1) Name of wastewater treatment plant to receive the wastewater:
Town of Fairmont WWTP
2) WWTP desiqn capacity 0.50 MGD
3) NPDES Permit No.: NC0021059 Expiration Date: 12 31 99
4) Compliance Information:
Present treatment plant performance
for previous 12 months - beginninq N A IMS is not presently
operating !
(See attached self-monitorinq data)
5) Quantity and type of wastewater from proposed sewers:
56.455 GPD
domestic 100q ; industrial other
6) Volume from previously approved projects not yet tributary to
WWTP 0 GPD
7) Regional Recommendations: Approval X Denial
RR/rr
Enclosure
State of North Carolina
Department of Environment
and Natural Resources
Division of Water Quality
James B. Hunt, Jr., Governor
Wayne McDevitt, Secretary
A. Preston Howard, Jr., P.E., Director
September 8, 1998
Mr. Bill Hill, Town Manager
Town of Fairmont
P.O. Box 248
Fairmont, North Carolina 28340
NCDENR
NORTH CAROL
ENVIRONMENT ANT1M V
c, r::'• 5 1998
I=AYP T EViLLE
EG
Subject: Application No. WQ0015831
Annexation for Town of Fairmont
Sewers -Public
Robeson County
Dear Mr. Hill:
The Division's Permits and Engineering Unit acknowledges receipt of your permit application and
supporting materials on September 8, 1998. This application has been assigned the number listed above.
Your project has been assigned to Mr. Ed Buchan for a detailed engineering review. Should there be any
questions concerning your project, the reviewer will contact you with a request for additional information.
Be aware that the Division's Regional Office, copied below, must provide recommendations from the
Regional Supervisor or a Procedure Four Evaluation for this project, prior to final action by the division.
If you have any questions, please contact Mr. Ed Buchan at 919/733-5083 ext. 546. If the engineer is
unavailable, you may leave a message on their voice mail and they will respond promptly.
PLEASE REFER TO THE ABOVE APPLICATION NUMBER WHEN MAKING INQUIRES ON
THIS PROJECT.
Sincerely,
Mr. Kim H. Colson, P.E.
Supervisor, Non -Discharge Permitting Unit
lc . Fayetteville Regional Office, Water Quali
-Hobbs, Upchurch & sociate r A.
P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015 FAX 919-733-2496
An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper
I.
FI-4
psp
State of North Carolina
Department of Environment, Health, and Natural Resources
Division of Environmental Management
Non -Discharge Permit Application
(THIS FORM MAYBE PHOTOCOPIED FOR USE AS AN ORIGINAL)
GRAVITY SEWER EXTENSION
PUMP STATIONS, AND PRESSURE SEWERS
GENERAL INFORMATION:
1. Applicant (corporation, individual, or other): Town of Fairmont
2. Print Owners or Signing Official's Name and Title (the person who is legally
responsible for the facility and its compliance): Ben Hill, Town Manager
j 3. Mailing Address: P.O. Box 248
City: Fairmont State: NC Zip: 28340
Telephone No.: 9( 10 ) 628 - 9766
4. Project Name (subdivision, facility, or establishment name - should be consistent with project
name on planstspecs., letters of flow acceptance, Operational Agreements, etc.):
Annexation Sewer Improvements
5. Application Date: 7/31/98 6. Fee Submitted: $ 400.00
7. County where project is located: Robeson
PERMIT INFORMATION:
1. Permit No. (will be completed by DEM):
2. Specify whether project is: X new; renewal*; modification.
*If renewal, complete only sections I through III and applicant signature (on
pg.9). Submit only pgs. 1, 2, 9 (original and 3 copies of each). Engineer signature not
required for renewal.
3. If this application is being submitted as a result of a renewal or modification to an existing permit,
list the existing permit number and issue date
4. Specify whether the applicant is X public or private.
FORM GSEA 4/91 Page 1 of 10
GRAVITY SEWER EXTENSION & PUMP STATION
PAGE 2 OF 10 (4/91)
III. INFORMATION ON WASTEWATER:
1. Nature of Wastewater: 100 % Domestic; % Commercial;
% Industrial; % Other waste (specify
2. Please provide a one or two word description specifying the origin of the wastewater, such as
school, subdivision, hospital, commercial, industrial, apartments, etc.:
Wastewater generated by this project comes from four areas that the Town has annexed. All
wastewater generated is expected to be domestic in nature
3. Indicate any parameter (and its concentration) that will be greater than normal domestic levels:
N/A
4. If wastewater is not domestic in nature, what level of pretreatment has been provided to ensure
protection of the receiving wastewater treatment facility?
