HomeMy WebLinkAboutWQ0013398_Monitoring - 03-2020_20200506FORM: NDMR 10-13 NON -DISCHARGE MONITORING REPORT (NDMR) Page of
Permit No.: WQ0013398
Facility Name: Sandpiper Bay WWTF
County: Brunswick
Month: March
Year: 2020
PPI: 001
Flow Measuring Point: ❑ Influent ❑' Effluent ❑ No flow generated
Parameter Monitoring Point: ❑ Influent ❑' Effluent ❑ Groundwater Lowering ❑ Surface Water
Parameter Code -i
50050
00310
00600
00665
50060
31616
00610
00625
00620
00400
00530
00076
o
cc
y
U
O
F y
OG
3
u>
0
m
aci
is pr
H .+
z
`o
R t
O
a
R =
H y=
X0
E
p
LL 0
U
c
0
Q
t y
v_ v�
F d
Yz
v
Z
z
a
'a �'
�o c C
F U) Ui
Y
v
I-
24-hr
hrs
GPD
mg/L
mg/L
m /L
mg/L
#/100 mL
m IL
m /L
m /L
su
mg/L
NTU
1
OT00
4
26,000
0.5
6.9
1
2
07:00
4
26,000
0.5
6.9
1
3
07:00
4
47,000
0.5
6.9
1
4
07,00
4
39,000
3
15
2.87
0.5
<1
1.9
4,7
10.2
6.9
<5.0
1
_
5
07:00
4
42,000
0.5
1 6.9
1
6 1
07:00
4
48,000
0.5
6.9
1
7
07:00
4
45,000
0.5
6.9
1
8
07:00
4
53,000
0.5
6.9
1
9
07:00
4
51,000
0.5
6.9
1
10
07:00
4
48,000
0.5
6.9
1
11
07:00
4
45,000
05
6.9
1
_
12
07:00
4
51,000
0.5
6.9
1
131
07:00
4
56,000
0.5
6.9
1
14
07:00
4
26,000
0.5
6.9
1
15
07:00
4
26,000
0.5
6.9
1
16
07:00
4
47,000
0.5
6.9
1 1
17
OT00
4
39,000
a5
6.9
1
18
07:00
4
48,000
0.5
6.9
1
19
07:00
4
45,000
0.5
6.9
1
20
0700
4
47,000
0.5
6.9
1
21
07:00
4
39,000
0.5
6.9
1
22
0700
4
42,000
0.5
6.9
1
23
07:00
4
1 48,000
0.5
6.9
1 1
24
0700
4
45,000
1
0.5
6.9
1
25
07.00
4
53,000
<2
24
1.5
0.5
<1
<0,2
0,9
1.5
6.9
2.7
1
26
0700
4
51,000
0.5
6.9
1
27
07:00
4
48,000
0.5
6.9
1
28
07:00
4
45,000
1
0.5
6.9
1
291
07:00
1 4
41,000
0.5
1 6 9
1
30
31
Average:
43,690
1,50
8.70
2.19
0.50
1.00
0.95
2.80
5.85
1.35
1,00
Daily Maximum:
56,000
3.00
15.00
2.87
0.50
1.00
1.90
4.70
10.20
6.90
5.00
1.00
_
Daily Minimum:
26,000
2,00
2.40
1.50
0.50
1.00
0.20
0.90
1,50
6.90
2.70
1.00
Sampling Type:
Recorder
Composite
Composite
Composite
Grab
Grab
Composite
Composite
Composite
Grab
Composite
Recorder
Monthly Avg. Limit:
150,000
10
14
4
Daily Limit:
15
25
6
6 to 9
10
10
Sample Frequency:
Continous
2 X Month
2 X Month
2 X Month
5 X week
2 X Month
2 X Month
2 X Month
2 X Month
1 5 X week
2 X Month
Continous
Certified Laboratories
Name: Sunny Wright Name: Environmental Chemist I Wilimington NC
Name: Name:
Does all monitoring data and sampling frequencies meet the requirements in Attachment A of your permit? Compliant _X_ Not Compliant
If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance
and describe the corrective action(s) taken. Attach additional sheets if n
Certification No.: 28813
Grade: II Phone Numbel910-880-4178
Has the ORC changed since the previous NDMR? No
r
gnature Date
By this signature, I certify that this report is accurrate to best of my
knowledge
Signing Official: Timothy Tilma
Signing Official's Title: General Manager
Phone Numker: 910-470-8084,E Permit Exp 5/20/2020
zk / k��
-0A Ozh:�� Ik
Signature Date
I certify, under penalty of law, that this document and all attachments were prepared under my
direction or supervision in accordance with a system designed to assure that all qualified personnel
properly gathered and evaluated the information submitted.
Mail Original and Two Copies to:
Division of Water Resources
Information Processing Unit
1617 Mail Service Center
Raleigh, North Carolina 27699-1617