Loading...
HomeMy WebLinkAbout20200881 Ver 1_401 Application_20200706DWR mrlslon of Water Resources Pre -Construction Notification (PCN) Form April 11, 2020 Ver 3.1 Initial Review Has this project met the requirements for acceptance in to the review process?* r Yes r No Is this project a public transportation project?* C Yes r No Change only if needed. BIMS # Assigned 20200881 Is a payment required for this project?* r No payment required r Fee received r Fee needed - send electronic notification Select Project Reviewer* Stephanie Goss:eads\szgoss Information for Initial Review 1a. Name of project: Bellvue Mill Greenway Bridge 1a. Who is the Primary Contact?* Donald Sever 1b. Primary Contact Email:* don.sever@summitde.net Date Submitted 7/6/2020 Nearest Body of Water LIT1 TO ENO RIVER Basin Neuse Water Classification WS-V;NSW Site Coordinates Latitude: 36.073205 A. Processing Information County (or Counties) where the project is located: Orange Is this a NCDMS Project r Yes r No Longitude: -79.114643 Is this project a public transportation project?* r Yes r No 1a. Type(s) of approval sought from the Corps: W Section 404 Permit (wetlands, streams and waters, Clean Water Act) r Section 10 Permit (navigable waters, tidal waters, Rivers and Harbors Act) Version#* 1 Reviewing Office* Raleigh Regional Office - (919) 791-4200 1c. Primary Contact Phone:* (919)810-7950 U 1b. What type(s) of permit(s) do you wish to seek authorization? W Nationwide Permit (NWP) r Regional General Permit (RGP) r Standard (IP) 1c. Has the NWP or GP number been verified by the Corps? t^ Yes r No Nationwide Permit (NWP) Number: NWP Numbers (for multiple NWPS): 1d. Type(s) of approval sought from the DWR: W 401 Water Quality Certification - Regular r Non-404 Jurisdictional General Permit r Individual Permit 14 - Linear transportation le. Is this notification solely for the record because written approval is not required? For the record only for DWR 401 Certification: For the record only for Corps Permit: F- 401 Water Quality Certification - E)press P Riparian Buffer Authorization 1f. Is this an after -the -fact permit application?* r Yes r No 1g. Is payment into a mitigation bank or in -lieu fee program proposed for mitigation of impacts? r Yes r No 1g. Is payment into a mitigation bank or in -lieu fee program proposed for mitigation of impacts? r Yes r No Acceptance Letter Attachment 1h. Is the project located in any of NC's twenty coastal counties? r Yes r No 1j. Is the project located in a designated trout watershed? r Yes r No B. Applicant Information 1d. Who is applying for the permit? r Owner W Applicant (other than owner) le. Is there an Agent/Consultant for this project?* r Yes r No 2. Owner Information 2a. Name(s) on recorded deed: BELLEVUE MILL LLC 2b. Deed book and page no.: 6177/532 2c. Responsible party: Mark Bouldin 2d.Address Street Address 17250 LANCASTER HIGHWAY, SUITE 608 Address Line 2 city Charlotte Fbstal / Zip Code 28277 2e. Telephone Number: (727)592-8889 2g. Email Address:* mbouldin@kronoscapital.com State / Rwince / Ifgion NC Country USA 2f. Fax Number: r- Yes r No r Yes r No 3. Applicant Information (if different from owner) 3a. Name: Donald Sever 3b. Business Name: Summit Design and Engineering Servicess PLLC 3c.Address Street Address 320 EXECUTNE COURT Address Line 2 (Sty State / Province / F bgion Hillsborough NC Postal / Zip Code Country 27278 USA 3d. Telephone Number: 3e. Fax Number: (919)732-3883 3f. Email Address:* don.sever@summitde.net 4. Agent/Consultant (if applicable) 4a. Name: Don Sever 4b. Business Name: Summit Design and Engineering Services 4c.Address Street Address 320 Executive Court Address tine 2 (Sty State / Province / Region Hillsborough NC Postal / Zip Code Country 27278 USA 4d. Telephone Number: 4e. Fax Number: (919)732-3883 4f. Email Address:* don.sever@summitde.net Agent Authorization Letter* Property Owner Certification MCB signed 30JUN20.pdf 267.54KB C. Project Information and Prior Project History U 1. Project Information 1b. Subdivision name: (d appropriate) 1c. Nearest municipality / town: lllsborough 2. Project Identification 2a. Property Identification Number: 2b. Property size: 9864653481 9.25 2c. Project Address Street Address Address Line 2 city State / Province / Region Postal / Zip Code Country 3. Surface Waters 3a. Name of the nearest body of water to proposed project:* UT1 TO ENO RIVER 3b. Water Resources Classification of nearest receiving water:* WS-V;NSW 3c. What river basin(s) is your project located in?* Neuse 3d. Please provide the 12-digit HUC in which the project is located. 