180.4013322180.91 13324165.9913325165.5913327166.08 13329165.2513330164.9313331165.22 13332166.0413333165.5813335165.98 13337165.5213338165.2713339165.51 13340166.0013341165.5413343166.02 13345165.1913346164.8913347165.20 13348154.6313349154.1113351154.62 13353154.0713354153.7113355154.0613356155.0513357154.5813359155.06 13361154.4413362154.0913363154.4013364154.5513365154.1313367154.54 13369154.1013370153.7713371154.19 13372149.4613373148.9713375149.42 13378149.1013379149.11 13380149.4513381148.9913383149.44 13384149.1413385149.15 13389150.2313390149.5713391149.39 13393150.30 13395150.60 13398151.21 13399152.0813400151.6113402152.03 13403151.3013404150.5813405150.16 13406152.2913407151.7513409152.23 13410151.87 13413152.2213414151.7813416152.29 13417151.96 13418158.6013419158.2113421158.64 13423158.23 13425159.2113426158.7913428159.26 13431146.9713432146.6513434146.94 13435146.7013438146.73 13439146.6713440146.3213442146.7613443146.6113444146.71 13445147.4813446147.0113448147.39 13450147.0113451146.7713452147.14 13453147.6813454147.1813456147.57 13458147.3313459147.1913460147.28 13461147.6813462147.1613464147.65 13466147.0113467146.5813468147.00 13469148.8813470148.4113472148.92 13475148.6413476148.9613477148.3913479148.92 13480148.4613481148.1913482148.42 13484148.4813485148.1013487148.36 13488148.3913490148.39 13492148.2013493148.19 13495148.6813497148.65 13498148.7313500148.72 13501149.0313503148.89 13504148.9313506148.98 13508148.9413510149.07 149.0213513148.81 13514148.9013516148.99 13517149.1813519149.17 13520149.1913522149.29 13523149.5413525149.43 13526149.5713528149.7313529149.5213530149.7713532149.8113533149.6913534149.5513535149.3613537149.6613538149.4413539149.4613540149.4113541149.42 13546151.1013547150.6313549151.09 13552151.1313553150.7413555151.27 13556151.0513557150.6913559151.20 13562150.58 13563151.3113564150.6713566151.0313567150.40 13569143.3313570142.8813572143.37 13574142.9413575142.5313576142.90 13577143.4613578143.1013580143.38 13582143.0313583142.7013584142.91 13585140.9213586140.5713588140.96 13591140.69 13592141.2013593140.9013595141.1313596140.79 13597141.0913598140.5813600141.1013601140.66 13604140.9213605140.4113607140.89 13608140.7513609141.3013610141.19140.4313614140.9313615140.4413617140.96 13619140.6313620140.2313621140.56 13622141.2813623140.8513625141.36 13627140.9913628140.6313629140.99 13630140.7113631140.2113633140.69 13635140.4313636140.1113637140.55 13640146.0313641145.6513643146.03 13644145.0313645145.4413646145.0013647144.6913648144.9013649144.70 13660143.9813662144.00 13663143.5013665143.45 13666142.6513668142.72 13669141.9713671141.92 13672141.5913674141.69 13675141.2913677141.2513678140.9913680141.0313681140.6813683140.6813684140.5513686140.55 13687140.4513688140.36 13691140.7613692140.4013695140.76 13696140.8013697140.3613699140.82 13701140.1313702139.8813703140.41 13706153.0513707153.0513709152.6513710153.20 152.2013713152.19 13714151.1613716151.21 13717150.4913719150.44 13720149.5813722149.66 13723148.9613725148.92 13726147.7113728147.76 13729146.7013731146.7513732147.42 13733146.5213734145.77 13738146.0513739145.6113741146.01 13743146.43 13746148.7813748148.94 13749150.5713751150.59 13752152.2413754152.23 13755153.9613757153.79 13758155.2613760155.25 13761156.9013763156.99 13764158.3413765157.8913767158.3613768158.36 13770137.0613771136.5513773137.05 13776136.6413777136.6513778136.2613779136.6513780136.67 13782136.9313783136.4413785136.96 13786136.8213787136.8413791136.9613792136.5313794136.99 13796136.7113797136.3113798136.69 13799137.2913800136.8613802137.31 13804136.7913805136.4213806136.71 13807137.0613808136.6713810137.09 13812136.6413813136.3513814136.67 13815135.3713816134.9113818135.32 13819134.6713821134.2213823134.76 13824135.3713825134.9313827135.43 13828135.1713829135.19 13851128.1413852127.6513854128.16 13856127.7913857127.3613858127.5613859128.2913860127.7613862128.19 13864127.7613865127.2913866127.6713867127.7413868127.2113870127.70 13872127.3413873126.9913874127.42 13876122.5013877122.0713879122.50 13882121.94 13883122.5613884122.1713886122.54 13887121.9913888122.5713889122.2113891122.66 13892122.40 13895122.6213896122.1813898122.69 13899122.42 13900123.7413901123.2313903123.74 13906122.88 13907123.5813908123.1213910123.35 123.26 13913127.5513914127.0113916127.65 13918127.1213919126.7413920127.15 13921130.0913923130.09 13924130.8113926130.77 13927131.9013929131.97 13930132.8313933132.9113934132.90 161.61 ARBOREXISTING 3-CABLE EXISTING MTL EXISTING MTL ARBOR 29' BST 24' BST BST BST 16' CONC EXISTING MTL CONC R/W MON R/W MON R/W MON R/W MON R/W MON R/W MON R/W MON R/W MON R/W MON R/W MONR/W MONR/W MONR/W MONR/W MONR/W MONR/W MONR/W MON R/W MON R/W MON R/W MON R/W MON R/W MONR/W MONR/W MON R/W MON R/W MON R/W MON R/W MON R/W MON R/W MON R/W MON R/W MON R/W MON R/W MON R/W MONR/W MONR/W MONR/W MONR/W MON ;;;;;;;;;;;;;; ; ; ; ; ; ; ; ;;;; ; ; ;;;;;;;;;;;;;;; ;;;;;;;;INV.IN=148.95' (N)INV.IN=148.95' (N)54" RCP 54" RCP INV.OUT=132.98' (N)INV.IN=133.17' (S)INV.IN=129.68' (S)54" RCP INV.OUT=129.02' (W)8" CMP8" CMPINV.IN=138.77' (SE)INV.IN=138.77' (SE)8" CMP8" CMPINV.=149.69'INV.=149.43'INV.IN=124.46' (E)INV.OUT=116.49' (NW)INV.=103.27'60" RCPINV.OUT=123.47' (E)24" CMP INV.=105.67'INV.=104.09'INV.OUT=117.92' (E)INV.OUT=118.35' (E)24" CMP INV.OUT=161.97' (S)INV.OUT=161.95' (S)8" CMP 8" CMP 8" CMP8" CMP INV.=144.04'INV.=143.85'24" CMP 18" CMPINV.OUT=161.23' (S)INV.OUT=161.13'INV.=146.48' INV.=146.21' INV.=147.32' INV.=147.06'INV.OUT=157.26' (NW)INV.OUT=157.33' (NW)=122.07'SEAT ELEV.=122.40'SEAT ELEV.=123.68'SEAT ELEV.=122.97'SEAT ELEV.=124.97'SEAT ELEV.=125.03'SEAT ELEV.=125.35'SEAT ELEV.=124.22'SEAT ELEV.CABLE CABLEMTL MTL CABLE MTL CABLE MTLMTLMTL 16' CONC ROADWAY CABLE10' PAVED SHOULDER 16' CONC ROADWAY MTL MTL MTL MTL MTL MTL CABLE MTLINV.=152.66' INV.=152.63' MTL MTL MTL MTL MTL MTL MTLMTL MTLMTL 16' CONC ROADWAY 10' PAVED SHOULDER 16' CONC ROADWAY 4' PAVED SHOULDER MTL 16' CONC ROADWAY BENT ELEV.=190.70'BENT ELEV.=190.73'=190.80'BENT ELEV.=190.23'BENT ELEV.=190.56'ELEV.BENT =189.95'ELEV.BENT BENT ELEV.=162.86' BENT ELEV.=163.52' BENT ELEV.=165.06' BENT ELEV.=164.10'BENT ELEV.=164.14'BENT ELEV.=165.76'BENT ELEV.= 165.97'BENT ELEV.=166.91' BENT ELEV.=165.47' BENT ELEV.=164.83' BENT ELEV.=164.43' BENT ELEV.=165.12' BENT ELEV.=166.55'BENT ELEV.=165.40'BENT ELEV.=165.25'BENT ELEV.=163.23'BENT ELEV.=163.55'BENT ELEV.=164.63'BENT ELEV.=163.24' =163.08' ELEV.BENT vv CONC MON MON MON MON MON 74.16 LT-EL- 9+91.14 98.79 LT-EL- 12+42.56 75.51 LT-EL- 21+46.02 118.71 LT-EY1- 10+23.18 SR 1603 (OLD CARRIAGE RD) VARIABLE WIDTH BST MON MON 25A 33A STONY CREEK STONY CREEK STONY CREEK STONY CREEK STONY CREEK D T V = = = = = = % % MPH ADT ADT % * INCOMPLETE PLANS DO NOT USE FOR R/W ACQUISITION FUNC CLASS = K 0 0 0 PROFILE (HORIZONTAL) PROJECT LENGTH RIGHT OF WAY DATE: LETTING DATE: STATE STATE PROJECT REFERENCE NO. STATE PROJ. NO.F. A. PROJ. NO.DESCRIPTION NO. TOTAL SHEETS N.C. SHEET 1 DESIGN DATA SIGNATURE: SIGNATURE: P.E. P.E. PROJECT ENGINEER PROJECT DESIGN ENGINEER GRAPHIC SCALES PLANS PROFILE (VERTICAL) HYDRAULICS ENGINEER ENGINEER ROADWAY DESIGN09/08/99DIVISION OF HIGHWAYS STATE OF NORTH CAROLINA 0 00 ARTMEN N ASO H DEPT O F TRA SPORTTIONTATEOFNRTCAR O LI NA50 25 50 100 50 25 50 100 10 5 10 20 2040 (NOT TO SCALE) HDR Engineering, Inc. of the Carolinas N.C.B.E.L.S. License Number: F-0116 555 Fayetteville St, Suite 900 Raleigh, N.C. 27601 DIVISION OF HIGHWAYS 1000 Birch Ridge Dr., Raleigh NC, 27610 DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED CONTAINED IN THE REQUEST FOR PROPOSALS Prepared for the Office of: 2018 STANDARD SPECIFICATIONS See Sheet 1A-1 For Sheet Symbology TYPE OF WORK: N LOCATION: NAD 83/2011CONTACT: NCDOT CONST. 2019 CONTRACT:DESIGN-BUILD AS SPECIFIED IN THE SCOPE OF WORK P.E., R/W, UTIL.TIP PROJECT:Barnhill_Contracting_Corp\Barnhill-Rocky_Mount_DB\6.0_CAD_BIM\6.2_WIP\Hydraulics\PERMITS_Environmental\Drawings\U5026_R5720_HYD_PRM_WET_TSH.dgnCMYERS8/18/2020NCDOT_pdf_color_eng_100.plt3:01:27 PMNCDOT_TSH.tblPENTABLE:TIME:DATE:PLOT DRIVER:USER:FILE:NASH COUNTY 4 5 6 7 8 9 10 11 12 13 14 16 17 18 19 20 21 23 24 TO ROCKY MOUNTTO NASHVILLE (I-95) -L2- 58 58 INTERSTATE 95 INTERSTATE 95 (I-95) -L2- 15 TO WILSONTO US 64(RED OAK RD)-Y1-(REGENCY RD)-Y5-(FOREST VIEW DR)-Y4-(NCC ENTRANCE)-Y9-(EAST OLD SPRING RD) -Y7-(S EASTPOINTE AVE)-Y1A-(KALMAR RD)-Y6-(OLD CARRIAGE RD)-L1-(ARROW RD)-Y11-(WESTRY RD) -Y10-(FREIGHT RD)-Y15-10 60 3 50 * TTST = 1%DUAL = 2% URBAN ARTERIAL RURAL ARTERIAL & 17,311 26,100U-5026/ R-5720WARREN LAMB, PE PAUL ROBBINS, PE SR 1003 (RED OAK ROAD) TO SR 1544 (HALIFAX ROAD) SR 1770 (EASTERN AVENUE / SUNSET AVENUE) FROM U-5026 / R-5720 22 25 26 27 28 TO RED OAKOCTOBER 15, 2019 OCTOBER 15, 2019 (3RD ST)-Y16-(POPE ST)-Y17-44033.3.3 N/A -Y8-DIVISION PROJECT ENGINEER RACHEL EVANS, PE LENGTH ROADWAY -L1- (SR 1603) = 0.386 MILESC204412 LENGTH ROADWAY -L2SB- (I-95) = 2.349 MILES TOTAL LENGTH TIP PROJECT U-5026 / R-5720 = 6.632 MILES ROCKY MOUNT CITY OF NASHVILLE CITY OF (EASTERN AVE) -L- (SUNSET AVE) -L- CSX RR A PORTION OF THIS PROJECT IS LOCATED WITHIN THE MUNICIPAL BOUNDARIES OF THE TOWN OF NASHVILLE AND THE CITY OF ROCKY MOUNT. CLEARING ON THIS PROJECT SHALL BE PERFORMED TO THE LIMITS ESTABLISHED BY METHOD III, EXCEPT AS NOTED IN THE RFP. THIS IS A CONROLLED ACCESS PROJECT WITH ACCESS BEING LIMITED TO THE INTERCHANGE WITH I-95. NOTES: LENGTH ROADWAY -L- (SR 1770) = 2.426 MILES (R-5720) LENGTH ROADWAY -L- (SR 1770) = 1.414 MILES (U-5026) LENGTH STRUCTURES -L- (SR 1770) = 0.057 MILES (U-5026) SITE 9 SITE 13 SITE 14 SITE 15 SITE 16 SITE 16 SITE 7 SITE 6 SITE 6 SITE 5 SITE 2 SITE 3 SITE 4 SITE 1 SITE 10 SITE 11 SITE 8 SITE 12 08/18/2020 WETLAND AND SURFACE WATER IMPACTS U-5026 / R-5720 SITE 17 John Don Railroad Csx BEGIN PROJECT END PROJECT STRUCTURE SITE 1 BARNHILL CONTRACTING COMPANY VICINITY MAP PRELIMINARY ROADWAY PLANS64 64 BEGIN CONSTRUCTION -L1- STA. 10+33.86 BEGIN CONSTRUCTION -L2SB- STA. 4+21.78 -RAB1- -RAB2- -RAB3- -RAB4- -RAB5- -RAB6- -RAB7- END CONSTRUCTION -L2SB- STA. 128+25.99 BEGIN CONSTRUCTION -L- STA. 13+65.29 END CONSTRUCTION -L- STA. 224+39.02 END TIP PROJECT U-5026 -L- STA. 18+60.00 BEGIN TIP PROJECT R-5720 -L- STA. 146+71.78 BEGIN TIP PROJECT U-5026 END TIP PROJECT R-5720 -L1- POT STA. 30+70.01 BEGIN TIP PROJECT U-5996 BEGIN CONSTRUCTION -L1- POT STA. 30+70.00 END CONSTRUCTION SHEET __ OF __ PERMIT DRAWING CRCR SHEET __ OF __ PERMIT DRAWING ( Not to Scale) Geotextile BANK & SCOUR HOLE STABILIZATION Elevation Natural Bed STA. -L- 14+37 LT Ground Natural Ground Natural DETAIL 4-1 1.5' Flatter (TYP) 2:1 or Length= 30 Ft. (Variable) Channel Bed Existing Scour Hole Type of Liner= CL 'I' Rip-Rap - Keyed-In VARIESNOT TO SCALE 1:11:1COMPACTED BACKFILL AFLOW{FLOW { B B A TB TB 1'10'5' Min. SECTION A-A CHANNEL BLOCK SECTION B-B PLAN VIEW CHANNEL EXISTING BACKFILL BACKFILL COMPACTED BACKFILL UNCOMPACTED LENGTH MIN. #57 STONE MIN 1.0' DEPTH INVERT CHANNEL AS SPECIFIED IN PLANS SHALL BE TREATED NEW STREAMBANK BACKFILL UNCOMPACTED FINISH GRADE 1.5' CLASS I RIP-RAP,BACKFILL COMPACTED ( Not to Scale) Elevation Natural Bed Ground Natural Ground Natural Flatter (TYP) 2:1 or OUTLET PROTECTION 1.5' (var) Channel Bed DETAIL 6-3 DETAIL 6-4 2:12:1D ( Not to Scale) OUTLET CHANNEL PROTECTION B d Ground Natural Ground Natural Geotextile FROM -L- STA. 155+05 LT B= 5 Ft. Max. d= 4 Ft. Min. D= 4 Ft. DETAIL 15-1 ( Not to Scale) Geotextile Elevation Natural Bed Ground Natural Ground Natural 1.5' (var) Channel Bed Type of Liner= CL 'I' Rip-Rap - Keyed-In -CD2- STA. 46+20 RT DETAIL 23-1 ( Not to Scale) 3:13: 1 D B b LATERAL BASE DITCH 1"/Ft. FROM -CD2- STA. 46+20 TO STA. 48+20 RT DETAIL 23-2 b= 5 Ft. B= 4 Ft. Min. D= 2.5 Ft. Ground Natural Slope Fill HYDRAULICSROADWAY DESIGN ENGINEER ENGINEER R/W SHEET NO. SHEET NO.PROJECT REFERENCE NO. INCOMPLETE PLANS DO NOT USE FOR R/W ACQUISITION REVISIONS PENTABLE:FILE:Barnhill_Contracting_Corp\Barnhill-Rocky_Mount_DB\6.0_CAD_BIM\6.2_WIP\Hydraulics\PERMITS_Environmental\Drawings\U5026_HYD_ DETAILS.dgnUSER:CMYERSDATE:8/18/2020NCDOT_pdf_color_eng_100.pltPLOT DRIVER:12:03:58 PMTIME:NCDOT_TSH.tbl2D-1U-5026 /R-5720 DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED HDR Engineering, Inc. of the Carolinas N.C.B.E.L.S. License Number: F-0116 555 Fayetteville St, Suite 900 Raleigh, N.C. 27601 3: 1 b ( Not to Scale) D3:13:1 BERM 'V' DITCH FROM -LLPC- STA. 11+15 TO STA. 15+00 RT DETAIL 16-4 b=5 Ft. Min. D=1.5 Ft. Ground Natural RDWY B 3:13:1D ( Not to Scale) STANDARD BASE DITCH FROM -CD1- STA. 26+50 TO STA. 26+20 LT DETAIL 16-7 B= 2 Ft. Min. D= 1.5 Ft. Ground Natural Ground Natural ( Not to Scale) Elevation Natural Bed Ground Natural Flatter (TYP) 2:1 or (var) Channel Bed Type of Liner= CL 'I' Rip-Rap - Keyed-In3:1FROM -CD2- STA. 19+85 TO STA. 20+00 RT RIP RAP AT EMBANKMENT DETAIL 22-1 LATERAL 'V' DITCH ( Not to Scale) D 3:13:1 b 1"/Ft. FROM -CD1- STA. 14+80 TO STA. 15+78 LT b= 5 Ft. Min. D= 1.0 Ft. DETAIL 22-2 Ground Natural Slope Fill ( Not to Scale) 3:13:1D B b LATERAL BASE DITCH 1"/Ft. FROM -CD1- STA. 15+78 TO STA. 18+50 LT DETAIL 22-3 b= 5 Ft. B= 4 Ft. Min. D= 3.5 Ft. Ground Natural Slope Fill ( Not to Scale) 3:13:1D B b LATERAL BASE DITCH 1"/Ft. FROM -CD1- STA. 18+50 TO STA. 20+50 LT DETAIL 22-4 b= 5 Ft. B= 2 Ft. Min. D= 3.0 Ft. Ground Natural Slope Fill ( Not to Scale) 3:13:1D B FROM -CD1- STA. 20+50 TO STA. 25+00 LT DETAIL 22-5 b= 5 Ft. B= 2 Ft. Min. D= 2.5 Ft. Ground Natural Slope Fill FROM -CD2- STA. 18+50 TO STA. 20+00 RT Fill Slope2:1 or Flatter b= 5 Ft. d= 1 Ft. Type of Liner= CL 'B' Rip-Rap b DETAIL 22-6 Ground Natural ( Not to Scale) TOE PROTECTION d Geotextile ( Not to Scale) 3:13:1D B b SPECIAL CUT BASE DITCH 1"/Ft. FROM -LRPC- STA. 15+69 TO STA. 17+00 LT DETAIL 16-9 b= 5 Ft. B= 2 Ft. Min. D= 2.0 Ft. Ground Natural Slope Fill Flatter6:1 or D4:1( Not to Scale) SPECIAL CUT DITCH FROM -Y1- STA. 13+00 TO STA. 15+00 RT DETAIL 4-2 Min. D=1.5 Ft. Ground Natural Slope Ditch Front Flatter6:1 or D3: 1 ( Not to Scale) SPECIAL CUT DITCH FROM -L- STA. 110+50 TO STA. 113+13 LT DETAIL 11-2 Min. D=1.5 Ft. Ground Natural Slope Ditch Front B 3:13:1D ( Not to Scale) STANDARD BASE DITCH EST 160 CY EXCAVATION FROM -DRIVE1- STA. 11+05 TO STA. 18+50 RT DETAIL 11-4 B= 3' Ft. Min. D= 1.5' Ft. Ground Natural Ground Natural B 3:13:1D ( Not to Scale) STANDARD BASE DITCH EST 295 CY EXCAVATION FROM -L- STA. 61+15 RT (TAIL DITCH 495 LF) DETAIL 7-2 B= 4 Ft. Min. D= 2.0 Ft. Ground Natural Ground Natural 4:14: 1 SPECIAL BACK OF CURB CUT DITCH (NOT TO SCALE) FROM -L- STA. 134+00 TO STA. 135+70 LT DETAIL 13-1 GROUND NATURAL on banks only Geotextile Type of Liner= CL 'I' Rip-Rap - Keyed-In (on banks only) FROM STA. -L- 40+00 TO STA. 43+30 LT FROM STA. -L- 37+00 TO STA. 37+60 LT Fill Slope2:1 or Flatter b= 5 Ft. d= 1 Ft. Type of Liner= CL 'B' Rip-Rap b DETAIL 6-5 Ground Natural ( Not to Scale) TOE PROTECTION d Geotextile -L- STA. 40+50 LT -L- STA. 37+63 LT 0'-12'0'-5'7'-10' EXCAVATION THICKNESS = 2' W/ GEOTEXTILE (TYP) CLASS II RIP RAP 1' SILL NG NTS EST 40 CY EXCAVATION EST 65 SY GEOTEXTILE EST 60 TONS CL II RIP RAP CHANNEL DEPTH 2'-3' BEEN COMPLETE AT TIME OF THIS REPORT. SHOWN. FINAL WINGWALL DESIGN HAS NOT *NOTE: APPROXIMATE WINGWALL HEIGHTS ARE WINGWALL HEIGHT 4'-7' HEIGHT 5'-10' WINGWALL SPECIAL DESIGN -Y4- (3:1 NORMAL) PROPOSED FILL FROM -L- (3:1 NORMAL) PROPOSED FILL FROM 2:1(MAX.)2:1(MAX.) 4'-9'4'-7' 1' SILL NTS 2:1(MAX.)2:1(MAX.) CHANNEL DEPTH 2'-4' EXCAVATION THICKNESS = 2' W/ GEOTEXTILE (TYP) CLASS II RIP RAP NG 9'-10' EST 30 CY EXCAVATION EST 70 SY GEOTEXTILE EST 65 TONS CLASS II RIP RAP BACKFILL 1.0' MIN.) RIP RAP AND (FILL W/ CLASS I CHANNEL BLOCK AND CHANNEL BLOCK PROPOSED CHANNEL AND BACKFILL BETWEEN PLACE CLASS I RIP RAP CULVERT OUTLET DETAILCULVERT INLET DETAIL DETAIL 6-1 DETAIL 6-2 -L- STA. 41+09 RT -L- STA. 40+65 LT FROM -CD2- STA. 10+00 TO STA. 13+40 RT FROM -L2NB- STA. 14+20 TO STA. 15+19 RT FROM -CD1- STA. 11+00 TO STA. 12+20 LT FROM -L2SB- STA. 14+70 TO STA. 16+40 LT Fill Slope2:1 or Flatter b= 5 Ft. d= 1 Ft. Type of Liner= CL 'B' Rip-Rap b DETAIL 21-1 Ground Natural ( Not to Scale) TOE PROTECTION d Geotextile RIP RAP AT EMBANKMENT Flatter3:1 or D 3:1( Not to Scale) SPECIAL CUT DITCH FROM -LRPC- STA. 14+70 TO STA. 17+00 RT DETAIL 17-1 Min. D= 1.0 Ft. Ground Natural Slope Ditch Front Median Ditch ( Not to Scale) FALSE SUMP S S=Ditch Slope etc. GI L 2'DDDitch Grade L LDitch Grade 0.0% To 2.0% Over 2.0% To 4.0% 20' 30' Over 4.0% To 6.0% Over 6.0% 40' 50' 9" 20'L (See Chart Below) -CD1- STA. 18+80 RT DETAIL 21-2 C Proposed Ditch 3:1D B ( Not to Scale) Flatter3:1 or SPECIAL LATERAL BASE DITCH FROM -Y11- STA. 12+60 TO STA. 13+67 RT DETAIL 15-2 B= 2.0 Ft. Min. D= 1.5 Ft. Ground Natural Slope Fill B 3:13:1D ( Not to Scale) STANDARD BASE DITCH L=315 LF, SLOPE-0.16% EST 135 CY EXCAVATION FROM -L1- STA. 22+75 RT DETAIL 14-1 B= 2' Ft. Min. D= 1.5' Ft. Ground Natural Ground Natural ( Not to Scale) SPECIAL CUT DITCH 4:1D FROM -L- STA. 79+90 TO -L- STA. 82+00 LT Min. D=1.5 Ft. DETAIL 9-1 Ground Natural Flatter4:1 or Slope Fill ( Not to Scale) SPECIAL CUT DITCH 4:1D FROM -Y9- STA. 12+25 TO STA. 12+60 RT Min. D= 1.0 Ft. DETAIL 13-2 Ground Natural Flatter4:1 or Slope Fill ( Not to Scale) SPECIAL CUT DITCH 3:1D FROM -L- STA. 114+35 TO STA. 118+43 RT Min. D= 1.0 Ft. DETAIL 12-1 Ground Natural Flatter3:1 or Slope Fill ( Not to Scale) SPECIAL CUT DITCH 4:1D FROM -L- STA. 117+50 TO STA. 118+75 LT Min. D= 1.5 Ft. DETAIL 12-2 Ground Natural Flatter5:1 or Slope Fill ( Not to Scale) Geotextile BANK STABILIZATION Elevation Natural Bed Ground Natural Ground Natural DETAIL 16-3 Flatter (TYP) 2:1 or (Variable) Channel Bed Existing Scour Hole Type of Liner= CL I Rip-Rap - Keyed-In (ON BANKS ONLY) 1.5' -L- STA. 198+05 LT FROM STA. -L- 35+00 TO STA. 38+00 RT Fill Slope2:1 or Flatter b= 5 Ft. d= 1 Ft. Type of Liner= CL 'B' Rip-Rap b DETAIL 5-1 Ground Natural ( Not to Scale) TOE PROTECTION d Geotextile Flatter6:1 or D6:1( Not to Scale) SPECIAL CUT DITCH FROM -L- STA. 91+50 TO STA. 95+30 LT FROM -L- STA. 92+50 TO STA. 95+30 RT FROM -L- STA. 89+29 TO STA. 91+07 LT DETAIL 10-1 Min. D=1 Ft. Ground Natural Slope Ditch Front Median Ditch ( Not to Scale) FALSE SUMP S S=Ditch Slope etc. GI L 2'DDDitch Grade L LDitch Grade 0.0% To 2.0% Over 2.0% To 4.0% 20' 30' Over 4.0% To 6.0% Over 6.0% 40' 50' 9" 20'L (See Chart Below) --L2NB-- STA. 59+53 RT --L2NB-- STA. 53+40 LT --L2NB-- STA. 53+48 RT --L2NB-- STA. 51+90 RT DETAIL 23-3 C Proposed Ditch FROM STA. -L- 83+20 TO STA. 84+00 LT Fill Slope2:1 or Flatter b= 5 Ft. d= 1 Ft. Type of Liner= CL 'B' Rip-Rap b DETAIL 9-2 Ground Natural ( Not to Scale) TOE PROTECTION d Geotextile ( Not to Scale) SPECIAL CUT DITCH D Min. D=1 Ft. DETAIL 11-1 Ground Natural Flatter4:1 or Slope Fill Median Ditch ( Not to Scale) FALSE SUMP S S=Ditch Slope etc. GI L 2'DDDitch Grade L LDitch Grade 0.0% To 2.0% Over 2.0% To 4.0% 20' 30' Over 4.0% To 6.0% Over 6.0% 40' 50' 9" 20'L (See Chart Below) -L2SB- STA. 32+36 LT -L2NB- STA. 33+54 RT -L2NB- STA. 29+75 RT -L2NB- STA. 25+00 RT DETAIL 22-8 C Proposed Ditch FROM STA. -L- 157+80 TO STA. 159+44 RT Fill Slope2:1 or Flatter b= 5 Ft. d= 1 Ft. Type of Liner= CL 'B' Rip-Rap b DETAIL 15-3 Ground Natural ( Not to Scale) TOE PROTECTION d Geotextile ( Not to Scale) SPECIAL CUT DITCH 4:1D FROM -L- STA. 162+80 TO STA. 163+80 LT Min. D= 1 Ft. DETAIL 15-4 Ground Natural Flatter4:1 or Slope Fill FROM -L- STA. 38+00 TO STA. 40+00 RT DETAIL 6-7 BEHIND RETAINING WALL CONCRETE DITCH ~ SEIRAV D B 4" 1:2 ( Not to Scale) GROUND NATURAL WALL RETAINING BREAKER BOND B= 2.0' D= 1.0' 5' BERM SPECIAL CUT BASE BERM DITCH Flatter3:1 or D B ( Not to Scale) Flatter3:1 or SPECIAL CUT BASE DITCH FROM -CD2- STA. 19+80 TO STA. 30+50 RT DETAIL 22-7 B= 3.0 Ft. Min. D= 1.5 Ft. Ground Natural Slope Fill Type of Liner= CLASS 'II' Rip-Rap OF EXISTING CHANNEL MIN. OF 1 FT BEYOND INVERT EXTEND CHANNEL BLOCK THE ENGINEER. 