Loading...
HomeMy WebLinkAboutWQ0041836_Final Permit_20200818a � tirw STATE", n Roy COOPER Le a Z r Governor MICHAEL S. REGAN Secretary Y"" S. DANIEL SMITH NORTH CAROLINA Director Environmental Quality August 18, 2020 Todd Taylor, P.E., Executive Director Orange Water & Sewer Authority 400 Jones Ferry Road Carrboro, NC 27510 Subject: Permit No. WQ0041836 Orange Water & Sewer Authority Habitat for Humanity Sanitary Sewer Extension Wastewater Collection System Extension Permit Orange County Dear Mr. Taylor: In accordance with your application received July 14, 2020, and additional information received on August 10, 2020, we are forwarding herewith Permit No. WQ0041836 dated August 18, 2020 to the Orange Water & Sewer Authority (Permittee) for the construction and operation upon certification of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to the following conditions contained within this permit: Condition 11.1: This permit shall not be automatically transferable; a request must be made and approved. Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 02T .0403 or any individual system -wide collection system permit issued to the Permittee. Condition 11.7: Upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form with checklist attached to this permit shall be submitted with the required supporting documents to the address provided on the form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations, or the Minimum Design Criteria. [15A NCAC 02T.0116] It shall be responsibility of the Permittee to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. North Carolina Department of Environmental Quality Division of Water Resourcc� Raleigh Reqlonal Office 3800 Barrett Drive Raleluh, North Carolina 27009 Orange Water & Sewer Authority Permit No. WQ0041836 If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150E of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Ted Cashion at (919) 791-4254 or via e-mail at ted.cashion@ncdenr.gov. Sincerely, olzevn for S, Daniel Smith Director, Division of Water Resources by Scott Vinson, Regional Supervisor Water Quality Regional Operations Section Raleigh Regional Office Division of Water Resources, NCDEQ cc: William Akin, P.E., Civil Consultants, Inc. (randy.akin@civil-consultants.com) Jessica Godreau, OWASA Nick Parker, OWASA Joe Leo, OWASA Regional Office Files Water Resources Central Files PERCS (electronic copy) Victoria Hudson, Orange County Health Department NORTH CAROLINA Enviranmenfal Qualify WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the Orange Water & Sewer Authority Orange County for the construction and operation of approximately 305 linear feet of 8-inch gravity sewer to serve a residential project as part of the Habitat for Humanity Sanitary Sewer Extension project, and the discharge of no additional gallons per day of collected wastewater (flow will be allocated in future permit applications) into the Orange Water & Sewer Authority's existing sewerage system, pursuant to the application received July 14, 2020, and additional information received on August 10, 2020 and in conformity with 15A NCAC 02T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting data subsequently filed and approved by the Department of Environmental Quality and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded and shall be subject to the specified conditions and limitations contained therein. for S. Daniel Smith Director, Division of Water Resources By Authority of The Environmental Management Commission Permit Number: WQ0041836 Permit Issued: August 18, 2020 Page 3 of 8 SUPPLEMENT TO PERMIT COVER SHEET Orange Water & Sewer Authority is hereby authorized to: Construct, and then operate upon certification the aforementioned wastewater collection extension. The sewage and wastewater collected by this system shall be treated in the Mason Farm Wastewater Treatment Facility in accordance with Permit Number NC0025241. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A NCAC 02T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Construction and operation is contingent upon compliance with the Standard Conditions and any Special Conditions identified below. I. SPECIAL CONDITIONS NONE II. STANDARD CONDITIONS 1. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. [15A NCAC 02T.0116; G.S 143-215.1(d3)] 2. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 02T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials unless specifically mentioned herein. [15A NCAC 02T.0110] 3. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. [15A NCAC 02T .0110] 4. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 02T .0403. If an individual permit is not required, the following performance criteria shall be met: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. Page 4 of 8 b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six -months and inspections are documented. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. h. A Grease Control Program is in place as follows: 1. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. Z. For privately owned collection systems, the Grease Control Program shall include at least bi- annual distribution of grease education materials to users of the collection system by the permittee or its representative. 3. Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows. L Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility. j. Documentation shall be kept for Subparagraphs (a) through (i) of this Rule for a minimum of three years with exception of the map, which shall be maintained for the life of the system. 5. The Permittee shall report by telephone to a water resources staff member at the Raleigh Regional Office, telephone number (919) 791-4200, as soon as possible, but in no case more than 24 hours, following the occurrence or first knowledge -of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any SSO and/or spill over 1,000 gallons; or c. Any SSO and/or spill, regardless of volume, that reaches surface water Voice mail messages or faxed information is permissible, but this shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing and submitting Part I of Form CS-SSO (or the most current Division approved form) within five days following first Page 5 of 8 knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Part 11 of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. [G.S. 143-215.1C(a1)] 6. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. [15A NCAC 02T.0108(b)] 7. Upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form with checklist attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. if the permit is issued to a private entity with an Operational Agreement, then a copy of the Articles of Incorporation, Declarations/Covenants/Restrictions, and Bylaws that have been appropriately filed with the applicable County's Register of Deeds office shall be submitted with the certification. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Supporting documentation shall include the following: a. One copy of the project construction record drawings (plan & profile views of sewer lines & force mains) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CD or DVD disk) and are defined as the design drawings that are marked up or annotated with after construction information and show required buffers, separation distances, material changes, etc. b. One copy of the supporting applicable design calculations including pipe and pump sizing, velocity, pump cycle times, and level control settings, pump station buoyancy, wet well storage, surge protection, detention time in the wet well, and force main, ability to flush low points in force mains with a pump cycle, and downstream sewer capacity analysis. If a portable power source or pump is dedicated to multiple stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, include travel timeframes, shall be provided. c. Changes to the project that do not result in noncompliance with this permit, regulations, or the Minimum Design Criteria should be clearly identified on the record drawings, on the certification in the space provided, or in written summary form. Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in non-compliance with this permit (including but not limited to pipe length changes of 10% or greater, increased flow, pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by - case basis and each on its own merit. Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After - Page 6 of 8 construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. [15A NCAC 02T .0116] 8. Gravity sewers installed greater than ten percent below the minimum required slope per the Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until corrected. If there is an unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested from the Division with firm supporting documentation. This shall be done through a permit modification with fee. Such variance requests will be evaluated on a case -by -case basis. Resolution of such request shall be evident prior to completing and submitting the construction certification. [ 15A NCAC 02T.0105(n)] 9. A copy of the individual permit and construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. [15A NCAC 02T .0116] 10. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 02T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143-215.6A through §143- 215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. [15A NCAC 02T .0108(b-c)] 11. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. [15A NCAC 02T .0110; 15A NCAC 02T .0108(b)] 12. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by the Division any other Federal, State, or Local government agencies which have jurisdiction or obtaining other permits which may be required by the Division or any other Federal, State, of Local government agencies. [G.S. 143-215.1(b)] Page 7 of 8 CERTIFICATION CHECKLIST To be completed by the certifying engineer prior to operation of the permitted sewers, per 15A NCAC 02T.0116. Certifying Engineer: Certification Review Date: Project Name: WQOQ Project County: 1) Has permittee information changed since the permit was issued (or last modified): change of mailing address, change of ownership, transfer from developer to HOA/POA, etc. ❑ Yes ❑ No • If yes, please provide either a change of ownership form or new contact information. Note that transfer of permits from the developer to the HOA/POA must occur with the first certification. 2) Have the as -built drawings have been signed, sealed, and dated by an N.C. PE? ❑ Yes ❑ No 3) Final Engineering certification? ❑ Yes ❑ No • If Partial Engineering certification, provide detailed narrative including what is being certified in the current phase, what was previously certified (if applicable), and what is left to be certified. 4) Adequate information related to sewer lines: ❑ Yes ❑ No ❑ N/A Three feet minimum cover has been provided for all sewers unless ferrous pipe was installed. Minimum diameters for gravity sewers are 8-inches for public lines and 6-inches for private lines. Manholes have been installed: At the end of each line, at all changes in grade, size, or alignment, at all intersections, and at distances not greater than 425 feet; minimum diameter shall be 4 feet (48-inches). 5) Adequate information related to pump stations: ❑ Yes ❑ No ❑ N/A • Ensure power reliability option was selected per 15A NCAC 02T.0305(h). 6) Was project construction completed in accordance with all of the following: ❑ Yes ❑ No ❑ N/A • 15A NCAC 02T, Minimum Design Criteria (MDC) for the Permitting of Gravity Sewers (latest version), and MDC for the Permitting of Pump Stations and Force Mains (latest version)? If not, a variance approval is required in accordance with 15A NCAC 02T.0105 b prior to certification and operation. • Contact the Central Office to discuss the variance to determine a course of action. • Applicant must submit two copies of the variance request form, plans, specifications, calculations, and any other pertinent information to the Central Office (one hard copy, one digital copy). • The central office will review the variance request, and if approvable, specific language regarding the variance will be incorporated into the permit, either via a special condition or a supplementary letter. A copy of the reissued permit with variance language or the variance letter must be maintained with the original documents. 7) Does the project contains high priority lines (15A NCAC 02T .0402(2))? ❑ Yes ❑ No • If yes, ensure that the permit already contains the necessary condition related to high priority lines 15A NCAC 02T.0403 (a)(5). If the permit does not include this language, the Fast Track reviewer will reissue the permit with the appropriate language. 8) Are Permit modifications are required for any changes resulting in non-compliance with this permit (including but not limited to pipe length changes of 10`Yo or greater, change in flow, pump station design capacity design change of 5% or greater, and/or change in the number/type of connections)? ❑ Yes ❑ No • If yes, a permit modification request must be submitted to the appropriate Regional Office, and a modified permit with revised certification must be issued prior to certification and operation. North Carolina Department of Environmental Quality Division of Water Resources Raleigh Reg anal Office 1628 Mail Service Center, Raleigh, NC 27699-1628 PhvSlfal AdrtrP.SS' 3800RArrPtt DrivF- Ralmoh Nr' ?7Fing g14.7g1.4 )nn FAST TRACK SEWER ENGINEERING CERTIFICATION PERM17TEE: Orange Water & Sewer Authority PERMIT #: WQ0041836 PROJECT: Habitat for Humanity Sanitary Sewer Extension ISSUE DATE: August 18, 2020 This project shall not be considered complete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this Certification and all required supporting documentation. It should be submitted in a manner that documents the Division's receipt. Send the required documentation the Regional Supervisor, Water Quality Regional Operations Section at the address at the bottom. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. The Permittee is responsible for tracking all partial certifications up until a final certification is received. A Final Certification shall be a complete set of record drawings and design calculations regardless of whether partials have been submitted. PERMITTEE'S CERTIFICATION I, the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof. Printed Name, Title Signature Date ENGINEER'S CERTIFICATION I, , as a duI registered Professional En ineer in the State of North Carolina, having been authorized to observe ([periodically, ❑ weekly, full time) the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the following construction: approximately 305 linear feet of 8-inch gravity sewer, such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T, the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's Seal w/signature & date: ❑ Final ❑ Partial (include description) Certification Comments/Qualifiers (attach if necessary): North Carolina Department of Environmental Qua ity Divas on of Water Resources Raleigh Regional Office 1 1628 Mai Service Center, Ralr.�gh, NC 27699.1.628 State of North Carolina DWR Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEMENTENSION APPLICATION Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: Vii/q 00 to bo completed b% DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: `Q 1. Applicant's name: Orange Water & Sewer Authority (company, municipality, I-IOA, utility, etc.) K G pPee i y # ` " 2. Applicant type: ❑ Indi%idual ❑ Corporation ❑ General Partnership ❑ I ' ately-Owned Public Utility ❑ Federal ❑ StaterCounty ❑ Municipal ® Other 3. Signature authority's name: Todd Taylor PE per 15A NCAC 02T .01061 h) Title: Executive Director 4. Applicant's mailing address: 400 Jones Fern Road City: Carrboro State: NC Zip: 27510-_ 5. Applicant's contact information: Phone number: (919) 537-4201 Email Address: nnarker i'owasa.org II. PROJECT INFORMATION: Z C) 1. Project name: Habitat fir Hurt anity Sanitar% Sewer Extension 91 d 2. Application+Project status: ® Proposed (New Permit) ❑ Existing Permit/Projectgo W �0 If a modification. provide the existing permit number: WQOO and issued date. t� r If new construction but part of a master plan. pro% ide the existing permit number: WQOO 15• 3. County where project is located: Orange iu 3 4. Approximate Coordinates (Decimal Degrees): Latitude:35.965087" Longitude:-79.028125- O c 5. Parcel ID (if applicable): Parcel ID downstream NC Dept of Environmental Quality n A (or to closest sewer) III. CONSULTANT INFORMATION: JUL 2 I 2020 L,/ 1. Prolessional Engineer: William Akin. PE License Number: 45959 Q ��J� y f� Firm: Civil Consultants. Inc Mailing address: 3708 Lvckan Parkway Suite 201 Q City: Durham State: NC Zip: 27707-� Phone number: (919) 490-1645 Email Address: randv.akinircivil-consul tan ts.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Mason Farm Wastewater Treatment Plant Permit Number: NC 0025241 Owner Name: O WASA V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): I. Permit Number(s): WQ NA -'87 installation Downstream (Receiving) Sewer Size: 8 inch System Wide Collection System Permit Number(s) (if applicable): WQCS00031 O%%ner Name(s): Orange Water & Sewer Authority FORM: FTA 04-16 Page I of THE COMPLETED APPLICATION PACKAGE INCLDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE: REGIONAL OFFICE ADDRESS COUNTIES SERVED Asheville Regional Office 2090 US Highway 70 Avery, Buncombe, Burke, Caldwell, Cherokee, Water Quality Section Swannanoa, North Carolina 28778 Clay, Graham, Haywood, Henderson, Jackson, (828) 296-4500 Macon, Madison, McDowell, Mitchell, Polk, (828) 299-7043 Fax Rutherford, Swain, Transylvania, Yancey Fayetteville Regional Office 225 Green Street Suite 714 Anson, Bladen, Cumberland, Harnett, Hoke, Water Quality Section Fayetteville, North Carolina 28301-5094 Montgomery, Moore, Robeson, Richmond, (910) 433-3300 Sampson, Scotland (910) 486-0707 Fax Mooresville Regional Office 610 E. Center Avenue Alexander, Cabarrus, Catawba, Cleveland, Water Quality Section Mooresville, North Carolina 28115 Gaston, Iredell, Lincoln, Mecklenburg, Rowan, (704) 663-1699 Stanly, Union (704) 663-6040 Fax Raleigh Regional Office 1628 Mail Service Center Chatham, Durham, Edgecombe, Franklin, Water Quality Section Raleigh, North Carolina 27699-1628 Granville, Halifax, Johnston, Lee, Nash, (919) 791-4200 Northampton, Orange, Person, Vance, Wake, (919) 788-7159 Fax Warren, Wilson Washington Regional Office 943 Washington Square Mall Beaufort, Bertie, Camden, Chowan, Craven, Water Quality Section Washington, North Carolina 27889 Currituck, Dare, Gates, Greene, Hertford, Hyde, (252) 946-6481 Jones, Lenoir, Martin, Pamlico, Pasquotank, (252) 975-3716 Fax Perquimans, Pitt, Tyrrell, Washington, Wayne Wilmington Regional Office 127 Cardinal Drive Extension Brunswick, Carteret, Columbus, Duplin, New Water Quality Section Wilmington, North Carolina 28405 Hanover, Onslow, Pender (910) 796-7215 (910) 350-2004 Fax Winston-Salem Regional Office 450 W. Hanes Mill Road Alamance, Alleghany, Ashe, Caswell, Davidson, Water Quality_ Sect ion Suite 300 Davie, Forsyth, Guilford, Rockingham, Randolph, Winston-Salem North Carolina 27105 Stokes, Surry, Watauga, Wilkes, Yadkin (336)776-9800 INSTRUCTIONS FOR FORM: FTA 04-16 K SUPPORTING DOCUNIENTATION Page 3 of') V1. GENERAL REQUIREMENTS I. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes [:]No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developers Operational Agreement ( FORM: DI=V) been attached? ❑ Yes ❑No ®N/A 3. If the Applicant is a llomelPropertw Owners' Association. has an Operational Agreement (FORM: 11(7A) been attached? ❑ Yes ❑No ®NIA 4. Origin of wastewater: (check all that apply): Not Applicable - Flow to be allocated for future upstream development ❑Residential Owned ❑Retail (stores, centers, malls) ❑Car Wash ❑Residential Leased ❑Retail with food preparation?service 01-lotel and;or Motels ❑ School 1 preschool � day care ❑Medical i dental i veterinary facilities ❑Swimming Pool ; Clubhouse ❑Food and drink facilities ❑Church ❑Swimming Pool"Filter Back%%ash ❑ Businesses,' offices? factories ❑Nursing Ilome ❑Other (Explain in Attachment) 5. Nature of wastewater : % Domestic.. -Commercial % Commercial _ % Industrial (flee 15A NCAC 02"I' _01103(20)) bIs there a Pretreatment Program in effect'? ❑ Yes ® No 6. Has a flow reduction been approved under 15.4 NCAC 021- ,; 0114(t)? [-]Yes ®No ;- If yes. provide a co v of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.011411)) Daily Design Flow "'b No. of Units Flow gale GPD gal' GPD gal' GPD gal/ GPD e& GPD gal.. GPD Toga! GPD a See 15A NCAC 02T .0114(h). (d). (c)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or cast of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(e), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns. and other measured data. 8. Wastewater generated b% project: 0 GPD (per I3A NCAC 02T .01 Id) i Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑Flow has already been allocated in Permit Number: ❑Rehabilitation or replacement of existing sewer with no new flow expected ®Other (Explain):Residential flow will be covered under future fast track permit application. FORM: FTA 04-16 Page 2 of 5 VII. GRAVITV SEWER DESIGN CRITERIA (If Applicable) - 02T .0305&NIDC (Gravity Sewers): I. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 305 8 DIP Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria Section III contains information related to minimum slopes for gravity sewer(s) Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC Vill. PUMP STATION DESIGN CRITERIA (If Applicable)-02T .0305&MDC (Puma Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - 3. Design floe of the pump station: millions gallons per day ( firm capacity) 4. Operational point(s) of the pump(s): _ gallons per minute at feet total dynamic head (TDI-1) 5. Summarize the force main to be permitted ( for this Pump Station): Size (inches) Length (feet) Material 6. Power reliabilityin accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or pump with automatic actuation and telemetry - 15A NCAC 02T .0305(h)(1)(13): Required for all pump stations with an a,,crage daily flow greater than or equal to 13,000 gallons per day > Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation. quick -connection receptacle and telemetry - 15A NCAC 02T _0305(h)(l)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): :- It shall be demonstrated to the Di%ision that the portable source is owned or contracted by the applicant (draft agreement) and is compatible %%ith thestation. If the portable power source or pump is dedicated to multiple pump stations, anevaluation of all the pump stations` storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. 