Loading...
HomeMy WebLinkAboutNCG030717_Application_20200811 HIELD ENGINEERING, INC. RECEIVED July 29, 2020 AUG 112020 DEMLR—Stormwater Program Dept. of Environmental QualityDENR-LAND QUALITY NC STORMWATER PERMITTING 1612 Mail Service Center Raleigh, North Carolina 27699-1612 Subj: Notice of Intent for Coverage under NPDES Permit NCG030000; Request for Representative Outfall Status; Request for Change in Monitoring Location Jim Myers and Sons, Inc.—Charlotte, NC Shield Project No. 1200008-03 Dear Program Manager: Shield Engineering, Inc. (Shield), on behalf of Jim Myers and Sons, Inc. (IMS) is submitting the following items: • Notice of Intent for Coverage under NPDES Permit NCG030000 • Request for Representative Outfall Status • Request for Change in Monitoring Location JMS is an existing facility; a Stormwater Pollution Prevention Plan is currently being prepared for the facility and will be developed and implemented in accordance with Part III, Section A, Item 1 of NCG030000. Notice of Intent for Coverage under NPDES Permit NCG030000 Shield has prepared the attached NOI and supporting documentation for JMS which includes a USGS site location map (Figure 1) and a rough draft Facility Map (Figure 2). The NOI requests coverage under NCG030000 for stormwater associated with metal fabricating industrial activities as JMS is classified with SIC code 3589 and discharges stormwater associated with its industrial activity into the Charlotte Mecklenburg MS4. The associated fee for the NOI is also attached. Request for Representative Outfall Status Shield has identified 3 drainage areas at the facility as shown in Figure 2 of the NOI sbumittal. The industrial activities take place in two drainage areas; a third drainage area at the back of the property is not associated with industrial activity. The drainage areas for these two outfalls associated with industrial activity are substantially the same with regards to the types of industrial activity which occur in the area as shown in Figure 2. Shield expects the pollutant characteristics of the stormwater discharge for each of these areas to be similar. Therefore,JMS is requesting Representative Outfall Status for stormwater discharge outfall 002 to allow sampling to occur only at outfall 001. 4301 Taggart Creek Road www.shieldengineering.com Telephone 704.394.6913 Charlotte,NC 28208 Fax 704.394-6913 Notice of Intent for Coverage under NPDES Permit NCG030000; July 29,2020 Request for Representative Outfall Status; Request for Change in Monitoring Location Jim Myers and Sons, Inc.—Charlotte, NC Shield Project No. 1200008-03 Page 2 Request for Change in Monitoring Location Outfall 001 and 002 are located at the property line in a manhole in the center of the only driveway to the facility from Westinghouse. Due to potential safety issues of sampling at the intersection of Westinghouse Boulevard and the main drive during a storm event, JMS is requesting that monitoring occur for Outfall 001 (and representatively for Outfall 002)at the final storm inlet in the drainage area for Outfall 001 (as shown on Figure 2). This inlet combines stormwater from the entire drainage area and will therefore provide a safe, but still representative monitoring location for Outfall 001. Please feel free to contact us should you have any questions or require additional information regarding this NOI, Request for Representative Outfall Status and Request for Change in Monitoring Location. Sincerely, SHIELD Engineering, Inc. { • elind� Gr ene, E.I. Robert L. Griffin, P. . Senior Engineer President/CEO Bra o gg �� Environmental Engineering/EHS Specialist ATTACHMENTS H:\Projects\2020\1200008-03 JMS Environmental Compliance\project details\SPPP\JMS NOI Submittal Letter.docx *SHIELDH 1 , NC&-o D-71-7 FOR AGENCY USE ONLY Division of Energy, Mineral and Land Resources Date Received N -+„ Year Month Day Land Quality Section 2ozv o0 it National Pollutant Discharge Elimination System Certificate ofCoverage N I d 11 ��Check# Amount Environmental NCG030000 4t34S 4'/D0 Quality Permit Assigned to A-.Lidc..s NOTICE OF INTENT National Pollutant Discharge Elimination System application for coverage under General