Loading...
HomeMy WebLinkAboutWQ0028842_Sewer Extension_20050512FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3 USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Application Number: (to be completed by DWQ) /'4) QQal, 1. O_1111.1.1wner: 1a. City of Rockingham Full Legal Name (company, municipality, HOA, utility, etc.) Z 1 b. Monty Crump, City Manager O Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials!) Q1 c. The legal entity who will own this system Is. _._ . _ _. ........ ❑ Individual ❑ Federal ® Municipality ❑ State/County ❑ Private Partnership ❑ Corporation ❑ Other 0 1d. 514 Rockingham Road 1e. Rockingham 0 LL Street Address City Z 1f. North Carolina 1g. 28379 Z State Zip Code _0- ~ 1 h. (910) 997-5546 Ili. (910) 997-6617 ;1 j. — monty@gorockingham.com Telephone Facsimile E-mail 2. Project (Facility) Information: cL2a. a Richmond Co. sewer line for Impact Plastics 2b. Richmond County a Brief Project Name (permit will refer to this name) County Where Project is Located R11CHIPvIOND COUNTY CENTURA BAN ROC <INGHANI NC DATE PAY T , ORiDFIR O t t:: r PROVISION FOR PAYMENT OF THIS WARRANT (CR BEEN MADE BY AN APPROPRIATION DULY MADE 0- NOTE DULY AUTHORIZED. AS REQUIRED BY THE _ GOVERNMENT. ACT." iJ H W i CEi4TS'` RICHP41OND COUNTY INTER -FUND X 5a. City of Rockingham 5b. 8" 5c. Owner of Downstream Sewer Receiving Sewer Size Permit Number of Downstream Sewer (if known) 6. The origin of this wastewater is (check all that apply): ❑ Residential Subdivision ❑ Car Wash -! ❑ Apartments/Condominiums ❑ Institution 100 % Domestic/Commercial ❑ Mobile Home Park ❑ Hospital j ❑ School ❑ Church % Industrial ❑ Restaurant ❑ Nursing Home %Other (specify): ® Office ❑ Other (specify): I 7. Volume of wastewater to be permitted in this project: 625 gallons per day 8. If the permitted flow is zero, indicate why: ❑ Interceptor Line - Flow will be permitted is subsequent permits that connect to this line ❑ Flow has already been allocated in Permit No. ❑ Rehabilitation or replacement of existing sewer with no new flow expected FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 1 State of North Carolina Department of Environment and Natural Resources , 0u5 Division of Water Quality FAv-TrvU '.'. FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS (Pressure sewers systems are not to be included as part of this application package) INSTRUCTIONS: Indicate that you have included the following list of required application package items by checking the space provided next to each item. Failure to submit all required items will lead to your application being returned as incomplete or additional processing and review time. This form may be photocopied for use as an original. ® I. Application Form - Submit one original and one copy of the completed and appropriately executed application form. Any changes to this form will result in the application being returned. The Division of Water Quality (Division) will only accept application packages that have been fully completed with all applicable items addressed. You do not need to submit detailed plans and specifications unless you respond NO to Item B(12). ® II. Application Fee - Submit a check in the amount of $400 made payable to: North Carolina Department of Environment and Natural Resources (NCDENR). ❑ III. Certificates of Public Convenience and Necessity — If the application is being submitted in the name of a privately -owned public utility, submit two copies of the Certificate of Public Convenience and Necessity (CPCN) which demonstrates that the public utility is authorized to hold the utility franchise for the area to be served by the sewer extension. If a CPCN has not been issued, provide two copies of a letter from