HomeMy WebLinkAboutSW7060405_HISTORICAL FILE_20060519STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW��� DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS HISTORICAL FILE DOC DATE�� aJ YYYYMMDD Thomas Engineering, PA 403-C Airport Road P. O. Box 1309, New Bern, NC 28563 252.637.2727 fax:252.636.2448 email: jthomas744@aol.com FEDERAL EXPRESS Tracking # 7921 0114 2914 To: Stormwater Management Section Division of Water Quality 943 Washington Square Mail Washington, NC 27889 Attn: Roger Thorpe Re: Stormwater Plan Tucker Creek Townes Havelock, Craven County 2001-023 Dear Roger, May 17, 2006 mAY 19 2006 DWQ-WARD Please find enclosed two copies of the Revised Stormwater Management Plan drawings per your comment letter dated May 11, 2006for the referenced project for your approval. In regards to the comment on the vegetative shelf, we feel that for the size pond, six feet of shelf is adequate and to increase the width of the shelf to 10 feet would significantly reduce the volume of the pond. At the present design of 6 feet, the shelf width is more than what would be proportional to the pond surface area when considering a 10 foot shelf for a pond of/z acre or so. If you have any questions or comments, please do not hesitate to call. I hope you are doing well. Since y, ohr� G. Thomas, P.E. Encl Cc wlencl: Patrick McCullough Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources May 11, 2006 Mr. Patrick McCullough Tucker Creek Townes, LLC 604 East Main Street Havelock, NC 28532 Subject: Stormwater Review SV 7060405 Tucker Creek Townes Craven County Dear Mr. McCullough: Alan W. Klimek, P.E. Director Division of Water Quality This office received a Coastal Stormwater permit application and plans for the subject project on April 11, 2006, A preliminary review of your project indicates that before a State Stormwater permit can be issued the following additional information is needed: The plan detail of the wet pond outlet does not give the size of the small diameter orifice. Please correct. The 6:1 vegetated shelf around the wet pond should be at least 10 feet wide. If this cannot be provided please explain. 3. There is a cross section labeled "Z — Z" on page 3 of 3 of the plans. I cannot find "Z — Z" on page 2 of 3. The above requested information must be received in this office prior to June 11, 2006 or your applications will be returned as incomplete. The return of these projects will necessitate resubmittal of all required items including the application fees. If you need additional time to submit the required information, please mail or fax your request for time extension to this office at the Letterhead address. You should also be aware that the Stormwater Rules require that the permit be issued prior to any development activity. Construction without a permit is a violation of 15A NCAC 2H.1000 and• North Carolina General Statute 143-2151 and may result in civil penalties of up to $25,000 per day. If you have questions, please feel free to contact me at (252) 948-3923. /Sincerely, Roger K. Thorpe Environmental Engineer Washington Regional Office cc: Thomas Engineering, PA Washington Regional Office North Carolina Division of Water Quality Internet: www.ricwatercigality.org One 943 Washington Square Mall Phone (252) 946-6481 NorthCaroiina Washington, NC 27889 Fax (252) 946-9215 Natumllry An Equal Opportunity/Affirmative Action Employer— 50% Recycled110% Post Consumer Paper �/A Thomas Engineering, PA 403-C Airport Road P. O. Box 1309, New Bern, NC 28563 252.637.2727 fax:252.636.2448 email: jthomas744@aol.com FEDERAL EXPRESS Tracking # 7927 1002 0517 To: Stormwater Management Section Division of Water Quality 943 Washington Square Mall Washington, NC 27889 Attn: Roger Thorpe Re: Stormwater Plan Tucker Creek Townes Havelock, Craven County 2001-023 Dear Roger, RECEO E APR ? 1 2006 DWQ-WARO April 10, 2006 Please find enclosed the Stormwater Management Plan Submittal for the referenced project for your approval. Enclosed items include the original Stormwater Management Permit Application Form and one copy, the original Wet Detention Basin Supplement and one copy, and two copies each of the Stormwater Report and Plans along with check # 6164 in the amount of $ 420.00 for the Stormwater Permit Fee. I have also attached the compliance sheet from DWQ concerning the area marked on the plans as exempt from the Neuse River Buffer Rules. If you have any questions or comments, please do not hesitate to call. I hope you are doing wev Sing6rely . Thomas, P.E. Cc w/encl: Patrick McCullough rUNK ew O NORTH CAROLINA DEPARTMENT OF COPY 1.1 2006 ENVIRONMENT AND NATURAL RESOURCES �� DiVLSION OF WATER QIIAiITY �1 uVVQ_WA` NOTICE FOR REQUIREMENT OF COMPLIANCE OF EMC RULES FOR PROTETI CON AND MAINTENANCE OF EXMING RIPARL)►N AREAS PROJECT # — OZ Q COUNTY � ,-a. v 4- r DWQ OFFICE O VERSION: NEUSE (15A NCAC 2B .0233) TAR-PAKLICO (15A NCAC 2B .0259) CATAWBA(15A NCAC 2B .0243) RANDLEIHAN (15A NCAC 2B .0250) OTHER j� .ram �. minn EXEMPT _ K IJ NOT EXF30' (DWQ INITIALS) (DWQ INITIALS) Property Owner's Mz= Phone Number (riome� Address Wl-._ City �. rj e—t Pro'ect Location (Nearest �uLk4 r C r. r- l�rf r91 r rye t,. 1 to Road, N (Business) State W$ter Body, etc) As indicated on attached map initialed by staff on DZ Description of Pronosed Proiect . rA Descriudon of Site r- r, m,r 7r r VIewcrd Violation rioted on site YES IO if yes, a Notice at Violation will be forwarded from the appropriate regional ot'fice. . Tjphs-acoKsed project which is to be located and constructed as described above Is hereby determined as ('EXEMPIINOT EXEMPT from compliance I the requirements of the aforementioned rules as It applies to section . This determination does not alleviate the necessity of your obtaining any other Property Owner's/Agent's DWQ Official's Signature Federal, or Local authorteatlon. Date of Determination 'This project may require a section 4041401 p rmit Ora CAMA Permit for the pimp I e, I sedvitr. Inquirles a6auid ba directed to tha DWQ C 02i Office at (919) 733-1736. Washington Office A (M) 946-WI. Raleigh OIIIee at (919) Sn47M WWaiagft afte at (910) 393,iM Wimma $a,— Ot11ce at 036) 7714630. Asheville Office at (SM) 251-6209, Fayetteville Offiee at (910) 4W4541, or Moortarille QIDee at (704) 663-1699. REVISED ENGINEERING REPORT FOR STORMWATER IMPROVEMENTS AT Tucker Creek Townes Craven County 2001-023 OWNER: Tucker Creek Townes, LLC 604 East Main Street Havelock, NC 28532 APR 1 1 2006 DWQ-WARD CONSULTING ENGINEER: THOMAS ENGINEERING, P.A. P.O. BOX 1309 NEW BERN, N.C. 28563-1309 ci 252-637-2727 ' e4� 252-636-2448 fax a email: jthomas744@aol.com Page 1 of 7 NARRATIVE PROJECT DESCRIPTION This project consists site development work to include installation of utilities, streets, parking, site grading, soil stabilization, and construction of townhouses on 5.93 acres (land disturbance of 3 acres) of land proposed for multi -family development for Tucker Creek Townes. SITE DESCRIPTION This site varies between elevation 0.00 ft and 28.00 ft NGVD and was previously cleared and grubbed under Erosion and Sedimentation Control Plan No. Crave-2003- 024. There are some 404 wetlands that borders Tucker Creek and Tucker Creek is subject to the Neuse River Buffer Rules. The run that borders the north side of the property between Tucker Creek Townes and Tucker Creek Section Three is not subject to the Neuse River Buffer Rules (exemption attached). ADJACENT PROPERTY This tract is bordered on the north by Tucker Creek, on the west by US 70 Highway, on the south by Sermons Blvd, and on the east by the Tucker Creek Estates Section Three subdivision. SOILS The Craven County Soil Survey indicates soil types on this tract are: Craven silt loams on the higher elevations, which are moderately well drained soils; Suffolk loamy sands on the side slopes which are well drained soils; and Masontown mucks which are located along the wetland fringes of Tucker Creek. STORMWATER MANAGEMENT Overall, this project has less than 30% impervious cover; however, if you exclude the wetlands, the project has 53% of impervious cover. Therefore, this development, having one drainage area, is being considered as a high density development with percent of impervious cover being 53%. Stormwater will be treated in a stormwater wet detention pond before being discharged into an existing wetlands that border the project. Page 2 of 7 SUPPORTING DOCUMENTS 1. Drainage Basin # 1 A. Site Data 1. Built Upon Area Streets (asphalt)& sidewalks (concrete) .................... 42,000 sf Buildings......................................................... 24,500 sf Total Built Upon Area ..................................... 66,500 sf (1.5266 ac) 2. Total Area (less wetlands) .................................. 