HomeMy WebLinkAboutNC0062553_Inspection_20200723EPA United States Environmental Protection Agency Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 N 52 NC0062553 20/07/23 C S31112171819 20 21 66 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved------------------- N67707172 73 74 75 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Wade Hampton Golf Club WWTP NC Hwy 107 Cashiers NC 28717 Entry Time/Date Permit Effective Date Exit Time/Date Permit Expiration Date 11:45AM 20/07/23 17/10/01 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Mark Fredrick Teague/ORC/828-293-9396/ Other Facility Data 12:45PM 20/07/23 22/08/31 Name, Address of Responsible Official/Title/Phone and Fax Number Sandra H Hardy,PO Box 2286 Cashiers NC 28717/Administrator/828-743-9895/Contacted No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Flow Measurement Operations & Maintenance Self-Monitoring Program Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date Lauren E Armeni DWR/ARO WQ/828-296-4500/ Daniel J Boss DWR/ARO WQ/828-296-4658/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page#1 DocuSign Envelope ID: 398AD2C5-78FD-4EB5-BE17-968E40F982DB 7/28/2020 7/28/2020 7/28/2020 NPDES yr/mo/day 20/07/23 Inspection Type C3111218 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) On 7/23/2020 I (Daniel Boss) and Lauren Armeni conducted a compliance evaluation inspection of the Wade Hampton Golf Club WWTP. We requested that the ORC, Gray Wike, not attend the inspection, to reduce the possibility of COVID-19 exposure, since he had been traveling recently. Mark Teague attended the inspection in his place. The composite sampling location was the only violation that I found at the WWTP. The composite samples need to be taken beyond all treatment processes, and the current sampling location precedes chlorination and dechlorination. NC0062553 17 (Cont.) Page#2 DocuSign Envelope ID: 398AD2C5-78FD-4EB5-BE17-968E40F982DB Permit:NC0062553 Inspection Date:07/23/2020 Owner - Facility: Inspection Type: Wade Hampton Golf Club WWTP Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Diffused Is the basin free of dead spots? Are surface aerators and mixers operational? Are the diffusers operational? Is the foam the proper color for the treatment process? Does the foam cover less than 25% of the basin’s surface? Is the DO level acceptable? Is the DO level acceptable?(1.0 to 3.0 mg/l) DO and pH were measured in three places in the aeration basin. The average measured DO was 1.0 mg/L and the average pH was 6.5. Comment: Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately ¼ of the sidewall depth) There was 5' of clear supernatant and 4' of sludge blanket out of 14' of water depth in the clarifier. Comment: Disinfection-Tablet Yes No NA NE Page#3 DocuSign Envelope ID: 398AD2C5-78FD-4EB5-BE17-968E40F982DB Permit:NC0062553 Inspection Date:07/23/2020 Owner - Facility: Inspection Type: Wade Hampton Golf Club WWTP Compliance Evaluation Disinfection-Tablet Yes No NA NE Are tablet chlorinators operational? Are the tablets the proper size and type? Number of tubes in use?4 Is the level of chlorine residual acceptable? Is the contact chamber free of growth, or sludge buildup? Is there chlorine residual prior to de-chlorination? Comment: De-chlorination Yes No NA NE Type of system ?Tablet Is the feed ratio proportional to chlorine amount (1 to 1)? Is storage appropriate for cylinders? # Is de-chlorination substance stored away from chlorine containers? Comment: Are the tablets the proper size and type? Are tablet de-chlorinators operational? Number of tubes in use?3 Comment: Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? The flow meter was last calibrated in May of 2020.Comment: Effluent Sampling Yes No NA NE Is composite sampling flow proportional? Is sample collected below all treatment units? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Page#4 DocuSign Envelope ID: 398AD2C5-78FD-4EB5-BE17-968E40F982DB Permit:NC0062553 Inspection Date:07/23/2020 Owner - Facility: Inspection Type: Wade Hampton Golf Club WWTP Compliance Evaluation Effluent Sampling Yes No NA NE Is the facility sampling performed as required by the permit (frequency, sampling type representative)? Composite effluent samples are being collected before the chlorinator.Comment: Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Comment: Page#5 DocuSign Envelope ID: 398AD2C5-78FD-4EB5-BE17-968E40F982DB