Loading...
HomeMy WebLinkAboutWQ0041746_Application (FTSE)_20200608i State of North Carolina DW. Department of Environmental Quality RDivision of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: O (� obe completed by DWR) All items must be completed or the application will be returned 1. APPLICANT INFORMATION: 1. Applicant's name- Town of Smithfield (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Federal ❑ StatelCounty ® Municipal 3. Signature authority's name; Ted Credle per 15A NCAC 02T .0106(b) Title: Public Utilities Director 4. Applicant's mailing address: 230 Hospital Road City: Smithfield State: NC Zip: 27577-_ 5. Applicant's contact information: Phone number: (919) 934-21 I6 Email Address: ted.credlePsmithfield-nc.com 11. PROJECT INFORMATION: ❑ Privately -Owned Public Utility [0060pt of Environmental Quality JUN 8 2020 Raleigh Regional office 1. Project name: Johnston County Detention Center 2. ApplicationlProject status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number. WQ00 and issued date: If new construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Johnston 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.501662' Longitude:-78.307547 5. Parcel ID (if applicable): 260300-67-6920 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: i. Professional Engineer: Chad Simmons, PE License Number: 40363 Firm: McGill Associates Mailing address: 5400 Trinity Road, Suite 107 City: Raleigh State: NC Zip: 27607- Phone number: (919) 378-91 1 1 Email Address: chad.simmons me illassociates.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: I. Facility Name: Central Johnston Counter WWTP Permit Number: NCO030716 Owner Name: Johnston County Public Utilities o V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ_ Downstream (Receiving) Sewer Size: inch ! 5stcm Wide C'allcction System Permit N_u_mbeL(s if annlicabl_e_): WQCS Owner Namc(s):�� FORM: FTA 04-16 Page 1 of 5 THE COMPLETED APPLICATION PACKAGE INCLDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE: REGIONAL OFFICE ADDRESS COUNTIES SERVED Asheville Regional Office 2090 US Highway 70 Avery, Buncombe, Burke, Caldwell, Cherokee, Water Quality Section Swannanoa, North Carolina 28778 Clay, Graham, Haywood, Henderson, Jackson, (828) 2964500 Macon, Madison, McDowell, Mitchell, Polk, (828) 299-7043 Fax Rutherford, Swain, Transylvania, Yancey Fayetteville Regional Office 225 Green Street Suite 714 Anson, Bladen, Cumberland, Harnett, Hoke, Water Quality Section_ Fayetteville, North Carolina 28301-5094 Montgomery, Moore, Robeson, Richmond, (910) 433-3300 Sampson, Scotland (910) 486-0707 Fax Mooresville Regional Office 610 E. Center Avenue Alexander, Cabarrus, Catawba, Cleveland, Water Quality Section Mooresville, North Carolina 28115 Gaston, Iredell, Lincoln, Mecklenburg, Rowan, (704) 663-1699 Stanly, Union (704) 663-6040 Fax Raleigh Regional Office 1628 Mail Service Center Chatham, Durham, Edgecombe, Franklin, Water Quality Section Raleigh, North Carolina 27699-1628 Granville, Halifax, Johnston, Lee, Nash, (919) 791-4200 Northampton, Orange, Person, Vance, Wake, (919) 788-7159 Fax Warren, Wilson Washington Regional Office 943 Washington Square Mall Beaufort, Bertie, Camden, Chowan, Craven, Water Quality Section Washington, North Carolina 27889 Currituck, Dare, Gales, Greene, Hertford, Hyde, (252) 946-6481 Jones, Lenoir, Martin, Pamlico, Pasquotank, (252) 975-3716 Fax Perquimans, Pitt, Tyrrell, Washington, Wayne Wilmington Regional Office 127 Cardinal Drive Extension Brunswick, Carteret, Columbus, Dupiin, New Water Quality Section Wilmington, North Carolina 28405 Hanover, Onslow, Pender (910)796-7215 (910) 350-2004 Fax Winston-Salem Regional Office 450 W. Hanes Mill Road Alamance, Alleghany, Ashe, Caswell, Davidson, Water Quality, Section Suite 300 Davie, Forsyth, Guilford, Rockingham, Randolph, Winston-Salem, North Carolina 27105 Stokes, Surry, Watauga, Wilkes, Yadkin (336) 776-9800 INSTRUCTIONS FOR FORM: FTA 04-116 & SUPPORTING DOCUMENTATION Page 3 of VI. GENERAL REQUIREMENTS I. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Ycs ❑No ®NIA 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes [:]No ®NIA 3. If the Applicant is a Homc Propervy Owners' Association has an Operational Agreement (FORM: HOA) been attached? ❑ Yes ❑No ®N;'A 4. Origin of wastewater: (check all that apply): ❑ Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School l preschool i day care ❑ Medical I dental I veterinary facilities ❑ Swimming Pool lClubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses..' offices / factories ❑ Nursing Home ® Other (Explain in Attachment) 5. Nature of wastewater. 