HomeMy WebLinkAboutNC0084212_Regional Office Historical File Pre 2016Water Resources ENVIRONMENTAL QUALITY December 17, 2015 Mr. Johnny Lambert, Director Davie County Public Utilities 298 E. Depot Street, Suite 200 Mocksville, NC 27028 SUBJECT: Compliance Evaluation Inspection Sparks Road WTP Discharge NPDES Permit No. NCO084212 Davie County Dear Mr. Lambert: PAT MCCRORY Govemor DONALD R. VAN DER VAART Secretary S. JAY ZIMMERMAN Director On December 15, 2015, Mike Mickey of this office met with Matt Seats and Michael Weir, ORC, to perform a Compliance Evaluation Inspection of the NPDES wastewater discharge from the Sparks Road Water Treatment Plant (WTP). The inspection findings are detailed below and an inspection checklist is attached. I. Permit The NPDES permit expires next on May 31, 2019. Permit condition A.(3) required the submittal of electronic discharge monitoring reports (eDMRs) on or before April 1, 2015. The first electronic DMR for the Sparks Road facility was submitted for February 2015, well ahead of the above deadline. H. Self -Monitoring Proeram The inspection reviewed DMRs that were submitted for the period January 2015 through November 2015. The Sparks Road WTP was found to be compliant with all effluent limits during this period (see data summary attached), except for a daily maximum and monthly average TSS violation that occurred in October. These violations will be addressed in subsequent correspondence from this office. With regards to the permit monitoring requirements, it was noted that all sampling was being performed per the frequencies specified in the permit. III. Flow Measurement The NPDES permit requires continuous flow recording and an annual calibration of the flow measuring device. The effluent flow values reported on the DMRs are measured using an ultrasonic meter with parshall flume. The meter was last calibrated by Fortech on August 17, 2015. IV. Sludge Handling and Disposal Solids collected in the settling lagoons are land applied under non -discharge permit No. WQ0028806. The residuals were last removed by EMA Resources in 2010. Accumulated solids may be removed from one lagoon in the spring of 2016. V. Operations and Maintenance The facility was competently operated and maintained. The only concern noted during the inspection involved the erosion along the banks of the settling lagoons. The lack of vegetation was resulting in high TSS and turbidity levels in the lagoon effluent after significant rainfall events. It is hoped that the banks can be lined with matting and gravel in 2016. State of North Carolina I Environmental Quality I Water Resources 450 West Hanes MITI Road, Suite 300, Winston-Salem, NC 27105 Phone: 336-776-9800 \ Intemet: www.nodenr.gov 1 Mr. Johnny Lambert Page 2 December 17, 2015 VI. Facility Site Review The treatment system components for the filter backwash and clarifier wastewater consist of the following: two 785,000 gallon settling lagoons operated in parallel, tablet dechlorinator and flow meter. VH. Records/Reports A comparison of the November 2015 DMR with the operator's field records for flow, pH and total residual chlorine along with the laboratory results from Statesville Analytical showed that all data was transcribed onto the DMR correctly. VM. Effluent/Receiving Waters The system discharges into a ditch leading to a tributary of the Yadkin River, class "WS-IV" waters in the Yadkin -Pee Dee River Basin. The effluent was clear on the day of inspection. Our office appreciates your efforts to comply with the NPDES permit. Should you have any questions concerning this report, please contact Mike Mickey or me at (336) 776-9800. Sincerely, Sherri V. Knight, PE Regional Supervisor Water Quality Regional Operations Section Division of Water Resources cc: Mike Weir (sparksrdwtp@yadtel.net) Central Files WSRO Permit: NCO084212 Owner - Facility: Sparks Road WfP Inspection Date: 12/15/2015 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ 0 ❑ application? Is the facility as described in the permit? N ❑ ❑ ❑ # Are there any special conditions for the permit? 0 ❑ ❑ ❑ Is access to the plant site restricted to the general public? ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? ❑ ❑ ❑ Comment: The NPDES permit was reissued August 1 2014 and expires next on May 31 2019. The current permit required that eDMR submittal begin on or before April 1 2015. Submittal began before the deadline with the February 2015 DMR. For the review period January 2015 through November 2015 the Sparks Road WTP was found to be compliant with all effluent limits and monitoring requirements, except for violation of the TSS daily maximum and monthly average limit in October. These exceedances were due to erosion around the settling lagoons that after heavy rainfall events. Plans are in the works to install matting and gravel to remedy the situation. A comparison of the November 2015 DMR with the corresponding operator's records (for flow, PH and total residual chlorine) and the laboratory data from Statesville Analytical (remainder of the parameters) showed that all values were transcribed correctly. Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ 0 ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Treatment components for the filter backwash and clarifier wastewater consists of the following: *Two 785,000 gallon settling lagoons in parallel. *Tablet dechlorination unit *Ultrasonic flow meter with parshall flume. Residuals from the lagoons are land applied under non -discharge permit No. W00028806. Approximately 270 dry tons were last removed from both lagoons in 2010. Solids may be removed from one lagoon Phis spring. De -chlorination Yes No NA NE Type of system ? Tablet Is the feed ratio proportional to chlorine amount (1 to 1)? ❑ ❑ 0 ❑ Is storage appropriate for cylinders? ❑ ❑ 0 ❑ # Is de -chlorination substance stored away from chlorine containers? ❑ ❑ M ❑ Comment: Page# 3 0 Permit: NCO084212 Inspection Date: 12/15/2015 De -chlorination Are the tablets the proper size and type? Are tablet de -chlorinators operational? Owner - Facility: Sparks Road WTP Inspection Type: Compliance Evaluation Yes No NA NE Number of tubes in use? 2 Comment: There are two dechlor tubes at the flow monitoring structure must prior to the flume. The last seven chronic toxicity tests were recorded as a "pass". The permit requires quarterly toxicity monitoring with no limit. Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? 0 ❑ ❑ ❑ Is flow meter calibrated annually? ❑ ❑ ❑ Is the flow meter operational? ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ M ❑ Comment: EfFluent flow is measured using an ultrasonic meter with parshall flume. The meter was last calibrated by Fortech on August 17, 2015. The average daily discharge from the Sparks Road WTP for the period 1/15 - 10/15 was 1.4 MGD Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ 0 ❑ Comment: The effluent is discharged to a ditch adjacent to the flow monitoring structure. The effluent was crystal clear on the day of the inspection. The ditch eventually leads to a tributary of the Yadkin River that is class "WS-W waters. The tributary loins with the river Oust downstream of the intake structure. Page# 4 Sparks Road WTP NPDES Permit No. NCO084212 Self -Monitoring Data Summary January 2015 — November 2015 Parameters Monthly Avg. Permit Limit Monthly Avg. Limit Violations per DMR Daily Maximum Permit Limit Daily Max. Limit Violations per DMR Flow (MGD) - NA - NA TSS (mg/L) 30.0 32.9 mgq for October 45.0 116 mg/! on 10/5/15 pH (S.U.) - NA (6.0-9.0) range None R. Chlorine (ug/L) - NA 17.0* None Turbidity (NTU) - NA - NA Manganese (ug/L) - NA - NA Flouride (mg/L) - NA - NA T. Iron (ug/L) - NA - NA T. Copper (mg/L) - NA - NA T. Zinc (mg/L) - NA - NA T. Phosphorus (mg/L) - NA - NA T. Nitrogen (mg/L) - NA - NA Chronic Toxicity (P/F) monitoring only" NA - NA * TRC values reported below 50 ug/L are considered compliant. *" Chronic Toxicity monitoring is a pass/fail test @ 90% with no limit. Mickey, Mike From: Scott, Michele Sent: Wednesday, September 09, 2015 12:39 PM To: Weaver, Charles; Moore, Tom; Hennessy, John; Mickey, Mike Cc: jlambert@daviecountync.gov Subject: FW: Owner Name Issue/eDMR for Davie County permits FYI below from Johnny Lambert. Michele From: Johnny Lambert [mailto:jlambert@daviecountync.gov] Sent: Wednesday, September 09, 2015 12:37 PM To: Scott, Michele Subject: RE: Owner Name Issue/eDMR