HomeMy WebLinkAboutSW5200602_Supplement-EZ Form_20200820SUPPLEMENT-EZ COVER PAGE
FORMS LOADED
PROJECT INFORMATION
1 lProiectName
Project Area (ac)
Coastal Wetland Area (ac)
Surface Water Area (ac)
Is this project High or Low Density?
Does this protect use an off -site SCM?
Wake Electric
30
No
COMPLIANCE WITH 02H .1003(4)
7
Width of ve etated setbacks provided feet
8
Will the vegetated setback remain vegetated?
9
Is BUA other that as listed in .1003 4 c-d out of the setback?
10
1 Is streambank stabilization proposed on this project?
NUMBER AND TYPE OF SCMs:
11
Infiltration System
0
12
Bioretention Cell
0
13
Wet Pond
0
14
Stormwater Wetland
0
15
Permeable Pavement
0
16
Sand Filter
2
17
Rainwater Harvesting RWH
0
18
Green Roof
0
19
Level Spreader -Filter Strip LS-FS
2
20
Disconnected Impervious Surface (DIS)
0
21
Treatment Swale
0
22
Dry Pond
0
23
StormFilter
0
24
Silva Cell
0
25
Ba filter
IFilterra
0
26
0
FORMS LOADED
DESIGNER CERTIFICATION
27 Name and Title: Jeff Rice, PE
28
Organization:
Stantec
29
Street address:
2127 Arysley Town Blvd. Suite 300
30
City, State, Zip:
Charlotte, NC 28273
31
Phone numbers :
704-329-0900
32
Email:
Ieff.rice(&stantec.com
Certification Statement:
I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or
supervision; that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and
that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent
with the information provided here.
CARO "."
Ia' 39082
oan4i2o2�
/jrrn11110"�
Seal
Signature of Designer
08/14/2020
Date
DRAINAGE AREAS
1
Is this a high density project?
Yes
2
If so, number of drainage areas/SCMs
2
3
Is all/part of this project subject to previous rule
versions?
No
FORMS LOADED
DRAINAGE AREA INFORMATION
Entire Site
1
2
4
T pe of SCM
Sandfilter/LS-FS
Sandfilter/LS-FS
5
Total BUA in project (sq ft
612789 sf
144687 sf
40758 sf
6
New BUA on subdivided lots (subject to
ermitting) (sq ft
7
New BUA outside of subdivided lots (subject to
ermittin s
185445 sf
144687 sf
40758 sf
8
Offsite -total area (sq ft
9
Offsite BUA (sq ft
10
Breakdown of new BUA outside subdivided lots:
- Parking (sq ft
- Sidewalk (sq ft
1448 sf
1448 sf
- Roof (sq ft
9504 sf
2163 sf
7341 sf
- Roadway s ft
- Future (sq ft
- Other, please specify in the comment box
below (sq ft
174493 sf
141076 sf
33417 sf
11
New infiltrating permeable pavement on
subdivided lots (sq ft
12
New infiltrating permeable pavement outside of
subdivided lots (sq ft
13
Exisitng BUA that will remain (not subject to
ermitting) (sq ft
427334 sf
14
lExistina BUA that is already ermitted (sq ft
15
Existing BUA that will be removed (sq ft
3289 sf
16
Percent BUA
47%
57%
44%
17
Design storm inches
1 in
1 in
18
Design volume of SCM cu ft
8935 cf
2559 cf
19
Calculation method for design volume
simple method
simple method
ADDITIONAL INFORMATION
20
Please use this space to provide any additional information about the
drainage area(s):
gravel and concrete pads..
SAND FILTER
1
IlDrainage area number
1 1
1 2
2
juesign volume o cu
st
Zbbg s
GENERAL
MDC FROM 02H .1050
3
Is the SCM sized to treat the SW from all surfaces at build -out?
Yes
Yes
4
Is the SCM located away from contaminated soils?
Yes
Yes
5
What are the side slopes of the SCM (H:V)?
3:1
3:1
6
Does the SCM have retaining walls, gabion walls or other engineered
side slopes?
No
No
7
Are the inlets, outlets, and receiving stream protected from erosion (10-
year storm)?
Yes
Yes
8
Is there an overflow or bypass for inflow volume in excess of the design
volume?
Yes
Yes
9
What is the method for dewatering the SCM for maintenance?
Drawdown Orifice
Drawdown Orifice
10
If applicable, will the SCM be cleaned out after construction?
No
No
11
Does the maintenance access comply with General MDC (8)?
Yes
Yes
12
Does the drainage easement comply with General MDC (9)?
Yes
Yes
13
If the SCM is on a single family lot, does (will?) the plat comply with
General MDC (10)?
No
No
14
Is there an O&M Agreement that complies with General MDC (11)?
Yes
Yes
15
Is there an O&M Plan that complies with General MDC (12)?
Yes
Yes
16
Does the SCM follow the device specific MDC?
Yes
Yes
17
Was the SCM designed by an NC licensed professional?
Yes
Yes
�Nn FII TFR MOC FROM 07H 1056
18
SHWT elevation (fmsl)
19
Type of sand filter (open or closed)
Open
Open
20
If closed, will the filter will be pre -cast or pour -in -place?