100 % DomesticiCommercial 0 % Commercial _ % Industrial (See 15A NCAC 02T .0103(20)) 'Is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Has a Flow reduction been approved under 15A NCAC 02T .0114 ? ❑ Yes ® No T- If yes, provide a cony of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 211.0114 Daily Design Flow 's No. of Units Flow Institution - Inmate 120 gal/day 400 48,000 GPD Institution - Staff I0 galiday 100 1,000 GPD gall GPD gal/ GPD gal/ GPD gall GPD Total 49,000 GPD a See I SA NCAC 02T .01 14(b). (d). (c)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or cast of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0I 14(c), design flow rates for establishments not identified [in table 15A [qCAC 01T.0114) shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 49,000 GPD (per 15A NCAC 02T .0114) Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this Iine ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Pagc 2 of 5 VI1. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC(Gravity Sewers : 1. Summarize gravity sewer to be permitted_ Size (inches) Length (feet) Material g 51 DIP ➢ Section 11 & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIii. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Paimp Stations. -Force plains : COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: — 2- Approximate Coordinates (Decimal Degrees): Latitude: !�' Longitude: - 3. Design flow of the pump station: ._ _ millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at _ feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with 15A NCAC 02T .030�: ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B): ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): i- It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (028.0200 & 15A NCAC 02T.0305(f)): 1. Does the project comply with all separations found in 15A NCAC 021.0�105 & > 15A NCAC 02T.0305(f) contains minimum separations that shall he provided fnr sewer evetPmr- ® Yes ❑ No Setback Parameter* Separation Required Storm sewers and other utilities not listed below vertical 24 inches Water mains vertical -water over sewer including in benched trenches 18 inches Water mains horizontal 10 feet Reclaimed water lines vertical - reclaimed over sewer 18 inches Reclaimed water lines horizontal - reclaimed over sewer 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class If impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-1 or WS-V), B, SA, ORW, HQW, or SB from normal high water or tide elevation and wetlands see item IX.2 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet AnX basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimm ng pools 10 feet Final earth gmde vertical 36 inches �i, 15A NCAC 02T.0305(e) contains alternatives where separations in 02T.0305(f) cannot be achieved. **Stream classifications can be identified using the Division's NC Surface Water Classifications webpaee D If noncompliance with 02T.0305(f) or (g). see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ® Yes ❑ No ❑ N/A See the Division's draft separation requirements for situations where separation cannot be meet No variance is required if the alternative design criteria specified is utilized in design and construction t As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑ Yes ❑ No ® N.-'A ►- This would include Trout Buffered Streams per 15A NCAC 213.0202 4. Does the project require coveragelauthorization under a 404 Nationwide or ❑ Yes ® No individual permits or 401 Water Quality Certifications? r- Information can be obtained from the 401 & Buffer Permitting Branch 5. Does project comply with 15A NCAC 02T.0105(c)i6) (additional permits/certifications)? ® Yes ❑ No Per 1.5A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ® No ❑ N/A If yes, include an attachment with details for each line, including type (aerial line, size, material, and location) High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: Does the submitted system comply with 1 SA NCAC 02T, the Minim um_Dcsign Criteria for the Permitting, of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria latest version as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Arivroval of the request is required Prior to submittal of the Fast Track Arinlication and supoorting documents. 