HomeMy WebLinkAboutNC0020354_Compliance Evaluation Inspection_20200825ROY COOPER
Governor
MICHAEL S. REGAN
Secretary
S. DANIEL SMITH
Director
Chris Kennedy, Town Manager
PO Box 759
Town of Pittsboro
Pittsboro, NC 27312-0759
NORTH CAROLINA
Environmental Quality
August 25, 2020
Subject: Compliance Evaluation Inspection
Pittsboro WWTP
NPDES Permit NCO020354
Chatham County
Dear Mr. Kennedy:
On July 22, 2020, Cheng Zhang of the Raleigh Regional Office (RRO) conducted a Compliance
Evaluation Inspection at the subject facility. The assistance provided by Mr. Jamie McLaurin, Operator
in Responsible Charge (ORC), was appreciated. The inspection report is attached. Findings during the
inspection were as follows:
The facility is currently permitted to discharge up to 0.75 MGD into Robeson Creek, a Class WS-
IV NSW waters in the Cape Fear River Basin. Current permit expired on April 30, 2016. The
Town submitted permit renewal application on January 26, 2016, which was received by the
Division on February 5, 2016.
2. The plant is classified as a WW-3 wastewater facility. Mr. Jamie McLaurin is designated as the
ORC; Mr. Freddy Peele is designated as the backup ORC. Daily operation log books are detailed
and are kept onsite going back at least three years.
3. Field lab parameter (Certificate No. 5670) calibration and analysis records were reviewed during
the inspection. The inspector reminded Mr. McLaurin of new rules that require field labs to
have Standard Operating Procedures (SOPs) and develop and implement a documented
training program. March 2020 DMR data was compared to bench sheets and lab reports; no data
transcription errors were noted. Lab results, chain -of -custody forms, and DMRs, were complete
and organized.
4. The permit lists the following units; all were observed during the inspection:
• Influent pump station with two pumps (with a diesel pump serving as bypass pump), both pumps
were operable;
norDE Q�� North Carolina Department of Environmental Quality I Division of Water Resources
r rnani wa Raleigh Regional Office 13800 Barrett Drive I Raleigh, North Carolina 27609
oep'm 't ie n��m.nni"i;� 919.791.4200
• One mechanical bar screen in operation, the manual bar screen is only used during periods with
high flow;
• Two equalization basin was used to achieve steady flow (0.35 MGD) through the plant under
normal conditions;
• Two secondary clarifiers, sludge is returned to aeration basins via ail lifting;
• Two aeration basins with fine bubble diffusers;
• Three up -flow tertiary filters;
• Two banks of UV disinfection units (one in use);
• One waste activated sludge pump station with two pumps;
• Two aerobic digesters hold thickened, wasted sludge. At the time of inspection, Synagro was
hauling sludge, one digester was empty, the other was being emptied;
• One rotary drum thickener is used to dewater wasted sludge before it is stored in the two aerobic
digesters (not in use at the time of inspection);
• The on -site generator is tested every week; fuel level is checked and recorded every day.
5. The right of way to the outfall was properly maintained. The effluent appeared clear and free of
solids. There were no visible detrimental impacts to the receiving stream.
This facility was found to be compliant with NPDES permit conditions. The plant is well maintained
and documentation was found to be detailed, organized, and complete. If you have any questions
regarding the attached report, please contact Cheng Zhang at 919-791-4200 (or email:
cheng. zhang@ncdenr. gov).
Sincerely,
DocuSigned by:
UaL�,t,SSa f.
B2916E6A832144F...
Vanessa E. Manuel, Assistant Regional Supervisor
Water Quality Regional Operations Section
Raleigh Regional Office
Division of Water Resources
Attachments: EPA Water Compliance Inspection Report
Cc: Central Files w/attachment (Laserfiche)
Raleigh Regional Office w/attachment
Jamie McLaurin, ORC (electronic copy only)
United States Environmental Protection Agency
Form Approved.
