HomeMy WebLinkAbout660049_Compliance Evaluation Inspection_20200713Facility Number ® -
Visit: Com lance Inspection
for Visit: Routine 0 Comul
107Division of Water Resources
0 Division of Soil and Water Conservation
0 Other Agency
Operation Review 0 Structure Evaluation 0 Technical Assistance
0 Follow-up 0 Referral 0 Emercency 0 Other 0 Denied Access
Date of Visit: ? Arrival Time: Departure Time: County:
Farm Name: f u Je %L! s' Owner Email:
Owner Name:
Mailing Address:
Physical Address:
Facility Contact:
Onsite Representative: rA / (I , j
Certified Operator:
Back-up Operator:
Location of Farm:
Swine
Wean to Finish
Wean to Feeder
Feeder to Finish
Farrow to Wean
Farrow to Feeder
Farrow to Finish
Gilts
Boars
Other
Other
Phone:
Title:
Latitude:
Phone:
Integrator:
Certification Number:
Certification Number:
Design Current Design Current
Capacity Pop. Wet Poultry Capacity Pop.
La er
on -Layer
ets
Other
Poults
Design Current
Longitude:
Region:
Design Current
Cattle Capacity Pop.
Dairy Cow
Dairy Calf
Dairy Heifer
Dry Cow
Non -Dairy
Beef Stocker
Beef Feeder
Bccf Brood Cow
Discharges and Stream Impacts
1. Is any discharge observed from any part of the operation? ❑ Yes 2rNo ❑ NA ❑ NE
Discharge originated at: ❑ Structure ❑ Application Field ❑ Other:
a. Was the conveyance man-made? ❑ Yes �No
NA ❑ NE
b. Did the discharge reach waters of the State? (If yes, notify DWR) ❑ Yes ❑ NA ❑ NE
c_ What is the estimated volume that reached waters of the State (gallons)?
d, Does the discharge bypass the waste management system'! (If yes, notify DWR) ❑ Yes o ❑ NA ❑ NE
2. Is there evidence of a past discharge from any part of the operation? ❑ YCS4 No ❑ NA ❑ NE
3. Were there any observable adverse impacts or potential adverse impacts to the waters ❑ Ycs ❑ No ❑ NA ❑ NE
of the State other than from a discharge?
Page 1 of 3 21412015 Continued
Facili Number: - Date of Inspection: .f
Waste Collection & Treatment
4. is storage capacity (structural plus storm storage plus heavy rainfall) less than adequate? [] Yes No NA ❑ NE
a. If yes, is waste level into the structural freeboard? ❑ Yes 'o ❑ NA ❑ NE
Structure I Structure 2 Structure 3 Structure 4 Structure 5 Structure 6
Identifier:
Spillway?:
Designed Freeboard (in):
Observed Freeboard (in):
5. Are there any immediate threats to the integrity of any of the structures observed? ❑ Yes JeNo ❑ NA ❑ NE
(i.e., large trees, severe erosion, seepage, etc.)
6. Are there structures on -site which are not properly addressed and/or managed through a ❑ Yes No ❑ NA ❑ NE
waste management or closure plan?
If any of questions 4-6 were answered yes, and the situation poses an immediate public health or environmental hreat, notify DWR
7. Do any of the structures need maintenance or improvement? ❑ Yes VNo
❑ NA ❑ NE
8. Do any of the structures lack adequate markers as required by the permit? ❑ Yes ❑ NA ❑ NE
(not applicable to roofcd pits, dry stacks, and/or wet stacks)
9. Does any part of the waste management system other than the waste structures require ❑ Yes No ❑ NA ❑ NE
maintenance or improvement?
Waste Application
10. Are there any required buffers, setbacks, or compliance alternatives that need ❑ Yes 0 No ❑ NA ❑ NE
maintenance or improvement?
11. Is there evidence of incorrect land application? If yes, check the appropriate box below. ❑ Yes [?/No ❑ NA ❑ NE
❑ Excessive Ponding ❑ Hydraulic Overload ❑ Frozen Ground ❑ Heavy Metals (Cu, Zn, etc.)
