Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SWA000073_JFHQ Raleigh Helipad_20200721
© 2018 Microsoft Corporation © 2018 HERE JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.5410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICEN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E R 0 3 3 6 1 2N O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E R S E A LN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RF R A N C I S S L I N S K Y, I I I24 JULY 2020 NORTH CAROLINA NATIONAL GUARD JFHQ RALEIGH HELIPAD1636 GOLD STAR DRIVE, SUITE 2600, RALEIGH, NORTH CAROLINA 27607 | NCSCO CASE #: 17-16713-01A42866 WA FS FS NTS NORTH CAROLINA LICENSE NO. C-16526/24/20 STORMWATER FAST TRACK ATC SUBMITTAL06/24/2020CS0.0 COVER SHEETINDEX OF DRAWINGS C1.0 C3.0 EXISTING CONDITIONS & DEMOLITION PLAN SCHEDULE OF MATERIAL TESTING SERVICES MATERIAL TESTING BY THIRD PARTY Verification of Soils Excavation and Fill Piling and Drilling Piers Modular Retaining Walls Reinforced Concrete Post Tension Slab Pre-cast Concrete Erection Pre-stressed Concrete Inspection of Pre-cast Fabricators Structural Masonry Inpection of Structural Steel Fabricators Welding High Strength Bolts and Steel Framing Insp. Sprayed Fire-Resistance Materials Exterior Insulation and Finish System Seismic Resistance Smoke Control Detention Basin Asphalt Pavement Cores and Density Tests The following sheets comprise the required schedule of material testing services in this project. The construction items to be inspected are as follows: No special inspections required for this project STAKING PLAN C5.0 EROSION & SEDIMENT CONTROL NOTES & DETAILS C5.1 SITE C5.2 C5.3 C5.4 SITE NOTES & DETAILS C3.5 GRADING & DRAINAGE PLAN C2.0 EROSION & SEDIMENT CONTROL PLAN PHASE I NORTH CAROLINA NATIONAL GUARD JFHQ RALEIGH HELIPAD 1636 GOLD STAR DRIVE, SUITE 2600, RALEIGH, NORTH CAROLINA 27607 NCSCO CASE #: 17-16713-01A STORMWATER SUBMITTAL PROJECT TEAM CONTACT: MR. JOSEPH SHELL DELTA AIRPORT CONSULTANTS AVIATION CONSULTANT & ELECTRICAL ENGINEER PHONE: (804) 218-9676 1750 E. INTERNATIONAL DRIVE, SUITE 3 RALEIGH, NC 27623 CIVIL ENGINEER TIMMONS GROUP RALEIGH, NC 27607 5410 TRINITY ROAD, SUITE 102 CONTACT: MR. FRANK SLINSKY PHONE: (919) 866-4505 VICINITY MAP 1"=1000' OWNER CONTACT: MR. ROBERT BRYANT NORTH CAROLINA NATIONAL GUARD OWNER PHONE: (919) 664-6116 1636 GOLD STAR DRIVE, SUITE 2600 RALEIGH, NC 27607 C2.1 EROSION & SEDIMENT CONTROL PLAN PHASE II C3.1 GEOMETRIC LAYOUT (BASE BID) C3.3 PCC JOINT LAYOUT (BASE BID) MARKING LAYOUT C4.0 C5.5 SITE NOTES & DETAILS C5.6 SITE NOTES & DETAILS C5.7 BIORETENTION NOTES & DETAILS C6.0 JOINT DETAILS C6.1 JOINT DETAILS C6.2 JOINT DETAILS C6.3 JOINT DETAILS C6.4 JOINT DETAILS C7.0 MARKING DETAILS C7.1 AIRCRAFT MOORING DETAILS E1.0 ELECTRICAL NOTES E1.1 ELECTRICAL NOTES E2.0 SITE ELECTRICAL PLAN (BASE BID) E2.2 BUILDING ELECTRICAL PLAN E3.0 BUILDING SECTION E4.0 ELECTRICAL DETAILS E4.1 ELECTRICAL DETAILS E4.2 ELECTRICAL DETAILS E4.3 ELECTRICAL DETAILS E4.4 ELECTRICAL DETAILS E4.5 ELECTRICAL DETAILS E4.6 ELECTRICAL DETAILS E4.7 ELECTRICAL DETAILS E4.8 ELECTRICAL DETAILS E4.9 ELECTRICAL DETAILS (ALTERNATE 4) E4.10 ELECTRICAL DETAILS SITE CIVIL ELECTRICAL EROSION & SEDIMENT CONTROL NOTES & DETAILS EROSION & SEDIMENT CONTROL NOTES & DETAILS EROSION & SEDIMENT CONTROL NOTES & DETAILS C5.8 CABLE BARRIER NOTES & DETAILS CS0.0 COVER SHEET GENERAL C3.4 PCC JOINT LAYOUT (ALTERNATE 1) C3.2 GEOMETRIC LAYOUT (ALTERNATE 1) E2.1 SITE ELECTRICAL PLAN (ALTERNATE 2, 3, & 4) SHEETS INCLUDED IN STORMWATER SUBMITTAL C4.1 STORMWATER MANAGEMENT PLAN 425 430 435 440 445 445421422 423 424 426 427 428 429 431 432 433 434 436 437 438 439 441 442 443 4444204254304354174184194214224 2 3 424426427428429431432433434436 437 438 400 405 410 415 420 396 397398399 401 402 403 404 406407408 409 411412413414 416 417 418 419 421 410 415 420 425 406407408409 411 412 413 414 416417418419 421 422 423 424 426 427 428 429 4 3 0 4 3 5 440 445 4274284 2 9 4 3 1 4 3 2 4 3 3 4 3 4 4 3 6 4 3 7 4 3 8 4 3 9 4 4 1 4 4 2 443 444 4464474484404454504414424434444464474484494514254304354404264274 2 8 429431432433434436437438439441442443444 4 0 0 40541 039739 8 3 9 9 4 0 1 4 0 2 4 0 3 40440640 7 40 8 40 9 41 1 4 0 0 4054104154204254304354404454504 0 1 4 0 2 4034044 0 6 4 0 7 4 0 8 4 0 9 411412413414416417418419421422423424426427428429431432433434436437438439441442443444446447448449451390 3 9 5 400 390390390395393392391390389388393395397396395396398397399 395395396 398 39839639539439 1 3 9 1 3 9 3 392391392390 392400 405 410 394 390 389 387 386387390398396 394 400 396403410415395400405 400 425 427 4324 3 0 42242 0 41 7 41 0 43 4391392XXXXX OHP LOCALIZATION POINT NC GRID (NAD 83/NSRS2007) N=748569.73' E=2085686.64' NAVD '88 ELEV. = 448.83' COMBINED FACTOR = 0.999902990 (SEE NOTE NO. 6) CONTROL POINT (REBAR & CAP) G G G G G G G G G G G G G G G G UGT UCATV UCATV UCATV UCATV UCATV UFO UFO UFO UFO UFO UCATV UCATV UFO UFO UGP UGP UGP UGP UGP UGP UGP UGP UGP UGP UGP UGP UGP UGP UCATV UCATV UCATV UCATV UCATV UFO UFO UFO UFO UFO EXISTING CREEKEXISTING CREEKGOLDSTAR DRIVE 15" RCP15" RCP INV. = 381.4' INV. = 381.4' INV. = 381.4' (3) 60" RCP SANSANASPHALTS 76° 2 3 ' 0 4 " E 2 8 9 . 0 9 ' S 78°50' 5 4 " E 6 9 4 . 1 4 ' S 82°03'46" E 1 6 1 . 