6) COMPACT BACKFILL TO EXTENT POSSIBLE OR AT THE DIRECTION OF THE PROJECT SPECIFICATIONS IMMEDIATELY AFTER GRADING. 5) INSTALL EROSION CONTROL MATTING AND SEED IN ACCORDANCE WITH EXISTING STREAM CHANNEL. 4) BLOCK SHOULD EXTEND A MINIMUM OF 1 FT BEYOND THE LIMITS OF THE OF THE EXISTING CHANNEL. 3) BOTTOM OF BLOCK SHOULD BE A MINIMUM OF 1 FT BELOW THE INVERT CHANNEL AND PROPOSED CHANNEL. 2) BLOCK SHOULD BE INSTALLED AT THE INTERFACE BETWEEN EXISTING PROJECT SPECIFICATIONS. 1) CHANNEL BLOCK SHALL BE INSTALLED IN ACCORDANCE WITH THE NOTES:Flatter 3:1 or Flatter3:1 or DFlatter3: 1 or ( Not to Scale) SPECIAL CUT DITCH DETAIL 16-5 Min. D= 1.0 Ft. Ground Natural Slope Ditch Front Flatter6:1 or DFlatter4: 1 or ( Not to Scale) SPECIAL CUT DITCH FROM -L- STA. 57+85 TO STA. 61+20 LT FROM -L- STA. 53+00 TO STA. 55+00 LT FROM -L- STA. 55+50 TO STA. 57+50 RT DETAIL 7-1 Min. D=1.0 Ft. Ground Natural Slope Ditch Front Flatter6:1 or DFlatter4:1 or ( Not to Scale) SPECIAL CUT DITCH DETAIL 8-1 Min. D=1.0 Ft. Ground Natural Slope Ditch Front Min. D=3.0 Ft. D ( Not to Scale) SPECIAL CUT DITCH DETAIL 8-3 Ground Natural Slope Ditch Front 3:1 3:1FROM -L- STA. 74+50 TO STA. 77+15 LT OF EXISTING CHANNEL MIN. OF 1 FT BEYOND LIMITS EXTEND CHANNEL BLOCK Flatter3:1 or D3:1( Not to Scale) SPECIAL CUT DITCH FROM -L- STA. 89+30 TO STA. 95+30 LT DETAIL 10-2 Min. D=2.0 Ft. Ground Natural Slope Ditch Front 3:13:1 D ( Not to Scale) STANDARD 'V' DITCH FROM -L- STA. 194+53 TO STA. 194+57 RT Min. D= 1.5 Ft. DETAIL 16-10 Ground Natural Ground Natural B 3:13:1D ( Not to Scale) CHANNEL RELOCATION FROM -L- STA. 185+40 TO STA. 189+50 LT DETAIL 16-1 B= 5 Ft. Min. D= 2.0 Ft. Ground Natural Ground Natural B 3:13:1D ( Not to Scale) CHANNEL RELOCATION FROM -L- STA. 192+80 TO STA. 198+15 LT DETAIL 16-2 B= 5 Ft. Min. D= 2.5 Ft. Ground Natural Ground Natural Flatter4:1 or DFlatter3:1 or ( Not to Scale) SPECIAL CUT DITCH FROM -Y5- STA. 10+71 TO STA. 12+39 LT FROM -Y5- STA. 11+00 TO STA. 11+75 RT FROM -L- STA. 47+80 TO STA. 52+10 LT FROM -L- STA. 43+61 TO STA. 49+00 RT FROM -L- STA. 45+50 TO STA. 46+77 LT FROM -L- STA. 43+50 TO STA. 44+50 LT DETAIL 6-6 Min. D=1.0 Ft. Ground Natural Slope Ditch Front FROM -Y7- STA. 10+00 TO STA. 12+50 RT FROM -Y7- STA. 10+00 TO STA. 12+28 LT FROM -L- STA. 108+85 TO STA. -L- 110+50 RT FROM -L- STA. 105+50 TO STA. 110+50 LT FROM -L- STA. 105+50 TO STA. 107+55 RT ( Not to Scale) SPECIAL CUT DITCH D Min. D=1 Ft. DETAIL 12-3 Ground Natural Flatter4:1 or Slope Fill Flatter4:1 or FROM -L- STA. 115+00 TO STA. 116+00 LT Flatter4:1 or D3:1( Not to Scale) SPECIAL CUT DITCH FROM -CD2- STA. 31+50 TO STA. 35+00 RT FROM -CD1- STA. 26+50 TO STA. 29+00 LT FROM -CD1- STA. 24+90 TO STA. 26+50 LT DETAIL 16-6 Min. D= 1.5 Ft. Ground Natural Slope Ditch Front FROM -CD1- STA. 33+75 TO STA. 34+86 LT FROM -L- STA. 200+00 TO STA. 201+90 RT FROM -LLPC- STA. 12+88 TO STA. 14+50 LT FROM -LRPC- STA. 15+69 TO STA. 17+00 RT 3:1D Flatter3:1 or d ( Not to Scale) SPECIAL CUT DITCH FROM -CD1- STA. 34+86 TO STA. 36+00 LT FROM -LRPC- STA. 20+50 TO STA. 22+86 LT DETAIL 16-8 Max. d= 1.5 Ft. Min. D= 1.5 Ft. Type of Liner= CLASS B Rip-Rap Slope Ditch Front Ground Natural Geotextile ( Not to Scale) SPECIAL CUT DITCH D Min. D=1 Ft. DETAIL 10-3 Ground Natural Flatter4:1 or Slope Fill Flatter 3:1 or FROM -L- STA. 89+43 TO STA. 91+85 RT FROM -l- STA. 198+11 TO STA.198+37 LT Fill Slope2:1 or Flatter b= 5 Ft. d= 1 Ft. Type of Liner= CL 'B' Rip-Rap b DETAIL 16-11 Ground Natural ( Not to Scale) TOE PROTECTION d Geotextile FROM -L- STA. 62+80 TO STA. 64+25 RT B 3:13:1D ( Not to Scale) STANDARD BASE DITCH EST 295 CY EXCAVATION FROM -L- STA. 75+80 RT (TAIL DITCH 525 LF) DETAIL 8-2 B= 3 Ft. Min. D= 2.0 Ft. Ground Natural Ground Natural ( Not to Scale) Elevation Natural Bed Ground Natural Type of Liner= CL 'I' Rip-Rap - Keyed-In DETAIL 8-4 BANK STABILIZATION Ground Natural Flatter 2:1 or Flatter 2:1 or -L- STA. 75+80 RT Channel Bed (var) BARNHILL CONTRACTING COMPANY SHEET __ OF __ PERMIT DRAWING FLUME DETAIL FLUME PLAN SWALE 5"6" 5"4" 11" 5' MIN. 2' TRANSITION CL NOT TO SCALE NOT TO SCALE SECTION A SECTION B A B B A CC SECTION C3:13:1 2'0.5'1.5'1.5' NOTES PROJECT. SHALL BE CONSIDERED INCIDENTAL TO THE COST OF THE 5. THE COST AND INSTALLATION OF THE WELDED WIRE FABRIC CONCRETE FOR STRUCTURES. 4. CONCRETE SHALL MEET SPECIFICATIONS FOR CLASS 4000 PROPOSED SWALE GRADING. 3. CONCRETE FLUME SHALL BE PLACED TO TIE TO 2. EXPANSION JOINT SHALL BE 3/4" THICK. 1. SEE PLANS FOR LOCATION OF CONCRETE FLUME. CURB CURBCURB 2" RADIUS 1" RADIUS BEGINNING OF SWALE END FLUME AT FLUME CURB EXPANSION JOINT 1/4" TOOLED RADIUS TOP OF CURB SWALE EXPANSION JOINT 4" THICKNESS JOINTS 6". OF AASHTO M55. LAP ALL MEETING REQUIREMENTS WIRE FABRIC. WIRE 6"x6" W2.1xW2.1 WELDED 4" THICKNESS HYDRAULICSROADWAY DESIGN ENGINEER ENGINEER R/W SHEET NO. SHEET NO.PROJECT REFERENCE NO. INCOMPLETE PLANS DO NOT USE FOR R/W ACQUISITION REVISIONS PENTABLE:FILE:Barnhill_Contracting_Corp\Barnhill-Rocky_Mount_DB\6.0_CAD_BIM\6.2_WIP\Hydraulics\PERMITS_Environmental\Drawings\U5026_HYD_ DETAILS.dgnUSER:NWOMACKDATE:8/17/2020NCDOT_pdf_color_eng_100.pltPLOT DRIVER:4:16:35 PMTIME:NCDOT_TSH.tbl2D-2U-5026 /R-5720 DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED HDR Engineering, Inc. of the Carolinas N.C.B.E.L.S. License Number: F-0116 555 Fayetteville St, Suite 900 Raleigh, N.C. 27601 NOT TO SCALE MODIFIED CONCRETE FLUME DETAIL 15-5 Median Ditch ( Not to Scale) FALSE SUMP S S=Ditch Slope etc. GI L 2'DD20' DETAIL 23-4 C Proposed Ditch 60' TOP EL=176.5 2' min. --L2NB-- STA. 42+90 LT BARNHILL CONTRACTING COMPANY CBCB TO OPEN INV=UNK-UNABLE CB TO OPEN INV=UNK-UNABLE CB TO OPEN INV=UNK-UNABLE CB TO OPEN INV=UNK-UNABLE CB TO OPEN INV=UNK-UNABLE INV=UNK INV=UNK S S S SvvCONC SW 30" CONC C&G WOODS CONC SW 30" CONC C&G WOODS CONC FLUME RIP RAP GR CONC DITCH CONC SW RIP RAP 18" RCP 15" RCP BST 15" RCP S S BST 30" CONC C&GCONC DITCH CONC CONC 18" RCP RIP RAP CONC SW 12" STONE WALL BST RIP RAP CONC 30" CONC C&G BST RIP RAP CONC SW SBST WOODS 8" STONE SR 1770 (EASTERN AVENUE) VARIABLE WIDTH PAVED ROADWAY SR 1770 (EASTERN AVENUE) VARIABLE WIDTH PAVED ROADWAY SR 1003 (RED OAK RD.) VARIABLE WIDTH PAVED ROADWAY SR 1003 (RED OAK RD.) VARIABLE WIDTH PAVED ROADWAYTOP=163.56'TOP=164.33' TOP=165.22' TOP=161.61' DI 15" RCP DI 18" RCP POSSIBLE JB 18" RCP TOP=167.61' SSMH INV IN=151.81' INV OUT=159.21' INV IN=158.18' INV IN=158.28' INV OUT=158.09'8" DIP8" DIP INV OUT=159.61' INV IN=159.72' INV IN=157.06' INV OUT=156.99' INV IN=157.63' INV OUT=157.51' INV IN=158.02'(8"HDPE) 8" HDPE8" DIP 8" DIP15" RCP 15" RCP 15" RCP 8" HDPE TOP=170.43' INV IN=161.28' INV OUT=161.20' 8" HDPE 18" RCP TOP=163.82' INV IN=159.92' INV OUT=158.62' TOP=173.92' INV IN=165.88' INV IN=163.42' INV OUT=163.17' 8" HDPE24" RCP18" RCP 15" RCP 24" RCP CUL1 CUL2 CE1 HW1 CUL3 CUL4 CE2 HW2 DI CONC DITCH SSMH SSMH SSMH SSMH SSMH SSMH DI DI 8" HDPE CBCB CB SSMH DI DI 30" CONC C&GFOUND END NOT SR 1770 (EASTERN AVENUE) VARIABLE WIDTH PAVED ROADWAY CONC MEDIAN 1-6X4 BARREL HH T T T T HH HH HH HH HH HH HH BFP Century Link 6 ", PLASTIC, CITY OF ROCKY MOUNT Century Link, TOLL Conterra Ultra Broadband LLC 12 ", AC, TOWN OF NASHVILLE AT&TAT&T4 ", PLASTIC, CITY OF ROCKYMOUNT BFP WATERVAULT EIP MBLT, LLC PB 28 PG 90 35' SEWER EASEMENT SAPONY CREEK PROPERTIES, LLC EIP EIP EIP EIP JSG INVESTMENT CO., LLC AUTOZONE, INC. SAPONY CREEK PROPERTIES, LLC WHLR-NASHVILLE COMMONS, LLC EIP EIP EIP EIP EIP EIP WILLIAM F. GLOVER SIXTY-FOUR AND E AVE, LLC MURPHY OIL USA, INC MON MON EIP DORIS L. FISHER EASTERN NASH, LLC MON MON EXISTING R/W EXISTING R/WEXISTING R/WEXISTING R/W EXISTING R/WEXISTING R/W EXISTING R/W EXISTING R/WE XIS TI NG R/WEXISTING R/W EXISTING R/W R/W VARIES 60.00'20' SEWER EASEMENT46' ACCESS EASEMENTCLARENDON RD.74.16 LT -EL- 9+91.14 98.79 LT -EL- 12+42.56 75.51 LT -EL- 21+46.02 118.71 LT -EY1- 10+23.18 1SBK BUS 1SBK BUS BST BST WOODS LS HH F OESTATE CO., INC. CAVALIER REAL DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED SEE I NSET ASTA. 1 4 +0 0. 0 0MATCHLINE -Y1- 4SEE SHEET 41 FOR -Y1- PROFILE SEE SHEET 24 FOR -L- PROFILE MATCHLINE -L- STA. 24+00.00, SEE SHEET 5GRAPHIC SCALE 0 252512.5 50 SHEET __ OF __ PERMIT DRAWING LEGEND HYDRAULICSROADWAY DESIGN ENGINEER ENGINEER R/W SHEET NO. SHEET NO.PROJECT REFERENCE NO. INCOMPLETE PLANS DO NOT USE FOR R/W ACQUISITION REVISIONS PENTABLE:FILE:Barnhill_Contracting_Corp\Barnhill-Rocky_Mount_DB\6.0_CAD_BIM\6.2_WIP\Hydraulics\PERMITS_Environmental\Drawings\U5026-R5720_HYD_PRM_WET_PSH.dgnUSER:NWOMACKDATE:6/24/2020NCDOT_pdf_color_eng_100.pltPLOT DRIVER:9:26:49 AMTIME:NCDOT_permits_NOCON.tblDOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED HDR Engineering, Inc. of the Carolinas N.C.B.E.L.S. License Number: F-0116 555 Fayetteville St, Suite 900 Raleigh, N.C. 27601 U-5026 / R-5720 F F FF F F F F F FF F C C CCCF CRCRCR CR15 2015-Y1SPUR- PC Sta. 11+64.36 -Y1- PC Sta. 16+05.56 -Y1SPUR- PT Sta. 12+88.81 -Y1SPUR- POT Sta. 13+46.72 -L- Sta. 19+45.33 = -Y1- Sta. 18+16.39 -Y1- POT Sta. 19+63.14 -Y1-PT Sta. 19+15.23 -L- POT Sta. 10+00.00 -Y1SPUR-BARNHILL CONTRACTING COMPANY NAD 83S S SURFACE WATER DENOTES IMPACTS IN TS TS IMPACTS IN SURFACE WATER DENOTES TEMPORARY SEE SHEET 4A CB CB CB CB DI CB GRADE TO DRAINDI CB CB RETAIN CB RETAIN FOR PROPOSAL UNLESS OTHERWISE NOTED ON THE PLANS. RIGHT-OF-WAY SHALL BE REMOVED AS DESCRIBED IN THE REQUEST ALL EXISTING DRAINAGE STRUCTURES AND PIPES WITHIN PROJECT RETAIN RETAIN RETAIN RETAIN RETAIN RETAIN RETAIN 15" RCP-I V EST 7 SY GF EST 2 TON CLASS B RIP RAP RCP-IV 18" 18" RCP-IV 15" RCP-IV 30" RCP-IV 24" RCP-IV 24" RCP-IV36" RCP- I V15" RCP-IV 15" RCP-IV 36" RCP-IV CB DI 30" RCP-IVDI 15" RCP-IV DI EST 29 SY GF EST 15 TONS CLASS 1 RIP RAP RCP-I V36" 36" RCP-I V24" RCP-IV 24" RCP-IV 15" RCP-IV DETAIL 4-1 SEE SHEET 2D-1 EST 70 SY GEOTEXTILE EST 85 TONS CLASS 'I' RIP RAP HOLE STABILIZATION BANK AND SCOUR RETAIN 2GI-A 30" RCP-IV 2GI-A 2GI-A 2 3 4 5 1 92 1 6 171 SZ-PERENNIAL SITE 1 CBCB TO OPEN INV=UNK-UNABLE CB TO OPEN INV=UNK-UNABLE CB TO OPEN INV=UNK-UNABLE CB TO OPEN INV=UNK-UNABLE CB TO OPEN INV=UNK-UNABLE INV=UNK INV=UNK S S S SvvCONC SW 30" CONC C&G WOODS CONC SW 30" CONC C&G WOODS CONC FLUME RIP RAP GR CONC DITCH CONC SW RIP RAP 18" RCP 15" RCP BST 15" RCP S S BST 30" CONC C&GCONC DITCH CONC CONC 18" RCP RIP RAP CONC SW 12" STONE WALL BST RIP RAP CONC 30" CONC C&G BST RIP RAP CONC SW SBST WOODS 8" STONE SR 1770 (EASTERN AVENUE) VARIABLE WIDTH PAVED ROADWAY SR 1770 (EASTERN AVENUE) VARIABLE WIDTH PAVED ROADWAY SR 1003 (RED OAK RD.) VARIABLE WIDTH PAVED ROADWAY SR 1003 (RED OAK RD.) VARIABLE WIDTH PAVED ROADWAYTOP=163.56'TOP=164.33' TOP=165.22' TOP=161.61' DI 15" RCP DI 18" RCP POSSIBLE JB 18" RCP TOP=167.61' SSMH INV IN=151.81' INV OUT=159.21' INV IN=158.18' INV IN=158.28' INV OUT=158.09'8" DIP8" DIP INV OUT=159.61' INV IN=159.72' INV IN=157.06' INV OUT=156.99' INV IN=157.63' INV OUT=157.51' INV IN=158.02'(8"HDPE) 8" HDPE8" DIP 8" DIP15" RCP 15" RCP 15" RCP 8" HDPE TOP=170.43' INV IN=161.28' INV OUT=161.20' 8" HDPE 18" RCP TOP=163.82' INV IN=159.92' INV OUT=158.62' TOP=173.92' INV IN=165.88' INV IN=163.42' INV OUT=163.17' 8" HDPE24" RCP18" RCP 15" RCP 24" RCP CUL1 CUL2 CE1 HW1 CUL3 CUL4 CE2 HW2 DI CONC DITCH SSMH SSMH SSMH SSMH SSMH SSMH DI DI 8" HDPE CBCB CB SSMH DI DI 30" CONC C&GFOUND END NOT SR 1770 (EASTERN AVENUE) VARIABLE WIDTH PAVED ROADWAY CONC MEDIAN 1-6X4 BARREL HH T T T T HH HH HH HH HH HH HH BFP Century Link 6 ", PLASTIC, CITY OF ROCKY MOUNT Century Link, TOLL Conterra Ultra Broadband LLC 12 ", AC, TOWN OF NASHVILLE AT&TAT&T4 ", PLASTIC, CITY OF ROCKYMOUNT BFP WATERVAULT EIP MBLT, LLC PB 28 PG 90 35' SEWER EASEMENT SAPONY CREEK PROPERTIES, LLC EIP EIP EIP EIP JSG INVESTMENT CO., LLC AUTOZONE, INC. SAPONY CREEK PROPERTIES, LLC WHLR-NASHVILLE COMMONS, LLC EIP EIP EIP EIP EIP EIP WILLIAM F. GLOVER SIXTY-FOUR AND E AVE, LLC MURPHY OIL USA, INC MON MON EIP DORIS L. FISHER EASTERN NASH, LLC MON MON EXISTING R/W EXISTING R/WEXISTING R/WEXISTING R/W EXISTING R/WEXISTING R/W EXISTING R/W EXISTING R/WE XIS TI NG R/WEXISTING R/W EXISTING R/W R/W VARIES 60.00'20' SEWER EASEMENT46' ACCESS EASEMENTCLARENDON RD.74.16 LT -EL- 9+91.14 98.79 LT -EL- 12+42.56 75.51 LT -EL- 21+46.02 118.71 LT -EY1- 10+23.18 1SBK BUS 1SBK BUS BST BST WOODS LS HH F OESTATE CO., INC. CAVALIER REAL DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED SEE I NSET ASTA. 1 4 +0 0. 0 0MATCHLINE -Y1- 4SEE SHEET 41 FOR -Y1- PROFILE SEE SHEET 24 FOR -L- PROFILE MATCHLINE -L- STA. 24+00.00, SEE SHEET 5GRAPHIC SCALE 0 252512.5 50 SHEET __ OF __ PERMIT DRAWING LEGEND HYDRAULICSROADWAY DESIGN ENGINEER ENGINEER R/W SHEET NO. SHEET NO.PROJECT REFERENCE NO. INCOMPLETE PLANS DO NOT USE FOR R/W ACQUISITION REVISIONS PENTABLE:FILE:Barnhill_Contracting_Corp\Barnhill-Rocky_Mount_DB\6.0_CAD_BIM\6.2_WIP\Hydraulics\PERMITS_Environmental\Drawings\U5026-R5720_HYD_PRM_WET_PSH.dgnUSER:NWOMACKDATE:6/24/2020NCDOT_pdf_color_eng_100.pltPLOT DRIVER:9:33:40 AMTIME:NCDOT_permits_CON.tblDOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED HDR Engineering, Inc. of the Carolinas N.C.B.E.L.S. License Number: F-0116 555 Fayetteville St, Suite 900 Raleigh, N.C. 27601 U-5026 / R-5720 150155155155155155155 160160 160160160160160165165165165165 165 165165165 165165 165 165 165165165165165165165 165165165 165 165165165165165165165165165 165165165165 165 165165 165165 170170 170 170170170170170170 1701 7 0 170 170170170170 17017017017 0 170170170 17 5 1751 7 5 17 5 175175175175175175175175 F F FF F F F F F FF F C C CCCF CRCRCR CR15 2015-Y1SPUR- PC Sta. 11+64.36 -Y1- PC Sta. 16+05.56 -Y1SPUR- PT Sta. 12+88.81 -Y1SPUR- POT Sta. 13+46.72 -L- Sta. 19+45.33 = -Y1- Sta. 18+16.39 -Y1- POT Sta. 19+63.14 -Y1-PT Sta. 19+15.23 -L- POT Sta. 10+00.00 -Y1SPUR-BARNHILL CONTRACTING COMPANY NAD 83S S SURFACE WATER DENOTES IMPACTS IN TS TS IMPACTS IN SURFACE WATER DENOTES TEMPORARY SEE SHEET 4A CB CB CB CB DI CB GRADE TO DRAINDI CB CB RETAIN CB RETAIN FOR PROPOSAL UNLESS OTHERWISE NOTED ON THE PLANS. RIGHT-OF-WAY SHALL BE REMOVED AS DESCRIBED IN THE REQUEST ALL EXISTING DRAINAGE STRUCTURES AND PIPES WITHIN PROJECT RETAIN RETAIN RETAIN RETAIN RETAIN RETAIN RETAIN 15" RCP-I V EST 7 SY GF EST 2 TON CLASS B RIP RAP RCP-IV 18" 18" RCP-IV 15" RCP-IV 30" RCP-IV 24" RCP-IV 24" RCP-IV36" RCP- I V15" RCP-IV 15" RCP-IV 36" RCP-IV CB DI 30" RCP-IVDI 15" RCP-IV DI EST 29 SY GF EST 15 TONS CLASS 1 RIP RAP RCP-I V36" 36" RCP-I V24" RCP-IV 24" RCP-IV 15" RCP-IV DETAIL 4-1 SEE SHEET 2D-1 EST 70 SY GEOTEXTILE EST 85 TONS CLASS 'I' RIP RAP HOLE STABILIZATION BANK AND SCOUR RETAIN 2GI-A 30" RCP-IV 2GI-A 2GI-A 2 3 4 5 1 92 1 6 171 SZ-PERENNIAL SITE 1 BST CONC WOODS TOP=161.61' 15" RCP DI 18" RCP INV IN=157.06' INV OUT=156.99'8" DIP15" RCP CUL3 CUL4 CE2 HW2 SSMH CONC MEDIAN 1-6X4 BARRELEXISTING R/WLEGEND GRAPHIC SCALE 0 252512.5 50 NAD 83/ 2011SHEET __ OF __ PERMIT DRAWING TS HYDRAULICSROADWAY DESIGN ENGINEER ENGINEER R/W SHEET NO. SHEET NO.PROJECT REFERENCE NO. INCOMPLETE PLANS DO NOT USE FOR R/W ACQUISITION REVISIONS PENTABLE:FILE:Barnhill_Contracting_Corp\Barnhill-Rocky_Mount_DB\6.0_CAD_BIM\6.2_WIP\Hydraulics\PERMITS_Environmental\Drawings\U5026-R5720_HYD_PRM_WET_PSH.dgnUSER:NWOMACKDATE:6/24/2020NCDOT_pdf_color_eng_100.pltPLOT DRIVER:9:26:57 AMTIME:NCDOT_permits_NOCON.tbl4AU-5026 /R-5720 DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED HDR Engineering, Inc. of the Carolinas N.C.B.E.L.S. License Number: F-0116 555 Fayetteville St, Suite 900 Raleigh, N.C. 27601 F F15SSSURFACE WATER DENOTES IMPACTS IN TS TS IMPACTS IN SURFACE WATER DENOTES TEMPORARY RETAIN RETAIN RETAIN DETAIL 4-1 SEE SHEET 2D-1 EST 70 SY GEOTEXTILE EST 85 TONS CLASS 'I' RIP RAP HOLE STABILIZATION BANK AND SCOUR SZ-PERENNIAL SITE 1 18" RCP CB BLK WALL CB TO OPEN INV=UNK-UNABLE 15" RCP 15" RCP 15" RCP 18" RCP 18" RCPCB CB TOP=177.22' DI CB RCP 24" 42" RCP30" C&GCONC MOUNTABLE CURB24" C&G30" C&G30" C&GCB CB RIP RAP BST 24" CONC C&G 30" CONC C&G CONC SW CONC BST 30" CONC C&G RIP RAP S 30" CONC C&G30" CONC C&GSCONCCONC SW CB CB CONC SW30" CONC C&G30" CONC C&GBST S LTCB HEDGEROW CONC LP 30" CONC C&G CONC SW BST 30" CONC C&G 24" CONC C&G 10" CONC BLOCK CONC SW 24" CONC C&G 30" CONC C&G CONC BST 30" CONC C&G 24" CONC C&GCBCB CB CB CONC30" CONC C&G30" CONC C&G24" CONC C&GCONC SWS 30" CONC C&G 30" CONC C&G BSTBST RIP RAP LTCONCBSTLT BSTBSTSR 1770 (EASTERN AVENUE) VARIABLE WIDTH PAVED ROADWAY CB CB CUL1 CE1 HW1 18" RCP 15" RCP 15" RCP 15" RCP TOP=177.21'TOP=176.92' INV IN=170.38' INV IN=167.10' INV OUT=166.86' CB 24" R CP 18" RCP 18" RCP 18" HDPE 24" RCP 18" RCP 24" RCP 15" RCP 24" RCP 36" RCP24" RCP36" RCP 18" RCP 18" RCP TOP=181.17' INV IN=167.31' INV OUT=167.19'8" HDPETOP=177.68' INV IN=166.38' INV IN=166.47' INV OUT=166.26' 8" HDPE8" HDPETOP=175.85' INV IN=167.07' INV OUT=166.94' TOP=171.81' INV OUT=168.02'8" HDPETOP=174.96' INV IN=164.34' INV OUT=164.17' TOP=172.84' INV IN=162.62' INV OUT=162.49' 8" HDPE 18" RCP 18" RCP CB CB CB DI CB CB CB CB DI CB 48" RCPSSMH SSMH SSMH SSMH SSMH SSMH SSMH CB 24" RCP CB 18" RCPDI 48" RCP 15" HDPE CB 30" RCPCONC MEDIAN THH C T THH HH T HH T T S T HH HH FOAMP HH HH HH HH HH HH BFP 2 ", PLASTIC, CITY OF ROCKYMOUNT 2 ", PLASTIC, CITY OF ROCKYMOUNTConterra Ultra Broadband LLCCentury Link, TOLL Century Link SUDDENLINK Century Link2 ", PLASTIC, CITY OF ROCKYMOUNT2 ", PLASTIC, CITY OF ROCKY MOUNT 2 ", PLASTIC, CITY OF ROCKYMOUNT TOWN OF NASHVILLETOWN OF NASHVILLECentury LinkCentury LinkEIP STATE EMPLOYEES CREDIT UNION 5' DRAINAGE & UTILITY EASEMENT 5' DRAINAGE & UTILITY EASEMENT5' DRAINAGE & UTILITY EASEMENT80.00' 40'X40'SIGN EASEMENT EIP EIPEIP EIP EIP EIP EIP EIP 3MR LIMITED PARTNERSHIP 5' DRAINAGE & UTILITY EASEMENT5' DRAINAGE & UTILITY EASEMENTMORRIS L. YOUNG 5' DRAINAGE & UTILITY EASEMENT NASH CO. ABC BOARD OHI ASSET (NC) NASHVILLE, LLC EXISTING R/W EXISTING R/W EXISTING R/WEXISTING R/WEXISTING R/WEXISTING R/WEXISTING R/W EXISTING R/W EXISTING R/W EXISTING R/W EXISTING R/W R/W VARIES R/W VARIES R/W VARIES 5' DRAINAGE & UTILITY EASEMENT5' DRAINAGE & UTILITY EASEMENTUTILITY EASEMENT DRAINAGE EASEMENT DRAINAGE EASEMENT 46' A C C E S S E A S E ME N T 3MR LIMITED PARTNERSHIP, LLC 3MR LIMITED PARTNERSHIP 5' DRAINAGE & UTILITY EASEMENT5' DRAINAGE & UTILITY EASEMENT S NORTH EASTPOINTE AVESOUTH EASTPOINTE AVEEXIS TIN G R/W(GAS PUMPS) MTL CANOPY 2SBK BUS BST 1SBK BUS 1SBK BUS (WALMART) 1SBK BUS 1SBK BUS EOIEOIMTR C OUTLET LS LS OUTLET LSLS2" PLASTIC24 FO24 FO100 PR2" PLASTIC24 FP2" PLASTIC24 FO MURPHY OIL USA, INC EASTERN NASH, LLC WHLR-NASHVILLE COMMONS, LLC WALMART REAL ESTATE BUSINESSNAD 83/ 2011SHEET __ OF __ PERMIT DRAWING LEGEND GRAPHIC SCALE 0 252512.5 50 5 MATCHLINE -L- STA. 24+00.00, SEE SHEET 4MATCHLINE -L- STA. 37+00.00, SEE SHEET 6SEE SHEET 47 FOR -Y2- PROFILE SEE SHEET 47 FOR -Y1A- PROFILE SEE SHEET 29 FOR -L- PROFILE HYDRAULICSROADWAY DESIGN ENGINEER ENGINEER R/W SHEET NO. SHEET NO.PROJECT REFERENCE NO. INCOMPLETE PLANS DO NOT USE FOR R/W ACQUISITION REVISIONS PENTABLE:FILE:Barnhill_Contracting_Corp\Barnhill-Rocky_Mount_DB\6.0_CAD_BIM\6.2_WIP\Hydraulics\PERMITS_Environmental\Drawings\U5026-R5720_HYD_PRM_WET_PSH.dgnUSER:NWOMACKDATE:6/24/2020NCDOT_pdf_color_eng_100.pltPLOT