Permit NCG030000: STORMWATER DISCHARGES associated with activities classified as: SIC (Standard Industrial Classification) 335 Rolling, Drawing, and Extruding of Nonferrous Metals SIC 3398 Metal Heat Treating SIC 34 Fabricated Metal Products RECEIVED 35 Industrial and Commercial Machinery 1t SIC 36 Electronic and Other Electrical Equipment AUG 11 SIC 37 Transportation Equipment 2020 SIC 38 Measuring,Analyzing, and Controlling Instruments DENR-LAND QUALITY STORMWATER PERMITTING 1 For questions,please contact the DEMLR Regional Office for your area. See page 4. (Please print or type) 1) Mailing address of owner/operator(address to which all permit correspondence will be mailed): Name Jim Myers&Sons,Inc. Street Address P.O.Box 38778 City Charlotte State NC ZIP Code 28278 Telephone No. 704 554-8397 Fax: 704 554-9113 2) Location of facility producing discharge: Facility Name Jim Myers&Sons,Inc. Facility Contact Derek Fleetwood Street Address 5201 Westinghouse Boulevard City Charlotte State NC ZIP Code 28278 County Mecklenburg Telephone No. 704 554-8397 x1502 Fax: 704 554-9113 Email dfleetwood@jmsequipment.com 3) Physical Location Information: Please provide a narrative description of how to get to the facility(use street names, state road numbers, and distance and direction from a roadway intersection). JMS is located on the west side of Westinghouse Boulevard, south of the Westinghouse/Shopton Road West intersection and north of the Westinghouse/Highway 160 intersection. (A copy of a county map or USGS quad sheet with the facility clearly located must be submitted with this application.) 4) Latitude 3s 08'42"N Longitude 80 59'07"W (deg, min,sec) 5) This NPDES Permit Application applies to which of the following: ❑ New or Proposed Facility Date operation is to begin ❑✓ Existing Page 1 of 4 SWU-218-071408 Last revised 7/2/14 NCG030000 N.O.I. 6) Standard Industrial Classification: Provide the 4-digit Standard Industrial Classification Code(SIC Code)that describes the primary industrial activity at this facility. SIC Code: 3 5 8 9 7) Provide a brief narrative description of the types of industrial activities and products manufactured at this facility: JMS manufacturers stainless steel products for wastewater treatment. The manufacturing processes that occur at the facility include the following types of metal fabrication: grinding,welding,laser cutting,hand passivation,and touch up painting. 8) Discharge points/Receiving waters: How many discharge points (ditches, pipes, channels, etc.) convey stormwater from the property? 2 What is the name of the body or bodies of water(creek, stream, river, lake, etc.)that the facility stormwater discharges end up in? Discharges into Charlotte-Mecklenburg MS4 to Lake Wylie Receiving water classification: ws-Iv Is this a 303(d) listed stream? Yes Has a TMDL been approved for this watershed? Yes If the site stormwater discharges to a separate storm sewer system, name the operator of the separate storm sewer system (e.g. City of Raleigh municipal storm sewer). Charlotte-Mecklenburg MS4 List discharge points (outfalls)that convey discharge from the site(both on-site and off-site) and location coordinates. Attach additional sheets if necessary, or note that this information is specified on the site plan. Stormwater Outfall No. am Latitude (degrees/minutes/seconds): 35ow39• N Longitude(degrees/minutes/seconds): aoswiu W Stormwater Outfall No. 002 Latitude(degrees/minutes/seconds): 3s08'39' N Note: JMS is requesting representative outfall Longitude(degrees/minutes/seconds): 80 59'10" W status for Outfall 002, as the drainage areas for Outfall 001 and 002 contain substantially similar Stormwater Outfall No. industrial activities and the pollutants are expected Latitude (degrees/minutes/seconds): N Longitude(degrees/minutes/seconds): W to be characteristically the same. See attached cover letter for formal request. Stormwater Outfall No. Latitude (degrees/minutes/seconds): N Longitude(degrees/minutes/seconds): W Stormwater Outfall No. Latitude(degrees/minutes/seconds): N Longitude(degrees/minutes/seconds): W Stormwater Outfall No. Latitude(degrees/minutes/seconds): N Longitude(degrees/minutes/seconds): W