HomeMy WebLinkAboutWQ0022052_Monitoring - 02-2020_20200310-FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page of
Permit No.: WQ0022052
Facility Name: Hampstead Pines
County: Pender
Month: February
Year: 2020
PPI: 001
Flow Measuring Point: ❑ Influent [ 1 Effluent ❑ No flow generated
Parameter Monitoring Point: ❑ Influent O Effluent ❑ Groundwater Lowering ❑ Surface Water
Parameter Code
50050
00310
50060
31616
00610
00625
00620
00400
00665
00530
00076
00600
00010
70300
00940
m
Q E
O
C
Oa)
F
O
O
�
O
7 C
O N O
E
d-
V U
C
E
E
Q
r
N
Y 2
coZ
0
y
.`.
Z
O.
O
O C'
~ O
s
a
a N
O O O
~ 3rn
fn
21
Z
7
H
d
O 2
E-._
Z
fC
Q
E
d
> N
O VOl O
F- w�
p
'O
O
r
U
24-hr
hrs
GPD
mg/L
mg/L
#/100 mL
mg/L
mg/L
mg/L
su
mg/L
mg/L
NTU
mg/L
°C
mg/L
mg/L
1
6,239
<6
2
6,239
<6
3
07:55
1.25
7,342
>2.20
7.33
0.88
14.1
4
08:15
1
4,720
>2.20
7.73
1.31
15.8
5
07:35
1.25
4,518
>2.20
7.41
1.38
18
6
07:45
1
5,884
>2.20
7.62
1.46
18.4
7
07:30
1
5,029
>2.20
7.63
1.81
18.4
8
5,029
<6
9
5,029
<6
10
07:35
1
2,787
>2.20
7.67
2.3
11.2
11
08:30
1
2,516
>2.20
7.72
1.79
17.4
12
07:30
1
6,843
>2.20
7.69
1.42
19.2
131
07:30
1.25
4,116
<2
>2.20
<2
<0.2
0.8
0.87
7.62
0.09
<2.6
1.61
1.7
20.1
14
07:50
1
6,893
>2.20
7.62
1.3
16.8
15
6,893
<6
16
6,893
<6
17
08:55
1
1,571
>2.20
7.72
1.19
14.4
18
07:35
1.25
6,112
>2.20
7.78
1.48
15.2
191
07:30
1.5
4,327
>2.20
7.78
1.18
17.6
201
07:35
1
4,942
>2.20
7.84
1.58
14.5
21
07:30
1
5,971
>2.20
7.8
1.76
10.7
22
5,971
U rA
<6
23
5,971
<6
24
08:40
1.25
6,964
>2.20
7.75
2.9
14.6
25
07:30
1.5
5,237
>2.20
7.73
2.41
14.9
26
07:35
1.25
4.851
>2.20
7.59
2.24
19.9
27
07:30
1
57814
>2.20
7.7
1.71
15.5
28
07:30
1.5
6,129
>2.20
7.53
1.63
13
29
6,129
<6
30
31
Average:
5,412
0.00
0.00
1.00
0.00
0.80
0.87
0.09
0.00
1.15
1.70
15.99
Daily Maximum:
7,342
2.00
0.00
2.00
0.20
0.80
0.87
7.84
0.09
2.60
6.00
1.70
20.10
Daily Minimum:
1,571
2.00
0.00
2.00
0.20
0.80
0.87
7.33
0.09
2.60
0,88
1.70
10.70
Sampling Type:
Recorder
Composite
Composite
Grab
Grab
Composite
Composite
Grab
Composite
Composite
Recorder
Monthly Limit:
730,360
10
14
4
5
Daily Limit: 1
23,560
15
25
6
6-9
10
10
Sample Frequency: 1
Continuous
1X MTH
3 x Year
5 x Week
1 X MTH
1X MTH
1X MTH I
5 x Week
3 x Year
1X MTH
Continuous
FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page of
Sampling Person(s) Certified Laboratories
Name: J. marty Fritz Name: Enviromental Chemists
Name: Name:
Does all monitoring data and sampling frequencies meet the requirements in Attachment A of your permit? El Compliant ❑ Non -Compliant
If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective
action(s) taken. Attach additional sheets if necessary.
Operator in Responsible Charge (ORC) Certification
Permittee Certification
ORC: J. Marty Fritz
Permittee: HAMPSTEAD PINES HOA
Certification No.: 998158
Signing Official: Dennis Maurer
Grade: WW3 Phone Number: 910-319-0037
Signing Official's Title: President
Has ORC changed since previous NDARA? ❑ yes [I No
Phone Number: 248-981-8783 Permit Expiration: 9/30/2022
v2v
IV
1
J
Signature Date
Signature Date
By this signature, I certify that this report is accurrate and complete to the best of my knowledge.
I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in
accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information
submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for
gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am
aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for
knowing violations.