21
If closed, top of grate elevation (fmsl)
22
Is this sand filter designed to attenuate peak flows?
No
No
Sediment Chamber
23
Volume that can be retained in the sediment chamber (cubic feet)
10267 cf
6713 cf
24
Will there be a permanent pool in the sediment chamber?
No
No
25
Bottom of the sediment chamber (fmsl)
442.00
446.00
26
Area of the sediment chamber (square feet)
5337 sf
3685 sf
27
Physical depth of the sediment chamber (inches)
24 in
24 in
28
Ponding depth in the sediment chamber, above any permanent pool
(inches)
24 in
I 24 in
1 448
29
1 Elevation of top of weir between chambers (fmsl)
444
Sand Chamber
30
Volume that can be retained in the sand chamber (cubic feet)
10267 cf
6713 cf
31
Bottom of the sand chamber (fmsl)
439.50
443.50
32
Area of the sand chamber (square feet)
4500 sf
1500 sf
33
Physical depth of the sand chamber (inches)
54 in
54 in
34
Ponding depth in the sand chamber, above any permanent pool
(inches)
24 in
24 in
35
jElevation ofthe bypass device (fmsl)
444
448
36
Type of bypass device
Conc Box Riser
Conc Box Riser
37
Mechanism for distributing flow over the sand surface
Evenly
Evenly
38
Sand specification for sand chamber
ASTM C-33
ASTM C-33
39
Depth above underdrain pipe (inches)
18 in
18 in
40
Will the media be maintained to drain at least two inches per hour at
the sand surface?
Yes
Yes
41
Is at least one clean -out pipe provided at the low point of each
junderdrain line?
Yes
Yes
42
lWill clean -out pipes be capped?
Yes
Yes
ADDITIONAL
INFORMATION
Please use this space to provide any additional information about the
Sand Filter(s):
43
Sand Filter 1 3:58 PM 8/17/2020
LEVEL SPREADER - FILTER STRIP (LS-FS
rainage area number
esign volume of SCM
MDC FROM 02H .1050
3
Is the SCM sized to treat the SW from all surfaces at build -out?
Yes
Yes
4
Is the SCM located away from contaminated soils?
Yes
Yes
5
What are the side slopes of the SCM (H:V)?
20:1
20:1
6
Does the SCM have retaining walls, gabion walls or other engineered
side slopes?
No
No
7
Are the inlets, outlets, and receiving stream protected from erosion
(10-year storm)?
Yes
Yes
8
Is there an overflow or bypass for inflow volume in excess of the
design volume?
Yes
Yes
9
What is the method for dewatering the SCM for maintenance?
Other
Other
10
If applicable, will the SCM be cleaned out after construction?
Yes
Yes
11
Does the maintenance access comply with General MDC (8)?
Yes
Yes
12
Does the drainage easement comply with General MDC (9)?
Yes
Yes
13
If the SCM is on a single family lot, does (will?) the plat comply with
General MDC (10)?
No
No
14
Is there an O&M Agreement that complies with General MDC (11)?
Yes
Yes
15
Is there an O&M Plan that complies with General MDC (12)?
Yes
Yes
16
Does the SCM follow the device specific MDC?
Yes
Yes
17
lWas the SCM designed by an NC licensed professional?
Yes
Yes
LS-FS
MDC FROM 02H .1059
18
Length of level spreader (feet)
40 ft
20 ft
19
Does the LS-IFS receive flow from the drainage area or another
SCM?
Yes
Yes
20
Flow rate to LS-IFS during design storm (cfs)
3 cfs
1 cfs
21
Is a bypass device provided?
No
No
22
If yes, what is the bypass device?
23
Is this LS-IFS designed to receive flow from the drainage area during
the 10-year storm?
yes
yes
24
Has a blind swale been provided?
Yes
Yes
25
Does the blind swale provide for uniform overtopping of the level
spreader?
Yes
Yes
26
What material will be used for the level spreader?
concrete
concrete
27
Will the construction tolerance be < 0.25 inch along the level
spreader length?
Yes
Yes
28
Will the level spreader be straight or convex in plan view?
Yes
Yes
29
Height of the drop from the level spreader to the transition zone
(inches)
3 in
3 in
30
Width of the transition zone (inches)
36 in
36 in
31
Protection for the transition zone
Aggregate
Aggregate
32
Width of the filter strip (feet)
30 ft
30 ft
33
Is the filter strip free of draws and channels?
Yes
Yes
34
Has this been verified in the field?
Yes
Yes
35
Slope of the filter strip (%)
5%
5%
36
Is this slope uniform across the entire filter strip?
Will the first 12" of soil be adjusted if needed to promote plant
growth?
Yes
Yes
37
No
No
38
Will the filter strip and side slopes be planted with non -clumping,
deep-rooted sod?
Yes
Yes
39
Species of sod that will be used
common bermuda
common bermuda
Will soil be temporarily stabilized until permanent vegetation is
40 established?
ADDITIONAL INFORMATION
Please use this space to provide any additional information about the
41 level spreader -filter strip(s):
Yes
Yes
LS-FS 1 4:00 PM 8/17/2020