HomeMy WebLinkAboutWQ0041833_Application (FTSE)_20200714State of North Carolina
Department of Environmental Quality
DWR Division of Water Resources
15A NCAC 02T .0300 - FAST TRACK SEWER SYSTEM EXTENSION APPLICATION
Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION
Application Number: kU 041 PJ3 7(to be completed by DWR} V. ��� C C"�"�!
All items must be completed or the application will be returned ` c� ✓/l
1. APPLICANT INFORMATION: //, J%
1. Applicant's name: The City of Oxford (company, municipality, HOA, utility, etc.)
2. Applicant type: []individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility
❑ Federal ❑ State/County ® Municipal ❑ Other
3. Signature authority's name: Amy L. Ratliff,, PE, per 15A NCAC 021' .0[(. 6(b)
Title: City En ig neer
4. Applicant's mailing address: P0. Box_506-Oxford, NC 25765
City: Oxford State: NC Zip: 27565-,
5. Applicant's contact information:
Phone number: (919) 603-1113 Email Address: aratliff@oxfordnc.org
I1. PROJECT INFORMATION:
1. Project name: The Meadows at oxford
2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project
If modification, provide the existing permit number: WQ00 and issued date:
If new construction but part of a master plan, provide the existing permit number: WQ00
3. County where project is located: Granville
4. Approximate Coordinates (Decimal Degrees): Latitude: 36.282947' Longitude:-78.573387'
5. Parcel 1D(if applicable): 1922-0342-3542, 1922-0450-2921, 1922-0330-8817
(or Parcel ID to closest downstream sewer)
Ili. CONSULTANT INFORMATION:
I. Professional Engineer: Christopher A. Lewis, PE
License Number: 041421
Firm: FLM Engineering, Inc
Mailing address: PO Box 91727
City: Raleigh State: NC Zip: 27675-
Phone number: 9{� 802-7146 Email Address: ciewis(@flmen2ineering.com
IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION:
I. Facility Name: City of Oxford Permit Number: NCO025054
Owner Name: The City of Oxford
V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF):
1. Permit Number(s): WQ Uknown Downstream (Receiving) Sewer Size: inch
Systent Wide Collection v to Permit umbe s _Cf ppkl c 1: WQCS OUO �
Owner Name(s):
ramr,
EA
t�
t—
.r
0
0
0
t7
FORM: FTA 04-16 Page l of 5
VI. GENERAL REQUIREMENTS
1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached?
❑ Yes ❑No ®NIA
2. if the Applicant is a Developer of lots to be sold, has a Developer's Uperatiorial Agreement (FORrvl: DEbeen attached?
❑ Yes ❑No ®NIA
3. If the Applicant is a I tome Property O)tiners' Association, has an Operational Agreement (FORM: HDA' been attached?
❑ Yes ❑No ®NIA
4. Origin of wastewater: (check all that apply):
® Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash
❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels
❑ School / preschool I day care ❑ Medical., dental.., veterinary facilities ❑ Swimming Pool /Clubhouse
❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash
❑ Businesses / offices I factories ❑ Nursing Home ❑ Other (Explain in Attachment)
5. Nature of wastewater: 100 % Domestic/Commercial % Commercial
_ % Industrial (See 15A NCAC 02T .0103(20))
4Is there a Pretreatment Program in effect? ❑ Yes ❑ No
6. Has a flow reduction been approved under 15A NCAC 02T .01 14(tl? ❑ Yes ® No
D If yes, provide a copy of flow reduction approval letter
7. Summarize wastewater generated by project:
Establishment Type (see 02T.0114(f))
Daily Design Flow a b
No. of Units
Flow
3 Bed Room Single Family Homes
360 gal/day
182
65,520 GPD
4 Bed Room Single Family Homes
480 gaVday
120
57,600 GPD
gal.'