5 7 'ASPHALTEXISTING 70' PROGRESS ENERGY TRANSMISSION LINE EASEMENT D.B. 12818, PG. 189 S 03°07'12" E 69.77' (TIE) WOODS INV. = 385.3' INV. = 385.3'SANINV. = 385.3'S 06°39'34" E 425.85' (TOTAL)N 13°59'31" E 554.14'N 86°00'28" W 1279.26 ' ( T O T A L ) 35.90' X X XXX X X X X X X X X X X X X TBM-BENCHTIE IN 8" PINE NAVD '88 ELEV. = 442.57'OHPOHPOHPOHPOHPOHPOHPOHP145.03' (TI E ) X X X X X X X X X X X X X X XXX N 54°31'43" W 57.83' 1221.43'288.01'137.84'C1 C2 XX X XXGGGWWWWWWW W EXISTING 10' PSNC ENERGY GAS LINE EASEMENT D.B. 14410, PG. 1992 INV = 431.4' INV = 428.5' GATEASPHALTGRAVEL ASPHALT EXISTING F/O VAULT 18" RCP EXISTING CATV VAULTP/LEXISTING 70' PROGRESS ENERGY TRANSMISSION LINE EASEMENT D.B. 12818, PG. 18930' ZONE 1 RIPARIAN BUFFERN 6 0 ° 2 3 ' 4 2 "W 4 0 3 . 9 8 ' PRO PO S ED PRO P ER T Y L IN E BRUSH / SPARSE WOODS BRUSH / SPARSE WOODS50' ZONE 2 RIPARIAN BUFFEREXISTING RIP RAP DITCH EXISTING SEWER MANHOLE RIM = 394.3' INV IN (S) = 387.1' INV OUT (N) = 385.3' EXISTING SEWER MANHOLE RIM = 397.1' INV IN (S) = 389.8' INV OUT (N) = 389.7' WOODS WOODS WOODS WOODS WOODS EXISTING WATER VAULT EXISTING SEWER LINE IS SUBJECT TO ANY PUBLIC RECORDS FOR AN EASEMENT CONVEYANCE THAT WAS NOT FOUND BY SEARCHING THE WAKE COUNTY REGISTER OF DEEDS. EXISTING SEWER LINE RUNS THROUGH BOX CULVERT DISTRICT DRIVE - SR 1 7 7 4 (60' R/W) WADE A V E N U E E X T E N S I O N (VARIA B L E W I D T H R / W )APPROXIMATE LOCATION OF R/W (NOT SURVEYED)(PLOTTED FROM NCDOTPROJECT NO. 9.9050653 - SHEET 4)WOODS NCD O T R / W NCDOT R /W EXISTING DROP INLET GRATE = 451.5' INV IN (E) = 449.2' INV IN (S) = 449.3' INV OUT (W) = 443.6' EXISTING DROP INLET GRATE = 451.4' INV OUT (W) = 447.6' 18" RC P INV.= 445.6' 15" RCP INV.= 438.9' EXISTING SEWER MANHOLE RIM = 401.9' INV IN (S) = 383.4' INV OUT (N) = 383.4' EXISTING CONC. HEADWALL 6' BOX CULVERT TOP OF HEADWALL = 399.1' INVERT OUT = 390.8' EXISTING 6' BOX CULVERT EXISTING CONC. HEADWALL TOP OF HEADWALL = 392.1' EXISTING CONC. HEADWALL TBM-TOP OF BOLT NAVD '88 ELEV. = 448.58' TBM-BENCHTIE IN 18" POPLAR NAVD '88 ELEV. = 393.34' TBM-BENCHTIE IN 12" PINE NAVD '88 ELEV. = 398.91' EX I S T I N G R I P R A P D I T C H NCDOT R / W TREE CLEARING IN R/W ALLOWED BY NCDOT TREE CLEARING IN R/W ALLOWED BY NCDOT A - A - A - B - B - B - C - C - C - SURPLUS R/W GRANTED BY NCDOT IN STATE PROJECT 8.2402801 R/W FA PROJECT STP-3009(1) DEMOLISH EXISTING FENCE CONSTRU C T I O N L I M I T SCONSTRUCTION LIMITSCONSTRUCTION LIMIT S CONSTRUCTION LIMITSTEMPORARY BENCH MARK POWER POLE SIGN EXISTING RIGHT-OF-WAY PROPERTY LINE (NOT SURVEYED)CONTROL POINT (REBAR & CAP) EXISTING IRON PIPE, STAKE, REBAR SPOT ELEVATION P/L OVERHEAD ELECTRIC/POWER UNDERGROUND TELEPHONE OHP T X EXISTING FENCECOMPUTED POINT (NO POINT SET) EXISTING NAIL NEAR FENCE CORNER EXISTING SANITARY SEWER MANHOLE EXISTING UNDERGROUND NATURAL GAS LINE EXISTING UNDERGROUND ELECTRIC LINE EXISTING UNDERGROUND CATV EXISTING UNDERGROUND TV FIBER OPTIC LINE EXISTING WOOD LINE G UGP UCATV UFO SAN EXISTING UNDERGROUND SANITARY SEWER LINE EXISTING CONCRETE RW MONUMENT EXISTING TELEPHONE MANHOLE EXISTING GUARD RAIL EXISTING U/G VAULT EXISTING CATV PEDESTAL EXISTING U/G GAS VALVE EXISTING WATER VALVE EXISTING UNDERGROUND WATER LINEW EXISTING BOLLARD EXISTING CONDITIONS LEGEND KEY NOTES 1.ALL EXISTING STRUCTURES AND UTILITIES SHALL BE REMOVED AS NEEDED TO ALLOW NEW CONSTRUCTION. IN GENERAL, FEATURES INDICATED IN BOLD ON THIS PLAN SHALL BE REMOVED. UNDERGROUND ELECTRICAL LINES MAY BE ABANDONED IN PLACE OUTSIDE OF NEW BUILDING LIMITS. COORDINATE PROPER ABANDONMENT WITH UTILITY COMPANY. 2.ANY EXISTING PAVEMENT, ETC. THAT MUST BE REMOVED TO ALLOW NEW CONSTRUCTION SHALL BE REMOVED AND REPAIRED PER THE SPECIFICATIONS AND DETAILS OR TO MATCH PRE-CONSTRUCTION CONDITIONS (WHETHER OR NOT SHOWN ON THE DRAWINGS TO BE REMOVED). 3.ALL UTILITIES OR STRUCTURES NOT INDICATED FOR REMOVAL OR MODIFICATION ARE TO REMAIN AND BE PROTECTED FROM DAMAGE. 4.ALL WASTE MATERIAL GENERATED FROM DEMOLITION ACTIVITIES SHALL BE DISPOSED OF OFF-SITE IN ACCORDANCE WITH ALL APPLICABLE RULES AND REGULATIONS AND RECYCLED TO THE GREATEST EXTENT POSSIBLE. 5.THESE PLANS DO NOT ASSUME ANY LIABILITY FOR ANY EXISTING INFORMATION BOTH SHOWN AND NOT SHOWN ON THE SURVEY AND ANY CHANGES TO THE EXISTING CONDITIONS THAT MAY HAVE OCCURRED AFTER THE SURVEY WAS ISSUED. CONTRACTOR SHALL VERIFY ALL EXISTING SITE CONDITIONS PRIOR TO CONSTRUCTION. 6.INSTALL SAFETY FENCE PRIOR TO BEGINNING OF CONSTRUCTION PER SPECIFICATIONS AND DRAWINGS. ALL CONTRACTORS SHALL VISIT THE SITE AND OBSERVE EXISTING CONDITIONS PRIOR TO BIDDING. 7.PRIOR TO DEMOLISHING EXISTING STRUCTURES, MAKE AN INSPECTION FOR ANY HAZARDOUS MATERIALS. CONTACT ENGINEER IMMEDIATELY IF ANY HAZARDOUS MATERIALS ARE DISCOVERED. ALL WORK TO BE PERFORMED IN ACCORDANCE WITH APPLICABLE FEDERAL, STATE AND LOCAL REGULATIONS. 8.VERIFY ALL ILLUSTRATED KNOWN UNDERGROUND ELEMENTS. EXERCISE REASONABLE EFFORTS TO PROTECT ANY UNKNOWN UNDERGROUND ELEMENTS. NOTIFY THE ENGINEER IMMEDIATELY IF UNKNOWN ELEMENTS ARE DISCOVERED THAT WOULD NECESSITATE MODIFICATION TO THE PROPOSED DESIGN. 9.PROTECT ALL ADJACENT PROPERTIES, THE GENERAL PUBLIC AND ALL OF THE OWNER'S FACILITIES. SHOULD DAMAGES OCCUR, REPAIR IMMEDIATELY AS DIRECTED BY THE ENGINEER. 10.ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH APPLICABLE LOCAL, STATE AND OSHA REGULATIONS. 11.ALL EXISTING VAULTS, MANHOLES, STORM DRAIN STRUCTURES, CLEANOUTS, ETC. SHALL BE ADJUSTED AS NEEDED TO MATCH FINISH GRADE. 12.ALL CONSTRUCTION SHALL BE IN STRICT ACCORDANCE WITH NC STATE CONSTRUCTION STANDARDS, SPECIFICATIONS, AND DETAILS. 