HomeMy WebLinkAbout20190752 Ver 4_SAW-2019-00206 NWP 38 Old Outfall 002_20200813U.S. ARMY CORPS OF ENGINEERS
WILMINGTON DISTRICT
Action Id. SAW-2019-00206 County: Bladen U.S.G.S. Quad: NC-Duart
GENERAL PERNHT (REGIONAL AND NATIONWIDE) VERIFICATION
Permittee: The Chemours Company-Favetteville Works
Attn.: Christel Compton
Address: 22828 NC Highwav 87 W
Fayetteville, NC 28306
Telephone Number: (910) 678-1213
Size (acres) 2150
Nearest Waterway Georgia Branch
USGS HUC 03030005
Nearest Town Fayetteville
River Basin Cape Fear
Coordinates Latitude:34.84677
Longitude:78.82648
Location description: The project area is located at the Chemours property at 22828 NC Highway 87 W in Fayetteville, Bladen
County, North Carolina.
Description of projects area and activity: This verification authorizes Chemours to construct a water treatment
facility and an instream structure in the Old Outfall 002 stream of width of 12 feet and 270'. The
instream structure would create a small impoundment, and the water in this impoundment would be
pumped to the new treatment facility and eventually discharged back into the Cape Fear River. The
instream structure would include a small weir that is armored with rip -rap upstream and
downstream of the weir to prevent erosion in the stream channel during stormwater flooding and
during backwater flooding from the Cape Fear River. Discharges below the ordinary high water
mark (OHWM) will primarily be from rip -rap to protect the stream banks and the stream substrate
(upstream and downstream) as water crosses the weir during stormwater events. During
construction, a new haul road/access road will be constructed to the weir, and a water treatment
facility will be constructed in the uplands north of Old Outfall 002 stream. Temporary impacts
would include construction of a temporary coffer dam and a small instream excavation upstream
from the coffer dam to allow bypass pumping during construction of the instream weir.
Applicable Law(s): ® Section 404 (Clean Water Act, 33 USC 1344)
❑ Section 10 (Rivers and Harbors Act, 33 USC 403)
Authorization: Nationwide Permit 38
SEE ATTACHED NWP GENERAL, REGIONAL, AND/OR SPECIAL CONDITIONS
Your work is authorized by the above referenced permit provided it is accomplished in strict accordance with the enclosed
Conditions, your application received in our office on 8/30/2019, and the enclosed plans The Chemour Company. Any violation
of the attached conditions or deviation from your submitted plans may subject the permittee to a stop work order, a restoration
order, a Class I administrative penalty, and/or appropriate legal action.
This verification will remain valid until the expiration date identified below unless the nationwide authorization is modified, suspended
or revoked. If, prior to the expiration date identified below, the nationwide permit authorization is reissued and/or modified, this
verification will remain valid until the expiration date identified below, provided it complies with all requirements of the modified
nationwide permit. If the nationwide permit authorization expires or is suspended, revoked, or is modified, such that the activity would
no longer comply with the terms and conditions of the nationwide permit, activities which have commenced (i.e., are under construction)
or are under contract to commence in reliance upon the nationwide permit, will remain authorized provided the activity is completed
within twelve months of the date of the nationwide permit's expiration, modification or revocation, unless discretionary authority has
been exercised on a case -by -case basis to modify, suspend or revoke the authorization.
Activities subject to Section 404 (as indicated above) may also require an individual Section 401 Water Quality Certification. You
should contact the NC Division of Water Resources (telephone 919-807-6300) to determine Section 401 requirements.
For activities occurring within the twenty coastal counties subject to regulation under the Coastal Area Management Act (LAMA), prior
to beginning work you must contact the N.C. Division of Coastal Management in Wilmington, NC, at (910) 796-7215.
This Department of the Army verification does not relieve the permittee of the responsibility to obtain any other required Federal, State
or local approvals/permits.
If there are any questions regarding this verification, any of the conditions of the Permit, or the Corps of Engineers regulatory program,
please contact Mr. Tom Charles at (910) 251-4101 or thomas.n.charles(&usace.armv.mil.
CHARLES.THOMAS.P.1288547196 Digitally signed by CHARLES.THOMAS.P.1288547196
Corps Regulatory Official: Date: 2019.10.2912:53:57-04'00' Date: 10/29/2019
Expiration Date of Verification: 3 18 2022
Action ID Number: SAW-2019-00206 County: Bladen
Permittee: The Chemours Comfy -Fayetteville Works.
Project Name: The Chemours Company -Fayetteville Works
Date Verification Issued: 10/29/2019
Project Manager: Mr. Tom Charles
Upon completion of the activity authorized by this permit and any mitigation required by the permit,
sign this certification and return it to the following address:
US ARMY CORPS OF ENGINEERS
WILMINGTON DISTRICT
Attn: Mr. Tom Charles
Wilmington Regulatory Office
U.S Army Corps of Engineers
69 Darlington Avenue
Wilmington, North Carolina 28403
or
thomas.p.charles@usace.army.mil
Please note that your permitted activity is subject to a compliance inspection by a U. S. Army Corps of
Engineers representative. Failure to comply with any terms or conditions of this authorization may
result in the Corps suspending, modifying or revoking the authorization and/or issuing a Class I
administrative penalty, or initiating other appropriate legal action.