Stormwater Outfall No. Latitude(degrees/minutes/seconds): N Longitude(degrees/minutes/seconds): W 9) Does this facility have any other NPDES permits? No ❑ Yes If yes, list the permit numbers for all current NPDES permits for this facility: Page 2 of 4 SWU-218-071408 Last revised 7/2/14 NCG030000 N.O.I. 10) Does this facility have any Non-Discharge permits (ex: recycle permit)? I No ❑ Yes If yes, list the permit numbers for all current Non-Discharge permits for this facility: 11) Does this facility employ any best management practices for stormwater control? ❑ No I Yes (Show any structural BMPs on the site diagram.) If yes, please briefly describe: The facility utilizes structural controls such as covers,swales,berms and riprap along with non-structural controls such as preventative mainenance,good housekeeping,and employee training for stormwater control. 12) Does this facility have a Stormwater Pollution Prevention Plan? No Note: A SPPP is currently being prepared for the facility ❑ Yes If yes, when was it implemented? 13)Are vehicle maintenance activities occurring at this facility? • No ❑ Yes 14) Hazardous Waste: a) Is this facility a Hazardous Waste Treatment, Storage, or Disposal Facility? • No ❑ Yes b) Is this facility a Small Quantity Generator(less than 1000 kg. of hazardous waste generated per month)of hazardous waste? ▪ No ❑ Yes c) Is this facility a Large Quantity Generator(1000 kg. or more of hazardous waste generated per month) of hazardous waste? • No ❑ Yes d) Is hazardous waste stored in the 100-year flood plain? I No ❑ Yes If yes, include information to demonstrate protection from flooding. e) If you answered yes to questions b. or c., please provide the following information: Type(s)of waste: How is material stored: Where is material stored: How many disposal shipments per year: Name of transport/disposal vendor: Vendor address: 15)Certification: North Carolina General Statute 143-215.6B (i) provides that: Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan, or other document filed or required to be maintained under this Article or a rule implementing this Article; or who knowingly makes a false statement of a material fact in a rulemaking proceeding or contested case under this Article; or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be Page 3 of 4 SWU-218-071408 Last revised 7/2/14 NCG030000 N.O.I. operated or maintained under this Article or rules of the Commission implementing this Article shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed ten thousand dollars($10,000). I hereby request coverage under the referenced General Permit. I understand that coverage under this permit will constitute the permit requirements for the discharge(s)and is enforceable in the same manner as an individual permit. I certify that I am familiar with the information contained in this application and that to the best of my knowledge and belief such information is true,complete,and accurate. Printed Name of Person Signing: David L.Myers Title: President/CEO 7/5/ `z. (Signature of Applicant) (Dgn d) This Notice of Intent must be accompanied by a check or money order for$100.00,made payable to: NCDEQ Page 4 of 4 SWU-218-071408 Last revised 7/2/14 NCG030000 N.O.I. Final Checklist This application will be returned as incomplete unless all of the following items have been included: Check for$100 made payable to NCDEQ. [a' This completed application and all supporting documents. CV A site diagram showing, at a minimum, (existing or proposed): (a) outline of drainage areas, (b) stormwater management structures, (c) location of stormwater outfalls corresponding to the drainage areas, (d) runoff conveyance features, (e) areas where materials are stored, (f) impervious areas, (g) site property lines. Copy of county map or USGS quad sheet with the location of the facility clearly marked on the map. Mail the entire package to: DEMLR-Stormwater Program Dept. of Environmental Quality 1612 Mail Service Center Raleigh, North Carolina 27699-1612 Note The submission of this document does not guarantee coverage under the General Permit. For questions,please contact the DEMLR Regional Office for your area. DEMLR Regional Office Contact Information: Asheville Office (828) 296-4500 .. Win Solari+ Fayetteville Office (910)433-3300 ski °� al Mooresville Office (704) 663-1699 Raleigh Office (919) 791-4200 lemma_ Ai Washington Office ...