13.DEMOLITION AND PATCHING OF PAVEMENT AND OTHER EXISTING PAVED SURFACES IN ADDITION TO THAT INDICATED ON THIS PLAN SHALL BE PERFORMED AS REQUIRED TO CONSTRUCT AND INSTALL NEW UTILITIES. ALL SUCH DEMOLITION AND PATCHING SHALL BE INCLUDED IN THE BASE BID SCOPE OF WORK. DEMOLITION NOTES REMOVE EXISTING TREES BRUSH/SPARSE TREE CLEARING REMOVE R/W FENCE A - B - C - JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.5410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICEN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E R 0 3 3 6 1 2N O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E R S E A LN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RF R A N C I S S L I N S K Y, I I I24 JULY 2020 NORTH CAROLINA NATIONAL GUARD JFHQ RALEIGH HELIPAD1636 GOLD STAR DRIVE, SUITE 2600, RALEIGH, NORTH CAROLINA 27607 | NCSCO CASE #: 17-16713-01A42866 WA FS FS NTS NORTH CAROLINA LICENSE NO. C-16526/24/20 STORMWATER FAST TRACK ATC SUBMITTAL06/24/2020C1.0 EXISTING CONDITIONS & DEMOLITION PLANNAD 83SCALE 1"=50' 100'50'0 XXXXXOHP LOCALIZATION POINT NC GRID (NAD 83/NSRS2007) N=748569.73' E=2085686.64' NAVD '88 ELEV. = 448.83' COMBINED FACTOR = 0.999902990 (SEE NOTE NO. 6) CONTROL POINT (REBAR & CAP) G G G G G G G G G G G G G G G G UGT UCATV UCATV UCATV UCATV UCATV UFO UFO UFO UFO UFO UCATV UCATV UFO UFO UGP UGP UGP UGP UGP UGP UGP UGP UGP UGP UGP UGP UGP UGP UCATV UCATV UCATV UCATV UCATV UFO UFO UFO UFO UFOGOLDSTAR DRIVE SANSANS 76° 2 3 ' 0 4 " E 2 8 9 . 0 9 ' S 78°50' 5 4 " E 6 9 4 . 1 4 ' S 82°03'46" E 1 6 1 . 5 7 ' S 03°07'12" E 69.77' (TIE)SANS 06°39'34" E 425.85' (TOTAL)N 13°59'31" E 554.14'N 86°00'28" W 1279.26 ' ( T O T A L ) 35.90' OWNER INFORMATION PIN NO. 0785316741 STATE OF NORTH CAROLINA B.M. 1985, PG. 1399 B.M. 1988, PG. 1339 B.M. 2011, PG. 451 X X XXX X X X X X X X X X TBM-BENCHTIE IN 8" PINE NAVD '88 ELEV. = 442.57'OHPOHPOHPOHPOHPOHPOHPOHP145.03' (TI E )XXN 54°31'43" W 57.83' 1221.43'288.01'137.84'C1 C2 XX X XXGGGWWWWWWW W OWNER INFORMATION PIN NO. 0785316741 STATE OF NORTH CAROLINA B.M. 1985, PG. 1399 B.M. 1988, PG. 1339 B.M. 2011, PG. 451 OWNER INFORMATION PIN NO. 0785316741 STATE OF NORTH CAROLINA B.M. 1985, PG. 1399 B.M. 1988, PG. 1339 B.M. 2011, PG. 451 P/L30' ZONE 1 RIPARIAN BUFFERN 6 0 ° 2 3 ' 4 2 "W 4 0 3 . 9 8 ' PRO PO S ED PRO P ER T Y L IN E50' ZONE 2 RIPARIAN BUFFERDISTRICT DRIVE - SR 1 7 7 4 (60' R/W) WADE A V E N U E E X T E N S I O N (VARIA B L E W I D T H R / W )APPROXIMATE LOCATION OF R/W (NOT SURVEYED)(PLOTTED FROM NCDOTPROJECT NO. 9.9050653 - SHEET 4)NCD O T R / W NCDOT R /W TBM-TOP OF BOLT NAVD '88 ELEV. = 448.58' TBM-BENCHTIE IN 18" POPLAR NAVD '88 ELEV. = 393.34' TBM-BENCHTIE IN 12" PINE NAVD '88 ELEV. = 398.91' NCDOT R / W 2 C5.5 50'100' 42.5' 127.5' 42.5'35' 100' 283' 25' 233' 25' 212.5' R35' 150' 25' 25' 25' 50' X X X X X X X X X XXXX X X X X X X X X X X XXXXXXX R35' 50' 50' 50' 50' 50' 50' 10' 10' EDGE OF GRASS SHOU L D E R EDGE OF GRASS SHOULDEREDGE OF GRASS SHOU L D E R 50' 10' X X X X X X X X X X X X X X X NCDOT R/W FENCING TO MATCH EXISTING 2 C5.5XXX X X X 5 C5.6 R35'EDGE OF GRASS SHOULDEREDGE OF GRASS SHOULDERREFER TO SHEETS C3.1 & C3.2 FOR GEOMETRIC LAYOUT OF HELIPAD AND SHEET C6.0 FOR PAVEMENT SECTIONS 5 C5.6 1 C5.4 1 C5.8 2 C5.5 2 C5.5 N: 748446.26 E: 2085367.30 N: 748442.14 E: 2085426.52 N: 748556.59 E: 2085374.48 N: 748550.30 E: 2085468.37 24' 1 C5.4 1 C5.4 1 C5.5 1 C5.4 1 C5.4 1 C5.4 1 C5.4 1 C5.4 1 C5.5 1 C5.4 1 C5.8 1 C5.4 N: 748517.33 E: 2085431.00 N: 748519.53 E: 2085407.09 N: 748479.09 E: 2085404.68 50' 39' 37.5' 52' 37.5' 52' 50' 39' GENERAL NOTES: 1.COMPLY WITH ALL APPLICABLE NCSCO AND OSHA STANDARDS. 3.RECYCLE ALL PAVING MATERIALS REMOVED FROM THE SITE AND SHALL PROVIDE DOCUMENTATION (SWARWEB) THAT THE MATERIALS HAVE BEEN RECYCLED. 4.DISPOSE OF OFF-SITE WASTE MATERIALS GENERATED DURING CONSTRUCTION. OBTAIN ALL APPLICABLE PERMITS FOR OFF-SITE STOCKPILES AND/OR WASTE AREAS. 5.CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGES DURING CONSTRUCTION AND SHALL MAKE REPAIRS AT NO EXPENSE TO THE OWNER. GENERAL PAVING NOTES: 1.RAISE ALL STRUCTURES WITHIN THE AREAS TO BE OVERLAID SUCH THAT THE TOP OF THE STRUCTURE EQUALS THE FINISH GRADE OF THE NEW ASPHALT. 2.COORDINATE THE PROJECT SCHEDULE WITH THE CIVIL ENGINEER AND THE OWNER. KEY NOTES ASPHALT PAVEMENT (REFER TO SHEET C6.0) BLACK VINYL CHAINLINK FENCE WITH ALL BLACK MATERIALS AND CONCRETE MOW STRIP (8' TOTAL HEIGHT) MODULAR BLOCK RETAINING WALL 1 C5.4 5 C5.6 PVC COATED CHAINLINK GATES WITH BARBED WIRE (8' HEIGHT) 1 C5.5 NOTES WOVEN WIRED FENCE 2 C5.5 CABLE BARRIER1 C5.8 PORTLAND CEMENT CONCRETE (PCC) PAVEMENT (REFER TO SHEETS C3.1, C3.2, AND C6.0 - C6.4) BASE BID: ASPHALT PAVEMENT ALTERNATE 5: PORTLAND CONCRETE CEMENT (PCC) PAVEMENT IN LIEU OF ASPHALT PAVEMENT JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.5410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICEN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E R 0 3 3 6 1 2N O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E R S E A LN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RF R A N C I S S L I N S K Y, I I I24 JULY 2020 NORTH CAROLINA NATIONAL GUARD JFHQ RALEIGH HELIPAD1636 GOLD STAR DRIVE, SUITE 2600, RALEIGH, NORTH CAROLINA 27607 | NCSCO CASE #: 17-16713-01A42866 WA FS FS NTS NORTH CAROLINA LICENSE NO. C-16526/24/20 STORMWATER FAST TRACK ATC SUBMITTAL06/24/2020STAKING PLANNAD 83SCALE 1"=50' 100'50'0 C3.0 KEY NOTES BIORETENTION STORMWATER CONTROL MEASURE FLARED END SECTION DRAINAGE MANHOLE STANDARD CONCRETE DROP INLET NOTES 1.ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE NCSCO AND OSHA STANDARDS. 2.THE CONTRACTOR SHALL RECYCLE MATERIALS REMOVED FROM THE SITE AND SHALL PROVIDE DOCUMENTATION (SWAR) THAT THE MATERIALS HAVE BEEN RECYCLED. 