DRIVER:9:27:09 AMTIME:NCDOT_permits_NOCON.tblDOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED HDR Engineering, Inc. of the Carolinas N.C.B.E.L.S. License Number: F-0116 555 Fayetteville St, Suite 900 Raleigh, N.C. 27601 U-5026 / R-5720 F F F F F F F F F F F F F F F C C F C C FF C C F C CF F F F C F F F F F F CR CRCRCRCR CR CRC R CRC RCRCRCRCR-Y2- POT Sta. 11+59.05 -L- POT Sta. 34+33.27 = -Y1A- POT Sta. 10+00.00 -Y1A- PT Sta. 11+65.27 -L- PT Sta. 29+05.04 = 253035-L- PC Sta. 25+56.48 -L- PRC Sta. 27+22.26 -L- PT Sta. 29+72.37 -L- PC Sta. 31+24.31 -L- PRC Sta. 32+91.57 -L- PT Sta. 34+56.18 -Y2- PC Sta. 10+00.00 -Y2- PT Sta. 11+24.39 -Y1A- POT Sta. 14+80.46 NAD 83/ 2011BARNHILL CONTRACTING COMPANY SITE 2 S S SURFACE WATER DENOTES IMPACTS IN SEE SHEET 5A CB CB CB CBCB CB CBCB CB CB CB 18" RCP-IV CB CB CB CB DI CBCB CB CB CB FOR PROPOSAL UNLESS OTHERWISE NOTED ON THE PLANS. RIGHT-OF-WAY SHALL BE REMOVED AS DESCRIBED IN THE REQUEST ALL EXISTING DRAINAGE STRUCTURES AND PIPES WITHIN PROJECT DI RETAIN RETAIN RETAIN 15" RCP-IV 15" RCP-IV 15" RCP-IV 18" RCP-IV 18" RCP-I V15" RCP-IV 15" RCP-IV RCP-IV 15" 15" RCP-IV CB18" RCP-IV CB 15" RCP-IV CBCB 15" RCP-IV CB CB 24" RCP-IV CB 15" RCP-IV 15" RCP -IV 15" RCP-IV 15" RCP-IV 15" RCP-IV 15" RCP-IV 15" RCP-IV RCP-IV 15" 15" RCP-IV CB24" RCP-I VRCP-IV15" 15" RCP-IV CB RCP-IV 15" RETAINRETAIN RETAIN DI CB RCP-IV 15" GRADE TO DRAIN 2GI-A DETAIL 5-1 SEE SHEET 2D-1 TOE PROTECTION RCP-IV 15" 24" RCP-IV 7 8 93 94 95 96 92 6 171 9 SA-PERENNIAL U-5996/ R-5720 PA- STORMWATER BASIN U-5996/ R-5720 PB- STORMWATER BASIN U-5996/ R-5720 18" RCP CB BLK WALL CB TO OPEN INV=UNK-UNABLE 15" RCP 15" RCP 15" RCP 18" RCP 18" RCPCB CB TOP=177.22' DI CB RCP 24" 42" RCP30" C&GCONC MOUNTABLE CURB24" C&G30" C&G30" C&GCB CB RIP RAP BST 24" CONC C&G 30" CONC C&G CONC SW CONC BST 30" CONC C&G RIP RAP S 30" CONC C&G30" CONC C&GSCONCCONC SW CB CB CONC SW30" CONC C&G30" CONC C&GBST S LTCB HEDGEROW CONC LP 30" CONC C&G CONC SW BST 30" CONC C&G 24" CONC C&G 10" CONC BLOCK CONC SW 24" CONC C&G 30" CONC C&G CONC BST 30" CONC C&G 24" CONC C&GCBCB CB CB CONC30" CONC C&G30" CONC C&G24" CONC C&GCONC SWS 30" CONC C&G 30" CONC C&G BSTBST RIP RAP LTCONCBSTLT BSTBSTSR 1770 (EASTERN AVENUE) VARIABLE WIDTH PAVED ROADWAY CB CB CUL1 CE1 HW1 18" RCP 15" RCP 15" RCP 15" RCP TOP=177.21'TOP=176.92' INV IN=170.38' INV IN=167.10' INV OUT=166.86' CB 24" R CP 18" RCP 18" RCP 18" HDPE 24" RCP 18" RCP 24" RCP 15" RCP 24" RCP 36" RCP24" RCP36" RCP 18" RCP 18" RCP TOP=181.17' INV IN=167.31' INV OUT=167.19'8" HDPETOP=177.68' INV IN=166.38' INV IN=166.47' INV OUT=166.26' 8" HDPE8" HDPETOP=175.85' INV IN=167.07' INV OUT=166.94' TOP=171.81' INV OUT=168.02'8" HDPETOP=174.96' INV IN=164.34' INV OUT=164.17' TOP=172.84' INV IN=162.62' INV OUT=162.49' 8" HDPE 18" RCP 18" RCP CB CB CB DI CB CB CB CB DI CB 48" RCPSSMH SSMH SSMH SSMH SSMH SSMH SSMH CB 24" RCP CB 18" RCPDI 48" RCP 15" HDPE CB 30" RCPCONC MEDIAN THH C T THH HH T HH T T S T HH HH FOAMP HH HH HH HH HH HH BFP 2 ", PLASTIC, CITY OF ROCKYMOUNT 2 ", PLASTIC, CITY OF ROCKYMOUNTConterra Ultra Broadband LLCCentury Link, TOLL Century Link SUDDENLINK Century Link2 ", PLASTIC, CITY OF ROCKYMOUNT2 ", PLASTIC, CITY OF ROCKY MOUNT 2 ", PLASTIC, CITY OF ROCKYMOUNT TOWN OF NASHVILLETOWN OF NASHVILLECentury LinkCentury LinkEIP STATE EMPLOYEES CREDIT UNION 5' DRAINAGE & UTILITY EASEMENT 5' DRAINAGE & UTILITY EASEMENT5' DRAINAGE & UTILITY EASEMENT80.00' 40'X40'SIGN EASEMENT EIP EIPEIP EIP EIP EIP EIP EIP 3MR LIMITED PARTNERSHIP 5' DRAINAGE & UTILITY EASEMENT5' DRAINAGE & UTILITY EASEMENTMORRIS L. YOUNG 5' DRAINAGE & UTILITY EASEMENT NASH CO. ABC BOARD OHI ASSET (NC) NASHVILLE, LLC EXISTING R/W EXISTING R/W EXISTING R/WEXISTING R/WEXISTING R/WEXISTING R/WEXISTING R/W EXISTING R/W EXISTING R/W EXISTING R/W EXISTING R/W R/W VARIES R/W VARIES R/W VARIES 5' DRAINAGE & UTILITY EASEMENT5' DRAINAGE & UTILITY EASEMENTUTILITY EASEMENT DRAINAGE EASEMENT DRAINAGE EASEMENT 46' A C C E S S E A S E ME N T 3MR LIMITED PARTNERSHIP, LLC 3MR LIMITED PARTNERSHIP 5' DRAINAGE & UTILITY EASEMENT5' DRAINAGE & UTILITY EASEMENT S NORTH EASTPOINTE AVESOUTH EASTPOINTE AVEEXIS TIN G R/W(GAS PUMPS) MTL CANOPY 2SBK BUS BST 1SBK BUS 1SBK BUS (WALMART) 1SBK BUS 1SBK BUS EOIEOIMTR C OUTLET LS LS OUTLET LSLS2" PLASTIC24 FO24 FO100 PR2" PLASTIC24 FP2" PLASTIC24 FO MURPHY OIL USA, INC EASTERN NASH, LLC WHLR-NASHVILLE COMMONS, LLC WALMART REAL ESTATE BUSINESSNAD 83/ 2011SHEET __ OF __ PERMIT DRAWING LEGEND GRAPHIC SCALE 0 252512.5 50 5 MATCHLINE -L- STA. 24+00.00, SEE SHEET 4MATCHLINE -L- STA. 37+00.00, SEE SHEET 6SEE SHEET 47 FOR -Y2- PROFILE SEE SHEET 47 FOR -Y1A- PROFILE SEE SHEET 29 FOR -L- PROFILE HYDRAULICSROADWAY DESIGN ENGINEER ENGINEER R/W SHEET NO. SHEET NO.PROJECT REFERENCE NO. INCOMPLETE PLANS DO NOT USE FOR R/W ACQUISITION REVISIONS PENTABLE:FILE:Barnhill_Contracting_Corp\Barnhill-Rocky_Mount_DB\6.0_CAD_BIM\6.2_WIP\Hydraulics\PERMITS_Environmental\Drawings\U5026-R5720_HYD_PRM_WET_PSH.dgnUSER:NWOMACKDATE:6/24/2020NCDOT_pdf_color_eng_100.pltPLOT DRIVER:9:33:46 AMTIME:NCDOT_permits_CON.tblDOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED HDR Engineering, Inc. of the Carolinas N.C.B.E.L.S. License Number: F-0116 555 Fayetteville St, Suite 900 Raleigh, N.C. 27601 U-5026 / R-5720 155160160 160160 165165165165165165165170170170170170170170 170170 170170170175 175175175175 175 1751 7 5 175175175175175175175175175 175175175175175175175175175175175175175 175175 175 175180180180180180180180 180180180FF F F F F F F F F F F F F F C C F C C FF C C F C CF F F F C F F F F F F CR CRCRCRCR CR CRC R CRC RCRCRCRCR-Y2- POT Sta. 11+59.05 -L- POT Sta. 34+33.27 = -Y1A- POT Sta. 10+00.00 -Y1A- PT Sta. 11+65.27 -L- PT Sta. 29+05.04 = 253035-L- PC Sta. 25+56.48 -L- PRC Sta. 27+22.26 -L- PT Sta. 29+72.37 -L- PC Sta. 31+24.31 -L- PRC Sta. 32+91.57 -L- PT Sta. 34+56.18 -Y2- PC Sta. 10+00.00 -Y2- PT Sta. 11+24.39 -Y1A- POT Sta. 14+80.46 NAD 83/ 2011BARNHILL CONTRACTING COMPANY SITE 2 S S SURFACE WATER DENOTES IMPACTS IN SEE SHEET 5A CB CB CB CBCB CB CBCB CB CB CB 18" RCP-IV CB CB CB CB DI CBCB CB CB CB FOR PROPOSAL UNLESS OTHERWISE NOTED ON THE PLANS. RIGHT-OF-WAY SHALL BE REMOVED AS DESCRIBED IN THE REQUEST ALL EXISTING DRAINAGE STRUCTURES AND PIPES WITHIN PROJECT DI RETAIN RETAIN RETAIN 15" RCP-IV 15" RCP-IV 15" RCP-IV 18" RCP-IV 18" RCP-I V15" RCP-IV 15" RCP-IV RCP-IV 15" 15" RCP-IV CB18" RCP-IV CB 15" RCP-IV CBCB 15" RCP-IV CB CB 24" RCP-IV CB 15" RCP-IV 15" RCP -IV 15" RCP-IV 15" RCP-IV 15" RCP-IV 15" RCP-IV 15" RCP-IV RCP-IV 15" 15" RCP-IV CB24" RCP-I VRCP-IV15" 15" RCP-IV CB RCP-IV 15" RETAINRETAIN RETAIN DI CB RCP-IV 15" GRADE TO DRAIN 2GI-A DETAIL 5-1 SEE SHEET 2D-1 TOE PROTECTION RCP-IV 15" 24" RCP-IV 7 8 93 94 95 96 92 6 171 9 SA-PERENNIAL U-5996/ R-5720 PA- STORMWATER BASIN U-5996/ R-5720 PB- STORMWATER BASIN U-5996/ R-5720 S 18" RCP 18" RCP8 " HDP E SSMH 30" CONC C&G 10" CONC BLOCK CONC SW 72" WD WOODS 24" CONC C&G CB 10" CONC WW 18" CONC HW CUL1 CUL2CE1 HW1 18" RCP 8" HDPE 8" HDPE TOP=168.56' INV IN=148.06' INV OUT=147.93' TOP=155.43' INV IN=146.43' INV OUT=146.31'8" HDPE48" RCP18" RCP SSMH SSMH CB 2 ", PLASTIC, CITY OF ROCKYMOUNT EIP OHI ASSET (NC) NASHVILLE, LLC EXISTING R/W EXISTING R/W EXISTING R/W R/W VARIES UTILITY EASEMENT 20' SEWER EASEMENTHH J. MICHAEL EVANS OHI ASSET (NC) NASHVILLE, LLC LEGEND SHEET __ OF __ PERMIT DRAWINGNAD 83/ 2011GRAPHIC SCALE 0 252512.5 50 HYDRAULICSROADWAY DESIGN ENGINEER ENGINEER R/W SHEET NO. SHEET NO.PROJECT REFERENCE NO. INCOMPLETE PLANS DO NOT USE FOR R/W ACQUISITION REVISIONS PENTABLE:FILE:Barnhill_Contracting_Corp\Barnhill-Rocky_Mount_DB\6.0_CAD_BIM\6.2_WIP\Hydraulics\PERMITS_Environmental\Drawings\U5026-R5720_HYD_PRM_WET_PSH.dgnUSER:NWOMACKDATE:8/5/2020NCDOT_pdf_color_eng_100.pltPLOT DRIVER:8:28:50 AMTIME:NCDOT_permits_NOCON.tbl5AU-5026 \R-5720 DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED HDR Engineering, Inc. of the Carolinas N.C.B.E.L.S. License Number: F-0116 555 Fayetteville St, Suite 900 Raleigh, N.C. 27601 TS SURVEYED BY OTHERS F F F F F F C C F -L- PC Sta. 38+49.78 -L- PRC Sta. 40+29.09 S S SURFACE WATER DENOTES IMPACTS IN TS TS IMPACTS IN SURFACE WATER DENOTES TEMPORARY CB CB CB RETAIN 15" RCP-IV 48" RCP-IV15" RCP-IV 15" RCP-IV 15" RCP-IV 15" RCP-IV 15" RCP-IV RCP-IV 48" DETAIL 6-4 SEE SHEET 2D-1 EST 75 SY GF EST 40 TONS ON BANKS ONLY CLASS I RIP RAP OUTLET PROTECTION DETAIL 6-2 SEE SHEET 2D-1 EST 30 CY EXCAVATION EST 70 SY GEOTEXTILE EST 65 TONS CL 'I' RIP RAP CHANNEL IMPROVEMENTS CULVERT DOWNSTREAMDETAIL 6-5 SEE SHEET 2D-1 TOE PROTECTION CB DI CB 2GI-A DETAIL 5-1 SEE SHEET 2D-1 TOE PROTECTION RCP-IV48" HW 97 96 SA-PERENNIAL U-5996/ R-5720 SITE 2 15" RCP15" RCPS 18" RCP8 " HDP E SSMH GRS1SBKDSGR WOODS 72" WD 2SFD BST CONCCONC SW1SBKD1SFDWOODSWOODS WOODS WOODS WOODS WOODS WOODS WOODS WOODS WOODS WOODS GR 1SBKBUS SOIL GR CONC 15" RCP GR CONC 15" RCP WOODS WOODS 36" MTL WW WOODS 12" RCP GR WOODS WELL WOODS WOODS WOODS BST WOODSWOODS GR S SR 1770 (EASTERN AVENUE) VARIABLE WIDTH PAVED ROADWAY FOREST VIEW DR. REGENCY DR. 20' PAVED ROADWAY25 26 30 33 34 DI 10" CONC WW 18" CONC HW CUL2 15" RCP 8" HDPE TOP=168.56' INV IN=148.06' INV OUT=147.93' TOP=155.43' TOP=162.81' INV IN=147.66' INV OUT=147.57' INV IN=146.43' INV OUT=146.31'8" HDPE8" HDPECUL1 CUL2 CUL3 CUL4 CE1 HW1 CUL5 CUL6 CUL7 CUL8 CE2 HW2 8" CONC WW 16" CONC HW 12" HDPE INV=152.41' INV=144.91' 8" CONC WW 16" CONC HW 8" CONC WW 8" CONC WW 48" RCP18" RCP SSMH SSMH SSMH 2-5X8 BARRELS 24" CONC BLOCK CB T T T T ABANDON 2 ", PLASTIC, CITY OF ROCKYMOUNTCentury Link 16 ", DIP, TOWN OF NASHVILLE 12 ", AC, TOWN OF NASHVILLE TOWN OF NASHVILLECentury LinkSUDDENLINK2 ", PLASTIC, CITY OF ROCKYMOUNT KIRBY A WINSTEAD, ET UX WALMART REAL ESTATE BUSINESS EIP BRIAN PULLEN EIP EIP ROY H. BONE, JR. RONNIE P. BURNETTE, ET UX EIP EIP EIP LOUISE F. GOLDSTON FAMILY PARTNERSHIP, NO. 1 THE JAMES D. GOLDSTON, JR & PROPERTIES, LLC NASH MB 3MR LIMITED PARTNERSHIP EXISTING R/W EXISTING R/WEXISTING R/WEXISTING R/W EXISTING R/W EXISTING R/W EXISTING R/W EXISTING R/WEXISTING R/WEXISTING R/W EXISTING R/W R/W VARIES 60.00'60.00'40 .00' 60.00' UTILITY EASEMENT 20' SEWER EASEMENT0.42' EIP TO R/WPASTUREWOODS 1SFD BST 1SFD2SFD 1SBKD 8" DIP2" PLASTICHH 24 FO EXISTING R/W JSR PARTNERS, INC. J. MICHAEL EVANS OHI ASSET (NC) NASHVILLE, LLC RONNIE P. BURNETTE JULIE H. OGBURNNAD 83/ 2011SHEET __ OF __ PERMIT DRAWING LEGEND GRAPHIC SCALE 0 252512.5 50 6 SEE SHEET 44 FOR -RAB1- PROFILE SEE SHEET 48 FOR -Y5- PROFILE SEE SHEET 47 FOR -Y4- PROFILE SEE SHEET 29 & 30 FOR -L- PROFILE SEE SHEET 7MATCHLINE -L- STA. 50+00.00,MATCHLINE -L- STA. 37+00.00, SEE SHEET 5HYDRAULICSROADWAY DESIGN ENGINEER ENGINEER R/W SHEET NO. SHEET NO.PROJECT REFERENCE NO. INCOMPLETE PLANS DO NOT USE FOR R/W ACQUISITION REVISIONS PENTABLE:FILE:Barnhill_Contracting_Corp\Barnhill-Rocky_Mount_DB\6.0_CAD_BIM\6.2_WIP\Hydraulics\PERMITS_Environmental\Drawings\U5026-R5720_HYD_PRM_WET_PSH.dgnUSER:NWOMACKDATE:8/4/2020NCDOT_pdf_color_eng_100.pltPLOT DRIVER:1:38:08 PMTIME:NCDOT_permits_NOCON.tblDOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED HDR Engineering, Inc. of the Carolinas N.C.B.E.L.S. License Number: F-0116 555 Fayetteville St, Suite 900 Raleigh, N.C. 27601 U-5026 / R-5720 SURVEYED BY OTHERS F F F F C C C F C C F CF F F F C C F C F F C C F C C C CCC C C C C CCCF F C C C C F F C FF -Y4- POT Sta. 10+00.00 -L- POT Sta. 40+66.32 = -RAB1- PT Sta. 15+34.07 -RAB1- PC Sta. 10+00.00 = -L- POT Sta. 46+60.33 = -RAB1- POC Sta. 14+04.63 -Y5- POT Sta. 12+39.26 = -RAB1- POC Sta. 12+55.64 -L- POT Sta. 48+30.65 = -Y4- PT Sta. 12+17.12 -Y4- PC Sta. 10+35.19 -Y5- PT Sta. 11+82.23 -Y5- PC Sta. 11+55.66 -Y5- POT Sta. 10+00.00 -Y4- PT Sta. 11+50.92 404550-L- PC Sta. 38+49.78 -L- PRC Sta. 40+29.09 -L- PT Sta. 42+04.29 -L- PC Sta. 46+49.54 -L- PRC Sta. 47+62.02 -L- PT Sta. 48+97.83NAD 83/ 2011BARNHILL CONTRACTING COMPANY S S SURFACE WATER DENOTES IMPACTS IN TS TS IMPACTS IN SURFACE WATER DENOTES TEMPORARY WETLAND DENOTES FILL IN CLEARING DENOTES MECHANIZED* *** *** * F F SEE SHEET 6A SEE SHEET 5A CB CB CB CB EST 7 SY GF EST 2 TONS CLASS B RIP RAP FOR PROPOSAL UNLESS OTHERWISE NOTED ON THE PLANS. RIGHT-OF-WAY SHALL BE REMOVED AS DESCRIBED IN THE REQUEST ALL EXISTING DRAINAGE STRUCTURES AND PIPES WITHIN PROJECT48" RCP-IV2GI 15" RCP-IV 15" RCP-IV 15" RCP-IV 15" RCP-IV EST 7 SY GF EST 2 TON CLASS B RIP RAP EST 7 SY GF EST 2 TON CLASS B RIP RAP CB EST 7 SY GF EST 2 TON CLASS B RIP RAP DI 15" RCP-IV CB DI 15" RCP-IV CB CB CB EST 7 SY GF EST 2 TON CLASS B RIP RAP CB CB 15" RCP-IV RCP-IV 15" RCP-IV 15" RCP-IV 15" DETAIL 6-6 SEE SHEET 2D-1 SPECIAL CUT DITCH DETAIL 6-6 SEE SHEET 2D-1 SPECIAL CUT DITCH RCP-IV 15"RCP-IV15" RCP-IV 48" 18" RCP-IV 18" RCP-IV 18" RCP-IV DETAIL 6-4 SEE SHEET 2D-1 EST 75 SY GF EST 40 TONS ON BANKS ONLY CLASS I RIP RAP OUTLET PROTECTION DETAIL 6-2 SEE SHEET 2D-1 EST 30 CY EXCAVATION EST 70 SY GEOTEXTILE EST 65 TONS CL 'I' RIP RAP CHANNEL IMPROVEMENTS CULVERT DOWNSTREAM DETAIL 6-3 SEE SHEET 2D-1 CHANNEL BLOCK DETAIL 6-5 SEE SHEET 2D-1 TOE PROTECTION DETAIL 6-1 SEE SHEET 2D-1 EST 40 CY EXCAVATION EST 65 SY GEOTEXTILE EST 60 TONS CLASS 'I' RIP RAP CHANNEL IMPROVEMENTS CULVERT UPSTREAM 15" RCP-IV CB DI CB DI 15" RCP-IV RCP-I V1 5" DETAIL 6-6 SEE SHEET 2D-1 SPECIAL CUT DITCH DETAIL 6-6 SEE SHEET 2D-1 SPECIAL CUT DITCH RCP-IV 15" RCP-IV48" EST 7 SY GF EST 2 TON CLASS B RIP RAP EST 7 SY GF EST 2 TON CLASS B RIP RAP DETAIL 6-6 SEE SHEET 2D-1 SPECIAL CUT DITCH EST 7 SY GF EST 2 TON CLASS B RIP RAP EST 7 SY GF EST 2 TON CLASS B RIP RAP HW RCP-IV 15" 2GI DETAIL 6-5 SEE SHEET 2D-1 TOE PROTECTION 15" RCP-IV EACH END W/ 1' SILL ON BURIED 1' 10'X7' RCBC DETAIL 6-5 SEE SHEET 2D-1 TOE PROTECTION DETAIL 5-1 SEE SHEET 2D-1 TOE PROTECTION DETAIL 6-7 SEE SHEET 2D-1 BEHIND RETAINING WALL CONCRETE DITCH 18" RCP-IV 9 10 11 12 13 14 15 97 98 99 100 96 117 SA-PERENNIAL U-5996/ R-5720 SB-PERENNIAL U-5996/ R-5720 WA U-5996/ R-5720 SB-PERENNIAL U-5996/ R-5720 E SITE 2 SITE 3 SITE 4 15" RCP15" RCPS 18" RCP8 " HDP E SSMH GRS1SBKDSGR WOODS 72" WD 2SFD BST CONCCONC SW1SBKD1SFDWOODSWOODS WOODS WOODS WOODS WOODS WOODS WOODS WOODS WOODS WOODS GR 1SBKBUS SOIL GR CONC 15" RCP GR CONC 15" RCP WOODS WOODS 36" MTL WW WOODS 12" RCP GR WOODS WELL WOODS WOODS WOODS BST WOODSWOODS GR S SR 1770 (EASTERN AVENUE) VARIABLE WIDTH PAVED ROADWAY FOREST VIEW DR. REGENCY DR. 20' PAVED ROADWAY25 26 30 33 34 DI 10" CONC WW 18" CONC HW CUL2 15" RCP 8" HDPE TOP=168.56' INV IN=148.06' INV OUT=147.93' TOP=155.43' TOP=162.81' INV IN=147.66' INV OUT=147.57' INV IN=146.43' INV OUT=146.31'8" HDPE8" HDPECUL1 CUL2 CUL3 CUL4 CE1 HW1 CUL5 CUL6 CUL7 CUL8 CE2 HW2 8" CONC WW 16" CONC HW 12" HDPE INV=152.41' INV=144.91' 8" CONC WW 16" CONC HW 8" CONC WW 8" CONC WW 48" RCP18" RCP SSMH SSMH SSMH 2-5X8 BARRELS 24" CONC BLOCK CB T T T T ABANDON 2 ", PLASTIC, CITY OF ROCKYMOUNTCentury Link 16 ", DIP, TOWN OF NASHVILLE 12 ", AC, TOWN OF NASHVILLE TOWN OF NASHVILLECentury LinkSUDDENLINK2 ", PLASTIC, CITY OF ROCKYMOUNT KIRBY A WINSTEAD, ET UX WALMART REAL ESTATE BUSINESS EIP BRIAN PULLEN EIP EIP ROY H. BONE, JR. RONNIE P. BURNETTE, ET UX EIP EIP EIP LOUISE F. GOLDSTON FAMILY PARTNERSHIP, NO. 1 THE JAMES D. GOLDSTON, JR & PROPERTIES, LLC NASH MB 3MR LIMITED PARTNERSHIP EXISTING R/W EXISTING R/WEXISTING R/WEXISTING R/W EXISTING R/W EXISTING R/W EXISTING R/W EXISTING R/WEXISTING R/WEXISTING R/W EXISTING R/W R/W VARIES 60.00'60.00'40 .00' 60.00' UTILITY EASEMENT 20' SEWER EASEMENT0.42' EIP TO R/WPASTUREWOODS 1SFD BST 1SFD2SFD 1SBKD 8" DIP2" PLASTICHH 24 FO EXISTING R/W JSR PARTNERS, INC. J. MICHAEL EVANS OHI ASSET (NC) NASHVILLE, LLC RONNIE P. BURNETTE JULIE H. OGBURNNAD 83/ 2011SHEET __ OF __ PERMIT DRAWING LEGEND GRAPHIC SCALE 0 252512.5 50 6 SEE SHEET 44 FOR -RAB1- PROFILE SEE SHEET 48 FOR -Y5- PROFILE SEE SHEET 47 FOR -Y4- PROFILE SEE SHEET 29 & 30 FOR -L- PROFILE SEE SHEET 7MATCHLINE -L- STA. 50+00.00,MATCHLINE -L- STA. 37+00.00, SEE SHEET 5HYDRAULICSROADWAY DESIGN ENGINEER ENGINEER R/W SHEET NO. SHEET NO.PROJECT REFERENCE NO. INCOMPLETE PLANS DO NOT USE FOR R/W ACQUISITION REVISIONS PENTABLE:FILE:Barnhill_Contracting_Corp\Barnhill-Rocky_Mount_DB\6.0_CAD_BIM\6.2_WIP\Hydraulics\PERMITS_Environmental\Drawings\U5026-R5720_HYD_PRM_WET_PSH.dgnUSER:NWOMACKDATE:8/4/2020NCDOT_pdf_color_eng_100.pltPLOT DRIVER:1:40:49 PMTIME:NCDOT_permits_CON.tblDOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED HDR Engineering, Inc. of the Carolinas N.C.B.E.L.S. License Number: F-0116 555 Fayetteville St, Suite 900 Raleigh, N.C. 27601 U-5026 / R-5720 145145145 145 145145145 150150 150150150150150150150150155155155155155155155155155155155160160160160 16016016016016016 0 160165165165165 1651651651651 6 5 165 170170170170170170170170170170 170170 175175175175175175 175175175175175175180180180180180180185185185185185185SURVEYED BY OTHERS F F F F C C C F C C F CF F F F C C F C F F C C F C C C CCC C C C C CCCF F C C C C F F C FF -Y4- POT Sta. 10+00.00 -L- POT Sta. 40+66.32 = -RAB1- PT Sta. 15+34.07 -RAB1- PC Sta. 10+00.00 = -L- POT Sta. 46+60.33 = -RAB1- POC Sta. 14+04.63 -Y5- POT Sta. 12+39.26 = -RAB1- POC Sta. 12+55.64 -L- POT Sta. 48+30.65 = -Y4- PT Sta. 12+17.12 -Y4- PC Sta. 10+35.19 -Y5- PT Sta. 11+82.23 -Y5- PC Sta. 11+55.66 -Y5- POT Sta. 10+00.00 -Y4- PT Sta. 11+50.92 404550-L- PC Sta. 38+49.78 -L- PRC Sta. 40+29.09 -L- PT Sta. 42+04.29 -L- PC Sta. 46+49.54 -L- PRC Sta. 47+62.02 -L- PT Sta. 48+97.83NAD 83/ 2011BARNHILL CONTRACTING COMPANY S S SURFACE WATER DENOTES IMPACTS IN TS TS IMPACTS IN SURFACE WATER DENOTES TEMPORARY WETLAND DENOTES FILL IN CLEARING DENOTES MECHANIZED* *** *** * F F SEE SHEET 6A SEE SHEET 5A CB CB CB CB EST 7 SY GF EST 2 TONS CLASS B RIP RAP FOR PROPOSAL UNLESS OTHERWISE NOTED ON THE PLANS. RIGHT-OF-WAY SHALL BE REMOVED AS DESCRIBED IN THE REQUEST ALL EXISTING DRAINAGE STRUCTURES AND PIPES WITHIN PROJECT48" RCP-IV2GI 15" RCP-IV 15" RCP-IV 15" RCP-IV 15" RCP-IV EST 7 SY GF EST 2 TON CLASS B RIP RAP EST 7 SY GF EST 2 TON CLASS B RIP RAP CB EST 7 SY GF EST 2 TON CLASS B RIP RAP DI 15" RCP-IV CB DI 15" RCP-IV CB CB CB EST 7 SY GF EST 2 TON CLASS B RIP RAP CB CB 15" RCP-IV RCP-IV 15" RCP-IV 15" RCP-IV 15" DETAIL 6-6 SEE SHEET 2D-1 SPECIAL CUT DITCH DETAIL 6-6 SEE SHEET 2D-1 SPECIAL CUT DITCH RCP-IV 15"RCP-IV15" RCP-IV 48" 18" RCP-IV 18" RCP-IV 18" RCP-IV DETAIL 6-4 SEE SHEET 2D-1 EST 75 SY GF EST 40 TONS ON BANKS ONLY CLASS I RIP RAP OUTLET PROTECTION DETAIL 6-2 SEE SHEET 2D-1 EST 30 CY EXCAVATION EST 70 SY GEOTEXTILE EST 65 TONS CL 'I' RIP RAP CHANNEL IMPROVEMENTS CULVERT DOWNSTREAM DETAIL 6-3 SEE SHEET 2D-1 CHANNEL BLOCK DETAIL 6-5 SEE SHEET 2D-1 TOE PROTECTION DETAIL 6-1 SEE SHEET 2D-1 EST 40 CY EXCAVATION EST 65 SY GEOTEXTILE EST 60 TONS CLASS 'I' RIP RAP CHANNEL IMPROVEMENTS CULVERT UPSTREAM 15" RCP-IV CB DI CB DI 15" RCP-IV RCP-I V1 5" DETAIL 6-6 SEE SHEET 2D-1 SPECIAL CUT DITCH DETAIL 6-6 SEE SHEET 2D-1 SPECIAL CUT DITCH RCP-IV 15" RCP-IV48" EST 7 SY GF EST 2 TON CLASS B RIP RAP EST 7 SY GF EST 2 TON CLASS B RIP RAP DETAIL 6-6 SEE SHEET 2D-1 SPECIAL CUT DITCH EST 7 SY GF EST 2 TON CLASS B RIP RAP EST 7 SY GF EST 2 TON CLASS B RIP RAP HW RCP-IV 15" 2GI DETAIL 6-5 SEE SHEET 2D-1 TOE PROTECTION 15" RCP-IV EACH END W/ 1' SILL ON BURIED 1' 10'X7' RCBC DETAIL 6-5 SEE SHEET 2D-1 TOE PROTECTION DETAIL 5-1 SEE SHEET 2D-1 TOE PROTECTION DETAIL 6-7 SEE SHEET 2D-1 BEHIND RETAINING WALL CONCRETE DITCH 18" RCP-IV 9 10 11 12 13 14 15 97 98 99 100 96 117 SA-PERENNIAL