Loading...
HomeMy WebLinkAboutWM0501402_Application_20190830FOR OFFICE USE ONLY  PERMIT NO.    ISSUED DATE   NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY - DIVISION OF WATER RESOURCES APPLICATION FOR PERMIT TO CONSTRUCT A MONITORING OR RECOVERY WELL SYSTEM PLEASE TYPE OR PRINT CLEARLY In accordance with the provisions of Article 7, Chapter 87, General Statutes of North Carolina and regulations pursuant thereto, application is hereby made for a permit to construct monitoring or recovery wells. 1. Date:July 15, 2020 2.County: Durham 3.What type of well are you applying for? (monitoring or recovery): Monitoring 4.Applicant: Rich Mator, Bristol-Myers Squibb Co. (BMS)Telephone: 609-252-4273 Applicant’s Mailing Address: 3551 Lawrenceville Road, Princeton, NJ 08540 Applicant’s Email Address (if available): Richard.Mator@bms,com 5.Contact Person (if different than Applicant): Jan J Smith (Wood Agent for BMS) Telephone: 919-765-9973 Contact Person’s Mailing Address: 4021 Stirrup Creek Dr., Durham, NC 27703 Contact Person’s Email Address (if available): jan.smith2@woodplc.com 6.Property Owner (if different than Applicant): Nathan Robb, Merritt – IB1, LLC Telephone: Property Owner’s Mailing Address: 2066 Lord Baltimore Drive, Baltimore, MD 21244 Property Owner’s Email Address (if available): 7.Property Physical Address (Including PIN Number) 3252 S. Miami Boulevard, PIN: 0749-40-33-3022.DUR / 0749-03-40-3468 City Durham County Durham Zip Code 27703 8.Reason for Well(s): Replacement of former well M-3-50 to monitor groundwater elevations. To be offset ~ 130’ N/NE. Former M- 3-50 well construction log with lithology is attached. (ex: non-discharge permit requirements, suspected contamination, assessment, groundwater contamination, remediation, etc.) 9. Type of facility or site for which the well(s) is(are) needed: Brownfields, Site I.D. 23016-19-032 (ex: non-discharge facility, waste disposal site, landfill, UST, etc.) 10. Are there any current water quality permits or incidents associated with this facility or site? If so, list permit and/or incident no(s). IHSB ID No: NCD001493931, RCRA Permit NCD 041 463 761 11.Type of contaminants being monitored or recovered: VOCs (ex: organics, nutrients, heavy metals, etc.) 12. Are there any existing wells associated with the proposed well(s)? If yes, how many? part of ~69-well network (Adjacent former Edward Weck, Inc. (Weck) facility - RCRA Permit NCD 041 463 761) Existing Monitoring or Recovery Well Construction Permit No(s).: 47090004 13.Distance from proposed well(s) to nearest known waste or pollution source (in feet): 1,300 14.Are there any water supply wells located less than 500 feet from the proposed well(s)? No If yes, give distance(s): 15.Well Contractor: Richy Lemire w/SAEDACCO Certification No.: NC Drilling License # 2593 Well Contractor Address: 9088 Northfield Drive, Fort Mill, SC 29707 PROPOSED WELL CONSTRUCTION INFORMATION 1. As required by 15A NCAC 02C .0105(f)(7), attach a well construction diagram of each well showing the following: a. Borehole and well diameter e.Type of casing material and thickness