3.DISPOSE OFF-SITE WASTE MATERIALS GENERATED DURING CONSTRUCTION AND FOR OBTAINING ALL APPLICABLE PERMITS FOR OFF-SITE STOCKPILES AND/OR WASTE AREAS. IF THE SAME PERSON CONDUCTS THE LAND-DISTURBING ACTIVITY AND ANY RELATED BORROW OR WASTE ACTIVITY, THE RELATED BORROW OR WASTE ACTIVITY IS PART OF THE LAND DISTURBING ACTIVITY. IF THE BORROW OR WASTE ACTIVITY ARE NOT CONDUCTED BY THE SAME PERSON, THEY SHALL BE CONSIDERED SEPARATE LAND DISTURBING ACTIVITY AND MUST BE PERMITTED THROUGH THE SEDIMENT POLLUTION CONTROL ACT. 4.REPAIR OR REPLACE ANY ITEMS DAMAGED DUE TO CONSTRUCTION (ONSITE AND/OR OFFSITE) AT NO EXPENSE TO THE OWNER. 5.COORDINATE THE PROJECT SCHEDULE WITH THE OWNER, OWNER'S CIVIL ENGINEER, AND OWNER'S MATERIAL TESTING AGENT. COORDINATE THE PROJECT SCHEDULE WITH ALL PARTIES IN ACCORDANCE WITH THE OWNER'S ONGOING ONSITE OPERATIONS. 6.ALL STORM DRAINAGE PIPES AND STRUCTURES SHALL BE THOROUGHLY FLUSHED OF ALL SEDIMENT FOLLOWING SITE STABILIZATION. INTERIOR FLUSHING OF SYSTEM SHALL BE PERFORMED AS NEEDED TO MAINTAIN PROPER FUNCTIONING OF THE DRAINAGE SYSTEM. 7.MAINTAIN ALL EROSION CONTROL DEVICES AFTER EACH RAINFALL EVENT IN ACCORDANCE WITH NCDEQ LAND QUALITY REQUIREMENTS AND AS DIRECTED BY THE CIVIL ENGINEER. 8.IN DISTURBED AREAS, AMEND THE TOP 6 INCHES OF LAWN AREAS WITH 3 INCHES OF IMPORTED AND TESTED TOPSOIL THAT MEET THE SPECIFICATIONS. 9.ALL SIDEWALKS SHALL HAVE MAX CROSS SLOPE OF 2%. 10.ALL ADA PARKING SPACES SHALL NOT EXCEED 2% SLOPE IN ANY DIRECTION. 11.INSTALL ALL STORM SEWERS TO PROVIDE REQUIRED CLEARANCES TO CROSSING UTILITIES AS INDICATED IN THE DRAWINGS AND SPECIFICATIONS. 12.PROVIDE AN AS-BUILT SURVEY OF ALL UTILITY AND STORM 13.PHASE DEMOLITION AND NEW CONSTRUCTION TO ENSURE UNINTERRUPTED ACCESS AND TO ADJACENT FACILITIES. COORDINATE SHORT-TERM, OFF-HOUR, TEMPORARY SHUT- DOWNS WITH THE OWNER. 14.SEE GENERAL NOTES ON EXISTING CONDITIONS AND DEMOLITION PLAN FOR REQUIREMENTS FOR REMOVAL AND PATCHING OF PAVEMENT FOR UTILITY INSTALLATION. 15.REFER TO PROJECT SPECIFICATIONS FOR ADDITIONAL INFORMATION. T-1: 9 FEET OF UNSTRUCTURED FILL T-2: 8.5 FEET OF UNSTRUCTURED FILL T-3: 6 FEET OF UNSTRUCTURED FILL T-4: 6 FEET OF UNSTRUCTURED FILL T-5: 6.5 FEET OF UNSTRUCTURED FILL T-6: 9 FEET OF UNSTRUCTURED FILL T-7: 8 FEET OF UNSTRUCTURED FILL T-8: NO FILL (NATIVE SOILS) T-9: NO FILL (NATIVE SOILS) TEST PIT BORING DATA RIP RAP OUTLET PROTECTION MODULAR BLOCK RETAINING WALL AREA OF UNSUITABLE (FILL) MATERIAL (PLACE IN GRASS AREAS) CONCRETE UTILITY CRADLE TRENCH DRAIN YARD DRAIN REINFORCED CONCRETE STORM PIPE HDPE STORM PIPE D STANDARD STORM SEWER CLEANOUT 1 C5.6 2 C5.6 4 C5.6 1 C5.7 3 C5.1 2 C5.5 3 C5.9 2 C5.9 1 C5.9 4 C5.9 SOD BIORETENTION CELL WITH CELEBRATION BERMUDA 425 430 435 440 445 445421422 423 424 426 427 428 429 431 432 433 434 436 437 438 439 441 442 443 4444204254304354174184194214224 2 3 424426427428429431432433434436 437 438 400 405 410 415 420 396 397398399 401 402 403 404 406 407408 409 411412413414 416 417 418 419 421 410 415 420 425 406407408409 411 412 413 414 416417418419 421 422 423 424 426 427 428 429 4 3 0 4 3 5 440 4454274284 2 9 4 3 1 4 3 2 4 3 3 4 3 4 4 3 6 4 3 7 4 3 8 4 3 9 4 4 1 4 4 2443 4444464474484404454504414424434444464474484494514254304354404264274 2 8 429431432433434436437438439441442443444 4 0 0 40541 039739 8 3 9 9 4 0 1 4 0 2 4 0 3 40440640 7 40 8 40 9 41 1 4 0 0 4054104154204254304354404454504 0 1 4 0 2 4034044 0 6 4 0 7 4 0 8 4 0 9 411412413414416417418419421422423424426427428429431432433434436437438439441442443444446447448449451390 395 400 390390390395393392391390389388393395397396395396398397399 395395396 398 39839639539439 1 3 9 1 3 9 3 392391392390 392400 405 410 394 390 389 387 386387390398396394 400 396403410415395400405 400 425 427 4324 3 0 42242 0 41 7 41 0 43 4391392 X X X X X X X X X XXXX X X X X X X X X X X XXXXXXX X X X X X X X X X X X X X X X XXX X X XXXXXX OHP LOCALIZATION POINT NC GRID (NAD 83/NSRS2007) N=748569.73' E=2085686.64' NAVD '88 ELEV. = 448.83' COMBINED FACTOR = 0.999902990 (SEE NOTE NO. 6) CONTROL POINT (REBAR & CAP) G G G G G G G G G G G G G G G G UGT UCATV UCATV UCATV UCATV UCATV UFO UFO UFO UFO UFO UCATV UCATV UFO UFO UGP UGP UGP UGP UGP UGP UGP UGP UGP UGP UGP UGP UGP UGP UCATV UCATV UCATV UCATV UCATV UFO UFO UFO UFO UFOGOLDSTAR DRIVE SANSANS 76° 2 3 ' 0 4 " E 2 8 9 . 0 9 ' S 78°50' 5 4 " E 6 9 4 . 1 4 ' S 82°03'46" E 1 6 1 . 5 7 ' S 03°07'12" E 69.77' (TIE)SANS 06°39'34" E 425.85' (TOTAL)N 13°59'31" E 554.14'N 86°00'28" W 1279.2 6 ' ( T O T A L ) 35.90' X X XXX X X X X X X X X X TBM-BENCHTIE IN 8" PINE NAVD '88 ELEV. = 442.57'OHPOHPOHPOHPOHPOHPOHPOHP145.03' (TI E )XXN 54°31'43" W 57.83' 1221.43'288.01'137.84'C1 C2 XX X XXGGGWWWWWWW W P/L30' ZONE 1 RIPARIAN BUFFERN 6 0 ° 2 3 ' 4 2 "W 4 0 3 . 9 8 ' PRO PO S ED PRO P ER T Y L IN E50' ZONE 2 RIPARIAN BUFFERDISTRICT DRIVE - SR 1 7 7 4 (60' R/W) WADE A V E N U E E X T E N S I O N (VARIA B L E W I D T H R / W )APPROXIMATE LOCATION OF R/W (NOT SURVEYED)(PLOTTED FROM NCDOTPROJECT NO. 9.9050653 - SHEET 4)NCD O T R / W NCDOT R /W TBM-TOP OF BOLT NAVD '88 ELEV. = 448.58' TBM-BENCHTIE IN 18" POPLAR NAVD '88 ELEV. = 393.34' TBM-BENCHTIE IN 12" PINE NAVD '88 ELEV. = 398.91' NCDOT R / W -2.25%-3.07%-2.03%-3.20% -1.00%-2.88%-1.58%-1.93 % -2.83% -1.42 %-1.41%- 2 . 9 2%418427 42 0 42 3 441 438424424 433 435 423 425 425 428 430 434 4384 2 9 4 3 1 41 942042 4 4 1 1 436 443 442 4 3 4 437435434 418 414 409 406 421 416 410 430 418 414 417 42 5 441420 -1.43 % 424 420422 41 7 50' 50' 50' 50' 50' 50' 50' T-5 T-6 T-4 T-3 T-2 T-8 T-7 T-1 T-9 436435433431435437B-3 B-5 B-4 B-1 B-6 B-2 AREA OF UNSUITABLE FILL MATERIAL BURY IN GRASS AREA AS PART OF BASE BID. NO UNSUITABLE MATERIAL SHALL REMAIN UNDER PAVED SURFACES. D DD 4 3 0 4 3 1 42 7 42 8 42 9 42 6 42 7 42 8 42 9 42 6 42 7 42 8 42 9 4 3 0429425430426427428429431432 433BIORETENTION STORMWATER CONTROL MEASURE 42 9 . 