I hereby certify that the work authorized by the above referenced permit has been completed in
accordance with the terms and condition of the said permit, and required mitigation was completed in
accordance with the permit conditions.
Signature of Permittee
Date
Sensitive / Proprietary
Treiatment
Pl" r
_ Old 002
� r
;' Approximate
Dam 1 Diversion
- �.r •' structure location
CHARLES.THOM Digitally signed by
.� CHARLES.THOMAS.P.1288547196^•�- '��
AS. P.1288547196 Date: 2019.10.2912:54:23-04'00' Appmzimale13— Diverslonsl-1— l—i1.n
is ._,� _ nea�menr Prem
. ! r Dr.ln.q. Network
s• i s
,-4�r- � y r I Plen Bnrder
PARSONS
Old Outfall 002 Capture and Treatment Area
Par— En--n n[s Ir-1ras: —r. Old 0Wall 002 Remedial Options Plan Figure Number 3
Ch° H z82M Fayetteville Works Facility
9
Fayetteville, North Carolina
Project Location Map, Old Outfall 002, Chemours Fayetteville Works
Sensitive / Proprietary
A B C D E F 1 G H
I I
- JL.- -_ _J
� i 1
I I
.� �� I�' iuvounomwr vowu� . �uuc
�` ����r������C�-:� � 3 `,, ��1 •.. k�StT : � !. 'll..� II �'ll IIIt ��l
NOT FOR
CONSTRUCTION
� _ r
1 I i
Digitally signed by
CHARLES.THO CHARLES.THOMAS.P.1288
MAS.P.1288547 547196
Date: 2019.10.2912:54:46-
196-04'00'
j mm
au - I ® iiyy
ua
Iq
�A N. E�PARSON5 ] 5
OA R EI➢ 9369 301 PNINFID F 44
I SYR4L IM E M
,— i t °�_�lil � I f3s)sl-ssea �azazz
CHEfd0UR5
- ryUr Purr
Fors OLD
avrFAu ooz
zzaza Nc-ar
FATEIIEVILLE, NC 2B306
30 ,rR ax cu�IVIL
R Icur�r r CPLAN
6 — u� waw.Tox.n� crw�� 6
'JF n of y1 S�CTo N
oal —A SITE
tt `cool _
As srlowN
C001 A
A B C D E F o G c H
Civil Site Plan, Old Outfall 002, Chemours Fayetteville Works
Sensitive / Proprietary
LEGEND
////j IMPOUNDMENT AREA
EXISTING CONTOURS
ORDINARY HIGH WATER MARK
(OHWM)
STONE RIP RAP
-ML. '_` -ML. WETLANDS
U � ❑HU amu / x
I
❑riU IIH
COMS7RUCnOM S'+AGM AREA
+ r x
INFLUENT EFFLUENT
ra- I 1111
INFLUENT PrPaFE ^�
I
COKM
r
-fE PNlfM( rfj
pTER WOC _ PWP $TATgy
TOP EL. 00,E
C0110FETE NEAR-
r yI M~
lk l
NOTES:
1. IMPOUNDMENT VOLUME: 40.000 CUBIC FEET
Civil Facility Site Plan, Figure No. 1, Old Outfall 002, Chemours Fayetteville Works
CHARLES.THOMAS.P.128854 Digitally signed by
CHARLES.THOMAS.P.1288547196
7196 Date: 2019.10.29 12:55:11-04'00'
Sensitive / Proprietary
100 YR FLOOD ZONE ELEVATION: 67.5
70
EXISTING GRADE
� 60
WATER SURFACE
r MAX WATER 11,000
1 ELEV: 47 A
50
TOP OF DAM: 48
MIN WATER ELEVATION: 45
CHANNEL BOTTOM ELEVATION: 40
.30
SECTION A
SCALE: 1"=10'-a" CD01
I
TER
7
WEIR
CHANNEL BOTTOM ELEVATION: 40
SECTION e
SCALE: 1"=10'-0" COQ�
Civil Control Structure, Figure No. 2, Old Outfall 002, Chemours Fayetteville Works
CHARLES.THOMAS.P.� 2$$547196 Digitally
2019.10.2912: 5A3OMAS.P.1288547196
2 04' o
Sensitive / Proprietary
❑riu _USU
—
II cvftsmucnm aroma gnu
�� ICI r
TEW!;FUW
Vwxf COMER Dw
t d
CHARLES.TH0 Digitally signed by
C H A R L ES.TH OM AS. P.1288
MAS.P.1 288547547196
196 04 00' 019.10.29 12:56:07
Civil Temporary Construction, Figure No. 3, Old Outfall 002, Chemours Fayetteville Works