N/A
5. Volume of wastewater generated by this project: 56,455 gallons per day
6. Explanation of how wastewater volume was determined: (128 homes x 360 gpd) + (Restaurant
with 50 seats x 40 gal./seat) + (Residental Care Facility with 125 x 60 gal./person) + (5 other
businesses with 35 total employees x 25 gal./employee) = 56,455 gallons per day
IV. DESIGN INFORMATION:
1. Brief project description: Installation of approximately 18,000 LF of gravily sewer and two
pumRstations to serve four annexed areas
2. Name of wastewater treatment facility receiving wastewater: Town of Fairmont WWTP
a. Facility permit no.: WO 0012541
b. Engineer should provide statement of his evaluation of downstream sewers to accept
the wastewater: Down stream sewers are designed to accept proposed flow
2of10
GRAVITY SEWER EXTENSION & PUMP STATION
PAGE 3 OF 10 (4/91)
3. Summary of sewer pipe by diameter size and pipe material. Indicate here whether C factor or N
factor is used and circle C or N below: N
Dia.
Length
Pipe
N
Min.
Max.
Minimum
Max.
Minimum
(In.)
(Lin. Ft)
Material
Factor
Slope %
Slope %
Velocity (fps)
Vel. (fps)
Cover (ft.)
8
15,542
PVC
0.010
0.40
3.60
2.84
8.53
3.0
8
504
DIP
0.013
0.40
1.30
2.19
3.94
2.0
10
360
PVC
0.010
0.28
0.28
2.76
2.76
3.0
10
875
DIP
0.013
0.28
0.28
2.12
2.12
1.0
12
925
PVC
0.010
0.22
0.22
2.76
2.76
3.0
NOTE: The minimum velocity must not be less than 2 fps.
For public sewers the minimum diameter is 8 inches.
4. Anchors shall be provided for sewers with slopes greater than 20 %. The anchor
spacing shall be as follows:
a. 36 feet separation for slopes of 21 % to 35%;
b. 24 feet separation for slopes of 36% to 50%.
c. 16 feet separation for slopes of 50% and greater.
For velocities greater than 15 fps, it is strongly recommended that measures be
considered which will protect the sewers and manholes from erosion. For velocities
greater than 20 fps, erosion control measures must be specified.
For any excessive slopes or velocities that will occur in any sewer line segment, what
measures have been taken to protect the sewer pipe and manholes?
N/A
5. Maximum sewer reach length between manholes 425 linear feet.
6. This sewer line segment occurs between manhole no. several sew and manhole no._
7. Does the owner/operator have the ability to clean this length? X Yes No.
8. Sewer subject to existing or planned traffic bearing loads? X Yes No.
If yes, what measures are being taken to enable the sewers to withstand the loads?
Use of ductile iron pine and minimum b= Mguirements
9. Outside drop manholes are provided where invert separations exceed: 2.5 feet.
10. Identify (by manhole number) those manholes that have drop connections: 30,22,29,49
3of10
GRAVITY SEWER EXTENSION & PUMP STATION
PAGE 4 OF 10 (4/91)
11. Maximum allowable infiltration/exfiltration test rate:
Note: Must not exceed 200 GPD/pipe dia. in./mile. 100 GPD/pipe dia. in./mile.
12. Minimum separation distances as shown on the plans or addressed in the specifications:
a) 100 ft. horizontal separation from wells or other water supplies? X Yes _ No
b) 12 in. vertical separation from storm sewer or ferrous pipe
sanitary sewer specified?
c) 10 ft. horizontal separation from water mains or 18 in. vertical
separation (water or sewer) ferrous pipe specified?