2 429.2 4 C5.6 1 C5.6 4 C5.6 4 C5.6 2 C5.6 4 C5.6 1 C5.6 4 C5.6 2 C5.5 2 C5.6 1 C5.6 2 C5.5 3 C5.1 3 C5.1 3 C5.1 C1 C2C3 A5 A4 A2 4 C5.6 A3 1 C5.6 A1 B1 B2 B3 B5 4 C5.6B7 1 C5.6 B8 7 C5.6 TD-7 5 C5.6 Y1 6 C5.6 TD-7 6 C5.6 8" SOLID SMOOTH WALL HDPE INV IN: 426.69' HIGH-POINT 430.80' 3 C5.1 1 C5.7 5 C5.6 Y2 5 C5.6 Y3 E HIGH-POINT 435.25' 4 C5.9 4 C5.9 4 C5.9 A C B 425 427 430 422 X X X X X X X NCDOT R/W-3.07%429 431 T-3 D 430 431 427 428 429 426 427 428 429 426427428429 430 429428429BIORETENTION STORMWATER CONTROL MEASURE 9.6' 9.6' 9.6' 9.6' 9.6' 10' TOP OF BERM429.2 429. 2 TYP. OF 12 IN BIORETENTION 1 C5.7 3:1 SIDE SLOPES OUTLET STRUCTURE (C4) REFER TO DETAIL 3 C5.1E 1 C5.6 B8 6" PERFORATED UNDERDRAIN (TYP.) 8' RIPRAP LINED EMERGENCY SPILLWAY 3 C5.1 B 1 C5.6 B3 4 C5.9 SOD WITH CELEBRATION BERMUDA JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.5410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICEN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E R 0 3 3 6 1 2N O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E R S E A LN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RF R A N C I S S L I N S K Y, I I I24 JULY 2020 NORTH CAROLINA NATIONAL GUARD JFHQ RALEIGH HELIPAD1636 GOLD STAR DRIVE, SUITE 2600, RALEIGH, NORTH CAROLINA 27607 | NCSCO CASE #: 17-16713-01A42866 WA FS FS NTS NORTH CAROLINA LICENSE NO. C-16526/24/20 STORMWATER FAST TRACK ATC SUBMITTAL06/24/2020C4.0 GRADING & DRAINAGE PLANNAD 83SCALE 1"=50' 100'50'0 ABBREVIATIONS: DI - DROP INLET FES - FLARED END SECTION MH - MANHOLE YD - YARD DRAIN RCP - REINFORCED CONCRETE PIPE HDPE - HIGH DENSITY POLYETHYLENE (SMOOTH LINED) PIPENAD 830 SCALE 1"=30' 60'30'INSET A: BIORETENTION DETAIL IN S E T A : B I O R E T E N T I O N D E T A I L 4254304354404 4 5 445420 425 430 435400405410415420 41041542042543043544044544 0 445 450425430 435 4 4 0 400405410400405410415420 425 430 435 440 445 450 390395400390 390 390395 390395395 395395395390400405410390 390 4 0 0 410 415 395 400 4 0 5 400425430420410XXGGGGGGGGUCATVUCATVUFOUFOUCATVUFOUGPUGPUGPUGPUGPUGPUGPUCATVUCATVUFOUFOEXISTING CREEKEXISTING CREEKGOLDSTAR DRIVE SANS 76°23'04" E 289.09'S 78°50'54" E 694.14'S 82°03'46" E 161.57'S 03°07'12" E69.77' (TIE)WOODSS 06°39'34" E 425.85' (TOTAL)N 13° 5 9 ' 3 1 " E 5 5 4 . 1 4 'N 86°00'28" W 1279.26' (TOTAL)35.90'OWNER INFORMATIONPIN NO. 0785316741STATE OF NORTH CAROLINAB.M. 1985, PG. 1399B.M. 1988, PG. 1339B.M. 2011, PG. 451XXXXXXXXOHP OHP OHPOHP 145.03' (TIE)XXXXXXXN 40°24'42" W 1605.78' (GRID)XN 54°31'43" W57.83'1221.43'288.01'137.84'C1C2XX G W W WOWNER INFORMATIONPIN NO. 0785316741STATE OF NORTH CAROLINAB.M. 1985, PG. 1399B.M. 1988, PG. 1339B.M. 2011, PG. 451OWNER INFORMATIONPIN NO. 0785316741STATE OF NORTH CAROLINAB.M. 1985, PG. 1399B.M. 1988, PG. 1339B.M. 2011, PG. 45130' ZONE 1 RIPARIAN BUFFERN60°23'42"W 403.98'PROPOSED PROPERTY LINEBRUSH /SPARSE WOODSBRUSH / SPARSEWOODS50' ZONE 2 RIPARIAN BUFFERWOODSWOODSWOODSWOODSWOODSDISTRICT DRIVE - SR 1774(60' R/W)WADE AVENUE EXTENSION(VARIABLE WIDTH R/W)APPR O X I M A T E L O C A T I O N O F R / W (NOT S U R V E Y E D ) (PLOT T E D F R O M N C D O T PROJ E C T N O . 9 . 9 0 5 0 6 5 3 - S H E E T 4 )WOODSEX. DRAINAGE CHANNELEX. DRAINAGE CHANNELDRAINAGE AREA OF CONCERN UP TO EXISTINGCHANNEL (NO DRAINAGE CHANGES OUTSIDE THISAREA)CONSTRUCTION LIMITSCONSTRUCTION LIMITSCONSTRUCTION LIMITSCONSTRUCTION LIMITS EXISTING CREEKOFFSITE DRAINAGE AREA RE-ROUTEDTHROUGH SITE (THIS AREA IS THE ONLYOFFSITE DRAINAGE AREA THAT IS BEINGCHANGED OR RE-ROUTED).ANALYSIS POINTPRE-DEVELOPMENT DRAINAGEAREA: 17.58 AC.COMPOSITE C: .35TIME OFCONCENTRATION LINEOFFSITE IMPERVIOUS DIGITIZEDFROM AERIAL PHOTOGRAPHYAND DIMENSIONED FROM FIELDVISIT BY ENGINEER.4254304354404 4 5 445420 425 430 435400405410415420 41041542042543043544044544 0 445 450425430 435 4 4 0 400405410400405410415420 425 430 435 440 445 450 390395400390 390 390395 39 0 395395 395395395390400405410390 390 4 0 0 410 415 395 400 4 0 5 400425430420410XXGGGGGGGGUCATVUCATVUFOUFOUCATVUFOUGPUGPUGPUGPUGPUGPUGPUCATVUCATVUFOUFOEXISTING CREEKEXISTING CREEKGOLDSTAR DRIVE SANS 76°23'04" E 289.09'S 78°50'54" E 694.14'S 82°03'46" E 161.57'S 03°07'12" E69.77' (TIE)WOODSS 06°39'34" E 425.85' (TOTAL)N 13° 5 9 ' 3 1 " E 5 5 4 . 1 4 'N 86°00'28" W 1279.26' (TOTAL)35.90'OWNER INFORMATIONPIN NO. 0785316741STATE OF NORTH CAROLINAB.M. 1985, PG. 1399B.M. 1988, PG. 1339B.M. 2011, PG. 451XXXXXXXXOHP OHP OHPOHP 145.03' (TIE)XXXXXXXN 40°24'42" W 1605.78' (GRID)XN 54°31'43" W57.83'1221.43'288.01'137.84'C1C2XX G W W WOWNER INFORMATIONPIN NO. 0785316741STATE OF NORTH CAROLINAB.M. 1985, PG. 1399B.M. 1988, PG. 1339B.M. 2011, PG. 451OWNER INFORMATIONPIN NO. 0785316741STATE OF NORTH CAROLINAB.M. 1985, PG. 1399B.M. 1988, PG. 1339B.M. 2011, PG. 45130' ZONE 1 RIPARIAN BUFFERN60°23'42"W 403.98'PROPOSED PROPERTY LINE50' ZONE 2 RIPARIAN BUFFERDISTRICT DRIVE - SR 1774(60' R/W)WADE AVENUE EXTENSION(VARIABLE WIDTH R/W)APPR O X I M A T E L O C A T I O N O F R / W (NOT S U R V E Y E D ) (PLOT T E D F R O M N C D O T PROJ E C T N O . 9 . 9 0 5 0 6 5 3 - S H E E T 4 )WOODSXXXXXX XXXXXXX X XXXXXXXXXXX-2.25%- 3 . 0 7% -2. 0 3 %-3.20%-1.00%-2. 