Loading...
HomeMy WebLinkAboutNC0020486_Inspection_20200714EPA United States Environmental Protection Agency Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 N 52 NC0020486 20/07/14 C S31112171819 20 21 66 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved------------------- N67707172 73 74 75 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) North Mills River Recreation Area 5289 N Mills River Rd Mills River NC 28759 Entry Time/Date Permit Effective Date Exit Time/Date Permit Expiration Date 10:10AM 20/07/14 16/03/01 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Other Facility Data 11:30AM 20/07/14 21/01/31 Name, Address of Responsible Official/Title/Phone and Fax Number James Barry Jones,160 Zillicoa St Asheville NC 28801//828-257-4835/Contacted No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Operations & Maintenance Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date Lauren E Armeni DWR/ARO WQ/828-296-4500/ Daniel J Boss DWR/ARO WQ/828-296-4658/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page#1 DocuSign Envelope ID: F9043CAB-B1E0-452C-8892-0CF722CCBC7B 7/15/2020 7/15/2020 7/15/2020 NPDES yr/mo/day 20/07/14 Inspection Type C3111218 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) On 7/14/2020 I (Daniel Boss) and Lauren Armeni conducted a compliance evaluation inspection of the North Mills River Recreation Area WWTP. We met with Shannon James (ORC) and Juanita James for the inspection. Overall the facility seemed to be operating well and maintained well. The control panel switches for the tertiary filters would not turn on the pumps or blowers, but Juanita demonstrated that the tertiary filter pumps and blowers were still functional by manually switching them on inside the control box. The aeration basin sludge had good settleablity with a clear supernatant. The clarifiers had less than 2 feet of clear water from the surface, but there was no pin floc coming over the weirs. NC0020486 17 (Cont.) Page#2 DocuSign Envelope ID: F9043CAB-B1E0-452C-8892-0CF722CCBC7B Permit:NC0020486 Inspection Date:07/14/2020 Owner - Facility: Inspection Type: North Mills River Recreation Area Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Pump Station - Influent Yes No NA NE Is the pump wet well free of bypass lines or structures? Is the wet well free of excessive grease? Are all pumps present? Are all pumps operable? Are float controls operable? Is SCADA telemetry available and operational? Is audible and visual alarm available and operational? The wet well had a substantial amount of grease and floating solids. Juanita said that the wet well is pumped out once per season. Comment: Bar Screens Yes No NA NE Type of bar screen a.Manual b.Mechanical Are the bars adequately screening debris? Is the screen free of excessive debris? Is disposal of screening in compliance? Is the unit in good condition? Comment: Equalization Basins Yes No NA NE Is the basin aerated? Is the basin free of bypass lines or structures to the natural environment? Is the basin free of excessive grease? Are all pumps present? Are all pumps operable? Are float controls operable? Are audible and visual alarms operable? Page#3 DocuSign Envelope ID: F9043CAB-B1E0-452C-8892-0CF722CCBC7B Permit:NC0020486 Inspection Date:07/14/2020 Owner - Facility: Inspection Type: North Mills River Recreation Area Compliance Evaluation Equalization Basins Yes No NA NE # Is basin size/volume adequate? Comment: Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Diffused Is the basin free of dead spots? Are surface aerators and mixers operational? Are the diffusers operational? Is the foam the proper color for the treatment process? Does the foam cover less than 25% of the basin’s surface? Is the DO level acceptable? Is the DO level acceptable?(1.0 to 3.0 mg/l) The measurements for train 1 were: DO-6.47 mg/L, pH-6.03, settleability- 39%. The measurements for train 2 were: DO-5.55 mg/L, pH-5.40, settleability- 46%. Comment: Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately ¼ of the sidewall depth) The sludge blanket for the train 1 clarifier was 6' out of 9' depth, with 2' of clear water. The sludge blanket for the train 2 clarifier was 7' out of 9' depth, with 1' of clear water. Comment: Filtration (High Rate Tertiary)Yes No NA NE Type of operation:Down flow Is the filter media present? Page#4 DocuSign Envelope ID: F9043CAB-B1E0-452C-8892-0CF722CCBC7B Permit:NC0020486 Inspection Date:07/14/2020 Owner - Facility: Inspection Type: North Mills River Recreation Area Compliance Evaluation Filtration (High Rate Tertiary)Yes No NA NE Is the filter surface free of clogging? Is the filter free of growth? Is the air scour operational? Is the scouring acceptable? Is the clear well free of excessive solids and filter media? All the pumps and blowers were operational, but it was difficult to see into the filters.Comment: Disinfection-Tablet Yes No NA NE Are tablet chlorinators operational? Are the tablets the proper size and type? Number of tubes in use?2 Is the level of chlorine residual acceptable? Is the contact chamber free of growth, or sludge buildup? Is there chlorine residual prior to de-chlorination? Comment: De-chlorination Yes No NA NE Type of system ?Tablet Is the feed ratio proportional to chlorine amount (1 to 1)? Is storage appropriate for cylinders? # Is de-chlorination substance stored away from chlorine containers? Comment: Are the tablets the proper size and type? Are tablet de-chlorinators operational? Number of tubes in use?1 Comment: Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? The right of way was not maintained, but it was accessible.Comment: Page#5 DocuSign Envelope ID: F9043CAB-B1E0-452C-8892-0CF722CCBC7B