the North Carolina Utilities Commission's Public Staff that states that an application for a franchise has been received, that the service area is contiguous to an existing franchised area, and/or that franchise approval is expected. The project name in the CPCN or letter must match that provided in Item A(2a) of this application. ❑ IV. Operational Agreements — Submit one original and two copies of a properly executed operational agreement if the sewer extension is permitted by a private applicant and will be serving residential or commercial lots (e.g., houses, condominiums, townhomes, outparcels, etc.) that will be sold to another entity. If the applicant is a homeowners' association, use Form HOA 02/03. If the applicant is a developer, use Form DEV 02/03. EVEN IF THE PROJECT WILL BE TURNED OVER TO A MUNICIPALITY, FORM DEV 02/03 IS REQUIRED. ❑ V. Flow Acceptance Letters — If the owner of the downstream sewers and/or WWTF is different from the applicant, submit two copies of a flow acceptance letter from the owner of the downstream sewers and WWTF, if different. Flow acceptance letters must contain the following minimum information: applicant and project name, amount of flow accepted, and name and permit number of the receiving sewers/WWTF. The flow acceptance must not expire prior to permit issuance and must be dated less than a year prior to the application date. Intergovernmental agreements or other contracts will not be accepted in lieu of a project -specific flow acceptance letter. N VI. Map — Submit an 8.5-inch by 11-inch COLOR copy of the portion of a 7.5-minute USGS Topographic Map along with this form. `The map should identify the entire project area location as well as the closest downslope surface waters as clearly as possible. Each map portion must be labeled with the map name and number, the identified location of the sewer line and pump stations, and be of clear and reproducible quality. For instance, if the project involves 4 miles of interceptor sewer that traverses over or near several different waterbodies (or counties, basins, etc.), the map should have location ID's shown for each different waterbody (where the sewer line is within 100 feet of such waterbody - see Instruction VII). This location ID is self chosen and used to cross reference the location in Section C of the permit application. ❑ VII. Stream Classifications — Section C • If any portion of the project is within 100 feet of any down slope surface water, Section C must be completed for the pertinent sections. • If the entire project area is a minimum of 100 feet away from any down slope surface waters BUT there is a pump station involved where a history of power outage is to be used to provide adequate design storage instead of dual feed or permanent or portable generator, Section C must be completed to demonstrate that the closest down slope surface water is Class C (see 15A NCAC 2H .0219(h)(3)(D)). • Use the guidance document entitled, "Determining Watershed Classifications for Form FTA 02/03 (Fast -Track Sewer Systems)" available from http://h2o.enr.state.nc.us/ndpu or by contacting the appropriate regional office. FTA 02/03 - Rev. 1 06/03 FAST —TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 2 ❑ Vill. Environmental Assessments - If this project is subject to an Environmental Assessment (EA) [15A NCAC 01C .0500], this application can not be used. Send the project application on Form PSFMGSA 10/99 to the Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. Applications can not be processed until a Finding of No Significant Impact (FONSI) or Environmental Impact Statement (EIS) has been issued. A copy is to be submitted with that permit application. ❑ IX. Certifications - Section D The application must be certified by both the applicant and a North Carolina Registered Professional Engineer (PE). The applicant signature must match the signing official listed in Item A(1 b). The PE should NOT certify the application if he/she is unfamiliar with 15A NCAC 2H .0200, the Gravity Sewer Minimum Design Criteria (most recent version) and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (most recent version), as applicable to the project. Certification by a PE who is unfamiliar with these documents is subject to NC Board referral. THE COMPLETED FTA 02/03 APPLICATION PACKAGE, INCLUDING ALL SUPPORTING DOCUMENTS AND $400 FEE, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE REGIONAL OFFICE ADDRESS COUNTIES SERVED Asheville Regional Office Avery, Buncombe, Burke, Caldwell, 59 Woodfin Place Cherokee, Clay, Graham, Haywood, Asheville, North Carolina 28801 Henderson, Jackson, Macon, (828) 251-6208 Madison, McDowell, Mitchell, Polk, (828) 251-6452 Fax Rutherford, Swain, Transylvania, Yancey Fayetteville Regional Office 225 Green Street Suite 714 Fayetteville,N Faye Fayetteville, North Carolina 28301 Anson, Bladen, Cumberland, Harnett, 48 Hoke, Montgomery, Moore, Robeson, (910) 486-0707 Fax Richmond, Sampson, Scotland Mooresville Regional Office 919 N Main Street Moor N Mooresville, Mooresville, North Carolina 28115 Alexander, Cabarrus, Catawba, 66 Cleveland, Gaston, Iredell, Lincoln, (704) 663-6040 Fax Mecklenburg, Rowan, Stanly, Union Raleigh Regional Office 1628 Mail Service Center Chatham, Durham, Edgecombe, Raleigh, North Carolina 27699-1628 Franklin, Granville, Halifax, Johnston, (919) 571-47 Lee, Nash, Northampton, Orange, (919) 571-4718 Fax Person, Vance, Wake, Warren, Wilson Washington Regional Office Beaufort, Bertie, Camden, Chowan, 943 Washington Square Mall Craven, Currituck, Dare, Gates, Washington, North Carolina 27889 Greene, Hertford, Hyde, Jones, (252) 946-6481 Lenoir, Martin, Pamlico, Pasquotank, (252) 975-3716 Fax Perquimans, Pitt, Tyrrell, Washington, Wayne Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, North Carolina 28405 Brunswick, Carteret, Columbus, (910) 395-3900 Duplin, New Hanover, Onslow, (910) 350-2004 Fax Pender Winston-Salem Regional Office 585 Waughtown Street Alamance, Alleghany, Ashe, Caswell, Winston-Salem, North Carolina 27107 Davidson, Davie, Forsyth, Guilford, (336) 771-4600 Rockingham, Randolph, Stokes, (336) 771-4631 Fax Surry, Watauga, Wilkes, Yadkin For more information, visit our web site at: http://h2o.enr.state.nc.us/ndpu/ FTA 02/03 - Rev. 1 06/03 FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3 r— USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Application Number: (to be completed by DWQ)/-,f �tth 1. Owner. 1 a. City of Rockingham j Full Legal Name (company, municipality, HOA, utility, etc.) Z 11 b. Monty Crump, City Manager 0 Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials!) Q1 c. The legal entity who will own this system is: ❑ Individual ❑ Federal'Z Municipality ❑ State/County❑ Private Partnership ❑ Corporation ❑ Other (specify): 1d. 514 Rockingham Road le. Rockingham 0 U. Street Address City Z 1f. North Carolina 1g. 28379 Z State Zip Code 1h. (910) 997-5546 1i. (910) 997-6617 1j. monty@gorockingham.com V Telephone Facsimile E-mail 2. Project (Facility) Information: 'J 2a. Richmond Co. sewer line for Impact Plastics 2b. Richmond Count p_ Brief Project Name (permit will refer to this name) County Where Project is Located Q '3. Contact Person: Q 3a. Bryan Bade , Staff Engineer Name and Affiliation of Someone Who Can Answer Questions About this Application '3b. (919) 772-5393 '3c. bbadey@mesco Phone Number E-mail 1. Project is ® New ❑ Modification (of an existing