125,888 sf (2.89 ac) 3. Percent Impervious Area (66,500 sf / 125,888 sf )(100) = 53 % > 30% (High Density) B. Determination of Wet Detention Pond Surface Area 1) Reference Attachment "A" 90% TSS removal 2) Proposed Pond Depth: 6.0 ft 3) Imperious Percent: 53 % 4) Drainage Area: 125,888 sf 5) Surface Area/Drainage Area: 2.91% (Interpolated from attachment "A") 90% TSS Removal Where: Impervious % = 53 % Permanent Pool = 6.0 ft 6) Pond Surface Area: a) Required 125,888 sf x 0.0291 = 3664 sf b) Provided Design pond surface area (SA)= 3776 sf (@ permanent pool elevation) C. Determination of required storage following a one inch rainfall event: Page 3 of 7 Where C for building roofs = 1.0 paved areas = 0.9 green areas = 0.2 1) Building Roofs: (24,500 sf)(1.0)(1 inch)(1 ft / 12 inch) = 2042 cf 2) Paved Areas: (42,000 sf)(0.9)(1 inch)(1 ft / 12 inch) = 3150 cf 3) Green Areas: (59,388 sf)(0.2)(1 inch)(i ft/ 12 inch) = 990 cf 4) Required Total Storage Volume = 6182 cf 5) Storage Depth (1 inch rainfall)(h) H = Volume/SA H = 6182 cf I [(3776 sf + 5192 so 12] H = 1.4 ft ( 1.5 ft provided) 6) Provided Storage Volume = 6727 cf D. Draw down determination (based on 1 inch rainfall) 1) Q (2 dys) = 4484 cf / (2 dys)(24 hrs/dy)(60 min/hr)(60/sec/min) = 0.026 cfs 2) Q (5 dys) = 4484 cf I (5 dys)(24hrs/dy)(60min/hr)(60/sec/min) = 0.0104 cfs 3) Orifice Size a) Orifice Formula Area = [Q/(Cd times the square root, of (2gh))] x 144 sqin/sf Where h = H/2 = .75 ft Cd = 0.6 g = 32.174ft/sec b) Area for Q (2dys) Area = [0.026 cfs / 0.6 times by the square root of (2g .75 ft))](144 sqin/sf) Area = 0.90 sq in Pipe Diameter = 2 times the square root of 0.90 / Pi = 1.07 in c) Area for Q (5dys) Area = [0.0104 cfs / 0.6 times the square root of (2g .75 ft))](l 44 sgin/sf) Area = 0.36 sq in Pipe Diameter = 2 times the square root of 0.361 Pi = 0.23 in Page 4 of 7 d) Selected Orifice Size Use 314 in orifice E. Runoff calculation for riser sizing and overflow: 1) Rational Method Q=CIA Where Q = Peak rate of runoff (cfs) C = Runoff coefficient Building Roofs = 1.0 Paved Areas = 0.9 Green Areas = 0.2 I = Average intensity of rainfall (inches) (I Oyr) A = Drainage area (acres) 2) Determination of Peak Flow Q C = (24,500 so(1.0)+(42,000 sf)(0.9)+(59,388 sf)(0.2) 70,874 sf C= 0.59 H (Height difference) = 4 ft L (length of travel) = 600ft Tc (time of Concentration = 5.0 min For i=7.1 in 10 Q=CIA Q = (0.59)(7.1 in)(2.89 ac) =12.11 cfs 10 For i=8.1 in 25 Q = (0.59)(8.1 in)(2.89 ac) = 13.81 cfs 25 For i = 10.2 in 100 Q = (0.59)(10.2(2.89 ac) = 17.39 cfs 100 F. Outlet pipe & riser determination Page 5 of 7 1. Riser Pipe 1.5 Q = 3.33(L-0.2H) H (Weir overflow formula for riser determination) Q = 12.11 cfs 1.0 H=6in L=10ft Riser diameter "d" = L 1 pi = 3.18ft (Use 48 in diameter riser) 2. Outlet Pipe = 36 in (see exhibit ") G. Calculate Emergency Overflow 1. Calculate overflow width 1.5 Q = 3.33(L-0.2H) H Where Q = Flow (cfs) L = length of weir (ft) H = Weir Head (ft) Solve for L where Q = 17.39 cfs 100 H=6in L = 15 ft @ 6 in head (Use 15 ft opening) Page 6 of 7 Exhibits Page 7of7 Worksheet Riser Outlet Pipe Worksheet for Circular Channel Project Description Project File c:lprogram fileslhaestadlfmw12001-023.fm2 Worksheet Riser Outlet Pipe Flow Element Circular Channel Method Manning's Formula Solve For Channel Depth Input Data Mannings Coefficient 0.024 Channel Slope 0.005000 ft/ft Diameter 30.00 in Discharge 13,81 cfs Results Depth 21.8 in Flow Area 3.83 ft2. Wetted Perimeter 5.11 ft Top Width 2.23 ft Critical Depth 1.25 ft Percent Full 72.74 Critical Slope 0.015425 ft/ft Velocity 3.61 ft/s Velocity Head 0.20 ft Specific Energy 2.02 ft Froude Number 0.49 Maximum Discharge 16.90 cfs Full Flow Capacity 15.71 cfs Full Flow Slope 0.003864 ftlft Flow is subcritical. 04/10/06 FlowMaster v5.11 03:47:49 PM Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 Page 1 of 1 Cross Section Riser Outlet Pipe Cross Section for Circular Channel Project Description Project File cAprogram fileslhaestadlfmw12001-023.fm2 Worksheet Riser Outlet Pipe Flow Element Circular Channel Method Manning's Formula Salve For Channel Depth Section Data Mannings Coefficient 0.024 Channel Slope 0.005000 ft/ft Depth 21.8 in Diameter 30.00 in Discharge 1181 cfs 0AI 1 M 30.00 in 1 V N H 1 NTS 04/10/06 FlowMaster v5.11 03:47:57 PM Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 Page 1 of 1