030202010302 4. Project Description and History 4a. Describe the existing conditions on the site and the general land use in the vicinity of the project at the time of this application:* THE SITE IS CURRENTLY WOODED WITH A CREEK RUNNING NORTH TO SOUTH. AN EXISTING SANITARY SEWER EASEMENT RUNNING WEST TO EAST. THE PROPOSED USE IS A GREENWAY TRAIL WITH A BRIDGE CROSSING THE CREEK. 4b. Have Corps permits or DWR certifications been obtained for this project (including all prior phases) in the past?* r Yes r No r Unknown 4d. Attach an 8 1/2 X 11 excerpt from the most recent version of the USGS topographic map indicating the location of the project site. (for DWR) 4e. Attach an 8 1/2 X 11 excerpt from the most recent version of the published County NRCS Soil Survey map depicting the project site. (for DWR) 4f. List the total estimated acreage of all existing wetlands on the property: 0 4g. List the total estimated linear feet of all existing streams on the property: 683 4h. Explain the purpose of the proposed project:* THE PURPOSE OF THE PROPOSED PROJECT IS TO HAVE A PEDESTRIAN GREENWAY TRAIL CONNECT BELLVUE AVE. AND KNIGHT ST.. 4i. Describe the overall project in detail, including indirect impacts and the type of equipment to be used:* A 6 FOOT WIDE, MULCHED GREENWAY TRAIL WILL BE CONSTRUCTED ON BOTH SIDES OF THE CREEK. THE CREEK CROSSING WILL INCLUDE A 25 FOOT SPAN BRIDGE WITH A 10 FOOT LONG CONCRETE APPROACH AT EACH END. 4j. Please upload project drawings for the proposed project. Bellvue Mill Greenway Bridge buffer impacts.pdf 600.06KB 5. Jurisdictional Determinations 5a. Have the wetlands or streams been delineated on the property or proposed impact areas?* r Yes r No r Unknown Comments: 5b. If the Corps made a jurisdictional determination, what type of determination was made?* r Preliminary r Approved r Not Verified r Unknown r N/A Corps AID Number: 5c. If 5a is yes, who delineated the jurisdictional areas? Name (if known): Agency/Consultant Company: Other: 5d1. Jurisdictional determination upload 6. Future Project Plans 6a. Is this a phased project?* r Yes r No Are any other NWP(s), regional general permit(s), or individual permits(s) used, or intended to be used, to authorize any part of the proposed project or related activity? D. Proposed Impacts Inventory 1. Impacts Summary la. Where are the impacts associated with your project? (check all that apply): r Wetlands r Streams -tributaries P Buffers r Open Waters r Pond Construction 6. Buffer Impacts (for DWR) 6a. Project is in which protect basin(s)? Check all that apply. V Meuse r Tar -Pamlico r Catawba r Randleman r Goose Creek r Jordan Lake r Other 6b. Impact Type 6c. Per or Temp 6d. Stream name 6e. Buffer mitigation required? 6f. Zone 1 impact 6g. Zone 2 impact Greenway P Ui1 to Eno River No 650 444 Greenway T U`r1 to Eno River No 1,285 891 6h. Total buffer impacts: Zone 1 Zone 2 Total Temporary impacts: 1,285.00 891.00 Zone 1 Zone 2 Total Permanent impacts: 650.00 444.00 Zone 1 Zone 2 Total combined buffer impacts: 1,935.00 1,335.00 61. Comments: Supporting Documentation Bellvue Mill Greenway Bridge buffer impacts.pdf 600.06KB E. Impact Justification and Mitigation 1. Avoidance and Minimization 1a. Specifically describe measures taken to avoid or minimize the proposed impacts in designing the project: THE STREAM CROSSING IS PERPENDICULAR TO THE STREAM AND IS ONLY CROSSED ONCE. A PORTION OF THE MULCHED TRAIL WILL TURN TO AVOID TREES CLOSE TO THE STREAM. 1b. Specifically describe measures taken to avoid or minimize the proposed impacts through construction techniques: The trail design is kept as close to grade as possible to limit the extents of cut/fill. 2. Compensatory Mitigation for Impacts to Waters of the U.S. or Waters of the State 2a. Does the project require Compensatory Mitigation for impacts to Waters of the U.S. or Waters of the State? r Yes r No 2b. If this project DOES NOT require Compensatory Mitigation, explain why: F. Stormwater Management and Diffuse Flow Plan (required by DWR) 1. Diffuse Flow Plan 1a. Does the project include or is it adjacent to protected riparian buffers identified within one of the NC Riparian Buffer Protection Rules? r Yes r No What type of SCM are you providing? r Level Spreader r Vegetated Conveyance (lower SHWT) r Wetland Swale (higher SMNT) r Other SCM that removes minimum 30 % nitrogen W Proposed project will not create concentrated stormwater flow through the buffer Diffuse Flow Documentation U 2. Stormwater Management Plan 2a. Is this a NCDOT project subject to compliance with NCDOT's Individual NPDES permit NCS000250? * r Yes r No 2b. Does this project meet the requirements for low density projects as defined in 15A NCAC 02H .1003(2)? r Yes r No Comments: G. Supplementary Information 1. Environmental Documentation la. Does the project involve an expenditure of public (federal/state/local) funds or the use of public (federal/state) land?