Loading...
HomeMy WebLinkAboutWQ0034203_Sewer Extension_2009070804 WR AT State of North Cai-olina Q91 QG Department of Environment and Natural Resources _ CO r� Division of Water Quality o E` ` FAST -TRACK APPLICATION (FTA 12/07 very) for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS (Pressure R Vacuum sewer systems are not to be included as part of this application package) INSTRUCTIONS: Indicate that you have included/addressed the following list of required application package items by checking the space provided next to each applicable item. Failure to submit all required items will lead to your application being returned as incomplete. Forms are available from the web site or by calling the Regional Office serving your county: http://h2o. enr. state. nc. us/peres/Collection%20Systems/CollectionSystemApplications. html A. Application Form - Submit one original and one copy of the completed and appropriately executed application form. The application should include a project narrative describing the final build -out design (i.e. system and/or pump station to ultimately serve 500 homes, but flow for only 100 homes being requested now). For modifications, clearly explain the reason for the modification (i.e. adding another phase, changing line size/length, etc.). Only include the modified information in this permit application - do not duplicate project information that has already been included in the original permit. Any changes to this form will result in the application being returned. The Division of Water Quality (Division) will only accept application packages that have been fully completed with all applicable items addressed. You do not need to submit detailed plans and specifications unless you respond NO to Item 6(13). Separate applications should be made for non-contiguous sewer systems. B. Application Fee - Submit a check in the amount of $480 made payable to: North Carolina Department of Environment and Natural Resources (NCDENR). Checks shall be dated within 90 days of application submittal. i 0 C. Certificates of Public Convenience and Necessity — If the application is being submitted in the name of a privately -owned public utility, submit two copies of the Certificate of Public Convenience and Necessity (CPCN) which demonstrates that the public utility is authorized to hold the utility franchise for the area to be served by the sewer extension. If a CPCN has not been issued, provide two copies of a letter from the North Carolina Utilities Commission's Public Staff that states that an application for a franchise has been received, that the service area is contiguous to an existing franchised area, and/or that franchise approval is expected. The project name in the CPCN or letter must match that provided in Item A(2)a of this application. LJ D. Operational Agreements — Submit one original and two copies of a properly executed operational agreement, as per 15A NCAC 02T .0115, if the application is submitted by a private applicant and will be serving residential or commercial lots (e.g., houses, condominiums, townhomes, outparcels, etc.) that will be sold to another entity. If the applicant is a home or property owner's association, use Form HOA 02/03. If the applicant is a developer, use Form DEV 02/03. EVEN IF THE PROJECT MAY BE TURNED OVER TO A MUNICIPALITY UPON COMPLETION, FORM DEV 02/03 IS REQUIRED. 0 E. Downstream Sewer, WWTF Capacity and Flow Tracking/Acceptance — FORM FTSE 10/07 (Flow Tracking/Acceptance for Sewer Extension Permit Applications) is required with every application. The applicant (and owners of downstream sewers, pump stations and/or treatment facilities submitting FORM FTSE-10/07) certifies that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving treatment plant, and that the flow from this project will not cause capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving wastewater treatment plant. Where the applicant is not the owner of the downstream sewer, submit two copies of FORM FTSE 10/07 from the owner of the downstream sewer and owner of the WWTF, if different. The flow acceptance indicated in FORM FTSE-10/07 must not expire prior to permit issuance and must be dated less than one year prior to the application date. Submittal of this application and FORM FTSE-10107 Indicates that owner has adequate capacity and will not violate G.S. 143-215.67(a). Intergovernmental agreements or other contracts will not be accepted in lieu of project -specific FTSE 10/07. [j F Map — Submit an 8.5-inch by 11-inch COLOR copy of a USGS Topographic Map of sufficient scale to identify the entire project area and the closest surface waters. Each map or maps must show the location of the sewer line and pump stations and be of reproducible quality. Include a street level map showing the downstream connection point, and the permit number for the downstream sewer, if known. FTA 12/07 [� G. Stream Classifications — Watershed Classification Attachment (Form WSCAS-12/07) If any portion of the sewer system project is within 100 feet of any surface water or wetlands, the Watershed Classification Attachment may -need to be completed. A variance must be requested for encroachment within required setbacks or buffers pursuant to 2T .0305 (f) and be indicated in Item B-13 with supporting documentation/justification provided. [�H Environmental Assessments — If this project Is subject to an Environmental Assessment (EA) [15A NCAC 01C], this application cannot be used. Send the project application on the most current version of Form PSFMGSA to the Design Management Unit, 1633 Mail Service Center, Raleigh, NC 27699-1633. Applications cannot be accepted until a Finding of No Significant Impact (FONSI) or Environmental Impact Statement (EIS) has been issued. A copy is to be submitted with that permit application. Cd I. Flow Direction — Many wastewater treatment systems are entering into agreements for regionalization efforts and emergency treatment capacity. Parts of the system are installed so that the wastewater flow can be directed to more than one treatment facility. If this is the case with this project, please indicate in B(12) and give the permit number of the second treatment facility. [D/J. Certifications — Section C The application must be certified by both the applicant and the design engineer who is a North Carolina Registered Professional Engineer (PE). The applicant signature must match the signing official listed in Item A(1 b). The PE should NOT certify the application if he/she is unfamiliar with 15A NCAC Chapter 2T, the Gravity Sewer Minimum Design Criteria (most recent version) and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (most recent version), as applicable to the project. THE COMPLETED FTA 12107 APPLICATION PACKAGE, INCLUDING ALL SUPPORTING DOCUMENTS AND $480 FEE, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE: REGIONAL OFFICE ADDRESS COUNTIES SERVED Asheville Regional Office 2090 US Highway 70 Avery, Buncombe, Burke, Caldwell, Cherokee, Swannanoa, North Carolina 28778 Clay, Graham, Haywood, Henderson, Jackson, (828) 