EPA Washington, D.C. 20460
OMB No. 2040-0057
Water Compliance Inspection Report
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 IN 1 2 u 3 I NCO020354 I11 121 20/07/22 I17 18I � I 19 I s I 201 I
211IIIII 111111III II III III1 I I IIIII IIIIIIIII II r6
Inspection
Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved -------------------
67
I 72 I ni I 71 I 74 79 I I I I I I I80
701� I 711 L
LJ L -1 I I
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
Entry Time/Date
Permit Effective Date
POTW name and NPDES Dermit Number)
09:30AM 20/07/22
14/09/01
Pittsboro WWTP
Small St Extension
Exit Time/Date
Permit Expiration Date
Pittsboro NC 27312
01:OOPM 20/07/22
16/04/30
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
Other Facility Data
Jamie Lee McLaurin/ORC/919-542-2444/
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Holly Coleman,40 E Chatham St Pittsboro NC 27312//919-542-8215/9195458449
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit 0 Flow Measurement Operations & Maintenar Records/Reports
Self -Monitoring Progran 0 Sludge Handling Dispo: Facility Site Review Effluent/Receiving Wate
Laboratory
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date
Cheng Zhang Docusignedby: DWR/RRO WQ/919-791-4200/
E� Vaf-., - 8/25/2020
71508EI EC41 F...
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
DocuSigned by:
DWR/RRO WQ/919-791-4232 8/25/2020 a,Int,SSa �tia�,u�,�
U �.
EPABPorrn d6114(Rev 9-94) Previous editions are obsolete.
Page#
NPDES yr/mo/day Inspection Type
NCO020354 I11 12I 20/07/22 117 18 i c i
(Cont.)
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
1. The facility is currently permitted to discharge up to 0.75 MGD into Robeson Creek, a Class WS-IV
NSW waters in the Cape Fear River Basin. Current permit expired on April 30, 2016. The Town
submitted permit renewal application on January 26, 2016, which was received by the Division on
February 5, 2016.
2. The plant is classified as a WW-3 wastewater facility. Mr. Jamie McLaurin is designated as the
ORC; Mr. Freddy Peele is designated as the backup ORC. Daily operation log books are detailed and
are kept onsite going back at least three years.
3. Field lab parameter (Certificate No. 5670) calibration and analysis records were reviewed during
the inspection. The inspector reminded Mr. McLaurin of new rules that require field labs to have
Standard Operating Procedures (SOPs) and develop and implement a documented training program.
March 2020 DMR data was compared to bench sheets and lab reports; no data transcription errors
were noted. Lab results, chain -of -custody forms, and DMRs were complete and organized.
4. The permit lists the following units; all were observed during the inspection:
• Influent pump station with two pumps (with a diesel pump serving as bypass pump), both pumps
were operable;
• One mechanical bar screen in operation, the manual bar screen is only used during periods with
high flow;
• Two equalization basin was used to achieve steady flow (0.35 MGD) through the plant under
normal conditions;
• Two secondary clarifiers, sludge is returned to aeration basins via ail lifting;
• Two aeration basins with fine bubble diffusers;
• Three up flow tertiary filters;
• Two banks of UV disinfection units (one in use);
• One waste activated sludge pump station with two pumps;
• Two aerobic digesters hold thickened wasted sludge. At the time of inspection, Synagro was
hauling sludge, one digester was empty, the other was being emptied;
• One rotary drum thickener is used to dewater wasted sludge before it is stored in the two aerobic
digesters (not in use at the time of inspection);
• The on -site generator is tested every week, fuel level is checked and recorded every day.
5. The right of way to the outfall was properly maintained. The effluent appeared clear and free of
solids. There were no visible detrimental impacts to the receiving stream.
This facility was found to be compliant with NPDES permit conditions as a result of this inspection.
Page#
Permit: NCO020354 Owner -Facility: Pittsboro WWTP
Inspection Date: 07/22/2020 Inspection Type: Compliance Evaluation
Operations & Maintenance
Yes No
NA
NE
Is the plant generally clean with acceptable housekeeping?
0 ❑
❑
❑
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable
❑
❑
❑
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment: the facility analyzes the following process control parameters: MLSS,
MCRT, SVI,
FT,
F/M,
alkalinity, settleable solids, pH, DO, sludge judge, Secchi disk depths,
ammonia, and total
phosphorous (influent and effluent)
Permit
Yes
No
NA
NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new
0
❑
❑
❑
application?
Is the facility as described in the permit?
❑
0
❑
❑
# Are there any special conditions for the permit?
❑
0
❑
❑
Is access to the plant site restricted to the general public?