permit) If Modification, Permit No.: For modifications, attach a separate sheet clearly explaining the reason for the modification (i.e. adding another phase, changing line size/length, etc.). Only include the modified information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit. Owner is ® Public (skip to Item B(3)) El Private (go to Item 2(a)) 2a. If private, applicant will be: 2b. If sold, facilities owned by a (must choose on ❑ Retaining Ownership (i.e. store, church, single office, etc.) or ❑ Public Utility (Instruction 111) Z ❑ Leasing units (lots, townhomes, etc. - skip to Item B(3)) ❑ Homeowner Assoc./Developer (Instruction IV) 0 ❑ Selling units (lots, townhomes, etc. - go to Item B(2b)) Q 3. City of Rockingham Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project O4a. Rockingham 4b. NC 0020427 IUL Name of WWTF --- WWTF Permit No. Z 5a. Cityof Rockingham 5b. -- Receiving Sewer Size —---- Permit Number of Downstream Sewer (if known) Owner of Downstream Sewer 6. —�—— — The origin of this wastewater is (check all that apply): W❑ Residential Subdivision El Car Wash IL ❑ Apartments/Condominiums ❑ Institution o 100 /o Domestic/Commercial ❑ Mobile Home Park ❑ Hospital j ❑ School ❑ Church % Industrial ❑ Restaurant ❑ Nursing Home o ® Office El Other (specify): /o Other (specify): 7. Volume of wastewater to be permitted in this project: 625 gallons per day 8. If the permitted flow is zero, indicate why: ❑ Interceptor Line - Flow will be permitted is subsequent permits that connect to this line ❑ Flow has already been allocated in Permit No. ❑ Rehabilitation or replacement of existing sewer with no new flow expected FTA mint - RPv 1 06/01 FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(I) for Item 13(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(1)(1-2) must be approved prior to submittal of this application. Submit a separate request to the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in accordance with 15A NCAC 2H .0219(I)(3). i 25 employees x 25gpd = 625 gallons per day 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) Gravity or Force Main (use the pull down menu) 8" Ductile Iron 135 Gravity W 3 Z Z 0 z' ENTER TOTAL LINE LENGTH IN MILES, 0.03 11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Location ID Power Reliability Option (self chosen - as shown on Design Flow Operational Point (1- dual line feed; 2- permanent generator w/ATS; 3- 0 plans for cross-reference) (MGD) GPM @ TDH portable generator w/telemetry; 4-wet well storage) LL Z N/A N/A N/A N/A F- W_ , C; ii Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force m Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? ® Yes [:]No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested: I I SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13. Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? ❑ Yes ❑ No ® N/A Sedimentation and Erosion Control Plan? ❑ Yes ❑ No ® N/A Stormwater? ❑ Yes ❑ No ® N/A PTA r»mz - Pf-v 1061M FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 5 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality Z regional office (see instructions for addresses) OR indicate the following: ® A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope Qwaterbody; AND, (,� ® A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability U_ option for any pump station near a Class C down slope waterbody. Location ID on Map (self chosen - as shown on Name of Waterbody Stream Waterbody Jmap for cross-reference) Waterbody County River Basin Index Classification Q W U) A 1dw Submit the 8.5" x I I" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! Applicant's Certification: 1, Monty Crump, City Manager, attest that this application for a Sewer