Loading...
HomeMy WebLinkAbout20181245 Ver 2_SuppEZ 8_17_20_20200817 SUPPLEMENT-EZ COVER PAGE FORIVIS LOADED Pl7OJ]ECT INFORMATION Project.Name Ferguson Street Development 2 Project Area ac 22.31 Acres 3 Coastal Wetland Area ac _ 0 -- 4 Surface Water Area ac 3133 5 is this ra ect High or Low Densi 7 High 6 floes this project use an off-site SCM? No COMPLIANCE WI:6jjWA2 i.[4 7 1 Width of etated setbacks provided feet N/A 8 lWiil the v etated setback remainvegetated? NIA 9 Ilf BUA is prop2sed in the setback,does it meet NCAC 02H_10 4)Jc-d? N/A 10 1 Is strreambank stabilization proposed on this project? No NUMBER AND TYPE OF S.CMs: 11 linfiftration System 12 Biaretention Cell 1 13 Wet Pond t4 Stomtwater Wetland 15 Permeable Pavement 16 Sand Filter 17 Rainwater Harvesting RWH 18 Green Roof 19 Level Spreader-Filter Stn LS-FS 20 Disconnected Impervious Surface DIS 21 Treatment Swale 22 Dry Pond 23 StormFilter 24 Silva Cell -- 25 Ba Iter 26 Flterra FQRMSLOADED DESIGNER CERTIFICATION 27 Name and Title WiNiam A.Stillwell,Pro ect E lneer 28 D anization: Sttlh%*Jl Engineer€.Inc. 28 Street address: 42 Marsh Lily brine 30 City.State Zip- Zukun,NC 28779 31 Phone numbe s: 828.586,6066 32 Email: w.stilts+e€l@stiilwellengineering.net Certification Statement I certify,under penalty of law that this Supplement EZ form and all supporting information were Prepared under my direction or supervision;that the information provided in the Form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans, specifications,operation and maintenance agreements and other supporting information are consistent with the information provided here. t7esr4ner lirk CA n 'zp E551p = Q SEAL Signature of Designer 026084 70 t111W0 Date Sea DRAINAGE AREAS !, Is this a high densitproject? v. . _ Yes.. 2 if so number of drains a areas/SCMs 2 _ 3 Does this project have low densy areas? No _ 4 If so,number of low clensy drainage areas 0 Is alllpart of this project subject to previous rule 5 versions? No FARMS LOAI)E❑ DRAINAGE AREA INFORMATION Entire Site 1 2 4 1 TvDe of SC None Bioretention Cell 5 Total drainage areas ft 124582 sf 22216 sf 102366 sf fi lOnsite drainage area ft 103238 sf 22216 sf 81022 sf 7 Offsite drainage area(sq 41 sf s€ sf 8 Totai BUA in ro ct(sq ft sf sf sf New BUA on subdivided lots(subject to permitting) g ft sf sf sf New BUA not on subdivided lots[subject to 10 ermittin� s sf sf sf 11 Offsite BUA ftl sf sf sf 12 Breakdown of new BUA not on subdivided lots: 7-Parkin (sqM -Sidewalk q ft -Root WE ft -Road wa s It -Futures ft Other,please specify in the comment box below ft New infiltrating permeable pavement on 13 subdivided lots ft sf sf sf New infiltrating permeable pavement not on 14 subdivided lots ft sf sf sf Existing BUA that will remain{not subject to 15permitting) s ft sf sf sf 16 Fxistinq BUA that is already rrnitted s fl sf sf sf 17 Existing BUA that will be removed(sq ft 21344 sf sf 21344 sf 18 Percent BUA 22% 71% 18 Des n storm inches 1.0 in 1.0 in 1-0 in 20 Desi n volume of 5CM cu tt of Of 6743 cf 21 lGaiculation method for design volume Simple Method ADDITIONAL INFORMATION. Please use this space to provide any additional information about the 22 drains a area s]: Drainage area has been split into two proposed parcels,one for a commercial facility and one for a residential development.The residential development parcel has been designed for low density_ BIORETENTION CELL 1 I Drainage area.number _ 2 2 !Minimum required treatment volume cu ft) ! 6683 cf ENERALMM FROM 02H.1050 _ 3 is the SCM sized to treat the SW from all surfaces at build-out? Yes 4 Is the SCM located away from contaminated soils? Yes 5 What are the side slopes of the SCM(H.V)? 3=1 6 1 Does the SCM have retaining walls,gabion walls or other engineered side slopes? No 7 Are the inlets,outlets,and receiving stream protected from erosion (10-year storm)? _ Yes 8 Is there an overflow or bypass for inflow volume in excess of the design volume? Yes 9 What is the method for dewatering the SCM for maintenance? Pump(preferred) 10 If applicable,will the SCM be cleaned out after construction? Yes 11 Does the maintenance access comply with General MDC(8)? Yes 12 Does the drainage easement comply with General MDC(9)? Yes 13 If the SCM is on a single family lot,does(will?)the plat comply with General MDC(10)? NIA 14 is there an O&M Agreement that complies with General MDC(11)? No 15 is there an O&M Plan that complies with General MDC(12)? Yes 1e Does the SCM follow the device specific MDC? Yes t7 Was the SCM designed by an NC licensed professional? Yes BIORETENTION CELL.MDC FROM 02H.1052 18 SHWT elevation(fmsl] - ,W Unknown 19 1 Bottom of the bioretention cell(fmst) 2W.00 20 Ponding depth of the design storm(inches) 12 in 21 Surface area of the bioretention cell(square feet) LL 7459 sf 22 Desi n volume of SCM cu fl ee83 cf 23 is the bioretention cell used for peak attenuation? Yes 24 Depth of peak attenuation over planting surface(in) 24 in 25 Height of peak attenuation outlet above the planting surface(in) 18 in 26 Infiltration rate of the in situ soil(inch/hour) 2 inlhr 27 Diameter of the underdrain pipes(if applicable) 8 in 28 Does the design include Internal Water Storage(IWS)? Yes 29 if so,elevation of the top of the IWS(frnsl) 2143,5 30 Elevation of the planting surface(fmsl) 2145 31 What type of vegetation will be planted? (grass,trees/shrubs, other)? Grass 32 Media depth(inches) 30 in 33 J.Percentege of medium to coarse washed sand by volume 75% 34 Percentage of fines(silt and day)by volume 8% 35 Percentage of organic matter by volume 5% 3e Type of organic material Pine Bark Fines 37 Phosphorus Index(P-Index)of media(unitless) 49 MAX 38 Will compaction be avoided during construction? Yes 39 Will cell be maintained to a one inchlhour standard? Yes 40 Depth of mulch,if applicable(inches) NIA 41 Type of mulch,if applicable NIA 42 r How many dean out pipes are being installed? 2 43 Type of pretreatment that will be used: FOREBAY ADDITIONAL INFORMATION 44 jPeease use this space to provide any additional information about the bioretention cell(s): A drainage maintenanance and access easement has been tentatively established but not yet recorded until review of stormwater plan is completed -An operation and maintenance manual has been established but not yet retarded until review of the plan is completed.SHWT is in excess of 2'below proposed cell media,which is being placed entirely in a frll area Bioretention 1 3.28 PM 8/14/2020