(252) 946-6481 n > _ Wilmington Office (910) 796-7215 1 Winston-Salem (336) 771-5000 � '` 'lle . Central Office (919) 807-6300 \-Wit +.:ngton Page 5 of 4 SWU-218-071408 Last revised 7/2/14 • P'' ✓ \tom _ /' Ad(\ -'-K5w00D RD i00—_ 1..(��. r- it's.' ' / � 0.e. /�f\ �' I,� it ?/( 1 it U 1 / t _ i.. �/ Liu / `- P � > �9 r SNOW � L<(kv r �/ i/ I % 77., r I v i 9,,iii;k•y ,; ,1 � 1 • ii _ n. ,, ��% // �Q o\`\,. , (r tt , r.,i / / -T%oo �r="`-, ��� \��j''1 �;.r 1 �.� �i Ili� ," ./ l' 0 1 /� (.. � \/ SHOPTON RD Lily( -S OpL a p -' Q ..klittP.-,,,,- ____,-;*7 viik p� \; Lake f . •1 ?+, �'42 , �� \ \ 1'7 �\\G1 lie , \� i ��1'lit c` jI.,_ „, ,,,, .... , , , Ci �:�. SHIUTTERFLY RD ` .• if �. _ _ 18 l�O@ y3 SA D W 1�BFRfWICK COMM,C�S ' . aA \r. �� '1 v V`\�/� ;..•i ( n ^ \ ,_x ovi 3 , ,,: - -- ,..,„.., • x \ .�,m u pciyOq ' I y -� \ W��AMS GLENN RD j S� a\ .. allAwa _ �� ROCRYSGNL .i Ipp ` e!1 STATE RD 13/3 0/ —� ELEAN op / JL A /jam-- / ORIGBY OR O �� y ` O 650/, 1 1 ---- r ,� CENTERLINE DR' \p`�� // -� �. ,.., ,-_ \ 7. . Illilli-I ' --VP` CEOLTA.IN '�• a \k ( -CLG II_l q`� .\\\) e, I r- li-.%fr.,-- -'. 4 /▪ ' ,`� v. 4 M ASP...... _ �C''' _ OUTFALL 002 t e C�'+� 9 M w, a d PO W 509 lir � mo ouI / \.400 a- l ° I '� l Z ME4py04 .A. -- 4,yT`�y4 -.\ _ ✓ 0 _..__- \ *or ,3 -0.4 KO:I." •O m �; �p 6-7_ N P zRED'H�N (l a ke7-fi r 5� "P 410a t. o 4 C R / \�\ ` apP‘StN�R os�L - OUTFALL 001 �NNTEBELLUM DR 47 .DELSNtRE LN DRt KER D Z O /I 9ry Q / \ Y - _ .j1,l( /— 1 DANNAVEN DR o, K r ,0. trn� t- MERRI WEATHER DR 1 'b i /RECEIVING WATER {Q - \ \ \ lopEOgS 0t ✓ Sf L A ,,9 U - W G - V�, 1 '\ I ? nv t W WESTL �- C S 2/ , // —_y 'w. - *% NC,y0USEBLVO F (� w 3' /te E DR ROY�0R "N 1 `0� t Z p0T0MN.BL ,SERs .-� r \.'l _ , --' I , a p C o _ k c $ \J �/ �► K•TURA,4.,a \ Z i " z \ 650 v IL0 -) 49,, , Z . � SAM'NEELYiR � � \\ ���`^� .,.. w f ' z GRAPHIC SCALE O0 N 0 0.25 0.5 �= Z SHIELD TOat39e�t3ART CREEK ROAD CHARLOTTE,NC 2R208 w I SCALE:1 in.=0.5 MILE. TDa39Cffi88 fax fENGINEERING,INC. ww«'"N°`"0I"°'""0`°'" OUTFACE 001: 35'08'39" N o 80°59'10"W SITE LOCATION MAP I o OUTFACE 002: 35°08 39" N 80°59'10"W JMS ENVIRONMENTAL COMPLIANCE o 5120 WESTINGHOUSE BLVD g RECEIVING WATER:LAKE WYLIE CHARLOTTE,MECKLENBURG,NORTH CAROLINA i- FILE NUMBER 1200008-03 U z SOURCE: NATIONAL GEOGRAPHIC USGS TOPO,7.5 MINUTE MAP DATE: JULY 6, 2020 DRAWN BY: BLH a SERIES,CHARLOTTE WEST, NORTH CAROLINA SCALE: AS SHOWN FIGURE : 01 x „ SHIELD ENGINEERING, INC. RECEIVED July 29, 2020 AUG 112020 DEMLR—Stormwater Program DENR-LAND QUALITY NC Dept. of Environmental Quality STORMWATER PERMITTING 1612 Mail Service Center Raleigh, North Carolina 27699-1612 Subj: Notice of Intent for Coverage under NPDES Permit NCG030000; Request for Representative Outfall Status; Request for Change in Monitoring Location Jim Myers and Sons, Inc.—Charlotte, NC Shield Project No. 1200008-03 Dear Program Manager: Shield Engineering, Inc. (Shield), on behalf of Jim Myers and Sons, Inc. (JMS) is submitting the following items: • Notice of Intent for Coverage under NPDES Permit NCG030000 • Request for Representative Outfall Status • Request for Change in Monitoring Location JMS is an existing facility; a Stormwater Pollution Prevention Plan is currently being prepared for the facility and will be developed and implemented in accordance with Part III, Section A, Item 1 of NCG030000. Notice of Intent for Coverage under NPDES Permit NCG030000 Shield has prepared the attached NOI and supporting documentation for JMS which includes a USGS site location map (Figure 1) and a rough draft Facility Map (Figure 2). The NOI requests coverage under NCG030000 for stormwater associated with metal fabricating industrial activities as JMS is classified with SIC code 3589 and discharges stormwater associated with its industrial activity into the Charlotte Mecklenburg MS4. The associated fee for the NOI is also attached. Request for Representative Outfall Status Shield has identified 3 drainage