8 8 % -1.58% -1 .93%-2.83%-1 .42% -1.41%-2.92%420435425425430420 435 410430425420-1 .43% 420 435435 DDD430430425 430TYP. OF 12 INBIORETENTIONSOD WITH CELEBRATION BERMUDA333'272.11'150'150'BIORETENTION SCMEX. DRAINAGE CHANNELEX. DRAINAGE CHANNELDRAINAGE AREA OF CONCERN UP TO EXISTINGCHANNEL (NO DRAINAGE CHANGES OUTSIDE THISAREA)BACONSTRUCTION LIMITSCONSTRUCTION LIMITSCONSTRUCTION LIMITSCONSTRUCTION LIMITS EXISTING CREEKOFFSITE DRAINAGE AREA RE-ROUTEDTHROUGH SITE (THIS AREA IS THE ONLYOFFSITE DRAINAGE AREA THAT IS BEINGCHANGED OR RE-ROUTED).POST-DEVELOPMENT DRAINAGEAREA TO SCM: 6.11 AC.COMPOSITE C: .62POST-DEVELOPMENT BYPASSDRAINAGE AREA: 12.65 AC.COMPOSITE C: .39ANALYSIS POINTTIME OFCONCENTRATION LINEOFFSITE IMPERVIOUS DIGITIZEDFROM AERIAL PHOTOGRAPHYAND DIMENSIONED FROM FIELDVISIT BY ENGINEER.JOB NO.SHEET NO.SCALEDESIGNED BYCHECKED BYDATE DRAWN BYDATEREVISION DESCRIPTION YOUR VISION ACHIEVED THROUGH OURS.5410 Trinity Road, Suite 102 | Raleigh, NC 27607 TEL 919.866.4951 FAX 919.833.8124 www.timmons.com THIS DRAWING PREPARED AT THE RALEIGH OFFICE N O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E R0 3 3 6 1 2N O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RS E A LN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RF R A N C I S S L I N S K Y , I I I24 JULY 2020NORTH CAROLINA NATIONAL GUARD JFHQ RALEIGH HELIPAD 1636 GOLD STAR DRIVE, SUITE 2600, RALEIGH, NORTH CAROLINA 27607 | NCSCO CASE #: 17-16713-01A42866 WAFSFSNTSNORTH CAROLINA LICENSE NO. C-1652 6/24/20STORMWATER FAST TRACK ATC SUBMITTAL06/24/2020LEGENDEXISTING OFFSITE IMPERVIOUS (BYPASS)(1.94 ± ACRES)ANALYSIS POINTDRAINAGEAREA(Acres)COMPOSITE CQ1Q10POST-DEVELOPMENTB12.65.396.6011.11POST-DEVELOPMENTAPOST-DEVELOPMENTTOTAL = A + B4.93.625.376.2217.587.1816.77POST-DEVELOPMENT WATER QUANTITY SUMMARYNOTE: POST-DEVELOPMENT FLOW IS LESS THAN PRE-DEVELOPMENT FLOW FOR THE 1-YEAR, 24-HOUR STORM ATANALYSIS POINT. REFER TO CALCULATION BOOKLET FOR ADDITIONAL INFORMATION.Q10015.477.9623.39DRAINAGE AREAANALYSIS POINTDRAINAGEAREA(Acres)COMPOSITE CPRE-DEVELOPMENT17.58Q1Q10.359.4315.87NOTE: POST-DEVELOPMENT FLOW IS LESS THAN PRE-DEVELOPMENT FLOW AT ANALYSIS POINT.REFER TO CALCULATION BOOKLET FOR ADDITIONAL INFORMATION.Q10022.09PRE-DEVELOPMENT WATER QUANTITY SUMMARYC4.1STORMWATER MANAGEMENT PLAN NAD 830SCALE 1"=100'200'100'1" = 100'ON-SITE BUILDINGSDRAINAGE BASIN BUILT UPON AREAON-SITE STREETSON-SITE PARKINGON-SITE SIDEWALKSFUTURETOTAL IMPERVIOUSTOTAL DRAINAGE AREA00118,27500119,081266,245DRAINAGE AREA ABUA TYPE(SF)(SF)(SF)(SF)(SF)(SF)(SF)00118,27500119,081550,548PROJECT AREA1.ALL PROPOSED IMPERVIOUS AREA IS CAPTURED IN THE BIORETENTION CELL.2.A BIORETENTION CELL IS BEING PROVIDED TO CONTROL AND TREAT RUNOFF FROM THE DEVELOPMENT AREA INDRAINAGE AREA A.3.FOR STORMWATER MANAGEMENT, THERE IS ONE ANALYSIS POINT IN AN EXISTING CREEK TO THE NORTHWEST OFTHE SITE. DRAINAGE AREA 'A' IS THE AREA WITHIN THE DISTURBED AREA THAT DRAINS TO THE BIORETENTION CELL. DRAINAGE AREA 'B' IS THE AREA WITHIN THE DISTURBED AREA THAT DRAINS TO THE ANALYSIS POINT BUT BYPASSESTHE BIORETENTION. POST DEVELOPMENT RUNOFF HAS BEEN DESIGNED TO BE LESS THAN PRE DEVELOPMENTRUNOFF FOR THE 1 YEAR, 24 HOUR STORM AT THE ANALYSIS POINT.4.THIS DRAWING IS FOR AGENCY REVIEW ONLY - NOT FOR CONSTRUCTION.5.THERE ARE NO WETLANDS ON-SITE, AS DETERMINED BY TIMMONS GROUP (REFER TO WATERS OF THE USDELINEATION PACKAGE IN THE ATTACHED NARRATIVE AND CALCULATIONS BOOK).NOTESCOMMENTSDRY DETENTION SCMBYPASS TOANALYSIS POINTQ POST < Q PREPOST-DEVELOPMENT ONSITE IMPERVIOUS CAPTURED IN SCM(2.73 ± ACRES)TIME OF CONCENTRATION FLOW LINENAD 830SCALE 1"=100'200'100'PRE-DEVELOPMENTPOST-DEVELOPMENTPOST-DEVELOPMENT WATER QUALITY SUMMARYOFF-SITE836(SF)836 N.T.S.BIORETENTION STORMWATER CONTROL MEASURE (SCM)1 NOTE EMBANKMENT SHALL BE CONSTRUCTED OF CLEAN STRUCTURAL SOIL, FREE OF ROOTS, VEGETATION, ROCKS & OTHER OBJECTIONABLE MATERIAL. SCARIFY SURFACES BEFORE PLACING FILL. PLACE FILL IN 6-8 INCH LOOSE LIFTS. COMPACT TO AT LEAST 95% OF THE STANDARD PROCTOR DENSITY. IMPERVIOUS LAYER TO BE INSTALLED UNDER ALL WATER SURFACES. REFER TO SPECIFICATION SECTIONS 312000 BMP / WETPOND CONSTRUCTION SHALL BE UNDER THE SUPERVISION OF THE OWNERS GEOTECHNICAL CONSULTANT. DAM EMBANKMENT CONSTRUCTION STANDARDS 1.CONTROLLED FILL, AS SPECIFIED BY THE GEOTECHNICAL ENGINEER, IN THE DAM EMBANKMENT SHALL BE PLACED IN 6-INCH LOOSE LAYERS (3-INCH LOOSE LAYERS WITHIN 3-FEET OF EITHER SIDE OF THE PRINCIPAL SPILLWAY PIPE TO A DEPTH OF 2-FEET OVER THE PIPE) AND SHALL BE COMPACTED TO A DENSITY OF NO LESS THAN 95% OF THE STANDARD PROCTOR MAXIMUM DENSITY AT A MOISTURE CONTENT OF + OR - TWO PERCENTAGE POINTS OF THE OPTIMUM MOISTURE CONTENT IN ACCORDANCE WITH ASTM D698. 2.ALL VISIBLE ORGANIC DEBRIS SUCH AS ROOTS AND LIMBS SHALL BE REMOVED FROM THE FILL MATERIAL PRIOR TO COMPACTION TO THE REQUIRED DENSITY. SOILS WITH ORGANIC MATTER CONTENT EXCEEDING 5% BY WEIGHT SHALL NOT BE USED. STONES GREATER THAN 3-INCH (IN ANY DIRECTION) SHALL BE REMOVED FROM THE FILL PRIOR TO COMPACTION. 3.FILL MATERIAL PLACED AT DENSITIES LOWER THAN SPECIFIED MINIMUM DENSITIES OR AT MOISTURE CONTENTS OUTSIDE THE SPECIFIED RANGES OR OTHERWISE NOT CONFORMING TO SPECIFIED REQUIREMENTS SHALL BE REMOVED AND REPLACED WITH ACCEPTABLE MATERIALS. 4.ANY FILL LAYER THAT IS SMOOTH DRUM ROLLED TO REDUCE MOISTURE PENETRATION DURING A STORM EVENT SHALL BE PROPERLY SCARIFIED PRIOR TO THE PLACEMENT OF THE NEXT SOIL LIFT. 5.SURFACE WATER AND STREAM FLOW SHALL BE CONTINUOUSLY CONTROLLED THROUGHOUT CONSTRUCTION AND THE PLACEMENT OF CONTROLLED FILL. 6.FOUNDATION AREAS MAY REQUIRE UNDERCUTTING OF COMPRESSIBLE AND/OR UNSUITABLE SOILS IN ADDITION TO THAT INDICATED ON THE PLANS. ALL SUCH UNDERCUTTING SHALL BE PERFORMED AT THE DISCRETION OF THE GEOTECHNICAL ENGINEER AND SHALL BE MONITORED AND DOCUMENTED. IN NO CASE SHALL THERE BE AN ATTEMPT TO STABILIZE ANY PORTIONS OF THE FOUNDATION SOILS WITH CRUSHED STONE. 7.TREATMENT OF SEEPAGE AREAS, SUBGRADE PREPARATION, FOUNDATION DEWATERING AND ROCK FOUNDATION PREPARATION (I.E., TREATMENT WITH SLUSH GROUTING, DENTAL CONCRETE, ETC.) MAY BE REQUIRED AT THE DISCRETION OF THE GEOTECHNICAL ENGINEER. ALL SUCH ACTIVITIES SHALL BE CLOSELY MONITORED AND DOCUMENTED BY THE GEOTECHNICAL ENGINEER. 