* r Yes r No 2. Violations (DWR Requirement) 2a. Is the site in violation of DWR Water Quality Certification Rules (15A NCAC 2H .0500), Isolated Wetland Rules (15A NCAC 2H .1300), or DWR Surface Water or Wetland Standards or Riparian Buffer Rules (15A NCAC 2B .0200)? * r Yes r No 3. Cumulative Impacts (DWR Requirement) 3a. Will this project result in additional development, which could impact nearby downstream water quality?* r Yes r No 3b. If you answered "no," provide a short narrative description. it is a greenway trail 4. Sewage Disposal (DWR Requirement) 4a. Is sewage disposal required by DWR for this project?* r Yes r Nor N/A 5. Endangered Species and Designated Critical Habitat (Corps Requirement) 5a. Will this project occur in or near an area with federally protected species or habitat?* r Yes r No 5b. Have you checked with the USFWS concerning Endangered Species Act impacts?* r Yes r No 5d. Is another Federal agency involved?* r Yes r No r Unknown 5e. Is this a DOT project located within Division's 1-8? r Yes r No 5f. Will you cut anytrees in order to conduct the work in waters of the U.S.? r Yes r No 5g. Does this project involve bridge maintenance or removal? r Yes r No 5h. Does this project involve the construction/installation of a wind turbine(s)?' r Yes r No 51. Does this project involve (1) blasting, and/or (2) other percussive activities that will be conducted by machines, such as jackhammers, mechanized pile drivers, etc.? r Yes r No 5j. What data sources did you use to determine whether your site would impact Endangered Species or Designated Critical Habitat? N/A Consultation Documentation Upload 6. Essential Fish Habitat (Corps Requirement) 6a. Will this project occur in or near an area designated as an Essential Fish Habitat?* r Yes r No 6b. What data sources did you use to determine whether your site would impact an Essential Fish Habitat?* N/A 7. Historic or Prehistoric Cultural Resources (Corps Requirement) 7a. Will this project occur in or near an area that the state, federal or tribal governments have designated as having historic or cultural preservation status?* r Yes r No 7b. What data sources did you use to determine whether your site would impact historic or archeological resources?* WA 7c. Historic or Prehistoric Information Upload 8. Flood Zone Designation (Corps Requirement) 8a. Will this project occur in a FEMA-designated 100-year floodplain?* r Yes r No 8c. What source(s) did you use to make the floodplain determination?* 3710986400K Miscellaneous Comments Miscellaneous attachments not previously requested. Signature * W By checking the box and signing below, I certify that: • I have given true, accurate, and complete information on this form; • I agree that submission of this PCN form is a "transaction" subject to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act'); • I agree to conduct this transaction by electronic means pursuant to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act'); • I understand that an electronic signature has the same legal effect and can be enforced in the same way as a written signature; AND • I intend to electronically sign and submit the PCN form. Full Name: Donald A. Sever Signature Date 7/6/2020 u PROPERTY OWNER CERTIFICATION / AGENT AUTHORIZATION Project Name/Description: Belivue Mill Greenway Bridge Date: 6/10/2020 The Department of the Army U.S. Army Corps of Engineers, Darlington Avenue Wilmington, NC 28403 Attn: Samantha Dailey Wilmington District 69 Field Office: Ralei I, the undersigned, a duly authorized owner of record of the property/properties identified herein, do authorize representatives of the Wilmington District, U.S. Army Corps of Engineers (Corps) and Summit Design and Engineering Services, LLC. staff, as my agent, to enter upon the property herein described for the purpose of conducting on -site investigations and issuing a determination associated with Waters of the U.S. subject to Federal jurisdiction under Section 404 of the Clean Water Act and/or Section 10 of the Rivers and Harbors Act of 1899. This document also authorizes Summit Design, as my agent, to act on my behalf and take all actions necessary for the processing, issuance and