296-4500 Macon, Madison, McDowell, Mitchell, Polk, (828) 299-7043 Fax Rutherford, Swain, Transylvania, Yancey Fayetteville Regional Office 225 Green Street Suite 714 Anson, Bladen, Cumberland, Harnett, Hoke, Fayetteville, North Carolina 28301-5094 Montgomery, Moore, Robeson, Richmond, (910) 433-3300 Sampson, Scotland (910) 486-0707 Fax Mooresville Regional Office 610 E. Center Avenue Alexander, Cabarrus, Catawba, Cleveland, Mooresville, North Carolina 28115 Gaston, Iredell, Lincoln, Mecklenburg, Rowan, (704) 663-1699 Stanly, Union (704) 663-6040 Fax Raleigh Regional Office 1628 Mail Service Center Chatham, Durham, Edgecombe, Franklin, Raleigh, North Carolina 27699-1628 Granville, Halifax, Johnston, Lee, Nash, (919) 791-4200 Northampton, Orange, Person, Vance, Wake, (919) 788-7159 Fax Warren, Wilson Washington Regional Office 943 Washington Square Mail Beaufort, Bertle, Camden, Chowan, Craven, Washington, North Carolina 27889 Currituck, Dare, Gates, Greene, Hertford, Hyde, (252) 946-6481 Jones, Lenoir, Martin, Pamlico, Pasquotank, (252) 975-3716 Fax Perquimans, Pitt, Tyrrell, Washington, Wayne Wilmington Regional Office 127 Cardinal Drive Extension Brunswick, Carteret, Columbus, Duplin, New Wilmington, North Carolina 28405 Hanover, Onslow, Pander (910) 796-7215 (910) 350-2004 Fax Winston-Salem Regional Office 585 Waughtown Street Alamance, Alleghany, Ashe, Caswell, Davidson, Winston-Salem, North Carolina 27107 Davie, Forsyth, Guilford, Rockingham, Randolph, (336) 771-5000 Stokes, Surry, Watauga, Wilkes, Yadkin (336) 771-4630 Fax For more Information, please visit our web site at: http:/Ih2o.enr.state.nc.uslperes/Collectlon%20Systems/ColiectionSystemsHome.html or contact the Regional Office serving your county. FTA 12/07 USE THE TAB KEY TO MOVE FROM FIELD TO FIELDI Application Number: j�/� (to be completed by DWQ) 4V Q D09-,�p?Q 1. Owner/Permittee: la. Town of Pembroke Full Legal Name (company, municipality, HOA, utility, etc.) 0 1 b. McDuffie Cummings, Town Manager Signing Official Name and Title (Please review 15A NCAC 2T .0106 (b) for authorized signing officials!) 1 c. The legal entity who will own this system is: ❑ Individual ❑ Federal ® Municipality ❑ State/County ❑ Private Partnership ❑ Corporation ❑ Other (specify): 0 1d. 100 S. Union Chapel Road le. Pembroke LL Mailing Address City Z 1f. NC 1g. 28372 Z State Zip Code 0 !1 h. (910) 521-9758 1 i. (910) 521-0472 1 j. mcduffie@pembrokenc.com QTelephone Facsimile E-mail V 2. Prolect (Facility) Information: J 2a. Town of Pembroke Union Chapel Pump Station & Forcemain 2b. Robeson IL Brief Project Name (permit will refer to this name) County Where Project is Located Q 3. Contact Person: Q33a. Edward "Ted" Burke, Cavanaugh & Associates, P.A. Name and Affiliation of Someone Who Can Answer Questions About this Application ,33b. (910) 392-4462 3c. tburke@cavanaughsolutions.com Phone Number E-mail '1. Project is ® New ❑ Modification (of an existing permit) If Modification, Permit No.: 2. Owner is ® Public (skip to Item B(3)) ❑ Private (go to Item 2(a)) 2a. If private, applicant will be: 2b. If sold, facilities owned by a (must choose one) ❑ Retaining Ownership (i.e. store, church, single office, etc.) or ❑ Public Utility (Instruction C) ❑ Leasing units (lots, townhomes, etc. - skip to Item B(3)) ❑ Homeowner Assoc./Developer (Instruction D) ❑ Selling units (lots, townhomes, etc. - go to Item B(2b)) .3. Town of Pembroke Z , Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project 0 4a. Pembroke WWTP 4b. NCO027103 QName of WWTF WWTF Permit No. i5a. Town of Pembroke 15b. 6 inch ® Gravity 15c. WQCS00114 OOwner of Downstream Sewer Receiving Sewer Size El Force Main Permit # of Downstream Sewer (Instruction E) LL 6. The origin of this wastewater is (check all that apply): Z ❑ Residential Subdivision ❑ Retail (Stores, shopping centers) 100 % Domestic/Commercial ❑ Apartments/Condominiums ❑ Institution % Industrial (attach ❑ Mobile Home Park ❑ Hospital description.) ® School ElChurch W El Restaurant El Nursing Home (RO: contact your Regional Office d. ❑ Office ❑ Other (specify): Pretreatment staff) m % Other (specify): 7. Volume of wastewater to be allocated or permitted for this particular project: 9,000 gallons per day *Do not include future flows or previously permitted allocations 8. If the permitted flow is zero, indicate why: ❑ Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit No. ❑ Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T .0303 to determine if a permit is required) FTA12/07 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T .0114 for the value in Item 13(7) AND/OR the design flow for line or pump station sizing if a reduced or zero flow is being requested in Item B(7). Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2T .0114 (f). 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) New Gravity or Additional Force Main 3 19,054 Forcemain Q111. Summary of Pump Stations w/ associated Force Mains to be Permitted (attach additional sheets as necessary) Uj Pump Station Location ID Mission Church Road and St. Anna Road (self chosen - as shown on plans/map for reference) Z _ _ Design Flow Operational Point Power Reliability Option Z (MGD) GPM @TDH 1 -permanent generator w/ATS; Force Main Size Force Main Length O 2 - portable generator w/MTS V , v 0.009 50.5 gpm @ 202' 2 3" 19,054' Z O H iPump Station Location ID (self chosen - as shown on plans/map for reference) Design Flow Operational Point Power Reliability Option (MGD) GPM @TDH 1 - permanent generator w/ATS; Force Main Size Force Main Length Q 2 - portable generator w/MTS LL _ Z H ;Pump Station Location ID (self chosen - as shown on plans/map for reference) W W Design Flow Operational Point Power Reliability Option (MGD) 1 -permanent generator w/ATS; Force Main Size Force Main Length GPM @TDH m 2 - portable generator w/MTS 12. Will the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment facility? ❑ Yes ® No If Yes, permit number of 2nd treatment facility (RO — if "yes" to 13,12 please contact the Central Office PERCS Unit) 13. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 2T as applicable? ® Yes ❑ No If No, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION FTA 12/07 14. Have the following parmllsloertificatlons been submitted for approval for the system or project to be served? Welland/Stream Crossings - General Permit or 401Certification? ❑ Yes ❑ No ® NIA Sedimentation and Erosion Control Plan? ® Yes ❑ No ❑ N/A Stormwater? ® Yes ❑ No ❑ WA 15. Does this project include any high priority lines, (see 15A NCAC 02T .0402 (2)) involve aerial lines, siphons, or interference manholes)? These lines wtil be considered high priority and must be a checked once every six months Check it Yes: [] and provide details 1. OwnerlPermilles's Certification: (Signature of Signing Official and Project Name) 1, WDuffie Cummings. attest that this application for Town of Pembroke Union Chapel Purno Station & Forcemain has been reviewed by me and Is accurate and complete to the best of my knowledge. I understand that N ap required parts o this application are not completed and that if all required supporting documentation and attachments are not included, this application package Is subject to being returned as Incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.68, any person who knowingty makes any false statement, representation, or certification In any application shall be gullly of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well ps civil penalties up toYb 000 per violation. 