Loading...
HomeMy WebLinkAboutSW7050223_APPROVED PLANS_20050504STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW142�3 DOC TYPE El CURRENT PERMIT APPROVED PLANS ❑ HISTORICAL FILE DOC DATE e�22 07' YYYYMMDD 70 027-3 - KALE ROAD EXISnNG RCP CHECK DAM G12 CAI � y J W U� J � CIS LLJ 0 r .� O LOT 4 U � a O z m EXISTING SWALE C-1 O Q TO BE REGRADED s.� - Lij c Q Q uj m = J o_ CL CHECK DAM G12 LOT 3 �(0 � ed) z o �doo 0 0 0 �Q SIL T FEJ 112 4 LOT 2 N w N/F { IP E',/ S. & SAI\IF�PA L. PARKER 111'F l_) BOOK 1681, PAGE 232 LOT 1 I-- ........... �— gNEW SWALE C-1 ® 0.30Z1 M TH 3 : 1 SIDE SLOPES I - cD EMERGENCY IN V. = J 19.60' OVERFLOW ELEV = 23.00' MOTH = 20, 00' RIP RAP LINED SLOPE SILT FENCI 1/2 v 00 0 o t� I N /F .SEFFREY G. DAIL PFF I , ROOK 1796. PAGE 396 1 N /F 1 JEFFRE Y G. D AI L DEED BOOK 1804, PAGE 953 4.5� I PERPETUAL AVIATION EASEMENT DEED BOOK 575, PAGE 40 TO CITY OF NEW BERN. _ I 25.5� 09 �b 1 �1 24\ 25.0 N /F ST. PETERS PENTECOSTA\ DEED 001< 2127, PAGE 768 SITE DATA TOTAL ACRES : 6.58 ACRES 0 \ OWNER/DEVELOPER: ROBERT EUGENE DUNN, SR. / 507 JIMMIES CREEK ROAD NEW BERN, NORTH CAROLINA 28560 252.633.2056 / r CONSULTING ENGINEER: THOMAS ENGINEERING, P.A. 7 0 (JOHN G. THOMAS, P.E. LIC# 10147) 403-C AIRPORT ROAD P.O. BOX 1309 NEW BERN, NORTH CAROLINA 28563 252.637.2727 - FAX: 252,636.2448 EMAIL: JTHOMAS744@AOL.COM \ LAND SURVEYOR: BRAD SUITT & ASSOCIATES (BRAD L. SUITT, PLS, REGISTRATION #L--3767) 505 JIMMIES CREEK ROAD P.O. BOX 12142 1J /F NEW BERN, NORTH CAROLINA 28561 252.635.3333 F )PFRT GRYB DEED E'' ► 18, 00 , PAGE 32 North Can** APPROVED NORTH CAROUNA ENVIRONMENTAL DMA MANAGEMENT COMMISSION MAY D4vlsIoN of a Far �.�_ Buffer QUALITY Date . �Q 20� ' .C..S Reviewed swmwvbw Pon \ 1��ttttttttfrrr -1 `'�ittttttrtrfr �'�C, INF, f�.,� �� 'S C A 0l''r� F. _ SEAL 9 _ S C-438 Zq E 14 Jul ,rr,++,lll ll lit'1ti ,11 t 'rlflll,ll1115"'`11,_ ��1 CRAPFi1C SCALE r* 1 9 8 3 *'����. �f �►�, ��0,�` lrrrtlitttt�t rrf ]titt��� 50 1-. 15 12.5 0 R I M 4" DIA. X 1/2" H.D. GALV. WASHER- 2 4 CONT. ELEV. 25.00' COUNTER BORE 1-3/4" ROD, WASHER PUBLIC ROAD REARR AND NUT COATED W/COAL TAR EPDXY . . • . 10 41 INCH STORM ELEVATION 22.00' . . . . . . . . . . . 1 Bt}L 0 i4k, PERMANENT POOL ELEVATION 20.50' . 6"x6"x1/2" H.D. GALV. T EXISTING GRADE EXISTING GRADE STEEL WASHER O3W 2"-3" COARSE AGGREGATE4' LONG BLOCK 1 POND3,000 P.S.I. CONC. I 3 BASE TO IAINIMUM 6" IN DEPTH EL 14.50' VARIESI 4"X6" WALER 4' O.C. (TYP) -0" SOIL FABRIC TURNED OUT 18" 2"WX10" T&G 8"X8"X12'-0" POST 2' A5 RQ'D 14' MIN MAX SLOPE = 0,30% CONSTRUCTION EXIT DETAIL AH CROSS—SECTION TYPICAL SWALE C —1 N.T.S. 2 AT WET DETENTION BASIN CROSS SECTION?E%, At. TS, kS�V VARIES AS BY ENa1NEER 1 MINIMUM ENV'1 OAU� AT 11' IN7ERVAL3 IN. TOP STRAND 10 GAME UNE MARES 12-1/2 GAUGE VEGETATIVE SHELF MAWMIN. 