acceptance of a permit or certification and any and all associated standard and special conditions. This notification supersedes any previous correspondence concerning the agent for this project. NOTICE: This authorization, for liability and professional courtesy reasons, is valid only for government officials to enter the property when accompanied by Summit Design staff. PARCEL INFORMATION: Parcel Index Number(s) (PIN): 9864659601 Site Address: 206 S. Nash Street Unit 104 City, County, State: Hillsborough, Orange, NC 27278 PROPERTY OWNER INFORMATION: Name: Bellevue Mill LLC Mailing Address: 8380 Bay Pines Blvd 3'a Floor St. Petersburg, FL 33709 ° Property Owner (please print) a aA -^'S �D oL)3o ��z^ Property Owner Signature We hereby certify the above information submitted in this application is true and accurate to the best of our knowledge. 515 520 525 530 515 520 525 530 0+00523.2523.190+50521.8521.840+72.51 STA:0+25 ELEV: 524.4' STA:0+47 ELEV: 524.4' STA:0+25 ELEV: 522.4'STA:0+47 ELEV: 521.8' STA:0+27 ELEV: 518.4' STA:0+42 ELEV: 518.9' SA SA SA 0+00 0+72 Dual 10" Tree 16" Tree 16" Tree 16" Tree BELLVUE BRIDGE DRAWING ALTERATION IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF LICENSED ARCHITECT, PROFESSIONAL ENGINEER, LANDSCAPE ARCHITECT, OR LAND SURVEYOR TO ALTER ANY ITEM ON THIS DOCUMENT IN ANY WAY. ANY LICENSEE WHO ALTERS THIS DOCUMENT IS REQUIRED BY LAW TO AFFIX HIS OR HER SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS OR HER SIGNATURE AND SPECIFIC DESCRIPTION OF THE ALTERATIONS. COPYRIGHT 2020 SUMMIT DESIGN AND ENGINEERING SERVICES C PROJECT NO. SCALE SHEET NO. FIRST ISSUE DATE HILLSBOROUGH, NC C r e a t i v e l y I n s p i r e d - T e c h n i c a l l y E x e c u t e d License #: P-0339 320 Executive Drive Hillsborough, NC 27278-8551 Voice: (919) 732-3883 Fax: (919) 732-6676 www.summitde.net 1"=20' 05-15-2020 20-0093.010 EXHIBIT 1 STREAM CROSSING PLAN AND PROFILE 6' WIDE BRIDGE 25' SPAN 6' WIDE APPROACH SLAB 10' LONG APPROXIMATE LOCATION OF 6' WIDE MULCH TRAIL IN 10' EASEMENT (TO BE DETERMINED IN FIELD) APPROXIMATE LOCATION OF 6' WIDE MULCH TRAIL (TO BE DETERMINED IN FIELD)10' IMPACTS ZONE 1 PERMANENT: 650 SF ZONE 2 PERMANENT: 444 SF ZONE 1 TEMPORARY: 1285 SF ZONE 2 TEMPORARY: 891 SF 6" COMPACTED ABC SUITABLE FILL AND/OR #57 STONE 6' 6" CONC. SIDEWALK CONCRETE APPROACH SLAB DETAIL NTS BRIDGE SECTIONS 1"=20' 24'4'6'7'6'SEVENMILE CREEK 2' - 0"2' - 0"2' - 0"A S100 PT 3X16.5 GLULAM GIRDER, TYP. PT 2X12 BLOCKING AT GIRDER THIRD POINTS CONC. APPROACH SLAB, PER CIVIL, TYP. TYP.6"TYP.5' - 0"TYP.5' - 0"CONC. BRIDGE ABUTMENT, TYP. W.P.#1 STA: 0+25 EL = 524.4' W.P.#2 STA: 0+47 EL = 524.4'SEVENMILE CREEK4X6 GUARDRAIL POST @ 4'-0" O.C. MAX, TYP. B S100 PT 2X6 DECKING S100 C 6' - 3"CONC. ABUTMENT FOOTING, TYP. 3' - 6"1' - 6" WALL 10" CONC.1' - 0"STEM 5" CONC. 1/2" BOND BREAK MAT'L CONC. APPROACH. SEE CIVIL DWGS PT 2X6 WOOD DECKING PT GLULAM GIRDER, PER PLAN SIMPSON HGLA (W=3-1/4") CAST-IN-PLACE BEAM SEAT, HOT DIPPED-GALVANIZED, W/ (2) 3/4" THRU BOLTS 1' - 4" MIN.GRADE EL = PER CIVIL±7'-6" WALL HEIGHTCLR.2"CLR.3"TYP. 3" CLR. TYP. 2" CLR.TYP.2" CLR.#5 @12" O.C. BARS @ T&B, EA. WAY #4 BARS @ 12" O.C. EA. WAY, EA. FACE 1/2" GAP W.P. STA. & ELE., PER PLAN 3"3' - 6"3' - 1 1/2"3' - 1 1/2" PT 2X6 DECKING, MIN. (2) #10 X 3" GALV. SCREWS PER BOARD, PER GIRDER PT 2X4 RAIL, TYP.PT 4X6 GUARDRAIL POSTS @ 4'-0" O.C. (3) 3/4"Ø GALV. THRU BOLTS @ EA. POST W/ WASHER EA. SIDE PT GLULAM GIRDER, PER PLAN PT 2X12 BLOCKING AT GIRDER THIRD POINTS PT 2X8 TOP BOARD @ 30 DEG. SLANT, TYP.5"5"3"GAP3 1/2" MAX.6' - 0" CLEAR PT 2X12 JOIST, SEE PLAN, TYP. PT 4X6 POST, TYP.PT 2X6 DECKING, MIN. (2) GALV. SCREWS PER BOARD PER JOIST PT 2X8 TOP BOARD @ 30 DEG SLANT 3' - 6"3"GAP3 1/2" MAX.PT 2X4 RAIL, TYP. H OF N ENRPROT R NGI E EOL AN LO 043287 AS E L A SES C R I AI NJ . WES T A Y L O RState License #: P-03391110 Navaho Drive, Suite 600 Raleigh, NC 27609 Voice: (919) 322-0115 Fax: (919) 322-0116 www.SummitDE.netPROJECT NO. DRAWN BY: FIRST ISSUE DATE:COPYRIGHT © 2020 SUMMIT DESIGN AND ENGINEERING SERVICES, THIS DRAWING & THE DESIGN INTENT OF THIS INSTRUMENT OF SERVICE IS THE VESTED PROPERTY OF THE ENGINEER, WHICH ARE NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT EXPRESS WRITTEN CONSENT OF THE ENGINEER. CHECKED BY:6/25/2020 5:09:20 PM Z:\20-0093\02_Working Drawings\20-0093 - Bellvue Bridge_R19.rvt20-0093.400 S100 06/26/2020 JWT PLANS & DETAILS HILLSBOROUGH, NCSTREAM CROSSING OVER SEVENMILE CREEKBELLVUE BRIDGECCB 06/26/2020 1/2" = 1'-0"1 BRIDGE FRAMING PLAN 3/4" = 1'-0"A ABUTMENT SECTION 3/4" = 1'-0"B BRIDGE SECTION 