1a. Signing, f sal Signal re - - - Date ;''" ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS APPLICATION. THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY TO OTHER UTILITIES, DESIGN CALCULATIONS. ETC. REFER TO 15A NCAC 02T .0305 Z 0 Q2. Professional Englneses Certification: (Signature of Design Engineer and Project Name) U 1, , Ted Is y l ke . attest that this application for 1-, A A re'n&-,h has been LL reviewed by me and is accurate, complete and consistent with the information In the eng eering plans, calculations, and all other supporting documentation to the best of my knowledge. ► further attest that to the bast of my knowledge the proposed design has been prepared In accordance with Ilia applicable regulations, Gravity Sewer Minimum Design Cdleda W for Gravity Sewers adopted February f2, 1996, and Ilia Minimum Design Criteria for the Fast -Track Permitting of Pump U Stations and Force Mains adopted June 1, 2000 and the watershed classification In accordance with Division guidance. ANhough other professionals may have developed certain portions ofthis submittal package, inclusion of these materials CS i under my signature and seal signifies that I have reviewed this material and have fudged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingty makes any false statement, representation, or certification in any application shalt be guilty of a Class 2 misdemeanor which may kiclude a nine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. Edward R. Burke P.E. Professional Engineer Name- 2b. Cavanauah & Associates, P.A. _..__ Engineering Firm 2c. 130 North Front Street, Suite 202 Mailing Address 2d. Wilmington 2e. NC 21'. 28401 City State Zip 29. (910) 392-4462 21). (910) 392A612 21. Iburke&avanaughsolutionacom Telephone Facsimile E-mail NC PE Seal, Signature 8 Date FTA12107 r USE THE TAB KEY TO MOVE FROM FIELD TO FIELDI USE Number: (to be completed by DWQ) 1. Owner/Permittee: 1 a. Town of Pembroke Full Legal Name (company, municipality, HOA, utility, etc.) 1b. McDuffie Cummings, Town Manager 0 Signing Official Name and Title (Please review 15A NCAC 2T .0106 (b) for authorized signing officials!) 1 c. The legal entity who will own this system is: ❑ Individual ❑ Federal ® Municipality ❑ State/County ❑Private Partnership ❑ Corporation ElOther (specify:_ 0 1 d. 100 S. Union Chapel Road 1 e. Pembroke LL Mailing Address City 1f. NC 11g. 28372 Z j State Zip Code 0 _ 11h. ......_ (910) 521-9758 1i. (910) 521-0472 1j. mcduffie@pembrokenc.com QTelephone Facsimile E-mail V 2 Protect (Facility) Information J 2a. Town of Pembroke Union Chapel Pump Station & Forcemain .2b. Robeson a Brief Project Name (permit will refer to this name) County Where Project is Located CL Q ,3 Contact Person: 3a. Edward 'Ted" Burke, Cavanaugh & Associates, P.A. Q Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. (910) 392-4462 3c. tburke@cavanaughsolutions.com Phone Number E-mail 1. Project is ® New ❑ Modification (of an existing permit) If Modification, Permit No.: 2. Owner is ® Public (skip to Item 8(3)) ❑ Private (go to Item 2(a)) '2a. If private, applicant will be: 2b. If sold, facilities owned by a (must choose one) ❑ Retaining Ownership (i.e. store, church, single office, etc.) or, ❑ Public Utility (Instruction C) ❑ Leasing units (lots, townhomes, etc. - skip to Item B(3)) ❑ Homeowner Assoc./Developer (Instruction D) ❑ Selling units (lots, townhomes, etc. - go to Item B(2b)) 3. Town of Pembroke Z Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project 0 ;4a. Pembroke WWTP 4b. NCO027103 QName of WWTF WWTF Permit No. 5a. Town of Pembroke 15b. 6 inch ® Gravity 15c. WQCS00114 O Owner of Downstream Sewer Receiving Sewer Size ❑ Force Main Permit # of Downstream Sewer (Instruction E) ---- --- LL �6. __ T— The.origin of this wastewater is (check all that apply): PAY TO THE ORDER OF TOWN OF PEMBROKE ACCOUNT PAYABLE FUND P.O. BOX 866 PEMBROKE, NC 28372 LUMBEE GUARANTY BANK 66-368 005019 PEMBROKE, NORTH CAROLINA 531 THIS DISSURSEMENT HAS SEEN APPRO,ED AS REQUIRED BY THE LOCAL GOVERNMENT BUDGET AND FISCAL CONTROL ACT. CHECK NO. I CHECK DATE I VENDOR NO. 005019 03/25/2009 0000000933 **FOUR HUNDRED EIGHTY AND XX/100 DOLLARS'*'*"*'*"'******"'*'***'* CHECK AMOUNT $480.00 NORTH CAROLINA DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES Permit Number AVV0003420 Program Category Non -discharge Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer trent.allen Coastal SW Rule Permitted Flow 9000 Facilit Central Files: APS SWP 07/20/09 Permit Tracking Slip Status Project Type Active New Project Version Permit Classification 1.00 Individual Permit Contact Affiliation Facility Name Major/Minor Region Town of Pembroke Union Chapel Pump Station & Major Fayetteville Forcemain Location Address County Robeson Facility Contact Affiliation Owner Name Owner Type Town of Pembroke Government - Municipal Owner Affiliation McDuffiue Cummings 100 S Union Chapel Rd Pembroke NC 28372 Oates/Events Scheduled Issuance �— Orig Issue App Received Draft Initiated Public Notice Iss Effective Expiration 07/20/09 07/08/09 07 / 07/20/09 Regulated Activities Renuested/Received Events Wastewater collection Additional information requested Additional information received Outfall ' i.... Waterbody Name Stream Index Number Current Class Subbasin NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Governor Director July 1, 2009 CERTIFIED MAIL: 7008 1300 0001 1492 7830 RETURN RECEIPT REQUESTED Re: Town of Pembroke Union Chapel Pump Station and Force Main Dee Freeman Secretary Mr. Burke, I'm reviewing the application for the Town of Pembroke Union Chapel Pump Station and Force Main, and needed some additional information as well as parts of the application completed. I need information on the pump you are connecting the force main to —pump size GPM, current flow to this pump station. Also, please submit how you calculated your flow and complete section C of the application. I'm returning the application along with the check. Once you have the required information please resubmit it for review. If you have any questions, please contact me at 910-486-3322. Sincerely, Trent Allen 225 Green St., Suite 714, Fayetteville, NC 28301-5043 Phone: 910-433-3300 \ FAX: 910-486-0707 \ Customer Service:1-877-623-6748 Internet: www.ncwaterquality.org An Equal Opportunity \ Affirmative Action Employer NorthCarolina Naturallt� July 7, 2009 Trent Allen NCDENR - Division of Water Quality Systel Building 225 Green St., Suite 714 Fayetteville, NC 28301-5043 L11 CAVANAU G H Solutions through integrity and partnership Re: Town of Pembroke Union Chapel Pump Station & Forcemain Pembroke, Robeson County, North Carolina Dear Mr. Allen: Cavanaugh & Associates, P.A. on behalf of the Town of Pembroke hereby submits the following application to NCDENR - Division of Water Quality for review of the Fast -Track Application for Gravity Sewers, Pump Stations, and Force Mains for the above referenced project. This package also contains the additional information requested in your letter dated July 1, 2009. The subject project is located in Pembroke, Robeson County, North Carolina. To facilitate your review of the enclosed documentation, the following is an itemized breakdown: 1. A check in the amount of $480.00 to satisfy the fast -track review fee, made payable to 'NCDENR'. 