HomeMy WebLinkAboutSW5200701_Supplement EZ Form 8-28-20_20200828SUPPLEMENT-EZ COVER PAGE
FORMS LOADED
PROJECT INFORMATION
1 Project Name
2 Project Area ac
3 Coastal Wetland Area (ac)
Bojangles at Spring Hope
7.87
0
5 Its this project High or Low Density? High
6 1 Does this project use an off -site SCM? No
)MPLIANCE WITH 02H .1003(4)
8 Will the vegetated setback remain vegetated? Yes
9 Is BUA other that as listed in .1003(4)(c-d) out of the setback? N/A
10 Is streambank stabilization proposed on this project? No
NUMBER AND TYPE OF SCMs:
11
Infiltration System
0
12
Bioretention Cell
0
13
Wet Pond
1
14
Stormwater Wetland
0
15
Permeable Pavement
0
16
Sand Filter
0
17
Rainwater Harvesting RWH
0
18
Green Roof
0
19
Level Spreader -Filter Strip LS-FS
0
20
Disconnected Impervious Surface (DIS)
0
21
Treatment Swale
0
22
Dry Pond
0
23
StormFilter
0
24
Silva Cell
0
25
Ba filter
0
26
Filterra
0
FORMS LOADED
I (CATION - -
Name and Title: J. Michael Stocks, PE
27
28
Organization:
Stocks Engineering
29
Street address:
801 E Washington St.
30
City, State, Zip:
Nashville, NC 27856
31
Phone numbers :
252-459-8196
32
Email:
mstocks@stocksengineering.com
Certification Statement:
I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or
supervision; that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and
that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent
with the information provided here.
,,�IIIIIIIIr11+�,
��
•;*IESS/o • •
a SEAL
• 19843
01'h I YAEL cJ� �••`�
Se�1111111�`
�(.•Q P%la,4'
Sig ature of D signer
Date
e17- 7/0-0 Zo
DRAINAGE AREAS
1
Is this a high density project?
Yes
2
If so, number of drainage areas/SCMs
1
3
Is all/part of this project subject to previous rule
versions?
No
FORMS LOADED
DRAINAGE AREA INFORMATION
Entire Site
4
Type of SCM
N/A
5
Total BUA in project s ft
149955 sf
6
F7
New BUA on subdivided lots (subject to permitting)
s ft
sf
New BUA outside of subdivided lots (subject to
permitting)s
144920 sf
8
Offsite - total area (sq ft
sf
9
Offsite BUA (sq ft
sf
10
Breakdown of new BUA outside subdivided lots:
Parking (sq ft
51962 sf
Sidewalk (sq ft
2473 sf
- Roof (sq ft
3500 sf
- Roadway s ft
21645 sf
- Future (sq ft
65340 sf
- Other, please specify in the comment box
below (sq ft
sf
11
New infiltrating permeable pavement on
subdivided lots (sq ft
sf
12
New infiltrating permeable pavement outside of
subdivided lots (sq ft
sf
13permitting)
Exisitng BUA that will remain (not subject to
s ft
5035 sf
14
Existing BUA that is already permitted (sq ft
sf
15
Existing BUA that will be removed (sq ft
sf
16
Percent BUA
44%
17
Design storm inches
18
Design volume of SCM cu ft
19
Calculation method for design volume
ADDITIONAL INFORMATION
20
Please use this space to provide any additional information about the
drainage area(s):
i
Wet Pond
149955 sf
sf
144920 sf
sf
sf
51962 sf
2473 sf
3500 sf
21645 sf
65340 sf
sf
sf
44%
1 in
12602 cf
WET POND
1
Drainage area number
1
21 Design volume of SCM (cu ft)
GENERAL MDC FROM 02H .1050
31 Is the SCM sized to treat the SW from all surfaces at build -out?
12602 c(:J
Fes
4
Is the SCM located away from contaminated soils?
Yes
5
What are the side slopes of the SCM (H:V)?
3:1
6
Does the SCM have retaining walls, gabion walls or other engineered
side slopes?
No
7
Are the inlets, outlets, and receiving stream protected from erosion
(10-year storm)?
Yes
81
Is there an overflow or bypass for inflow volume in excess of the
design volume?
Yes
9
What is the method for dewatering the SCM for maintenance?
Pump (preferred)
10
If applicable, will the SCM be cleaned out after construction?
Yes
11
Does the maintenance access comply with General MDC (8)?
Yes
12
Does the drainage easement comply with General MDC (9)?
Yes
13
If the SCM is on a single family lot, does (will?) the plat comply with
General MDC (10)?
Yes
14
Is there an O&M Agreement that complies with General MDC (11)?
Yes
15
Is there an O&M Plan that complies with General MDC (12)?
Yes
16
Does the SCM follow the device specific MDC?
Yes
17 Was the SCM designed by an NC licensed professional?
WET POND MDC FROM 02H .1053
181 Method used
Yes
SA/DA
19
Has a stage/storage table been provided in the calculations?
Yes
20
Elevation of the excavated main pool depth (bottom of sediment
removal) (fmsl)
240.00
21
Elevation of the main pool bottom -(top of sediment removal) (fmsi)
241.00
22
Elevation of the bottom of the vegetated shelf (fmsl)
246.00
231
Elevation of the permanent pool (fmsl)
246.50
24
Elevation of the top of the vegetated shelf (fmsi)
247.00
25
Elevation of the temporary pool (fmsl)
248.03
26
Surface area of the main permanent pool (square feet)
5529:1
27
Volume of the main permanent pool (cubic feet)
15356 cf
28
Average depth of the main pool (feet)
3.40 ft
29
Average depth equation used
Equation 2
301
If using equation 3, main pool perimeter (feet)
31
If using equation 3, width of submerged veg. shelf (feet)
32
Volume of the forebay (cubic feet)
3183 of
33
Is this 15-20% of the volume in the main pool?
Yes
34
Clean -out depth for forebay (inches)
12 in
35
Design volume of SCM (cu ft)
12602 cf
36
Is the outlet an orifice or a weir?
Orifice
371
If orifice, orifice diameter (inches)
1 in
38
If weir, weir height (inches)
39
If weir, weir length (inches)
40
Drawdown time for the temporary pool (days)
4
41
Are the inlet(s) and outlet located in a manner that avoids short-
circuiting?
Yes
42
Are berms or baffles provided to improve the flow path?
No
431
Depth of forebay at entrance (inches)
54 in
44
Depth of forebay at exit (inches)
42 in
45
Does water flow out of the forebay in a non -erosive manner?
Yes
46
Width of the vegetated shelf (feet)
6 ft
47
Slope of vegetated shelf (H:V)
6:1
48
Does the orifice drawdown from below the top surface of the
permanent pool?
Yes
491
Does the pond minimize impacts to the receiving channel from the 1 -
yr, 24-hr storm?
Yes
50
Are fountains proposed? (If Y, please provide documentation that
MDC(9) is met.)
No
51
Is a trash rack or other device provided to protect the outlet system?
Yes
52
Are the dam and embankment planted in non -clumping turf grass?
Yes
53
Species of turf that will be used on the dam and embankment
Centipede
541
Has a planting plan been provided for the vegetated shelf?
Yes
ADDITIONAL INFORMATION
55
Please use this space to provide any additional information about the
wet pond(s):
Wet Pond 3 11:35 AM 8/24/2020