3 0a
GPD
gall
GPD
gal;
GPD
gall
GPD
Total
123,120 GPD
a See 15A NCAC 02T .01_I.1(b), (d), (e)(1) and (e)(2) for caveats to wastewater design flnw rate% (i.e., minimum flow per
dwelling; proposed unknown non-residential development uses; public access facilities located near high public use
areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals
as defined in G.S. 42A-4).
b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall
be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data.
8. Wastewater generated by project: 123,120 GPD (per 15A NCAC 02T .0114}
➢ Do not include future flows or previously permitted allocations
If permitted flow is zero, indicate why:
❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line
❑ Flow has already been allocated in Permit Number:
❑ Rehabilitation or replacement of existing sewer with no new flow expected
❑ Other (Explain): -
FORM: FTA 04-16 Page 2 of 5
VI1. GRAVITY SEWER DESIGN CRITERIA (If Applicable)-02T.030 & iyIDC (Crayih Scriersl:
1. Summarize gravity sewer to be permitted:
Size (inches)
Length (feet)
Material
8"
16,110'
SDR26 PVC
8"
1,473'
CL350 DIP
➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria
➢ Section III contains information related to minimum slopes for gravity sewer(s)
➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC
VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — f12T .0305 & MDC(Pump Stations; Force hlnin.4:
COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT
1. Pump station number or name: LS-1
2. Approximate Coordinates (Decimal Degrees): Latitude: 36.291841Longitude:-79.58173 V
3. Design flow of the pump station: 0.5436 millions gallons per day (firm capacity)
4. Operational point(s) of the pump(s); 379.58 gallons per minute at 73.82 feet total dynamic head (TDH)
5. Summarize the force main to be permitted (for this Pump Station):
Size (inches)
Length (feet)
Material
8
2,470'
C900 PVC
6. Power reliability in accordance with 1 iA NCAC 02T _03051h)(I}.
® Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(I)(l3):.
➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day
➢ Must be permanent to facility
Or if the pump station has an average daily flow less than 15,000 gallons per day:
❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T
.0305(h)(1)(C)
or
❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(I )(C):
➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement)
and is compatible with the station.
i If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations'
storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be
provided in the case of a multiple station power outage.
FORM: FTA 04-16 Page 3 of 5
IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)):
1. Does the project comply with all separations found in 15A NCAC 02T .0 +0.5t ) �. !g.'
15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewers stems:
❑ Yes ® No
Setback Parameter*
Separation Required
Storm sewers and other utilities not listed below (vertical)
24 inches
Water mains vertical -water over sewer including in benched trenches
18 inches
Water mains (horizontal)
10 feet
Reclaimed water lines vertical - reclaimed over sewer
I8 inches
Reclaimed water lines (horizontal - reclaimed over sewer)
2 feet
"*Any private or public water supply source, including any wells, WS-1 waters of Class I or
Class 11 impounded reservoirs used as a source of drinking water
100 feet
"Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal
high water (or tide elevation) and wetlands see item IX.2)
50 feet
"Any other stream, lake, impoundment, or ground water lowering and surface drainage
ditches
10 feet
Any building foundation
5 feet
Any basement
10 feet
Top slope of embankment or cuts of 2 feet or more vertical height
10 feet
Drainage systems and interceptor drains
5 feet
Any swimming pools
10 feet
Final earth grade vertical
36 inches
D j5 NCAC 02T_034 contains alternatives where separations in 02T.03ij5i 5 cannot be achieved.
z "Stream classifications can be identified using the Division's NC Surface Water (< J;tssifications weboage
If noncompliance with 02 r.030iff) ur t";s�_ see Section X of this application
-W i4fitVuL
wuvi4
2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ❑ Yes ® No ❑ N/A
7 See the Division's draft separation requirements for situations where separation cannot be meet
➢ No variance is required if the alternative design criteria specified is utilized in design and construction
D As built documents should reference the location of areas effected
3. Does the project comply with setbacks found in the river basin rules per I -A NCACO2B.. 0200'. ® Yes ❑ No ❑ NIA
7 This would include Trout Buffered Streams per 15A NCAC.2B.0202
4. Does the project require coveragerauthorization under a 404 Nationwide or ® Yes ❑ No
individual permits or 401 Water Quality Certifications?