-
Mail Original and Two Copies to:
Division of Water Quality
Information Processing Unit
1617 Mail Service Center
Raleigh, North Carolina 27699-1617
-FORM: NDAR-1 10-13 NON -DISCHARGE APPLICATION REPORT (NDAR-1) Page of
Permit No.: W00022052
Facility Name: HAMPSTEAD PINES HOA
County: Pender
Month: February
Year: 2020
Did irrigation
Field Name:
1
Field Name:
Field Name:
Field Name:
occur
Area (acres):
3.8
Area (acres):
Area (acres):
Area (acres):
at this facility?
Cover Crop:RYE
Cover Crop:
p�
Cover Crop:
p�
Cover Crop:
P:
1Z YES ❑ No
Hourly Rate (in):
0.16
Hourly Rate (in):
Hourly Rate (in):
Hourly Rate (in):
Annual Rate (in):
88.07
Annual Rate (in):
Annual Rate (in):
Annual Rate (in):
Weather
Freeboard
Field Irrigated?
❑ YES ❑ No
Field Irrigated?
❑ YES ❑ No
Field Irrigated?
❑ YES ❑ No
Field Irrigated?
❑ YES ❑ NO
0
°
O
`
d
W
N
Q.
E
N
°
N
Q
.0
N
a
m
Ol
0
w
" _
m
N
D 2
T a
M N
�
m o
E N
_3 Q
O CL
> a
v
G?
E�
F.. '�
0
T C
� m
0 O
J
E 0
O` C
X O�
N 2 °
2 J
m
E N
O O-
O O.
> Q
v
N w
� C7
F 'C
0
T C
� m
O O
J
E a)
7` C
K O t6
t6 2 0
J
m a
E N
O O-
O Q
> Q
0
d a0,,
��
~
=
0
�. C
� �v
O
J
E a)
7 L C
X O�
R Y °
rL J
m a
E N
3a
O Q.
� Q
0
N .Oi
E�
F •�
_
rn
T C
��
D O
J
E rn
7` C
X OM
m 2 0
2 J
OF
in
ft
ft
gal
min
in
in
gal
min
in
in
gal
min
in
in
gal
min
in
in
1
0
2
0
3
C
50
1.5
5.00
6.38
29,400
146.27
0.28
0.12
4
PC
61
0
5.13
6.38
56,400
280.6
0.55
0.12
5
CL
61
0
5.21
6.38
0
6
CL
65
0
5.19
6.38
0
7
PC
61
3
5.10
6.13
0
8
0
9
33,500
166.67
0.32
0.12
10
C
41
0
1 5.13
6.13
58,900
293.03
0.57
0.12
11
CL
66
0
5.27
6.13
1 0
12
CL
63
0
5.25
6.13
0
13
PC
70
0
5.23
6.13
33,100
164.68
0.32
0.12
141
CL 1
50
0
5.29
6.13
0
15
27,300
135.82
0.26
0.12
16
0
17
CL
50
0.25
5.23
6.11
0
18
PC
46
0
5.17
6.11
0
19
R
61
0.25
5.15
6.09
39,100
194.53
0.38
0.12
201
CL
48
0
5.10
6.09
0
21
CL
34
1.2
5.06
5.99
52,300
260.2
0.51
0.12
22
0
23
0
24
CL
52
0
5.00
5.99
51,800
257.71
0.50
0.12
25
R
57
0.25
5.15
5.94
0
26
CL
63
0.25
5.10
5.90
0
271
C
45
0
5.06
5.90
53,800
267.66
0.52
0.12
28
C
38
0
4.58
5.90
7,500
37.313
0.07
0.07
29
0
30
0
31
0
Monthly Loading:
443,100
J4.29
0
0.00
012
Month Floating Total (in):
Ej
WOMEN �15111
PENEINIMN
FORM: NDAR-1 10-13
NON -DISCHARGE APPLICATION REPORT (NDAR-1)
Page of
Did the application rates exceed the limits in Attachment B of your permit?
Were adequate measures taken to prevent effluent ponding in or runoff from the sites?
Was a suitable vegetative cover maintained on all sites as specified in your permit?
Were all setbacks listed in your permit maintained for every application to each permitted site?
Were all freeboards maintained in accordance with the specified freeboard heights in your permit?
El Compliant ❑ Non -Compliant
El Compliant ❑ Non -Compliant
E) Compliant ❑ Non -Compliant
El Compliant ❑ Non -Compliant
O Compliant ❑ Non -Compliant
If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective
action(s) taken. Attach additional sheets if necessary.
Operator in Responsible Charge (ORC) Certification
Permittee Certification
ORC: J. MARTY FRITZ
Permittee: HAMPSTEAD PINES HOA
Certification No.: 995923
Signing Official: Dennis Maurer
Grade: SI Phone Number: 910-319-0037
Signing Official's Title: President
Has the ORC changed since the previous NDAR-17 ❑ Yes i] No
Phone N mber: 248-981-8783 Permit Exp.: 9/30/22
3 (%0
20 R a
Signature Date
Signature Date
By this signature, I certify that this report is accurrate and complete to the best of my knowledge.
I ce under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance
w system designed to assure that all qualified personnel properly gathered and evaluated the information submitted. Based on my
inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the
information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant
penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations.