HomeMy WebLinkAboutNC0020559_WET Inspection_20200825ROY COOPER Governor MICHAEL S. REGAN Secretary S. DANIEL SMITH Director Mr. E. Terrell Blackmon, City Manager City of Henderson P.O. Box 1434 Henderson, NC 27536 NORTH CAROLINA Environmental Quality August 25, 2020 Subject: Bioassay Compliance Evaluation Inspection Whole Effluent Toxicity Test Henderson Water Reclamation Facility NPDES Permit No: NCO020559 / Outfall 001 Vance County Dear Mr. Blackmon: Whole Effluent samples were collected from Henderson Water Reclamation Facility on July 14 and 16, 2020 by Cheng Zhang of Division of Water Resource (DWR), Raleigh Regional Office. These samples were for use in a chronic Ceriodaphnia dubia pass -fail toxicity test, which was performed by the staff at DWR Aquatic Toxicity Branch. This test passed for the toxicity inspection. Toxicity test information follows. Test Type 3-Brood Ceriodaphnia dubia chronic pass fail Test Concentration 90 % Test Result Pass (for Toxicity Inspection) If you have any questions regarding the attached report or any of the findings, please contact Cheng Zhang at: (919) 791-4200 (or email: cheng zhanggncdenr.gov). Sincerely, DocuSigned by: E au�,t,SSa f. haun,� d 62916E6A632144F... Vanessa E. Manuel, Assistant Regional Supervisor Water Quality Regional Operations Section Raleigh Regional Office Division of Water Resources Attachment: EPA Water Compliance Inspection Report Cc: Central Files w/attachment (Laserfiche) Raleigh Regional Office w/attachment D EQ�� North Carolina Department of Environmental Quality I Division of Water Resources Raleigh Regional Office 13800 Barrett Drive I Raleigh, North Carolina 27609 vOry rN Cx:40:.itiA � N. a Io E".w^^�"��a°:r� /� 919.791.4200 United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 2 u 3 I NCO020559 111 121 20/07/14 I17 18 I R I 19 I s I 201 211IIIII 111111III II III III1 I I IIIII IIIIIIIII II r6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 67 70 LJ 71 L72 Ln73 74 79 I I I I 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 10:OOAM 20/07/14 19/08/01 Henderson WRF NC Hwy 39 Exit Time/Date Permit Expiration Date Henderson NC 27536 10:30AM 20/07/14 23/03/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Clarissa M Lipscomb/ORC/252-438-2142/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Terrell Blackmon,PO Box 1434 Henderson NC 27536/City Manager// No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Other Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Cheng Zhang cusignedby: DWR/RRO WQ/919-791-4200/ 8/25/2020 E,1,71508E1EC41F ... Sign [nfcWgRgSBf nt Q A Reviewer Agency/Office/Phone and Fax Numbers Date UAa/lt,SSA DWR/RRO WQ/919-791-4232 8/25/2020 "—B2916E6AB32144F... EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type NCO020559 I11 12I 20/07/14 117 18 IBI Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Two composite samples were collected at Outfall 001 on July 14 and 16, 2020, which were used in a ceriodaphnia chronic pass/fail test at DWR's Aquatic Toxicoly Branch. The test result was PASS. Page#