2. Professional Engineer's Certification: 1, _ t:1/Enl f= L 1/1/i IA/1� Jsjs attest that this application for (Professional Engineer's name from Application Item 111.1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: :C17 SEAL r; r 40363 3. Applicant's Certification per 15A NCAC 02T .0106(b): G,r _ kc , Pi r4G 6 r o � �v_�o � + e- ) +-, I + I-"�5 attest that this application for (Signature Authority's name & title from Application Item 1.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. 1 understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution_ I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: i-t-tJl _cL__ pate: {0 — 5_," FORM: FTA 04-16 Page 5 of 5 I Fri �� III Shaping Communities Together J FIGURE F-1 SELMA, NC AND FOR OAKS NE, NC — USGS 7.5min Quad Map — 2019 MCGILL ASSOCIATES 5400 TRINITY ROAD, SUITE 107, RALEIGH, NC 27607 1919.378.9111 / MCGILLASSOCIATES.COM L A ��� �I Shaping Communities Together J FIGURE F-2 AERIAL LOCATION MAP, JOHNSTON COUNTY GIS MCGILL ASSOCIATES 5400 TRINITY ROAD, SUITE 107, RALEIGH, NC 27607 / 919.378,9111 J MCGILLASSOCIATES.COM State of North Carolina Department of Environmental Quality { Division of Water Resources Nk Division of Waiter Resources Flow Tracking for Sewer .Extension Applications (FTSE 10-18) Entity Requesting Allocation: Smithfield (connection to JCS stem Project Name for which flow is being requested: Johnston County Detention Center More that one FTSE may be regtrlrerl for a single project if the owner of the WWTP is not responsible for al! pump stations along the route of the proposed wasteipater flaw. 1. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Central JohnstonCounty Regional WW Facility b. WWTP Facility Permit #: NC 030716 All flows are in MGD c. WWTP facility's permitted flow 9.5 d. Estimated obligated flow not yet tributary to the WWTP 1.8724 e. WWTP facility's actual avg. flow 5.970 f. Total flow for this specific request 0.0490 g. Total actual and obligated flows to the facility 7.8913 h. Percent of permitted flow used 62.8% actual, 83.1 % paper II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations Iocated between the project connection point and the WWTP: (A) (B) (C) (D)-(B+C) (E)=(A-D) Design Obligated, Pump Pump Average Approx. Not Yet Total Current Station Station Firm Daily Flow** Current Tributary Flow Plus (Name or Permit Capacity, * (Firm / pf), Avg. Daily Daily Flow, Obligated Available Number) No. MGD MGD Flow, MGD MGD Flow Capacity*** NONE * The Firm Capacity (design Row) of any pump station is defined as the maximum pumped flow that can he achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): CJCRWWTF Downstream Permit Number: NC 0030716 Page 1 of 6 UIrVC 1A 10 III. Certification Statement: I Ted Credle certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. 4--13-z.o Signing Official Signalin•e Dale Ps' e.� rr � Pti1 li-e L� �►f //�i�'1'�S l v W ri o� �h�1� -f'i17 +`�� � Title of Signing Official �� Got1�G�ia� $5!'�� 4� Page 2 of 6 FTSE 14-18 III. Certification Statement: I _ Chandra C. Farmer, P.E. �Y certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with Iocal established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. Signing Official Signature fAw( 9 W11AMN Title of Signing Official Page 2 of 6 FTe P 1 !L 1 Q IVA Shaping Communities Together ethermeJi'I June 5, 2020 NC Dept of Environmental Quality Division of Water Resources Raleigh Regional Office North Carolina Department of Environmental Quality 3800 Barrett Drive Raleigh, NC 27609 To Whom it May Concern, JUN - 8 2020 Raleigh Regional Office RE: Fast Track Sewer Extension Application Johnston County Detention Center Johnston County, North Carolina Please find the following items enclosed for your review: 1. One (1) original Fast -Track Sewer System Extension Application with supporting maps_ 2. One (1) copy of a Fast -Track Sewer System Extension Application with supporting maps. 3. Two (2) copies of the Flow Tracking Form. 4. Review fee check in the amount of $480.00. This project includes approximately 51 linear feet of gravity sewer extension to serve a property to be developed as a new detention facility in Smithfield, NC. The new line will tie into the Town of Smithfield's existing gravity sewer line. If you have any questions or require additional information regarding this application, please feel free to contact me at (919) 378-9111. Sincerely, McGILL ASSOCIATES, P.A. - - �::),: X - �- / (f. . -� zt: - � Chad Simmons, PE Senior Project Manager Sewer Permit — Cover Letter MCGILL ASSOCIATES 5400 TRINITY ROAD, SUITE 107, RALEIGH, NC 27607/ 919.378,9111 / MCGILLASSOCIATES.COM (<�4� 7-r) er.:r � From: Chad Simmons chad.simmons@mcg4l ssociates.com Subject: [External] RE: Johnston County Detention Center fast track sewer extension application, WQ0041746 Date: Jul 10, 2020 at 10:11:03 AM To: Cashion, Ted ted.cashion@ncdenr.gov, ted.credle@smithfield-nc.com Cc: Robinson, Jason ,ason.t.robinson@ncdenr.gov, Deck, Erin M erin.deck@ncdenr.gov NEW, ;ictern-al email_ Do not click links or open attachments unless you %,crify. Send al! suspicious email as an attachment to Ted, Here's the missing data from Section V: Permit No.: NCO030716 Downstream Receiving Size: 8" System Wide Collection Permit No.: WQCS00270 Owner: Town of Smithfield The flow rate for staff was obtained from the MEP designer who referenced the ASPE (American Society of Plumbing Engineers) data handbooks for estimating sewage flows in buildings. Table 8-7 Typical Waste -Water Flows from Institutional Sources Waste -Water Flow, gpolunit (Lldfunit) Source Unit Range Typical Hospital, medical Bed 132.0-251.0 (500-950) 172.0 (650) Employee 5.3-15.9 (20-60) 10.6 (40) Hospital, mental Bad 79.3-172.0 (300-M) 106.0 (400) Employee 6.3-15.9 (20-60) 10.6 (40) Inmate 79.3-159.0 (300`600) 119.01450) Employ" 5.3-15.9 (20-60) 10.6 (40) Rest tome Resident 52.8-119.0 (200-450) 92.5 (350) Employee 5.3-15.9 120-60) 10.6 (40) School, day With cafeteria, gym, showers Student 15.9--W.4 (60-115) 21.1 (80) With cafeteria only Student 10,6-21.1 (40-80) 15.9 (60) Without cafeteria, gym, showers student 5.3-17.2 (20-65) 10.6 (40) School, boarding Student 52.8-106.0 (200-400) 74,0 (2W) Thanks, Fri Mcgili Shaping Communities Together _ m[�rgillassociates.coml Chad Simmons PE Project Manager McGill Associates, P.A. 5400 Trinity -Road, Suite 107, Raleigh, NC 27607 T 919.378,9111 c 919.810.1476 chad.simmons@mcgillassociates.com nc illassociates.com [mcQillassociates.comj From: Cashion, Ted �ted.cashion@ncdenr.apv> Sent: Saturday, June 27, 2020 10:27 AM To: ; Chad Simmons ¢chad.simmons@ mcgiilassociates.com> Cc: Robinson, Jason <jason.t.robinsan ncdenr.gQ >; Deck, Erin M <erin.deck@ ncdenr.ggY> Subject: Johnston County Detention Center fast track sewer extension application, WQ0041746 Hi Ted and Chad, We are reviewing the subject application and have a couple of items that need addressing. • Item V of the application must be completed. • In item V1.7, was the design flow rate of 10 gpd for institution staff obtained from the flow rates in 2T .0114? If so, which specific heading? Thanks, we'll continue drafting the permit upon submittal of this information. ted Ted Cashion Water Quality Regional Operations Division of Water Resources NC Department of Environmental Quality Raleigh Regional Office 919-791-4254 Cashion, Ted From: Cashion, Ted Sent: Saturday, June 27, 2020 10:27 AM To: ted.credle@smithfield-nc.com; chad.simmons@mcgillassociates.com Cc: Robinson, Jason; Deck, Erin M Subject: Johnston County Detention Center fast track sewer extension application, WQ0041746 Hi Ted and Chad, We are reviewing the subject application and have a couple of items that need addressing. - Item V of the application must be completed. - In item VI.7, was the design flow rate of 10 gpd for institution staff obtained from the flow rates in 2T .0114? if so, which specific heading? Thanks, we'll continue drafting the permit upon submittal of this information. ted Ted Cashion Water Quality Regional Operations Division of Water Resources NC Department of Environmental Quality Raleigh Regional Office 919-791-4254 ted.cashion(mncdenr.eov 1628 Mail Service Center Raleigh, NC 27699-1628 3800 Barrett Drive Raleigh, NC 27609 D,- E f DrWr.�snt of 4mrt�r.;n;a! pws, Subscribe to Collection System_& Sewer Permitting Updates Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties unless the content is exempt by statute or other regulation.