Service line to Impact Plastics has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General tutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certifi io in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as 11 a civil en 'e to $25,000 per violation. A Signing Official Signature 1-% Professional Engineer's Certification: Date I attest that this application for a Sewer Service line to Impact Plastics has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143 215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. Jimmy D. Woodie Professional Engineer Name 2b. Municipal Engineering Services Co., P.A. Engineering Firm 2c. P.O. Box 97 Address 2d. Garner City 2e. NC 2f. 27529 State Zip 2g. (919) 772-5393 2h. (919) 772-1176 2i. jwoodie@mesco.com Telephone Facsimile E-mail Seal, Signature & Date FTA 02103 - Rev. 1 06/03 , P - _ <'— a ait - 4� E� Sl: Itt(11` rf 1SFf "� r L t i F�r I�r { SITE s - 1 `n r ,re Al [r �• r� �'! ti' __,. : r t - �,q : -' t �#� 1 1 � bfi I 1 _ l r �i .c. rjs`�� '' �• rl' — — .+ -... •v; ,� ... >: 1, "., i .. ''t. , � i _, If s 1 HAMLET, NC, DATED: 2002 71 j i Transmittal Municipal Engineering Se is Company, P.A. m Garner, N.C. Boone, N.C. LDENIR-Fq Date May 11, 2005 YETTEVLLE REGIONAL OFFlCE Number of pages including cover sheet: TO: NCDENR Division OF Water Quality 225 Green Street, Suite 714 Fayetteville, NC 28301 Phone 910-486-1699 Fax 910-486-0707 FROM: Bryan Badey Municipal Engineering Services Company P.O. 97 Garner,NC 27529 Phone 919 772-5393 Fax (919) 772-1176 IRE: Richmond County Sewer line IREMARKS: ® Urgent ❑ For your review ❑ Reply ASAP ❑ Please Comment Dear Sir or Madam: Please find attached our Fast Track sewer application for approximately 135 feet of 8" gravity sewer under CSX railroad spur line in Richmond County. We have received an approved agreement from CSX, which is included. We have enclosed one original and one copy of the application along with a check for $400.00. If you have any questions regarding this application please call us. Sincerely, Bryan Badey Municipal Engineering Services Company P.A. 05/17/05 1R:07 FAX Ulu Irz 11/6 mui�L�+_�+• _•+„'�'-""' FAX TO: Mr. Mike Lawyer NCDENR Division of Water Quality Atin Phone 910-486-1541 Fax 910-486-0707 RE: CSX Railroad Permit ]Kunieipal U uu W Engineering Saevieae � Coop�vy,P.A. �rcv, N C f Heaaq N.C. Date May 17, 2005 Number of pages including cover sheet 6 _j FROM: Bryan Badey Municipal Engineering Services Company P.O. 97 Garner,NC 27529 Phone 919 772-5393 Fax 919 772-1176. IREMARKS: ® Urgent ❑ For your review 0 Reply ASAP ❑ Please Comment Mr. Lawyer: As per our conversation today, please find attached the permit from CSX railroad for the 8" sewer line extension in Richmond County. If you have any questions do not hesitate to contact me. Sincerely, Bryan Badey Municipal Engineering Services Company P.A. 05/17/05 19:08 FAX 919 772 1176 MUNICIPAL ENGINEERING W & TRANSPORTATION Ken Lisenby specialist Contact ,q dminishmdon a z fl pPR 2 6 2005 D Mr. Rick Sago County Engineer County of Richmond P. 0. Box 504 Rockingham, NC 28379 500 Water Sleet, SC 1190 Jacksomillo, FL 32202.4423 (904) 359-1893 FAX (904) 359.3665 E-Mail: Kcn Lisenby@ct-00m April 20, 2005 Agreement No. CSX-048657 Customer Reference No.: PROJECT #G04095 Re: Installation of pipeline(s) in Dobbins Heights, North Carolina. Dear Mr. Sago: Attached is your fully -executed original of Agreement No. CSX-048657, dated April 4, 2005. No work is to be performed on CSXT property without Roadmaster's authorization. It is your responsibility to schedule any work on CSXT property with CSXT Roadmaster by sending notification via fax, which includes the project description and date and time of work, to fax