U-5996/ R-5720 SB-PERENNIAL U-5996/ R-5720 WA U-5996/ R-5720 SB-PERENNIAL U-5996/ R-5720 E SITE 2 SITE 3 SITE 4 8 " HDP E SSMH 72" WD 2SFD BST CONCCONC SW1SBKD1SFDWOODSWOODS WOODS WOODS WOODS WOODS WOODS WOODS GR 1SBKBUS SR 1770 (EASTERN AVENUE) VARIABLE WIDTH PAVED ROADWAY FOREST VIEW DR. 25 26 15" RCP TOP=155.43' TOP=162.81' INV IN=147.66' INV OUT=147.57' INV IN=146.43' INV OUT=146.31'8" HDPE8" HDPECUL1 CUL2 CUL3 CUL4 CE1 HW1 CUL5 CUL6 CUL7 CUL8 CE2 HW2 8" CONC WW 16" CONC HW 12" HDPE INV=152.41' INV=144.91' 8" CONC WW 16" CONC HW 8" CONC WW 8" CONC WW SSMH SSMH 2-5X8 BARRELS T T ABANDON SUDDENLINK2 ", PLASTIC, CITY OF ROCKYMOUNT EIP BRIAN PULLEN LOUISE F. GOLDSTON FAMILY PARTNERSHIP, NO. 1 THE JAMES D. GOLDSTON, JR & EXISTING R/W EXISTING R/WEXISTING R/WEXISTING R/W EXISTING R/W 60.00'40 .00'20' SEWER EASEMENTJ. MICHAEL EVANS SHEET __ OF __ PERMIT DRAWING LEGEND NAD 83/ 2011GRAPHIC SCALE 0 252512.5 50 HYDRAULICSROADWAY DESIGN ENGINEER ENGINEER R/W SHEET NO. SHEET NO.PROJECT REFERENCE NO. INCOMPLETE PLANS DO NOT USE FOR R/W ACQUISITION REVISIONS PENTABLE:FILE:Barnhill_Contracting_Corp\Barnhill-Rocky_Mount_DB\6.0_CAD_BIM\6.2_WIP\Hydraulics\PERMITS_Environmental\Drawings\U5026-R5720_HYD_PRM_WET_PSH.dgnUSER:NWOMACKDATE:8/4/2020NCDOT_pdf_color_eng_100.pltPLOT DRIVER:1:43:55 PMTIME:NCDOT_permits_NOCON.tbl6AU-5026 /R-5720 DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED HDR Engineering, Inc. of the Carolinas N.C.B.E.L.S. License Number: F-0116 555 Fayetteville St, Suite 900 Raleigh, N.C. 27601 SURVEYED BY OTHERS F F F F F C C F C F F C F F F -Y4- POT Sta. 10+00.00 -L- POT Sta. 40+66.32 = -Y4- PT Sta. 12+17.12 -Y4- PC Sta. 10+35.19 -Y4- PT Sta. 11+50.92 -L- PRC Sta. 40+29.09 -L- PT Sta. 42+04.29 S S SURFACE WATER DENOTES IMPACTS IN TS TS IMPACTS IN SURFACE WATER DENOTES TEMPORARY WETLAND DENOTES FILL IN CLEARING DENOTES MECHANIZED* *** *** * F F CB CB 2GI 15" RCP-IV 15" RCP-IV DETAIL 6-2 SEE SHEET 2D-1 EST 30 CY EXCAVATION EST 70 SY GEOTEXTILE EST 65 TONS CL 'I' RIP RAP CHANNEL IMPROVEMENTS CULVERT DOWNSTREAM DETAIL 6-1 SEE SHEET 2D-1 EST 40 CY EXCAVATION EST 65 SY GEOTEXTILE EST 60 TONS CLASS 'I' RIP RAP CHANNEL IMPROVEMENTS CULVERT UPSTREAM CB DI 15" RCP-IV DETAIL 6-6 SEE SHEET 2D-1 SPECIAL CUT DITCH DETAIL 6-5 SEE SHEET 2D-1 TOE PROTECTION EACH END W/ 1' SILL ON BURIED 1' 10'X7' RCBC DETAIL 6-5 SEE SHEET 2D-1 TOE PROTECTION DETAIL 6-7 SEE SHEET 2D-1 BEHIND RETAINING WALL CONCRETE DITCH 18" RCP-IV 11 97 98 SB-PERENNIAL U-5996/ R-5720 WA U-5996/ R-5720 SB-PERENNIAL U-5996/ R-5720 E SITE 3 SITE 4 PROFILE ALONG C OF CULVERTL 200'150'100'50'0 50'100'150'200' 140 150 160 170 1' SILL OFFSET 1' FROM INLET BANK LEFT TOP OF BANK RIGHT TOP OF SLOPE= 0.446% CL INV ELEV=143.75 EXISTING STREAM BED BANK RIGHT TOP OF BANK LEFT TOP OF 1' SILL OFFSET 1' FROM INLET STREAM BED PROPOSED CHANNEL STREAM BED PROPOSED CHANNEL SHEET __ OF __ PERMIT DRAWING (3.15:1 SKEWED) 3:1 NORMAL (3.15:1 SKEWED) 3:1 NORMAL SITE 3 HDR Engineering, Inc. of the Carolinas N.C.B.E.L.S. License Number: F-0116 555 Fayetteville St, Suite 900 Raleigh, N.C. 27601 5/14/99SHEET NO.PROJECT REFERENCE NO. HYDRAULICSROADWAY DESIGN ENGINEER ENGINEER U-5026 REVISIONS PENTABLE:FILE:U5026_R5720_PRM_CSRUSER:_USERNAME_DATE:5/21/2020NCDOT_pdf_color_eng_100.pltPLOT DRIVER:12:38:18 PMTIME:NCDOT_PFL_XSC.tblDOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED oGPL=163.1 SKEW = 72 W/ 1' SILLS 1@ 10'X7' RCBC CL STA 40+84 -L- NWS ELEV = 145.1 WSEL = 150.9 PROPOSED 100 YR WSEL = 150.5 PROPOSED 50 YR WETLANDS WETLANDS 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120120 120120 130130 130130 140140 140140 150150 1501508/23/99PROJ. REFERENCE NO.SHEET NO.0 PENTABLE:FILE:U5026_R5720_PRM_XPL_LUSER:_USERNAME_DATE:5/21/2020NCDOT_pdf_color_eng_100.pltPLOT DRIVER:1:06:42 PMTIME:NCDOT_PFL_XSC.tbl150 150 160 160 170 170 140 14041+00.00 150 150 160 160 170 170 140 14041+50.00 150 150 160 160 170 170 140 140 42+00.00 160 160 170 170 150 15042+50.00 X-15U-5026/R-5720 -L- 5 10 SHEET __ OF __ PERMIT DRAWING PERMIT SITE 4 U-5026 155.84 3:1 0.0250.0250.025 163.00163.00-L- EOT 156.62 3:1 0.0250.0250.025 163.48163.483:10.025 157.36 3:1 0.0250.0250.025 164.18164.184 . 2 :1 0.025 159.00 4 .4 :13.4:1 0.0250.025 0.0250.025 165.10165.10 NAD 83/ 2011SHEET __ OF __ PERMIT DRAWING LEGEND 9 SEE SHEET 48 FOR -Y6- PROFILE SEE SHEET 44 FOR -RAB2- PROFILE SEE SHEET 31 FOR -L- PROFILESEE SHEET 10MATCHLINE -L- STA. 89+00.00,MATCHLINE -L- STA. 76+00.00, SEE SHEET 8SEE INSET AMATCHLINE SEE INSET AMATCHLINE HYDRAULICSROADWAY DESIGN ENGINEER ENGINEER R/W SHEET NO. SHEET NO.PROJECT REFERENCE NO. INCOMPLETE PLANS DO NOT USE FOR R/W ACQUISITION REVISIONS PENTABLE:FILE:Barnhill_Contracting_Corp\Barnhill-Rocky_Mount_DB\6.0_CAD_BIM\6.2_WIP\Hydraulics\PERMITS_Environmental\Drawings\U5026-R5720_HYD_PRM_WET_PSH.dgnUSER:CMYERSDATE:8/18/2020NCDOT_pdf_color_eng_100.pltPLOT DRIVER:12:06:54 PMTIME:NCDOT_permits_NOCON.tblDOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED HDR Engineering, Inc. of the Carolinas N.C.B.E.L.S. License Number: F-0116 555 Fayetteville St, Suite 900 Raleigh, N.C. 27601 U-5026 / R-5720 NAD 83/ 2011NAD 83/ 2011 BARNHILL CONTRACTING COMPANY 511.83' RT -L- +01.32 506.89' RT -L- +56.00 1,065.84' RT -L- +09.32 1,070.87' RT -L- +56.56 S TS TS S S SURFACE WATER DENOTES IMPACTS IN TS TS IMPACTS IN SURFACE WATER DENOTES TEMPORARY EST 37 SY GF EST 17 TONS CLASS I RIP RAP EST 2325 CY EXCAVATION STANDARD BASE DITCH SEE SHEET 2D-1 DETAIL 8-2 L=525 FT, SLOPE=0.99% 36" RCP-IV SEE SHEET 2D-1 DETAIL 8-4 CLASS I RIP RAP EST 35 TONS 52 SY GEOTEXTILE BANK STABILIZATION 15" CMP1SMTLBUS48" VINYL SPLIT RAIL 48" VINYL SPLIT RAIL LT S GR 1SFBUS 1SFD HTR S S SOIL SOIL WOODS S MTL GATE SR 1770 (EASTERN AVENUE) VARIABLE WIDTH PAVED ROADWAY 12" RCP 18" RCP T T TC T WATER VAULT 16 ", DIP, TOWN OF NASHVILLE 2 ", PLASTI C, CI TY OF ROCKYMOUNTCent ur y Li nk16 ", DIP, CITY OF ROCKYMOUNT POWER BOX 5' DRAINAGE & UTILITY EASEMENT ROBERT A. GLOVER, ET UX EIP EIP OLLIE A. BASS, JR. OLLIE A. BASS, JR. TOWN OF NASHVILLE 3MR LIMITED PARTNERSHIP EXISTING R/W EXISTING R/W EXI STI NG R/WEXI STI NG R/WEXISTING R/W EXISTING R/W EXISTING R/W EXISTING R/W 60.00'60.00'60.00'CAROLYN R. EGGERS CAROLYN R. EGGERS EIPEXISTING R/WEXISTING R/W60.00' HTR CEOIKALMAR RD. VARIABLE WIDTH PAVED ROADWAYF F F F F F F F F C C C C F C CF FC CF F C F F C C F -RAB2- PT Sta. 15+34.07 -RAB2- PC Sta. 10+00.00 = -L- POT Sta. 78+61.70 = -RAB2- POC Sta. 12+94.57 -L- POT Sta. 80+31.59 = -RAB2- POC Sta. 11+75.57 -Y6- PC Sta. 10+00.00 = -Y6- PT Sta. 12+05.64 -Y6- POT Sta. 13+05.6480 85-L- PRC Sta. 80+24.99 -L- PRC Sta. 79+20.26 -L- PC Sta. 78+40.41 -L- PT Sta. 76+44.29 -L- PCC Sta. 87+14.40 -L-NAD 83/ 2011CB CB CB EST 7 SY GF EST 2 TONS CLASS B RIP RAP EST 21 SY GF EST 8 TONS CLASS B RIP RAP 15" RCP-IV FOR PROPOSAL UNLESS OTHERWISE NOTED ON THE PLANS. RIGHT-OF-WAY SHALL BE REMOVED AS DESCRIBED IN THE REQUEST ALL EXISTING DRAINAGE STRUCTURES AND PIPES WITHIN PROJECT RETAIN 15" RCP-IV 1 5 " RCP-I V30" RCP-IVw/MH JB CB CB 15" RCP-IV EST 7 SY GF EST 2 TON CLASS B RIP RAP EST 7 SY GF EST 2 TON CLASS B RIP RAP CB EST 5 SY GF EST 1 TON CLASS B RIP RAP CB EST 5 SY GF EST 1 TON CLASS B RIP RAP CB EST 7 SY GF EST 2 TON CLASS B RIP RAP CB 15" R C P-IV CB CB CB CB CB 15" RCP-IV CB 15" RCP-IV CB 15" RCP-IV CB R CP-I V 15" RCP-IV 15" RCP-IV 15" R C P-I V 15" RCP-IV 15" RCP-IV 15" DI 15" RCP-IV DETAIL 9-2 SEE SHEET 2D-1 TOE PROTECTION RCP-IV 15" 15" RCP-IV DETAIL 9-1 SEE SHEET 2D-1 SPECIAL CUT DITCH EST 7 SY GF EST 2 TON CLASS B RIP RAP 15" RCP-IV EST 7 SY GF EST 2 TONS AT C/F TRANSITION CLASS B RIP RAP 30" RCP-IV2GI 36" RCP-IV36" RCP-IVSITE 17 28 29 29 105 105 107 169 NAD 83/ 2011SHEET __ OF __ PERMIT DRAWING LEGEND 9 SEE SHEET 48 FOR -Y6- PROFILE SEE SHEET 44 FOR -RAB2- PROFILE SEE SHEET 31 FOR -L- PROFILESEE SHEET 10MATCHLINE -L- STA. 89+00.00,MATCHLINE -L- STA. 76+00.00, SEE SHEET 8SEE INSET AMATCHLINE SEE INSET AMATCHLINE HYDRAULICSROADWAY DESIGN ENGINEER ENGINEER R/W SHEET NO. SHEET NO.PROJECT REFERENCE NO. INCOMPLETE PLANS DO NOT USE FOR R/W ACQUISITION REVISIONS PENTABLE:FILE:Barnhill_Contracting_Corp\Barnhill-Rocky_Mount_DB\6.0_CAD_BIM\6.2_WIP\Hydraulics\PERMITS_Environmental\Drawings\U5026-R5720_HYD_PRM_WET_PSH.dgnUSER:CMYERSDATE:8/18/2020NCDOT_pdf_color_eng_100.pltPLOT DRIVER:12:08:28 PMTIME:NCDOT_permits_CON.tblDOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED HDR Engineering, Inc. of the Carolinas N.C.B.E.L.S. License Number: F-0116 555 Fayetteville St, Suite 900 Raleigh, N.C. 27601 U-5026 / R-5720 NAD 83/ 2011NAD 83/ 2011 BARNHILL CONTRACTING COMPANY 511.83' RT -L- +01.32 506.89' RT -L- +56.00 1,065.84' RT -L- +09.32 1,070.87' RT -L- +56.56 S TS TS S S SURFACE WATER DENOTES IMPACTS IN TS TS IMPACTS IN SURFACE WATER DENOTES TEMPORARY EST 37 SY GF EST 17 TONS CLASS I RIP RAP EST 2325 CY EXCAVATION STANDARD BASE DITCH SEE SHEET 2D-1 DETAIL 8-2 L=525 FT, SLOPE=0.99% 36" RCP-IV SEE SHEET 2D-1 DETAIL 8-4 CLASS I RIP RAP EST 35 TONS 52 SY GEOTEXTILE BANK STABILIZATION 15" CMP1SMTLBUS48" VINYL SPLIT RAIL 48" VINYL SPLIT RAIL LT S GR 1SFBUS 1SFD HTR S S SOIL SOIL WOODS S MTL GATE SR 1770 (EASTERN AVENUE) VARIABLE WIDTH PAVED ROADWAY 12" RCP 18" RCP T T TC T WATER VAULT 16 ", DIP, TOWN OF NASHVILLE 2 ", PLASTI C, CI TY OF ROCKYMOUNTCent ur y Li nk16 ", DIP, CITY OF ROCKYMOUNT POWER BOX 5' DRAINAGE & UTILITY EASEMENT ROBERT A. GLOVER, ET UX EIP EIP OLLIE A. BASS, JR. OLLIE A. BASS, JR. TOWN OF NASHVILLE 3MR LIMITED PARTNERSHIP EXISTING R/W EXISTING R/W EXI STI NG R/WEXI STI NG R/WEXISTING R/W EXISTING R/W EXISTING R/W EXISTING R/W 60.00'60.00'60.00'CAROLYN R. EGGERS CAROLYN R. EGGERS EIPEXISTING R/WEXISTING R/W60.00' HTR CEOIKALMAR RD. VARIABLE WIDTH PAVED ROADWAY190190195 195 1 9 5 195 1 9 5 195195195195 195 195195 195 195195 195195195 1951951951951 9 5 200200200200200 200200 200200200200 200 200 200200 200 200 200205 F F F F F F F F F C C C C F C CF FC CF F C F F C C F -RAB2- PT Sta. 15+34.07 -RAB2- PC Sta. 10+00.00 = -L- POT Sta. 78+61.70 = -RAB2- POC Sta. 12+94.57 -L- POT Sta. 80+31.59 = -RAB2- POC Sta. 11+75.57 -Y6- PC Sta. 10+00.00 = -Y6- PT Sta. 12+05.64 -Y6- POT Sta. 13+05.6480 85-L- PRC Sta. 80+24.99 -L- PRC Sta. 79+20.26 -L- PC Sta. 78+40.41 -L- PT Sta. 76+44.29 -L- PCC Sta. 87+14.40 -L-NAD 83/ 2011CB CB CB EST 7 SY GF EST 2 TONS CLASS B RIP RAP EST 21 SY GF EST 8 TONS CLASS B RIP RAP 15" RCP-IV FOR PROPOSAL UNLESS OTHERWISE NOTED ON THE PLANS. RIGHT-OF-WAY SHALL BE REMOVED AS DESCRIBED IN THE REQUEST ALL EXISTING DRAINAGE STRUCTURES AND PIPES WITHIN PROJECT RETAIN 15" RCP-IV 1 5 " RCP-I V30" RCP-IVw/MH JB CB CB 15" RCP-IV EST 7 SY GF EST 2 TON CLASS B RIP RAP EST 7 SY GF EST 2 TON CLASS B RIP RAP CB EST 5 SY GF EST 1 TON CLASS B RIP RAP CB EST 5 SY GF EST 1 TON CLASS B RIP RAP CB EST 7 SY GF EST 2 TON CLASS B RIP RAP CB 15" R C P-IV CB CB CB CB CB 15" RCP-IV CB 15" RCP-IV CB 15" RCP-IV CB R CP-I V 15" RCP-IV 15" RCP-IV 15" R C P-I V 15" RCP-IV 15" RCP-IV 15" DI 15" RCP-IV DETAIL 9-2 SEE SHEET 2D-1 TOE PROTECTION RCP-IV 15" 15" RCP-IV DETAIL 9-1 SEE SHEET 2D-1 SPECIAL CUT DITCH EST 7 SY GF EST 2 TON CLASS B RIP RAP 15" RCP-IV EST 7 SY GF EST 2 TONS AT C/F TRANSITION CLASS B RIP RAP 30" RCP-IV2GI 36" RCP-IV36" RCP-IVSITE 17 28 29 29 105 105 107 169 SSS30" C&G30" C&G60" CONC 24" C&G 30" C&G30" C&G30" C&G30 " C& G 30" C& G CONC CONC CONC C O N C C O N C C O N CCO N C 30" C & G 3 0 " C&G 30" C&G 30" C&G 30" C&G 30" C&G 24" C&G24" C&GCONC 23' BST 38' BST34' BST 27' B S T 31' BSTBST 24 'VYNYL84" 23' PAVED ROADWAY BK BUS CONC CONC BST BST GR GR 48" WD/FENCE S S MTL HOUSE PUMP S BILLBOARD MTL GR 10' 1SFD WOODS WOODS 30" C&G30" C&GWESTRY RD 32' PAVED ROADWAYCONC ISLAND S S CONC CONC 24" C&G 2SF APARTMENT CONC CONC 24" C&G 2SF APARTMENT CONC S 3-SBW 72" CHL BILLBOARD MTL BST BK BUS OFFICE CONC W /RAMP DECK BST BST S GR 72" CHL 72" CHL 72" CHL 72" CHL S HOUSE PUMP GR GR CONC 30" C& G 30" C & G CONC CONC SBK BUS CONC LT BST BST BSTBSTBSTBSTCO NC(CONC) G RG RCO N CGRCO N CG A TE I RO N72" W RO U GHT I RON72" W ROUG H T 3-SBW72" CHL10' SO IL 1SFDDECKGR15' G RG RCONCBBCONC CONC MTL BUS M TL BU SU /G TANKS DUPLEX 1SF (1) 3,5 4 9 GAL U/G TANK(1) 7,8 13 GAL U/G TANK(1) 8,7 4 9 GAL U/G TANK(1) 9,4 7 1 GAL U/G TANK(1) 9,6 8 8 GAL U/G TANK5' NON-ACCESS, DRAINAGEAND UTILITY EASEMENT UTILITY EASEMENT20' DRAI NAGE ANDUTI LI TY EAS EMENTDRAINAGE AND UTILITYEASEMENT, DETENTION AREA5' DRAINAGE ANDUTILITY EASEMENT5' DRAI NAGE ANDUTI LI TY EA SEM EN T20' UTILITY EASEMENT 5' DRAINAGE AND UTILITY EASEMENT20' DRAINAGEAND UTILITY EASEMENTPDE PDE PDE SUNSETTER PROPERTIES, LLC EDWIN KEITH BONE SHERRY WILCZEWSKI CLIFTON PRICE HARPER, JR.MB 25 PG 199AND UTILITY EASEMENT5' DRAINAGEEXISTING R/WEXISTING R/WEXISTING R/W EXISTING R/WEXISTING R/W EXISTING R/W EIP EIP EIP EIP 83 84 85 86 87 83 83 84 85 86 NATHAN E. WICKSTROM, ET UX 87 LEONARD SULLIVAN EIP EIP EIP TO R/W 12.46' EIP LIMITED PARTNERSHIP CARRIAGE COURT APARTMENTS EIP EIP EIP EIP EIP EIP EIP E IP EIP EXISTING R/W E XISTIN G R/WEXISTING R/WEXISTING R/WEIPE IPEI PWILLIAMS, ET UX DENNIS BRYANT EI PEI PEI PEI P20' U TI LI TY EASEM EN T LIMITSCITY OF ROCKY MOUNTCITY OF ROCKY MOUNT LIMITSCI TY OF ROCKY MOUNT LI MI TS5' DRAINAGE ANDUTILITY EASEMENT 5' D R A IN AG E A N D U T IL IT Y E A SEM EN T W/LTW/LT W /LT W/LT 48" SPLITRAIL 72" WD FENCE 8 " DI P 8" DIP 8" DIP 8" PVC8" PVC ( S E RVI CE) 4" P VC (SERVICE)4" PVC12" PVC 8" DIP 6" DIP 4" PVC (SERVICE)4" PVC (SERVICE)12" PVC 8" PVC8 " D IP 8" DIP8" DI P30" RCP 30" RCP DI 15" RCP CB15" RCP15" RCP CB CURB INLET42" RCPCB 2 4" RCP 18" RCP 15" RCP CB 24" RCP 15" RCP CB 18" RCP CB 15" RCP CB 18" RCP D I W /CONC CAP D I W /CONC CAP CB DI CB 18" RCP DI W/CONC CAP CURB INLET 24" RCP24" RCP24" RCP 24" RCP 24" RCP24" RCPCURB INLET CB 18" RCP CB 18" RCPDI (SERVIC E) 4 " PVC U N K N OW N LT LT LT LT LT LT LT LT LT L T TTT T T T T C T T T T T T PER RECORDSREPEATER A BA NDO N EDCABLE FEEDI NG THH HH 6" PLASTIC 2" PLASTIC6" PLASTIC 6" PLAST IC HH 6" DI 6" DI 24" DI 2 4 " D I24" DI6" DI DUCT BANK DUCT BANK DU CT BA N K6" DI6" DIE N D N OT F O U N D 8 4" VYNYLRCP42" 5' DRAINAGE ANDUTILITY EASEMENT 80.00' SPLITRAIL 48" VYNYL ROADWAY23' PAVED 24" RCP 18" RCP 18" RCPBOX INACCESSIBLE BOX INACCESSIBLE 24" RCPSR 1770 SUNSET AVE 36' PAVED ROADWAY 3 0 " C&G18" RCP2 4" R C P 72" CHL 72" CHL POSTS GUARD 3-SBW72" CHL30" C&GCANOPY MTL 18" RCPPO STSM TL LIMITSROCKY MOUNT CITY OF 36' PA VED R OA D W AYSR 1770 SUN SET A V EN U EUTILITY EASEMENT15' DRAINAGE AND 60.00'(3) 30" RCP RETENTION PIPES JB JB JB S STUBOUT IS LANDGAS P UMP CONC HW WELL MON ITOR ING EASEMENT DRAINAGE AND 24 ' UTILITY UNKNOWN EASEMENTMONMONPAVED ROADWAY VARIESSR 1610 ARROW RD MTRLSLSLSLSC TMTR200 PR2" PLASTIC12" DI P200 PR400 PR100 PR25 PR 12 FO6" DIP 6" DIP T T T T 1SBLKBUS 1SBLKBUS 15" RCP 15" RCP 1SFD BSTGRAVEL ROADWAY VARIESSR 1610 ARROW RD APPROXAPPROXAPPROX 22' PAVED ROADWAY SR 1828 DOZIER RD S LUCILLE D HERBERT HEIRS EXISTING R/W EXISTING R/WEXISTING R/WEXISTING R/WGR10' STEPHENS, ET AL WILLIAM L. SUNSETTER PROPERTIES, LLC PROPERTIES, LLC DAUGHTRIDGE DAUGHTRIDGE PROPERTIES, LLC ET UX SOUTHERLAND, JAMES B. RAY MILES SYKES, ET UX DAUGHTRIDGE PROPERTIES, LLC OWNERS ASSOCIATION THE VILLAGE IN WESTRY CROSSING PROPERTIES, LLC DAUGHTRIDGE NAD 83/ 2011SHEET __ OF __ PERMIT DRAWING LEGEND TS GRAPHIC SCALE 0 252512.5 50 15 SEE SHEET 49 FOR -Y11- PROFILE SEE SHEET 49 FOR -Y10- PROFILE SEE SHEET 45 FOR -RAB5- PROFILE SEE SHEET 34 FOR -L- PROFILESEE SHEET 14MATCHLINE -L- STA. 155+00.00,SEE SHEET 16MATCHLINE -L- STA. 169+00.00,HYDRAULICSROADWAY DESIGN ENGINEER ENGINEER R/W SHEET NO. SHEET NO.PROJECT REFERENCE NO. INCOMPLETE PLANS DO NOT USE FOR R/W ACQUISITION REVISIONS PENTABLE:FILE:Barnhill_Contracting_Corp\Barnhill-Rocky_Mount_DB\6.0_CAD_BIM\6.2_WIP\Hydraulics\PERMITS_Environmental\Drawings\U5026-R5720_HYD_PRM_WET_PSH.dgnUSER:NWOMACKDATE:6/24/2020NCDOT_pdf_color_eng_100.pltPLOT DRIVER:9:27:47 AMTIME:NCDOT_permits_NOCON.tblDOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED HDR Engineering, Inc. of the Carolinas N.C.B.E.L.S. License Number: F-0116 555 Fayetteville St, Suite 900 Raleigh, N.C. 27601 U-5026 / R-5720 F FFF F F F F F C C F C F F F F F F C C C C F F F F F F F F F C F C C C C C C C F F F F CRCRCRCR CRCR CRCRCR CRCR C RCR C R C R CR C R CR CR CR-RAB5- PT Sta. 15+34.07 -RAB5- PC Sta. 10+00.00 = -L- POC Sta. 161+37.16 = -RAB5- POC Sta. 12+42.87 -L- POT Sta. 163+07.73 = -Y10- POT Sta. 10+00.00 -L- POT Sta. 157+24.88 = -Y8- POT Sta. 11+55.03 -L- POT Sta. 157+58.33 =15516016515 -L- PRC Sta. 155+51.92 -Y8- POT Sta. 10+00.00 -Y8- PT Sta. 11+18.56 -Y10- PT Sta. 13+64.16 -Y10- PC Sta. 11+87.05 -L- PRC Sta. 160+72.85 -L- PRC Sta. 164+63.81 -L- PRC Sta. 163+19.01 -Y11- POT Sta. 10+00.00 -Y11- PC Sta. 11+32.31 -Y11-PT Sta. 12+77.50 -Y11- POT Sta. 13+66.94 = -RAB5- Sta. 13+83.99 -Y8- PC Sta. 10+57.74 NAD 83/ 2011BARNHILL CONTRACTING COMPANY S S SURFACE WATER DENOTES IMPACTS IN TS TS IMPACTS IN SURFACE WATER DENOTES TEMPORARY SEE SHEET 15A CB HW CB CB CB 15" RCP-IV CB CB CB CB CB EST 7 SY GF EST 2 TONS CLASS B RIP RAP EST 21 SY GF EST 8 TONS CLASS B RIP RAP CB CB CB48" RCP-IV48" RCP-IVFOR PROPOSAL UNLESS OTHERWISE NOTED ON THE PLANS. RIGHT-OF-WAY SHALL BE REMOVED AS DESCRIBED IN THE REQUEST ALL EXISTING DRAINAGE STRUCTURES AND PIPES WITHIN PROJECT CB RETAIN RETAIN RETAIN RETAIN RCP-IV 15"CB CB CB DI 15" RCP-IV RCP-IV24" 24" RCP-I V 15" R C P-IV 15" R C P -IV DI CB DI DI RCP-IV 15" CB 15" RCP-IV CB DI RCP-IV 15" CB 15" RCP-IV 15" RCP-IV 15" RCP-IV CB CB 48" RCP-IV w/MH JB CB 30" RCP-IV CB 15" RCP-IV 15" RCP-IV 15" RCP-IVDI RCP-I V 15" RCP-IV 15" 24" RCP-IV CB RCP-IV 24" EST 14 SY GF EST 5 TONS CLASS B RIP RAP 30" RCP-IVDETAIL 15-1 SEE SHEET 2D-1 EST 52 SY GEOTEXTILE EST 40 TONS CLASS II RIP RAP OUTLET CHANNEL PROTECTION RCP- I V 18" CB15" RCP-IV OEP OEP OEP GTD RCP-IV 15" RCP-IV 15" RCP-IV 15" RCP-IV 18" RCP-IV 15" R C P-IV 18" R C P-IV 18" RCP-IV 15" RCP -IV 18 "DETAIL 15-2 SEE SHEET 2D-1 SPECIAL LATERAL BASE DITCH TO HW GTD OEP GTD DI EST 7 SY GF EST 2 TONS CLASS B RIP RAP 15" RCP-I V OEPGTD GTD DETAIL 15-3 SEE SHEET 2D-1 TOE PROTECTION 24" RCP-IV DETAIL 15-4 SEE SHEET 2D-1 SPECIAL CUT DITCH 15" RCP-IV 18" 18" DETAIL 15-5 SEE SHEET 2D-2 MODIFIED CONCRETE FLUME 4849 50 51 52 134 135 136 137 138 139 140 167 134 172 173 174 172 173 174 49 48 WZINTERMITTENT SB SITE 5 SSS30" C&G30" C&G60" CONC 24" C&G 30" C&G30" C&G30" C&G30 " C& G 30" C& G CONC CONC CONC C O N C C O N C C O N CCO N C 30" C & G 3 0 " C&G 30" C&G 30" C&G 30" C&G 30" C&G 24" C&G24" C&GCONC 23' BST 38' BST34' BST 27' B S T 31' BSTBST 24 'VYNYL84" 23' PAVED ROADWAY BK BUS CONC CONC BST BST GR GR 48" WD/FENCE S S MTL HOUSE PUMP S BILLBOARD MTL GR 10' 1SFD WOODS WOODS 30" C&G30" C&GWESTRY RD 32' PAVED ROADWAYCONC ISLAND S S CONC CONC 24" C&G 2SF APARTMENT CONC CONC 24" C&G 2SF APARTMENT CONC S 3-SBW 72" CHL BILLBOARD MTL BST BK BUS OFFICE CONC W /RAMP DECK BST BST S GR 72" CHL 72" CHL 72" CHL 72" CHL S HOUSE PUMP GR GR CONC 30" C& G 30" C & G CONC CONC SBK BUS CONC LT BST BST BSTBSTBSTBSTCO NC(CONC) G RG RCO N CGRCO N CG A TE I RO N72" W RO U GHT I RON72" W ROUG H T 3-SBW72" CHL10' SO IL 1SFDDECKGR15' G RG RCONCBBCONC CONC MTL BUS M TL BU SU /G TANKS DUPLEX 1SF (1) 3,5 4 9 GAL U/G TANK(1) 7,8 13 GAL U/G TANK(1) 8,7 4 9 GAL U/G TANK(1) 9,4 7 1 GAL U/G TANK(1) 9,6 8 8 GAL U/G TANK5' NON-ACCESS, DRAINAGEAND UTILITY EASEMENT UTILITY EASEMENT20' DRAI NAGE ANDUTI LI TY EAS EMENTDRAINAGE AND UTILITYEASEMENT, DETENTION AREA5' DRAINAGE ANDUTILITY EASEMENT5' DRAI NAGE ANDUTI LI TY EA