HomeMy WebLinkAboutNCG060414_Application_20200812 N Cr)(0014 I.
FOR AGENCY USE ONLY
Division of Energy, Mineral and Land Resources Date Received
Year Month Day
Land Quality Section to2o cob IZ
National Pollutant Discharge Elimination System Certificate ofCovera e
NIC1G 0161
Check 4 Amount
NCG060000 %%elm 4100
Permit Assigned to
A. L i' *5
NOTICE OF INTENT
National Pollutant Discharge Elimination System application for coverage under General Permit
NCG060000:
STORMWATER DISCHARGES associated with activities classified as: RECEIVED
SIC (Standard Industrial Classification)20 Food and Kindred Products
SIC 21 Tobacco Products AUG 12 2020
SIC 283 Drugs
SIC 284 Soaps, Detergents, & Cleaning Preparations; Perfumes, Cosmetics, &slow.1�: rnt�G
SIC 422 Public Warehousing and Storage (except 4226)
=_f For questions,please contact the DEMLR Regional Office for your area. See page 4.
Do Not use this NO!for renewals.
(Please print or type)
1) Mailing address of owner/operator(address to which all permit correspondence will be mailed):
Name Amazon.com Services LLC-NA Environmental Department
Street Address Po BOX 80842
City Seattle State WA ZIP Code 95108
Telephone No. 206 2661036 Fax:
2) Location of facility producing discharge:
Facility Name Amazon.com Services LLC-DRT4
Facility Contact Natalie Waid
Facility Address Boylston Hwy(NC-280)
Facility City Mills River State NC ZIP Code 28732
Facility County Henderson
Telephone No. 206 266 1036 Fax:
Email waidnata@amazon.com
3) Physical Location Information:
Please provide a narrative description of how to get to the facility(use street names, state road numbers, and
distance and direction from a roadway intersection). Take exit 40 from 1-26,south onto NC-280 W/New Airport Road.
(A copy of a county map or USGS quad sheet with the facility clearly located must be submitted with this application.)
4) Latitude 35°24'53.2"N Longitude 82°33'02.1"W (deg, min, sec)
5) This NPDES Permit Application applies to which of the following:
✓❑ New or Proposed Facility Date operation is to begin 08 Sept 2020
❑ Existing
Page 1 of 4
SWU-221 Last revised 6/24/14
NCG060000 N.O.1.
6) Standard Industrial Classification:
Provide the 4-digit Standard Industrial Classification code (SIC code)that describes the primary industrial
activity at this facility.
SIC code: 4 2 2 5
7) Activities
a) Provide a brief narrative description of the types of industrial activities and products manufactured
at this facility: Facility serves as a distribution warehouse.
b) Check all activities occurring at this facility:
❑ use or process meats ❑ use or process animal fats/byproducts
8) Discharge points/Receiving waters:
How many discharge points (ditches, pipes, channels, etc.)convey stormwater from the property? seven(7)
What is the name of the body or bodies of water(creek, stream, river, lake, etc.)that the facility stormwater
discharges end up in? French Broad River
Receiving water classification: B
Is this a 303(d)listed stream? Yes Has a TMDL been approved for this watershed? No
If the site stormwater discharges to a separate storm sewer system, name the operator of the separate storm
sewer system (e.g. City of Raleigh municipal storm sewer). N/A
List discharge points (outfalls)that convey discharge from the site (both on-site and off-site) and location
coordinates. Attach additional sheets if necessary, or note that this information is specified on the site plan.
Stormwater Outfall No. 001
Latitude(degrees/minutes/seconds): 35°25'1.72" N
Longitude (degrees/minutes/seconds): 82°32'52.57" W
Stormwater Outfall No. 002
Latitude(degrees/minutes/seconds): 35°25'0.44" N
Longitude (degrees/minutes/seconds): 82°32'49.59" W
Stormwater Outfall No. 003
Latitude(degrees/minutes/seconds): 35°24'59,55" N
Longitude (degrees/minutes/seconds): 82°32'49.28" W
Stormwater Outfall No. 004
Latitude(degrees/minutes/seconds): 35°24'52.69" N
Longitude (degrees/minutes/seconds): 82°32'57.14" W
Stormwater Outfall No. 005
Latitude(degrees/minutes/seconds): 35°24'50.13" N
Longitude (degrees/minutes/seconds): 82°32'58.33" W
Stormwater Outfall No. 006 only
Latitude(degrees/minutes/seconds): 35°24'52.59" N
Longitude (degrees/minutes/seconds): 82°32'59.45" W
Stormwater Outfall No. 007 only
Latitude(degrees/minutes/seconds): 35°24'56.26" N
Longitude (degrees/minutes/seconds): 82°32'57.41" W
Page 2 of 4
SWU-221 Last revised 6/24/14
NCG060000 N.O.I.
9) Does this facility have any other NPDES permits?
▪ No
❑ Yes
If yes, list the permit numbers for all current NPDES permits for this facility: N/A
10) Does this facility have any Non-Discharge permits (ex: recycle permit)?
No
❑ Yes
If yes, list the permit numbers for all current Non-Discharge permits for this facility: N/A
11) Does this facility employ any best management practices for stormwater control?
❑ No
• Yes (Show any structural BMPs on the site diagram.)
If yes, please briefly describe: Indoor storage,covered dumpsters,inspections,housekeeping,training,preventative maintenance.
12) Does this facility have a Stormwater Pollution Prevention Plan?
❑ No
II Yes
If yes, when was it implemented? To be implemented in September2020
13)Are vehicle maintenance activities occurring at this facility?
❑ No I Yes
14) Hazardous Waste:
a) Is this facility a Hazardous Waste Treatment, Storage, or Disposal Facility?