2. Two (2) original application forms (FTA 12/07). 3. Two (2) copies of the Project Narrative. 4. Two (2) original Flow Tracking/Acceptance forms (FTSE 10/07). 5. Two (2) copies of a USGS color map identifying project area. 6. Two (2) original Watershed Classification Attachment forms (WSCAS 12/07). 7. One (1) copy of the pump station calculations. Please do not hesitate to contact our office should you have any questions, comments or require any additional information. Regards, CAVANAUGH & ASSOCIATES, P.A. Jeff Cappadona, E.I. Attachments cc: McDuffie Cummings, Town Manager, Town of Pembroke ` °'s r� Project Narrative Project Description Briefly, this project consists of the following improvements to the failing septic system at Union Chapel Elementary School, located at the intersection of Evergreen Church Road and Union Chapel Road in Pembroke, NC: • Installation of approximately 19,000 L.F. of 3" PVC (SDR 21) forcemain from Union Chapel Elementary School to the nearest sewer collection line down Union Chapel Road and a small pump station at the elementary school, eliminating the failing septic system. OF W ATFq State of North Carolina Q Department of Environment and Natural Resources 7r Division of Water Quality o Flow Tracking/Acceptance for Sewer Extension Permit Applications (FTSE—10/07) Project Applicant Name: Town of Pembroke Project Name for which flow is being requested: Town of Pembroke Union Chanel Pumn Station & Forcemain More than one FTSE-10107 maybe required for a .single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Pembroke WWTP b. WWTP Facility Permit #: NCO027103 All flows are in MGD c. WWTP facility's permitted flow 1.330 d. Estimated obligated flow not yet tributary to the WWTP 0 e. WWTP facility's actual avg. flow 0.67 f. Total flow for this specific request 0.009 g. Total actual and obligated flows to the facility 0.679 h. Percent of permitted flow used 51 % II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP Pump Station Name Approx. Capacity, MGD Approx. Current Avg. (Firm/Design) Daily Flow, MGD Jones Street Pump Station 0.144 MGD (Firm) 0.024 MGD III. Certification Statement: I, McDuffie Cummings, certify that, to the best of my knowledge, the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and 11 for which I am t responsible party. Signature of this form indicates acceptance of this wastwWater flow. Signature r ,' Date Instructions for: Flow Tracking/Acceptance for Sewer Extension Permit Applications (FTSE—10/07) Section I a. WWTP Facility Name: Enter the name of the WWTP that will receive the wastewater flow. b. WWTP Facility Permit #: Enter the NPDES or Non -Discharge number for the WWTP receiving the wastewater flow. c. WWTP facility's permitted flow, MGD: From WWTP owner's NPDES or Non -Discharge permit. d. Estimated obligated flow not yet tributary to the WWTP, MGD: This includes flows allocated to other construction projects not yet contributing flow to the collection system. Flows allocated through interlocal agreements or other contracts not yet contributing flow to the collection system are also included. For POTWs that implement a pretreatment program, include flows allocated to industrial users who may not be using all of their flow allocation. Please contact your Pretreatment Coordinator for information on industrial flow tributary to your WWTP. As of January 15, 2008 the POTW should have reviewed flow allocations made over the last two years and reconciled their flow records, to the best of their ability, so it is known how much flow has been obligated and is not yet been made tributary to the WWTP, in accordance with local policies and procedures employed by the reporting entity. The obligated flow not yet tributary plus actual flow will be reconciled annually for systems at less than 60% of permitted flow used. Annual updates shall be submitted to the appropriate Regional Office by January 15 of each year and cover the previous calendar year. Semi -Annual updates shall be required when the percent of permitted flow used reaches 60%. Semi- annual time period are defined as January 1 through June 30 and July 1 through December 31. Semi- annual updates shall be submitted to the appropriate Regional Office by July 15 and January 15 of each year. Quarterly updates shall be required when the percent of permitted flow used reaches 80%. Quarters are defined as Qtrl (Jan -Feb -Mar); Qtr2 (Apr -May -Jun); Qtr3 (Jul -Aug -Sep); Qtr4 (Oct -Nov -Dec). Quarterly updates shall be submitted to the appropriate Regional Office by April 15, July 15, October 15 and January 15 of each year. e. WWTP facility's actual avg. flow, MGD: Previous 12 month average. f. Total flow for this specific request, MGD: Enter the requested flow volume. g. Total actual and obligated flows to the facility, MGD Equals [d + e + fJ h. Percent of permitted flow used: Equals [(g / c)* 100] For example: On January 15 a POTW with a permitted flow of 6.0 MGD, reported to the Regional Office that there is 0.5 MGD of flow that is obligated but not yet tributary. The annual average flow for 2007 is 2.7 MGD. The first Form FTSE-10/07 submitted after January 15, 2008 may have numbers like this: c. = 6.0 MGD d. = 0.5 MGD e. = 2.7 MGD f. = 0.015 MGD g. = 3.215 MGD h. = 53.6 % The next Form FTSE-10/07 may be updated like this: c. = 6.0 MGD d. = 0.515 MGD e. = 2.73 MGD f. = 0.102 MGD g. = 3.349 MGD h. = 55.8 % Each subsequent Form FTSE-10/07 will be updated in the same manner. Section II List the name, approximate pump station firm (design) capacity and approximate current average flow (previous 12 months) through the pump station for each pump station that will be impacted by the proposed sewer extension project. Include the proposed flow for this project and other flows that have been approved for the pump station but are not yet tributary. Firm (design) capacity is the design average daily flow of the pump station as calculated by the design engineer or the station capacity with the largest pump out of service as per the Minimum Design Criteria if the design capacity is unknown. Section III Form FTSE-10/07 must be signed by the appropriate official as per 15A NCAC 02T .0106. TOWN OF PEMBROKE UNION CHAPEL FORCEMAIN ROBESON COUNTY NORTH CAROLINA a r t y r IL y s" {• ,,.?' a, 4 ,,. '• 1 ;!- d _ ^^ _ ;. ate... N , r • t'} , + �. ,,� R>.. _ a <.