SEM EN T20' UTILITY EASEMENT 5' DRAINAGE AND UTILITY EASEMENT20' DRAINAGEAND UTILITY EASEMENTPDE PDE PDE SUNSETTER PROPERTIES, LLC EDWIN KEITH BONE SHERRY WILCZEWSKI CLIFTON PRICE HARPER, JR.MB 25 PG 199AND UTILITY EASEMENT5' DRAINAGEEXISTING R/WEXISTING R/WEXISTING R/W EXISTING R/WEXISTING R/W EXISTING R/W EIP EIP EIP EIP 83 84 85 86 87 83 83 84 85 86 NATHAN E. WICKSTROM, ET UX 87 LEONARD SULLIVAN EIP EIP EIP TO R/W 12.46' EIP LIMITED PARTNERSHIP CARRIAGE COURT APARTMENTS EIP EIP EIP EIP EIP EIP EIP E IP EIP EXISTING R/W E XISTIN G R/WEXISTING R/WEXISTING R/WEIPE IPEI PWILLIAMS, ET UX DENNIS BRYANT EI PEI PEI PEI P20' U TI LI TY EASEM EN T LIMITSCITY OF ROCKY MOUNTCITY OF ROCKY MOUNT LIMITSCI TY OF ROCKY MOUNT LI MI TS5' DRAINAGE ANDUTILITY EASEMENT 5' D R A IN AG E A N D U T IL IT Y E A SEM EN T W/LTW/LT W /LT W/LT 48" SPLITRAIL 72" WD FENCE 8 " DI P 8" DIP 8" DIP 8" PVC8" PVC ( S E RVI CE) 4" P VC (SERVICE)4" PVC12" PVC 8" DIP 6" DIP 4" PVC (SERVICE)4" PVC (SERVICE)12" PVC 8" PVC8 " D IP 8" DIP8" DI P30" RCP 30" RCP DI 15" RCP CB15" RCP15" RCP CB CURB INLET42" RCPCB 2 4" RCP 18" RCP 15" RCP CB 24" RCP 15" RCP CB 18" RCP CB 15" RCP CB 18" RCP D I W /CONC CAP D I W /CONC CAP CB DI CB 18" RCP DI W/CONC CAP CURB INLET 24" RCP24" RCP24" RCP 24" RCP 24" RCP24" RCPCURB INLET CB 18" RCP CB 18" RCPDI (SERVIC E) 4 " PVC U N K N OW N LT LT LT LT LT LT LT LT LT L T TTT T T T T C T T T T T T PER RECORDSREPEATER A BA NDO N EDCABLE FEEDI NG THH HH 6" PLASTIC 2" PLASTIC6" PLASTIC 6" PLAST IC HH 6" DI 6" DI 24" DI 2 4 " D I24" DI6" DI DUCT BANK DUCT BANK DU CT BA N K6" DI6" DIE N D N OT F O U N D 8 4" VYNYLRCP42" 5' DRAINAGE ANDUTILITY EASEMENT 80.00' SPLITRAIL 48" VYNYL ROADWAY23' PAVED 24" RCP 18" RCP 18" RCPBOX INACCESSIBLE BOX INACCESSIBLE 24" RCPSR 1770 SUNSET AVE 36' PAVED ROADWAY 3 0 " C&G18" RCP2 4" R C P 72" CHL 72" CHL POSTS GUARD 3-SBW72" CHL30" C&GCANOPY MTL 18" RCPPO STSM TL LIMITSROCKY MOUNT CITY OF 36' PA VED R OA D W AYSR 1770 SUN SET A V EN U EUTILITY EASEMENT15' DRAINAGE AND 60.00'(3) 30" RCP RETENTION PIPES JB JB JB S STUBOUT IS LANDGAS P UMP CONC HW WELL MON ITOR ING EASEMENT DRAINAGE AND 24 ' UTILITY UNKNOWN EASEMENTMONMONPAVED ROADWAY VARIESSR 1610 ARROW RD MTRLSLSLSLSC TMTR200 PR2" PLASTIC12" DI P200 PR400 PR100 PR25 PR 12 FO6" DIP 6" DIP T T T T 1SBLKBUS 1SBLKBUS 15" RCP 15" RCP 1SFD BSTGRAVEL ROADWAY VARIESSR 1610 ARROW RD APPROXAPPROXAPPROX 22' PAVED ROADWAY SR 1828 DOZIER RD S LUCILLE D HERBERT HEIRS EXISTING R/W EXISTING R/WEXISTING R/WEXISTING R/WGR10' STEPHENS, ET AL WILLIAM L. SUNSETTER PROPERTIES, LLC PROPERTIES, LLC DAUGHTRIDGE DAUGHTRIDGE PROPERTIES, LLC ET UX SOUTHERLAND, JAMES B. RAY MILES SYKES, ET UX DAUGHTRIDGE PROPERTIES, LLC OWNERS ASSOCIATION THE VILLAGE IN WESTRY CROSSING PROPERTIES, LLC DAUGHTRIDGE NAD 83/ 2011SHEET __ OF __ PERMIT DRAWING LEGEND TS GRAPHIC SCALE 0 252512.5 50 15 SEE SHEET 49 FOR -Y11- PROFILE SEE SHEET 49 FOR -Y10- PROFILE SEE SHEET 45 FOR -RAB5- PROFILE SEE SHEET 34 FOR -L- PROFILESEE SHEET 14MATCHLINE -L- STA. 155+00.00,SEE SHEET 16MATCHLINE -L- STA. 169+00.00,HYDRAULICSROADWAY DESIGN ENGINEER ENGINEER R/W SHEET NO. SHEET NO.PROJECT REFERENCE NO. INCOMPLETE PLANS DO NOT USE FOR R/W ACQUISITION REVISIONS PENTABLE:FILE:Barnhill_Contracting_Corp\Barnhill-Rocky_Mount_DB\6.0_CAD_BIM\6.2_WIP\Hydraulics\PERMITS_Environmental\Drawings\U5026-R5720_HYD_PRM_WET_PSH.dgnUSER:NWOMACKDATE:6/24/2020NCDOT_pdf_color_eng_100.pltPLOT DRIVER:9:33:54 AMTIME:NCDOT_permits_CON.tblDOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED HDR Engineering, Inc. of the Carolinas N.C.B.E.L.S. License Number: F-0116 555 Fayetteville St, Suite 900 Raleigh, N.C. 27601 U-5026 / R-5720 195 2002002002002002 0 0200200200200 200 2 0 0 200 2 0 0 2 0 0 200200200200200 200 200200 205 2052 0 5 205205205205205205205205205205 205205205205205205 205 205 205205205205205205205 205205205205205 205205 205205 205 205 210210210210210210210210210210210 210210 210 210210 210 210210 F FFF F F F F F C C F C F F F F F F C C C C F F F F F F F F F C F C C C C C C C F F F F CRCRCRCR CRCR CRCRCR CRCR C RCR C R C R CR C R CR CR CR-RAB5- PT Sta. 15+34.07 -RAB5- PC Sta. 10+00.00 = -L- POC Sta. 161+37.16 = -RAB5- POC Sta. 12+42.87 -L- POT Sta. 163+07.73 = -Y10- POT Sta. 10+00.00 -L- POT Sta. 157+24.88 = -Y8- POT Sta. 11+55.03 -L- POT Sta. 157+58.33 =15516016515 -L- PRC Sta. 155+51.92 -Y8- POT Sta. 10+00.00 -Y8- PT Sta. 11+18.56 -Y10- PT Sta. 13+64.16 -Y10- PC Sta. 11+87.05 -L- PRC Sta. 160+72.85 -L- PRC Sta. 164+63.81 -L- PRC Sta. 163+19.01 -Y11- POT Sta. 10+00.00 -Y11- PC Sta. 11+32.31 -Y11-PT Sta. 12+77.50 -Y11- POT Sta. 13+66.94 = -RAB5- Sta. 13+83.99 -Y8- PC Sta. 10+57.74 NAD 83/ 2011BARNHILL CONTRACTING COMPANY S S SURFACE WATER DENOTES IMPACTS IN TS TS IMPACTS IN SURFACE WATER DENOTES TEMPORARY SEE SHEET 15A CB HW CB CB CB 15" RCP-IV CB CB CB CB CB EST 7 SY GF EST 2 TONS CLASS B RIP RAP EST 21 SY GF EST 8 TONS CLASS B RIP RAP CB CB CB48" RCP-IV48" RCP-IVFOR PROPOSAL UNLESS OTHERWISE NOTED ON THE PLANS. RIGHT-OF-WAY SHALL BE REMOVED AS DESCRIBED IN THE REQUEST ALL EXISTING DRAINAGE STRUCTURES AND PIPES WITHIN PROJECT CB RETAIN RETAIN RETAIN RETAIN RCP-IV 15"CB CB CB DI 15" RCP-IV RCP-IV24" 24" RCP-I V 15" R C P-IV 15" R C P -IV DI CB DI DI RCP-IV 15" CB 15" RCP-IV CB DI RCP-IV 15" CB 15" RCP-IV 15" RCP-IV 15" RCP-IV CB CB 48" RCP-IV w/MH JB CB 30" RCP-IV CB 15" RCP-IV 15" RCP-IV 15" RCP-IVDI RCP-I V 15" RCP-IV 15" 24" RCP-IV CB RCP-IV 24" EST 14 SY GF EST 5 TONS CLASS B RIP RAP 30" RCP-IVDETAIL 15-1 SEE SHEET 2D-1 EST 52 SY GEOTEXTILE EST 40 TONS CLASS II RIP RAP OUTLET CHANNEL PROTECTION RCP- I V 18" CB15" RCP-IV OEP OEP OEP GTD RCP-IV 15" RCP-IV 15" RCP-IV 15" RCP-IV 18" RCP-IV 15" R C P-IV 18" R C P-IV 18" RCP-IV 15" RCP -IV 18 "DETAIL 15-2 SEE SHEET 2D-1 SPECIAL LATERAL BASE DITCH TO HW GTD OEP GTD DI EST 7 SY GF EST 2 TONS CLASS B RIP RAP 15" RCP-I V OEPGTD GTD DETAIL 15-3 SEE SHEET 2D-1 TOE PROTECTION 24" RCP-IV DETAIL 15-4 SEE SHEET 2D-1 SPECIAL CUT DITCH 15" RCP-IV 18" 18" DETAIL 15-5 SEE SHEET 2D-2 MODIFIED CONCRETE FLUME 4849 50 51 52 134 135 136 137 138 139 140 167 134 172 173 174 172 173 174 49 48 WZINTERMITTENT SB SITE 5 30" C&G CONC CONC 30" C&G 30" C&G 23 ' BST CULTIVATED B DECK DECK BK BUS CONC CONC BST S 72" CHL 72" CHL 72" CHL 5' NON-ACCESS, DRAINAGEAND UTILITY EASEMENT 5' DRAINAGE ANDUTILITY EASEMENTDRAINAGE AND UTILITYEASEMENT, DETENTION AREAPDE 5' DRAINAGE AND UTILITY EASEMENT20' DRAINAGEAND UTILITY EASEMENT20' UTILITY EASEMENT EIP EIP EIP EIPEIP LIMITSCITY OF ROCKY MOUNT48" SPLITRAIL CB18" RCP15" RCP CB 15" RCP CB 30" RCP 30" RCP DI 15" RCP LT 6" PLASTIC DUCT BANK 6" DIP SR 1770 SUNSET AVE 36' PAVED ROADWAY 5' DRAINAGE ANDUTILITY EASEMENT CONC HW SUNSETTER PROPERTIES, LLC SHEET __ OF __ PERMIT DRAWING LEGEND TS GRAPHIC SCALE 0 252512.5 50 NAD 83/ 2011HYDRAULICSROADWAY DESIGN ENGINEER ENGINEER R/W SHEET NO. SHEET NO.PROJECT REFERENCE NO. INCOMPLETE PLANS DO NOT USE FOR R/W ACQUISITION REVISIONS PENTABLE:FILE:Barnhill_Contracting_Corp\Barnhill-Rocky_Mount_DB\6.0_CAD_BIM\6.2_WIP\Hydraulics\PERMITS_Environmental\Drawings\U5026-R5720_HYD_PRM_WET_PSH.dgnUSER:NWOMACKDATE:6/24/2020NCDOT_pdf_color_eng_100.pltPLOT DRIVER:9:27:55 AMTIME:NCDOT_permits_NOCON.tbl15AU-5026 /R-5720 DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED HDR Engineering, Inc. of the Carolinas N.C.B.E.L.S. License Number: F-0116 555 Fayetteville St, Suite 900 Raleigh, N.C. 27601 F F F F FF -L- PRC Sta. 152+48.19 -L- PRC Sta. 155+51.92 S S SURFACE WATER DENOTES IMPACTS IN TS TS IMPACTS IN SURFACE WATER DENOTES TEMPORARY CB CB CB CB CB CB48" RCP-IV48" RCP-IV15" RCP-IV CB 15" RCP-IV 15" RCP-IV RCP-IV 18" RCP-IV 18" 48" RCP-IV DETAIL 15-1SEE SHEET 2D-1EST 52 SY GEOTEXTILEEST 40 TONSCLASS II RIP RAPOUTLET CHANNEL PROTECTION DETAIL 15-1 SEE SHEET 2D-1 EST 52 SY GEOTEXTILE EST 40 TONS CLASS II RIP RAP OUTLET CHANNEL PROTECTION CB15" RCP-IV 15" RCP-IV 15" RCP-IV 134 INTERMITTENTSB SITE 5 HTR HTR GRBSTWD GR30" C&G 30" C&G30" C&G 30" C&G 30" C&G 30" C&G 30" C&G 30" C&G 30" C&G 30" C &G 48" CONC CONC BRIDGE CONC48" CONC CONC CONC CONC CONC CONC CONC CONC CONC CONC CONC CONC BSTBST VARI ESBEN LAYTON CI RCLE30" C&G 23' BST 23' BST 24' BST 38' BST BST 24' 25' BST 10' BST S GATE 3-SBW 72" CHL CONC BLK BUS S BILLBOARD MTL GR BST HTR HTR HTR DECK S HOUSE PUMP GARAGE 1SFD 1SFD 16' GR GR GR GR 1SFD 54" CONC WALK 30" C&G 54" CONC WALK S BST BK BUS S CONC CONC BEN LAYTON CIRCLE 18' PAVED ROADWAYGR 10' WOODS CONC 60" CHL BLK BUS 60" CHL CONC WOODS GR 11'10' GR 1SBKD 1SBKD GR GR 48" WW S MTL MTL BUS 60" CHL 48" WW GR TIMBERSLANDSCAPE6" CONC MTL BUS MTL BUS CONC BST BST S 60" CHL CONC CONC 1SBKD GR 48" BK WALL S CONC BILLBOARDMTL BST CONC BK BUS BST 72" CHL CHL72" GATE 24" C&G 24" C&G 24" C&G 24" C&G CONC 24" C&G 24" C&G 24" C&G72" CHL BST BST BST CONC CONC MTL BUS MTL BUS B B GATECHL72"CHL72" 72" CHL BANNER WAY 1 9' P AVED ROADWAYGRGR GRBST72" CHL 3-SB W96" CHL 3-SBW96" CHL 3-SBWCONC15" RCP40' BSTGATERIP RAPRIP RAPRIP RAPBSTBSTBST34' BSTWOODS72" CHLMTL BUSS WD/WALKWAY CONC CONC CONC CONC CONC CONC CONC CONC CONC DECK CONC BST48" CHL GATE ARBOR OFFICEHTR DECK1SFDS15" RCP15" RCPHTRWOODS 48" CHL 48" WW 1-SBW24" RCP W/FES48" CHL 48" CHL CALEB CT 15' GR BUNCH CIRCLE 15' GR20' BST15" RCPDECKHTRDECKHTR15" RCPSSHTRHTRHTRHTRHTRGR15' BSTDECKWOODSWOODSRAPRIPRAPRIP72" CHLCONCSHELTERMTL CANOPYBILLBOARDSCONC48" ROPE CALEB CT 15' GR 24" GUTTER24" GUTTERCONCDECKWOODS SR 1770 SUNSET AVE 25' PAVED ROADWAY SR 1770 SUNSET AVE 25' PAVED ROADWAY 3' PAVED SHOULDER 3' PAVED SHOULDER 3' PAVED SHOULDER 3' PAVED SHOULDER GR12'RAMPWDDECKCONCDECKDECKDECKDECKDECKDECKDECKCONCSHTRHTRHTRHTRHTRBKCONC18'CONC18'CONC18'CONC18'CONC18'CONC26'HEDGE ROWE. TOWER LANE 20' PAVED ROADWAY24" GUTTER24" GUTTERCONC18'CONC26'BKGAZEBODECKDECKRAINBOW LANE 18' PAVED ROADWAYHTRHTRHTRCONCCONCCONCFALLOWWOODSWOODSWOODSWOODSWOODSWOODSWOODSBILLBOARDMTL S S WOODS CHL 48" GR GR 3 2' CONCGR 48" WW 1-SBW48" WW 1-SBW48" WW 1-SBW 48" WW 1-SBW 48" WW 1-SBW24" C&G 24" C&G A/G TANK 48" WW 1-SBW48" WW 1-SBW METERPWRMETERPWRMETERPWRMETERPWRMETERPWRMETERPWRMETERPWR3 0' ACCES S EASEMENT3 0' ACCES S EASEMENT5' DRAINAGE AND UTILITY EASEMENT 5' DRAINAGE AND UTILITY EASEMENT 5' DRAINAGE AND UTILITY EASEMENT 20' SANITARY SEWER EASEMENT 5' DRAINAGE AND UTILITY EASEMENT 20' SANITARY SEWER EASEMENT 20' SANITARY SEWER EASEMENT 20' SANITARY SEWER EASEMENT 5' DRAINAGE AND UTILITY EASEMENT PDE PDEPDEPDEPDE ANGELYN EZZELL TRESSELL HOMES, LLC JLR REAL ESTATE, LLC JONATHAN KURIEN HICKORY PROPERTY, INC. JEFFREY SYKES, ET UX MCKENNY DIXON, JR. JOHN A. DEW DORNGOOD PROPERTIES, LLC R/W MONR/W MONR/W MONR/W MONR/W MONEXISTING R/WEXISTING R/WEIPEIP EIP EIP EIP CONTRACTORS, LLC WILLIAMS GENERAL EXISTING R/W EXISTING R/W 60.00'PROPERTIES, LLC MOMEYER EIP EIP EIP EIP CONTRACTORS, LLC WILLIAMS GENERAL EIP EXISTING R/W EXISTING R/W 60.00'R/WE XISTIN G R/W MON EIP EXISTING R/W EXISTING R/W EXISTING R/W EXI STI NG R/ W EIP PARTNERSHIP MICHEL REAL ESTATE EIP EIPEIPEIPEIPJLR REAL ESTATE, LLCEXISTING R/WEXISTING R/WEXI STI NG R/WEXI STI NG R/WEI PEIPEIPEXISTING R/W EXISTING R/WEXISTING R/WEXISTING R/WEXISTING R/W EXISTING R/W EXISTING R/W VARIESVARIES150' CP&L EASEMENT 150' CP&L EASEMENT150' CP&L EASEMENT150' CP&L EASEMENT150' CP&L EASEMENTCIT Y O F R O C K Y MO U N T LI MIT S ;;; ; ;; ; ; ;;;;20' UTILITY EASEMENT 20' UTILITY EASEMENT 20' UTILITY EASEMENT 20' UTILITY EASEMENT 20' UTILITY EASEMENT BST 22' GR GR BARBARA ANN RICHARDSON 24' BST GATE 12' GR18' GR18' GR15' GRCHL48" 72" WD FENCEGR20' BST40' BST40' 72" CHL24" C&GGRGRFALLOWCONTRACTORS, LLC WILLIAMS GENERAL 15" RCP22 127 128 139 240 21 W/LTW/LT 8" PVC4" PVC (SERVI CE)4" PVC (SERVICE)8" PVC 8" PVC8" PVC8" PVC8" PVC 12" PVC12" DIP 12" DIP12" VCP12" DIP 12" VCP 12" VCP12" VCP4" PVC (SERVICE)10" VCP12" RCP4" PVC (SERVICE) 10" VCP 8" VCP 4" PVC (SERVI CE) 12" RCP 12" RCP 12" RCP 8" PVC8" PVC8" PVC 8" PVC DI 15" RCP 15" RCP18" RCPCB 18" RCP CB CB 24" RCPCB 24" RCP CB 24" RCP 15" RCPCB 24" RCP DI 15" RCP CB 30" RCP 24" RCP CB 15" RCPDI15" RCP DI CB 30" RCP CB 30" RCP 15" R CP CB 15" RCP 15" RCP CB CB 15" RCP CB 54" RCP24" RCP24" HDPE DI12" HDPE24" RCP18" RCPRISERTOP=184.17' DI 15" HDPE15" HDPE DI 24" HDPE DI DI 12" HDPE12" HDPECURB INLET 24" RCP CURB INLET CURB INLET CURB INLET CURB INLET 8" C MP 8" C MP 8" C MP 8" C MPDI36" RCPFES36" RCP DI36" RCP DI36" RCP FES24" RCP24" RCP FESFESFESFESFESFES18" CMP15" RCP18" RCP8" PVC 10" VCP 15" R CP FESLT LT LT LT LT LT LT LT LTLTLTLTLTTTTT T TT T C T C HH SSTT T T T TTT HH HH HHT PER RECORDS REPEATER ABANDONED CABLE FEEDING HH HH 6" PLASTIC 6" PLASTIC 6" PLASTIC 6" PLASTIC 6" PLASTI C6" PLASTIC2" PLASTIC6" PLASTIC 6" PLASTIC 6" PLASTIC 6" PLASTIC CCCT T HH 6" DI 6" DI 6" DI 6" DI 24" DI 6" DI 24" DI 8" UNKNOWN 8" UNKNOWN 6" DI 24" DI 4" PVC 4" PVC 4" PVC PVC6" 6" PVC6" PVCDUCT BANK DUCT BANK DUCT BANK DUCT BANK DUCT BANK DUCT BANK2" PLASTIC2" PLASTIC 6" DI 6" DI 6" DI 8" DI6" DI6" DI 8" DI 24" DI 24" DI 8" PVC48" ROPE48" CHLR/WE XIS TI NG R/WEXISTING 48" CHL48" CHLSR 1770 SUNSET AVE 36' PAVED ROADWAY EXISTING R/W 5' DRAINAGE AND UTILITY EASEMENT R/WEXISTING 60" MTL WW 48" 30" C&G 15" HDPE 60.00'SR 1770 SUNSET AVE 36' PAVED ROADWAY 72" CHL 30" C&G 8" PVC 60.00' BST20' PAVED ROADWAY VARI ABLESR 1667 FREI GHT ROAD72" CHLBILLBOARDMTL R/WEXISTING 60.00' 12" RCP MONR/W 12' PAVED SHOULDER24' CONC ROADWAY4' PAVED SHOULDER4' PAVED SHOULDER24' CONC ROADWAY12' PAVED SHOULDERCABLEMTL MTL MTLMTLMTLMTLMTL MTLCABLE S S S S CONC CONC CONC CONC CONC HWCONC HW4' WW4' WW4' WW4' WW15' UTI LI TY EAS EMENT20' UTILITY EASEMENT 20' UTILITY EASEMENT 20' SANITARY SEWER EASEMENTEAS EMENT20' UTILITY I-95 SBLI-95 NBLUNKNOWN EASEMENTUNKNOWN EASEMENT UNKNOWN EASEMENTUNKNOWN EASEMENT UNKNOWN EASEMENTEASEMENTUNKNOWN EI P PARTNERSHIP MICHEL REAL ESTATE TTEOI25 PR 10 0 P R8 " WILLIAMS GENERAL CONTRACTORS, LLC 3MR LIMITED PARTNERSHIP BKT ENTERPRISES, L.P. FHO PARTNERS, LLC RAY MILES SYKES, ET UX HARPER, JR. CLIFTON PRICE WILLIAM JEFFREY SYKES, ET UX NAD 83/ 2011SHEET __ OF __ PERMIT DRAWING LEGEND 40'RLOCATION: DESIGNED BY: CHECKED BY: COUNTY:TIP NO.: DATE: PLANS 02550 50 100 GRAPHIC SCALE6/2/99PENTABLE:FILE:\USER:NWOMACKDATE:8/21/2020NCDOT_pdf_color_eng_100.pltPLOT DRIVER:11:46:54 AMTIME:NCDOT_permits_NOCON.tbl HYDRAULICSROADWAY DESIGN ENGINEER ENGINEER R/W SHEET NO. SHEET NO.PROJECT REFERENCE NO. INCOMPLETE PLANS DO NOT USE FOR R/W ACQUISITION DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED HDR Engineering, Inc. of the Carolinas N.C.B.E.L.S. License Number: F-0116 555 Fayetteville St, Suite 900 Raleigh, N.C. 27601 U-5026 / R-5720 PI Sta 11+04.20 D L = 102.00' T = 52.14' R = 200.00' PI Sta 11+94.88 D L = 14.79' T = 7.43' R = 65.00' SE = SEE PLANS SE = SEE PLANS -LRPDSPUR- SEE SHEET 22 STA. 16+00.00, MATCHLINE -LRPC- SEE SHEET 22STA. 25+00.00,MATCHLINE -CD1- SEE SHEET 22STA. 30+00.00,MATCHLINE -CD2- SEE SHEET 22 STA. 15+00.00, MATCHLINE -LRPD- SEE SHEET 23STA. 39+00.00,MATCHLINE -CD1- SEE SHEET 23STA. 44+00.00,MATCHLINE -CD2-*INCOMPLETE PLANS DO NOT USE FOR R/W ACQUISITION 16 MATCHLINE -L- STA. 169+00 SEE SHEET 15SEE SHEET 17MATCHLINE -L- STA. 199+00,SEE SHEET 50 FOR -DRIVE2- PROFILE SEE SHEET 49 FOR -Y15- PROFILE SEE SHEET 45 FOR -RAB7- PROFILE SEE SHEET 45 FOR -RAB6- PROFILE SEE SHEET 43 FOR -LRPD- PROFILE SEE SHEET 43 FOR -LLPD- PROFILE SEE SHEET 42 FOR -LRPC- PROFILE SEE SHEET 42 FOR -LLPC- PROFILE SEE SHEET 40 & 41 FOR -CD2- PROFILE SEE SHEET 38 & 39 FOR -CD1- PROFILE SEE SHEET 34 & 35 FOR -L- PROFILE*SKEW = 95°43'12" F F F F FFF F F F F F F F F C F F F F F F F F C C F C F F F F F C F C C C F F F F F C C C C C C C C C C C C C C C F F C CC C C F C C C C C C F FC F F C C C C C C C C C C C F F F F C C C C C F F C C C C F C F F C F F CF C C F F C F F F F F C C C C C F C CRCRCRCRC RCRCRCRCR CR C RCRCRCR C R CRCR CR CR CR CR CR CRCR CRCRCRCR CR CR25303530354040454045-RAB6- POC Sta. 12+71.33 -L- POC Sta. 185+35.93 = -RAB6- P0C Sta. 11+09.84 -LRPC PT Sta. 22+86.02 = -CD1- PT Sta. 29+13.26 -CD1- PC Sta. 25+25.90 -CD1- POT Sta. 32+47.77 -L- POT Sta. 189+80.08 = -L2SB- POT Sta. 42+95.65 -L- POT Sta. 190+49.42 = -CD2- POT Sta. 37+91.78 -L- POT Sta. 192+03.19 = -RAB6- POC Sta. 14+07.73 -Y15- POT Sta. 19+41.79 = -RAB7- PC Sta. 12+80.52 -L- POC Sta. 197+43.15 = 3025 15 -RAB6- PT Sta. 15+34.07 -RAB6- PC Sta. 10+00.00 = -L- POT Sta. 183+65.77 = 12.00' RT. -CD2- POT Sta. 38+04.00, -LLPD- ST Sta. 10+00.00 =170175180185190195POT Sta. 10+00.00 15 20 1 5 15-L- PT Sta. 170+66.99 -L- PC Sta. 172+91.15 -L- PT Sta. 177+58.32 -DRIVE2- POT Sta. 12+50.56 -DRIVE2- PT Sta. 11+66.85 -DRIVE2- PC Sta. 10+51.25 -Y15- PT Sta. 19+23.70 -Y15- PC Sta. 14+18.61 -L- PT Sta. 187+10.33 -L- PRC Sta. 185+83.86 -L- PRC Sta. 184+80.64 -Y15- PRC Sta. 18+49.83 -DRIVE2- POT Sta. 10+00.00 = -Y15- Sta. 17+64.53 -L- PC Sta. 181+91.79 -L- PC Sta. 194+53.21 -L- PRC Sta. 196+22.53 -LRPC- PC Sta. 22+41.01 -LRPC- ST Sta. 18+65.73 -LRPC- CS Sta. 16+09.73 -LLPC- SC Sta. 12+00.00 -LLPC- ST Sta. 10+00.00 = -CD1- Sta. 32+05.59, 12' LT -LLPC- PCC Sta. 17+27.24 -LLPC- PT Sta. 17+70.77 -LLPC- POT Sta. 17+76.19 = -RAB6- Sta. 11+80.04 -LLPD- SC Sta. 12+00.00 -LLPD- PT Sta. 17+63.23 = -RAB7- Sta. 11+36.69 -LLPD- PCC Sta. 16+52.56 -RAB7- Sta. 11+98.86 -L- Sta. 195+72.57 = -RAB7- Sta. 10+00.00 = -RAB7- Sta. 15+34.07 -LRPC- 20 -LRPD- PRC Sta. 22+66.15 -LRPD- PT Sta. 23+27.88 = -LRPD- ST Sta. 20+42.39 -LRPD- CS Sta. 17+86.39 -LR[D- SC Sta. 15+02.2315 Sta. 198+02.71 -L- PT -LRPD- PT Sta. 23+22.71 -L2NB- POT Sta. 43+02.34 -L- POT Sta. 191+33.84 = -LRPD- PC Sta. 21+65.38= -LRPDSPUR- POT Sta. 10+00.00 -LRPDSPUR- PC Sta. 10+52.06 -LRPDSPUR- PT Sta. 11+54.06 PT Sta. 12+02.24 -LRPDSPUR- PC Sta. 11+87.45 -LRPDSPUR-NAD 83/ 201140'RBARNHILL CONTRACTING COMPANY C H O RD C H OR DS S SURFACE WATER DENOTES IMPACTS IN CLEARING DENOTES MECHANIZED* *** *** * E E IN WETLAND DENOTES EXCAVATION SEE SHEET 16B SEE SHEET 16A TS TS IMPACTS IN SURFACE WATER DENOTES TEMPORARY DI DI CB CB CB CB CB CB CB CB CB CB CB 15" RCP-IV CB CB CB CB CB CB CB CB EST 21 SY GF EST 8 TONS CLASS B RIP RAP EST 10 SY GF EST 3 TONS CLASS B RIP RAP CB EST 10 SY GF EST 3 TONS CLASS B RIP RAP EST 14 SY GF EST 5 TONS CLASS B RIP RAP18" RCP-IV15" RCP-IV 15" RCP-IV FOR PROPOSAL UNLESS OTHERWISE NOTED ON THE PLANS. RIGHT-OF-WAY SHALL BE REMOVED AS DESCRIBED IN THE REQUEST ALL EXISTING DRAINAGE STRUCTURES AND PIPES WITHIN PROJECT CB CB HW 15" RCP-IV CB DI DI 15" RCP-I V 15" RCP-IV 18" RCP-IV 18" RCP-IV 24" RCP-IV 24" RCP-IV 24" RCP-IV 30" RCP-IV 30" RCP-IV CB CB CB CB HW TRENCHLESS INSTALLATION 60" WELDED STEEL EST 75 SY GF EST 40 TONS EST 73 SY CLASS I RIP RAP CB CB 15" RCP-IV 15" RCP-IV 15" RCP-IV REMOVE EST 62 SY GF EST 33 TONS EST 60 SY CLASS I RIP RAP 54" RCP-IV RCP-IV 15" EST. 8 TONS CLASS 'B' RIP RAP 21 SY GEO-TEXTILE 15" RCP-IV 15" RCP-IV CB 18" RCP-IV 18" RCP-I V 18" RCP-IV 15" RCP-IV 15" RCP-IV CB CB CB 15" RCP-IV 15" RCP-IV 15" RCP-IV CB CB DI DI DIDI CB 30" RCP-IV 18" RCP-IVDETAIL 16-10 SEE SHEET 2D-1 STANDARD 'V' DITCH 24" RCP-V18" RCP-IV (BURIED 1.0') 60" RCP-IV (BURIED 1.0') 60" RCP-IV EST 10 SY GF EST 3 TONS CLASS B RIP RAP RCP-IV 15" CB DI 15" RCP-IV 24" RCP-IV DI DI DI DI DI DI DI 15" RCP-IV R CP-I V 15" DI DI 15" RCP-IV 15" RCP-IV 30" RCP-IV 15" RCP-IV 30" RCP-IV 30" RCP-IV 18" R C P-I V 15" RCP-IV DETAIL 16-1 SEE SHEET 2D-1 CHANNEL RELOCATION DETAIL 16-2 SEE SHEET 2D-1 CHANNEL RELOCATION DETAIL 16-4 SEE SHEET 2D-1 BERM V DITCH DETAIL 16-5 SEE SHEET 2D-1 SPECIAL CUT DITCH DETAIL 16-7 SEE SHEET 2D-1 STANDARD BASE DITCH DETAIL 16-5 SEE SHEET 2D-1 SPECIAL CUT DITCH DETAIL 16-8 SEE SHEET 2D-1 W/ CLASS B RIP RAP SPECIAL CUT DITCH DETAIL 16-9 SEE SHEET 2D-1 SPECIAL CUT BASE DITCH EST 54 SY GF EST 36 TONS CLASS I RIP RAP BANK STABILIZATION 30" RCP-IV CB CB CB DI CB 2GI-A 2GI-A 2GI-A 30" RCP- I VJB w/MH EST 5 SY GF EST 1 TONS CLASS B RIP RAP BDO 15" RCP-IV GRADE TO DRAIN GRADE TO DRAIN RCP-IV 15" RCP-IV 15" W/ELBOWS15" CSP 15" RCP-IV RCP-IV 18" RCP-IV 15" w/MH JB EST 7 SY GF EST 2 TONS CLASS B RIP RAP 18" RCP-IV 54" RCP-IV GRADE TO DRAIN W/ELBOWS 15" CSP @ 5' SPACING = 86 SLOTS 12" W x 4" H BARRIER SLOT FLOWABLE FILLFILL WITH 2GI RCP-IV 15" 2GI RCP-IV 15" +81.6 BEG. SBG +10.8 END SBG 15" RCP-IV 15" RCP-IV EST 10 SY GF EST 4 TONS EST 9 SY CLASS I RIP RAP 15" CSP w/ELBOWSw/ELBOWS15" CSP 15" RCP-IV 15" R CP-IV 15" RCP-IVDETAIL 16-6 SEE SHEET 2D-1 SPECIAL CUT DITCH DETAIL 16-6 SEE SHEET 2D-1 SPECIAL CUT DITCH EST 7 SY GF EST 2 TONS CLASS B RIP RAP DETAIL 16-5 SEE SHEET 2D-1 SPECIAL CUT DITCH DETAIL 16-8 SEE SHEET 2D-1 W/ CLASS B RIP RAP SPECIAL CUT DITCH EST 7 SY GF EST 2 TONS CLASS B RIP RAP W/E L BOWS 18" CS P CB DETAIL 16-11 SEE SHEET 2D-1 TOE PROTECTION 53 54 59 58 57 56 55 60 61 53 141 142 143 144 145 146 147 70 151 51 53 140 WB WB WJ PERENNIAL SF- INTERMIT SD- INTERMITTENT SF- INTERMITTENT SF- PERENNIAL SF- SITE 6 SITE 6 SITE 7 SITE 15 -L- STA. 198+15 LT D10= 2.2 ft V10= 2.6 fps Q10= 65 cfs D2= 1.9 ft V2= 2.4 fps Q2= 48 cfs SLOPE= 0.44% DA= 59.0 ac STANDARD BASE DITCH DATA -CD1- STA. 15+78 TO STA. 25+00 LT D10= 3.4 ft V10= 1.8 fps Q10= 88 cfs D2= 3.2 ft V2= 1.7 fps Q2= 74 cfs SLOPE= 0.13% DA= 32.0 ac SPECIAL CUT BASE DITCH DATA FINAL DESIGN. 