HomeMy WebLinkAboutWQ0022562_Sewer Extension_20030505pF WATF9 State of North Carolina 0� 4�G Department of Environment and Natural Resources r Division of Water Quality FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS (Pressure sewers systems are not to be included as part of this application package) INSTRUCTIONS: Indicate that you have included the following list of required application package items by checking the space provided next to each item. Failure to submit all required items will lead to your application being returned as incomplete or additional processing and review time. This form may be photocopied for use as an original. ® I. Application Form - Submit one original and one copy of the completed and appropriately executed application form. Any changes to this form will result in the application being returned. The Division of Water Quality (Division) will only accept application packages that have been fully completed with all applicable items addressed. You do not need to submit detailed plans and specifications unless you respond NO to Item 1302). ® II. Application Fee - Submit a check in the amount of $400 made payable to: North Carolina Department of Environment and Natural Resources (NCDENR). ❑ III. Certificates of Public Convenience and Necessity — If the application is being submitted in the name of a privately -owned public utility, submit two copies of the Certificate of Public Convenience and Necessity (CPCN) which demonstrates that the public utility is authorized to hold the utility franchise for the area to be served by the sewer extension. If a CPCN has not been issued, provide two copies of a letter from the North Carolina Utilities Commission's Public Staff that states that an application for a franchise has been received, that the service area is contiguous to an existing franchised area, and/or that franchise approval is expected. The project name in the CPCN or letter must match that provided in Item A(2a) of this application. ❑ IV. Operational Agreements — Submit one original and two copies of a properly executed operational agreement if the sewer extension will be serving residential or commercial lots (e.g., houses, condominiums, townhomes, outparceis, etc.) that will be owned by a homeowners' association or developer (Item B(2b)). If the applicant is a homeowners' association, use Form HOA 02/03. If the applicant is a developer, use Form DEV 02/03. EVEN IF THE PROJECT WILL BE TURNED OVER TO A MUNICIPALITY, FORM DEV 02/03 IS REQUIRED. ❑ V. Flow Acceptance Letters — If the owner of the downstream sewers and/or WWTF is different from the applicant, submit two copies of a flow acceptance letter from the owner of the downstream sewers and WWTF, if different. Flow acceptance letters must contain the following minimum information: applicant and project name, amount of flow accepted, and name and permit number of the receiving sewers/WWTF. The flow acceptance must not expire prior to permit issuance and must be dated less than a year prior to the application date. Intergovernmental agreements or other contracts will not be accepted in lieu of a project -specific flow acceptance letter. ® VI. Map — Submit an 8.5-inch by 11-inch copy of the portion of a 7.5-minute USGS Topographic Map along with this form. The map should identify the entire project area location as well as the closest downslope surface waters as clearly as possible. Each map portion must be labeled with the map name and number, the identified location, and be of clear and reproducible quality. For instance, if the project involves 4 miles of interceptor sewer that traverses over or near several different waterbodies (or counties, basins, etc.), the map should have location ID's for each different waterbody (where the sewer line is within 100 feet of such waterbody - see Instruction VII). ® VII. Watershed Classifications — Section C • If any portion of the project is within 100 feet of any down slope surface water, Section C must be completed for the pertinent sections. If the entire project area is a minimum of 100 feet away from any down slope surface waters BUT there is a pump station involved where a history of power outage is to be used to provide adequate design storage instead of dual feed or permanent or portable generator, Section C must be completed to demonstrate that the closest down slope surface water is Class C (see 15A NCAC 2H .0219(h)(3)(D)). Use the guidance document entitled, "Determining Watershed Classifications for Form FTA 02/03 (Fast -Track Sewer Systems)" available from http://h2o.enr.state.nc.us/ndpu or by contacting the appropriate regional office. INSTRUCTIONS FOR FORM FTA 02/03 ❑ Vill. Environmental Assessments — If this project is subject to an Environmental Assessment (EA) ]15A NCAC 01C .0500], this application can not be used. Send the project application on Form PSFMGSA 10/99 to the Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. Applications can not be processed until a Finding of No Significant Impact (FONSI) or Environmental Impact Statement (EIS) has been issued. A copy is to be submitted with that permit application. ® IX. Certifications — Section D The