` (#1) UNNAMED TRIBUTARY. ^, » ► :� TO BURNT SWAMP a t � PROPOSED r . FORCEMAIN F i 1 .y. 7— (#2) MOSS NECK SWAMP`` ., 1 �' T (#3) UNNAMED TRIBUTARY TO MOSS NECK SWAMP ,...,,, _ : •� - ``" ' (#4) UNNAMED TRIBUTARY x a;•�' ?0 T BEAR SWAMP �;- P MY^.w yam. i (#5) BEAR SWAMP s I TIA.. r PROJECT INFORMATION SANITARY SEWER & STREET IMPROVEMENTS LATITUDE: LONGITUDE: QUAD #: STREAM CLASS: RECEIVING STREAM BASIN: STREAM INDEX #: 34°42'45.03"N 79' 82.81 "W PEMBROKE,NC WS-IV; Sw LUMBAR RIVER LUMBAR 1 4-1 0-8-4-(0.5), 14-9-3-(2), 14-9-(1.5) I 00� I CAVANAUGH Solutions through integrity and partnership 3 LOCATION NOT TO SCALE ICa✓anaugh 8 Assocml s, PA 1001 Wad, Avenue, S— 150, Raleigh. NC 27605 91912567494 Fax: 9191256-1499 —vnneughsolulbru.— 1 J .oF wArF9 State of North Carolina Department of Environment and Natural Resources T Division of Water Quality o .i WATERSHED CLASSIFICATION ATTACHMENT (WSCAS-12/07) FOR SEWER SYSTEMS The Division of Water Quality (Division) will not consider this attachment form to be complete unless all the instructions are followed. Failure to follow the instructions or to submit all of the required items will lead to additional application processing and review time. For more information or for an electronic version of this form, visit our web site at: http://www.nccgl.net/Engineering/Sewer%20Permits.html INSTRUCTIONS TO THE APPLICANT: A. Attachment Form: ✓ If the sewer system project area is a minimum of 100 feet from any surface water or wetlands, this classification is NOT necessary. If any portion of the sewer system project is within 100 feet of any surface water or wetlands, this form must be completed if there are proposed design conflicts with setbacks or buffers as listed in 2T .0305 (f).. ✓ Do not submit this attachment form for review without a corresponding permit application (Form FTA-12/07) unless requested by the Division. ✓ Any changes to this attachment form will result in the application package being returned. B. Prepare the attachment form with the requested information for each portion or location of the sewer system that is in conflict with a waterbody or wetlands. ✓ Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM WSCAS-12/07 (SEWER SYSTEMS)" to collect the stream classification data. This document is available from our web site at the address shown above or by contacting the appropriate Division of Water Quality regional office. ✓ The same Professional Engineer who certified the permit application form should seal this form. Different Professional Engineering seals may be accepted from engineers within the same firm. ✓ Submit an 8.5-inch by 11-inch COLOR copy of a USGS Topographic Map of sufficient scale to identify the entire project area and the closest surface waters. Each map or maps must show the location of the sewer line and pump stations and be of reproducible quality. For instance, the project involves 4 miles of interceptor sewer that traverses over or near several different waterbodies (or counties, basins, etc.). The map should have location ID's for each different waterbody (where the sewer line is within the setback/buffer) and corresponding classifications should be recorded. C. Include the attachment form and the map portions with the permit application for submittal to the appropriate regional office. ✓ A list of the Division's regional offices, their county coverage, and their contact information may be downloaded from the web site at: http://www.enr.state.nc.us/html/regionaloffices.html. ***THESE INSTRUCTIONS DO NOT NEED TO BE SUBMITTED*** INSTRUCTIONS FOR FORM: WSCAS- 12/07 FORM WSCAS-12/07 ��° wAr�,�pG WATERSHED CLASSIFICATION ATTACHMENT > FOR SEWER SYSTEMS Applicant Name Project Name Town of Pembroke Town of Pembroke Union Chapel Forcemain Professional Engineer Name Engineering Firm Name Edward Burke, P.E. Cavanaugh & Associates, P.A. Location ID Name of Waterbody' County River Basin Waterbody Stream Index No. Waterbody Classification Robeson Burnt 14-10-8-4-(0.5) WS-IV;Sw 2 Moss Neck Swamp Robeson Moss Neck Swamp 14-9-3-(2) WS-IV;Sw 3 U.T. To Moss Neck Swamp Robeson Moss Neck Swamp 14-9-3-(2) WS-IV;Sw 4 U.T. To Bear Swamp Robeson Bear Swamp 14-9-(1.5) WS-IV;Sw 5 Bear Swamp Robeson Bear Swamp 14-9-(1.5) WS-IV;Sw I If unnamed, indicate "unnamed tributary to X", where X is the named waterbody to which the unnamed tributary joins. l certify that as a Registered Professional Engineer in the State of North Carolina that I have diligently followed the Division's instructions for classifying waterbodies and that the above classifications are inclusive of the stated project, complete and correct to the best of my knowledge and belief. PE Seal, Signature and Date *** END OF FORM WSCAS-12/07 *** FORM: WSCAS-12/07 Page 1 of 1 Name of Stream Description Curr. Class Date Basin Stream Index # Redden Branch From source to Raft C;Sw 12/01/63 Lumber 14-10-4 Swamp Little Raft Swamp From source to Raft C;Sw 09/01/74 Lumber 14-10-5 Swamp McLeans Branch From source to Little C;Sw 09/01/74 Lumber 14-10-5-2 Raft Swamp Humphrey Branch From source to a point C;Sw 12/01/63 Lumber 14-10-6-(1) 0.5 mile downstream of Robeson County SR 1507 Humphrey Branch From a point 0.5 mile WS-IV;Sw 08/03/92 Lumber 14-10-6-(2) downstream of Robeson County SR 1507 to Raft Swamp Ausley Branch From source to Raft WS-IV;Sw 08/03/92 Lumber 14-10-6.3 (Circle T Lake) Swamp Mill Branch From source to Raft WS-IV;Sw 08/03/92 Lumber 14-10-6.6 Swamp Richland Swamp From source to Robeson C;Sw 09/01/74 Lumber 14-10-8-(0.5) County SR 1509 Richland Swamp From Robeson County SR WS-IV;Sw 08/03/92 Lumber 14-10-8-(2.5) 1509 to Raft Swamp Long Swamp From source to C;Sw 09/01/74 Lumber 14-10-8-1 Richland Swamp Wilkes Branch From source to C;Sw 09/01/74 Lumber 14-10-8-2 Richland Swamp Panther Branch From source to Robeson C;Sw 09/01/74 Lumber 14-10-8-3-(1) County SR 1509 Panther Branch From Robeson County SR WS-IV;Sw 08/03/92 Lumber 14-10-8-3-(2) 1509 to Richland Swamp Burnt Swamp From source to N.C. C;Sw 09/01/74 Lumber 14-10-8-4-(0.2) Hwy. 72 Burnt Swamp From N.C. Hwy. 72 to WS-IV;Sw 08/03/92 Lumber 14-10-8-4-(0.5) Richland Swamp Little Burnt From source to Burnt WS-IV;Sw 08/03/92 Lumber 14-10-8-4-1 Swamp Swamp White Oak Branch From source to Raft WS-IV;Sw 08/03/92 Lumber 14-10-9 Swamp Powell Branch From source to a point WS-IV;Sw 08/03/92 Lumber 14-10.5-(1) 0.5 mile upstream of mouth Powell Branch From a point 0.5 mile WS-IV;Sw,CA 08/03/92 Lumber 14-10.5-(2) upstream of mouth to Lumber River Saddletree Swamp From source to Lumber C;Sw 07/01/73 Lumber 14-12 River Rocky Branch From source to C;Sw 07/01/73 Lumber 14-12-1 Saddletree Swamp McEacherr Branch From source to C;Sw 07/01/73 Lumber 14-12-2 Saddletree Swamp Poplar Pole From source to C;Sw 07/01/73 Lumber 14-12-3 Branch Saddletree Swamp Page 2 of 9 2009-03-07 05:27:57 %A . Name 'of Stream Description Curr. Class Date Basin Stream Index # Mill Branch From source to Lumber C 12/01/63 Lumber 14-6 River Back Swamp From source to Robeson C;Sw 08/03/92 Lumber 14-8-(0.5) County SR 1157 Back Swamp From Robeson County SR