➢ Information can be obtained from the 401 & Buffer permi,tina Branch
5. Does project comply with 13A NCAC 03T.0105(c116) (additional permits/certifications)? ® Yes ❑ No
Per 15A NCAC 021'.010? I c1I61, directly related environmental permits or certification applications are being prepared, have
been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and
sedimentation control plans, stormwater management plans, etc.).
6. Does this project include any sewer collection lines that are deemed "high -priority?"
Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer
positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer.
® Yes ❑ No ❑ N/A
> If yes, include an attachment with details for each line, including type (aerial line, size, material, and location).
High priority lines shall be Inspected by the permittee or its representative at least once every six -months and
inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit.
FORM: FTA 04-16 Page 4 of 5
X. CERTIFICATIONS:
1. Does the submitted system comply with ISA NCAC On, the Minimum Design Criteria fir the Pennittin{- of PgMV Sta iog5
and Force Mains latest version). and the GravjU Sewer Nlinimum Design Criteria [latest version as applicable?
® Yes ❑ No
If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents
for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting
documents.
2. Professional Engineer's Certification:
1, fl E is -m oz A. to t„ !t-t$ PE _ attest that this application for
(Professional Engineer's name from Application Item Ili.l_)
has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications,
engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best
of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer
Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track
Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain
portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this
material and have judged it to be consistent with the proposed design.
NOTE - In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false
statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation.
,.......,...... ........... ...A.Vri. t IT FIT.,
North Carolina Professional Engineer's seal, signature, and date:
3. Applicant's Certification per 15A NCAC 02T .0106(b):
L , t- -F - (-, T -i attest that this application for
(Signature Authority's name & title from Application Item 1.3.)
has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of
this application are not completed and that if all required supporting documentation and attachments are not included, this
application package is subject to being returned as incomplete. 1 understand that any discharge of wastewater from this non -
discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties,
injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a
condition of this permit be violated. I also understand that if all required parts of this application package are not completed
and that if all required supporting information and attachments are not included, this application package will be returned to
me as incomplete.
NOTE - In accordance with General Statutes 143-215.6A and 141-315.6B, any person who knowingly makes any false
statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation.
v
Signature: Date: It Y 12 e)
FORM: FTA 04-16 Page 5 of 5
State of North Carolina
Department of Environmental Quality
Division of Water Resources
Flow Tracking/Acceptance for Sewer Extension Applications
(FTSE 04-16)
Entity Requesting Allocation: The City of Oxford
Project Name for which flow is being requested: The Meadows at Oxford
Afore than one FTSE may be required far a single project if the owner of the TF'IVTP is not responsible for all pump
stations along the route of the proposed wastewater flow.
I. Complete this section only if you are the owner of the wastewater treatment plant.
a. WWTP Facility Name: City of Oxford WWTP
b. WWTP Facility Permit #: NCO025054
All flows are in MGD
c. NVWTP facility's permitted flow
3.50
d. Estimated obligated flow not yet tributary to the WWTP
1.37
e. WWTP facility's actual avg. flow
1.16
f. Total flow for this specific request
0.12
g. Total actual and obligated flows to the facility
2.65
h. Percent of permitted flow used
75.7%
I1. Complete this section for each pump station you are responsible for along the route of this
proposed wastewater flow.
List pump stations located between the project connection point and the WWTP:
(A)
Design
Pump
Average Daily
Station
Firm Flow**
(Name or
Capacity, * (Firm / pi),
Number)
MGD MGD
N/A
(B)
(C)
(D)=(B+C) (E)=(A-D)
Obligated,
Approx.
Not Yet
Total Current
Current Avg.
Tributary
Flow Plus
Daily Flow,
Daily Flow,
Obligated Available
MGD
MGD
Flow Capacity***
* The Firm Capacity of any pump station is defined as the maximum pumped flow that
can be achieved with the largest pump taken out of service.
** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking
factor (pi) not less than 2.5.