0
❑
❑
❑
Is the inspector granted access to all areas for inspection?
E
❑
❑
❑
Comment: Treatment units not listed: influent pump station and eclaulization basins
Bar Screens
Yes
No
NA
NE
Type of bar screen
a.Manual
b.Mechanical
Are the bars adequately screening debris?
0
❑
❑
❑
Is the screen free of excessive debris?
0
❑
❑
❑
Is disposal of screening in compliance?
0
❑
❑
❑
Is the unit in good condition?
0
❑
❑
❑
Comment: Manual bar screen is only used in high flow situations.
Aeration Basins
Yes No
NA
NE
Mode of operation
Ext. Air
Type of aeration system
Diffused
Is the basin free of dead spots?
0 ❑
❑
❑
Are surface aerators and mixers operational?
0 ❑
❑
❑
Are the diffusers operational?
0 ❑
❑
❑
Is the foam the proper color for the treatment process?
0 ❑
❑
❑
Does the foam cover less than 25% of the basin's surface?
0 ❑
❑
❑
Is the DO level acceptable?
E ❑
❑
❑
Page# 3
Permit: NCO020354
Inspection Date: 07/22/2020
Aeration Basins
Is the DO level acceptable?(1.0 to 3.0 mg/1)
Owner -Facility: Pittsboro WWTP
Inspection Type: Compliance Evaluation
Yes No NA NE
■ ❑ ❑ ❑
Comment: DO levels in both basins vary from 1 to 3 mq/L depending on how many blowers (four
blowers) are turned on
Secondary Clarifier
Is the clarifier free of black and odorous wastewater?
Is the site free of excessive buildup of solids in center well of circular clarifier?
Are weirs level?
Is the site free of weir blockage?
Is the site free of evidence of short-circuiting?
Is scum removal adequate?
Is the site free of excessive floating sludge?
Is the drive unit operational?
Is the return rate acceptable (low turbulence)?
Is the overflow clear of excessive solids/pin floc?
Is the sludge blanket level acceptable? (Approximately'/ of the sidewall depth)
Yes
No
NA NE
■
❑
❑
❑
•
❑
❑
❑
•
❑
❑
❑
•
❑
❑
❑
•
❑
❑
❑
•
❑
❑
❑
•
❑
❑
❑
•
❑
❑
❑
•
❑
❑
❑
•
❑
❑
❑
•
❑
❑
❑
Comment: Sludqe blankets at time of inspection, 6 feet (clarifier #1), 3 feet (clarifier #2
Filtration (High Rate Tertiary)
Yes
No
NA NE
Type of operation:
Up flow
Is the filter media present?
❑
❑
❑
Is the filter surface free of clogging?
❑
❑
❑
Is the filter free of growth?
❑
❑
❑
Is the air scour operational?
❑
❑
❑
Is the scouring acceptable?
❑
❑
❑
Is the clear well free of excessive solids and filter media?
❑
❑
❑
Comment: Sand media are backwashed constantly
Nutrient Removal
Yes
No
NA NE
# Is total nitrogen removal required?
❑
0
❑ ❑
# Is total phosphorous removal required?
0
❑
❑ ❑
Type
Chemical
# Is chemical feed required to sustain process?
0
❑
❑ ❑
Page# 4
Permit: NCO020354
Inspection Date: 07/22/2020
Nutrient Removal
Is nutrient removal process operating properly?
Comment: Sodium aluminate is fed into the front
Disinfection - UV
Are extra UV bulbs available on site?
Are UV bulbs clean?
Is UV intensity adequate?
Is transmittance at or above designed level?
Is there a backup system on site?
Is effluent clear and free of solids?
Owner -Facility: Pittsboro WWTP
Inspection Type: Compliance Evaluation
of each basin
Yes No NA NE
■ ❑ ❑ ❑
Yes No NA NE
❑ ■ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
❑ ■ ❑ ❑
■ ❑ ❑ ❑
Comment: UV system with two banks of bulbs, one bank was on line at time of inspection,
both banks
will be turned on during high flow periods. A contractor is responsible for UV system
maintenance. Bulbs are cleaned automatically.
Laboratory
Yes
No
NA
NE
Are field parameters performed by certified personnel or laboratory?
0
❑
❑
❑
Are all other parameters(excluding field parameters) performed by a certified lab?