WS-IV;Sw 08/03/92 Lumber 14-8-(2.5) 1157 to Lumber River Double Branch From source to Back C;Sw 08/03/92 Lumber 14-8-1 Swamp Cypress Branch From source to Back C;Sw 08/03/92 Lumber 14-8-2 Swamp Turkey Branch From source to Robeson C;Sw 08/03/92 Lumber 14-8-3-(1) County SR 1158 Turkey Branch From Robeson County SR WS-IV;Sw 08/03/92 Lumber 14-8-3-(2) 1158 to Back Swamp Little Back Swamp From source to Back WS-IV;Sw 08/03/92 Lumber 14-8-4 Swamp Bear Swamp From source to Robeson C;Sw 08/03/92 Lumber 14-9-(0.5) County SR 1515 Bear Swamp From Robeson County SR WS-IV;Sw 08/03/92 Lumber 14-9-(1.5) 1515 to Lumber River Little Bear Swamp From source to Bear C;Sw 08/03/92 Lumber 14-9-1 Swamp Watering Hole From source to Bear WS-IV;Sw 08/03/92 Lumber 14-9-2 Swamp Swamp Moss Neck Swamp From source to Robeson C;Sw 08/03/92 Lumber 14-9-3-(1) County SR 1576 Moss Neck Swamp From Robeson County SR WS-IV;Sw 08/03/92 Lumber 14-9-3-(2);`: 1576 to Bear Swamp Kersey Branch From source to Bear WS-IV;Sw 08/03/92 Lumber 14-9-4 Swamp Jacks Branch From source to Lumber WS-IV;Sw 08/03/92 Lumber 14-9.5 River River Swamp From source to C;Sw 12/01/63 Lumber 15-25-1-6 Lockwoods Folly River Big Branch From source to B 09/01/74 Cape Fear 18-31-20.3 Rockfish Creek Page 9 of 9 2009-03-07 05:27:57 CAVANAU G H Solutions through kltegrity and partnership Pump Station Des! Calculations 1 30 NORTH FRONT STREET, SUITE 202 Project No.: 041,08.018 v� 1 WILMINGTON. NORTH CAROLINA 213401 • 91 0.392.4462 • 9 1 0.392.461 2 WWW.CAVANAUGHSOLUTIONS.COM CAVANAUGH Wastewater Daily Flow Table rb r n 0 Barber Shops Gal/Chair 50 0 Beauty Sho s Gal/Booth or Bowl 125 0 offices0 General business and office facilities G&VEmployeeMift 25 0 Factories excluding industrial waste Gal/Em o ee/Shift 25 0 Factories or businesses w/ showers or 0 food preparation Gat/Employee/Shift 35 0 Warehouse Gal/Loading Bay 100 0 Warehouse - self storage not Including 0 caretaker residence GaVtJr>it 1 0 hurches 0 Churches w/o kitchens day care or camps Gal/Seat 3 0 Churches with kitchen Gal/Seat 5 0 Churches providing day care or camps lGal/Person child & em ee 25 0 0 Fire or rescue stations w/o on site staff Gal/Person 25 0 Fire or rescue stations with on -site staff Gal/Person/Shift 50 0 ricilitles 0 Banquet, dining hall Gat/Seat 30 0 Bars, cocktail lounges Gat/Seat 20 0 Caterers Gal/100 sq. ft. floor space 50 0 Restaurant full Service GaVSeat 40 0 Restaurant,single service articles Gal/Seat 20 0 Restaurant, drive -In Gal/Cer space 50 0 Restaurant, carry out only Gal/100 sq. ft floor space 50 0 Institutions, dining halls Gal/Wal 5 0 Deli Gal/100 sq. ft. floor space 40 0 Bake GaV100 sq.ft. floor space 10 0 Meat department butcher shop or fish market GaV100 sq. ft floor space 75 0 Specialty food stand or kiosk GaV100 sq. ft. floor space 50 0 0 Hotels, motels and bed & breakfast facilities, 0 without in -room cooking facilities Gal/Room 120 0 Hotels and motels, with in -room cooking 0 facilities Gai/Room 175 0 Resort hotels Gal/Room 200 0 Cottages, cabins Gal/Unit 200 0 Self service laundry facilities Gal/Machine 500 0 I 0 Medical or dental offices Gal/Practitioner/Shift 250 0 Veterinary offices not including boarding) Gal/Practitioner/Shift 250 0 Veterinary hospitals, kennels, animal 0 boarding facilities GaVpen, cage, kennel or stall 20 0 Hospitals, medical Gal/Bed 300 0 Hospitals, mental Gal/Bed 150 0 Convalescent nursing, rest homes w/o 0 laundry facilities Gal/Bed 60 0 Convalescent nursing, rest homes with 0 laundry facilities Gal/Bed 1201 0 Prepared By: www.cavanaughsolutions.com Cavanaugh $ Associates, P.A. 130 North Front Street, Suite 202 Wilmington, NC 28401 1of10 0 , r CAVANAU G H RmAdential care facilties Gal/Person 60 0 0 v f 0 Campgrounds w/comfort station, w/o water 0 water or sewer hookups GaVCampsfte 75 0 Campgrounds w1water & sewer hookups Gal/Campsite 100 0 Campground dump station faciQ Gal/Space 50 0 Constriction hunting or work carnps with 0 flush toilets Gal/Person 60 0 Construction hunting or work camps with 0 chemical or portable Idiots Gal/Person 40 0 Parks with restroom facilities Gal/Plumbing fixture 250 0 Summer camps without food preparation 0 or laundry facilities Gal/Person 30 0 Summer cam w/food preparation 6 0 laundry facilities Gal/Person 60 0 Swimming Is, bathhouses and spas Gal/Person 10 0 Public access restrooms Gal/Plumbing fixture 325 0 Schools, preschools and day cam 0 Day care and preschool facilities Gal/Person child 8 employee) 25 0 Schools w/cafeteria, gym and showers Gal/Student 15 0 Schools w/cafeteria Gal/Student 12 750 9000 Schools w/o cafeteria or showers GaUStudent 10 0 Boarding schools Gal/Person student & employee) 60 0 jawce . car wash facilities- 0 Service stations, gas stations Gal/Plumbing fixture 250 0 Car wash facilities if recycling water see 0 Rule .0235 G&VBay 1200 0 0 Bowling center GaW-ans 50 0 Fitness exercise karate or dance center Gal/100 sq. ft. 50 0 Tennis, racquet ball Gel/Court 50 0 Gymnasium Gal/100 sq. ft. 50 0 Golf course w1only minimal food service Gal/Plumbing fixture 260 0 Country Clubs Gal/Member or Patron 60 0 Mini golf, putt -putt Gal/Plumbing fixture 250 0 Go-kart, motocross Gal/Plumbing fixture 250 0 Batting cages, driving ranges Gal/Plumbing fixture 260 0 Marinas without bathhouse Gal/Slip 10 0 Marinas with bathhouse Gal/Slip 30 0 Video game arcades, pool halls Gal/Plumbing fixture 250 0 Stadiums, auditoriums, theaters community 0 centers Gal/Seat 5 0 0 markets 0 Auto, boat recreational vehicle 0 dealershi stshowrooms w/restrooms Gal/Plumbing fixture 125 0 Convenience stores, w/food preparation G911100 sq. ft. 60 0 Convenience stores, w/o food preparation Gal/Plumbing fixture 250 0 Flea markets GaI/Stall 30 0 Shopping centers & malls w/food service GoV1000 sq. ft 130 0 Stores & shopping centers w/o food service GaV1000 sq. ft 100 0 Transportation terminals - air, bus, train 0 ferry, and dock Gal/Passenger 5 0 Prepared By: www.cavanaughsolutions.com Cavanaugh & Associates, P.A. 130 North Front Street, Suite 202 Wilmington, NC 28401 2of10 CAVANAUGH 0 34edroom Units Gallbedmornklay 120 `' fl 0 e-esdroom units Gallbedroornklay 120 0 0 Total• ta000 Prepared By. www.cavansughsolutions.com Cavanaugh & Associates, P.A. 130 North Front Street, Suite 202 Winik gton, NC 28401 3of10 CAVANAU G H Pump System Design Spreadsheet • C-120 Pro;e:t Uno,Cha;c SCtAd P$ 6F14 Loca"an Roteac,Co�nrr, t:C Des9n By was Prdeot No: 041.03618 Vent T.-of Pemt'04 C+ecYed By Woo Oatr 2l2312CC9 Pm;ect Oawrvtp 6ct4UTa^am ass, P-P Sts'o, ovatent Reouj19IDfir" Lu-9ln of P;e 19000 R : R Da fFcarCe • 9,000 QPd Egx.a'e-t Len9Lh 19,150 R R Dea2n Perod • 6 hrt PIP* Dimeter 3 In : a fn A,.,.;* Flcn • 19 gpm E'r.ata, D,Tannce 10 R Peeing Fades• 250 P pe Area 0049C1173%Ra Peal Flo, 47 gpm V 141E 05 Ralase. 