13. Are manholes subject to flooding?
14. If yes, are manhole rim elevations 1 foot above 100-year flood level,
(100 year flood elevation should be indicated on plans)
15.Or are manholes watertight and vented 1 foot above the 100-year
flood elevation (should be shown on plans):
16. Identify (by manhole number) those manholes that are vented:
X Yes No
X Yes No
_Yes X No
Yes _No
_Yes No
17. Does this project involve any stream crossings? _yes X no. If yes, what precautions or
special features have been utilized to ensure protection of the sewer line and not restrict stream
flow? Identify the sheet of the plans and station number where stream crossings are located: -
4of10
GRAVITY SEWER EXTENSION & PUMP STATION
PAGE 5 OF 10 (4/91)
V. PUMP STATION INFORMATION
1. Pump Station No: 1 (A separate sheet V.1 through V.15 should be submitted for each pump
station)
2. Name of closest downslope surface waters: Old Field Swamp
3. Classification of closest downslope surface waters: C Sw (as established by the
Environmental Management Commission & specified on page 6 of this applic.).
4. If a power failure at this pump station could impact waters classified as WS, SA, B, or SB,
describe which of the measures are being implemented to prevent such impact, as required in
15A NCAC 2H.0200: Generator to be provided
5. What size pumps are provided? 180 GPM
6. How many pumps are provided? 2
7. / What is the maximum capacity of the pump station? 259,200 GPD
8. What is the design total dynamic head? 67 feet
9. How many pump cycles will occur at the design flow rate? 5 cycles per hour
10. Check if provided at pump station:
Alternate Power Source
Wet Well Vented with Screen
Fillets in Wet Well
Check Valves and Gate Valves
Security Fencing
Lockable Wet Well Cover
X
X
X
X
X
X
Area Light X
110V Electrical Convenience Outlet X
Flood/Buoyancy Protection X
High Water Alarm Audible and Visual X Auto Dialer
11. Summary of force main (by diameter size and pipe material):
Diameter
Length
Pipe
(Inches)
(Linear Ft)
Material
6
7,404
PVC
6
429
DIP
High
Elevation
102.00
Low
Elevation
94.00
Minimum Maximum Minimum
Velocity (fps)
2.05
102.00 94.00 2.05
Vel. (fps) Cover (in)
2.05 36
2.05 36
12. Are air release valves provided at all high points along the force main (must be provided where the
elevation difference exceeds 10 feet)? X yes no
13. Is pump station subject to flooding? _des X no. If yes, what measures are
being taken to protect against flooding?
14. If subject to flooding, specify the 100-year flood elevation: Feet MSL
15. Are there existing or planned pump stations downstream of this station? X yes no
5of10
GRAVITY SEWER EXTENSION & PUMP STATION
PAGE 7 OF 10 (4/91)
DIVISION OF ENVIRONMENTAL MANAGEMENT REGIONAL OFFICES (4/91)
Ashville Regional WQ Super.
Washington Regional WQ Super.
Raleigh Regional WQ Super.
59 Woodfin Place
P O Box 1507
3800 Barrett Dr., Suite 101
Asheville, NC 28802
Washington, NC 27889
Raleigh, NC 27609
704/251-6208
919/946-6481
919/733-2314
Avery
Macon
Beaufort
Jones
Chatham Nash
Buncombe
Madison
Bertie
Lenoir
Durham Northampton
Burke
McDowell
Camden
Martin
Edgecombe Orange
Caldwell
Mitchell
Chowan
Pamlico
Franklin Person
Cherokee
Polk
Craven
Pasquotank
Granville Vance
Clay
Rutherford
Currituck
Perquimans
Halifax Wake
Graham
Swain
Dare
Pitt
Johnston Warren
Haywood
Transylvania
Gates
Tyrell
Lee Wilson
Henderson
Yancy
Greene
Washington
Jackson
Hertford
Wayne
Hyde
Fayetteville Regional WQ Super.
Mooresville Regional WQ Super.
Wilmington Region. WQ Super.
Wachovia Building, Suite 714
919 North Main Street
127 Cardinal Drive Extension
Fayetteville, NC 28301
Mooresville, NC 28115
Wilmington, NC 28405-3845
91p/486-1541
704/663-1699
919/395-3900
Anson
Moore
Alexander
Mecklenburg
Brunswick New Hanover
Bladen
Robeson
Cabarrus
Rowan
Carteret Onslow
Cumberland
Richmond
Catawba
Stanly
Columbus Pender
Harnett
Sampson
Gaston
Union
Duplin
Hoke
Scotland
Iredell
Cleveland
Montgomery
Lincoln
Winston-Salem Regional WQ Super.