17ORM: FTA 04-16 Page 3 of IN. SETBACKS & SEPARATIONS — (02B.0200&15A NCAC 02T.0305(f)): I. Does the project comply with all separations found in 15A NCAC 02T .0305 t & g I3A NCAC 02T.0305(I) contains minimum separations that shall be nrovided for sewer systems: ® Yes ❑ No Setback Parameter* Separation Required Storm servers and other utilities not listed below (vertical) 24 inches Water mains ( vertical -water over sewer including in benched trenches) 18 inches Water mains (horizontal) l0 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-1 haters of Class I or Class II impounded reservoirs used as a source of drinkin& water 100 feet **Waters classified WS (except WS-I or WS-V). B. SA. ORW, FIQW, or SB from normal high water (or tide elevation) and wetlands (sec item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Anv basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainages stems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade(vertical) 36 inches 15A NCAC 02T.0305(g) contains alternatives where separations in 02'I'.0305(f) cannot be achieved. *"Stream classifications can be identi lied using the Division's NC Surface Water Classifications wehyge If noncompliance with 02T.0303 1 or g .see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 lect of separation) ® Yes [:]No See the Division's draft separation requirements for situations %%here separation cannot be meet No variance is required if the alternative design criteria specified is utilized in design and construction As built documents should reference the location of areas effected 3. Does the project comply with all setbacks found in the river basin rules per 15A NCAC 02B .0200? ® Yes ❑ No This would include Trout Buffered Streams per I5A NCAC 2B.0202 4. Does the project comply with an individual 404 Permit or any 401 Certifications? ® Yes [:]No Wetland -related permits shall be requested, obtained, and adhered to for projects that impact wetlands or surface waters Y Information can be obtained from the 401 & Buffer Permitting Branch 5. Does project comply with 15A NCAC 02T.0 105(cli 6) (additional permitsicertifications)? ®Yes ❑ No Per 15A NCAC 02 r.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or harc been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans. etc.)_ 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 021'.0402, -high-priority sewer' means "any aerial sewer, sewer contacting surface waters, siphon. or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Ycs ® No :- If }es, include an attachment with details for each line, including t) pe (aerial line, size, material. and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per ISA NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with I5A NCAC 021', the Minimum Desien Criteria liar the Permitting of Pump Stations and Force plains (latest version)_ and the Corm it% Sewer Minimum Desien Criteria I latest version as applicable? ❑ Yes ❑ No IfNo. complete and submit the Variance' 'Alternative Design Request application (VADC 10-1/4) and supporting documents for review.A roval of the request is re uired prior to submittal of the Fast Track Application and su ortin documents. 2, Professional Engineer's Certification: I William Akin, PE (Professional Engineer's name from Application Item 111.1.) attest that this application far has been reviewed by me and is accurate, complete and consistent with the iniormation supplied in the plans. specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I t'urther attest that to the best of my knowledge the proposed design has been prepared in accordance vvith the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other protessionals may have der eloped certain portions ofthis submittal package. inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE— In accordance with General Statutes 143-215.6A and 143-215.613. any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10.000, as well as civil penalties up to $25.000 per violation. . ",,IIn11111,71Ih,1 North Carolina Professional Engineer's seal, signature, and date: ,C A 7 �'•.,� • �' SEAL i 045959 i IV G $P j Applicant's Certification perl5A NCAC 02T .0106(b): 1, Todd Taylor, P.E., Executive Director attest that this application for (SignatureAuthority's name& title from Application Item 1.3.) has been reviewed by me and is accurate and complete to the best of my knnwledge.1 understand that Wall required parts of this application are not completed and that Wall required supporting documentation and attachments are not included. this application package is subject to being returned as incomplete. i understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate cniorcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. 1 also understand that it -all required parts of this application package are not completed and that it'all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE -- In accordance vvith General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any' false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $f 0,000 as well as civil penalties up to $25.000 per violation. sigRtu Date: 7/10/2020 FORM: FTA 04-16 Page 5 of 3 '000 L = " L dVVI 319NVjavno 71H -13dVHO L. Cf: LL1 47 MIS 103 SGOOM 'IC 8F- .V"o J S