4B/4C AND MAY CHANGE WITH DESIGN CONCEPT USED FOR SITE 7 IS PRELIMINARY DESIGN. NOTE: SITE 8 HTR HTR GRBSTWD GR30" C&G 30" C&G30" C&G 30" C&G 30" C&G 30" C&G 30" C&G 30" C&G 30" C&G 30" C &G 48" CONC CONC BRIDGE CONC48" CONC CONC CONC CONC CONC CONC CONC CONC CONC CONC CONC CONC BSTBST VARI ESBEN LAYTON CI RCLE30" C&G 23' BST 23' BST 24' BST 38' BST BST 24' 25' BST 10' BST S GATE 3-SBW 72" CHL CONC BLK BUS S BILLBOARD MTL GR BST HTR HTR HTR DECK S HOUSE PUMP GARAGE 1SFD 1SFD 16' GR GR GR GR 1SFD 54" CONC WALK 30" C&G 54" CONC WALK S BST BK BUS S CONC CONC BEN LAYTON CIRCLE 18' PAVED ROADWAYGR 10' WOODS CONC 60" CHL BLK BUS 60" CHL CONC WOODS GR 11'10' GR 1SBKD 1SBKD GR GR 48" WW S MTL MTL BUS 60" CHL 48" WW GR TIMBERSLANDSCAPE6" CONC MTL BUS MTL BUS CONC BST BST S 60" CHL CONC CONC 1SBKD GR 48" BK WALL S CONC BILLBOARDMTL BST CONC BK BUS BST 72" CHL CHL72" GATE 24" C&G 24" C&G 24" C&G 24" C&G CONC 24" C&G 24" C&G 24" C&G72" CHL BST BST BST CONC CONC MTL BUS MTL BUS B B GATECHL72"CHL72" 72" CHL BANNER WAY 1 9' P AVED ROADWAYGRGR GRBST72" CHL 3-SB W96" CHL 3-SBW96" CHL 3-SBWCONC15" RCP40' BSTGATERIP RAPRIP RAPRIP RAPBSTBSTBST34' BSTWOODS72" CHLMTL BUSS WD/WALKWAY CONC CONC CONC CONC CONC CONC CONC CONC CONC DECK CONC BST48" CHL GATE ARBOR OFFICEHTR DECK1SFDS15" RCP15" RCPHTRWOODS 48" CHL 48" WW 1-SBW24" RCP W/FES48" CHL 48" CHL CALEB CT 15' GR BUNCH CIRCLE 15' GR20' BST15" RCPDECKHTRDECKHTR15" RCPSSHTRHTRHTRHTRHTRGR15' BSTDECKWOODSWOODSRAPRIPRAPRIP72" CHLCONCSHELTERMTL CANOPYBILLBOARDSCONC48" ROPE CALEB CT 15' GR 24" GUTTER24" GUTTERCONCDECKWOODS SR 1770 SUNSET AVE 25' PAVED ROADWAY SR 1770 SUNSET AVE 25' PAVED ROADWAY 3' PAVED SHOULDER 3' PAVED SHOULDER 3' PAVED SHOULDER 3' PAVED SHOULDER GR12'RAMPWDDECKCONCDECKDECKDECKDECKDECKDECKDECKCONCSHTRHTRHTRHTRHTRBKCONC18'CONC18'CONC18'CONC18'CONC18'CONC26'HEDGE ROWE. TOWER LANE 20' PAVED ROADWAY24" GUTTER24" GUTTERCONC18'CONC26'BKGAZEBODECKDECKRAINBOW LANE 18' PAVED ROADWAYHTRHTRHTRCONCCONCCONCFALLOWWOODSWOODSWOODSWOODSWOODSWOODSWOODSBILLBOARDMTL S S WOODS CHL 48" GR GR 3 2' CONCGR 48" WW 1-SBW48" WW 1-SBW48" WW 1-SBW 48" WW 1-SBW 48" WW 1-SBW24" C&G 24" C&G A/G TANK 48" WW 1-SBW48" WW 1-SBW METERPWRMETERPWRMETERPWRMETERPWRMETERPWRMETERPWRMETERPWR3 0' ACCES S EASEMENT3 0' ACCES S EASEMENT5' DRAINAGE AND UTILITY EASEMENT 5' DRAINAGE AND UTILITY EASEMENT 5' DRAINAGE AND UTILITY EASEMENT 20' SANITARY SEWER EASEMENT 5' DRAINAGE AND UTILITY EASEMENT 20' SANITARY SEWER EASEMENT 20' SANITARY SEWER EASEMENT 20' SANITARY SEWER EASEMENT 5' DRAINAGE AND UTILITY EASEMENT PDE PDEPDEPDEPDE ANGELYN EZZELL TRESSELL HOMES, LLC JLR REAL ESTATE, LLC JONATHAN KURIEN HICKORY PROPERTY, INC. JEFFREY SYKES, ET UX MCKENNY DIXON, JR. JOHN A. DEW DORNGOOD PROPERTIES, LLC R/W MONR/W MONR/W MONR/W MONR/W MONEXISTING R/WEXISTING R/WEIPEIP EIP EIP EIP CONTRACTORS, LLC WILLIAMS GENERAL EXISTING R/W EXISTING R/W 60.00'PROPERTIES, LLC MOMEYER EIP EIP EIP EIP CONTRACTORS, LLC WILLIAMS GENERAL EIP EXISTING R/W EXISTING R/W 60.00'R/WE XISTIN G R/W MON EIP EXISTING R/W EXISTING R/W EXISTING R/W EXI STI NG R/ W EIP PARTNERSHIP MICHEL REAL ESTATE EIP EIPEIPEIPEIPJLR REAL ESTATE, LLCEXISTING R/WEXISTING R/WEXI STI NG R/WEXI STI NG R/WEI PEIPEIPEXISTING R/W EXISTING R/WEXISTING R/WEXISTING R/WEXISTING R/W EXISTING R/W EXISTING R/W VARIESVARIES150' CP&L EASEMENT 150' CP&L EASEMENT150' CP&L EASEMENT150' CP&L EASEMENT150' CP&L EASEMENTCIT Y O F R O C K Y MO U N T LI MIT S ;;; ; ;; ; ; ;;;;20' UTILITY EASEMENT 20' UTILITY EASEMENT 20' UTILITY EASEMENT 20' UTILITY EASEMENT 20' UTILITY EASEMENT BST 22' GR GR BARBARA ANN RICHARDSON 24' BST GATE 12' GR18' GR18' GR15' GRCHL48" 72" WD FENCEGR20' BST40' BST40' 72" CHL24" C&GGRGRFALLOWCONTRACTORS, LLC WILLIAMS GENERAL 15" RCP22 127 128 139 240 21 W/LTW/LT 8" PVC4" PVC (SERVI CE)4" PVC (SERVICE)8" PVC 8" PVC8" PVC8" PVC8" PVC 12" PVC12" DIP 12" DIP12" VCP12" DIP 12" VCP 12" VCP12" VCP4" PVC (SERVICE)10" VCP12" RCP4" PVC (SERVICE) 10" VCP 8" VCP 4" PVC (SERVI CE) 12" RCP 12" RCP 12" RCP 8" PVC8" PVC8" PVC 8" PVC DI 15" RCP 15" RCP18" RCPCB 18" RCP CB CB 24" RCPCB 24" RCP CB 24" RCP 15" RCPCB 24" RCP DI 15" RCP CB 30" RCP 24" RCP CB 15" RCPDI15" RCP DI CB 30" RCP CB 30" RCP 15" R CP CB 15" RCP 15" RCP CB CB 15" RCP CB 54" RCP24" RCP24" HDPE DI12" HDPE24" RCP18" RCPRISERTOP=184.17' DI 15" HDPE15" HDPE DI 24" HDPE DI DI 12" HDPE12" HDPECURB INLET 24" RCP CURB INLET CURB INLET CURB INLET CURB INLET 8" C MP 8" C MP 8" C MP 8" C MPDI36" RCPFES36" RCP DI36" RCP DI36" RCP FES24" RCP24" RCP FESFESFESFESFESFES18" CMP15" RCP18" RCP8" PVC 10" VCP 15" R CP FESLT LT LT LT LT LT LT LT LTLTLTLTLTTTTT T TT T C T C HH SSTT T T T TTT HH HH HHT PER RECORDS REPEATER ABANDONED CABLE FEEDING HH HH 6" PLASTIC 6" PLASTIC 6" PLASTIC 6" PLASTIC 6" PLASTI C6" PLASTIC2" PLASTIC6" PLASTIC 6" PLASTIC 6" PLASTIC 6" PLASTIC CCCT T HH 6" DI 6" DI 6" DI 6" DI 24" DI 6" DI 24" DI 8" UNKNOWN 8" UNKNOWN 6" DI 24" DI 4" PVC 4" PVC 4" PVC PVC6" 6" PVC6" PVCDUCT BANK DUCT BANK DUCT BANK DUCT BANK DUCT BANK DUCT BANK2" PLASTIC2" PLASTIC 6" DI 6" DI 6" DI 8" DI6" DI6" DI 8" DI 24" DI 24" DI 8" PVC48" ROPE48" CHLR/WE XIS TI NG R/WEXISTING 48" CHL48" CHLSR 1770 SUNSET AVE 36' PAVED ROADWAY EXISTING R/W 5' DRAINAGE AND UTILITY EASEMENT R/WEXISTING 60" MTL WW 48" 30" C&G 15" HDPE 60.00'SR 1770 SUNSET AVE 36' PAVED ROADWAY 72" CHL 30" C&G 8" PVC 60.00' BST20' PAVED ROADWAY VARI ABLESR 1667 FREI GHT ROAD72" CHLBILLBOARDMTL R/WEXISTING 60.00' 12" RCP MONR/W 12' PAVED SHOULDER24' CONC ROADWAY4' PAVED SHOULDER4' PAVED SHOULDER24' CONC ROADWAY12' PAVED SHOULDERCABLEMTL MTL MTLMTLMTLMTLMTL MTLCABLE S S S S CONC CONC CONC CONC CONC HWCONC HW4' WW4' WW4' WW4' WW15' UTI LI TY EAS EMENT20' UTILITY EASEMENT 20' UTILITY EASEMENT 20' SANITARY SEWER EASEMENTEAS EMENT20' UTILITY I-95 SBLI-95 NBLUNKNOWN EASEMENTUNKNOWN EASEMENT UNKNOWN EASEMENTUNKNOWN EASEMENT UNKNOWN EASEMENTEASEMENTUNKNOWN EI P PARTNERSHIP MICHEL REAL ESTATE TTEOI25 PR 10 0 P R8 " WILLIAMS GENERAL CONTRACTORS, LLC 3MR LIMITED PARTNERSHIP BKT ENTERPRISES, L.P. FHO PARTNERS, LLC RAY MILES SYKES, ET UX HARPER, JR. CLIFTON PRICE WILLIAM JEFFREY SYKES, ET UX NAD 83/ 2011SHEET __ OF __ PERMIT DRAWING LEGEND 40'RLOCATION: DESIGNED BY: CHECKED BY: COUNTY:TIP NO.: DATE: PLANS 02550 50 100 GRAPHIC SCALE6/2/99PENTABLE:FILE:\USER:NWOMACKDATE:8/21/2020NCDOT_pdf_color_eng_100.pltPLOT DRIVER:11:54:01 AMTIME:NCDOT_permits_CON.tbl HYDRAULICSROADWAY DESIGN ENGINEER ENGINEER R/W SHEET NO. SHEET NO.PROJECT REFERENCE NO. INCOMPLETE PLANS DO NOT USE FOR R/W ACQUISITION DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED HDR Engineering, Inc. of the Carolinas N.C.B.E.L.S. License Number: F-0116 555 Fayetteville St, Suite 900 Raleigh, N.C. 27601 U-5026 / R-5720 PI Sta 11+04.20 D L = 102.00' T = 52.14' R = 200.00' PI Sta 11+94.88 D L = 14.79' T = 7.43' R = 65.00' SE = SEE PLANS SE = SEE PLANS -LRPDSPUR- SEE SHEET 22 STA. 16+00.00, MATCHLINE -LRPC- SEE SHEET 22STA. 25+00.00,MATCHLINE -CD1- SEE SHEET 22STA. 30+00.00,MATCHLINE -CD2- SEE SHEET 22 STA. 15+00.00, MATCHLINE -LRPD- SEE SHEET 23STA. 39+00.00,MATCHLINE -CD1- SEE SHEET 23STA. 44+00.00,MATCHLINE -CD2-*INCOMPLETE PLANS DO NOT USE FOR R/W ACQUISITION 16 MATCHLINE -L- STA. 169+00 SEE SHEET 15SEE SHEET 17MATCHLINE -L- STA. 199+00,SEE SHEET 50 FOR -DRIVE2- PROFILE SEE SHEET 49 FOR -Y15- PROFILE SEE SHEET 45 FOR -RAB7- PROFILE SEE SHEET 45 FOR -RAB6- PROFILE SEE SHEET 43 FOR -LRPD- PROFILE SEE SHEET 43 FOR -LLPD- PROFILE SEE SHEET 42 FOR -LRPC- PROFILE SEE SHEET 42 FOR -LLPC- PROFILE SEE SHEET 40 & 41 FOR -CD2- PROFILE SEE SHEET 38 & 39 FOR -CD1- PROFILE SEE SHEET 34 & 35 FOR -L- PROFILE*SKEW = 95°43'12"16016016016016 5 165 1 6 5165165 165165165165165165165 1651651651651701 7 0 170170 170170170 170 170 170170170170170170170 170 170 170170170170170170170 17017 0 170170170 170170170 170170170170170170170170170170170170170170 170170170170 170170170170170170 170170170 170170170 170 170 170 170 170170 170 170 170 175175175175175175175175175 1751751751751 7 5175175175175175175175175175 175175175175175175 175 175175 175175175175175 175 175 175 175 175175175 175175175175175175175175175175175175175175175175 175 175 175 175 175 175175175175175175175175 1751 7 5 1 7 5175175 175 175175175175 175 175175175 17 5175 175175175 1751751751 7 5 175 175 1 7 5 175 175 175 175 175 175 175 180 180 180180180 180180180180180180180180180 180180180 180 180 18018018018018018018018018018018018018018018018018 0 180180180180180180180 180180180180 180 180 180 180 180 180180180180180 180 180180180180 180 185185185185185185185185185185185185 185 185 185 185 185 185 185 185185 18518518518518518518518518 5 185 18 5 185185185185185185185185185185 185 185 185 185185185 185 185190190190190 190190190190190 190 1 9 0 1 9 0 190190190190190190190190 190 190 190 190190190190190 190 190 190 190 195195195195195195195195195195195195195195195 195195 195195195195 195 195 195195 195 200 200200 200205205205 F F F F FFF F F F F F F F F C F F F F F F F F C C F C F F F F F C F C C C F F F F F C C C C C C C C C C C C C C C F F C CC C C F C C C C C C F FC F F C C C C C C C C C C C F F F F C C C C C F F C C C C F C F F C F F CF C C F F C F F F F F C C C C C F C CRCRCRCRC RCRCRCRCR CR C RCRCRCR C R CRCR CR CR CR CR CR CRCR CRCRCRCR CR CR25303530354040454045-RAB6- POC Sta. 12+71.33 -L- POC Sta. 185+35.93 = -RAB6- P0C Sta. 11+09.84 -LRPC PT Sta. 22+86.02 = -CD1- PT Sta. 29+13.26 -CD1- PC Sta. 25+25.90 -CD1- POT Sta. 32+47.77 -L- POT Sta. 189+80.08 = -L2SB- POT Sta. 42+95.65 -L- POT Sta. 190+49.42 = -CD2- POT Sta. 37+91.78 -L- POT Sta. 192+03.19 = -RAB6- POC Sta. 14+07.73 -Y15- POT Sta. 19+41.79 = -RAB7- PC Sta. 12+80.52 -L- POC Sta. 197+43.15 = 3025 15 -RAB6- PT Sta. 15+34.07 -RAB6- PC Sta. 10+00.00 = -L- POT Sta. 183+65.77 = 12.00' RT. -CD2- POT Sta. 38+04.00, -LLPD- ST Sta. 10+00.00 =170175180185190195POT Sta. 10+00.00 15 20 1 5 15-L- PT Sta. 170+66.99 -L- PC Sta. 172+91.15 -L- PT Sta. 177+58.32 -DRIVE2- POT Sta. 12+50.56 -DRIVE2- PT Sta. 11+66.85 -DRIVE2- PC Sta. 10+51.25 -Y15- PT Sta. 19+23.70 -Y15- PC Sta. 14+18.61 -L- PT Sta. 187+10.33 -L- PRC Sta. 185+83.86 -L- PRC Sta. 184+80.64 -Y15- PRC Sta. 18+49.83 -DRIVE2- POT Sta. 10+00.00 = -Y15- Sta. 17+64.53 -L- PC Sta. 181+91.79 -L- PC Sta. 194+53.21 -L- PRC Sta. 196+22.53 -LRPC- PC Sta. 22+41.01 -LRPC- ST Sta. 18+65.73 -LRPC- CS Sta. 16+09.73 -LLPC- SC Sta. 12+00.00 -LLPC- ST Sta. 10+00.00 = -CD1- Sta. 32+05.59, 12' LT -LLPC- PCC Sta. 17+27.24 -LLPC- PT Sta. 17+70.77 -LLPC- POT Sta. 17+76.19 = -RAB6- Sta. 11+80.04 -LLPD- SC Sta. 12+00.00 -LLPD- PT Sta. 17+63.23 = -RAB7- Sta. 11+36.69 -LLPD- PCC Sta. 16+52.56 -RAB7- Sta. 11+98.86 -L- Sta. 195+72.57 = -RAB7- Sta. 10+00.00 = -RAB7- Sta. 15+34.07 -LRPC- 20 -LRPD- PRC Sta. 22+66.15 -LRPD- PT Sta. 23+27.88 = -LRPD- ST Sta. 20+42.39 -LRPD- CS Sta. 17+86.39 -LR[D- SC Sta. 15+02.2315 Sta. 198+02.71 -L- PT -LRPD- PT Sta. 23+22.71 -L2NB- POT Sta. 43+02.34 -L- POT Sta. 191+33.84 = -LRPD- PC Sta. 21+65.38= -LRPDSPUR- POT Sta. 10+00.00 -LRPDSPUR- PC Sta. 10+52.06 -LRPDSPUR- PT Sta. 11+54.06 PT Sta. 12+02.24 -LRPDSPUR- PC Sta. 11+87.45 -LRPDSPUR-NAD 83/ 201140'RBARNHILL CONTRACTING COMPANY C H O RD C H OR DS S SURFACE WATER DENOTES IMPACTS IN CLEARING DENOTES MECHANIZED* *** *** * E E IN WETLAND DENOTES EXCAVATION SEE SHEET 16B SEE SHEET 16A TS TS IMPACTS IN SURFACE WATER DENOTES TEMPORARY DI DI CB CB CB CB CB CB CB CB CB CB CB 15" RCP-IV CB CB CB CB CB CB CB CB EST 21 SY GF EST 8 TONS CLASS B RIP RAP EST 10 SY GF EST 3 TONS CLASS B RIP RAP CB EST 10 SY GF EST 3 TONS CLASS B RIP RAP EST 14 SY GF EST 5 TONS CLASS B RIP RAP18" RCP-IV15" RCP-IV 15" RCP-IV FOR PROPOSAL UNLESS OTHERWISE NOTED ON THE PLANS. RIGHT-OF-WAY SHALL BE REMOVED AS DESCRIBED IN THE REQUEST ALL EXISTING DRAINAGE STRUCTURES AND PIPES WITHIN PROJECT CB CB HW 15" RCP-IV CB DI DI 15" RCP-I V 15" RCP-IV 18" RCP-IV 18" RCP-IV 24" RCP-IV 24" RCP-IV 24" RCP-IV 30" RCP-IV 30" RCP-IV CB CB CB CB HW TRENCHLESS INSTALLATION 60" WELDED STEEL EST 75 SY GF EST 40 TONS EST 73 SY CLASS I RIP RAP CB CB 15" RCP-IV 15" RCP-IV 15" RCP-IV REMOVE EST 62 SY GF EST 33 TONS EST 60 SY CLASS I RIP RAP 54" RCP-IV RCP-IV 15" EST. 8 TONS CLASS 'B' RIP RAP 21 SY GEO-TEXTILE 15" RCP-IV 15" RCP-IV CB 18" RCP-IV 18" RCP-I V 18" RCP-IV 15" RCP-IV 15" RCP-IV CB CB CB 15" RCP-IV 15" RCP-IV 15" RCP-IV CB CB DI DI DIDI CB 30" RCP-IV 18" RCP-IVDETAIL 16-10 SEE SHEET 2D-1 STANDARD 'V' DITCH 24" RCP-V18" RCP-IV (BURIED 1.0') 60" RCP-IV (BURIED 1.0') 60" RCP-IV EST 10 SY GF EST 3 TONS CLASS B RIP RAP RCP-IV 15" CB DI 15" RCP-IV 24" RCP-IV DI DI DI DI DI DI DI 15" RCP-IV R CP-I V 15" DI DI 15" RCP-IV 15" RCP-IV 30" RCP-IV 15" RCP-IV 30" RCP-IV 30" RCP-IV 18" R C P-I V 15" RCP-IV DETAIL 16-1 SEE SHEET 2D-1 CHANNEL RELOCATION DETAIL 16-2 SEE SHEET 2D-1 CHANNEL RELOCATION DETAIL 16-4 SEE SHEET 2D-1 BERM V DITCH DETAIL 16-5 SEE SHEET 2D-1 SPECIAL CUT DITCH DETAIL 16-7 SEE SHEET 2D-1 STANDARD BASE DITCH DETAIL 16-5 SEE SHEET 2D-1 SPECIAL CUT DITCH DETAIL 16-8 SEE SHEET 2D-1 W/ CLASS B RIP RAP SPECIAL CUT DITCH DETAIL 16-9 SEE SHEET 2D-1 SPECIAL CUT BASE DITCH EST 54 SY GF EST 36 TONS CLASS I RIP RAP BANK STABILIZATION 30" RCP-IV CB CB CB DI CB 2GI-A 2GI-A 2GI-A 30" RCP- I VJB w/MH EST 5 SY GF EST 1 TONS CLASS B RIP RAP BDO 15" RCP-IV GRADE TO DRAIN GRADE TO DRAIN RCP-IV 15" RCP-IV 15" W/ELBOWS15" CSP 15" RCP-IV RCP-IV 18" RCP-IV 15" w/MH JB EST 7 SY GF EST 2 TONS CLASS B RIP RAP 18" RCP-IV 54" RCP-IV GRADE TO DRAIN W/ELBOWS 15" CSP @ 5' SPACING = 86 SLOTS 12" W x 4" H BARRIER SLOT FLOWABLE FILLFILL WITH 2GI RCP-IV 15" 2GI RCP-IV 15" +81.6 BEG. SBG +10.8 END SBG 15" RCP-IV 15" RCP-IV EST 10 SY GF EST 4 TONS EST 9 SY CLASS I RIP RAP 15" CSP w/ELBOWSw/ELBOWS15" CSP 15" RCP-IV 15" R CP-IV 15" RCP-IVDETAIL 16-6 SEE SHEET 2D-1 SPECIAL CUT DITCH DETAIL 16-6 SEE SHEET 2D-1 SPECIAL CUT DITCH EST 7 SY GF EST 2 TONS CLASS B RIP RAP DETAIL 16-5 SEE SHEET 2D-1 SPECIAL CUT DITCH DETAIL 16-8 SEE SHEET 2D-1 W/ CLASS B RIP RAP SPECIAL CUT DITCH EST 7 SY GF EST 2 TONS CLASS B RIP RAP W/E L BOWS 18" CS P CB DETAIL 16-11 SEE SHEET 2D-1 TOE PROTECTION 53 54 59 58 57 56 55 60 61 53 141 142 143 144 145 146 147 70 151 51 53 140 WB WB WJ PERENNIAL SF- INTERMIT SD- INTERMITTENT SF- INTERMITTENT SF- PERENNIAL SF- SITE 6 SITE 6 SITE 7 SITE 15 -L- STA. 198+15 LT D10= 2.2 ft V10= 2.6 fps Q10= 65 cfs D2= 1.9 ft V2= 2.4 fps Q2= 48 cfs SLOPE= 0.44% DA= 59.0 ac STANDARD BASE DITCH DATA -CD1- STA. 15+78 TO STA. 25+00 LT D10= 3.4 ft V10= 1.8 fps Q10= 88 cfs D2= 3.2 ft V2= 1.7 fps Q2= 74 cfs SLOPE= 0.13% DA= 32.0 ac SPECIAL CUT BASE DITCH DATA FINAL DESIGN. 4B/4C AND MAY CHANGE WITH DESIGN CONCEPT USED FOR SITE 7 IS PRELIMINARY DESIGN. NOTE: SITE 8 BSTWOODS72" CHLSR 1770 SUNSET AVE 25' PAVED ROADWAY 3' PAVED SHOULDERWOODS WOODSWOODS 48" WW 1-SBW48" WW 1-SBWPDEPDE R/W MONJLR REAL ESTATE, LLC EXI STI NG R/WEIPEXISTING R/W 150' CP&L EASEMENT ; ;;20' UTILITY EASEMENT 20' UTILITY EASEMENT 139 12" DIP12" VCP12" DIP 12" VCP 12" VCP4" PVC (SERVICE)10" VCP 54" RCP CURB INLET CURB INLET 8" C MP 36" RCP FESLT6" PLASTIC 6" PLASTIC HH 24" DI 6" DI 8" DI 24" DI 60.00' MTLCONC HWCONC HW4' WW4' WWUNKNOWN EASEMENTSHEET __ OF __ PERMIT DRAWING LEGEND NAD 83/ 2011GRAPHIC SCALE 0 252512.5 50 HYDRAULICSROADWAY DESIGN ENGINEER ENGINEER R/W SHEET NO. SHEET NO.PROJECT REFERENCE NO. INCOMPLETE PLANS DO NOT USE FOR R/W ACQUISITION REVISIONS PENTABLE:FILE:\USER:NWOMACKDATE:8/21/2020NCDOT_pdf_color_eng_100.pltPLOT DRIVER:12:06:13 PMTIME:NCDOT_permits_NOCON.tbl16AU-5026 /R-5720 DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED HDR Engineering, Inc. of the Carolinas N.C.B.E.L.S. License Number: F-0116 555 Fayetteville St, Suite 900 Raleigh, N.C. 27601 -L- STA. 198+15 LT D10= 2.2 ft V10= 2.6 fps Q10= 65 cfs D2= 1.9 ft V2= 2.4 fps Q2= 48 cfs SLOPE= 0.44% DA= 59.0 ac STANDARD BASE DITCH DATA F F F F F F F C C F F CRCR CRCR 35-CD1- POT Sta. 32+47.77 -L- POT Sta. 189+80.08 = -L2SB- POT Sta. 42+95.65 -L- POT Sta. 190+49.42 = -RAB6- POC Sta. 14+07.73 -Y15- POT Sta. 19+41.79 =18515 -Y15- PT Sta. 19+23.70 -Y15- PC Sta. 14+18.61 -L- PT Sta. 187+10.33 -L- PRC Sta. 185+83.86 -L- PRC Sta. 184+80.64 -Y15- PRC Sta. 18+49.83 -DRIVE2- POT Sta. 10+00.00 = -Y15- Sta. 17+64.53 -LLPC- ST Sta. 10+00.00 = -CD1- Sta. 32+05.59, 12' LT 40'RS S SURFACE WATER DENOTES IMPACTS IN TS TS IMPACTS IN SURFACE WATER DENOTES TEMPORARY CB CB HW CB CB HW CB CB 15" RCP-IV 15" RCP-IV 15" RCP-IV EST 62 SY GF EST 33 TONS EST 60 SY CLASS I RIP RAP 54" RCP-IV CB (BURIED 1.0') 60" RCP-IV EST 10 SY GF EST 3 TONS CLASS B RIP RAP 18" R C P-I V DETAIL 16-1 SEE SHEET 2D-1 CHANNEL RELOCATION 2GI-A 30" RCP-IV15" RCP-IV RCP-IV 15" w/MH JB 54" RCP-IV @ 5' SPACING = 86 SLOTS 12" W x 4" H BARRIER SLOT 2GI RCP-IV 15" +81.6 BEG. SBG EST 10 SY GF EST 4 TONS EST 9 SY CLASS I RIP RAP w/ELBOWS15" CSP 15" R C P-I V DETAIL 16-5 SEE SHEET 2D-1 SPECIAL CUT DITCH DETAIL 16-8SEE SHEET 2D-1W/ CLASS B RIP RAPSPECIAL CUT DITCH EST 7 SY GF EST 2 TONS CLASS B RIP RAP CB 146 INTERMITTENT SF- INTERMITTENT SF- SITE 6 WOODS SR 1770 SUNSET AVE 25' PAVED ROADWAY 3' PAVED SHOULDERWOODSWOODS48" WW 1-SBW48" WW 1-SBW R/W MONEXISTING R/WEXISTING R/W;;20' UTILITY EASEMENT 12" RCP 12" RCP 36" RCPFES6" PLASTIC 6" PLASTIC 6" DI 24" DI 12" RCP 3MR LIMITED PARTNERSHIP SHEET __ OF __ PERMIT DRAWING LEGEND NAD 83/ 2011GRAPHIC SCALE 0 252512.5 50 TS HYDRAULICSROADWAY DESIGN ENGINEER ENGINEER R/W SHEET NO. SHEET NO.PROJECT REFERENCE NO. INCOMPLETE PLANS DO NOT USE FOR R/W ACQUISITION REVISIONS PENTABLE:FILE:Barnhill_Contracting_Corp\Barnhill-Rocky_Mount_DB\6.0_CAD_BIM\6.2_WIP\Hydraulics\PERMITS_Environmental\Drawings\U5026-R5720_HYD_PRM_WET_PSH.dgnUSER:NWOMACKDATE:8/4/2020NCDOT_pdf_color_eng_100.pltPLOT DRIVER:1:48:03 PMTIME:NCDOT_permits_NOCON.tbl16BU-5026 /R-5720 DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED HDR Engineering, Inc. of the Carolinas N.C.B.E.L.S. License Number: F-0116 555 Fayetteville St, Suite 900 Raleigh, N.C. 