HomeMy WebLinkAboutWQ0011313_Monitoring - 03-2020_20200519FORM: NDMR 05-16 NON -DISCHARGE MONITORING REPORT (NDMR) Page ( of
Permit No.' WQ0011313
Facility Name: Peppertree Resort WWTP
county: Carteret
Month: March
Year: 2020
PPI: ' 001
Flow Measuring Point: ❑ Influent ❑ Effluent ❑ No flow generated
Parameter Monitoring Point: ❑ Influent ❑' Effluent ❑ Groundwater Lowering ❑ Surface water
Parameter Code
1 50050
00310
00940
50060
31616
00610
00625
00620
00600
00400
00665
70300
00530
00630
00615
i a)
Q E
U H
o
y
1- U
0
;
O
LL
Q
0
m
W
O
L
u
m 0
3 .�
O N O
F O -
of
_ E
}9 �O
, °=
LL O
0
p
E
E
a
-a C
Gf p�
Y 2
s+
o'z
Z
C
l9 LSf
O
('- w
z
a
a.
td
O C
H O
a
N
y 'O
O N O
N N
o
N
N C LS
0 CL O
H. N to
+
N N
}, +.
z Z
w
z
24-hr
hrs
GPD
mg/L
mg/L
mg/L
#/100 mL
mg/L
mg/L
mg/L
mg/L
su
mg/L
mg/L
mg/L
mg/L
mg/L
1
09:30
12,775
2
08:30
1,577
3
7.7
3
06:30
10,000
5
7.7
4
09:00
11,605
5
7.8
5
09:00
15,134
5
7.8
6
09:40
17,183
5
7.7
7
08:15
14,260
8
09:00
5,830
9
09:36
5,830
5
7.7
10
09:49
16,307
5
7.8
11
09:28
19,456
5
7.8
12
09:35
10,580
Q 0
5
<1
052
474
1388
1&62
7.8
2.99
19
13.88
<0.02
13
09:20
6,730
5 ,
7.7
14
15.05
4,985
15
13:50
2,529
16
09:10
1,932
8
7.8
17
09:20
5,653
10
7.7
18
10:05
6,365
10
7.8
19
09:30
8,626
10
7.7
20
09:30
6,289
_10
7.7
21
09:00
7,765
22
12:30
7,765
23
09A0
2,891
10
7.8
24
09:12
5,121
10
7.7
25
09:15
7,452
10
7.7
26
10:48
7,336
5
7.8
27
10:41
3,017
5
7.6
28
13:15
3,379
29
1000
4,373
30
11:00
WASTED
0
5
7.8
31
10:15
3,121
5
7.7
Average:
7,609
0.00
4.87
1.00
0.26
2.37
6.94
9.31
1:50
9.50
6.94
0.00
Daily Maximum:
19,456
2.00
10.00
1.00
0.52
4,74
13.88
18.62
7.80
2.99
19.00
13.88
0.02
Daily Minimum:
0
2.00
3.00
1.00
0.52
4,74
13.88
18.62
7.60
2.99
19.00
13.88
0.02
Sampling Type:
Recorder
Composite
Composite
Grab
Grab
Composite
Composite
Composite
Composite
Grab
Composite
Composite
Composite
Monthly Limit:
80,000
10
14
4
20
Daily Limit:
43
Sample Frequency:
Continuous
See Permit
3 X Year
5 X Week
See Permit
See Permit
See Permit
See Permit
See Permit
5 X Week
See Permit
3 X Year
See Permit
3
FORM: NDMR 05-16 NON -DISCHARGE MONITORING REPORT (NDMR) Page of ,
Sampling Person(s)
Certified Laboratories
Name: Joe Lawrence Name: Environment 1, Inc
Name: Name:
linnc III rrmnnifnrinev elnfn nnrl cmmnlinn frnmrnnrinc mono fhn rnnidrpmnntS in Attachment A of vn11r nPrmit?
nt ❑ Non -Compliant
If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective
action(s) taken. Attach additional sheets if necessary.
Operator in Responsible Charge (ORC) Certification
Permittee Certification
ORC: Robert C. Howard
Permittee: Peppertree Atlantic Beach Owner's Association, Inc.
Certification No.: 996013
Signing Official: Daniel E. Fortin
Grade: WW III Phone mber: 252-393-8720
Signing Officials Title: Operator Responsible in Charge
Has the ORC ch ed since the eviou NDMR? ❑ yes 0 No
Phone Number: 252-393-8720 Permit Expiration: 4/13/2023
G
Y-3o
2
Signature
Date
Signature Date
By this signature, I certify that this report is accurrate and complete to the best of my knowledge.
I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in
accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information
submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for
gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am
aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for
knowing violations.