b.Estimated well depth f.Grout horizons c.Screen intervals g.Well head completion details d. Sand/gravel pack intervals Continued on Reverse PROPOSED WELL CONSTRUCTION INFORMATION (Continued) 2.Number of wells to be constructed in unconsolidated material: None 3.Number of wells to be constructed in bedrock: One 4. Total Number of wells to be constructed: One (add answers from 2 and 3) 5. How will the well(s) be secured? The well will be secured with lockable, steel, stick-up protective cover 6.Estimated beginning construction date: July 23, 2020 7.Estimated construction completion date: July 24, 2020 ADDITIONAL INFORMATION 1. As required by 15A NCAC 02C .0105(f)(5), attach a scaled map of the site showing the locations of the following: a. All property boundaries, at least one of which is referenced to a minimum of two landmarks such as identified roads, intersections, streams, or lakes within 500 feet of the proposed well or well system. b.All existing wells, identified by type of use, within 500 feet of the proposed well or well system. c. The proposed well or well system. d.Any test borings within 500 feet of proposed well or well system. e. All sources of known or potential groundwater contamination (such as septic tank systems, pesticide, chemical or fuel storage areas, animal feedlots as defined in G.S. 143-215.10B(5), landfills, or other waste disposal areas) within 500 feet of the proposed well or well system. SIGNATURES The Applicant hereby agrees that the proposed well(s) will be constructed in accordance with approved specifications and conditions of this Well Construction Permit as regulated under the Well Construction Standards (Title 15A of the North Carolina Administrative Code, Subchapter 2C) and accepts full responsibility for compliance with these rules Associate Director, Environment Signature of Applicant or *Agent Title of Applicant or *Agent Richard L. Mator *If signing as Agent, attach authorization agreement stating Printed name of Applicant or *Agent that you have the authority to act as the Agent. If the property is owned by someone other than the applicant, the property owner hereby consents to allow the applicant to construct wells as outlined in this Well Construction Permit application and that it shall be the responsibility of the applicant to ensure that the well(s) conform to the Well Construction Standards (Title 15A of the North Carolina Administrative Code, Subchapter 2C). Signature of Property Owner (if different than Applicant) Printed name of Property Owner (if different than Applicant) DIRECTIONS Please send the completed application to the appropriate Division of Water Resources’ Regional Office: Asheville Regional Office 2090 U.S. Highway 70 Swannanoa, NC 28778 Phone: (828) 296-4500 Fax: (828) 299-7043 Fayetteville Regional Office 225 Green Street, Suite 714 Fayetteville, NC 28301-5094 Phone: (910) 433-3300 Fax: (910) 486-0707 Mooresville Regional Office 610 East Center Avenue Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Raleigh Regional Office 3800 Barrett Drive Raleigh, NC 27609 Phone: (919) 791-4200 Fax: (919) 