8025 North Point Boulevard, Suite 100
Winston-Salem, NC 27106
919/761-2351
Alamance
Rockingham
Alleghany
Randolph
Ashe
Stokes
Caswell
Surry
Davidson
Watauga
Davie
Wilkes
Forsyth
Yadkin
Guilford
7of10
GRAVITY SEWER EXTENSION & PUMP STATION
PAGE 8 OF 10 (4/91)
THE APPLICATION PACKAGE WILL NOT BE ACCEPTED BY THE
DIVISION OF ENVIRONMENTAL MANAGEMENT UNLESS ALL OF
THE APPLICABLE ITEMS ARE INCLUDED WITH THE SUBMITTAL
Required Items
a. One original and three copies of the completed and appropriately executed application form.
b. Three sets of detailed plans and specifications signed and sealed by a North Carolina Professional
Engineer. The plans must include a general location map, a plan view of the sewer extension, a
profile of the sewer extension, a profile of the sewer extension, details on the pump station, and
must show the proximity of the sewer extension to other utilities and natural features.
Specifications may be omitted for delegated authorities. Each sheet of the plans and the first page
of the specifications must be signed and sealed. Three copies of the existing permit if a renewal or
modification.
C. Three copies of all calculations, including pump selection, friction calculations, cycle time, pump
curves (including system curves applicable with one pump running, two pumps running, three
pumps running, etc.), and evaluation of downstream pump stations. These items must be
submitted under the signature and seal of the North Carolina Professional Engineer.
d. The appropriate permit processing fee, in accordance with 15A NCAC 2HO205 (c)(5).
e. If the owner/authority of the wastewater treatment facility (WWTF) that will be accepting the
wastewater flow from this project is different from the applicant of the project, then a letter must
be provided from the owner/authority of the WWTF specifying the volume of flow that will be
accepted. The letter should be a recent letter and should refer to the project by the same name as
that identified on the application and the plans/specifications.
f. An Operational Agreement (original and two copies) must be submitted if the sewer extension will
be serving single family residences, condominiums, mobile homes, or town houses and if the
subject sewer extension is owned by the individual residents, a homeowners association, or a
developer.
8of10
GRAVITY SEWER EXTENSION & PUMP STATION
PAGE 9 OF 10 (4/91)
Name and Complete Address of Engineering Firm: Hobbs, Upchurch & Associates, P.A., 290 S.W. Broad Street,
P.O. Box 1737
City: Southern Pines State: NC Zip: 28388
Telephone Number: ( 910 ) 692-5616
Professional Engineer's Certification:
I, , attest that this application for Town of Fairmont -
Annexation Sewer Improvements has been reviewed by me and is accurate and complete to
the best of my knowledge. I further attest to the best of my knowledge the proposed design has been prepared in accordance
with the applicable regulations. Although certain portions of this submittal package may have been developed by other
professional, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have
judged it to be consistent with the proposed design..
North Carolina Professional Engineer's Registration No. 22989
Print Name of Engineer William R. Buie P.E.
.CARON���''%
Seal and Signature (specify date): =.�OFESSIpN99 l�`JOC�+�►"\
l•
J SEAL
14 22989 _ 8.25 •98
Applicant's Certification: ��'�<<IAM
I, Ben Hill, Town Manager, attest that this application for Town of Fairmont, Annexation Sewer Improvements has
been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this
application are not competed and that if all required supporting information and attachments are not included, this application
package will be returned to me as incomplete.