Mail Original and Two Copies to:
Division of Water Resources
Information Processing Unit
1617 Mail Service Center
Raleigh, North Carolina 27699-1617
FORM: NDAR-2 05-16 NON -DISCHARGE APPLICATION REPORT (NDAR-2) Page J_ of
Permit No.: W00011313
Facility Name: Peppertree Resort WWTP
County: Carteret
Month: March
Year: 2020
Did infiltration occur at
Site Name:
1
Site Name:
2
Site Name;
Site Name:
this facility?
Area (acres):
0.29
Area (acres):
0.29
Area (acres):
Area (acres):
[J' YES nZ NO
Rate (GPD/ft 2
6
Rate (GPD/ft):
6
Rate (GPD/ft 2
Rate (G pDift2):
Weather
Freeboard
Site Infiltrated?
L-1 YES f- N 0
Site Infiltrated?
❑ YES ❑ NO
Site Infiltrated?
1-1 YES NO
Site Infiltrated?
Fi YES ❑ No
0
M
d)
(D
E
0
0
Ix
2
.0
M
W M
0. M
D
Lh !L-
E T
CL
>
d)
0)
E
�7_ �5
t
mi
U_
V
E 2
v
>
4) -
C
0
0 0
LL
5 LD
�z 0.
> -cc
(D
0
C
0
LL
E 2
2 'a
0 Q.
> <
w
E
_
i.-
C
C
0
P
M 0
0
mwN
U.
'F
in
ft
ft
Ual
min
GPD1ft,2
ft
gal
min
GPD/ft'
ft
gal
Mill
GPD/ft'
ft
gal
min
GPD ft2
6,387
6,361
0.51
2
788
__-0,51
0,06
788
0.06
3
5,000
0.40
4
5,802
0.46
5,802
0.46
5
7,567
_7567
0.60
6
8,591
0.68
7
7,130
0_56
7;130
0.56
8
2,915
0.23
2.,915
0.23
9
2,915
0.23
2,915
0.23
10
8,153
0F6
8,153
0.65
11
9,728
0,77
9.728
0.77
12
5,290
0.42
5,290
0.42
13
3,365
0,27
0.27
14
2,,492
0.20
2,492
0.20----
15
1,264
1,264
0.10
16
966
0.08
0.08--__
17
2,826
0,22
_66
__9
4.826
0.22
18
3,182
0.25
3,182
0.25
19
20
3,144
0.25
3,144
0.25
21
3,882
0,31
3,882
0.31
22
3,882
0.31_
31,882
23
1,445
0.11
1,445
0.11
24
2,560
020
2,560
0.20
25
3,726
0.29
3,726
0.29
26
3,668
029
3,668
0.29
27
1,508
0.12
28
1,689
013
1,689
0.13
29
01i
2,186
0.17
30
WAS T
ED
0.00
0
0.00
31
-0
1,560
EIT
1,560
0.12
Monthly Loading (GPD/ft2):'
"6
0.30
#DMO!
#DIV/O!
Year to Date Loadin iGP_61VY
2
52.38
52 8,!8
FORM: NDAR-2 05-16 NON -DISCHARGE APPLICATION REPORT (NDAR-2) Page of
Did the application rates exceed the limits in Attachment B of your permit? Compliant ❑ Non -Compliant ~�
If not a basin, were the sites kept free of vegetation and raked? ompliant ❑ Non -Compliant
If not a basin, were there any instances of effluent ponding in or runoff from the sites? ompliant ❑ Non -Compliant
If a basin, were there any instances of breakout from the berms? [ompliant ❑ Non -Compliant
Was the onsite automatically activated standby power source tested and operational? V&rnphant ❑ Non -Compliant
If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective
action(s) taken. Attach additional sheets if necessary.
Operator in Responsible Charge (ORC) Certification
ORC: Robert C. Howard
Certification No.: 996013
Grade: WW III Phone Number: 252-393-8720
Has the ORC Gbanoed since the prewio(us NDAR-2? [j Yes [] No
,7a -zo
Signature Date
By this signature, I certify that this report is accurrate and complete to the best of my knowledge.
Permittee Certification
Permittee:
Peppertree Atlantic Beach Owner's Association, Inc.
Signing Official: Daniel E. Fortin
Signing Officials Title: Operator Responsible in Charge
Phone Number: 252-393-8720 Permit Exp.: 04/13/2023
{� 6 �e Y -3o -,.2
Signature Date
I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance
with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted. Based on my
inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the
information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant
penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations.
Mail Original and Two Copies to:
Division of Water Resources
Information Processing Unit
1617 Mail Service Center
Raleigh, North Carolina 27699-1617