8.FILL ADJACENT TO THE RISER AND PRINCIPAL SPILLWAY PIPE SHALL BE PLACED SO THAT LIFTS ARE AT THE SAME LEVEL ON BOTH SIDES OF THE STRUCTURES. 9.EARTHWORK COMPACTION WITHIN 3-FEET OF ANY STRUCTURES SHALL BE ACCOMPLISHED BY MEANS OF HAND TAMPERS, MANUALLY DIRECTED POWER TAMPERS OR PLATE COMPACTORS OR MINIATURE SELF-PROPELLED ROLLERS. 10.COMPACTION BY MEANS OF DROP WEIGHTS FROM A CRANE OR HOIST SHALL NOT BE PERMITTED. 11.HEAVY EQUIPMENT SHALL NOT BE ALLOWED TO PASS OVER CAST-IN-PLACE STRUCTURES (INCLUDING THE CRADLE) UNTIL ADEQUATE CURING TIME HAS ELAPSED. 12.TO RE-ESTABLISH VEGETATION AFTER CONSTRUCTION, A 2- TO 3-INCH LAYER OF TOPSOIL SHALL BE PLACED ON THE DISTURBED EMBANKMENT SURFACE AND THE AREA SEEDED AND MULCHED OR HYDROSEEDED. TESTING, OBSERVATION, AND CERTIFICATION 1.TESTS OF THE DEGREE (%) OF COMPACTION OF THE PLACED FILL IN THE DAM SHALL BE PERFORMED AS A PART OF THE PERMITTEE'S NORMAL QUALITY CONTROL PROGRAM FOR THE CONSTRUCTION OF THE DAM. TESTS SHALL BE CONDUCTED CONCURRENT WITH THE INSTALLATION OF THE COMPACTED FILL AND THE CONTRACTOR SHALL COORDINATE THE CONSTRUCTION OF THE DAM SO THAT THE TESTING CAN BE COMPLETED. SHOULD THE RESULTS OF THE TESTS INDICATE THAT THE SPECIFIED DEGREE OF COMPACTION HAS NOT BEEN OBTAINED; THE PORTIONS OF THE DAM REPRESENTED BY SUCH TESTS SHALL BE REWORKED OR REBUILT. ALL PORTIONS OF THE DAM SHALL ACHIEVE THE SPECIFIED MINIMUM DEGREE OF COMPACTION. 2.CONSTRUCTION OF CLASS A, B AND C DAM EMBANKMENTS SHALL BE DONE UNDER THE OBSERVATION OF A QUALIFIED GEOTECHNICAL ENGINEER, WHO IS REGISTERED AS A PROFESSIONAL ENGINEER IN THE STATE OF NORTH CAROLINA. THE GEOTECHNICAL ENGINEER MUST HAVE EXPERIENCE IN THE DESIGN AND CONSTRUCTION MONITORING OF DAMS OF THE SIZE AND SCOPE COVERED BY THESE STANDARDS AND GUIDELINES. 3.ON CLASS A, B, AND C DAMS (WITH THE EXCEPTION OF DETENTION ONLY CLASS C DAMS THAT COLLECT DRAINAGE FROM AN AREA OF 25-ACRES OR LESS), THE GEOTECHNICAL ENGINEER, AS DEFINED ABOVE, SHALL OBSERVE ALL ASPECTS OF THE CONSTRUCTION OF THE DAM (I.E., PREPARATION OF THE FOUNDATION, INSTALLATION OF THE CUT-OFF TRENCH, INSTALLATION OF THE PRINCIPAL SPILLWAY PIPE, INSTALLATION OF THE INTERNAL DRAINAGE, INSTALLATION OF COMPACTED FILL, ETC.). THE FREQUENCY OF OBSERVATION AND TESTING MUST BE SUFFICIENT FOR THE GEOTECHNICAL ENGINEER (OR THE DESIGN ENGINEER ON CLASS D DAMS AND CLASS C, DETENTION ONLY, DAMS) TO STATE, IN HIS/HER PROFESSIONAL OPINION, THAT THE SPECIFIC ITEMS OBSERVED AND TESTED WERE INSTALLED IN ACCORDANCE WITH THE APPROVED CONSTRUCTION DRAWINGS AND SPECIFICATIONS. REFERENCE IS MADE TO THE CITY OF DURHAM “ ” PLANTING SOIL BED MIXTURE SOLUBLE SALTS P-INDEX FINES (SILT AND CLAY) SAND pH RANGE 500 PPM MAXIMUM 9% (ACCEPTABLE RANGE: 8-15%) 82% (ACCEPTABLE RANGE: 75-85%) 10-30 5.2 TO 7.00 ORGANIC MATERIAL (PINE BARK FINES)9% (ACCEPTABLE RANGE: 5-10%) LANDSCAPE WARRANTIES SHALL APPLY TO BIORETENTION AREA PLANTINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTENANCE UNTIL SUBSTANTIAL COMPLETION AT WHICH TIME OWNER WILL ASSUME MAINTENANCE RESPONSIBILITY. BIORETENTION AREA MAINTENANCE SCHEDULE METHOD SPECIFICATIONS SEE PLANTING OR BY HAND MECHANICAL BY HAND MECHANICAL INSPECT AND REPAIR DAYS AFTER PLANTING FOR 14 CONSECUTIVE AND END OF EACH DAY WATER PLANT MATERIAL PLANTS NOT TO BE REMOVED TREAT ALL DISEASED TREATMENT CONSIDERED BEYOND DISEASED VEGETATION REPLACE ANY DEAD OR EROSION DESCRIPTION ALLMONTHLYVISUAL MAR 15 - APR 30 OCT 1 - NOV 30 TWICE PER YEAR WHENEVER NEEDED IMMEDIATELY AFTER COMPLETION OF MONTHLY PROJECT ALL N/A ALL GRASS FREQUENCY SOIL SEASON OUTLET STRUCTURE SCALE: N.T.S. 1"/HOUR MIN, 6"/HOUR MAX. 1-2"/HOUR PREFERRED PERMEABILITY BIORETENTION SECTION 4'-0" OUTLET NON-WOVEN FILTER FABRIC TOP OF SOD ELEV= 426.00' 12" SHALLOW PONDING RIM ELEV= 427.50' N.T.S. BIO-RETENTION AND EMBANKMENT SECTION 3 1 10' IMPERVIOUS FILL COMPACTED TOP OF EMBANKMENT ELEV.: 429.00' UNDERDRAIN INV ELEV.: 422.50'18" RCP WITH RUBBER GASKET (ASTM C-443) SCALE: N.T.S. 3 1 1 1 RIM ELEV: 427.50' TOP OF SOD ELEV: 426.00' FOLLOWING FULL STABILIZATION OF THE SITE AND APPROVAL BY NCDENR INSPECTOR AND REMOVE PERIMETER SILT FENCE AND STABILIZE RESULTING DISTURBED AREAS. SILT FENCE BELOW TRAPS AND BASINS SHALL REMAIN IN PLACE UNTIL CONVERSION TO PERMANENT FACILITIES AND FINAL STABILIZATION ARE COMPLETE. THE SITE ENGINEER, CONVERT SEDIMENT BASINS AND TRAPS TO FINAL BIO-RETENTION FINE GRADE INTERIOR OF DEVICE. REPAIR ALL REMAINING DISTURBED AREAS WITH SOD OR RE-SEED AND COVER PERFORM GRASS MAINTENANCE UNTIL FULL COVERAGE IS OBTAINED. AREAS AS FOLLOWS: REMOVE ACCUMULATED SEDIMENT AND EXCAVATE TO SUB DRAIN ELEVATIONS, BIO-RETENTION AREA CONSTRUCTION SEQUENCE DISPOSE OF EXCAVATED MATERIALS AND SEDIMENT OFF-SITE. PLACE PLANTING SOIL MIX IN DEEP, UNCOMPACTED LIFTS STARTING AT FAR END OF DO NOT LEAVE STONE EXPOSED WITHOUT FILTER FABRIC COVER. STAND OF VEGETATION. ENSURE ENTIRE PERIMETER OF BIO-RETENTION AREA IS STABILIZED WITH A HEALTHY REPAIR ANY DAMAGED VEGETATED PERIMETER AREAS WITH SOD OR RE-SEED AND COVER WITH EXCELSIOR SLOPE PROTECTION MATTING. INSTALL SILT FENCE AS NEEDED TO KEEP ANY SEDIMENT FROM DRAINING INTO EXCAVATION. CELL TO AVOID PLACING EARTH MOVING EQUIPMENT ON PLACED SOIL. NO HEAVY EQUIPMENT SHALL BE ALLOWED ONTO THE PLANTING SOIL. INSTALL ALL PLANT MATERIAL BY HAND. FINE GRADE SURFACE PLANTING SOIL BED BY HAND. PLANTING SOIL BED. INSTALL RIPRAP ENERGY DISSIPATERS WITHOUT PLACING HEAVY EQUIPMENT ON REMOVE FAIRCLOTH SKIMMER AND PATCH HOLE. WITH SLOPE PROTECTION MATTING. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. AS-BUILT SURVEY REQUIREMENTS SPILLWAY WEIR: 428.00' SOD WITH CELEBRATION BERMUDA 10-IN #57 WASHED STONE (3" MIN. ON TOP AND SIDES) SHWT ELEV= 420.00' INV ELEV.: 422.5' 12" UPTURNED ELBOW FOR IWS SUB-DRAIN 6" SCH 40 PVC PERFORATED PIPE 2-IN WASHED SAND 30-IN PLANTING SOIL BED PLACE IN 10" LIFTS LOOSELY COMPACTED INSTALL SLOPE PROTECTION MATTING ON ALL SLOPES STEEPER THAN 6:1 AND FLOOR OF POND PROTECT PLANTING SOIL WITH PERIMETER SILT FENCE AND A TEMPORARY COVER OF NON-WOVEN DRAINAGE (FILTER) FABRIC UNTIL COMPLETE SITE STABILIZATION IS ACHIEVED. REMOVE SILT FENCE AND DRAINAGE FABRIC AND INSTALL MULCH AND PLANT MATERIAL ONCE SITE IS COMPLETELY STABILIZED WITH PERMANENT GROUND COVER. NOTES: -PLANTING MEDIA FOR BIO-RETENTION SHOULD BE UNIFORM FREE OF STONES, STUMPS, ROOTS OR OTHER SIMILAR MATERIAL GREATER THAN 2 INCHES AND MEET THE SPECIFICATION NOTED ABOVE. -SM, ML, SC SOIL CLASSIFICATIONS (USCS) -SOURCE OF PLANTING SOIL BED MIXTURE: TRIANGLE LANDSCAPE SUPPLIES -PROTECT PLANTING SOIL WITH PERIMETER SILT FENCE AND INSTALL SOD ON SIDE SLOPES. -REMOVE SILT FENCE AND DRAINAGE FABRIC ONCE SITE IS STABILIZED WITH PERMANENT GROUND COVER. -INSTALL PLANT BED SOIL ONCE THE SITE IS STABILIZED AND THE BIO-RETENTION AREA IS NO LONGER UTILIZED AS A TEMPORARY SEDIMENT BASIN. -PLACE IN 12-18" LOOSE LIFTS, LOOSELY COMPACTED WITH BACKHOE BUCKET. -PEFORATED SUB-DRAIN PIPES SHALL HAVE A MINIMUM OF 4 ROWS OF STAGGERD PERFORATIONS EQUIDISTANT AROUND THE PERIMETER OF THE PIPE, PERFORATIONS IN EACH ROW SHALL BE SPACED 6-IN O.C. PERFORATION SHALL BE 3/8" DIAMETER. 12" UPTURNED ELBOW FOR INTERNAL WATER STORAGE LAYER 18" TO SURFACE MIN. (424.00) INSTALL SUBDRAIN PIPING WASHED STONE DRAINAGE LAYER AND FILTER FABRIC. OUTLET BARREL RCP PIPE DIA=18" OUTLET BARREL 18" RCP PIPE INV. ELEV.: 422.304'-0"4'-0"5" MIN. WALL (TYP) PLAN VIEW SECTION X-X SECTION Z-ZSECTION Y-Y YYX XZZOUTLET BARREL RCP PIPE DIA=18" 5" MIN. WALL (TYP) 5" MIN. WALL (TYP) 5" MIN. WALL (TYP) ELEV.:422.50 UNDERDRAINS OUTLET BARREL RIM ELEV.: 427.50 4'-0"4'-0" 4'-0"5"16"16"5"16"5"ADDITIONAL CLASS B CONCRETE IN BOTTOM OF STUCTURE ADDITIONAL CLASS B CONCRETE IN BOTTOM OF STUCTURE EMBANKMENT EMBANKMENT SLOPE PEAKED ROOF TRASH RACK MATERIAL: ALUMINUM WITH 25 YEAR DESIGN LIFE 6"6"2'-6"4'-10" 3" x 3" OPENINGS (6) 1/2" X 4" STAINLESS STEEL BOLTS PER SIDE (TYP). WELDED ALUMINUM BAR GRATING 3" x 3" OPENINGS PEAKED ROOF TRASH RACK A:MATERIAL: ALUMINUM WITH 25 YEAR DESIGN LIFE PEAKED ROOF TRASH RACK A:MATERIAL: ALUMINUM WITH 25 YEAR DESIGN LIFE WELDED ALUMINUM BAR GRATING 3" x 3" OPENINGS WELDED ALUMINUM BAR GRATING 3" x 3" OPENINGS STAINLESS STEEL BOLTS (TYP). 30" x 24" LOCKABLE ACCESS HATCH WITH HINGES 6"6"2'-6"1/2" STEEL PLATE (6)1/2" X 4" STAINLESS STEEL BOLTS PER SIDE (TYP). BOTTOM OF MEDIA ELEVATION = 422.50 6" UNDERDRAIN INV. ELEV.:422.50 ELEV.:422.30 3 1 SEED & MULCH EMBANKMENT SEE SEEDING SCHEDULE (INSTALL SLOPE PROTECTION MATTING ON ALL SLOPES STEEPER THAN 6:1) INV IN=419.90 PROPOSED MANHOLE C2 (SEE SHEET C4.0) ONE CONC. ANTI-SEEP COLLAR (6" WIDE) UNDER CENTER OF EMBANKMENT2-FT2-FTIMPERVIOUS FILL COMPACTED BARREL OUTLET INV ELEV.: 422.30' UPTURNED ELBOW ON 6" UNDERDRAIN PIPE (4) SOD ELEV.: 426.00SOD ELEV.: 426.00SOD ELEV.: 426.00 UPTURNED ELBOW ON 6" UNDERDRAIN PIPE (4) COMPACTED SUBGRADE (SEE SPECS) OUTLET STRUCTURE & SPLITTER BOX NOTES: 1. 2. 3. OF THE BOTTOM SLAB. 4. ALL STRUCTURES OVER 3'-6" IN DEPTH TO BE CLASS "A" (3,000 PSI) CONCRETE TO BE USED. PROVIDED WITH STEPS 1'-2" ON CENTERS. STEPS SHALL BE IN ACCORDANCE WITH STANDARD 840.66. FORMS ARE TO BE USED FOR THE CONSTRUCTION ALL MOTOR JOINTS ARE 1/2" ± 1/8" OUTLET STRUCTURE 6"PVC 24" MIN.24" MIN.6" PVC END CAP 6" PVC TEE ANCHOR DRAWDOWN PIPE TO WALL WATERTIGHT NON-SHRINK GROUT ANTI-SEEP COLLAR ENLARGEMENT UNDERDRAIN ELBOW ENLARGEMENT 6" PVC UNDERDRAIN INV=422.50 24" RCP 12" PVC CLEANOUT 2' ABOVE PLANTING SURFACE WITH GLUED FITTINGS AND SCREW CAP (TYP.) CONVERT TO 6" SOLID WALL PVC PIPE PRIOR TO ENTERING THE OUTLET STRUCTURE (TYP.) SCALE: N.T.S. EMERGENCY SPILLWAY SECTION 3 1 8-FT WEIR WIDTH SPILLWAY CREST ELEV: 428.00 12-IN THICK CLASS B RIPRAP OVER FILTER FABRIC 31TOP OF EMBANKMENT ELEV: 429.00 1-YR STORM ELEV=427.49 2-YR STORM ELEV=427.64 10-YR STORM ELEV=427.69 100-YR STORM ELEV=427.73 CONTRACTOR SHALL PROVIDE SIGNED, SEALED AND DATED AS-BUILT SURVEY PLANS PERFORMED BY A PROFESSIONAL LAND SURVEYOR THAT INCLUDES THE FOLLOWING: ·BIO-RETENTION AREA DIMENSIONS ·AREA OF BERMUDA SOD ·ELEVATIONS ·SIDE SLOPES ·BENCHMARK FOR CLEANOUT ·INLET DEVICES AND ENERGY DISSIPATERS ·OUTLET STRUCTURE INVERTS ·ORIFICE DIAMETER ·PIPE SIZES ·CLEANOUT LOCATIONS AND ELEVATIONS ·PLAN AND CROSS-SECTION VIEW AT A SCALE OF 1"=30' OR LARGER ·CROSS SECTION ·TOPOGRAPHY SHALL EXTENDED TO 20 FEET OUTSIDE LIMITS OF BIO-RETENTION AREA. CONTRACTOR SHALL PROVIDE SPECIFICATION SHEETS FOR MATERIALS USED IN THE SCM SUCH AS PLANTING MEDIA, FILTER MEDIA AND AGGREGATE. MOW GRASS ONCE ESTABLISHED AS NECESSARY TO MAINTAIN PLANT HEALTH VALVE INV.: 426.00 BIORETENTION PLANTING SOIL JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.5410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICEN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E R 0 3 3 6 1 2N O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E R S E A LN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RF R A N C I S S L I N S K Y, I I I24 JULY 2020 NORTH CAROLINA NATIONAL GUARD JFHQ RALEIGH HELIPAD1636 GOLD STAR DRIVE, SUITE 2600, RALEIGH, NORTH CAROLINA 27607 | NCSCO CASE #: 17-16713-01A42866 WA FS FS NTS NORTH CAROLINA LICENSE NO. C-16526/24/20 STORMWATER FAST TRACK ATC SUBMITTAL06/24/2020C5.7 BIORETENTION NOTES & DETAILS