Signature—&—�-Q Date
THE COMPLETED APPLICATION PACKAGE, INCLUDING ALL SUPPORTING INFORMATION AND
MATERIALS, SHOULD BE SENT TO THE FOLLOWING ADDRESS:
NORTH CAROLINA DIVISION OF ENVIRONMENTAL MANAGEMENT
WATER QUALITY SECTION
PERMITS AND ENGINEERING UNIT
POST OFFICE BOX 29535
RALEIGH, NORTH CAROLINA 27626-0535
TELEPHONE NUMBER: (919) 733-5083
9of10
PERMIT APPLICATION PROCESSING FEES
(effective October 1,1990)
GRAVITY SEWER EXTENSION & PUMP STATION
PAGE 10 OF 10 (4/91)
CATEGORY NEW APPLICATIONS/ RENEWALS WITHOUT
MODIFICATIONS MODIFICATIONS
> 1,000,000 GPD
Industrial $400 $300
Domestic/Cooling Water $400 $300
10,001 - 1,000,000 GPD
Industrial $400 $250
Domestic/Cooling Water $400 $250
1,001 - 10,000 GPD
Industrial $400 $200
;Domestic/Cooling Water $400 $200
<or =1,000 GPD and
Single Family Dwelling $240 $120
Sludge < or = 300 Acres $400 $250
Sludge > 300 Acres $400 $250
Sewer Extensions
(nondelegated) $400 0
Sewer Extensions
(delegated) $200 0
Closed -Loop Recycle
or Evaporative $400 $200
NOTE: The Fees for Soil Remediation Projects are the same as for Sludges.
Under the Sewer Extension Fee, "delegated to municipalities" applies only to those
governmental jurisdictions that have specific delegation review authority, as granted by the
Division of Environmental Management.
10 of 10
GRAVITY SEWER EXTENSION & PUMP STATION
PAGE 5 OF 10 (4/91)
V. PUMP STATION INFORMATION
1. Pump Station No: 2 (A separate sheet V.1 through V.15 should be submitted for each pump
station)
2. Name of closest downslope surface waters: Old Field Swamp
3. Classification of closest downslope surface waters: C Sw (as established by the
Environmental Management Commission & specified on page 6 of this applic.).
4. If a power failure at this pump station could impact waters classified as WS, SA, B, or SB,
describe which of the measures are being implemented to prevent such impact, as required in
15A NCAC 2H.0200: Generator to be provided
5. What size pumps are provided? 180 GPM
6. How many pumps are provided? 2
7. What is the maximum capacity of the pump station? 259,200 GPD
8. What is the design total dynamic head? 66 feet
9. How many pump cycles will occur at the design flow rate? 3 cycles per hour
10. Check if provided at pump station:
Alternate Power Source
Wet Well Vented with Screen
Fillets in Wet Well
Check Valves and Gate Valves
Security Fencing
Lockable Wet Well Cover
X
X
X
X
X
X
Area Light X
110V Electrical Convenience Outlet X
Flood/Buoyancy Protection X
High Water Alarm Audible and Visual X Auto Dialer
11. Summary of force main (by diameter size and pipe material):
Diameter Length Pipe High Low
(Inches) (Linear Ft) Material Elevation Elevation
4 1,014 PVC 102.50 93.50
Minimum Maximum Minimum
Velocity (fps) Vel. (fps) Cover (in)
4.60 4.60 36
12. Are air release valves provided at all high points along the force main (must be provided where the
elevation difference exceeds 10 feet)? X yes no
13. Is pump station subject to flooding? _yes X no. If yes, what measures are
being taken to protect against flooding?
