HomeMy WebLinkAboutNCC203177_Site Plan or Location Map_20200727N
CL RIW
48'
PER Fr 1
...•.....:..:.:.:.:.:. •.:811 ABC 4 o
2" S9.,' SUPERPAVE ASPHALT
SECTION A -A
SYMMETRICAL CUL-DE-SAC
WITH 126' R/W RADIUS
NO CURB AND GUTTER
NTS
25' TE
11
250' REE &
TATION
CL R/W
35'
.........:.:.:.:.:.:.:........ .
"PER FT. 1
8"ABCM1 47 n
2" S9.,' SUPERPAVE ASPHALT
SECTION A -A
SYMMETRICAL CUL-DE-SAC
WITH NO CURB AND GUTTER
NTS
RIG E & FL HALL
U.B. 1 . 0
IN# 0 7- 720
BE TAIN
W 1 0. PAC.)
alvelmill
{
611
5'
VAR.
6'
8'
PAVEMENT
SHOULDER
WIDTH
WIDTH
1/4"/FT
OR
+�6%
-2.08% +8%
-8.33% -187
OR
1"/FT
SHOULDER SECTION
DRIVEWAY TURNOUT GRADES
N � _I♦ram
- � - •I• n
-9
LEGEND n '
7,000 SF = MAXIMUM IMPERVIOUS ALLOWED 3
L
= FLOOD HAZARD SOILS
4
+ + +
+ + + = WETLANDS
i
I
70' 50' TAPER
(REWIRED FOR W
25' LESS THAN 26')
,o• p xx o
R= 3 30'MIN. R= 30' 25 R SIGHT TiIAfJGLE
R W I R W
R= 30' R= 30'
STOP
EDGE OF PAVEMENT EDGE OF PAVEMENT
EDGE OF PAVEMENT EDGE OF PAVEMENT
EXISTING ROAD
R W R W
RECOMMENDED ROAD CONNECTION
STOP CONDITION
sm
:- �\.♦` . �� : � �� � ` � � - is � - • �. r l���jJ ` �. �i � 1
♦ \� f ✓ /ON• .
wl
• •` \ . . ..
FINE,
0 .' f
• 111 . .Ill 119 _' ♦ �� � '� � ��/
WE Ndl
i IN
f
��� _ �' � err C"� • � `/ I � � �� � � +
��� " � 1, •�� // �I
�,. = / � _I/nib ����!� . - • • 1 . �i=Ord
�E��j��t♦1V1t.
,
�tt
Ili
c,: � IL,llli.`1����
' 111 ._
0 V R A I
7
v - - - EMPORA
ACCESS — —
d - INTENANCE
�,4SE-MENT - 149' 1 0'
STORMWATER CONTROL AND MANAGEMENT
IMPERVIOUS CALCULATIONS - -
MAXIMUM IMPERVIOUS AREA SQUARE FOOTAGE ON EACH INDIVIDUAL LOT WILL
BE STRINGENTLY ENFORCED WITH NO EXCEPTIONS INTO PERPETUITY. PLANS
APPROVED WITH A MAXIMUM IMPERVIOUS SURFACE OF 7 000 SF PER LOT.
WAKE COUNTY TOOL V2.2 WAS USED FOR ALL STORMWATER CALCULATIONS. -0
NOTE: -
BEFORE ACQUIRING A BUILDING PERMIT FOR LOTS MARKED WITH AN THE BUILDER • - '
MAY NEED TO OBTAIN A FLOOD HAZARD AREA USE PERMIT FROM WAKE COUNTY -
ENVIRONMENTAL SERVICES.THE BUILDER'S ENGINEER, ARCHITECT AND/OR SURVEYOR PH A
(AS APPROPRIATE) MUST CERTIFY THAT ALL FLOOD HAZARD REQUIREMENTS ARE MET. '
THERE SHALL BE NO FILLING OR THE ERECTION OF PERMANENT STRUCTURES IN THE 0 10 zoo - 480
AREAS OF WAKE COUNTY FLOOD HAZARD SOILS OR FEDERAL EMERGENCY MANAGEMENT
AGENCY (FEMA) 100 YEAR FLOOD ZONES UNTIL A FLOOD STUDY IS APPROVED BY
WAKE COUNTY AND/OR F.E.M.A. — — — — _
( IN FEET )
1 inch = 100 ft.