number: (919) 362-5062, at least thirty (30) days in advance of the date you desire to commence the project. If after one week of faxing notification to CSXT Roadmaster you receive no response, you may call the CSXT Roadmaster at telephone number: (919) 362-9402(ideally between the hours of 6:30 AM and 8:30 AK. If you still have trouble receiving a response from the CSXT Roadmaster, please contact the CSXT Division Engineer's office at telephone number: (843) 664-8210 for assistance. Once work has been scheduled with the Roadmaster, complete and send the attached "FLAGGING REQUEST FORM" to: Property Services - Flagging Project CSX Transportation, Inc. 500 Rater Street, 1180 Jacksonville, FL 32202 Licensee is responsible for paying the actual cost of CSXT flagging and/or support services including all applicable surcharges (collectively "Fees"). 05/17/05 16:08 FAX 919 772 1176 MUNICIPAL ENGINEERING �J v v Y CSX-048657 - 2 - April 20, 2005 Any questions about the form should be directed to 904-359-1387 or 904-359-3404. This agreement, and your right to an encroachment, will expire on. April 3, 2030. L Please make a note of this date. If you require to utilize CSXT property beyond that date, it is your responsibility to contact us, at least 30 days prior to expiration of the agreement. Very truly yours, Ken Lisenby Attachment 05/17/05 16:08 FAX 919 772 1176 MUNICIPAL ENGINEERING LWUU% FORM CSXT 7455 -Rev. i :1-';,/03 Rim APPLICATION FOR -PIPELINE CROSSING OR PARALLELYNG PROPERTIES AND TRACK Submit one original and one copy of both the application and drawing along with a S750.00 nonrefundable Application Fee to CSX Transportation, Property'Services J180, 500 Water Street, Jacksonville, FL 32202, Application and plans must be approved and written authority received from the Railroad before construction is begun. Your proposal and construction must be in accordance with CSXT's - Specifications and any current governing laws or regulations. Note: Specifications fiuttished in the Application Package are to be used as a guideline only. CSXT reserves the right to approve or decline any application- i of L i r.` CL_ s .. If Q C-2� PLEASE SIGN BEFORE COMPLETING: AgreementNo.: I affirm the information I am furnishing in this application will comply with the current CSX Standards, veMing laws or re ns, and accuratel cu the proposed construc etion plans: Si�ature: Application Date: 3 L� ro'ect Owner Information: 3 Check here if agreement should be mailed to this address 1. Complete Legal Name of applicant as it would appear in a legal document (inaccurate information will delay Your reauest): County of Richmond, North Carolina 2. Company Contact Name: Rick Sago, PE Title: County Engineer 3. Telephone: aij 99Z-8234 Fax: 1l9 997-8208 E-Mail: richord coeng@infoave net 4- Street Address: 125 S_ Hancock St.__ City: Rockingham State: NC Zip: 28379 5. Type of business: p 0 Box 504 ❑ Corporation (State of incorporation ) ❑ Partnership (Type and State of partnership ) ❑ Individual ❑ Developer ❑ Municipality 19 Other County Engineer/Consultant Information: I ❑ Check here if agreement should be mailed to this address 6. Company Name: Municipal Engineering Services Co. , PA 7. Company Contact Name: Bryan B a d e v Title: 8. Telephone-(41)).