14. If subject to flooding, specify the 100-year flood elevation: Feet MSL
15. Are there existing or planned pump stations downstream of this station? _X__yes no
5of10
PUMP STATION DESIGN WORKSHEET
PROJECT:
LOCATION:
HUA NO.:
DATE:
DESIGN PARAMETERS
AVERAGE DAILY FLOWRATE =>
PEAK FLOWRATE =>
FORCE MAIN LENGTH =>
MAX FORCE MAIN SIZE =>
SELECTED FORCE MAIN SZ. =>
FLUID HP AT 50% EFF. =>
SYSTEM WORKS
MAX ELEVATION =>
MIN ELEVATION =>
STATIC LIFT =>
FITTING LOSS =>
STATION LOSS =>
EQUIV. LENGTH OF PIPE =>
FRICTION COEFF. =>
PUMP SELECTION
PUMP TYPE =>
PUMP SIZE =>
IMPELLER SIZE =>
DIST. FROM INV. TO INTAKE =>
FLOAT SETTING
WET WELL DIA =>
WET WELL INV =>
PUMP OFF =>
CYCLES PER HOUR =>
CURVE PUMP RATE =>
ACTUAL MAX FRC. MAIN SZ.=>
NECESSARY CAPACITY =>
EMERGENCY CAPACITY =>
PUMP ON TIME =>
PUMP OFF TIME =>
CYCLE TIME =>
ELEVATION SUMMARY
WET WELL INV =>
PUMP OFF =>
LEAD ON =>
LAG ON =>
ALARM =>
RIM =>
STA. EMERGENCY CAP. =>
NC 130 Pump Station
Fairmont, North Carolina
FR9606
23-Jul-98
14
28
7833
2.39
6
1
102.00
94.03
7.97
20
30
7853
120
Suction -Lift
7.50
8.500
18.00
6
81.00
82.50
5
180
6.06
80
6720
1.76
11.32
13.09
81.00
82.50
84.00
84.75
85.25
97.03
3073
(GPM)
(GPM)
(FT)
(IN)
(IN)
(HP)
(ELEV)
(ELEV)
(FT)
(FT)
(FT)
(FT)
(PVC)
(HP)
(IN)
(IN)
(FT)
(ELEV)
(ELEV)
(EA)
(GPM)
(IN)
(GAL)
(GAL)
(MIN)
(MIN)
(MIN)
(ELEV)
(ELEV)
(ELEV)
(ELEV)
(ELEV)
(ELEV)
(GAL)
Town of Fairmont
SYSTEM CURVE
FLOW
VEL HD
FRICT HD
TDH
(GPM)
(FT)
(FT)
(FT)
0
0.000
0.00
38
5
0.000
0.04
38
10
0.000
0.14
38
15
0.000
0.29
38
20
0.001
0.49
38
25
0.001
0.74
39
30
0.002
1.04
39
35
0.002
1.38
39
40
0.003
1.77
40
45
0.004
2.20
40
50
0.005
2.67
41
55
0.006
3.18
41
60
0.007
3.74
42
65
0.008
4.34
42
70
0.010
4.97
43
75
0.011
5.65
44
80
0.013
6.37
44
85
0.014
7.12
45
90
0.016
7.92
46
95
0.018
8.75
47
100
0.020
9.62
48
105
0.022
10.53
49
110
0.024
11.48
49
115
0.026
12.46
50
120
0.029
13.48
51
125
0.031
14.54
53
130
0.034
15.63
54
135
0.036
16.76
55
140
0.039
17.93
56
145
0.042
19.13
57
150
0.045
20.37
58
155
0.048
21.65
60
160
0.051
22.95
61
165
0.054
24.30
62
170
0.058
25.68
64
175
0.061
27.09
65
185
0.068
30.03
68
190
0.072
31.55
70
195
0.076
33.10
71
200
0.080
34.69
73
205
0.084
36.31
74
210
0.088
37.96
76
PUMP STATION DESIGN WORKSHEET
Town of Fairmont
PROJECT:
NC 41 North Pump
Station
LOCATION:
Fairmont, North Carolina
HUA NO.:
FR9606
SYSTEM CURVE
DATE:
23-Jul-98
FLOW
VEL HD FRICT
HD
TDH
(GPM)
(FT)
(FT)
(FT)
DESIGN PARAMETERS
AVERAGE DAILY FLOWRATE _>
7
(GPM)
0
0.000
0.00
39
PEAK FLOWRATE _>
18
(GPM)
5
0.000
0.04
39
FORCE MAIN LENGTH =>
1014
(FT)
10
0.001
0.13
39
MAX FORCE MAIN SIZE _>
1.92
(IN)
15
0.002
0.27
39
SELECTED FORCE MAIN SZ. _>
4
(IN)
20
0.004
0.46
39
FLUID HP AT 50% EFF. _>
1
(HP)
25
0.006
0.70
40
30
0.009
0.98
40
SYSTEM WORKS
35
0.012
1.31
40
MAX ELEVATION =>
102.50
