HomeMy WebLinkAboutNCG210103_Inspection Report_20200701ROY COOPER Governor MICHAEL S. REGAN Secretary BRIAN WRENN Director Granite Hardwoods Inc. Attention: Jim Caldwell Post Office Box 226 Granite Falls, North Carolina 28630 NORTH CAROLINA Environmental Quality July 1, 2020 Subject: Compliance Evaluation Inspection Permit: NCG210000 Certificate of Coverage: NCG210103 Rutherford County, North Carolina Dear Caldwell: Enclosed please find a copy of the Compliance Evaluation Inspection Report for the inspection I conducted at the subject facility on June 24, 2020. The report should be self-explanatory; however, should you have any questions concerning this report, please do not hesitate to contact me at (828) 296-4500 or by email at Isaiah.reed@ncdenr.gov. Sincere Isaiah Reed, CPSWQ, CEPSCI, MS4CECI Environmental Specialist Land Quality Section Enclosure: Inspection Report D ��� North Carolina Department of Environmental Quality I Division of Energy, Mineral and Land Resources Asheville Regional Office 1 2090 U.S. Highway 70 1 Swannanoa, North Carolina 28778 oe°n. "�"�nm.�um�aro 828.296A500 Compliance Inspection Report Permit: NCG210103 Effective: 08/01/18 Expiration: 07/31/23 Owner: Granite Hardwoods Inc SOC: Effective: Expiration: Facility: Granite Hardwoods Incorporated County: Caldwell Hwy 321 A Region: Asheville Granite Falls NC 28630 Contact Person: Jim Caldwell Title: Phone:828-396-3395 Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 06/24/2020 Primary Inspector: Isaiah L Reed Secondary Inspector(s): Certification: Phone: Entry Time 03:OOPM Exit Time: 04:OOPM Phone: 828-296-4614 Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Timber Products Stormwater Discharge COC Facility Status: ❑ Compliant Not Compliant Question Areas: M Storm Water (See attachment summary) Page 1 of 3 Permit: NCG210103 Owner - Facility: Granite Hardwoods Inc Inspection Date: 06/24/2020 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary On June 24, 2020 this facility was inspected for compliance. I met with Jim Caldwell on site. During the inspection, the following items were noted: 1) An updated list of significant spills and leaks has not been maintained. The permittee is directed to immediately begin maintaining a list of spills and leaks as outlined in the NCG210000 General Permit. 2) Facility inspections have not been documented. The permittee is directed to immediately begin documenting facility inspections as outlined in the NCG210000 General Permit. 3) Annual certification that the stormwater outfalls have been evaluated for the presence of non-stormwater discharge has no been documented. The permittee is directed to immediately begin documenting and conducting non-stormwater discharge evaluations as outlined in the NCG210000 General Permit. 4) Analytical Monitoring has not been documented or performed at the facility. The permittee is directed to immediately begin analytical monitoring as outlined in the NCG210000 General Permit. Please give the above items your immediate attention. If you have any questions, please contact this office at (828) 296-4614 Page 2 of 3 Permit: NCG210103 Owner- Facility: Granite Hardwoods Inc Inspection Date: 06/24/2020 Inspection Type : Compliance Evaluation Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? 0 ❑ ❑ ❑ # Does the Plan include a General Location (USGS) map? E ❑ ❑ ❑ # Does the Plan include a "Narrative Description of Practices"? ❑ ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? ❑ ❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? ❑ 0 ❑ ❑ # Has the facility evaluated feasible alternatives to current practices? 0 ❑ ❑ ❑ # Does the facility provide all necessary secondary containment? ❑ ❑ ❑ # Does the Plan include a BMP summary? ❑ ❑ ❑ # Does the Plan include a Spill Prevention and Response Plan (SPRP)? ❑ ❑ ❑ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? 0 ❑ ❑ ❑ # Does the facility provide and document Employee Training? ❑ ❑ ❑ # Does the Plan include a list of Responsible Party(s)? ❑ ❑ ❑ # Is the Plan reviewed and updated annually? ❑ ❑ ❑ # Does the Plan include a Stormwater Facility Inspection Program? ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? ❑ 0 ❑ ❑ Comment: See summary for more information Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? 0 ❑ ❑ ❑ Comment: Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? ❑ 0 ❑ ❑ # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ❑ ❑ E ❑ Comment: See summary for more information. Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? 0 ❑ ❑ ❑ # Were all outfalls observed during the inspection? 0 ❑ ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? ❑ ❑ ❑ # Has the facility evaluated all illicit (non stormwater) discharges? ❑ 0 ❑ ❑ Comment: Page 3 of 3