6 0000005 R Ptewxe Heat • 0 R C 120 °n 0.0160258 Duty Points: 1 Pump: $0.6 op. @ 202 4 2,259 Naec Myer 2 Pump: 618 gpm C 212 R. 235 Naec Y1OXiCOH }yatem Curve Sttp 2 F"We Flonnte Vabcty Rern9'da 7 (GPM) (Resless:) (Rhao) Numtar 0 0 0 0 Coo, :Do 0 2 000448 009 1810E01 OV3976 4 00069t 0..14 3219E•03 004349 6 001337 021 4829E-03 003828 0.01782 0.38 8.43eE+03 0.0512 10 002228 0,45 &NSE-03 003294 t2 0.02674 064 9.657E+03 0 03131 14 0.031lg OH 1.127E+C4 003002 1¢t 003SAS - 073 f283E+04 002897 18 004010 002 1449E+C4 0o28C8 20 0C4454 1101 1.610E+04 002733 22 004M 100 1.170E-04 002d67 24 0.05347 1A9 1,031E+04 002M 28 0.05703 Us 2092E+C4 0025S5 0.06238 127 2263E-C4 002511 30 006684 1.38 2414E+C4 002469 32 0-07130 1.0 2675E-04 002431 34 007576 1.54 2738E+C4 002358 30. Do6021 163 2697E-C4 002363 33 0084" 172 3058E-M 002333 40 008912 t O 3219E+04 002305 42 0093$8 191 3360E-04 002279 44,: 009S03 2.60 3641E+64 0022S4 4a 0,10249 209 3702E+04 002231 46 O.1004 2.1$ 3683E+04 002209 6o 0.11140 227 4024E-D4 002169 02 0.11566 238 4166E-C4 002169 64 0.12031 245 4.348E+04 002151 56. 0.12477 254 4601E+04 002133 84 012922 263 4688E+04 0.02117 00 0.133611 2.72 4829E+04 00210t 62 0.13814 291 ASSOE-o4 002065 64 014269 246 5.160E+04 002071 es 014705 303 53t t E-04 002057 6J 0,16150 9,00 6472E-04 002043 70 0.165M 318 6633E+C4 002030 7Y 0,16042 321 6.794E-C4 002018 74- 0.16487 3.38 595SE-C4 002006 70. 0,16933 s45 6.116E-C4 001094 78 017378 3.54 6277E-C4 001983 60. 0.17824 363 6.438E+C4 0019T2 82 018270 372 6599E-04 001962 0 0,18715 Set 0.760E+C4 001952 66 019161 3.90 6921E-04 001942 0 019606 3." 7.082E+04 001932 90 020052 408 7243E-C4 001923 G2. 020493 4.18 7.4C4E+04 001914 H 020943 427 7.565E-04 0.019W so:. 021381 435 7.728E+04 001897 Qa 02t634 4.45 7.687E+04 001869 100 022260 k54 8046E+04 001681 102 022726 4.63 8 209E-04 001873 104 ' 023171 4:.72 8 370E+CA 0 08" 108 023617 491 6 530E.04 0016511 106 024062 4,90 8691E+04 001651 110 0 2450a 499 8 652E+04 0 Gle44 112, 024954 &06 9013E+C4 001637 114 025399 5,17 9114E+04 001831 Ito 026646 127 0335E-C4 001824 lie 026290 538 8.498E-04 101816 120 02673a 6.45 9.857E+C4 0018t1 122 027182 554 98feE-C4 oote05 124 027827 6.63 097frE+C4 0017f9 128 028073 6.72 1.014E+CS 001793 120 026518 6V 1.030E+05 0.017" 130 026964 6.90 1.046E-CS 0.01762 In; 029410 A99 1.062E+05 0.01777 134 029a55 0.06 1.076E-05 007771 138 0.30301 &17 1,094E+05 0 Was 5oeol no Owrat;M PMMa: 50.5 011251 229 4 084E+04 002194 51.6 0 11 541 235 4109E-04 002171 Mrvra:t.rela P_mp Cum. Data Frc'.on Kea! [4Vatan Held Ve'ccty Haad Pnasun Head TOM TOM in 10 0 „m Oo�tl 3.74 1m to &Do 0 .t. .060 962 TO 0.00 0 17.92 22.04 t0 001 0 -�. 6:01 2852 3446 10� o01� 0 41.35 4567 10 0.02 0 Ct1.32 154 SO t0 002 0 7339 26691 10 003 0 . 8 102.83 10 1Q,� W', WA 113 C4 t0 005 a 13a.76 14905 t0 006 0 r Yom 181.63F4 t a 07 0 188-62 t0 0.06 0 217.71 232.66 10 006 a r 24848 244.66 0a 10 all 281,11 204,11 10 6.12 0 315.U333.50 itl t1 35107 t0 011 0 37069 35307 ,.. .10 01111 �,,• 0 . 450.47 3 :q. 471.53 10 493.02 5140 10 637.33 Rffl MO 14 10 US 32 t6 ° i7: 'ti 607,07 10 631.18 4o 65572 90 68069 e :10 ; 708 09 10 73192 753.17 7114 65 81195 t0 93947 Al... . , 1 UT41 10 39577 ', 02455 10 96375 t0 11337 10 1013-40 9U ° : 104365 10 1074.70 110523 i0 1137.86 116976 10 120226 :.to 192 33 10 0.08 0 202 201 59 10 009 0 212 216 211 204 3' D I P.Fa 6D 1 P.P. 9t, Dexr;ctO' EauV Lyg-biRl Total Lara'h IRI Qt Q82;r'alon €ov`>. Leru!h IIITe+al Lengh IR1 2 PL2 Va`:e 25 50 0 P,-1 Vah1 46 0 0 AN'. W4a 40 0 0 Any a VaYa 96 0 1 Ct."Va`.a 24 24 0 Chace va`.1 51 0 0 Gates Ve.1 2 0 0 Gate va".1 4 0 3 90 deg Eton 7 21 0 90 deg Eton 15 0 10 45 dig E ton 4 40 0 45 deg E to, 6 0 - 1 Tee 16 t5 0 Tee 30 0 Total Eq'+N. Length: ISO Total Egob. Length 0 Prepared By. vNAv.cavanaughsotutions.com 4 of 10 Cavanaugh & Associates, P.A. 130 North Front Street, Suite 202 Wilmington, NC 28401 CAVANAUGH Pump System Design Spreadsheet - C=140 Protect Ucon C,apef Sch_v1 PS 9 FM Luee- Rohien Ca:-4y. NC C., On of WOS Protect No 041 08 018 C14,1 To., 01 Pembroke CM<ked By WOS 0i.4 2/23/2009 Protect Cowpto, Ir•uent Pump Sta•.on Svihm R40utremen1e Le 7h 0 P.F. 19,000 it 8 y Fl Do onr4:e 0,000 Op" Egc:•a'lnt L-gth 19'150 R 8 Do. p•Pericd a hr4 P pe O■meth 3 In 6 P A -;,Flo.• 19 gpm E'4mt-Ddference 10 8 Peakrg F.;!.,• 260 P,pe Aria 00490a739 ft7 Peak Flo. • 47 gpm v 1 41E.05 R1Ar E 0000A5 it Preaavi HW 0 R C 140 m v 0.0160258 Duty P.4m.: 1 Pump: 46.5 gpm m 200 e. 2.66 6looc Myen 2 Pump: 802 ppm a 210 it, 2.73 fUeeo VK3)C7 COH f2a-u�a_twefi Svitem Curve Step 2 P.mp Curve Data Fkmm.4 Fb*m:4 Ve'Oc y Rey 'z r friction Head Ewotan He8d Vebc4y Heed P.-Hood TOM TDH (GPM) (Bahr) (6Aw) Ntmber let at (6) Rt R) (e) 0 0 -0 0.000E-00 0 0.00 .;.,` 0.1) ".„f4611r$d.� ::. ,. 2 0.00440 0.09 1-610E-03 003278 0.37 t0 000 0 10 !- { 009 0.01 OAS 3219"e-03 004349 4M v 000 001337 027 4.829E-03 00382a 2a1 000 0 13 3 0.01782 IS"0.436E-03 0 63512 4Tt 000 4,40e 10 002226 0.45 6048E-03 003204 723 000 0 17 1 12 °0M74 8,64 90.57E-03 003131 10. 0.00 - 14 003119 0.64 1.127E+C4 003002 1347 0.01 0 1 16 003565 0.73 1288E-C4 002897 111$ to 004DIO 042 1449E-C4 0026Ca 21AS 0.01 0 $1 216 21. 0.04456 001 1.610EK4 002J,» 20,06 ilt 22 004902 1.00 1.770E-C4 002687 3109 002 0 41 24 005347 1.01 1.931E-C4 002e09 3a62 20 005793 118 2092E+C4 002558 4234 Q02 0 62 29 0cam I" 2253E-C4 002511 4a 67 N § 211 30 0c6a84 S.3e 2414E-C4 002469 05.16 003 0 65 32 007130 1,1E 2675E-C4 002431 0111 ' 003 34 007575 V64 2.736E+C4 00239d 6956 0.04 0 60 is 008021 _1.53 2897E-C4 002363 771C--. 38 00840 1.72 30'.8E•C4 002333 6545 0.05 0 95 20a ? 40 0.08912 10i 3219E-G 002305 93.95 '(" 0,05 :. •.�, 42 009358 1.91 338CE-C4 002279 10263 ,. w CLOG -, 0 N3 .t: M 069603 200 3651E-04 002251 11207 . ,•, 40 0.10249 269 3.702E-C4 002231 121.67 10 007 0 432 -. 46 010694 118 3863E-C4 002209 131.04 '_AWM30WQOV ;: ��*�,�''", 204 50 0.11140 227 4.024E-C4 002169 141.97 t0 0.09 0 132 E2. -. 0,11sea 2,.3E 4.185E-04 00209 15265 s H 0.12031 245 4.348E+04 062151 16369 10 0.09 0 174 ' N 0.12477 264 1507E+C4 002/33 37609 10 �? }'=_O:W � ,ij r m' - 201 be 012M 243 4685E-04 002117 16863 10 0.11 . 0 197 b 013360 2-72 4629E-04 002101 16692 LO 62 0.13814 2411 4020E-04 002085 21L36 10 012 0 221 `;• . : 014252 2-90 6.150E+04 002073 224.16 ,.°1,�43 .• w 60 014705 300 6311E-04 002057 237.28 t0 0.14 0 247 6i 015150 3-00 6472E-04 002043 250.75 :t0 :06 70 0.1650 316 5633E-04 002030 264.56 t0 0.16 0 276 ,?2. 0.16042 327 91 E•C4 002016 27672 ;15 74 O.t6467 336 6955E+04 002006 29321 10 0.14 0 303 016933 145 6.115E-04 0019" 30804 -90 Os 7a 0.17378 354 8277E-04 001963 32320 10 0.19 0 us. + q 0.17824 3.83 6436E+04 001972 33870 16 ,'. .020 r. e306 92 018270 3,72 6599E+04 001902 354.53 10 0.22 0 64 018715 301 a.76IJE+C4 001052 370.09 ,#0 023 ;+? "r;� ee 0.19181 3.60 6921E-04 001942 387A9 10 024 0 6a7 16 olWe 399 7.082E-04 001032 404.01 10 ! 023 p, .`... r ..- 90 020052 4.08 7243E+04 001923 421,16 10 026 _ 0 431 92 0.20498 4AO 7.404E-04 001914 43a 64 :.10 027 94 C20943 427 7.585E-04 0019C6 450.44 10 028 0 457 • as 021! '4,35 7,716E-04 001847 47467 0 . •.: 020 9a 021 a34 445 7.897E-04 001669 49302 t0 0.3t 0 603 100 022260 4.54 e046E+04 001681 51160 _%- 041 ;,. '_ -'- -„ M 102 022721 463 6209E-04 001873 63090 10 0.33 0 SO 104 023111 472 a 370E-04 00166E 550.31 ;gip Q35 ` , 106 023817 4.61 6530E-04 0.01653 67005 10 036 0 640 lot 014062 400 8691E-04 0018S1 590.11 �i0 • Q37 a- ;- ?