HomeMy WebLinkAboutNCG210033_DMR_February_20200320 WASTEWATER MANAGEMENT, L.L.C.
P.O. Box 578 Pittsboro, N.C. 27312 (919) 210-2500 Biowater@aol.com
March 10, 2020
Southern Veneer Specialty Products,
Stormwater samples and data was collected from outfalls 1, 3, 4, & 6 on
2/25/20. Lab data is attached. Flow &pH, collected on-site are as
follows:
Rainfall= 1.20"
(pH 7.0 su Standard=7.01 @ 20.1 C @ 10:25)
Outfall pH Flow
#1 7.10 @ 12.2C @ 11.05 100 gpm
#3 6.91 @ 17.4C @ 11:06 4 gpm R�C ��i' �
#4 7.14 @ 18.6C @ 11:21 4 gpm
#6 7.36 @ 18.8C@ 11:57 6 gpm APR 14 2020
CENTRAL FILES
COD (mg/1) DWR SECTION
#1 88
#3 440
#4 37
#6 54
We are pleased to provide you data for this storm water event.
Sincerely,
Randal Jarrell, Environmental Biologist
Semi-annual Stormwater Discharge Monitoring Report
for North Carolina DEMLR General Permit No. NCG210000
Date submitted 3-20-20
=ICATE OF COVERAGE NO. NCG210 0 0 0 SAMPLE COLLECTION YEAR 2020
TY NAME Southern Veneer Specialty Products,L.L.C. SAMPLE PERIOD ❑Jan-June ❑July-Dec
Ty Chatham or ■❑ Monthly' February (month)
IN COLLECTING SAMPLES Randall Jarrell RED` DI$ZN`ARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA
tATORY WM and ENCO Lab Cert. # 5038&591 APR 14 2020 ❑Zero-flow ❑Water Supply ❑SA
rents on sample collection or analysis: ❑Other
CENTRAL FILES
DWR SECTIOM PLEASE REMEMBER TO SIGN ON THE REVERSE -
A: Stormwater Benchmarks and Monitoring Results (Monitoring is required only if the facility stores exposed accumulations of sawdust, wood chips,
mulch, or other similar material on site for longer than seven (7) days.)
■ No discharge this period:
2
Date Sample 24-hour rainfall
Outfall No. 1
Collected amount,
(mo/dd/yr) Inches3 Chemical Oxygen Demand Total Suspended Solids
Benchmarks===> - - 120 mg/L 100 mg/L or 50 mg/L4
#1 2-25-20 1.2 88
#3 2-25-20 1.2 440
#4 2-25-20 1.2 37
#5
#6 2-25-20 1.2 54
thly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall.
3mpling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here.
otal precipitation must be recorded using data from an on-site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement.
ieneral Permit text,Table 3, identifying the especially sensitive receiving water classifications where the more protective benchmark applies.
Results must be reported in numerical format. For example, do not report Below Detection Limit, BDL, <PQL, Non-detect, ND, or other similar non-
ical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L",where XX is the numerical value of the
ion limit, reporting limit, etc. in mg/L.
If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text.
Date:8/1/2018-7/31/2023 SWU-245, last revised 8/6/2018
I: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month.
U No discharge this period?2
•
Date Sample 24-hour rainfall
Outfall No. ,
Collected amount, Non-polar O&G by EPA
(mo/dd/yr) Inches3 1664(SGT-HEM) Total Suspended Solids
Benchmarks===> - - 15 mg/L 100 mg/L or 50 mg/L4
ates from Part A also apply to this Part B
If you report a sample value in excess of the benchmark,you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text.
ART A AND PART B MONITORING RESULTS:
A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B.
2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B.
TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO ■❑
IF YES,HAVE YOU CONTACTED THE DEMLR REGIONAL OFFICE? YES ❑ NO❑
VAL OFFICE CONTACT NAME:
'n original and one copy of this DMR, including all"No Discharge"reports, within 30 days of receipt of the lab results(or at end of monitoring period
case of"No Discharge"reports) to:
in of Water Resources
)WR Central Files
,fail Service Center
h, North Carolina 27699-1617
IUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED:
fy, under penalty of law,that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to
that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system,or
)ersons directly responsible for gathering the information,the information submitted is,to the best of my knowledge and belief,true,accurate,and complete. I
are that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations."
ure of Permittee) (Date)
Date:8/1/2018-7/31/2023 SWU-245, last revised 8/6/2018
CII:CD 4
www.encolabs.com
ANALYTICAL RESULTS
Description: Stormwater#6 Lab Sample ID:CD03430-01 Received: 02/25/20 14:15
Matrix: Water Sampled:02/25/20 10:25 Work Order: CD03430
Project: Southern Veneer Sampled By:RANDALL JARRELL
(Classical Chemistry Parameters
^-ENCO Cary certified analyte[NC 591.7
Analvte fCAS Numberl Results Flaq Units DF MDL POL Batch Method Analyzed Note
Chemical Oxygen Demand^ 54 mg/L 1 10 10 0B27021 SM 5220D-2011 02/27/20 16:40 JOC
Description: Stormwater#4 Lab Sample ID:CD03430-02 Received: 02/25/20 14:15
Matrix: Water Sampled:02/25/20 10:35 Work Order: CD03430
Project: Southern Veneer Sampled By:RANDALL JARRELL
Classical Chemistry Parameters
-ENCO Cary certified analyte[NC 591
Analvte fCAS Numberl Results Flaq Units DF MDL PQL Batch Method Analyzed fly Note:
Chemical Oxygen Demand^ 37 ma/L 1 10 10 0B27021 SM 5220D-2011 02/27/20 16:40 JOC
Description: Stormwater#3 Lab Sample ID:CD03430-03 Received: 02/25/20 14:15
Matrix: Water Sampled:02/25/20 10:40 Work Order: CD03430
Project: Southern Veneer Sampled By:RANDALL JARRELL
Classical Chemistry Parameters
^-ENCO Cary certified analyte[NC 591 j
Analyte fCAS Numberl Results Flaq Units DF MDL PQL Batch Method Analyzed y Note:
Chemical Oxygen Demand^ 440 mg/L 2 20 20 0B27021 SM 5220D-2011 02/27/20 16:40 JOC
Description: Stormwater#1 Lab Sample ID:CD03430-04 Received: 02/25/20 14:15
Matrix: Water Sampled:02/25/20 11:05 Work Order:CD03430
Project: Southern Veneer Sampled By:RANDALL JARRELL
Classical Chemistry Parameters
^-ENCO Cary certified analyte[NC 591]
Analyte fCAS Numberl Results Flaq Units DF MDL PQL Batch Method Analyzed y Note:
Chemical Oxygen Demand^ 88 mg/L 1 10 10 0B27021 SM 5220D-2011 02/27/20 16:40 JOC
FINAL This report relates only to the sample as received by the laboratory,and may only be reproduced in full. Page 4 of 8
p x
Stormwater Discharge Outfall (SDO)
Qualitative Monitoring Report
For guidance on filling out this form,please visit: http://portal.ncdenr.org/web/lr/npdes-stormwater/
Permit No.: N/C/G/ 210000 / /_/ or Certificate of Coverage No.: N/C/G/ / / / / / /
Facility Name: Southern Veneer Specialty Products, L.L.C.
County: Chatham Phone No. 919-275-3249
Inspector: Randall Jarrell
Date of Inspection: 2-25-20
Time of Inspection: 11:05
Total Event Precipitation (inches):_1.2
Was this a "Representative Storm Event" or"Measureable Storm Event"as defined by the permit?
(See information below.)
® Yes ❑ No
Please verify whether Qualitative Monitoring must be performed during a "representative storm
event"or "measureable storm event"(requirements vary, depending on the permit).
Qualitative monitoring requirements vary. Most permits require qualitative monitoring to be
performed during a "representative storm event" or during a "measureable storm event." However,
some permits do not have this requirement. Please refer to these definitions,if applicable.
A"representative storm event"is a storm event that measures greater than 0.1 inches of rainfall
and that is preceded by at least 72 hours (3 days) in which no storm event measuring greater than
0.1 inches has occurred. A single storm event may contain up to 10 consecutive hours of no
precipitation.