0
❑
❑
❑
# Is the facility using a contract lab?
0
❑
❑
❑
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
❑
❑
0
❑
Celsius)?
Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees?
❑
❑
0
❑
Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees?
❑
❑
0
❑
Comment: The facility only analyzes field parameters, all other parameters are analyzed by Enco
Pumps-RAS-WAS
Yes
No
NA
NE
Are pumps in place?
M
❑
❑
❑
Are pumps operational?
0
❑
❑
❑
Are there adequate spare parts and supplies on site?
0
❑
❑
❑
Comment: Sludge is returned via air lifting (eletric pumps available as backup). WAS pump station with
two pumps, one for each clarifier
Standby Power
Yes
No
NA
NE
Is automatically activated standby power available?
0
❑
❑
❑
Is the generator tested by interrupting primary power source?
❑
0
❑
❑
Is the generator tested under load?
❑
0
❑
❑
Page# 5
Permit: NCO020354 Owner -Facility: Pittsboro WWTP
Inspection Date: 07/22/2020 Inspection Type: Compliance Evaluation
Standby Power
Yes
No
NA
NE
Was generator tested & operational during the inspection?
❑
0
❑
❑
Do the generator(s) have adequate capacity to operate the entire wastewater site?
0
❑
❑
❑
Is there an emergency agreement with a fuel vendor for extended run on back-up power?
0
❑
❑
❑
Is the generator fuel level monitored?
M
❑
❑
❑
Comment: The generator is tested every week (not under loa
Influent Sampling
Yes
No
NA
NE
# Is composite sampling flow proportional?
❑
0
❑
❑
Is sample collected above side streams?
0
❑
❑
❑
Is proper volume collected?
0
❑
❑
❑
Is the tubing clean?
0
❑
❑
❑
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
0
❑
❑
❑
Celsius)?
Is sampling performed according to the permit?
0
❑
❑
❑
Comment: Time paced composite samples collected at influent (250 ml/20 minutes)
Effluent Sampling
Yes
No
NA
NE
Is composite sampling flow proportional?
❑
0
❑
❑
Is sample collected below all treatment units?
0
❑
❑
❑
Is proper volume collected?
0
❑
❑
❑
Is the tubing clean?
0
❑
❑
❑
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
0
❑
❑
❑
Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type
0
❑
❑
❑
representative)?
Comment: Time paced composite samples collected at influent (250 ml/20 minutes)
Flow Measurement - Influent
Yes
No
NA
NE
# Is flow meter used for reporting?
❑
0
❑
❑
Is flow meter calibrated annually?
0
❑
❑
❑
Is the flow meter operational?
0
❑
❑
❑
(If units are separated) Does the chart recorder match the flow meter?
0
❑
❑
❑
Comment: Last calibrated on March 2, 2020
Page# 6
Permit: NCO020354 Owner -Facility:
Inspection Date: 07/22/2020 Inspection Type:
Pittsboro WWTP
Compliance Evaluation
Flow Measurement - Effluent
Yes
No
NA
NE
# Is flow meter used for reporting?
0
❑
❑
❑
Is flow meter calibrated annually?
0
❑
❑
❑
Is the flow meter operational?
0
❑
❑
❑
(If units are separated) Does the chart recorder match the flow meter?
0
❑
❑
❑
Comment: Last calibrated on March 2, 2020
Effluent Pipe
Yes
No
NA
NE
Is right of way to the outfall properly maintained?
0
❑
❑
❑
Are the receiving water free of foam other than trace amounts and other debris?
0
❑
❑
❑
If effluent (diffuser pipes are required) are they operating properly?
❑
❑
0
❑
Comment:
Record Keeping
Yes
No
NA
NE
Are records kept and maintained as required by the permit?
0
❑
❑
❑
Is all required information readily available, complete and current?
0
❑
❑
❑
Are all records maintained for 3 years (lab. reg. required 5 years)?
0
❑
❑
❑
Are analytical results consistent with data reported on DMRs?
0
❑
❑
❑
Is the chain -of -custody complete?
0
❑
❑
❑
Dates, times and location of sampling
Name of individual performing the sampling
Results of analysis and calibration
Dates of analysis
Name of person performing analyses
Transported COCs
Are DMRs complete: do they include all permit parameters?