571-4718 Washington Regional Office 943 Washington Square Mall Washington, NC 27889 Phone: (252) 946-6481 Fax: (252) 975-3716 Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, NC 28405 Phone: (910) 796-7215 Fax: (910) 350-2004 Winston-Salem Regional Office 450 W. Hanes Mill Road Suite 300 Winston-Salem, NC 27105 Phone: (336) 776-9800 Fax: (336) 776-9797 GW-22MR Rev. 3-1-2016 Nathan Robb CLIENT REVISIONS PROJECT NO.MPP-18020 FILENAME CHECKED BY DRAWN BY SCALE DATE 06. 28. 2019 N0.DATE 1 09. 11. 2019 RESPONSE TO 1ST SITE PLAN REVIEW X:\Projects\MPP\MPP-18020\Land\Design Files\CGH Working\Wells to Vivki.dwg, 9/17/2019 2:06:32 PM, Harrell, GrayThe John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293 www.mcadamsco.com FLEX BUILDINGS - TW ALEXANDERADMINISTRATIVE SITE PLAN - LEVEL 4DURHAM, NORTH CAROLINA 27703SHEET PLAN INFORMATION MERRITT PROPERTIES 2066 LORD BALTIMORE DRIVE BALTIMORE, MARYLAND 21244 PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION 2066 LORD BALTIMORE DRIVE BALTIMORE, MD 21244 PHONE 410-298-2600 FAX: 410-298-9644 www.MerrittProperties.com EXIS T I N G S M I A M I B L V D S.R. 1 9 5 9 (10 0 ' P U B L I C R / W )EXISTINGT.W. ALEXANDER DRS.R. 2028(VARIABLE WIDTH PUBLIC R/W)C2.00 MPP18020-SITE-OAS1 LAW GH/MG 1"=100' PLAN OVERALL SITE GRAPHIC SCALE 0 50 100 200 1 inch = 100 ft. SITE LEGEND BUILDING BUILDING BUILDING BUILDING 3123 S MIAMI BLVD PIN: 0749-04-50-4965 USE: RES/1-FAMILY ZONING: IL TIER: SUBURBAN 3201 S MIAMI BLVD PIN: 0749-04-50-3758 USE: RES/1-FAMILY ZONING: IL TIER: SUBURBAN 3207 S MIAMI BLVD PIN: 0749-04-50-3655 USE: VAC RES/<10 ACRES ZONING: IL TIER: SUBURBAN 3211 S MIAMI BLVD PIN: 0749-04-50-5259 USE: COM/WHSE-STORAGE ZONING: IL TIER: SUBURBAN 4001 STIRRUP CREEK DRIVE PIN: 0748-02-59-3645 USE: COM/WHSE-STORAGE ZONING: IL TIER: SUBURBAN 3700 S MIAMI BLVD PIN: 0748-38-96-9739 USE: IND/INFO TECH-TELCOMM ZONING: IL TIER: SUBURBAN 3039 E CORNWALLIS RD PIN: 0748-03-27-3425 USE: IND/INFO TECH-TELCOMM ZONING: SRP TIER: SUBURBAN 2910 WECK DR PIN: 0749-03-42-0213 USE: IND/INFO TECH-TELCOMM ZONING: IL TIER: SUBURBAN 2928 WECK DR PIN: 0749-03-41-1792 USE: VACANT INDUSTRIAL ZONING: IL TIER: SUBURBAN 2917 WECK DR PIN: 0749-04-42-7006 USE: VACANT INDUSTRIAL ZONING: IP TIER: SUBURBAN 3020 S MIAMI BLVD PIN: 0749-04-51-3603 USE: COM/OFFICE BLDG ZONING: CN TIER: SUBURBAN EXISTING HILL DRIVE (VARIABLE WIDTH CONTROLLED ACCESS R/W) ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CURRENT CITY OF DURHAM ENGINEERING DESIGN AND CONSTRUCTION STANDARDS SEE SHEET C0.01 FOR ALL PROJECT, SITE, GRADING, STORM DRAINAGE AND UTILITY NOTES GENERAL NOTES: 1.PHASES MAY BE COMBINED OR BUILT IN ANY ORDER. Proposed Relocation of Monitoring Well M-3-50 Figure 1 - Proposed Monitoring Well Network Modifications March 2020 2-Inch Diameter Schedule 40 PVC Riser 6-Inch Diameter Sch. 40 PVC Conductor Casing Expandable Locking Cap Concrete Pad 8 ½-inch Boring for Conductive Casing 4¼-inch Boring for Well Casing No. 2 Filter Sand Pack 0.010-inch Machined Slotted Well Screen 2-Ft.BentoniteSlurry50ft-bgs for Total Well Depth5feet Screen2-Ft. Min.above ScreenSand Pack Neat