areas at the facility as shown in Figure 2 of the NOI sbumittal. The industrial activities take place in two drainage areas; a third drainage area at the back of the property is not associated with industrial activity. The drainage areas for these two outfalls associated with industrial activity are substantially the same with regards to the types of industrial activity which occur in the area as shown in Figure 2. Shield expects the pollutant characteristics of the stormwater discharge for each of these areas to be similar. Therefore,JMS is requesting Representative Outfall Status for stormwater discharge outfall 002 to allow sampling to occur only at outfall 001. 4301 Taggart Creek Road www.shieldengineering.com Telephone 704.394.6913 Charlotte,NC 28208 Fax 704.394-6913 Notice of Intent for Coverage under NPDES Permit NCG030000; July 29,2020 Request for Representative Outfall Status; Request for Change in Monitoring Location Jim Myers and Sons, Inc.—Charlotte, NC Shield Project No. 1200008-03 Page 2 Request for Change in Monitoring Location Outfall 001 and 002 are located at the property line in a manhole in the center of the only driveway to the facility from Westinghouse. Due to potential safety issues of sampling at the intersection of Westinghouse Boulevard and the main drive during a storm event, JMS is requesting that monitoring occur for Outfall 001 (and representatively for Outfall 002) at the final storm inlet in the drainage area for Outfall 001 (as shown on Figure 2). This inlet combines stormwater from the entire drainage area and will therefore provide a safe, but still representative monitoring location for Outfall 001. Please feel free to contact us should you have any questions or require additional information regarding this NOI, Request for Representative Outfall Status and Request for Change in Monitoring Location. Sincerely, SHIELD Engineering, Inc. elind � Gr ene, E.I. Robert L. Griffin, P. . Senior Engineer President/CEO Bra Environmental Engineering/EHS Specialist ATTACHMENTS H:1Projects1202011200008-03 JMS Environmental Compliance)project details\SPPP\JMS NOI Submittal Letter.docx -*SHIELD 1 1 • _7 i`7 FOR AGENCY USE ONLY INIZ Division of Energy, Mineral and Land Resources Date Received Year Month Da Land Quality Section If�G':� if National Pollutant Discharge Elimination System Certificate ofCovera:e ©ra k#Amooil A4 pb Check Amount Environmental NCG030000 L*L•i'r-1 0° Quality Permit Assiy ed to A-•Lr NOTICE OF INTENT National Pollutant Discharge Elimination System application for coverage under General Permit NCG030000: STORMWATER DISCHARGES associated with activities classified as: SIC (Standard Industrial Classification) 335 Rolling, Drawing, and Extruding of Nonferrous Metals SIC 3398 Metal Heat Treating SIC 34 Fabricated Metal Products ��^����� SIC 35 Industrial and Commercial Machinery RECEIVED SIC 36 Electronic and Other Electrical Equipment AUG 11 ,2010 SIC 37 Transportation Equipment SIC 38 Measuring, Analyzing, and Controlling Instruments DENR-LAND QUALITY STORMWATER PERMITTING 1 i ,. For questions,please contact the DEMLR Regional Office for your area. See page 4. (Please print or type) 1) Mailing address of owner/operator(address to which all permit correspondence will be mailed): Name Jim Myers&Sons,Inc. Street Address P.O.Box 38778 City Charlotte State NC ZIP Code 28278 Telephone No. 704 554-8397 Fax: 704 554-9113 2) Location of facility producing discharge: Facility Name Jim Myers&Sons,Inc. Facility Contact Derek Fleetwood Street Address 5201 Westinghouse Boulevard City Charlotte State NC ZIP Code 28278 County Mecklenburg Telephone No. 704 554-8397 x1502 Fax: 704 554-9113 Email dfleetwood@jmsequipment.com 3) Physical Location Information: Please provide a narrative description of how to get to the facility(use street names, state road numbers, and distance and direction from a roadway intersection). JMS is located on the west side of Westinghouse Boulevard, south of the Westinghouse/Shopton Road West intersection and north of the Westinghouse/Highway 160 intersection. (A copy of a county map or USGS quad sheet with the facility clearly located must be submitted with this application.) 