1
29 0
14 S.F. 2
=7, SF. 60
43.1,
[•?
FILL
a
y,4=7,0 o SF. N F
II CA OL A T S
0 A Tf
0 I
� I
0' P R-
B DIN S A
,
1
II
0
50' RIGHT OF WAY
8' 20PAVEMENT 6'
CL
10' 10,
2" S9.513
PER FT.
8" CABC
RESIDENTIAL STREETS
TYPICAL CROSS SECTION
NTS
I I
PROTECTION ZONE' �
Q
J
I
�
I
3 ,6
�
��N
N�00
LLJ
Cw
, U
00
H
•U1
LL Q Q
I
AS
M NT
p
L- IL
L
10
l O
:2 L-J
39.4'
1
1
N
- L
19 F.
1
I I
I
7,0 0 S
Q
I
3 0.64
I
�L,31A 4 S.F.
�� MIA ,000
11 --s � •r •
AYE 1
CUT
2j
V C N TY M A P
SITE DATA - TOTAL
- SUBDIVISION # PLG-001688-2019
- TOTAL TRACT SIZE = 53.80 AC.
- TOTAL NO. LOTS ALLOWED = 53.8 = 78 LOTS
- TOTAL OPEN SPACE REQUIRED (10%) = 5.38 AC.
- TOTAL OPEN SPACE PROVIDED = 19.18 AC.
- TOTAL NO. LOTS = 35
- AVERAGE LOT SIZE = 0.90 AC. (39,005 S.F.)
- LINEAR FEET OF STREET = 2,843 LF
- IMPERVIOUS IN STREET = 1.46 AC. (63,598 S.F.)
- IMPERVIOUS IN LOTS = 5.62 AC. (244,807 S.F.)
- IMPERVIOUS IN KIOSK = 0.02 AC. (870 S.F.)
- IMPERVIOUS IN WELL 1 & 2 = 0.23 AC. (10,020 S.F.)
- TOTAL IMPERVIOUS = 7.33 AC. (319,295 S.F.)
- AREA OF STREETS = 3.28 AC.
- PIN # 0637-71-3720
- MINIMUM LOT SIZE = 12,000 S.F.
- MINIMUM LOT WIDTH = 60'
- ZONED R-30
- TOTAL DISTURBED AREA = 8.0 AC.
- % IMPERVIOUS = 14
- SETBACKS = FRONT = 15'
SIDE = 5'
REAR = 15'
CORNER = 15'
Model 1570 (F) CBU
1 6-Box Unit
1
DEVELOPER
SANFORD BAILEY
8900 BUD SMITH ROAD
WAKE FOREST, N.C. 27587
RIGHT OF WAY
EDGE OF TRAVEL LANE
R
R
ROADWAY CENTERLINE
EDGE OF TRAVEL LANE
RIGHF OF WAY
7"'
PAVED TURNOUT
TO CBU PAVEMENT STRUCTURE
20' 25' 20' �O MATCH TRAVEL LANES)
MIN. MIN. MIN. CONCRETE PAD
FOR CBU (PER USPS)
CBU (ACCESS FROM PAD)
5 7'
TURNOUT 2'
CBU
0
0
02� 0�
CONCRETE PAD
FOR CBU
NOTE:
SEE FIGURE 1 PAGE 39, "NCDOT
SUBDIVISION ROADS MINIMUM CONSTRUCTION MAINTAIN RM/ OFFSET
AROUND CBU TURNOUT
STANDARDS JANUARY 2010" FOR LOCAL AND COLLECTOR ROAD DIMENSIONS.