▪ No ❑ Yes
b) Is this facility a Small Quantity Generator(less than 1000 kg. of hazardous waste generated per month)of
hazardous waste?
❑ No NI Yes
c) Is this facility a Large Quantity Generator(1000 kg. or more of hazardous waste generated per month)of
hazardous waste?
▪ No ❑ Yes
d) Is hazardous waste stored in the 100-year flood plain?
I No ❑ Yes If yes, include information to demonstrate protection from flooding.
e) If you answered yes to questions b. or c., please provide the following information:
Type(s)of waste: Source of waste is spilled or broken consumer product packaged for retail sale.Waste classifications vary.Most commonly are flammables and corrosives.
How is material stored: 55 gallon poly drums or 55 gallon steel drums depending on the waste
Where is material stored: A secured hazardous waste storage area on spill containment pallets
How many disposal shipments per year: Varies and is based entirely on the receiving of damaged products
Name of transport/disposal vendor: US Ecology
Vendor address: 101 S.Capitol Blvd,Suite 1000,Boise,Idaho 83702
Page 3 of 4
SWU-221 Last revised 6/24/14
NCG060000 N.O.I.
15)Certification:
North Carolina General Statute 143-215.6B(i) provides that:
Any person who knowingly makes any false statement, representation, or certification in any application, record, report,
plan, or other document filed or required to be maintained under this Article or a rule implementing this Article; or who
knowingly makes a false statement of a material fact in a rulemaking proceeding or contested case under this Article;or
who falsifies,tampers with,or knowingly renders inaccurate any recording or monitoring device or method required to be
operated or maintained under this Article or rules of the Commission implementing this Article shall be guilty of a Class 2
misdemeanor which may include a fine not to exceed ten thousand dollars($10,000).
I hereby request coverage under the referenced General Permit. I understand that coverage under this permit
will constitute the permit requirements for the discharge(s) and is enforceable in the same manner as an
individual permit.
I certify that I am familiar with the information contained in this application and that to the best of my
knowledge and belief such information is true, complete, and accurate.
Printed Name of Person Signing: Kevin Winston
Title: Global Field Environmental Leader
9<sevtpL,
` j ► g' Ii/ D
(Signature of Applicant) ( ate Signed)
This Notice of Intent must be accompanied by a check or money order for$100.00, made payable
to: NCDEQ. Do not send the check or money order separately.
Page 4 of 4
SWU-221 Last revised 6/24/14
NCG060000 N.O.I.
Final Checklist
This application will be returned as incomplete unless all of the following items have been included:
Cl Check for$100 made payable to NCDEQ. Must be included with this application (not sent separately).
❑ This completed application and all supporting documents.
❑ A site diagram showing,at a minimum, (existing or proposed):
(a) outline of drainage areas, (b)stormwater management structures, (c) location of stormwater outfalls
corresponding to the drainage areas, (d)runoff conveyance features, (e)areas where materials are stored,
loaded, and unloaded, (f) impervious areas, (g)site property lines.
❑ Copy of county map or USGS quad sheet with the location of the facility clearly marked on the map.
Mail the entire package to:
DEMLR-Stormwater Program
Dept. of Environmental Quality
1612 Mail Service Center
Raleigh, North Carolina 27699-1612
Note
The submission of this document does not guarantee coverage under the General Permit.
For questions,please contact the DEMLR Regional Office for your area.
DEMLR Regional Office Contact Information:
Asheville Office (828)296-4500 -\
Fayetteville Office ... (910)433-3300lit
Mooresville Office ... (704)663-1699
Raleigh Office (919) 791-4200 c • 41,4
Washington Office ...(252)946-6481 ^,. ; ;
Wilmington Office (910) 796-7215 �� -
Winston-Salem (336)771-5000 F. otitis
is ::-- "J
Central Office (919)807-6300
- '�gron
Page 5 of 4
SWU-221 Last revised 6/24/14
DRT4
0
Ohk:
Legend
.q
�rr�Site Boundary
ea
1`t a II
I.•
1 ,e
♦
E
j i
s i
2 000 4 020
- Feet
Figure 1
General Location Map
Site DRT4
Boylston Hwy and Fanning Fields Rd
Asheville,North Carolina 28759
u� tvwW.<rnl.ru
_ m eRnt
LL sou+ce:Esrl•Wald Topogiephk Map WebserNce.WG51984 Web tlercata Aatary Sphe+e
s� `' A
r i i5 ldT, DRT4
-:jam f
4 ' t" ate.
> \ Outfall001 P ,
� Legend
Drainage Area 2 , I5---
Drain
I
a
Shipgag Docks Area
Drainage Area 7 ,ii Quality Device
idpiti
� e Flow Direction
�> _ • JA m
� �, Underground n a Ae Detention Basin
Piping
c)tMaM lb3
i - c ..___ //
y Building
�# Impervious Area
�4 ,`2' Fueling Area
QQ-G�� /./4. „ mMobileMaintenanceArea
``rt� O C55:7 - QMobile Washing Area
_
F. \, - , �ti Jam\ \gi
*i@ iSite Boundary
A2112:3
it- ,;;-Trailer F-.,^y=z_a -e �,,,,., .° Note:
,.. - Site Area:33.7 acres
z Impervious Area:17.8 acres
vi
'N . w ' , Outfa11006 'i ' e:, '; // A
,........, :..,.._ .
jnS Area a ■ _ ti-
T 0.
ri A.- .,, 04 Figure 2
OeAtiNO(fb 4 1Apt Drainage Area Site Map
®>' .. x Site DRT4
Boylston H and Fanning
r�� ;n Ashevwydle,North Carolina
Fields 28759Rd
� .$ ` ~ nr nmmm .emnr r+'.I.naRrn
�..�.