4) Latitude 35 08'42"N Longitude 80 59'07'W (deg, min, sec) 5) This NPDES Permit Application applies to which of the following: 0 New or Proposed Facility Date operation is to begin p✓ Existing Page 1 of 4 SWU-218-071408 Last revised 7/2/14 NCG030000 N.O.I. 6) Standard Industrial Classification: Provide the 4-digit Standard Industrial Classification Code (SIC Code)that describes the primary industrial activity at this facility. SIC Code: 3 5 8 9 7) Provide a brief narrative description of the types of industrial activities and products manufactured at this facility: JMS manufacturers stainless steel products for wastewater treatment. The manufacturing processes that occur at the facility include the following types of metal fabrication: grinding,welding,laser cutting,hand passivation,and touch up painting. 8) Discharge points/Receiving waters: How many discharge points (ditches, pipes, channels, etc.) convey stormwater from the property? 2 What is the name of the body or bodies of water(creek, stream, river, lake, etc.)that the facility stormwater discharges end up in? Discharges into Charlotte-Mecklenburg MS4 to Lake Wylie Receiving water classification: Ws-Iv Is this a 303(d) listed stream? Yes Has a TMDL been approved for this watershed? Yes If the site stormwater discharges to a separate storm sewer system, name the operator of the separate storm sewer system (e.g. City of Raleigh municipal storm sewer). Charlotte-Mecklenburg MS4 List discharge points (outfalls)that convey discharge from the site(both on-site and off-site) and location coordinates. Attach additional sheets if necessary, or note that this information is specified on the site plan. Stormwater Outfall No. oo, Latitude (degrees/minutes/seconds): 35ar39- N Longitude(degrees/minutes/seconds): 80 se'1a- W Stormwater Outfall No. 002 Latitude (degrees/minutes/seconds): asowas- N Note: JMS is requesting representative outfall Longitude(degrees/minutes/seconds): 80 59'10" W status for Outfall 002, as the drainage areas for Outfall 001 and 002 contain substantially similar Stormwater Outfall No. industrial activities and the pollutants are expected Latitude (degrees/minutes/seconds): N to be characteristically the same. See attached Longitude (degrees/minutes/seconds): W cover letter for formal request. Stormwater Outfall No. Latitude(degrees/minutes/seconds): N Longitude(degrees/minutes/seconds): W Stormwater Outfall No. Latitude (degrees/minutes/seconds): N Longitude(degrees/minutes/seconds): W Stormwater Outfall No. Latitude (degrees/minutes/seconds): N Longitude(degrees/minutes/seconds): W Stormwater Outfall No. Latitude (degrees/minutes/seconds): N Longitude(degrees/minutes/seconds): W 9) Does this facility have any other NPDES permits? I No ❑ Yes If yes, list the permit numbers for all current NPDES permits for this facility: Page 2 of 4 SWU-218-071408 Last revised 7/2/14 NCG030000 N.O.I. 10) Does this facility have any Non-Discharge permits (ex: recycle permit)? II No ❑ Yes If yes, list the permit numbers for all current Non-Discharge permits for this facility: 11) Does this facility employ any best management practices for stormwater control? ❑ No e Yes (Show any structural BMPs on the site diagram.) If yes, please briefly describe: The facility utilizes structural controls such as covers,swales,berms and riprap along with non-structural controls such as preventative mainenance,good housekeeping,and employee training for stormwater control. 12) Does this facility have a Stormwater Pollution Prevention Plan? I No Note: A SPPP is currently being prepared for the facility ❑ Yes If yes, when was it implemented? 