(ELEV)
40
0.016
1.68
41
MIN ELEVATION =>
93.50
(ELEV)
45
0.020
2.08
41
STATIC LIFT =>
9
(FT)
50
0.025
2.53
42
FITTING LOSS =>
20
(FT)
55
0.031
3.02
42
STATION LOSS =>
30
(FT)
60
0.036
3.55
43
EQUIV. LENGTH OF PIPE _>
1034
(FT)
65
0.043
4.11
43
FRICTION COEFF. _>
120
(PVC)
70
0.050
4.72
44
75
0.057
5.36
44
PUMP SELECTION
80
0.065
6.04
45
PUMP TYPE _>
Suction -Lift
85
0.073
6.76
46
PUMP SIZE _>
7.50
(HP)
90
0.082
7.51
47
IMPELLER SIZE _>
8.500
(IN)
95
0.091
8.30
47
DIST. FROM INV. TO INTAKE _>
18.00
(IN)
100
0.101
9.13
48
105
0.112
9.99
49
FLOAT SETTING
110
0.122
10.89
50
WET WELL DIA =>
6
(FT)
115
0.134
11.82
51
WET WELL INV =>
86.00
(ELEV)
120
0.146
12.79
52
PUMP OFF =>
87.50
(ELEV)
125
0.158
13.79
53
CYCLES PER HOUR =>
3
(EA)
130
0.171
14.83
54
CURVE PUMP RATE _>
180
(GPM)
135
0.184
15.90
55
ACTUAL MAX FRC. MAIN SZ.=>
6.06
(IN)
140
0.198
17.01
56
NECESSARY CAPACITY =>
180
(GAL)
145
0.213
18.15
57
EMERGENCY CAPACITY =>
3360
(GAL)
150
0.228
19.32
59
PUMP ON TIME _>
1.76
(MIN)
155
0.243
20.53
60
PUMP OFF TIME _>
17.62
(MIN)
160
0.259
21.77
61
CYCLE TIME _>
19.38
(MIN)
165
0.276
23.05
62
170
0.293
24.36
64
ELEVATION SUMMARY
175
0.310
25.70
65
WET WELL INV =>
86.00
(ELEV)
PUMP OFF =>
87.50
(ELEV)
185
0.346
28.48
68
LEAD ON =>
89.00
(ELEV)
190
0.365
29.92
69
LAG ON =>
89.50
(ELEV)
195
0.385
31.40
71
ALARM =>
90.50
(ELEV)
200
0.405
32.90
72
RIM =>
98.40
(ELEV)
205
0.425
34.44
74
STA. EMERGENCY CAP. _>
2305
(GAL)
210
0.446
36.01
75
8-27-1998 10:54AM FROM P.6
GRAVITY SEWER EXTENSION & PUMP STATION
PAGE 6 OF 10 (4/91)
TO: REGIONAL WATER QUALITY SUPERVISOR
Please provide me with the classification of the surface waters identified in number 5 below and on the
attached map segment:
Name of surface waters: Old Field Swam
Classification (as established by the Environmental Management Commission): C Sw
Proposed Classification, if applicable: N/A
Signature of regional officepersonnel:
INSTRUCTIONS TO ENGINEER
In order to determine whether provisions for dual or standby power may be required for the subject facility,
the classification of the closest downslope surface waters (the surface waters that any overflow from the facility
would flow toward) must be determined. You are required to submit this form, with items 1 through 10
completed, to the appropriate Division of Environmental Management Regional Water Quality Supervisor (see
attached listing). At a minimum, you must include an 8.5" by I V copy of the portion of a 7.5 minute USGS
Topographic Map which shows the subject surface waters. You must identify the location of the facility and the
closest downslope surface waters (waters for which you are requesting the classification) on the submitted map
copy. The application may not be submitted until this form is completed and included with the submittal.