�0 110 07450a 4.69 a652E•04 001844 61049 10 0.39 0 621 112 024954 6C9 9013E-04 001837 63118 10 0.40 'i3 'yf - '�;_ 69 114 025399 6.17 9174E-04 00t831 65219 f0 042 0 963 Ito 025445 6.27 0335E-04 001824 67361 % 0.43 � ' ; US 71s 026290 638 9495E-04 001636 697516 10 0.45 0 700 : f20 026736 645 9657E-04 001611 7/7.t/ 10 - 0- AM 7116 111 027111 554 9916E-04 001605 73931 10 0,48 0 750 124 027627 5.63 9979E-04 001799 741.% '.1E _ 049 -.. ... 126 02a073 6.72 1014E-05 101793 )6411 f0 051 0 7% 124 028518 6.61 1.030E-. 00178a we05 '40 , -. Q62 130 028964 690 1048E-05 001762 $31,56 10 0,54 6 942 132 0-29410 6.99- 1.OM-05 001T77 85S38 0 . 0." � 1. �C`400 134 0 298S5 6.ol 1 076E-05 001771 07951 10 057 6 no0.3 138 0701 6.17 1.094E+05 0.0116E 90305 :10 _ S tt .18c Ourilin0 OeIM4: 115 013034 26-3 4708E-04 002112 1N 62 10 O11 0 200 EO 2 0 13413 2 73 4 645E-04 0 02M 203 15 10 0 12 0 210 3D I RC9 a 1. P;e ctr,"10n E", Le. hf81 jg.al Leah fel Zi Di4cr;O.o+ EOu`rWMh(a ToW Lor,th f8l 2 P;ug V.1io 25 60 0 P:u2 V.`" 4a 0 0 A,,. V.Y. 40 0 0 A-24 V."76 0 1 CMc'c Vo`.a 24 24 0 Check Va`:4 51 0 0 Ga.e V.". 2 0 0 Ga.e Va`.1 4 0 3 40 deg Etc. 7 21 0 90 dig Ebc. 15 0 10 45 deg E tc. 4 40 0 45 deg Ebc. 6 0 1 To s 15 15 0 Tee 30 0 Toa Eq.Y Length. 150 TOW E9':V L4rgh 0 Prepared By: LwAv.cavanaughsotutions.com 5 of 10 Cavanaugh 81 Associates, P.A. 130 North Front Street, Suite 202 Wilmington, NC 28401 250 0012 230 w d d c 210 m x 200 �a 0 cc 190 0 180 170 160 150 a R CAVANAUGH INFLUENT PUMP STATION PUMP VS. SYSTEM CURVE Yr. 20 Service Yr. 1 Service (C=120) Duty Point = (C=140) 51.8 gpm @ 212 ft. Velocity = 2.35 fps. 2 Pumps Duty Point = 60.2 gpm @ 210 ft. I --------------------- Velocity = 2.73 fps. Duty Point = I I I I 50.5 gpm @ 202 ft. I Velocity = 2.29 fps. I I 1 Pump I I Duty Point = I I l l j 58.5 gpm @ 200 ft. I 1 I I l 1 1 Velocity = 2.66 fps. I I I I I I I— I I I I I I I 1 I O O CV Cl) Prepared By: Cavanaugh & Associates, P.A. 130 North Front Street, Suite 202 Wilmington, NC 28401 O O O O u7 O Flowrate (gpm) www.cavanaughsolutions.com O O O OD O O V- 6 of 10 • . •0 1 CAVANAUGH Pump System Design Spreadsheet Project: Union Chapel School PS & FM Location: Robeson County, NC Design By: WGS Project No: 041.08.018 Client: Town of Pembroke Checked By: WGS Date: 2/23/2009 Project Description: School Transmission Pump Station Duty Point (From System vs. Pump Curve) Wet Well Diameters,, Area Active Depth Active Volume ADF PDF Cycle Time (Tc) Tc (ADF) _ Tc (ADF) Cycles/Hr ■ Tc (PDF) ■ = 6 ft. = 28.27 sq.ft. = 1.00 ft. = 28.27 cu.ft. = 211.51 gallons = 19 gpm = 47 gpm Q = 50.5 gpm TDH ■ 202 ft. Active Volume (per NCDENR) 177 gallons V = TQddf (1-(Qddf/0)) Where: V = Active Volume Required (gallons) T ■ Allowable Cycle Time between starts (minutes) Qddf = Design Daily Flow (gallons per minute) 0 ■ Pumping Rate of a Single Pump (gallons per minute) Active Volume + Active Volume Pumping Rate - ADF ADF 17.94 minutes 3.34 Active Volume + Active Volume Pumping Rate - PDF PDF Tc (PDF) ■ 62.86 minutes Cycles/Hr ■ 0.95 Pump Run Time (R0 Rt (ADF) = Active Volume Pumping Rate - ADF Rt (ADF) = 6.66 minutes Rt (PDF) = Active Volume Pumping Rate - POF Rt (PDF) = 68.35 minutes RIM = 173.00 Finished Grade = 172.50 Invert In = 165.50 Minimum Liquid Level = 18 Auto Dialer Alarm = 167.50 High Level Alarm 165.50 Lag Pump On = 165.13 Lead Pump On = 164.75 Minimum Liquid Level ■ 163.75 Bottom of Wet Well = 162.25 Depth of Wet Well ■ 10.75 Depth Below Grade 10.25 Prepared By: Cavanaugh & Associates, P.A. 130 North Front Street, Suite 202 Wilmington, NC 28401 Inches (manufacturer requirement) (Invert of Influent Pipe) (Lag Pump Off) (Lead Pump Ott) wvNi.cavanaughsolutions.com 7of10 CAVANAU G H Pump System Design Spreadsheet Project: Union Chapel School PS 6 FM Location: Robeson County, NC Design By. WGS Project No: 041.08.018 Client: Town of Pembroke Checked By WGS Date: 2123109 Project Description: School Transmission Pump Station Force Main Turnover Calculation Length of Pipe 19,000 ft Pipe Diameter 3 in Pipe Area 0.0490874 ft Force Main Volume 933 It' = 6,977 gallons Pumping Rate = 50.5 gpm Tumover Time a 138.15 minutes (Continuous Pumping) 2.30 hours Tumover Time (ADF) „, t .. _ ,6.20 hour (Real Time) Tumover Time (PDF) _,.148 hours (Real Time) Prepared By: m-Av.cavanaughsolutions.com Cavanaugh & Associates, P.A. 130 North Front Street, Suite 202 Wilmington, NC 28401 8of10 CAVANAUGH Pump System Design Spreadsheet Project: Union Chapel School PS & FM Location: Robeson County, NC Design By: WGS Project No: 041.08.018 Client: Tovm of Pembroke Checked By WGS Date: 02/23/09 Project Description: School Transmission Pump Station Buoyancy Calculation 'Note: Sum of Downward Forces must be greater than Sum of Buoyant Forces Assumptions: 1.) Neglect weight of liquid in wet well, access doors, grout bed, pumps & appurtenances. 2.) Super -saturated conditions (groundwater at surface) 3.) Unit Weight of Concrete 150 Ib.W 4.) Unit Weight of Water 62A Ib.Ht' 5.) Unit Weight of Buoyant Sand ■ 60 lt)At i Downward Forces: Sum of Downward Forces = FT,, + FR, + Fs_ + Fs;j Concrete Top: Inside Diameter of Wet Well A 6.00 ft Wall Thickness B = 6,00 In Diameter of Concrete Top C = 7,00 ft Thickness of Concrete Top D 12.00 In Hatch Length G = 4.00 ft Hatch Wdth H = 3.00 ft Area of Concrete Top = 38.48 ft? Volume of Concrete Top = 38,48 ft3 Area of Hatch 12.00 ft, Volume Void Due to Hatch 12.00 ft, FT, _ (Vol. of Concrete Top - Vol. of Hatch Void) x Unit Weight of Concrete FTep 3,9731bs. Concrete Riser: Inside Diameter of Wet Well A = 6.00 It Wall Thickness B = 6.00 in Outside Diameter of Wet Well E = 7.00 ft Depth of Wet Well F = 10,60 ft Area of Concrete Riser = 10.21 ft, Volume of Concrete Riser = 107.21 ft3 FFt _ = V01. of Concrete Riser x Unit Weight of Concrete Fa,,, W081 lbs. Concrete Base: Outside Diameter of Wet Well E = 7.00 ft Extended Base Beyond Wet Well 1.50 ft Diameter of Concrete Base = 10.00 ft Thickness of Concrete Base = 1200, In Area of Concrete Base = 78.54 ft, Volume of Concrete Base = 78.54 ft, (i ft. Minimum) Prepared By: %,A-m.cavanaughsolutions.com Cavanaugh & Associates, P.A. 130 North Front Street, Suite 202 Wilmington, NC 28401 d C rffff] ID H G ' A B F 9of10 a , 4s ` . CAVANAU O H Few ■ Vol. of Concrete Weer x Unit Weight of Concrete Few ■ 11,781lbs. Soil Over Extended Bass: Outside Diameter of Wet Well ■ 7.00 4 Dlamelerof Concrete ease = 10.00 It Depth of Soil • 10.00 It Area of Soil Over Base 40.06 fe Volume of Soil Over Base 400.55 ft' Fw = Vol. of Concrete Riser x Unit Welyhl of Concrete Fs,I 24,033 lbs. I Fw,. , = FTw + Fg,+ Fw. + Fso I Fs ,a ■ 55,666 lbs. I Buoyant Forces: Sum of Buoyant Forces = Volume of Water Displaced x Unit Weight of Water Volume of Water Displaced by Riser ■ 635.17 ft? Volume of Water DWaced by ease 76.54 ft' Total Volume of Water Displaced 714.71 le I F,,, = 44,596 lbs. Factor of Safety: FS IFS Minimum factor of Safety 1.25 FS 1.25 Prepared By: www.cavanaughsolutions.com Cavanaugh S Associates, P.A. 130 North Front Street, Suite 202 Wilmington, NC 28401 *- AREA OF SOIL OVER BASE 10 of 10