1 G cA TRASH RACK W1T11 ANTI -VORTEX PLATE & TRASH GUARD STRAP TOP OF RISER - EL. 25.00' FlLL SLUPE TOP OF SLOPE EL. 27.00' 8' PVC SCH. 40 BULKHEAD N GROUND UWE VEGETATIVE SHELFPERMANENT P -30' BCCMP 6OLF W/FES TOP OF BERM 19.50' 6' PVC TEE EL 20.50'1 EL 18.5 CONCRETE FlLL TEMPORARY SILT FENCE DETAIL EL. 14.50' WWkHTSEAL P60"IP BCCMP p ORIFICE2„CAP PIPE 1"� c" N.T.S. 2 OREBAY o POND 'j"'L HOLE 4 EL 16.00' ru MARE 12FILTER FABRIC EL. 14.50' FILTER FABRIC POND 3 A .4 a CONC. SLAB RIP RAP LINED SO EL 14.50' 1 \ \ 8'-0• GENERAL NOTES: UA L 1. ARE SHALL BE A MINIMUM OF 32" IN WIDTH AND SHALL HAVE A L F CROSS SECTION D AI L MINIMUM OF 6 LINE WIRES %1TH 17.` STAY SPA^iNG N. , N. 2. FILTER FABRIC SHALL BE A MINIMUM OF 35" IN WIDTH AND SHALL BE FASTENED ADEQUATELY TO THE WIRE AS DIRECTED BY THE EN- GINEER. 3. STEEL POSTS SHALL BE 5 FEET IN HEIGHT AND SHALL BE OF THE SELF -FASTENER ANGLE STEEL TYPE. 4. WOOD POSTS SHALL BE A MINIMUM OF 8 FEET IN HEIGHT AND 3 INCHES OR MORE IN DIAMETER. WIRE FABRIC SHALL BE FASTENED TO WOOD POSTS WITH NOT LESS THAN 09 WIRE STAPLES 1-1/2" LONG. TOP OF VEGETATIVE BANK SHELF 52.0 ' 6' 5.0 ' 10' MINIMUM-- CARRY RIP -RAP UP #1 RIP -RAP (TYP) IDES OF SPILLWAY 1' MINIMUM ) 18" INTO BAN = #5 WASHED STONE x.............. 1 EL. 24.50' (TYP) VARfES 1 1 STORA E EL. 22.00' MAINTENANCE: 1. INSPECT CHECK DAMS AND CHANNELS FOR DAMAGE AFTER EACH RUNOFF EVENT. —�t PERMANENT POND EL. 20.50' 2. REMOVE SEDIMENT ACCUMULATED BEHIND DAMS AS NEEDED TO PREVENT DAMAGE TO CHANNEL VEGETATION, ALLOW THE CHANNEL TO DRAIN THROUGH THE STONE CHECK DAM AND PREVENT LARGE FLOWS FROM CARRYING SEDI- 3 1 iE 0' MENT OVER THE DAM. ADD STONES TO DAM AS NEEDED TO MAINTAIN DE- SIGN HEIGHT AND CROSS --SECTION. SECTION A -_A CROSS SECTION N.T.S. N.T.S. t'ttttltlirlr!! r tt tt1�r r •' GINF, rffr .�'�gt CAR0 ffe �� CARRY RIP -RAP UP SIDES OF SPILLWAYAosF10- � A �= SEAI, = a =4 NOTE: KEY THE STONE INTO THE DITCH = C-438 �, M 1 14 BANKS A MINIMUM OF 18" TO AVOID 2' MIN. WASHOUTS FROM OVERFLOW AROUND THE DAM AXIMUM SLOPE '.�`ri+r>>>=t•3 1 N. FREEBOARD ¢ �� rrfrlrr 9t813 "-,�` fitt�4o 1 / o FLOWS WASHED ' 00 o Soo a1 1 BLDG. BLDG. -*—TEMPORARY GRASS 75'-100' AHEAD STONE gQg�o� � OF CHECK DAM ...' hoc or_!oo 0 a 1 RfP-RAP A FINAL DRAWINGSo,P 1 1/2" Released for permits only, SF9P VEME Ii�ALT MIN VARIES Not released for construction MAX/ _ GRAVEL & RIP --RAP CHECK DAM,.- G MW MN ram► #1 of , WM CAMJNA 6" CABC N.T.S. 2 Thomas Engineering, P.A. CROSS SECTION?D%, 403—C Airport Road N.TS, PO Box 1309 New Bern, North Carolina 28563 Tel. 252.637.2727 Fax. 252.636.2448 1 DINO COMMENTS JGT 4.27.05 SCALE AS NOTED PROJECT #: 2003029\IMPRO... DATE : 10/20/03 TLOrT�D4/� NO. DESCRIPTION BY DATE IPLOT FACTOR: 1 : 1(E) PLOT NAME: 02-DETAILS SHEET: 02 OF 02