*** A Planning Assessment Addendum shall be attached for each pump station located
between the project connection point and the WWTP where the Available Capacity is < 0.
Downstream Facility Name (Sewer):
Downstream Permit Number: NC
Page 1 of 6
1; I'Sl 04-16
III. Certification Statement:
I Amy L. Ratliff certify to the best of my knowledge that the addition of
the volume of wastewater to be permitted in this project has been evaluated along the route to the
receiving wastewater treatment facility and that the flow from this project is not anticipated to
cause any capacity related sanitary sewer overflows or overburden any downstream pump station
en route to the receiving treatment plant under normal circumstances, given the implementation
of the planned improvements identified in the planning assessment where applicable. This
analysis has been performed in accordance with local established policies and procedures using
the best available data. This certification applies to those items listed above in Sections I and II
plus all attached planning assessment addendums for which I am the responsible party.
Signature of this form indicates acceptance of this wastewater flow.
9,
Signing Of
ficial Signature
Dare
u S. O[P.RTMEHT Of THE IHTERIDR lyOXFORD QUADRf.MOL[
u GCO&M-M tur4, #r U$ TopO �krku.u.r.
..n...k..•r r T. llan
Irxry _
- _ I
F.I
� I b
I +i
I I
w ��� .•fry; •w�` -��_ j ,;� - I
�t I k
r g'1JJIF[MO I
t XJ
I
r mk� 1`
• -31 - 4 .. ,� — .� � .X „ '-'A - as ]I n �^ si, orM f
�,nkrwwX.lw UwN kxn WwMxL++-1 fE4E l:li m0 .o. ae.[.r
F'1 fir. • � � " _
�1, ILL •�[ .,y FM1upwi ik
ICI i r { _ . •'-��` �' 414
k �.� s • `�;�+*'fe.* y.} ,
if
FLIENGINEERING
July 10, 2020
Jason Robinson
NCDEQ
Division of Water Resources
1627 Mail Service Center
Raleigh, NC 27699-1636
Reference: The Meadows at Oxford Subdivision
Public Gravity Sewer & Lift Station
Mr. Robinson:
This letter is to accompany the submittal package for the Meadows at Oxford public fast track
sewer extension application form FTA 04-16,
LGI Homes -NC, Inc. is proposing a 302-lot single family subdivision comprising approximately
129.95 acres. The site is located within the City of Oxford on NC Highway 96 on Granville County
Parcel ID Nos. 1922-0342-3542, 1922-0450-2921 & 1922-0330-8817. The project will be
constructed in one phase as shown in the attached construction plans.
The 302-lot development consists of 182 three -bedroom single family homes, and 120 four -
bedroom single family homes. Utilizing the 15A NCAC 02T wastewater design flow rate of 120
gallons per day per bedroom for residential dwellings, the total wastewater flow generated by this
project is expected to be 123,120 gallons per day (GPD).
The gravity sewer system consists of 98 proposed manholes (96 — 4' diameter manholes, 1 — 5'
diameter and 1 — 6' diameter), 16,110 feet of 8-inch SDR26 PVC and 1,473 feet of 8-inch CL350
DIP (public). Additionally, the sewer system proposes an aerial crossing within the public section,
with 40' of 16-inch steel casing pipe_
Additionally, the subdivision development proposes a public sewer lift station that will ultimately
be managed/maintained by the City of Oxford. The lift station consists of a single 8' diameter wet
well, with duplex solid handling pumps, pump control system with telemetry, on site backup
generator, and 2,470' of 8-inch C900 PVC force main. The proposed force main will outlet into an
interceptor manhole just south of the wastewater treatment plant_
Please let me know if you have any questions or need any additional information.
Sincerely,
Christopher A, Lewis, PE
Principal
919.802.7146
clewjs@flmengineering.com
2020 FLM Engineering, Inc,
Page 1 of 1
�}co�mcnta` Q'Javm
Of
NC�ept En
r Rc�t°na, ���lCe
R3�ctg
July 10, 2020
PO Box 91727, Raleigh, NC 27675 p 1919.610.1051