-772-5393 Fax:O_9) 772-1176 EMail.bbadey@mesco.com 9. Street Address: P Q Box 97 City: Garner State: NC_ Zip: 2 7 5 2 9 1140 Benson Hwy., Bldg, 2 ro'ect Information: (Note: Metric Information will NOT be accepted) 10, Is this installation: CkNew ❑ Revision to e-risting ❑ Attachment to existing ❑ Upgrade -_X19 ln9 11. If not a new installation, furnish existing Agreement Number: 12. If this installation is to be a supplement to your master (general) agreement, furnish: Agreement Number Date: 13. Your Reference Number: G (14 0 9 5 14. Work to be performed by: ❑ Applicant's employees Is Applicant an Aegis member? ❑ Yes ❑ No f) Contractor Contractor Name: 15. Town Location: 34owwAymif Dobbins County: Richmond State/Province: NC Heig is (Form continued on Page 2) U0/11/U0 JL rnd aio ... .... C_� X - ()'fxlob ' ( t�UFX U; M 1- /4:)]-.KL'V. 11ru11W (rage 2 or 2) Information 16. Product to be Conveyed: wastewater Flammable: ❑ Yes fXNo Temperature: N I A 17. - Maximum Working Pressure: u / A Field Test Pressure: N / A Type Test: N ( A 18. Location of Shut -Off Valves: N LA 19. Number: IR Manh.oles,_Q__ 0 Other (describe) to be located within Railroad corridor. Manholel shall be flush with -top of ground and dimensions of ancillary structures are requlhed on drawing. 20, Distance .from manholes/other to nearest track: 1Z f per 21. Angle of Crossing: • 68 degrees Number of Tracks to be crossed: 2 22. PIPE SPECH ICATIONS: CARREER PIPE: CASING PIPE: Material Ductile Iron Steel Material Specifications & Grade AWWA C 151 Class 350 AWWA C 2 0 0 Minimum Yield Strength of Material PSI 42,000 35,000 Inside Diameter 8.55 i n . 17.38 in. Wall Thickness 0.25 in. 0.312 in. Outside Diameter 9.05 in.- 18 . 0 0 i n. Type of Seam Seamless Butt -welded or s Kind of Joints Mechanical Joint Butt -welded Total Length Within Railroad R/W 54 feet 54 feet Tunneling (Liner Plates) Note: Attach manuracturer's shoe detail and computations that include plate thickness and Ease. Vents: Number 0 Size Height above ground Seals: ❑ One End ❑ Both Ends Bury depth: Base of rail to top of casing; 12 feet 8 inches Not beneath tracks: 11 feet 0 inches (Below ditches) 10 feet, 0 inches Cathodic Protection: ❑ Yes 1KNo Protective Coating; ❑ Yes (Kind) XXNo 23. Method of installation; D r v Bore & Jack 24. Temporary track support or riprapping required? 0 Yes Q1No (Describe and Detail on Drawing) 25. Wires, poles, obstructions to be relocated? 0 Yes IN No (Describe and Detail on Drawing) 26. Is this both a Crossing and Parallelism? ❑ Yes :9XN0 27. Crossing location: 2 03 6 ' f r;- 2 0 3 7feet North (direction) from Railroad Milepost: 5251 If known: Valuation Station: Valuation Map Number: If known: Latitude/Longitude: If known: Street Address of Crossing/Parallelism: 28. - Parallelism location: Beginning: feet (direction) from RR Milepost: and Ending: feet (direction) from RR Milepost: 29. Total length on Railroad R/W. Length Crossing: Length Paralleling: 30. Will line be eumely within apublic road R/W? 0 Yes 1XNo DOT/AAR Crossing No.- ** If you answered yes, road name, number, and width of public right-of-way are required on drawing 31. a) Will this occupancy connect to an existing facility within Railroad corridor? I Yes ❑ No b) If Yes, name facility owner(s): City of R o e k i n g h am GRailroad Use Only: Division F�-OKEVr .-- Subdivision ��'►' L� 1 � tti1��No. of toss' g9: Absolute. No.: OVR Valuation Section/Map No.: 1%1(MC Lq S"t-ZI-a Valuation Station: a 0 -,r 3 �-, Milepost: S — OAS 0 - 6 1 Roadtnaster No.: N � d,_ Contr. Type: V l S W X — Fiber? ml es 1► 56 L.F. Ir STEEL CASING PIPE W/ 4()O, 78 JG 6 W _y , NI' D.1.P. CLASS 350 CARRB PIPE •INSTALLT BY DRY BOK JACK LD w PRONM INDUSTRIAL SIDETRACK a• PROPOSED 40'01 &ORE PIT U N z - m N N ti 0 wi of oil o. ti ii SANITARY SEATER DUSTING INDUSTRIAL PROPOSED MANHOLE rA N 40s 70, W, CV TO �NlTlay ro°"ilr PROPOSED IC PVC SANITARY SEWER PROPOSED MANHOLE 5 0W DR FORMERLY COUNTY OF RIO ND E)DSTiNC INDUSTRIAL LEAD 1RACK PLAN SCALE: 1" 50 "`+ lir STEEL CA!HIC PIPE �+'� FTNSRED GRADESDE- LEAD g ' D,I,P, CLASS 350 CARRIER PIPE PROPOSED MANHOLE - PRELIMINARY: SECTION A— A NOT FOR CONSlRUC11ON SCALE: 1" _ 2V 4/4/05 4 u 5