application must be certified by both the applicant and a North Carolina Registered Professional Engineer (PE). The applicant signature must match the signing official listed in Item A(1 b). The PE should NOT certify the application if he/she is unfamiliar with 15A NCAC 2H .0200, the Gravity Sewer Minimum Design Criteria (most recent version) and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (most recent version), as applicable to the project. Certification by a PE who is unfamiliar with these documents is subject to NC Board referral. THE COMPLETED FTA 02/03 APPLICATION PACKAGE, INCLUDING ALL SUPPORTING DOCUMENTS AND $400 FEE, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE REGIONAL OFFICE ADDRESS COUNTIES SERVED Asheville Regional Office 59 Woodfin Place Avery, Buncombe, Burke, Caldwell, Asheville, North Carolina 28801 Cherokee, Clay, Graham, Haywood, Henderson, Jackson, Macon, Madison, (828) 251-6208 McDowell, Mitchell, Polk, Rutherford, Swain, (828) 251-6152 Fax Transylvania, Yancey Fayetteville Regional Office Anson, Bladen, Cumberland, Hamett, Hoke, 225 Green Street Suite 714 Montgomery, Moore, Robeson, Richmond, Fayetteville, North Carolina 28301 Sampson, Scotland (910) 486-1541 (910) 486-0707 Fax Mooresville Regional Office 919 N Main Street Alexander, Cabarrus, Catawba, Cleveland, Mooresville, North Carolina 28115 Gaston, Iredell, Lincoln, Mecklenburg, Rowan, (704) 663-1699 Stanly, Union (704) 663-6040 Fax Raleigh Regional Office Chatham, Durham, Edgecombe, Franklin, 1628 Mail Service Center Granville, Halifax, Johnston, Lee, Nash, Raleigh, North Carolina 27699-1628 Northampton, Orange, Person, Vance, Wake, (919) 571-4700 Warren, Wilson (919) 571-4718 Fax Washington Regional Office Beaufort, Bertie, Camden, Chowan, Craven, 943 Washington Square Mall Currituck, Dare, Gates, Greene, Hertford, Washington, North Carolina 27889 Hyde, Jones, Lenoir, Martin, Pamlico, (252) 946-6481 Pasquotank, Perquimans, Pitt, Tyrrell, (252) 975-3716 Fax Washington, Wayne Wilmington Regional Office Brunswick, Carteret, Columbus, Duplin, New 127 Cardinal Drive Extension Hanover, Onslow, Pender Wilmington, North Carolina 28405 (910) 395-3900 (901) 350-2004 Fax Winston-Salem Regional 585 Waughtown Street Alamance, Alleghany, Ashe, Caswell, Office Winston-Salem, North Carolina Davidson, David, Forsyth, Guilford, 27107 Rockingham, Randolph, Stokes, Suny, (336) 771-4600 Watauga, Wilkes, Yadkin (336) 771-4631 Fax For more information, visit our web site at: http://h2o. enr. state. nc. us/ndpu/ INSTRUCTIONS FOR FORM FTA 02/03 05/05/2003 10:56 9104379923 ALLEN, ALLEN,& ASSOC PAGE 03 FAST -TRACK APPLICATION for GRAVITY SEWERS, PUW STATIONS, AND FORCE MAINS PAGE 1 USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Appcompleted by DWC) _; lication Number: (to Owner. Full Legal Name (company,municipality, HOA, utility, etc.) . ........ ..."ilb Will!am er i.' i Todd Powell Cftv Manag SigningOfficial ocial Name and Title (Please review 15A NCAC 2H.0206(b) for authorized signitg official L,' 1 c. The legal entity who will own this system is: IndMdualState/County [Jqc!rp Partnership P.O, Box 1388 le. Lumberton Street Address City .11 f- North Carolina I g. 28358 State Zip Code '(910) 671-3806 1i. (910)671-3814 Telephone Facsimile E-mail .... ...... . Project (Facility)) Informaftn: - ----- �2a James Musslewhite �b. Robeson ty Brief Pruiect-NaCounWhere Project is Located —me (permit will refer to this name) a �13. Contact Person: 3a William Todd Powell, City Manager Name and Affiliation of Someone Who Can Answer Questions About this Application .3b. (910) 671 - 3806 Phone Number E-mail • 1. Project lsXNew [] Modification (of an existing permit) If Modification, Permit No., Owner is 9 Public (sWp to Item B(3)) ❑ Private (go to Item 2(a)) if private,applicant will be: 2b. If sold facilities owned by a (must choose one) . C;J Retaining ownership (i.e. store, church, single office, etc.) ❑ Public Utility (Instruction 111) ❑ Leasing units (lots, townhomes, etc. - skp to Item B(3)) C] Homeowner Assoc./Developer (Instruction IV) J Selling units (lots, townhomes, etc. - go to Item B(2b)) ' `::'a. City of Lumberton Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project City of Lumberton, WWTF 4b. NCO024571 Name of WWTF WWTF Permit No. Be. City of Lumberton �b, 12 Owner of Downstream Sewer Receiving Sewer Size 6. The origin of this wastewater is (check all that apply): unknown Permit Number of Downstream Sewer Residential Subdivision ❑ Car Wash Apartments/Condominiums ❑ InsftAon wo % Domestic/Commercial Mobile Home Park ❑ Hospital ❑ % Industrial School ❑ Church J X Restaurant ❑ Nursing Home %Other (specify); ❑ Office X Other (specify). Retail — ---------- 7. Volume of wastewater to be pe rmitted in this project, 12400 gallons per day If the permitted flow is zero, indicate why, ❑ Interceptor Line - Flow will be permitted is subsequent permits that connect to this line ❑ Flow has already been allocated in Permit No. ❑ Rehabilitation or replacement of existing sewer with no new flaw expected 05/05/2003 10:56 9104379923 ALLEN, ALLEN,& ASSOC PAGE 02 FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 2 9 Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .021 9(l) for Item 8(7) or the design flow for line or pump station sizing 0 zero flow in the space below. Values other than that in 15A NCAC 2H.0219(IX12) must be approved prior to submittal of this application. Submit aseparate request to -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in the Division of Water Quality, Non accordance with 15A NCAC 2H.0219(IX3). af of Retail Space 120 gpd11000 sf 12400 gpdl i 2 Restaurants (100 seats each @ 50 gpd/seat 10,000 gpd + 20,000 -essary) 10. Summary of Sewer Lines to be Permitted (attach additional sheets If nec Gravity Length (feet) or Form Main Size (inches) Leng(pull down menu) 560 Gravity 8 • Gravity Gravity . ... ....... ........ Gravity Gravity Gravity Gravity 0.11 ENTER TOTAL LINE LENGTH IN MILE-, ssary) 1, sunp,rdry of Pump Stations to be Permitifed (attach additional sh soft as nece Power RelliablIfty Option Location ID Design Flow Operational Point (dual line food. permanent generator, (as shown on plans)._:......._C31PM.Q T�D�l _pprt ble genwator, wet wall storage ..... ... . ..... d F 12 Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting o Pump Stations an once .- 't ' I Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 5A NCAC 2H .0200 as applicable? [@Yes []No it no, please reference the pertinent minimum design criteria or regulation and indicate why a variance Is mquested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT To THE VARIANCE WITH YOUR APPLICATION :113 Have the following permlts/certific;Mons been submitted for approval? wetlend/Stream Crossings - General Permit or 401 Certification? [3 Yes El No X N/A Sedimentation and Erosion Control Plan? X Yes ❑ No ❑ N/A Stormwater7 ❑ Yes [I No X N/A FAST-TRAC-K APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3 CO) Z _O E— U_ LL k- U W- Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02103 i (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as! necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: X A Watershed Classification is not needed because all pants of the project are at least 100 feet away from any down slope waterbody; AND, X A Watershed Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID Name of Waterbody Stream Waterbody on Map Waterbody County River Basin Index Classification i Submit the 8.5" x 11" topographic map as required in Instruction VI regardless of whether a classification is provided! 1. Applicant's Certification: 1 attest that this application for James Musslewhite has been reviewed by me and is accurate and complete to the best of my knowledge. l understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being retumed as incomplete. Note. In accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor whi7h7 include a fine not to exceed $10, 000 as well as civil penalties up to $25, 000 per violation. / 7 1a. William Todd Powell 4/14/03 Signing Official Signature — 0 1/ Date 2. Professional Engineer's Certification: I attest that this application for James Musslewhite has been reviewed by me and is j accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. l further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that / have reviewed this material and have judged it to be consistent with the proposed design.; Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10, 000 as well as civil penalties up to $25, 000 per violation. 2a. Harvey H. Allen Professional Engineer Name 2b. Allen -Allen & Associates, PA Engineering Firm 2c. 114 Hale Street Address .2d. Fayetteville 2e. NC 2f. 28301 City State Zip 2g. (910) 437-9800 2h. (910) 437-9923 2i. hallenl@nc.rr.com i i o. i 01 i i i Telephone Facsimile E-mail Seal, Signature & Date Copyrighl:OM Maps a la carte. Inc. Y j 1.✓ 4 'r.. • t '..� ,� + '!' 4 � � . "�., its e.,,.. �:f s �j "7 . yar { i b t c 4h L �- _ w _ s sr F ' •�- i � —� +» " •- � jjf -'+,tr °�, ''Y. ._ •. E i j //r - � r ,? i{ P'7t•.' `� �"�1 - ' ��, � --� `� s .,i,�. � -- � S � yam. 1 µ • ``rr.-.. ' �4 i"}j`-i.""Ei""�-( `sic`-- - - f+ —..^- z_`�aV`sf.{ j YY • j�. re• —M— t j �'. N. �. .3 { , -ire 5` dt Radio TgDwei 0 1000 1500 2000 meters I i _ I I miles I Qi5 1 U The TopoZone is produced by Maps a la carte, Inc. - © 2000 Maps a la carte, Inc. - All rights reserved. Use of this site is governec Terms of Use. We care about your privacy - please consult our Privacy Statement for details. 25 ALLEN-ALLEN & ASSOCIATES, PA Civil • Municipal • Construction Management Land Planning • Land Surveying Mr. Grady Dobson NCDENR - DWQ 225 Careen Street Suite 714, Systel Bldg Fayetteville, NC 28301 Date: April 29, 2003 RE: James Musslewhite - Fast Track Application 114 Hale Street Fayetteville, NC 28301 (910) 437-9800 (910) 437-9923 Fax E-mail: hallent@nc.rr.com www.allenalleneng.com Dear Grady: Please find the following enclosed for your use: r Li-JP"R0 20o3 — One (1) check for $400.00; one (1) copy of the subject QUAD map; L) 'y and three (3) copies of the subject application. Cordially: A Harvey Allen enclosures JOHNNY NOBLES & ASSOCIATES SURVEYORS P. O. BOX 407 PH. 910-738-6875 LUMBERTON, NC 28359 PAY TO THE ORDER OF u)q o8459 66-368/531 DATE � $ Q(,P0 _ DOLLARS GtUR MY FOR - -- - - -- - -. - ll'