l . Applicant (corporation, individual, or other): Town of Fairmont
2. Name and Complete Address of Engineering Firm: Hobbs. Uochurch & Associates P.A.
290 S.W. Broad Street P.O. Box 1737
City: Southern Pines State: NC Zip: 28388
Telephone No.1910) 692-5616
3. Project Name: Town of Fairmont — Annexation Sewer Improvements
4. Pump station design flow: 259.200 GPD; 180 GPM
S. Name of closest downslope surface waters: Old Field Swamp
6. County(s) where project and surface waters are located: Robeson
7. Map name and date: Southwest Lumberton, NC USGS Map 1962
8. North Carolina Professional Engineer's Registration No. 22989
9. Print Name of Engineer William R. Buie
10. Seal and Signature (specify date):
: SEAL '
- s 22989
i
6 of 10
"04" </AM++ + r`��
Ld c0ouk". -e. 5"
8.25.16
8-27-1998 10:5AAM FROM 1 P-7
/f
�•
140
Ic
sp � 0 ,, .,:Preratt , �.• ' 4:
1, �\: f- I \ `y-` .� � �- ..• y _ .e �+ (•` �_,
so
ilk j
,1•� ' * di o over
421
�---•_--zya�zs.��y C_e���� met \ �o II \. •i. \ d , � `\
cc
utKtatio \�y / . ��a • = • se / Cll • I , / �: �' G
47
_': `• _ - i ' 1\ -_ l;(. r 5 f• ' t side
��... -���' ` •" \ 1 - �.\�• �J �� Park _ ;�=' �::. ;=d •ik \ � � •\
led7'30„ •' •73 LAKE VIEW. S. C.17 MF• 1 970000 FEET 675 5' 67
Mapped, edited, and published by the Geological Survey
Control by USGS. NOS/NOAA. and North Carolina Geodetic Survey ,•
M N 1000 0;
i opography by photogrammetric methods from aerial I- ck
8-27-1998 10:55AM FROM
P_ 8
GRAVITY SEWER EXTENSION & PUMP STATION
PAGE 6 OF 10 (4/91)
TO: REGIONAL WATER QUALITY SUPERVISOR
Please provide me with the classification of the surface waters identified in number 5 below and on the
attached map segment:
Name of surface waters: Old Field Swamp
Classification (as established by the Environmental Management Commission): C Sw
Proposed Classification, if applicable: N/A
Signature of regional office personnel: 9L-1 R Z,-� Date: 'q. Z7 - 9 S
INSTRUCTIONS TO ENGINEER
In order to determine whether provisions for dual or standby power may be required for the subject facility,
the classification of the closest downslope surface waters (the surface waters that any overflow from the -facility
would flow toward) must be determined. You are required to submit this form, with items 1 through 10
completed, to the appropriate Division of Environmental Management Regional Water Quality Supervisor (see
attached listing). At a minimum, you must include an 8.5" by 11" copy of the portion of a 7.5 minute USGS
Topographic Map which shows the subject surface waters. You must identify the location of the facility and the
closest downslope surface waters (waters for which you are requesting the classification) on the submitted map
copy. The application may not be submitted until this form is completed and included with the submittal.
1. Applicant (corporation, individual, or other): Town of Fairmont
2. Name and Complete Address of Engineering Firm: Hobbs. Upchurch & Associates P A
290 S.W. Broad Street. P.O. Box 1737
City: Southern Pines State: NC Zip: 28388
Telephone No. _(910) 692-5616
3. Project Name: Town of Fairmont — Annexation Sewer Improvements
4. Pump station design flow: 259,200 GPD; 180 GPM
5. Name of closest downslope surface waters: Old Field Swam
6. County(s) where project and surface waters are located:_ Robeson
7. Map name and date: Fairmont- NC USGS MAR 1962
8. North Carolina Professional Engineer's Registration No. 22989
9. Print Name of Engineer William R. Buie
10. Seal and Signature (specify date):
CAR0l�4,
of O� S'�•S
i a SEAL
• 2298 i
t �d
6 of 10 '%,�'It/AM lk
B•25.48
LA.V0 (U.S. 2dr) 13 j,.17, `.
4 If
p, 10
I
.1 M, 0D
'V4 v IR
to17
>
'41
Cy
pl:
N
• [INC i;-Mv 0
t to
o 11
t
ell, 4, o J0
L
N.
"n
X Q� 7
JA I r
j
71 qNd
t
It Xk
/*
0/4.
tit' r
I�
L
+
fl/
to
+ '1611, "' , nZ. T V
Io! fj, t11 RZ +
--- ut
E IIf
to it IS
SMA It,
0
ft I
Al
Nf\1
+ I
r--A to
Nfl.;
.�
ri
IA
T
+ to
S4,
'2
JI
-W* v.
V.
oil
J\
# % �tj�
t