A"measurable storm event" is a storm event that results in an actual discharge from the
permitted site outfall. The previous measurable storm event must have been at least 72 hours
prior. The 72-hour storm interval does not apply if the permittee is able to document that a shorter
interval is representative for local storm events during the sampling period,and the permittee
obtains approval from the local DWQ Regional Office.
By this signature, I certify that this report is accurate and complete to the best of my knowledge:
-/4 /Jnee
(Signature of Permittee or I'esi
g )
Page 1 of 2
1. Outfall Description:
Outfall No. 1 Structure (pipe, ditch, etc.) Ditch
Receiving Stream:
Describe the industrial activities that occur within the outfall drainage area:
Wood Production Water
2. Color: Describe the color of the discharge using basic colors (red,brown,blue, etc.) and tint
(light,medium,dark) as descriptors: Slight brownish tint
3. Odor: Describe any distinct odors that the discharge may have (i.e.,smells strongly of oil,
weak chlorine odor,etc.): Normal
4. Clarity: Choose the number which best describes the clarity of the discharge,where 1 is
clear and 5 is very cloudy:
1 2 x3 4 5
5. Floating Solids: Choose the number which best describes the amount of floating solids in
the stormwater discharge,where 1 is no solids and 5 is the surface covered with floating solids:
x1 2 3 4 5
6. Suspended Solids: Choose the number which best describes the amount of suspended
solids in the stormwater discharge,where 1 is no solids and 5 is extremely muddy:
1 x2 3 4 5
7. Is there any foam in the stormwater discharge? Yes xNo
8. Is there an oil sheen in the stormwater discharge? Yes xNo
9. Is there evidence of erosion or deposition at the outfall? Yes xNo
10. Other Obvious Indicators of Stormwater Pollution:
List and describe
Note: Low clarity,high solids,and/or the presence of foam,oil sheen,or erosion/deposition
may be indicative of pollutant exposure. These conditions warrant further investigation.
Page 2 of 2
ice®
N R
Stormwater Discharge Outfall (SDO)
Qualitative Monitoring Report
For guidance on filling out this form,please visit: http://portal.ncdenr.org/web/lr/npdes-stormwater/
Permit No.: N/C/G/ 210000 /_/_/ or Certificate of Coverage No.: N/C/G/ / / / / / /
Facility Name: Southern Veneer Specialty Products, L.L.C.
County: Chatham Phone No. 919-275-3249
Inspector: Randall Jarrell
Date of Inspection: 2-25-20
Time of Inspection: 10:40
Total Event Precipitation (inches):_1.2_
Was this a"Representative Storm Event" or"Measureable Storm Event"as defined by the permit?
(See information below.)
® Yes n No
Please verify whether Qualitative Monitoring must be performed during a "representative storm
event"or"measureable storm event"(requirements vary, depending on the permit).
Qualitative monitoring requirements vary. Most permits require qualitative monitoring to be
performed during a "representative storm event" or during a "measureable storm event." However,
some permits do not have this requirement. Please refer to these definitions,if applicable.
A"representative storm event"is a storm event that measures greater than 0.1 inches of rainfall
and that is preceded by at least 72 hours (3 days) in which no storm event measuring greater than
0.1 inches has occurred. A single storm event may contain up to 10 consecutive hours of no
precipitation.
A"measurable storm event" is a storm event that results in an actual discharge from the
permitted site outfall. The previous measurable storm event must have been at least 72 hours
prior. The 72-hour storm interval does not apply if the permittee is able to document that a shorter
interval is representative for local storm events during the sampling period,and the permittee
obtains approval from the local DWQ Regional Office.