❑
❑
❑
Has the facility submitted its annual compliance report to users and DWQ?
❑
❑
❑
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operatc
❑
❑
0
❑
on each shift?
Is the ORC visitation log available and current?
❑
❑
❑
Is the ORC certified at grade equal to or higher than the facility classification?
❑
❑
❑
Is the backup operator certified at one grade less or greater than the facility classification'
❑
❑
❑
Is a copy of the current NPDES permit available on site?
0
❑
❑
❑
Facility has copy of previous year's Annual Report on file for review?
❑
❑
0
❑
Page# 7
Permit: NC0020354
Inspection Date: 07/22/2020
Record Keeping
Comment:
Aerobic Digester
Is the capacity adequate?
Is the mixing adequate?
Is the site free of excessive foaming in the tank?
# Is the odor acceptable?
# Is tankage available for properly waste sludge?
Owner -Facility: Pittsboro WWTP
Inspection Type: Compliance Evaluation
Yes No NA NE
Yes
No
NA
NE
■
❑
❑
❑
❑
❑
❑
■
■
❑
❑
❑
■
❑
❑
❑
■
❑
❑
❑
Comment: Synagro was hauling sludge from the digesters at the time of inspection, one digester was
empty, the other was being emptied.
Solids Handling Equipment
Is the equipment operational?
Is the chemical feed equipment operational?
Is storage adequate?
Is the site free of high level of solids in filtrate from filter presses or vacuum filters?
Is the site free of sludge buildup on belts and/or rollers of filter press?
Is the site free of excessive moisture in belt filter press sludge cake?
The facility has an approved sludge management plan?
Yes
No
NA
NE
■
❑
❑
❑
■
❑
❑
❑
■
❑
❑
❑
■
❑
❑
❑
■
❑
❑
❑
■
❑
❑
❑
■
❑
❑
❑
Comment: Wasted sludge is thickened by the Parkson rotary drum thickener and then sent to the two
aerobic diaesters.
Comment: Wasted sludge is thickenedThe rotary drum thickener
Chemical Feed
Yes
No
NA
NE
Is containment adequate?
0
❑
❑
❑
Is storage adequate?
0
❑
❑
❑
Are backup pumps available?
0
❑
❑
❑
Is the site free of excessive leaking?
0
❑
❑
❑
Comment: Polvmer feed for sludge thickener: sodium aluminate feed for total phosphorous removal
Equalization Basins
Yes
No
NA
NE
Is the basin aerated?
0
❑
❑
❑
Is the basin free of bypass lines or structures to the natural environment?
0
❑
❑
❑
Is the basin free of excessive grease?
0
❑
❑
❑
Page# 8
Permit: NCO020354
Inspection Date: 07/22/2020
Owner -Facility: Pittsboro WWTP
Inspection Type: Compliance Evaluation
Equalization Basins
Yes
No
NA
NE
Are all pumps present?
0
❑
❑
❑
Are all pumps operable?
0
❑
❑
❑
Are float controls operable?
0
❑
❑
❑
Are audible and visual alarms operable?
M
❑
❑
❑
# Is basin size/volume adequate?
0
❑
❑
❑
Comment: Two EQ basins, 0.3 million -gallon each. One floating aerator in each basin. EQ pump statior
with two pumps right downstream influent Parshall flume. Under normal condition, flow to
aeration basins is set to 0.35 MGD, excessive flow is diverted to EQ basins, and returned to
influent when influent flow is lower than 0.35 MGD
Upstream / Downstream Sampling Yes No NA NE
Is the facility sampling performed as required by the permit (frequency, sampling type, an( ❑ ❑ 0 ❑
sampling location)?
Comment: Member of Upper Cape Fear River Basin Association. Upstream/downstream sampling
conducted by the Association
Pump Station - Influent
Is the pump wet well free of bypass lines or structures?
Is the wet well free of excessive grease?
Are all pumps present?
Are all pumps operable?
Are float controls operable?
Is SCADA telemetry available and operational?
Is audible and visual alarm available and operational?
Comment: Two influent pumps, with one diesel powered bypass pump
Yes No NA NE
❑ ❑ ❑
❑ ❑ ❑
❑ ❑ ❑
■ ❑ ❑ ❑
❑ ❑ ❑
❑ ❑ ❑
❑ ❑ ❑
Page# 9