1/2" = 1'-0"C TYPICAL GUARDRAIL ELEVATION D E S I G N C R I T E R I A BUILDING CODE:NORTH CAROLINA STATE BUILDING CODE, 2018 EDITION CONCRETE DESIGN CODE: ACI 318-14, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE CONCRETE DESIGN METHOD: EQUIV. RECTANGULAR STRESS BLOCK STEEL DESIGN CODE:AISC 360-10, SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS, LRFD STEEL DESIGN METHOD:ELASTIC ANALYSIS, PLASTIC DESIGN W I N D L O A D BASIC WIND SPEED:115 MPH WIND IMPORTANCE FACTOR (IW): 1.0 OCCUPANCY CATEGORY: II WIND EXPOSURE CATEGORY: C ANALYSIS PROCEDURE:ENVELOPE PROCEDURE - ENCLOSED SIMPLE DIAPHRAGM LOW-RISE BUILDINGS COMPONENTS & CLADDING PRESSURES: CALCULATED PER ASCE 7-10 S E I S M I C L O A D STRUCTURE OCCUPANCY CATEGORY: II SEISMIC IMPORTANCE FACTOR (IE): 1.0 MAPPED SPECTRAL RESPONSE ACCELERATION (SS): 15.4% MAPPED SPECTRAL RESPONSE ACCELERATION (S1): 7.7% SITE CLASS: D DESIGN SPECTRAL RESPONSE ACCELERATION (SDS): 16.4% DESIGN SPECTRAL RESPONSE ACCELERATION (SD1): 12.3% SEISMIC DESIGN CATEGORY: B BASIC SEISMIC FORCE RESISTING SYSTEM: NOT SPECIFICALLY DETAILED FOR SEISMIC RESISTANCE ANALYSIS PROCEDURE:EQUIVALENT LATERAL FORCE PROCEDURE L I V E L O A D S PEDESTRIAN:100 PSF G E N E R A L N O T E S 1. THE STRUCTURAL DRAWINGS ARE TO BE USED IN CONJUNCTION WITH ARCHITECTURAL, CIVIL, MECHANICAL AND ELECTRICAL DRAWINGS. 2. THE CONTRACTOR SHALL COORDINATE BETWEEN ALL TRADES. CONFLICTS BETWEEN THE STRUCTURAL DRAWINGS AND THE DRAWINGS OF OTHERS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE STRUCTURAL ENGINEER IN A TIMELY FASHION THAT PERMITS CLARIFICATIONS WITHOUT EFFECTING THE CONSTRUCTION SCHEDULE. 3. THESE DRAWINGS, ALONG WITH ANY SPECIFICATIONS ISSUED, CONSTITUTE THE CONTRACT DESIGN DOCUMENTS FOR THIS PROJECT. ANY DISCREPANCY BETWEEN THE TWO SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT OR STRUCTURAL ENGINEER FOR CLARIFICATION. FOR ESTIMATING PURPOSES THE CONTRACTOR SHALL ASSUME THE MORE COSTLY ALTERNATIVE. NO MATERIALS MAY BE ORDERED, AND NO WORK MAY PROCEED UNTIL THE DISCREPANCY IS RESOLVED BY THE DESIGN PROFESSIONAL. 4. ALTERNATES OR SUBSTITUTIONS TO STRUCTURAL MATERIALS OR DESIGN ARE AT THE SOLE DISCRETION OF THE LICENSED STRUCTURAL ENGINEER OF RECORD. ANY MODIFICATION MUST BE APPROVED IN THE MANNER SET FORTH IN THE "FRONT END" SPECIFICATIONS. 5. ALL STANDARDS REFERENCED WITHIN THESE DOCUMENTS ARE TO BE THE EDITIONS REFERENCED IN CHAPTER THIRTY-FIVE OF THE INTERNATIONAL BUILDING CODE. 6. STRUCTURAL MEMBERS, INCLUDING BEAMS, COLUMNS, JOISTS, TRUSSES, WALLS, SLABS AND BRACING ELEMENTS, ARE DESIGNED FOR THE FINAL DESIGN LOADS GIVEN ON THIS SHEET. THE CONTRACTOR IS RESPONSIBLE FOR ALL TEMPORARY SHORING AND BRACING. SHORING IS TO BE DESIGNED TO PRECLUDE THE OVERSTRESSING ANY STRUCTURAL ELEMENT (AS REQUIRED AT ANY STAGE OF CONSTRUCTION) UNTIL COMPLETION OF THIS PROJECT. 7. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ON-SITE SAFETY. AT A MINIMUM, THE CONTRACTOR IS TO RESEARCH AND IMPLEMENT ALL SAFETY REGULATIONS IN FORCE IN THE JURISDICTION OF THIS PROJECT. PRIOR TO THE COMMENCEMENT OF WORK, THE CONTRACTOR SHALL BRING TO THE ATTENTION OF THE STRUCTURAL ENGINEER ANY STRUCTURAL DETAIL THAT WOULD PRODUCE AN UNUSUALLY UNSAFE CONDITION. C O N C R E T E 1. ALL CONCRETE WORK SHALL COMPLY WITH THE SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS, ACI-301 AND THE BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE, ACI-318 (EDITIONS IN FORCE). 2. CONCRETE MIX DESIGNS ARE REFERENCED IN THE PROJECT SPECIFICATIONS. FOR EACH DESIGN A SUBMITTAL SHALL BE MADE BY THE CONTRACTOR AS OUTLINED IN THE SPECIFICATIONS. 3. ALL REINFORCING STEEL IS TO BE TIED TO PREVENT DISPLACEMENT DURING CONCRETE PLACEMENT. TACK WELDING OF REINFORCEMENT STEEL IS PROHIBITED. 4. THE CONTRACTOR SHALL SUBMIT A COMPLETE LIST OF ACCESSORIES AND PLACING DETAILS WITH SHOP DRAWINGS. 5. ALL REINFORCING STEEL IS TO BE CONTINUOUS. LAP BARS 40 DIAMETERS FOR BARS #6 AND SMALLER OR 48 DIAMETERS FOR BARS #7 AND LARGER AT SPLICE UNLESS NOTED OTHERWISE ON SCHEDULES OR DETAILS. 6. THE LOCATION OF ALL LAP SPLICES WILL BE SHOWN ON SHOP DRAWINGS. 7. NO CONCRETE ELEMENT MAY BE CORED TO PLACE THROUGH ITEMS (ie PIPES, ELECTRICAL LINES, ETC.). ALL THROUGH ITEMS PENETRATING HORIZONTAL SURFACES ARE TO BE PLACED IN SCHEDULE 40, STEEL, PIPE SLEEVES OF A DIAMETER SUFFICIENT TO ACCOMMODATE THE THROUGH ITEM. AT PENETRATIONS IN THE VERTICAL PLANE OF ELEMENTS THE PIPE SLEEVE DIAMETER WILL BE INCREASED BY AN AMOUNT TO PROVIDE 1 1/2" CLEAR DIMENSION AROUND THE THROUGH ITEM. 8. REFER TO ARCHITECTURAL DRAWINGS FOR ALL WATERPROOFING OF CONCRETE BELOW GRADE. 