By this signature, I certify that this report is accurate and complete to the best of my knowledge:
(Signature of Permittee or Designee)
Page 1 of 2
1. Outfall Description:
Outfall No. 3 Structure (pipe, ditch, etc.) Ditch
Receiving Stream:
Describe the industrial activities that occur within the outfall drainage area:
Wood Production Water
2. Color: Describe the color of the discharge using basic colors (red,brown, blue, etc.) and tint
(light,medium,dark) as descriptors: Slight greyish tint
3. Odor: Describe any distinct odors that the discharge may have(i.e.,smells strongly of oil,
weak chlorine odor, etc.): Slightly Musty
4. Clarity: Choose the number which best describes the clarity of the discharge,where 1 is
clear and 5 is very cloudy:
1 2 x3 4 5
5. Floating Solids: Choose the number which best describes the amount of floating solids in
the stormwater discharge,where 1 is no solids and 5 is the surface covered with floating solids:
x1 2 3 4 5
6. Suspended Solids: Choose the number which best describes the amount of suspended
solids in the stormwater discharge,where 1 is no solids and 5 is extremely muddy:
1 x2 3 4 5
7. Is there any foam in the stormwater discharge? Yes xNo
8. Is there an oil sheen in the stormwater discharge? Yes xNo
9. Is there evidence of erosion or deposition at the outfall? Yes xNo
10. Other Obvious Indicators of Stormwater Pollution:
List and describe
Note: Low clarity,high solids,and/or the presence of foam,oil sheen,or erosion/deposition
may be indicative of pollutant exposure. These conditions warrant further investigation.
Page 2 of 2
M
Stormwater Discharge Outfall (SDO)
Qualitative Monitoring Report
For guidance on filling out this form,please visit: http://portal.ncdenr.org/web/lr/npdes-stormwater/
Permit No.: N/C/G/ 210000 / /_/ or Certificate of Coverage No.: N/C/G/ / / / / / /
Facility Name: Southern Veneer Specialty Products, L.L.C.
County: Chatham Phone No. 919-275-3249
Inspector: Randall Jarrell
Date of Inspection: 2-25-20
Time of Inspection: 10:35
Total Event Precipitation (inches):_1.2
Was this a "Representative Storm Event" or"Measureable Storm Event"as defined by the permit?
(See information below.)
Yes n No
Please verify whether Qualitative Monitoring must be performed during a "representative storm
event"or"measureable storm event"(requirements vary, depending on the permit).
Qualitative monitoring requirements vary. Most permits require qualitative monitoring to be
performed during a "representative storm event" or during a "measureable storm event." However,
some permits do not have this requirement. Please refer to these definitions, if applicable.
A"representative storm event" is a storm event that measures greater than 0.1 inches of rainfall
and that is preceded by at least 72 hours (3 days) in which no storm event measuring greater than
0.1 inches has occurred. A single storm event may contain up to 10 consecutive hours of no
precipitation.
A"measurable storm event"is a storm event that results in an actual discharge from the
permitted site outfall. The previous measurable storm event must have been at least 72 hours
prior. The 72-hour storm interval does not apply if the permittee is able to document that a shorter
interval is representative for local storm events during the sampling period, and the permittee
obtains approval from the local DWQ Regional Office.
By this signature, I certify that this report is accurate and complete to the best of my knowledge:
(Signature of Permittee or Designee)
Page 1 of 2
1. Outfall Description:
Outfall No.4 Structure (pipe, ditch, etc.) Ditch
Receiving Stream:
Describe the industrial activities that occur within the outfall drainage area:
Wood Production
2. Color: Describe the color of the discharge using basic colors (red,brown,blue, etc.) and tint
(light,medium,dark) as descriptors: Slight yellow tint
3. Odor: Describe any distinct odors that the discharge may have (i.e.,smells strongly of oil,
weak chlorine odor, etc.): Normal
4. Clarity: Choose the number which best describes the clarity of the discharge,where 1 is
clear and 5 is very cloudy:
x1 2 3 4 5
5. Floating Solids: Choose the number which best describes the amount of floating solids in
the stormwater discharge,where 1 is no solids and 5 is the surface covered with floating solids:
x1 2 3 4 5
6. Suspended Solids: Choose the number which best describes the amount of suspended
solids in the stormwater discharge,where 1 is no solids and 5 is extremely muddy:
1 x2 3 4 5
7. Is there any foam in the stormwater discharge? Yes xNo
8. Is there an oil sheen in the stormwater discharge? Yes xNo
9. Is there evidence of erosion or deposition at the outfall? Yes xNo
10. Other Obvious Indicators of Stormwater Pollution:
List and describe
Note: Low clarity,high solids,and/or the presence of foam,oil sheen,or erosion/deposition
may be indicative of pollutant exposure. These conditions warrant further investigation.
Page 2 of 2
WDEN441
Stormwater Discharge Outfall (SDO)
Qualitative Monitoring Report
For guidance on filling out this form,please visit: http://portal.ncdenr.org/web/lr/npdes-stormwater/
Permit No.: N/C/G/210000 /_/_/ or Certificate of Coverage No.: N/C/G/ / / / / / /
Facility Name: Southern Veneer Specialty Products, L.L.C.
County: Chatham Phone No. 919-275-3249
Inspector: Randall Jarrell
Date of Inspection: 2-25-20
Time of Inspection: 10:25
Total Event Precipitation (inches):_1.2
Was this a "Representative Storm Event" or"Measureable Storm Event"as defined by the permit?
(See information below.)
® Yes n No
Please verify whether Qualitative Monitoring must be performed during a "representative storm
event"or"measureable storm event"(requirements vary, depending on the permit).
Qualitative monitoring requirements vary. Most permits require qualitative monitoring to be
performed during a "representative storm event" or during a "measureable storm event." However,
some permits do not have this requirement. Please refer to these definitions, if applicable.
A"representative storm event"is a storm event that measures greater than 0.1 inches of rainfall
and that is preceded by at least 72 hours (3 days) in which no storm event measuring greater than
0.1 inches has occurred. A single storm event may contain up to 10 consecutive hours of no
precipitation.
A"measurable storm event" is a storm event that results in an actual discharge from the
permitted site outfall. The previous measurable storm event must have been at least 72 hours
prior. The 72-hour storm interval does not apply if the permittee is able to document that a shorter
interval is representative for local storm events during the sampling period,and the permittee
obtains approval from the local DWQ Regional Office.
By this signature, I certify that this report is� accurate and complete to the best of my knowledge:
/2„,
(Signature of Permittee or Designee)
Page 1 of 2
1. Outfall Description:
Outfall No. 6 Structure (pipe, ditch, etc.) Ditch
Receiving Stream:
Describe the industrial activities that occur within the outfall drainage area:
Wood Production Water
2. Color: Describe the color of the discharge using basic colors (red,brown,blue, etc.) and tint
(light,medium,dark) as descriptors: Light Clear
3. Odor: Describe any distinct odors that the discharge may have(i.e.,smells strongly of oil,
weak chlorine odor, etc.): Normal
4. Clarity: Choose the number which best describes the clarity of the discharge,where 1 is
clear and 5 is very cloudy:
xl 2 3 4 5
5. Floating Solids: Choose the number which best describes the amount of floating solids in
the stormwater discharge,where 1 is no solids and 5 is the surface covered with floating solids:
x1 2 3 4 5
6. Suspended Solids: Choose the number which best describes the amount of suspended
solids in the stormwater discharge,where 1 is no solids and 5 is extremely muddy:
1 x2 3 4 5
7. Is there any foam in the stormwater discharge? Yes xNo
8. Is there an oil sheen in the stormwater discharge? Yes xNo
9. Is there evidence of erosion or deposition at the outfall? Yes xNo
10. Other Obvious Indicators of Stormwater Pollution:
List and describe
Note: Low clarity,high solids,and/or the presence of foam,oil sheen,or erosion/deposition
may be indicative of pollutant exposure. These conditions warrant further investigation.
Page 2 of 2
i
CDENR
Stormwater Discharge Outfall (SDO)
Qualitative Monitoring Report
For guidance on filling out this form,please visit: http://portal.ncdenr.org/web/lr/npdes-stormwater/
Permit No.: N/C/G/ 210000 /_/ / or Certificate of Coverage No.: N/C/G/ / / / / / /
Facility Name: Southern Veneer Specialty Products, L.L.C.
County: Chatham Phone No. 919-275-3249
Inspector: Randall Jarrell
Date of Inspection: 2-25-20
Time of Inspection: 11:10
Total Event Precipitation (inches):_1.2
Was this a"Representative Storm Event" or"Measureable Storm Event"as defined by the permit?