13)Are vehicle maintenance activities occurring at this facility? • No ❑ Yes 14) Hazardous Waste: a) Is this facility a Hazardous Waste Treatment, Storage, or Disposal Facility? ▪ No ❑ Yes b) Is this facility a Small Quantity Generator(less than 1000 kg. of hazardous waste generated per month) of hazardous waste? ▪ No ❑ Yes c) Is this facility a Large Quantity Generator(1000 kg. or more of hazardous waste generated per month) of hazardous waste? ▪ No ❑ Yes d) Is hazardous waste stored in the 100-year flood plain? I No ❑ Yes If yes, include information to demonstrate protection from flooding. e) If you answered yes to questions b. or c., please provide the following information: Type(s) of waste: How is material stored: Where is material stored: How many disposal shipments per year: Name of transport/disposal vendor: Vendor address: 15)Certification: North Carolina General Statute 143-215.6B (i) provides that: Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan, or other document filed or required to be maintained under this Article or a rule implementing this Article; or who knowingly makes a false statement of a material fact in a rulemaking proceeding or contested case under this Article;or who falsifies,tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be Page 3 of 4 SWU-218-071408 Last revised 7/2/14 NCG030000 N.O.I. operated or maintained under this Article or rules of the Commission implementing this Article shall be guilty of a Class 2 misdemeanor which may include a fine riot to exceed ten thousand dollars($10,000). I hereby request coverage under the referenced General Permit. I understand that coverage under this permit will constitute the permit requirements for the discharge(s)and is enforceable in the same manner as an individual permit. I certify that I am familiar with the information contained in this application and that to the best of my knowledge and belief such information is true,complete, and accurate. Printed Name of Person Signing: David L.Myers Title: President/CEO 7/3/ 7 (Signature of Applicant) (Dgn d) This Notice of Intent must be accompanied by a check or money order for 5100.00,made payable to: NCDEQ Page 4 of 4 SWU-218-0714D8 Last revised 712/14 NCG030000 N.O.I. Final Checklist This application will be returned as incomplete unless all of the following items have been included: Gd� Check for$100 made payable to NCDEQ. Vr' This completed application and all supporting documents. V A site diagram showing, at a minimum, (existing or proposed): (a) outline of drainage areas, (b) stormwater management structures, (c) location of stormwater outfalls corresponding to the drainage areas, (d) runoff conveyance features, (e) areas where materials are stored, (f) impervious areas, (g) site property lines. Copy of county map or USGS quad sheet with the location of the facility clearly marked on the map. Mail the entire package to: DEMLR-Stormwater Program Dept. of Environmental Quality 1612 Mail Service Center Raleigh, North Carolina 27699-1612 Note The submission of this document does not guarantee coverage under the General Permit. For questions,please contact the DEMLR Regional Office for your area. DEMLR Regional Office Contact Information: Asheville Office (828) 296-4500 sole Fayetteville Office (910)433-3300 I Mooresville Office (704)663-1699 � � �A A Raleigh Office (919)791-4200 - s . A Washington Office ...(252) 946-6481 le �"` �� � Wilmington Office (910) 796-7215 "` Winston-Salem (336) 771-5000 -Kf• lie Central Office (919) 807-6300 ` \ ngton Page 5 of 4 SWU-218-071408 Last revised 7/2/14 '/A V ( 0i, T C( ) 1`Lr\• 1 ° L, " A KswooDnD Ale 06 •r, r,� � �� � } _ , �kti ✓�� E 2 n7 • Ea le T.: �,/r f � ~ i,�. 1 �' ` � 14��. ( � 1 sect r Lake .K lake ' 1\`'X ft' \ --'-(x-:, 2A '14 ,L—? .. 1)) :`s?,-,J 1 .._41,,, ,.. ,,,-, ,,,„ ,,,, „J>,,, -,=-1, c ' ( rn ) \ \ J �' .s v�, - \C - 'III .1 4 ` _.,,'r J -_1,- , FY%91' • = ,,—_,, ',____•._ — 4 N4,' ,,,,-/ " 4 ( ''''',,i'", -''; 1.--' ( ,.4,-:" 1,f-'''' ''' '.-,-"--1` _.— ,t e---)1 (<4:/fi--R.,A.; ;! 1 ' r �� s�ioeiDN RD opt° jp-- i li I i p d ) !� olir it �Saevj. �4)I>_,,,; ��{1 C`` � =cm�� I>\ \ �, , �\.... \Iti, `.._g-� - f``\ !l`� )� Lake V�\vA ���% J i v r ` '',_, vs- i', ^\ ,_ IIe • or ,di �V /,� ^ ,„+ :1 ` 'I t \\ SHIUTTERFLKRD-- �_� 4, I( \ 9\// ��� 'F `�\��.!)411,1/ 1 ` v(\ tit`,' �.� , • ^�_ L Q O 112 $ REIY�CK CP O ('' () o f \ r- _-�7/!' '^`- NA • , 1 \ �`•_; •m u n'10 `*oC,r =1. ,.) j ; 'j `/ W/LUAM NRD .. >� 7'=""iI `.. ' • I .� Roy "�����`�11MIr A ___ I.\\_ r e� 1 ��D� �/S L. / ' 57A7E RD 1)s3 m \�\ ,..� S. �._-,,_ /�i 50: ,, - —j E OR ORO Otti¢i o 1 f ( \��. ,I CENTERLINE OR' QrP�� j �\ /.,_ ‘\ \ Al I d y\-- /VA • _ _�. ,� �/ '_Jake 4. III" 09 - - RRo '� ,'1v W,y GR/FR / lu 1 ��v i 0t i' \�. B -....- f�' C CILIA IN RD 1. /- �\' • y. C\-S 11111111 ����*4;, __�_ - t OUTFALL 002 W _ w w ;, ?�" PQ �� o V 9LVE 1 �o ''T A__ Z 4g rf� Q �a 9P / -y 'W LCK1LNY% 4\ 06 N A , �v.a`ke �ata32 W p `60D Zc1 / 1T� �ti , Da `°mg� OUTFALL 0011.: _Till .7 °a'`�Ea l7 J % ,\ pJ EREL pELSMRE Z o i ,C 3 nn r -, 1 OAKNAVEN DI' �o 1 � MERRIW • Pr^ f RECEIVING WATER "�J / ci;::_ q IJ C] q4, • `• � 0j.r+r '-`-_.� .' '¢ ST/,y0{/pU 9CV t a It E DR. A�0a // _ J` bDw3 CAt \/ �_ ----7) , o j Z 'U7JMN,B �tEji0 t -.: o' ' !?2 \ _ a �.. EK TURN G - \ �'*� a O r\/ _ m A U \ • JTjADR• C SAM'NEELYIFD�\ aL77- 1 4/1,/-- ZJy.-., _ _..ORCHARD - C - W z GRAPHIC SCALE 0 N 0 0.25 0.5 i= 4301 TAGGART CREEK ROAD et 1 SHIELD CHARLOTTE NC 28208 /Oa-39a69t3 w I SCALE:1 in.=0.5 MILE. M4-394433968 fax ENGINEERING, INC • .....v.aee.yineenn;oom i OUTFACE 001: 35°08'39" N o 80`59'10"W SITE LOCATION MAP o !N, o OUTFACE 002: 35°08'39" N JMS ENVIRONMENTAL COMPLIANCE 80` 59'10"W 0 5120 WESTINGHOUSE BLVD g RECEIVING WATER:LAKE WYLIE CHARLOTTE,MECKLENBURG,NORTH CAROLINA N FILE NUMBER 1200008-03 v SOURCE: NATIONAL GEOGRAPHIC USGS TOPO,7.5 MINUTE MAP DATE: JULY 6, 2020 DRAWN BY: BLH a SERIES,CHARLOTTE WEST, NORTH CAROLINA SCALE: AS SHOWN FIGURE : 01 x moo INDUSTRIAL ACTIVITY AREAS LEGEND: ' I N go:4 gr''`.T Z O GARBAGE, WOOD, 8 CARDBOARD WASTE OUTFALL 001 DRAINAGE AREA 80° 059' 10.W c O SW MANHOLE \ Z^$ 1 OUTFALL 002 DRAINAGE AREA 35° 08'39"N - SW PIPING C� O PASSIVATION PROCESS II (REPRESENTED BY OUTFALL �� 001 3 METAL SHAVINGS/SCRAP METAL W �� E Cr �� DRY DETENTION BASIN /� %�-'�'Q Z O TRANSFORMER �� FLOW PATH Z 111Y• 0 O WOOD PALLET/CONTAINER AREA 62.8% IMPERVIOUS AREA-OUTFALL 001 DRAINAGE AREAre , 1 �� i 1-- 1 , • �1j S MN 11- 4. 5' U O PROPANE STORAGE AREA \ // ;/' 1,\\ <? 57.5% IMPERVIOUS AREA OUTFALL 002 DRAINAGE AREA O ' a MATERIAL STORAGE AREA //� - \<< RLl ADDITIONAL LAYDOWN AREA /i ,:� q' t $O LASER TABLE EXHAUST \ /- NON-INDUSTRIAL i` ;� \` s In << GRASSY SWALE � � 9 SHIPPING/RELIEVING • DROP INLET / / \ `< �`' "s O - - • c m • 10 LIQUID NITROGEN / rl ;r �:\ 4 , m O .,. '. _ <�/ __� f �.�� .ram\ \`. `1 .1 I 1 , , _- .\ \ Y'. d d g o w c .7 t.. i L�.-� ,•.�� ' <n tea- ,Th ®} ` • t 1 tt, '',.. 1 1 i , ' f' _--- __ `l`\`�`�\ `1 \� Y2 a k, O.V-. 1,: . / '.., ,4 \\*,,s, x-•••• . . \ „...--.. _ ., o "La, 6E0 Eaz / �• " . 2 t ``',`'` ",`� i' 1, ss ( ' 1 / a, u m o.- N / - ♦ - •i1 I`' , � t 'ti ' ,.'`,;,, ',`I j',,`f 1' ',','' 't t 4.'♦ F-a w▪ n m m d 1 ' I\ \ ' ' -0. a - - Lan. '*,� 4'41• r^ ,/ ,i `, ' f` \ 1 i \'``\ \`\` ,A ~�1 U Q In ( Z % J t' 'S/- _ `'''- `\i`\ \ \_, ' 1 1 i i `' `` ',m. ,.:ran,, 1, Ofti t i I- o �, UNDERGROUND i �' O . 'i >� S SUSPECTED Q y N - ' 1 _--' _ _ _ - i . �- 4. SW BASIN � � =` . / -,*� \' .3'' -----_w - o Z • 1 O j-- i : ' ' `O \, "-"' • ' I \ � m ov ♦ +... , '--- � ` O. p , ------- - - Q \ OUTFACE 001 & 002 rii.1 .' / _ --- \ zs m o a \ - % 22,\::\\\\\::\\:::::-‘ — _ SHEET TITLE: cof , _ PROPOSED OUTFALL 001 \ — ,� _ `' -- NON-INDUSTRIAL _- ,,.- SAMPLING LOCATION \ -- 40 80 \ - FACILITY MAP N <, R 0160 ROUGH DRAFT J \\ ,r' �i 1�� ON FEET) FIGURE North Carolina Secretary of State Search Results Page 1 of 1 • • File an Annual Report/Amend an Annual Report• Upload a PDF Filing • Order.a Document Online••Add Entity to My Email Notification List•View Filings• Print a Pre-Populated Annual Report form • Print an Amended a Annual Report form Business Corporation Legal Name Jim Myers &Sons, Inc. Prey Legal Name Jim Myers and Son, Inc. • Information Sosld: 0100315 Status: Current-Active O Date Formed: 5/26/1966 Citizenship: Domestic Fiscal Month: December Annual Report Due Date: April 15th CurrentAnnual Report Status: Registered Agent: Myers, Dave L. Addresses Mailing Principal Office Reg Office Reg Mailing 5120 Westinghouse Blvd 5120 Westinghouse Blvd 5120 Westinghouse Blvd 5120 Westinghouse Blvd Charlotte, NC 28273 Charlotte, NC 28273 Charlotte, NC 28273 Charlotte, NC 28273 Officers • President David L Myers PO Box 38778 Charlotte NC 28278 Stock Class: COMMON Shares: 10000 • Par Value 10 • • • • https://www.sosnc.gov/online_services/search/Business_Registration_Results 8/11/2020