9. NO HORIZONTAL CONSTRUCTION JOINTS ARE PERMITTED IN CONCRETE ELEMENTS. LOCATE VERTICAL CONSTRUCTION JOINTS AT THE MIDDLE THIRD OF THE SPAN. PROVIDE 2x4, CONTINUOUS, BEVELED KEYWAYS AT SLABS AND (ONE MINIMUM) AND 2X8 BEVELED KEYWAY AT BEAMS. SUBMIT PROPOSED CONSTRUCTION JOINT LOCATIONS TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR APPROVAL. 10. ALL INTERSECTING BEAMS, WALLS, AND FOOTINGS SHALL HAVE CORNER BARS. REFER TO TYPICAL DETAILS. 11. TYPICAL REINFORCING CLEAR COVER SHALL CONFORM TO ACI 318 (EDITIONS IN FORCE), U.N.O. F O U N D A T I O N S 1. THE PRIMARY BUILDING STRUCTURE IS DESIGNED FOR SUPPORT ON SPREAD FOOTINGS WITH AN ASSUMED ALLOWABLE NET SOIL BEARING PRESSURE OF 2000 PSF ON UNDISTURBED SOILS OR COMPACTED FILL. 2. IF SOIL AT THE SCHEDULED FOOTING ELEVATION IS OF QUESTIONABLE BEARING VALUE, THE ARCHITECT AND STRUCTURAL ENGINEER ARE TO BE NOTIFIED IMMEDIATELY. LOWER FOOTING ELEVATIONS IF REQUIRED BY ARCHITECT AND ENGINEER TO REACH FIRM SOIL. 3. CONTRACTOR IS TO PROVIDE PROPERLY DESIGNED SHEETING AND SHORING AT ALL OPEN EXCAVATIONS, OR LAY BACK THE CUT AT A SLOPE APPROVED BY THE ON-SITE GEOTECHNICAL ENGINEER IN ORDER TO ENSURE SAFE WORKING CONDITIONS AND AS NECESSARY TO COMPLY WITH ALL APPLICABLE CODES AND REGULATIONS. ALL EXCAVATIONS SHALL BE ADEQUATELY DEWATERED BEFORE PLACEMENT OF CONCRETE. D I M E N S I O N A L L U M B E R 1. CODE FOR MEMBER DESIGN: ANSI/AF&PA NATIONAL DESIGN SPECIFICATION AND SUPPLEMENT. ALL MEMBERS SHALL BEAR AN APPROVED GRADE STAMP. 2. DESIGN IS BASED ON SP NO. 2 WITH DESIGN PROPERTIES ACCORDING TO THE SOUTHERN PINE 2013 ADDENDUM. 3. ALL DIMENSIONAL LUMBER SIZES SHOWN ON DRAWINGS ARE NOMINAL DIMENSIONS. 4. ALL LUMBER EXPOSED TO WEATHER SHALL BE PRESERVATIVE TREATED. S T R U C T U R A L C O M P O S I T E L U M B E R 1. CODE FOR MEMBER DESIGN: ANSI/AF&PA NATIONAL DESIGN SPECIFICATION AND SUPPLEMENT. ALL MEMBERS SHALL BEAR AN APPROVED GRADE STAMP. 2. STRUCTURAL COMPOSITE LUMBER (SCL) DESIGN IS BASED ON THE FOLLOWING MINIMUM DESIGN PROPERITES: • LVL: Fb = 2,600 PSI Fv = 285 PSI Fc⟂= 750 PSI E = 1,900 KSI • PSL: Fb = 2,400 PSI Fc = 2,500 PSI Fv = 190 PSI E = 1,800 KSI • GLULAM: 24F-V5 SP/SP 3. LVL AND PSL MEMBERS SHALL BE PROTECTED FROM WEATHER ACCORDING TO THEIR MANUFACTURER'S RECOMMENDATIONS. GLULAM BEAMS ARE TO BE PRESERVATIVE TREATED IF THEY ARE EXPOSED TO WEATHER. M A T E R I A L S 1. STEEL PLATES & BARS (GENERAL) ASTM A36, Fy = 36 KSI, HOT-DIPPED GALVANIZED BOLTS ASTM A36, HOT-DIPPED GALVANIZED ANCHOR RODS ASTM F1554 GRADE 36 2. REINFORCING STEEL GENERAL REINFORCING ASTM A615, Fy = 60 KSI 3. CONCRETE FOOTINGS MIX F'c = 3000 PSI NORMAL WEIGHT WALLS MIX F'c = 4500 PSI NORMAL WEIGHT NO REVISIONS DATE 515 520 525 530 515 520 525 530 0+00523.2523.190+50521.8521.840+72.51 STA:0+25 ELEV: 524.4' STA:0+47 ELEV: 524.4' STA:0+25 ELEV: 522.4'STA:0+47 ELEV: 521.8' STA:0+27 ELEV: 518.4' STA:0+42 ELEV: 518.9' SA SA SA 0+00 0+72 Dual 10" Tree 16" Tree 16" Tree 16" Tree BELLVUE BRIDGE DRAWING ALTERATION IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF LICENSED ARCHITECT, PROFESSIONAL ENGINEER, LANDSCAPE ARCHITECT, OR LAND SURVEYOR TO ALTER ANY ITEM ON THIS DOCUMENT IN ANY WAY. ANY LICENSEE WHO ALTERS THIS DOCUMENT IS REQUIRED BY LAW TO AFFIX HIS OR HER SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS OR HER SIGNATURE AND SPECIFIC DESCRIPTION OF THE ALTERATIONS. COPYRIGHT 2020 SUMMIT DESIGN AND ENGINEERING SERVICES C PROJECT NO. SCALE SHEET NO. FIRST ISSUE DATE HILLSBOROUGH, NC C r e a t i v e l y I n s p i r e d - T e c h n i c a l l y E x e c u t e d License #: P-0339 320 Executive Drive Hillsborough, NC 27278-8551 Voice: (919) 732-3883 Fax: (919) 732-6676 www.summitde.net 1"=20' 05-15-2020 20-0093.010 EXHIBIT 1 STREAM CROSSING PLAN AND PROFILE 6' WIDE BRIDGE 25' SPAN 6' WIDE APPROACH SLAB 10' LONG APPROXIMATE LOCATION OF 6' WIDE MULCH TRAIL IN 10' EASEMENT (TO BE DETERMINED IN FIELD) APPROXIMATE LOCATION OF 6' WIDE MULCH TRAIL (TO BE DETERMINED IN FIELD)10' IMPACTS ZONE 1 PERMANENT: 650 SF ZONE 2 PERMANENT: 444 SF ZONE 1 TEMPORARY: 1285 SF ZONE 2 TEMPORARY: 891 SF 6" COMPACTED ABC SUITABLE FILL AND/OR #57 STONE 6' 6" CONC. SIDEWALK CONCRETE APPROACH SLAB DETAIL NTS BRIDGE SECTIONS 1"=20' 24'4'6'7'6'SEVENMILE CREEK 2' - 0"2' - 0"2' - 0"A S100 PT 3X16.5 GLULAM GIRDER, TYP. PT 2X12 BLOCKING AT GIRDER THIRD POINTS CONC. APPROACH SLAB, PER CIVIL, TYP. TYP.6"TYP.5' - 0"TYP.5' - 0"CONC. BRIDGE ABUTMENT, TYP. W.P.#1 STA: 0+25 EL = 524.4' W.P.