27601 C F C F F F F CR -CD2- POT Sta. 37+91.78 -L- POT Sta. 192+03.19 = -RAB7- PC Sta. 12+80.52 -L- POC Sta. 197+43.15 = 12.00' RT. -CD2- POT Sta. 38+04.00, -LLPD- ST Sta. 10+00.00 =195-L- PC Sta. 194+53.21 -L- Sta. 195+72.57 = -RAB7- Sta. 10+00.00 = -RAB7- Sta. 15+34.07 Sta. 198+02.71 -L- PT -L2NB- POT Sta. 43+02.34 -L- POT Sta. 191+33.84 =NAD 83/ 2011S S SURFACE WATER DENOTES IMPACTS IN TS TS IMPACTS IN SURFACE WATER DENOTES TEMPORARY CB CB CB CB CB 18" RCP-I V 18" RCP-IV 15" RCP-IV 15" RCP-IV (BURIED 1.0') 60" RCP-IV DETAIL 16-2 SEE SHEET 2D-1 CHANNEL RELOCATION EST 54 SY GF EST 36 TONS CLASS I RIP RAP BANK STABILIZATION JB w/MH 2GI RCP-IV 15"+10.8 END SBG DETAIL 16-11 SEE SHEET 2D-1 TOE PROTECTION 151 PERENNIAL SF- INTERMIT SD- SITE 6 SITE 7 -L- STA. 198+15 LT SITE 8 30" C&G 30" C&G 30" C&G 30" C&G 30" C&G 30" C&G 30" C&G CONC CONC CONC CONC CONC CONC CONC CONC CONC CONC CONC CONCCONC CONC CONC CONC 30" C&G 30" C&G 12' GR 12' GR 12' GR GR GR GR HOUSE PUMP CONC 1SFD HTR GARAGE CANOPY MTL CEMETERY WOODS WOODS WOODS S48" CHLWOODSDECKHTR CANOPYMTLGR 10' DECK HTR WOODS 1SFD SR 1770 SUNSET AVE 36' PAVED ROADWAY GR HTR DECK DECK CANOPY MTL S S S CANOPY MTL 48" CHL 48" CHL CHL 48" 48" CHL GATE 1SBLKD CONC CONC CONC CANOPY MTL DECK DECK HTR B GR BST BST F BUS BUS BK ABAND 1SFD 1SFD GARAGE 11' GR 11' GR GR 1SBKD S HOUSE PUMP GR CANOPY MTL 1SFD 1SFD S GR GR 10 ' GR 12 ' FENCE 72" WD FENCE 48" WD WD RAMP 2 4 " GUTTER2 4 " GUTTERSUNSHI NE DRI VE 1 8' P AVED ROADWAYBS T2 3' 2 4 " GUTTERBS TSUNSHINE DRIVE 32' PAVED ROADWAYSS CONC DECKGR GR 14 ' PDE PDE ANGELYN EZZELL J.W. HOUSE, ET UX STONY CREEK CEMETERY ASSOCIATION MARK S. BASS DB 2439 PG 456 24' ACCESS EASEMENT 109 110 114 EIP EIP R/W MON R/W MON EXISTING R/W EI PEIP R/W MON R/W MON EIP EIP EIP EIP EIP EIP EIP EIP EIP EIP EIP EXISTING R/W EXISTING R/W EXISTING R/W EXISTING R/W EXISTING R/W EXISTING R/W WHITLEY, ET UX NORMAN O. WHITLEY, ET UX NORMAN O. ANGELYN EZZELL ;;2 0' UT IL ITY EASEMEN T 20 ' UTILITY EASEMENT SOIL 20' BST 16' GR 14' CHL 48" CONC 18' CONC 16' W /LT W/LT W/LT CO N C 15 " RC P 15" RCP 15" RCP 15" RCP CB CB 15" RCPCB 18" RCP 18" RCP CB RCP15" 18" RCP DI CB 24" RCP 15" RCPDI18" RCPLT LT LT LT TTT T C HH 6" PLASTIC 6" PLAST IC T SIZE UNKNOWN24" DI 8" PVC 8 " P VC2 4 " D I24" DI DUCT BANK DUCT BANK DUCT BANK DUCT BANK EXISTING R/W48" CHLR/W MON 60.00'RCP 15" WALTER L. WILLIAMS 3MR LIMITED PARTNERSHIP JAMES S. LIVERMON, III, ET UX DORIS HINTON COOLEY, ET AL 114 RUBY B. COOLEY HEIRS MOMEYER PROPERTIES, LLC 109 DEBBIE J. JONES DANIEL, ET UX ALTON E. NAD 83/ 2011LEGEND SHEET __ OF __ PERMIT DRAWING GRAPHIC SCALE 0 252512.5 50 17 SEE SHEET 35 & 36 FOR -L- PROFILESEE SHEET 16MATCHLINE -L- STA. 199+00,SEE SHEET 18MATCHLINE -L- STA. 211+00.00,HYDRAULICSROADWAY DESIGN ENGINEER ENGINEER R/W SHEET NO. SHEET NO.PROJECT REFERENCE NO. INCOMPLETE PLANS DO NOT USE FOR R/W ACQUISITION REVISIONS PENTABLE:FILE:Barnhill_Contracting_Corp\Barnhill-Rocky_Mount_DB\6.0_CAD_BIM\6.2_WIP\Hydraulics\PERMITS_Environmental\Drawings\U5026-R5720_HYD_PRM_WET_PSH.dgnUSER:NWOMACKDATE:6/24/2020NCDOT_pdf_color_eng_100.pltPLOT DRIVER:9:28:28 AMTIME:NCDOT_permits_NOCON.tblDOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED HDR Engineering, Inc. of the Carolinas N.C.B.E.L.S. License Number: F-0116 555 Fayetteville St, Suite 900 Raleigh, N.C. 27601 U-5026 / R-5720 F F F F F F C F F F F F F F F F FF C C F F F F F F F F C C R CR-RAB7 - PC S ta . 12+80 .52-L - POC S ta . 197+43 .15 =200205210-L- PC Sta. 206+21.34 NAD 83/ 2011BARNHILL CONTRACTING COMPANY CLEARING DENOTES MECHANIZED* * * * ** * ** * * CB CB CB CB CB DI CB DI CB DI CB CB 15" RCP-IV 15" RCP-IV EST 5 SY GF EST 1 TONS CLASS B RIP RAP EST 7 SY GF EST 2 TONS CLASS B RIP RAP FOR PROPOSAL UNLESS OTHERWISE NOTED ON THE PLANS. RIGHT-OF-WAY SHALL BE REMOVED AS DESCRIBED IN THE REQUEST ALL EXISTING DRAINAGE STRUCTURES AND PIPES WITHIN PROJECT CB 18" RCP-IV 15" RCP-IV 18" RCP-IV 18" RCP-IV 24" RCP-IV 24" RCP -IVRCP-IV 15" 15" RCP-IV 18" RCP-IV DIDIRCP-IV 15" DI DI DIW/ELBOWS18" CSPDI DI 15" RCP-IV RCP-IV 15" RCP-IV 15" RCP-IV 15"DI DI DI DI DI DI DI RCP-IV 15" RCP-IV 15" RCP-IV 15" 15" RCP-IV 15" RCP-IV 15" RCP-IV 15" RCP-IV CB RCP-IV 18" RCP-IV 15" DI CB 15" RCP-IV RCP-IV 18" 18" RCP-IV 15" RCP-IV (NON-EROSIVE) V10=1.2 fps Q10=5.4 cfs 70 71 72 73 74 76 75 152 153 154 155 156 157 151 72 73 76 77 77 PERENNIAL SF- WBA SITE 8 30" C&G 30" C&G 30" C&G 30" C&G 30" C&G 30" C&G 30" C&G CONC CONC CONC CONC CONC CONC CONC CONC CONC CONC CONC CONCCONC CONC CONC CONC 30" C&G 30" C&G 12' GR 12' GR 12' GR GR GR GR HOUSE PUMP CONC 1SFD HTR GARAGE CANOPY MTL CEMETERY WOODS WOODS WOODS S48" CHLWOODSDECKHTR CANOPYMTLGR 10' DECK HTR WOODS 1SFD SR 1770 SUNSET AVE 36' PAVED ROADWAY GR HTR DECK DECK CANOPY MTL S S S CANOPY MTL 48" CHL 48" CHL CHL 48" 48" CHL GATE 1SBLKD CONC CONC CONC CANOPY MTL DECK DECK HTR B GR BST BST F BUS BUS BK ABAND 1SFD 1SFD GARAGE 11' GR 11' GR GR 1SBKD S HOUSE PUMP GR CANOPY MTL 1SFD 1SFD S GR GR 10 ' GR 12 ' FENCE 72" WD FENCE 48" WD WD RAMP 2 4 " GUTTER2 4 " GUTTERSUNSHI NE DRI VE 1 8' P AVED ROADWAYBS T2 3' 2 4 " GUTTERBS TSUNSHINE DRIVE 32' PAVED ROADWAYSS CONC DECKGR GR 14 ' PDE PDE ANGELYN EZZELL J.W. HOUSE, ET UX STONY CREEK CEMETERY ASSOCIATION MARK S. BASS DB 2439 PG 456 24' ACCESS EASEMENT 109 110 114 EIP EIP R/W MON R/W MON EXISTING R/W EI PEIP R/W MON R/W MON EIP EIP EIP EIP EIP EIP EIP EIP EIP EIP EIP EXISTING R/W EXISTING R/W EXISTING R/W EXISTING R/W EXISTING R/W EXISTING R/W WHITLEY, ET UX NORMAN O. WHITLEY, ET UX NORMAN O. ANGELYN EZZELL ;;2 0' UT IL ITY EASEMEN T 20 ' UTILITY EASEMENT SOIL 20' BST 16' GR 14' CHL 48" CONC 18' CONC 16' W /LT W/LT W/LT CO N C 15 " RC P 15" RCP 15" RCP 15" RCP CB CB 15" RCPCB 18" RCP 18" RCP CB RCP15" 18" RCP DI CB 24" RCP 15" RCPDI18" RCPLT LT LT LT TTT T C HH 6" PLASTIC 6" PLAST IC T SIZE UNKNOWN24" DI 8" PVC 8 " P VC2 4 " D I24" DI DUCT BANK DUCT BANK DUCT BANK DUCT BANK EXISTING R/W48" CHLR/W MON 60.00'RCP 15" WALTER L. WILLIAMS 3MR LIMITED PARTNERSHIP JAMES S. LIVERMON, III, ET UX DORIS HINTON COOLEY, ET AL 114 RUBY B. COOLEY HEIRS MOMEYER PROPERTIES, LLC 109 DEBBIE J. JONES DANIEL, ET UX ALTON E. NAD 83/ 2011LEGEND SHEET __ OF __ PERMIT DRAWING GRAPHIC SCALE 0 252512.5 50 17 SEE SHEET 35 & 36 FOR -L- PROFILESEE SHEET 16MATCHLINE -L- STA. 199+00,SEE SHEET 18MATCHLINE -L- STA. 211+00.00,HYDRAULICSROADWAY DESIGN ENGINEER ENGINEER R/W SHEET NO. SHEET NO.PROJECT REFERENCE NO. INCOMPLETE PLANS DO NOT USE FOR R/W ACQUISITION REVISIONS PENTABLE:FILE:Barnhill_Contracting_Corp\Barnhill-Rocky_Mount_DB\6.0_CAD_BIM\6.2_WIP\Hydraulics\PERMITS_Environmental\Drawings\U5026-R5720_HYD_PRM_WET_PSH.dgnUSER:NWOMACKDATE:6/24/2020NCDOT_pdf_color_eng_100.pltPLOT DRIVER:9:34:07 AMTIME:NCDOT_permits_CON.tblDOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED HDR Engineering, Inc. of the Carolinas N.C.B.E.L.S. License Number: F-0116 555 Fayetteville St, Suite 900 Raleigh, N.C. 27601 U-5026 / R-5720 150150150150 155155155155155 155 155 155 155155155155160160160 160160 160160160160160160160160 160 160160160160160160160160160160160 160 160160 160160 160160165165165165 165 165 165165165165165165 165165 165170170170 170 170170175175 F F F F F F C F F F F F F F F F FF C C F F F F F F F F C C R CR-RAB7 - PC S ta . 12+80 .52-L - POC S ta . 197+43 .15 =200205210-L- PC Sta. 206+21.34 NAD 83/ 2011BARNHILL CONTRACTING COMPANY CLEARING DENOTES MECHANIZED* * * * ** * ** * * CB CB CB CB CB DI CB DI CB DI CB CB 15" RCP-IV 15" RCP-IV EST 5 SY GF EST 1 TONS CLASS B RIP RAP EST 7 SY GF EST 2 TONS CLASS B RIP RAP FOR PROPOSAL UNLESS OTHERWISE NOTED ON THE PLANS. RIGHT-OF-WAY SHALL BE REMOVED AS DESCRIBED IN THE REQUEST ALL EXISTING DRAINAGE STRUCTURES AND PIPES WITHIN PROJECT CB 18" RCP-IV 15" RCP-IV 18" RCP-IV 18" RCP-IV 24" RCP-IV 24" RCP -IVRCP-IV 15" 15" RCP-IV 18" RCP-IV DIDIRCP-IV 15" DI DI DIW/ELBOWS18" CSPDI DI 15" RCP-IV RCP-IV 15" RCP-IV 15" RCP-IV 15"DI DI DI DI DI DI DI RCP-IV 15" RCP-IV 15" RCP-IV 15" 15" RCP-IV 15" RCP-IV 15" RCP-IV 15" RCP-IV CB RCP-IV 18" RCP-IV 15" DI CB 15" RCP-IV RCP-IV 18" 18" RCP-IV 15" RCP-IV (NON-EROSIVE) V10=1.2 fps Q10=5.4 cfs 70 71 72 73 74 76 75 152 153 154 155 156 157 151 72 73 76 77 77 PERENNIAL SF- WBA SITE 8 CONC BRIDGE CONC BRIDGE WOODS WOODS WOODS CSX RR CSX RR CSX RR WOODS WOODS CONC CONC CONC CONC CONC CONC CONC 48" WW 1-SBW CONC CONC 48" WW 1-SBW 48" WW 1-SBW 48" WW 1-SBW 48" WW 1-SBW CAROLINA COASTAL RAILWAY, INC. MIDATLANTIC WAREHOUSE & STORAGE, LLC MIDATLANTIC WAREHOUSE & STORAGE, LLC TITAN CAROLINA CONCRETE, LLC WILLIAMS GENERAL CONTRACTORS, LLC R/W MON R/W MON R/W MON R/W MONR/W MON EIP WILLIAMS GENERAL CONTRACTORS, LLC EXISTING R/W EXISTING R/W EIP EIP EIP EIP CLIFTON PRICE HARPER, JR.CAROLINA COASTAL RAILWAY, INC. CITY OF ROCKY MOUNT LIMITS ; ; ;; 8" PVC 8" PVC DI15" CMP12" PVC36" RCPFES FES 10" PVC 12" PVCU-5026-1 U-5026-2 CITY OF ROCKY MOUNT LIMITS 12' PAVED SHOULDER 4' PAVED SHOULDER I-95 SBL 24' CONC ROADWAY 4' PAVED SHOULDER I-95 NBL 24' CONC ROADWAY 12' PAVED SHOULDER MTL MTL MTL MTL MTL MTL CABLE CONC CONC CONC CONC 15' PERMANENT UTILITY EASEMENT15' PERMANENT UTILITY EASEMENTUNKNOWN EASEMENT UNKNOWN EASEMENT SUNSET WEST, LLC MICHAEL J. DAVIS, ET UX NAD 83/ 2011 SHEET __ OF __ PERMIT DRAWING LEGEND GRAPHIC SCALE 0 252512.5 50 DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED SEE SHEET 22STA. 12+00.00MATCHLINE -CD1-SEE SHEET 22STA. 18+00.00MATCHLINE -CD2-21 SEE SHEET 40 FOR -CD2- PROFILE SEE SHEET 38 FOR -CD1- PROFILE BRIDGE DECK REHABILITATIONSEE SHEET 20STA. 10+00.00MATCHLINE -L2SB-SEE SHEET 20STA. 10+00.00MATCHLINE -L2NB-HYDRAULICSROADWAY DESIGN ENGINEER ENGINEER R/W SHEET NO. SHEET NO.PROJECT REFERENCE NO. INCOMPLETE PLANS DO NOT USE FOR R/W ACQUISITION REVISIONS PENTABLE:FILE:Barnhill_Contracting_Corp\Barnhill-Rocky_Mount_DB\6.0_CAD_BIM\6.2_WIP\Hydraulics\PERMITS_Environmental\Drawings\U5026-R5720_HYD_PRM_WET_PSH.dgnUSER:NWOMACKDATE:6/24/2020NCDOT_pdf_color_eng_100.pltPLOT DRIVER:9:28:38 AMTIME:NCDOT_permits_NOCON.tblDOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED HDR Engineering, Inc. of the Carolinas N.C.B.E.L.S. License Number: F-0116 555 Fayetteville St, Suite 900 Raleigh, N.C. 27601 U-5026 / R-5720 F F F F F F F F F F F F 1015101520101520-CD2- PC Sta. 17+64.35 D -CD2- POT Sta. 10+00.00 = = 2°55'59.6" -L2NB- POT Sta. 15+18.83, 11.18' RT.1010= 3°00'00.0" -L2SB- POT Sta. 20+40.37, 12.00' LT. -CD1- POC Sta. 10+00.00 = D NAD 83/ 2011 BARNHILL CONTRACTING COMPANY WETLAND DENOTES FILL IN CLEARING DENOTES MECHANIZED* *** *** * F F HC HC CLEARING DENOTES HAND TRENCHLESS INSTALLATION 42" WELDED STEEL FOR PROPOSAL UNLESS OTHERWISE NOTED ON THE PLANS. RIGHT-OF-WAY SHALL BE REMOVED AS DESCRIBED IN THE REQUEST ALL EXISTING DRAINAGE STRUCTURES AND PIPES WITHIN PROJECT HW 2GITRENCHLESS INSTALLATION 15" WELDED STEELEST 7 SY GF EST 2 TONS CLASS B RIP RAP FILL WITH FLOWABLE FILL FILL WITH FLOWABLE FILL EST 30 SY GF EST 13 TONS EST 22 SY CLASS I RIP RAP DETAIL 21-1 SEE SHEET 2D-1 TOE PROTECTION DETAIL 21-1 SEE SHEET 2D-1 TOE PROTECTION DETAIL 21-1 SEE SHEET 2D-1 TOE PROTECTION DETAIL 21-2 SEE SHEET 2D-1 FS (NON-EROSIVE) V10=1.9 fps Q10=41.0 cfs 51 62 62 63 65 66 67 68 WI WN WP WK WO WT WL SITE 10 SITE 9 SITE 11 SITE 12 (NON-EROSIVE) V10= 1.9 fps Q10= 41.0 cfs SITE 14 CONC BRIDGE CONC BRIDGE WOODS WOODS WOODS CSX RR CSX RR CSX RR WOODS WOODS CONC CONC CONC CONC CONC CONC CONC 48" WW 1-SBW CONC CONC 48" WW 1-SBW 48" WW 1-SBW 48" WW 1-SBW 48" WW 1-SBW CAROLINA COASTAL RAILWAY, INC. MIDATLANTIC WAREHOUSE & STORAGE, LLC MIDATLANTIC WAREHOUSE & STORAGE, LLC TITAN CAROLINA CONCRETE, LLC WILLIAMS GENERAL CONTRACTORS, LLC R/W MON R/W MON R/W MON R/W MONR/W MON EIP WILLIAMS GENERAL CONTRACTORS, LLC EXISTING R/W EXISTING R/W EIP EIP EIP EIP CLIFTON PRICE HARPER, JR.CAROLINA COASTAL RAILWAY, INC. CITY OF ROCKY MOUNT LIMITS ; ; ;; 8" PVC 8" PVC DI15" CMP12" PVC36" RCPFES FES 10" PVC 12" PVCU-5026-1 U-5026-2 CITY OF ROCKY MOUNT LIMITS 12' PAVED SHOULDER 4' PAVED SHOULDER I-95 SBL 24' CONC ROADWAY 4' PAVED SHOULDER I-95 NBL 24' CONC ROADWAY 12' PAVED SHOULDER MTL MTL MTL MTL MTL MTL CABLE CONC CONC CONC CONC 15' PERMANENT UTILITY EASEMENT15' PERMANENT UTILITY EASEMENTUNKNOWN EASEMENT UNKNOWN EASEMENT SUNSET WEST, LLC MICHAEL J. DAVIS, ET UX NAD 83/ 2011 SHEET __ OF __ PERMIT DRAWING LEGEND GRAPHIC SCALE 0 252512.5 50 DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED SEE SHEET 22STA. 12+00.00MATCHLINE -CD1-SEE SHEET 22STA. 18+00.00MATCHLINE -CD2-21 SEE SHEET 40 FOR -CD2- PROFILE SEE SHEET 38 FOR -CD1- PROFILE BRIDGE DECK REHABILITATIONSEE SHEET 20STA. 10+00.00MATCHLINE -L2SB-SEE SHEET 20STA. 10+00.00MATCHLINE -L2NB-HYDRAULICSROADWAY DESIGN ENGINEER ENGINEER R/W SHEET NO. SHEET NO.PROJECT REFERENCE NO. INCOMPLETE PLANS DO NOT USE FOR R/W ACQUISITION REVISIONS PENTABLE:FILE:Barnhill_Contracting_Corp\Barnhill-Rocky_Mount_DB\6.0_CAD_BIM\6.2_WIP\Hydraulics\PERMITS_Environmental\Drawings\U5026-R5720_HYD_PRM_WET_PSH.dgnUSER:NWOMACKDATE:6/24/2020NCDOT_pdf_color_eng_100.pltPLOT DRIVER:9:34:11 AMTIME:NCDOT_permits_CON.tblDOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED HDR Engineering, Inc. of the Carolinas N.C.B.E.L.S. License Number: F-0116 555 Fayetteville St, Suite 900 Raleigh, N.C. 27601 U-5026 / R-5720 160 16 0 1601 6 0 160 160160160160 160160160 160160160160 160160160160160160160 160 160160 160160 1601 6 0 160160 160160160160 160 160 160 1601601 6 0 160 1601 60 160 160160 160 1601 6 0 1 60 1601601601 6 016016016016016016016016016 01601 60 1 6 01 60 1 6 0165165 165165165165165165165165165165165165165165165165165165165 165165 165 165 165 165 1651651651651 6 5 165170170170170170170170170170170170170170 170170170170170170170170170170170170175175175175175175175175175 175175175175175175175175175175175175175175180180180180180180180180180180 180180 180 180180180180 180180180180180180180180180180180180185185185185185185185185185185185 185 185 185185185185185185185185185185 185185 185 185 185 185 190 190 190 1901901901901901 9 0 190190F F F F F F F F F F F F 1015101520101520-CD2- PC Sta. 17+64.35 D -CD2- POT Sta. 10+00.00 = = 2°55'59.6" -L2NB- POT Sta. 15+18.83, 11.18' RT.1010= 3°00'00.0" -L2SB- POT Sta. 20+40.37, 12.00' LT. -CD1- POC Sta. 10+00.00 = D NAD 83/ 2011 BARNHILL CONTRACTING COMPANY WETLAND DENOTES FILL IN CLEARING DENOTES MECHANIZED* *** *** * F F HC HC CLEARING DENOTES HAND TRENCHLESS INSTALLATION 42" WELDED STEEL FOR PROPOSAL UNLESS OTHERWISE NOTED ON THE PLANS. RIGHT-OF-WAY SHALL BE REMOVED AS DESCRIBED IN THE REQUEST ALL EXISTING DRAINAGE STRUCTURES AND PIPES WITHIN PROJECT HW 2GITRENCHLESS INSTALLATION 15" WELDED STEELEST 7 SY GF EST 2 TONS CLASS B RIP RAP FILL WITH FLOWABLE FILL FILL WITH FLOWABLE FILL EST 30 SY GF EST 13 TONS EST 22 SY CLASS I RIP RAP DETAIL 21-1 SEE SHEET 2D-1 TOE PROTECTION DETAIL 21-1 SEE SHEET 2D-1 TOE PROTECTION DETAIL 21-1 SEE SHEET 2D-1 TOE PROTECTION DETAIL 21-2 SEE SHEET 2D-1 FS (NON-EROSIVE) V10=1.9 fps Q10=41.0 cfs 51 62 62 63 65 66 67 68 WI WN WP WK WO WT WL SITE 10 SITE 9 SITE 11 SITE 12 (NON-EROSIVE) V10= 1.9 fps Q10= 41.0 cfs SITE 14 WETLANDS 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120120 120120 130130 130130 140140 140140 150150 1501508/23/99PROJ. REFERENCE NO.SHEET NO.0 PENTABLE:FILE:U5026_R5720_PRM_XPL_CD2USER:_USERNAME_DATE:5/21/2020NCDOT_pdf_color_eng_100.pltPLOT DRIVER:12:59:39 PMTIME:NCDOT_PFL_XSC.tbl160 160 170 170 180 180 190 190 150 150 10+00.00 160 160 170 170 180 180 190 190 150 150 10+50.00 160 160 170 170 180 180 190 190 150 150 11+00.00 X-143U-5026/R-5720 -CD2- 5 10 PERMIT SITE 9 U-5026 SHEET __ OF __ PERMIT DRAWING 0.0250.0250.025 189.05 3:10.025 0.0250.025 188.89 3:10.025 0.0250.034 188.58 3:10.025 WETLANDS 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120120 120120 130130 130130 140140 140140 150150 1501508/23/99PROJ. REFERENCE NO.SHEET NO.0 PENTABLE:FILE:U5026_R5720_PRM_XPL_L2SBUSER:_USERNAME_DATE:5/21/2020NCDOT_pdf_color_eng_100.pltPLOT DRIVER:1:09:00 PMTIME:NCDOT_PFL_XSC.tbl160 160 170 170 180 180 190 190 150 150 15+00.00 160 160 170 170 180 180 190 190 150 150 15+50.00 160 160 170 170 180 180 190 190 150 150 16+00.00 X-114U-5026/R-5720 -L2SB- 5 10 PERMIT SITE 12 U-5026 SHEET __ OF __ PERMIT DRAWING 3:1 0.0250.025 6 :1 190.50 3:1 0.0250.025 6 :1 190.40 3:1 0.0250.025 6 :1 190.17 24" C&G24" C&GCONCBUNCH CIRCLE 15' GR HTR CONC DECK WOODS 48" WW 1-SBW 48" WW 1-SBW BILLBOARD BILLBOARD HTR HTR HTR HTR HTR HTR HTR GR GR GR GR GR GR BANNER WAY 15' PAVED ROADWAY DECK DECK DECK DECK DECK DECK DECK DECK CUTOVER WOODS WOODS SUNSHINE DRIVE 18' PAVED ROADWAYSSSSDECKCONCHTRHTRHTRHTRHTRHTRDECKDECKDECKDECKDECKDECKDECKDECKDECKDECKDECKDECKDECKHTR1SFDSHELTERHTRCONCDECKGR 24" GUTTER24" GUTTER24" GUTTER24" GUTTER24" GUTTERCONCDECK72" WD FENCE 48" WD FENCECONC18'CONC26'CONC18'CONC18'CONC18'CONC18'CONC10' CONC10' RAINBOW LANE 18' PAVED ROADWAYCONC30'HTRRAINBOW LANE 18' PAVED ROADWAYWOODS WOODS CONC METERPWRMETERPWRMETERPWRMETERPWRMETERPWRMETERPWRMETERPWRMETERPWRMETERPWRMETERPWRMETERPWRMETERPWRMETERPWRMETERPWRSUNSET WEST, LLC SUNSET WEST, LLC WILLIAMS GENERAL CONTRACTORS, LLC R/W MON EXISTING R/W EXISTING R/W EIP EIP VARIES150' CP&L EASEMENTCITY OF ROCKY MOUNT LIMITS CI TY OF ROCKY MOUNT LIMI TSCI TY OF ROCKY MOUNT LI MI TS; ;24" GUTTER24" GUTTERFENCE48" WD 24" GUTTER24" GUTTER24" GUTTERDECKSCONCCONCCONCCONCCONCMETERPWRMETERPWRMETERPWRMETERPWRMETERPWRMETERPWRCONC48" WW 1-SBW 48" WW 1-SBW 8" PVC8" PVC8" PVC8" PVC 8" PVC8" PVC8" PVC DI 15" RCPFES DI 18" RCPDI 15" RCP8" PVC 8" PVC8" PVC8" PVC 8" PVC 8" P VC FES (DETACHED) MH UNDER STEPS FOR HTR (TYP)WATER TAP FOR HTR (TYP)WATER TAP FOR HTR (TYP)WATER TAP FOR HTR (TYP)WATER TAP 36" RCPLTLTLTLTCTCTCTTCTCTCTC4" PVC 4" P V C 8" PVC8" PVC6" PVCPVC6"6" PVC6" PVCPVC6"6" PVCCONC LIMITS CITY OF ROCKY MOUNT (TYP)FOR HTR WATER TAP METERPWRMETERPWRMETERPWRMETERPWRI-95 SBL I-95 NBL MTL20' UTILITY EASEMENT18' PAVED ROADWAYWEST TOWER LANENAD 83/ 2011 SHEET __ OF __ PERMIT DRAWING LEGEND GRAPHIC SCALE 0 252512.5 50 SEE SHEET 21STA. 12+00.00MATCHLINE -CD1-SEE SHEET 21STA. 18+00.00MATCHLINE -CD2-SEE SHEET 16STA. 16+00.00MATCHLINE -LRPC-SEE SHEET 16STA. 25+00.00MATCHLINE -CD1-SEE SHEET 16STA. 30+00.00MATCHLINE -CD2-SEE SHEET 16STA. 15+00.00MATCHLINE -LRPD-22 SEE SHEET 43 FOR -LRPD- PROFILE SEE SHEET 42 FOR -LRPC- PROFILE SEE SHEET 40 FOR -CD2- PROFILE SEE SHEET 38 FOR -CD1- PROFILE HYDRAULICSROADWAY DESIGN ENGINEER ENGINEER R/W SHEET NO. SHEET NO.PROJECT REFERENCE NO. INCOMPLETE PLANS DO NOT USE FOR R/W ACQUISITION REVISIONS PENTABLE:FILE:Barnhill_Contracting_Corp\Barnhill-Rocky_Mount_DB\6.0_CAD_BIM\6.2_WIP\Hydraulics\PERMITS_Environmental\Drawings\U5026-R5720_HYD_PRM_WET_PSH.dgnUSER:NWOMACKDATE:6/24/2020NCDOT_pdf_color_eng_100.pltPLOT DRIVER:9:28:48 AMTIME:NCDOT_permits_NOCON.tblDOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED HDR Engineering, Inc. of the Carolinas N.C.B.E.L.S. License Number: F-0116 555 Fayetteville St, Suite 900 Raleigh, N.C. 27601 U-5026 / R-5720 F C F C C F C C C C CF F F C C C C C CCC C C F C C F C 152025202530253035253035-L2SB- PT Sta. 33+56.74 -L2SB- PC Sta. 23+11.61 -CD1- PT Sta. 18+06.77 30251515-LRPC- CS Sta. 16+09.73-LRPC- ST Sta. 10+00.00 = -LRPC- SC Sta. 12+56.00 -CD2- PT Sta. 24+45.03 -LR[D- SC Sta. 15+02.23-LRPD- POT Sta. 10+00.00 = -LRPD- TS Sta. 12+46.23 15= 3°00'00.0" -CD2- Sta. 25+04.89, 12' RT D -CD1- Sta. 19+26.58, 12' LT NAD 83/ 2011 BARNHILL CONTRACTING COMPANY WETLAND DENOTES FILL IN CLEARING DENOTES MECHANIZED* *** *** * F F E E IN WETLAND DENOTES EXCAVATION HC HC CLEARING DENOTES HAND S S SURFACE WATER DENOTES IMPACTS IN 2GI 2GI TRENCHLESS INSTALLATION 48" WELDED STEEL EST 50 SY GF EST 26 TONS EST 49 SY CLASS I RIP RAP EST 10 SY GF EST 3 TONS CLASS B RIP RAP EST 14 SY GF EST 5 TONS CLASS B RIP RAP FOR PROPOSAL UNLESS OTHERWISE NOTED ON THE PLANS. RIGHT-OF-WAY SHALL BE REMOVED AS DESCRIBED IN THE REQUEST ALL EXISTING DRAINAGE STRUCTURES AND PIPES WITHIN PROJECT HW RETAIN RETAIN RETAIN 2GI 15" RCP-IV FILL WITH FLOWABLE FILL EST 20 SY GF EST 15 TONS CLASS 1 RIP RAPEST 20 SY GF EST 15 TONS CLASS I RIP RAP SEE DETAIL 22-1 EST 19 SY GF EST 14 TONS CLASS 'I' RIP RAP RIP RAP AT EMBANKMENT 24" RCP-IVEST. 