❑ PAN ❑ PAN > 10% or 10 lbs. ❑ Total Phosphorus ❑ Failure to Incorporate Manure/Sludge into Barc Soil
❑ Outside of Acceptable Crop Window ❑ Evidence of Wind Drift ❑ Application Outside of Approved Area
12. Crop Typc(s): 1319,A h 5
13, Soil Type(s): I
14. Do the receiving crops differ from those designated in the CAWMP?
❑ Yes
L2 rhlo DNA
❑ NE
15. Does the receiving crop and/or land application site need improvement?
❑ Yes
❑ NA
NVN
❑ NE
16. Did the facility fail to secure and/or operate per the irrigation design or wettable
❑ Yes
❑ NA
❑ NE
acres determination?
17. Does the facility lack adequate acreage for land application?
❑ Yes
� ❑ NA
❑ NE
18. Is there a lack of properly operating waste application equipment?
❑ Yes
No ❑ NA
❑ NE
ReAuired Records & Documents
19. Did the facility fail to have the Certificate of Coverage & Permit readily available?
❑ Yes
❑ NA
❑ NE
20. Does the facility fail to have all components of the CAWMP readily available? If yes, check
❑ Yes
No ❑ NA
❑ NE
the appropriate box.
❑ WUP ❑Checklists ❑ Design ❑ Maps ❑ Lease Agreements ❑Other:
21. Does record keeping need improvement? If yes, check the appropriate box below. ❑ Yes o ❑ NA ❑ NE
❑ Waste Application ❑ Weekly Freeboard ❑ Waste Analysis ❑ Soil Analysis ❑ Waste Transfers ❑ Weather Code
❑ Rainfall ❑Stocking ❑ Crop Yield ❑ 120 Minute Inspections ❑ Monthly and V Rainfall Inspections Sludge Survey
22. Did the facility fail to install and maintain a rain gauge? ❑ Yes No ❑ NA ❑ NE
23. If selected, did the facility fail to install and maintain rainbreakers on irrigation equipment? ❑ Yes ❑ No ❑ NA ❑ NE
Page 2 of 3 21412015 Continued
Facility Number: - Date of Inspection:
24. Did the facility fail to calibrate waste application equipment as required by the permit? ❑ Yes eNo ❑ NA ❑ NE
25. Is the facility out of compliance with permit conditions related to sludge? If yes, check ❑ Yes a ❑ NA ❑ NE
the appropriate box(es) below.
❑ Failure to complete annual sludge survey ❑ Failure to develop a POA for sludge levels
❑ Non -compliant sludge levels in any lagoon
List structure(s) and date of first survey indicating non-compliance:
26. Did the facility fail provide documentation of an actively certified operator in charge? ❑ Yes VNo
❑ NA ❑ NE
27. Did the facility fail to secure a phosphorus loss assessments (PLAT) certification? ❑ Yes NA ❑ NE
Other Issues
28. Did the facility fail to properly dispose of dead animals with 24 hours and/or document ❑ Ycs No ❑ NA ❑ NE
and report mortality rates that were higher than normal?
29. At the time of the inspection did the facility pose an odor or air quality concern?
❑ Yes
❑ No
❑ NA
❑ NE
If yes, contact a regional Air Quality representative immediately.
30. Did the facility fail to notify the Regional Office of emergency situations as required by the
❑ Yes
❑ No
❑ NA
❑ NE
permit? (i.e., discharge, freeboard problems, over -application)
31. Do subsurface the drains exist at the facility? If yes, check the appropriate box below.
❑ Yes
❑ No
❑ NA
❑ NE
❑ Application Field ❑ Laboon/Sloragc Pond ❑ Other:
32. Were any additional problems noted which cause non-compliance of the permit or CAWMP?
❑ Yes
❑ No
❑ NA
❑ NE
33. Did the Reviewer/Inspector fail to discuss review/inspection with an on -site representative?
❑ Yes
❑ No
❑ NA
❑ NE
34. Does the facility require a follow-up visit by the same agency?
❑ Yes
❑ No
❑ NA
❑ NE
Comments (refer to question #): Explain any YES answers and/or any additional recommendations or any other comments.
Use drawings of facility to better explain situations (use additional pages as necessary).
J5to S L'L vQ_
Reviewer.'Inspeclor Name.,
Phone: � I q 7q l y L
Reviewerilnspector Signature_
Page 3 of 3
Date: 7 - f3 ;L a
21412015