#2 STA: 0+47 EL = 524.4'SEVENMILE CREEK4X6 GUARDRAIL POST @ 4'-0" O.C. MAX, TYP. B S100 PT 2X6 DECKING S100 C 6' - 3"CONC. ABUTMENT FOOTING, TYP. 3' - 6"1' - 6" WALL 10" CONC.1' - 0"STEM 5" CONC. 1/2" BOND BREAK MAT'L CONC. APPROACH. SEE CIVIL DWGS PT 2X6 WOOD DECKING PT GLULAM GIRDER, PER PLAN SIMPSON HGLA (W=3-1/4") CAST-IN-PLACE BEAM SEAT, HOT DIPPED-GALVANIZED, W/ (2) 3/4" THRU BOLTS 1' - 4" MIN.GRADE EL = PER CIVIL±7'-6" WALL HEIGHTCLR.2"CLR.3"TYP. 3" CLR. TYP. 2" CLR.TYP.2" CLR.#5 @12" O.C. BARS @ T&B, EA. WAY #4 BARS @ 12" O.C. EA. WAY, EA. FACE 1/2" GAP W.P. STA. & ELE., PER PLAN 3"3' - 6"3' - 1 1/2"3' - 1 1/2" PT 2X6 DECKING, MIN. (2) #10 X 3" GALV. SCREWS PER BOARD, PER GIRDER PT 2X4 RAIL, TYP.PT 4X6 GUARDRAIL POSTS @ 4'-0" O.C. (3) 3/4"Ø GALV. THRU BOLTS @ EA. POST W/ WASHER EA. SIDE PT GLULAM GIRDER, PER PLAN PT 2X12 BLOCKING AT GIRDER THIRD POINTS PT 2X8 TOP BOARD @ 30 DEG. SLANT, TYP.5"5"3"GAP3 1/2" MAX.6' - 0" CLEAR PT 2X12 JOIST, SEE PLAN, TYP. PT 4X6 POST, TYP.PT 2X6 DECKING, MIN. (2) GALV. SCREWS PER BOARD PER JOIST PT 2X8 TOP BOARD @ 30 DEG SLANT 3' - 6"3"GAP3 1/2" MAX.PT 2X4 RAIL, TYP. H OF N ENRPROT R NGI E EOL AN LO 043287 AS E L A SES C R I AI NJ . WES T A Y L O RState License #: P-03391110 Navaho Drive, Suite 600 Raleigh, NC 27609 Voice: (919) 322-0115 Fax: (919) 322-0116 www.SummitDE.netPROJECT NO. DRAWN BY: FIRST ISSUE DATE:COPYRIGHT © 2020 SUMMIT DESIGN AND ENGINEERING SERVICES, THIS DRAWING & THE DESIGN INTENT OF THIS INSTRUMENT OF SERVICE IS THE VESTED PROPERTY OF THE ENGINEER, WHICH ARE NOT TO BE REPRODUCED IN WHOLE OR IN PART BY ANY MEANS OR METHOD WITHOUT EXPRESS WRITTEN CONSENT OF THE ENGINEER. CHECKED BY:6/25/2020 5:09:20 PM Z:\20-0093\02_Working Drawings\20-0093 - Bellvue Bridge_R19.rvt20-0093.400 S100 06/26/2020 JWT PLANS & DETAILS HILLSBOROUGH, NCSTREAM CROSSING OVER SEVENMILE CREEKBELLVUE BRIDGECCB 06/26/2020 1/2" = 1'-0"1 BRIDGE FRAMING PLAN 3/4" = 1'-0"A ABUTMENT SECTION 3/4" = 1'-0"B BRIDGE SECTION 1/2" = 1'-0"C TYPICAL GUARDRAIL ELEVATION D E S I G N C R I T E R I A BUILDING CODE:NORTH CAROLINA STATE BUILDING CODE, 2018 EDITION CONCRETE DESIGN CODE: ACI 318-14, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE CONCRETE DESIGN METHOD: EQUIV. RECTANGULAR STRESS BLOCK STEEL DESIGN CODE:AISC 360-10, SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS, LRFD STEEL DESIGN METHOD:ELASTIC ANALYSIS, PLASTIC DESIGN W I N D L O A D BASIC WIND SPEED:115 MPH WIND IMPORTANCE FACTOR (IW): 1.0 OCCUPANCY CATEGORY: II WIND EXPOSURE CATEGORY: C ANALYSIS PROCEDURE:ENVELOPE PROCEDURE - ENCLOSED SIMPLE DIAPHRAGM LOW-RISE BUILDINGS COMPONENTS & CLADDING PRESSURES: CALCULATED PER ASCE 7-10 S E I S M I C L O A D STRUCTURE OCCUPANCY CATEGORY: II SEISMIC IMPORTANCE FACTOR (IE): 1.0 MAPPED SPECTRAL RESPONSE ACCELERATION (SS): 15.4% MAPPED SPECTRAL RESPONSE ACCELERATION (S1): 7.7% SITE CLASS: D DESIGN SPECTRAL RESPONSE ACCELERATION (SDS): 16.4% DESIGN SPECTRAL RESPONSE ACCELERATION (SD1): 12.3% SEISMIC DESIGN CATEGORY: B BASIC SEISMIC FORCE RESISTING SYSTEM: NOT SPECIFICALLY DETAILED FOR SEISMIC RESISTANCE ANALYSIS PROCEDURE:EQUIVALENT LATERAL FORCE PROCEDURE L I V E L O A D S PEDESTRIAN:100 PSF G E N E R A L N O T E S 1. THE STRUCTURAL DRAWINGS ARE TO BE USED IN CONJUNCTION WITH ARCHITECTURAL, CIVIL, MECHANICAL AND ELECTRICAL DRAWINGS. 2. THE CONTRACTOR SHALL COORDINATE BETWEEN ALL TRADES. CONFLICTS BETWEEN THE STRUCTURAL DRAWINGS AND THE DRAWINGS OF OTHERS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE STRUCTURAL ENGINEER IN A TIMELY FASHION THAT PERMITS CLARIFICATIONS WITHOUT EFFECTING THE CONSTRUCTION SCHEDULE. 3. THESE DRAWINGS, ALONG WITH ANY SPECIFICATIONS ISSUED, CONSTITUTE THE CONTRACT DESIGN DOCUMENTS FOR THIS PROJECT. ANY DISCREPANCY BETWEEN THE TWO SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT OR STRUCTURAL ENGINEER FOR CLARIFICATION. FOR ESTIMATING PURPOSES THE CONTRACTOR SHALL ASSUME THE MORE COSTLY ALTERNATIVE. NO MATERIALS MAY BE ORDERED, AND NO WORK MAY PROCEED UNTIL THE DISCREPANCY IS RESOLVED BY THE DESIGN PROFESSIONAL. 4. ALTERNATES OR SUBSTITUTIONS TO STRUCTURAL MATERIALS OR DESIGN ARE AT THE SOLE DISCRETION OF THE LICENSED STRUCTURAL ENGINEER OF RECORD. ANY MODIFICATION MUST BE APPROVED IN THE MANNER SET FORTH IN THE "FRONT END" SPECIFICATIONS. 5. ALL STANDARDS REFERENCED WITHIN THESE DOCUMENTS ARE TO BE THE EDITIONS REFERENCED IN CHAPTER THIRTY-FIVE OF THE INTERNATIONAL BUILDING CODE. 6. STRUCTURAL MEMBERS, INCLUDING BEAMS, COLUMNS, JOISTS, TRUSSES, WALLS, SLABS AND BRACING ELEMENTS, ARE DESIGNED FOR THE FINAL DESIGN LOADS GIVEN ON THIS SHEET. THE CONTRACTOR IS RESPONSIBLE FOR ALL TEMPORARY SHORING AND BRACING. SHORING IS TO BE DESIGNED TO PRECLUDE THE OVERSTRESSING ANY STRUCTURAL ELEMENT (AS REQUIRED AT ANY STAGE OF CONSTRUCTION) UNTIL COMPLETION OF THIS PROJECT. 7. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ON-SITE SAFETY. AT A MINIMUM, THE CONTRACTOR IS TO RESEARCH AND IMPLEMENT ALL SAFETY REGULATIONS IN FORCE IN THE JURISDICTION OF THIS PROJECT. PRIOR TO THE COMMENCEMENT OF WORK, THE CONTRACTOR SHALL BRING TO THE ATTENTION OF THE STRUCTURAL ENGINEER ANY STRUCTURAL DETAIL THAT WOULD PRODUCE AN UNUSUALLY UNSAFE CONDITION. C O N C R E T E 1. ALL CONCRETE WORK SHALL COMPLY WITH THE SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS, ACI-301 AND THE BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE, ACI-318 (EDITIONS IN FORCE). 2. CONCRETE MIX DESIGNS ARE REFERENCED IN THE PROJECT SPECIFICATIONS. FOR EACH DESIGN A SUBMITTAL SHALL BE MADE BY THE CONTRACTOR AS OUTLINED IN THE SPECIFICATIONS. 3. ALL REINFORCING STEEL IS TO BE TIED TO PREVENT DISPLACEMENT DURING CONCRETE PLACEMENT. TACK WELDING OF REINFORCEMENT STEEL IS PROHIBITED. 4. THE CONTRACTOR SHALL SUBMIT A COMPLETE LIST OF ACCESSORIES AND PLACING DETAILS WITH SHOP DRAWINGS. 5. ALL REINFORCING STEEL IS TO BE CONTINUOUS. LAP BARS 40 DIAMETERS FOR BARS #6 AND SMALLER OR 48 DIAMETERS FOR BARS #7 AND LARGER AT SPLICE UNLESS NOTED OTHERWISE ON SCHEDULES OR DETAILS. 6. THE LOCATION OF ALL LAP SPLICES WILL BE SHOWN ON SHOP DRAWINGS. 7. NO CONCRETE ELEMENT MAY BE CORED TO PLACE THROUGH ITEMS (ie PIPES, ELECTRICAL LINES, ETC.). ALL THROUGH ITEMS PENETRATING HORIZONTAL SURFACES ARE TO BE PLACED IN SCHEDULE 40, STEEL, PIPE SLEEVES OF A DIAMETER SUFFICIENT TO ACCOMMODATE THE THROUGH ITEM. AT PENETRATIONS IN THE VERTICAL PLANE OF ELEMENTS THE PIPE SLEEVE DIAMETER WILL BE INCREASED BY AN AMOUNT TO PROVIDE 1 1/2" CLEAR DIMENSION AROUND THE THROUGH ITEM. 8. REFER TO ARCHITECTURAL DRAWINGS FOR ALL WATERPROOFING OF CONCRETE BELOW GRADE. 9. NO HORIZONTAL CONSTRUCTION JOINTS ARE PERMITTED IN CONCRETE ELEMENTS. LOCATE VERTICAL CONSTRUCTION JOINTS AT THE MIDDLE THIRD OF THE SPAN. PROVIDE 2x4, CONTINUOUS, BEVELED KEYWAYS AT SLABS AND (ONE MINIMUM) AND 2X8 BEVELED KEYWAY AT BEAMS. SUBMIT PROPOSED CONSTRUCTION JOINT LOCATIONS TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR APPROVAL. 10. ALL INTERSECTING BEAMS, WALLS, AND FOOTINGS SHALL HAVE CORNER BARS. REFER TO TYPICAL DETAILS. 11. TYPICAL REINFORCING CLEAR COVER SHALL CONFORM TO ACI 318 (EDITIONS IN FORCE), U.N.O. F O U N D A T I O N S 1. THE PRIMARY BUILDING STRUCTURE IS DESIGNED FOR SUPPORT ON SPREAD FOOTINGS WITH AN ASSUMED ALLOWABLE NET SOIL BEARING PRESSURE OF 2000 PSF ON UNDISTURBED SOILS OR COMPACTED FILL. 2. IF SOIL AT THE SCHEDULED FOOTING ELEVATION IS OF QUESTIONABLE BEARING VALUE, THE ARCHITECT AND STRUCTURAL ENGINEER ARE TO BE NOTIFIED IMMEDIATELY. LOWER FOOTING ELEVATIONS IF REQUIRED BY ARCHITECT AND ENGINEER TO REACH FIRM SOIL. 3. CONTRACTOR IS TO PROVIDE PROPERLY DESIGNED SHEETING AND SHORING AT ALL OPEN EXCAVATIONS, OR LAY BACK THE CUT AT A SLOPE APPROVED BY THE ON-SITE GEOTECHNICAL ENGINEER IN ORDER TO ENSURE SAFE WORKING CONDITIONS AND AS NECESSARY TO COMPLY WITH ALL APPLICABLE CODES AND REGULATIONS. ALL EXCAVATIONS SHALL BE ADEQUATELY DEWATERED BEFORE PLACEMENT OF CONCRETE. D I M E N S I O N A L L U M B E R 1. CODE FOR MEMBER DESIGN: ANSI/AF&PA NATIONAL DESIGN SPECIFICATION AND SUPPLEMENT. ALL MEMBERS SHALL BEAR AN APPROVED GRADE STAMP. 2. DESIGN IS BASED ON SP NO. 2 WITH DESIGN PROPERTIES ACCORDING TO THE SOUTHERN PINE 2013 ADDENDUM. 3. ALL DIMENSIONAL LUMBER SIZES SHOWN ON DRAWINGS ARE NOMINAL DIMENSIONS. 4. ALL LUMBER EXPOSED TO WEATHER SHALL BE PRESERVATIVE TREATED. S T R U C T U R A L C O M P O S I T E L U M B E R 1. CODE FOR MEMBER DESIGN: ANSI/AF&PA NATIONAL DESIGN SPECIFICATION AND SUPPLEMENT. ALL MEMBERS SHALL BEAR AN APPROVED GRADE STAMP. 2. STRUCTURAL COMPOSITE LUMBER (SCL) DESIGN IS BASED ON THE FOLLOWING MINIMUM DESIGN PROPERITES: • LVL: Fb = 2,600 PSI Fv = 285 PSI Fc⟂= 750 PSI E = 1,900 KSI • PSL: Fb = 2,400 PSI Fc = 2,500 PSI Fv = 190 PSI E = 1,800 KSI • GLULAM: 24F-V5 SP/SP 3. LVL AND PSL MEMBERS SHALL BE PROTECTED FROM WEATHER ACCORDING TO THEIR MANUFACTURER'S RECOMMENDATIONS. GLULAM BEAMS ARE TO BE PRESERVATIVE TREATED IF THEY ARE EXPOSED TO WEATHER. M A T E R I A L S 1. STEEL PLATES & BARS (GENERAL) ASTM A36, Fy = 36 KSI, HOT-DIPPED GALVANIZED BOLTS ASTM A36, HOT-DIPPED GALVANIZED ANCHOR RODS ASTM F1554 GRADE 36 2. REINFORCING STEEL GENERAL REINFORCING ASTM A615, Fy = 60 KSI 3. CONCRETE FOOTINGS MIX F'c = 3000 PSI NORMAL WEIGHT WALLS MIX F'c = 4500 PSI NORMAL WEIGHT NO REVISIONS DATE