5 TONS CLASS B RIP RAP EST 14 SY GF24" RCP-IV2GI 18" R CP-IV LATERAL BASE DITCH DETAIL 22-4 DETAIL 22-7 SEE SHEET 2D-1 SPECIAL CUT BASE DITCH DETAIL 22-2 SEE SHEET 2D-1 LATERAL V DITCH DETAIL 22-7 SEE SHEET 2D-1 SPECIAL CUT BASE DITCH DETAIL 21-1 SEE SHEET 2D-1 TOE PROTECTION DETAIL 22-6 SEE SHEET 2D-1 TOE PROTECTION DETAIL 16-5 SEE SHEET 2D-1 SPECIAL CUT DITCH SEE SHEET 2D-1 DETAIL 22-3 SEE SHEET 2D-1 LATERAL BASE DITCH DETAIL 22-8 SEE SHEET 2D-1 FS DETAIL 22-8 SEE SHEET 2D-1 FS DETAIL 22-8 SEE SHEET 2D-1 FS DETAIL 22-8 SEE SHEET 2D-1 FS DETAIL 22-5 SEE SHEET 2D-1 SPECIAL CUT BASE BERM DITCH EST 6 SY GF EST 2 TONS EST 3 SY CLASS I RIP RAP 53 68 69 WT WB WL WT WT INTERMITTENT SE- SITE 15 SITE 14 SITE 13 -CD2- STA. 20+00 RT D10= 2.9 ft V10= 1.8 fps Q10= 50 cfs D2= 2.6 ft V2= 1.7 fps Q2= 36 cfs SLOPE= 0.30% DA= 69.5 ac SPECIAL LAT. BASE DITCH DATA SITE 12 24" C&G24" C&GCONCBUNCH CIRCLE 15' GR HTR CONC DECK WOODS 48" WW 1-SBW 48" WW 1-SBW BILLBOARD BILLBOARD HTR HTR HTR HTR HTR HTR HTR GR GR GR GR GR GR BANNER WAY 15' PAVED ROADWAY DECK DECK DECK DECK DECK DECK DECK DECK CUTOVER WOODS WOODS SUNSHINE DRIVE 18' PAVED ROADWAYSSSSDECKCONCHTRHTRHTRHTRHTRHTRDECKDECKDECKDECKDECKDECKDECKDECKDECKDECKDECKDECKDECKHTR1SFDSHELTERHTRCONCDECKGR 24" GUTTER24" GUTTER24" GUTTER24" GUTTER24" GUTTERCONCDECK72" WD FENCE 48" WD FENCECONC18'CONC26'CONC18'CONC18'CONC18'CONC18'CONC10' CONC10' RAINBOW LANE 18' PAVED ROADWAYCONC30'HTRRAINBOW LANE 18' PAVED ROADWAYWOODS WOODS CONC METERPWRMETERPWRMETERPWRMETERPWRMETERPWRMETERPWRMETERPWRMETERPWRMETERPWRMETERPWRMETERPWRMETERPWRMETERPWRMETERPWRSUNSET WEST, LLC SUNSET WEST, LLC WILLIAMS GENERAL CONTRACTORS, LLC R/W MON EXISTING R/W EXISTING R/W EIP EIP VARIES150' CP&L EASEMENTCITY OF ROCKY MOUNT LIMITS CI TY OF ROCKY MOUNT LIMI TSCI TY OF ROCKY MOUNT LI MI TS; ;24" GUTTER24" GUTTERFENCE48" WD 24" GUTTER24" GUTTER24" GUTTERDECKSCONCCONCCONCCONCCONCMETERPWRMETERPWRMETERPWRMETERPWRMETERPWRMETERPWRCONC48" WW 1-SBW 48" WW 1-SBW 8" PVC8" PVC8" PVC8" PVC 8" PVC8" PVC8" PVC DI 15" RCPFES DI 18" RCPDI 15" RCP8" PVC 8" PVC8" PVC8" PVC 8" PVC 8" P VC FES (DETACHED) MH UNDER STEPS FOR HTR (TYP)WATER TAP FOR HTR (TYP)WATER TAP FOR HTR (TYP)WATER TAP FOR HTR (TYP)WATER TAP 36" RCPLTLTLTLTCTCTCTTCTCTCTC4" PVC 4" P V C 8" PVC8" PVC6" PVCPVC6"6" PVC6" PVCPVC6"6" PVCCONC LIMITS CITY OF ROCKY MOUNT (TYP)FOR HTR WATER TAP METERPWRMETERPWRMETERPWRMETERPWRI-95 SBL I-95 NBL MTL20' UTILITY EASEMENT18' PAVED ROADWAYWEST TOWER LANENAD 83/ 2011 SHEET __ OF __ PERMIT DRAWING LEGEND GRAPHIC SCALE 0 252512.5 50 SEE SHEET 21STA. 12+00.00MATCHLINE -CD1-SEE SHEET 21STA. 18+00.00MATCHLINE -CD2-SEE SHEET 16STA. 16+00.00MATCHLINE -LRPC-SEE SHEET 16STA. 25+00.00MATCHLINE -CD1-SEE SHEET 16STA. 30+00.00MATCHLINE -CD2-SEE SHEET 16STA. 15+00.00MATCHLINE -LRPD-22 SEE SHEET 43 FOR -LRPD- PROFILE SEE SHEET 42 FOR -LRPC- PROFILE SEE SHEET 40 FOR -CD2- PROFILE SEE SHEET 38 FOR -CD1- PROFILE HYDRAULICSROADWAY DESIGN ENGINEER ENGINEER R/W SHEET NO. SHEET NO.PROJECT REFERENCE NO. INCOMPLETE PLANS DO NOT USE FOR R/W ACQUISITION REVISIONS PENTABLE:FILE:Barnhill_Contracting_Corp\Barnhill-Rocky_Mount_DB\6.0_CAD_BIM\6.2_WIP\Hydraulics\PERMITS_Environmental\Drawings\U5026-R5720_HYD_PRM_WET_PSH.dgnUSER:NWOMACKDATE:6/24/2020NCDOT_pdf_color_eng_100.pltPLOT DRIVER:9:34:16 AMTIME:NCDOT_permits_CON.tblDOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED HDR Engineering, Inc. of the Carolinas N.C.B.E.L.S. License Number: F-0116 555 Fayetteville St, Suite 900 Raleigh, N.C. 27601 U-5026 / R-5720 160160160160160 1 6 0 160160 160 160160160160160 1 6 0 1601 6 0 1 6 0 165 165165 165165 165165 165165165 165165165165165165165165165165165 165 165 165 165 165 165 165165165 1651 6 5 165 165 165 165165165165165165165165165 165 165165 165165165 165 165 165165165 1 6 5 170170 170170170170 170170170170 170 1 7 0 17 0 170 170 1 7 0 170 170170170170170170170170 170 170 170 170170170170170 170 170 170 170 170 170 170 170 170 170 170170170170170170170170170170 170 1701701 7 0 1 7 0170 1701 7 0 1 7 0 175 175 175175175175 175 175 175175175175 175 175175 1 7 5 1 7 5 1 7 5 180180180 180F C F C C F C C C C CF F F C C C C C CCC C C F C C F C 152025202530253035253035-L2SB- PT Sta. 33+56.74 -L2SB- PC Sta. 23+11.61 -CD1- PT Sta. 18+06.77 30251515-LRPC- CS Sta. 16+09.73-LRPC- ST Sta. 10+00.00 = -LRPC- SC Sta. 12+56.00 -CD2- PT Sta. 24+45.03 -LR[D- SC Sta. 15+02.23-LRPD- POT Sta. 10+00.00 = -LRPD- TS Sta. 12+46.23 15= 3°00'00.0" -CD2- Sta. 25+04.89, 12' RT D -CD1- Sta. 19+26.58, 12' LT NAD 83/ 2011 BARNHILL CONTRACTING COMPANY WETLAND DENOTES FILL IN CLEARING DENOTES MECHANIZED* *** *** * F F E E IN WETLAND DENOTES EXCAVATION HC HC CLEARING DENOTES HAND S S SURFACE WATER DENOTES IMPACTS IN 2GI 2GI TRENCHLESS INSTALLATION 48" WELDED STEEL EST 50 SY GF EST 26 TONS EST 49 SY CLASS I RIP RAP EST 10 SY GF EST 3 TONS CLASS B RIP RAP EST 14 SY GF EST 5 TONS CLASS B RIP RAP FOR PROPOSAL UNLESS OTHERWISE NOTED ON THE PLANS. RIGHT-OF-WAY SHALL BE REMOVED AS DESCRIBED IN THE REQUEST ALL EXISTING DRAINAGE STRUCTURES AND PIPES WITHIN PROJECT HW RETAIN RETAIN RETAIN 2GI 15" RCP-IV FILL WITH FLOWABLE FILL EST 20 SY GF EST 15 TONS CLASS 1 RIP RAPEST 20 SY GF EST 15 TONS CLASS I RIP RAP SEE DETAIL 22-1 EST 19 SY GF EST 14 TONS CLASS 'I' RIP RAP RIP RAP AT EMBANKMENT 24" RCP-IVEST. 5 TONS CLASS B RIP RAP EST 14 SY GF24" RCP-IV2GI 18" R CP-IV LATERAL BASE DITCH DETAIL 22-4 DETAIL 22-7 SEE SHEET 2D-1 SPECIAL CUT BASE DITCH DETAIL 22-2 SEE SHEET 2D-1 LATERAL V DITCH DETAIL 22-7 SEE SHEET 2D-1 SPECIAL CUT BASE DITCH DETAIL 21-1 SEE SHEET 2D-1 TOE PROTECTION DETAIL 22-6 SEE SHEET 2D-1 TOE PROTECTION DETAIL 16-5 SEE SHEET 2D-1 SPECIAL CUT DITCH SEE SHEET 2D-1 DETAIL 22-3 SEE SHEET 2D-1 LATERAL BASE DITCH DETAIL 22-8 SEE SHEET 2D-1 FS DETAIL 22-8 SEE SHEET 2D-1 FS DETAIL 22-8 SEE SHEET 2D-1 FS DETAIL 22-8 SEE SHEET 2D-1 FS DETAIL 22-5 SEE SHEET 2D-1 SPECIAL CUT BASE BERM DITCH EST 6 SY GF EST 2 TONS EST 3 SY CLASS I RIP RAP 53 68 69 WT WB WL WT WT INTERMITTENT SE- SITE 15 SITE 14 SITE 13 -CD2- STA. 20+00 RT D10= 2.9 ft V10= 1.8 fps Q10= 50 cfs D2= 2.6 ft V2= 1.7 fps Q2= 36 cfs SLOPE= 0.30% DA= 69.5 ac SPECIAL LAT. BASE DITCH DATA SITE 12 WETLANDS WETLANDS 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120120 120120 130130 130130 140140 140140 150150 1501508/23/99PROJ. REFERENCE NO.SHEET NO.0 PENTABLE:FILE:U5026_R5720_PRM_XPL_CD2USER:_USERNAME_DATE:5/21/2020NCDOT_pdf_color_eng_100.pltPLOT DRIVER:12:58:55 PMTIME:NCDOT_PFL_XSC.tbl160 160 170 170 150 150 24+00.00 160 160 170 170 150 150 24+50.00 160 160 170 170 150 150 25+00.00 160 160 170 170 150 150 25+50.00 160 160 170 170 150 150 26+00.00 X-150U-5026/R-5720 -CD2- 5 10 SHEET __ OF __ PERMIT DRAWING PERMIT SITE 14 U-5026 161.19 3:1 3:13:13:1 161.34 3:1 161.043:1160.89 3:1 3:1 161.403:16:1 6:1 6:1 6:1 164.44 4 .1 7 :1 164.69 6:14.5 7 :1 3:10.025 0.0250.025 162.18 160.893:13:1 0.025 0.0250.025 162.51 161.043:13:1 0.025 0.025 0.025 162.69 161.193:13:1 0.0250.025 0.025 EL. =166.95 ' -LRPD- Sta.10+45.05 162.84 0.025 EL. =169.10 ' -L2NB- Sta.30+67.47 161.343:13:1 0.0250.025 0.0250.027 EL. =167.14 ' -LRPD- Sta.10+94.98 162.52 0.025 EL. =169.03 ' -L2NB- Sta.31+17.47 161.403:13:1 WETLANDS WETLANDS PERMIT SITE 15 U-5026 SHEET __ OF __ PERMIT DRAWING 3:1 4 :1162.43 163.37 4 :1 3:1 163.76 3:14:1 162.90 3:14:13:13:1 164.52 166.69 5.94:16 :1 3:13:1 161.293:13:13:1 161.433:13:13:1 161.643:13:1 161.863:100 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120120 120120 130130 130130 140140 140140 150150 1501508/23/99PROJ. REFERENCE NO.SHEET NO.0 PENTABLE:FILE:U5026_R5720_PRM_XPL_LRPCUSER:_USERNAME_DATE:5/21/2020NCDOT_pdf_color_eng_100.pltPLOT DRIVER:1:01:46 PMTIME:NCDOT_PFL_XSC.tbl160 160 170 170 150 150 15+68.50 160 160 170 170 180 180 150 150 16+00.00 160 160 170 170 150 150 16+50.00 170 170 160 160 17+00.00 170 170 160 16017+50.00 X-173U-5026/R-5720 -LRPC- 5 10 EL. =169.69 ' -CD1- Sta.25+32.85 0.025 0.0250.025 0.080 0.080 0.080 168.27 EL. =169.89 ' -CD1- Sta.25+72.56 0.025 0.0250.025 0.080 0.080 0.080 169.13 0.067 0.068 0.067 170.36 0.052 0.052 0.052 170.76 0.036 0.0360.036 171.56 RAP RIP BRK BUS LOADING DOCK S24" C&G 72" CHL 3-SBW 72" CHL 3-SBW BST BST CONC HOUSE PUMP FLAG POLE CONC WOODS WOODS 48" WW 1-SBW BKT ENTERPRISES, L.P. 3MR LIMITED PARTNERSHIP R/W MON R/W MON EXISTING R/W EXISTING R/W VARIES; DI 15" RCPFES 36" RCPFES FES DI24" RCPFES 2 4" RCP18" RCP LT LT CABLE BST 24" C&G CONC CONC 72" CHL 3-SBW BST BST BST 84" CHL 3-SBW 48" WW 1-SBW BST CONC 48" WW 1-SBW BILLBOARD LT LT WOODS WOODS CONC 48" WW 1-SBW STAUFFER GLOVE SAFETY CO. R/W MON EXISTING R/W EXISTING R/W EIP EIP EIP EIPEIP ; ; ; DI 15" RCPOUTLET COVER CONC. PIPE DI 24" RCP 30" RCP FES DI 24" RCPFES FES24" RCPTCONCCONC LOG CABIN HOMES, LTD NAD 83/ 2011 SHEET __ OF __ PERMIT DRAWING LEGEND GRAPHIC SCALE 0 252512.5 50 TS TS S 23 SEE SHEET 41 FOR -CD2- PROFILE SEE SHEET 39 FOR -CD1- PROFILESEE SHEET 16MATCHLINE -CD2- STA. 44+00.00,SEE SHEET 16MATCHLINE -CD1- STA. 39+00.00,SEE SHEET 24MATCHLINE -CD2- STA. 58+00.00, SEE SHEET 24MATCHLINE -CD1- STA. 53+00.00HYDRAULICSROADWAY DESIGN ENGINEER ENGINEER R/W SHEET NO. SHEET NO.PROJECT REFERENCE NO. INCOMPLETE PLANS DO NOT USE FOR R/W ACQUISITION REVISIONS PENTABLE:FILE:Barnhill_Contracting_Corp\Barnhill-Rocky_Mount_DB\6.0_CAD_BIM\6.2_WIP\Hydraulics\PERMITS_Environmental\Drawings\U5026-R5720_HYD_PRM_WET_PSH.dgnUSER:NWOMACKDATE:8/5/2020NCDOT_pdf_color_eng_100.pltPLOT DRIVER:8:46:04 AMTIME:NCDOT_permits_NOCON.tblDOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED HDR Engineering, Inc. of the Carolinas N.C.B.E.L.S. License Number: F-0116 555 Fayetteville St, Suite 900 Raleigh, N.C. 27601 U-5026 / R-5720 F C F F F F F C C C C C C C C C FFF F F F CC C4045 50455055505560505560-CD2- PC Sta. 53+03.08 -L2NB- PC Sta. 58+99.03 -L2SB- PC Sta. 58+99.38 -CD1- PC Sta. 48+58.41 -CD2- PT Sta. 57+76.47 NAD 83/ 2011 BARNHILL CONTRACTING COMPANY S S SURFACE WATER DENOTES IMPACTS IN TS TS IMPACTS IN SURFACE WATER DENOTES TEMPORARY SEE SHEET 23A 2GI 2GI 18" RCP-IV 48" RCP-IVTRENCHLESS INSTALLATION 48" WELDED STEEL 18" RCP-IV EST 50 SY GF EST 26 TONS EST 49 SY CLASS I RIP RAP EST 5 SY GF EST 1 TONS CLASS B RIP RAP FOR PROPOSAL UNLESS OTHERWISE NOTED ON THE PLANS. RIGHT-OF-WAY SHALL BE REMOVED AS DESCRIBED IN THE REQUEST ALL EXISTING DRAINAGE STRUCTURES AND PIPES WITHIN PROJECT HW RETAIN RETAIN FILL WITH FLOWABLE FILL DETAIL 23-2 SEE SHEET 2D-1 LATERAL BASE DITCH 2GI-A 2GI-A RETAIN DETAIL 23-3 SEE SHEET 2D-1 FS DETAIL 23-3 SEE SHEET 2D-1 FS DETAIL 23-3 SEE SHEET 2D-1 FS DETAIL 23-3 SEE SHEET 2D-1 FS RCP-IV48" DETAIL 23-1 SEE SHEET 2D-1 EST 50 SY GEOTEXTILE EST 35 TONS CLASS I RIP RAP RIP RAP AT EMBANKMENT DETAIL 23-4 SEE SHEET 2D-2 FS TOP EL=176.5 EST 10 SY GF EST 4 TONS EST 9 SY CLASS I RIP RAP 149 150 151 148 SC INTERMITTENT SC- PERENNIAL SC- WM/ WU WQ SITE 16 SITE 16 -CD2- STA. 46+20 RT D10= 2.5 ft V10= 1.9 fps Q10= 54 cfs D2= 2.2 ft V2= 1.8 fps Q2= 40 cfs SLOPE= 0.40% DA= 42.7 ac LATERAL BASE DITCH DATA RAP RIP BRK BUS LOADING DOCK S24" C&G 72" CHL 3-SBW 72" CHL 3-SBW BST BST CONC HOUSE PUMP FLAG POLE CONC WOODS WOODS 48" WW 1-SBW BKT ENTERPRISES, L.P. 3MR LIMITED PARTNERSHIP R/W MON R/W MON EXISTING R/W EXISTING R/W VARIES; DI 15" RCPFES 36" RCPFES FES DI24" RCPFES 2 4" RCP18" RCP LT LT CABLE BST 24" C&G CONC CONC 72" CHL 3-SBW BST BST BST 84" CHL 3-SBW 48" WW 1-SBW BST CONC 48" WW 1-SBW BILLBOARD LT LT WOODS WOODS CONC 48" WW 1-SBW STAUFFER GLOVE SAFETY CO. R/W MON EXISTING R/W EXISTING R/W EIP EIP EIP EIPEIP ; ; ; DI 15" RCPOUTLET COVER CONC. PIPE DI 24" RCP 30" RCP FES DI 24" RCPFES FES24" RCPTCONCCONC LOG CABIN HOMES, LTD NAD 83/ 2011 SHEET __ OF __ PERMIT DRAWING LEGEND GRAPHIC SCALE 0 252512.5 50 TS TS S 23 SEE SHEET 41 FOR -CD2- PROFILE SEE SHEET 39 FOR -CD1- PROFILESEE SHEET 16MATCHLINE -CD2- STA. 44+00.00,SEE SHEET 16MATCHLINE -CD1- STA. 39+00.00,SEE SHEET 24MATCHLINE -CD2- STA. 58+00.00, SEE SHEET 24MATCHLINE -CD1- STA. 53+00.00HYDRAULICSROADWAY DESIGN ENGINEER ENGINEER R/W SHEET NO. SHEET NO.PROJECT REFERENCE NO. INCOMPLETE PLANS DO NOT USE FOR R/W ACQUISITION REVISIONS PENTABLE:FILE:Barnhill_Contracting_Corp\Barnhill-Rocky_Mount_DB\6.0_CAD_BIM\6.2_WIP\Hydraulics\PERMITS_Environmental\Drawings\U5026-R5720_HYD_PRM_WET_PSH.dgnUSER:NWOMACKDATE:8/5/2020NCDOT_pdf_color_eng_100.pltPLOT DRIVER:8:46:50 AMTIME:NCDOT_permits_CON.tblDOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED HDR Engineering, Inc. of the Carolinas N.C.B.E.L.S. License Number: F-0116 555 Fayetteville St, Suite 900 Raleigh, N.C. 27601 U-5026 / R-5720 165 1 6 5 165165165165165 165 1 6 5165165 165 165 165 165 1 6 5 1 6 51651 6 5 170 170 170170170170170170 170 170170 170170170170170170170170170170 170 170 1701 7 0 175 175175 175175175175 175 175175175175175 175175 175175175 175175175175 1751 7 5 175175180 180 180 180180 180180180 180 180 180 180180180180180180180180 180 180 1 8 0 180180180180180 180 180 180 180 180 180 180180180180 180 180 180 1 8 0 1 8 0180 1 8 01 8 0185 1 8 5 185 185 185 185 1 8 5 F C F F F F F C C C C C C C C C FFF F F F CC C4045 50455055505560505560-CD2- PC Sta. 53+03.08 -L2NB- PC Sta. 58+99.03 -L2SB- PC Sta. 58+99.38 -CD1- PC Sta. 48+58.41 -CD2- PT Sta. 57+76.47 NAD 83/ 2011 BARNHILL CONTRACTING COMPANY S S SURFACE WATER DENOTES IMPACTS IN TS TS IMPACTS IN SURFACE WATER DENOTES TEMPORARY SEE SHEET 23A 2GI 2GI 18" RCP-IV 48" RCP-IVTRENCHLESS INSTALLATION 48" WELDED STEEL 18" RCP-IV EST 50 SY GF EST 26 TONS EST 49 SY CLASS I RIP RAP EST 5 SY GF EST 1 TONS CLASS B RIP RAP FOR PROPOSAL UNLESS OTHERWISE NOTED ON THE PLANS. RIGHT-OF-WAY SHALL BE REMOVED AS DESCRIBED IN THE REQUEST ALL EXISTING DRAINAGE STRUCTURES AND PIPES WITHIN PROJECT HW RETAIN RETAIN FILL WITH FLOWABLE FILL DETAIL 23-2 SEE SHEET 2D-1 LATERAL BASE DITCH 2GI-A 2GI-A RETAIN DETAIL 23-3 SEE SHEET 2D-1 FS DETAIL 23-3 SEE SHEET 2D-1 FS DETAIL 23-3 SEE SHEET 2D-1 FS DETAIL 23-3 SEE SHEET 2D-1 FS RCP-IV48" DETAIL 23-1 SEE SHEET 2D-1 EST 50 SY GEOTEXTILE EST 35 TONS CLASS I RIP RAP RIP RAP AT EMBANKMENT DETAIL 23-4 SEE SHEET 2D-2 FS TOP EL=176.5 EST 10 SY GF EST 4 TONS EST 9 SY CLASS I RIP RAP 149 150 151 148 SC INTERMITTENT SC- PERENNIAL SC- WM/ WU WQ SITE 16 SITE 16 -CD2- STA. 46+20 RT D10= 2.5 ft V10= 1.9 fps Q10= 54 cfs D2= 2.2 ft V2= 1.8 fps Q2= 40 cfs SLOPE= 0.40% DA= 42.7 ac LATERAL BASE DITCH DATA RAP RIP BRK BUS LOADING DOCK S 72" CHL 3-SBW 72" CHL 3-SBW BST CONC HOUSE PUMP FLAG POLE CONC WOODS WOODS EXISTING R/W EXISTING R/W VARIES; DI 15" RCPFES 36" RCPFES FES LT 24" C&G CONC BST BST ; DI 24" RCP 30" RCP FES DI 24" RCPFES 24" RCPTCONCCONC SHEET __ OF __ PERMIT DRAWING LEGEND NAD 83/ 2011 TS GRAPHIC SCALE 0 252512.5 50 TS HYDRAULICSROADWAY DESIGN ENGINEER ENGINEER R/W SHEET NO. SHEET NO.PROJECT REFERENCE NO. INCOMPLETE PLANS DO NOT USE FOR R/W ACQUISITION REVISIONS PENTABLE:FILE:Barnhill_Contracting_Corp\Barnhill-Rocky_Mount_DB\6.0_CAD_BIM\6.2_WIP\Hydraulics\PERMITS_Environmental\Drawings\U5026-R5720_HYD_PRM_WET_PSH.dgnUSER:NWOMACKDATE:8/5/2020NCDOT_pdf_color_eng_100.pltPLOT DRIVER:8:44:24 AMTIME:NCDOT_permits_NOCON.tbl23AU-5026 /R-5720 DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED HDR Engineering, Inc. of the Carolinas N.C.B.E.L.S. License Number: F-0116 555 Fayetteville St, Suite 900 Raleigh, N.C. 27601 C F F F C C C F F C4045SSSURFACE WATER DENOTES IMPACTS IN TS TS IMPACTS IN SURFACE WATER DENOTES TEMPORARY 2GI 48" RCP-IVTRENCHLESS INSTALLATION 48" WELDED STEEL 18" RCP-IV HW RETAIN FILL WITH FLOWABLE FILL 2GI-A 2GI-A DETAIL 23-3 SEE SHEET 2D-1 FS DETAIL 23-3 SEE SHEET 2D-1 FS DETAIL 23-3 SEE SHEET 2D-1 FS RCP-IV48" DETAIL 23-1 SEE SHEET 2D-1 EST 50 SY GEOTEXTILE EST 35 TONS CLASS I RIP RAP RIP RAP AT EMBANKMENT DETAIL 23-4 SEE SHEET 2D-2 FS TOP EL=176.5 EST 10 SY GF EST 4 TONS EST 9 SY CLASS I RIP RAP INTERMITTENT SC- PERENNIAL SC- SITE 16 Hand Permanent Permanent Existing Existing Permanent Temp. Excavation Mechanized Clearing SW SW Temp. Channel Channel Natural Site Station Structure Fill In Fill In in Clearing in impacts impacts SW Impacts Impacts Stream No. (From/To) Size / Type Wetlands Wetlands Wetlands in Wetlands Wetlands (Pond) (Stream) impacts Permanent Temp. Design (ac) (ac) (ac) (ac) (ac) (ac) (ac) (ac) (ft) (ft) (ft) 1 14+06 - 14+44 -L- LT BANK AND SCOUR HOLE STABILIZATION < 0.01 < 0.01 47 10 2 36+90 - 37+63 -L- LT ROADWAY FILL < 0.01 133 2 36+90 - 37+63 -L- LT BANK STABILIZATION < 0.01 < 0.01 28 29 3 40+13 - 41+21 -L- 10' X 7' RCBC 0.02 140 3 40+13 - 41+21 -L- LT CHANNEL RELOCATION 0.01 < 0.01 90 9 3 41+14 - 41+50 -L- RT CHANNEL RELOCATION < 0.01 < 0.01 18 21 4 40+60 - 41+83 -L- LT ROADWAY FILL 0.13 < 0.01 0.05 5 155+5 -L- LT 48" RCP-IV < 0.01 45 5 155+5 -L- LT OUTLET CHANNEL PROTECTION < 0.01 < 0.01 16 6 6 183+5 - 189+91, 192+80 - 197+07 -L- LT ROADWAY FILL/ CHANNEL RELOCATION 0.11 < 0.01 1192 49 6 197+00 - 198+00 -L- LT BANK STABILIZATION < 0.01 < 0.01 72 10 7 197+00 - 198+00 -L- LT ROADWAY FILL < 0.01 86 8 199+15 - 200+13, 201+20 - 201+71 ROADWAY CLEARING 0.03 9 14+34 - 16+96, 17+07 - 18+37 -L2NB- RT ROADWAY FILL 0.24 0.07 0.18 10 12+49 - 12+81 -L2NB- ROADWAY CLEARING < 0.01 11 11+82 - 12+41 -L2SB- LT ROADWAY CLEARING 0.05 12 14+88 - 16+34, 21+41 - 22+56 -L2SB- LT ROADWAY FILL 0.06 0.05 0.06 13 20+00 -CD2- RT DITCH TIE-IN < 0.01 44 14 18+61 -CD2- RT TO 29+95 -CD2- CL ROADWAY CUT/FILL, BASE DITCH 0.12 1.23 0.03 0.10 TOTALS* THIS SHEET:0.55 0 1.23 0.23 0.39 0 0.18 0.01 1911.00 134.00 0 TOTALS* ENTIRE U-5026:0.55 0.00 2.24 0.42 0.45 0.00 0.20 0.02 2120.00 209.00 0.00 *Rounded totals are sum of actual impacts. NOTES: Revised 2016 09 09 SHEET OF WETLAND AND SURACE WATER IMPACTS SUMMARY WETLAND IMPACTS SURFACE WATER IMPACTS NASH COUNTY TIP U-5026 STATE PROJ. # 44033.3.3 NC DEPARTMENT OF TRANSPORTATION DIVISION OF HIGHWAYS AUGUST 2020 Hand Permanent Permanent Existing Existing Permanent Temp. Excavation Mechanized Clearing SW SW Temp. Channel Channel Natural Site Station Structure Fill In Fill In in Clearing in impacts impacts SW Impacts Impacts Stream No. (From/To)Size / Type Wetlands Wetlands Wetlands in Wetlands Wetlands (Pond) (Stream) impacts Permanent Temp. Design (ac) (ac) (ac) (ac) (ac) (ac) (ac) (ac) (ft) (ft) (ft) 15 11+00 -LRPC- LT TO 17+46 -LRPC- CL ROADWAY EXCAVATION 1.01 0.18 0.06 16 42+72 - 43+20 -CD1- LT 48" RCP-IV < 0.01 < 0.01 < 0.01 52 39 16 51+34 - 51+97 -L2NB- RT ROADWAY FILL < 0.01 82 16 51+34 - 51+97 -L2NB- RT 15" RCP / BANK STABILIZATION < 0.01 < 0.01 36 23 17 75+82 -L- RT BANK STABILIZATION < 0.01 < 0.01 39 13 TOTALS* THIS SHEET:0 0 1.01 0.19 0.06 0 0.02 0.01 209.00 75.00 0 TOTALS* ENTIRE U-5026:0.55 0.00 2.24 0.42 0.45 0.00 0.20 0.02 2120.00 209.00 0.00 *Rounded totals are sum of actual impacts. NOTES: Revised 2016 09 09 SHEET OF WETLAND AND SURACE WATER IMPACTS SUMMARY WETLAND IMPACTS SURFACE WATER IMPACTS NASH COUNTY TIP U-5026 STATE PROJ. # 44033.3.3 NC DEPARTMENT OF TRANSPORTATION DIVISION OF HIGHWAYS AUGUST 2020