FIGURE 1
CBU PLACEMENT FOR SHOULDER SECTION RESIDENTIAL LOCAL AND
COLLECTOR SUBDIVISION STREETS
NOTES:
— PRESENT LAND USE IS VACANT, WOODED AND FALLOW.
— STREETS WILL HAVE A 50' R/W.
— ALL RADII AT STREET INTERSECTIONS ARE 25'
— ALL STREETS WILL BE PUBLIC AND CONSTRUCTED TO NORTH CAROLINA
DEPARTMENT OF TRANSPORTATION STANDARDS
— WATER SYSTEM WILL BE INDIVIDUAL WATER SYSTEM.
— SEWER SYSTEM WILL CONSIST OF INDIVIDUAL SEPTIC SYSTEMS.
— ALL WAKE COUNTY EROSION CONTROL MEASURES WILL BE COMPLIED
WITH DURING CONSTRUCTION
— ALL FEDERAL FLOOD HAZARD REGULATIONS WILL BE COMPLIED WITH
DURING CONSTRUCTION
— ALL STATE AND LOCAL GOVERNMENT APPROVALS SHALL BE SUBMITTED
TO THE SUBDIVISION OFFICE BEFORE FINAL PLAT APPROVAL
— DRAINAGE EASEMENTS SHALL BE PROVIDED FOR ALL AREAS
DRAINING 4 ACRES OR 4 LOTS AND SHALL BE SHOWN ON THE
CONSTRUCTION DRAWINGS AND ON THE FINAL PLAT, AFTER
SUCH AREAS CAN BE DETERMINED AND HAVE BEEN FIELD VERIFIED
— BOUNDARY INFORMATION SURVEYED BY CAWTHORNE, MOSS & PANCIERA, P.C.
— THE HOMEOWNERS ASSOCIATION WILL BE RESPONSIBLE FOR MAINTENANCE
OF THE OPEN SPACES IN THIS DEVELOPMENT.
— PROTECTED TREES TO BE LOCATED AT TIME OF CONSTRUCTION PLANS AND
AVOIDED OR REPLACED PER WAKE COUNTY UDO.
— NITROGEN REDUCTION CALCULATIONS WILL BE APPROVED AND BUYDOWN
RECEIPT OBTAINED PRIOR TO CONSTRUCTION.
— OPEN SPACE TO BE DEEDED TO HOMEOWNERS ASSOCIATION.
— PROPERTY IS LOCATED IN THE PANTHER BRANCH WATERSHED.
— ROADS AND INTERSECTIONS TO COMPLY WITH ALL NCDOT REQUIREMENTS.
wopo
NNN
I I
N 001,0
N N
I.-
H
LZLI I-- W
Z :2 Lu :2
OO:2O
NUgU
>> p
LLJ O O p
LLI O W
0
� of
Ofa_of
Ld LJ-1
OZ NIA
SEAL:
CAR /
/''%
=: �O .••LESS/� .?y
Q� "(� • ;
z SEAL
- 22024
I 111,E 23-202CL
cc
OI
O0 (\
\\ r ^ C)
z s�
�Luo�
cj�
z Q�
cir
LLJ
z_ ct��
z
w
O
t
W
r-
DO
p
ON
W
U
�FZ
ck:I
O QNN
N
w
z
Z
o
Q w
w
m
m�LLJ
Of
N
LLJ
U
LLJ
U Q
U
a vQiw3
tE
o
N
Y
a
LLJ
SE 0-
a
z
O
U/
U
z
z
Q
O
O
W
Z
LL
°
}
Z
C/)
U
z
O
zw
U)w
>
W
Q
i
m
J
Z
cU
0.
U)
Q
O
U
M�
W
V—V
- SUBDIVISION # PLG-001688-2019