(See information below.)
® Yes ❑ No
Please verify whether Qualitative Monitoring must be performed during a "representative storm
event"or"measureable storm event"(requirements vary, depending on the permit).
Qualitative monitoring requirements vary. Most permits require qualitative monitoring to be
performed during a "representative storm event" or during a "measureable storm event." However,
some permits do not have this requirement. Please refer to these definitions,if applicable.
A"representative storm event"is a storm event that measures greater than 0.1 inches of rainfall
and that is preceded by at least 72 hours (3 days) in which no storm event measuring greater than
0.1 inches has occurred. A single storm event may contain up to 10 consecutive hours of no
precipitation.
A"measurable storm event" is a storm event that results in an actual discharge from the
permitted site outfall. The previous measurable storm event must have been at least 72 hours
prior. The 72-hour storm interval does not apply if the permittee is able to document that a shorter
interval is representative for local storm events during the sampling period,and the permittee
obtains approval from the local DWQ Regional Office.
By this signature, I certify that this report is accurate and complete to the best of my knowledge:
j4,,,z,„<pd
(Signature of Permittee or Designee)
Page 1 of 2
1. Outfall Description:
Outfall No. 5 Structure (pipe, ditch, etc.) Ditch
Receiving Stream:
Describe the industrial activities that occur within the outfall drainage area:
Wood Production
2. Color: Describe the color of the discharge using basic colors (red,brown,blue, etc.) and tint
(light, medium,dark) as descriptors: Slight yellow tint
3. Odor: Describe any distinct odors that the discharge may have (i.e.,smells strongly of oil,
weak chlorine odor, etc.): Normal
4. Clarity: Choose the number which best describes the clarity of the discharge,where 1 is
clear and 5 is very cloudy:
xl 2 3 4 5
5. Floating Solids: Choose the number which best describes the amount of floating solids in
the stormwater discharge,where 1 is no solids and 5 is the surface covered with floating solids:
xl 2 3 4 5
6. Suspended Solids: Choose the number which best describes the amount of suspended
solids in the stormwater discharge,where 1 is no solids and 5 is extremely muddy:
1 x2 3 4 5
7. Is there any foam in the stormwater discharge? Yes xNo
8. Is there an oil sheen in the stormwater discharge? Yes xNo
9. Is there evidence of erosion or deposition at the outfall? Yes xNo
10. Other Obvious Indicators of Stormwater Pollution:
List and describe
Note: Low clarity,high solids,and/or the presence of foam,oil sheen, or erosion/deposition
may be indicative of pollutant exposure. These conditions warrant further investigation.
Page 2 of 2
SV SW Tier III Storm Water Management Inspection Outfall#1
Inspection Date: 2-25-19, 11:10 AM
Analysis Received—3/10/20
Benchmark Value Exceeded—No
Inspector—Randall Jarrell
Action—Sample point needs to be moved downstream of all discharge points.
Action Date-asap
SV SW Tier III Storm Water Management Inspection Outfall#3
Inspection Date: 2-25-19, 10:40 AM
Analysis Received—3-10-25
Benchmark Value Exceeded—yes
Inspector—Randall Jarrell
Action—Rotate bark pile at hammer hog
Action Date—asap
SV SW Tier III Storm Water Management Inspection Outfall#4
Inspection Date: 2-25-19, 10:35 AM
Analysis Received—3-10-20
Benchmark Value Exceeded—No
Inspector—Randall Jarrell
Action—Monitoring
Action Date—Ongoing
SV SW Tier III Storm Water Management Inspection Outfall#5
Inspection Date: 2-25-19, 11:10 AM
Analysis Received—3-10-20
Benchmark Value Exceeded—No
Inspector—Randall Jarrell
Action—Monitoring
Action Date - Ongoing
SV SW Tier III Storm Water Management Inspection Outfall#6
Inspection Date: 2-25-20 10:25 AM
Analysis Received—3-10-25
Benchmark Value Exceeded—No
Inspector—Randall Jarrell
Action—Monitoring. Keep rip rap dams cleaned.
Action Date—Ongoing