Cement Grout Neat Cement Grout 20ft-bgs for Conductor Casing 2­ft Stick Up Height PROPOSED WELL CONSTRUCTION DIAGRAM (M-3-50 REPLACEMENT) 3252 S. Miami Boulevard, Durham IHSB ID No: NCD001493931 NOIL III CAR()LINA (XPARIVoLNI Of NAILORAL. NL'SOURCES ANO COMMLMITY DEVELOP►ALNT DIVISION OF ENVIRONMENTAL MANAGEMENT - OROt1NDWATER SECTION P.O. BOX 27887 RALEION.N.0 2r811. PHONE (9191 T,3-5Qa, WELL CONSTRUCTION RECORD M-3-sx DRILLING CONTRACTOR Wilson Well Drilling Co. FOR OFFICE USE ONLY Ouad. No _ Serial No. _ Lat. _ . _ _ Long. —� Pc Minor Basin Basin Cade Headef Ent.. .. GW-1 Ent. DRILLER REGISTRATION NUMBER 1 STATE WELL CONSTRUCTION PERMIT NUMBER: SHWrB Blanket Permit WELL LOCATION: (Show sketch of the location below) Nearest Town. Research Triangle Park County Cornwallis Road and Alexander Drive (Road. Community. or Subdivision and Lot No.) 2. OWNER - IBM Corporation ADDRESS P.O. Box 121.95 RTP . (Street or Route No.) NC 27709 City or Town State Zip Code 3. DATE DRILLED S-7-RR USE OF WELL Monitor 4. TOTAL DEPTH 521 CUTTINGS COLLECTED ❑ Yes EiNo 5. DOES WELL REPLACE EXISTING WELL? ❑ Yes No 6. STATIC WATER LEVEL: FT. ��0}} above TOP OF CASING. below TOP OF CASING IS FT. AMVE LAND SURFACE. 7. YIELD (gpm): METHOD OF TEST 8. WATER ZONES (depth): 9. CHLORINATION: Type . Amount 10. CASING: Durham Depth DRILLING LOG From To Formation Description 0 10 Light Brown Silty CLAY 10 52 Red -Brown to Light Gray Sl,.ghtly Micaceous SILT a,G Boring Terminated at 52 Q --I- in SILT Wall Thickness It additional space is needed use back of form. Depth Diameter or Weight/Ft. Material From To 19 Ft. 611 Steel LOCATION SKETCH (Show direction and distance from at least Iwo State Roads. From To 45 Ft. 1�_ PVC or other map reference points) From To Ft. 11. GROUT: Depth Material Method From To37 Ft. Volclay Pour From To— FI. Bentonite Pour 12. SCREEN: Depth Diameter Slot Size Material From —4-5— To 50 Fl. 2 in. PVC. .010 in. FrJm To F1. in. in. From To Ft. _. in. kX 13. GRAVEL PACK: Depth Sire Material From 42 To 50 Fl. Coarse Sand From 14. REMARKS: -- (over) 1 00 HEREBY CERTIFY IIIA) Ifu:, Wl.11 WAS CONS IRUC IED IN ACCORDANCE WITH IS NCAC 2C. WELL CONSTRUCTIC STANDARDS. AND THAT A GOIPY ()I 11r1`i 111:(' IIAS [W:EN VIDe-D4TO TILE WELL OWNER. T SIGNA 10111: (H C )N I UAC I"I rin Ar-cwd r PROJECT NAME: -::�7B M DATE STARTED: S-- ?- COMPLETED: PAGE OF JOB #:0grg-&pia COUNTY: CITY/TOWN: STATE: BORING/WELL #:M-7 _J TOTAL DEPTH: BORING LOCATION: ELEV.: GEOLOGIST/ENGINEER: Cz.Axa((U MONITORING EQUIPMENT USED: DRILLERS: 0;lSol, DRILLING EQUIPMENT: METHOD: REMARKS: DEPTH TO BOTTOM OF SCREEN: TOP OF SCREEN: SCREEN SLOT SIZE: DEPTH TO BOTTOM OF SAND: TOP OF SAND: DEPTH TO TOP OF BENTONITE: WELL MATERIAL USED: DIAMETER: STICK UP/DOWN: WATER ZONES (DEPTH): STATIC WATER LEVEL: 1 �1 z! S - �� �ay- a0 W �l V' i � REMARKS: et3 S• D r 31 s- q�i•-j. p LITHOLOGY DEPTH SA1TLE NO. BLOW COUNT % REC. SA,%TLE DESCRIPTION AIR QUAL. PPM. '1611 6" M •�o 35 �{ o - yS . L % jInT SILT e s%oW of oil @ Zs P-d -fsv-, -L-. Cis- ctY S►t_ T SAMPLES SUBMITTED FOR LABORATORY TEST 1` I 1. 6 e.43; -' s e-r -to 19 2. 3. 4. a F a