for Davie County permits Michelle, The name was Davie County Water and was changed years ago to Davie County Public Utilities and all should be changed to reflect Davie County Public Utilities. Johnny Lambert Director Public Utilities of 298 E. Depot St, Suite 200 Mocksville, North Carolina 27028 Telephone: (336) 753-6091 Email: jlambert@daviecountync.gov From: Scott, Michele [mailto:michele.scott(a>ncdenr.gov] Sent: Wednesday, September 09, 2015 12:29 PM To: Johnny Lambert Subject: FW: Owner Name Issue/eDMR for Davie County permits From: Weaver, Charles Sent: Wednesday, September 09, 2015 11:30 AM To: Moore, Tom Cc: Scott, Michele; Hennessy, John; johnny.lambertCcbco.davie.nc.us; jim.stockert@co.davie.nc.us; Mickey, Mike Subject: RE: Owner Name Issue/eDMR for Davie County permits NC0084212: Most recent renewal application (4/24/2014) listed Davie County Water System as the Owner. Permit renewal was issued to Davie County Water System on 6/27/2014. 2009 renewal (11/13/2009) was issued to Davie County Public Utilities. 2004 renewal was issued to Davie County Water System NC0024872 — last ownership change application (5/26/2015) listed Davie County Public Utilities as the Owner. Permit renewal was issued to Davie County Public Utilities on 6/4/2015. 2009 renewal was issued to Davie County Water System 2004 renewal was issued to Davie County Water System The Davie County website refers to "Public Utilities — Water". The linked documents on the website don't address the Water System vs. Public Utilities issue. We need something from Davie County clarifying what Owner name they want to use. BIMS and the eDMR system can be fixed once, hopefully for good. CHW From: Moore, Tom Sent: Tuesday, September 08, 2015 10:19 AM To: Weaver, Charles Cc: Scott, Michele; Hennessy, John Subject: FW: Owner Name Issue/eDMR Charles, Michele is trying to register a facility that appears to have an issue with the owner name in BIMS. There are 2 permits, NCO028472 (Davie County Water System/Cooleemee WWTP) and NCO084212 (Davie County Public Utilities/Sparks Road WTP, and appears they should be under the same owner. NCO084212 has already registered and now they want to register NC0028472. Both permits should have registered when NCO084212 was registered but failed to do so due to having different owner names in BIMS, Davie County Water System and Davie County Public Utilities. The owner needs to reflect the same name for both in BIMS. Once this is corrected, we can manually add the other permit to eDMR. Please take a look at this and update one of the permits to reflect the correct owner name. Thanks .... Tom Thomas F. Moore Business and Technology Application Analyst Division of Water Resources / Information Technology Branch Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, NC 28405 Phone: (910) 796-7301 E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. AGo Green! Print this email only when necessary. Thank you for helping NCDENR be environmentally responsible. From: Scott, Michele Sent: Tuesday, September 08, 2015 9:59 AM To: Moore, Tom <tom.f.moore@ncdenr.gov> Cc: Smith, George <george.smith@ncdenr.gov> Subject: Owner Name Issue/eDMR Hi Tom, I'm in the process of registering Davie County Water System/Cooleemee WWTP (NC0024872) for eDMR. However, the other facility NCO084212 is registered for eDMR but it's listed as Davie County Public Utilities in BIMS. Both facilities are not showing up under Johnny Lambert's name under the verification report because of the difference in the names. Can you look into this? Thanks in advance. Michele E. Scott Division of Water Resources Information Processing Unit Supervisor 1617 Mail Service Center Raleigh, NC 27699-1617 919-807-6429 E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. North Carolina Department of Environment and Natural Resources Pat McCrory Governor January 23, 2015 Mr. Johnny Lambert Public Works Director County of Davie 298 E. Depot Street, Suite 200 Mocksville, NC 27028 SUBJECT: Compliance Evaluation Inspection Sparks Road WTP Discharge NPDES Permit No. NCO084212 Davie County Dear Mr. Lambert: Donald van der Vaart On January 21, 2015, Mike Mickey and Michael Shepherd of this office met with Michael Weir, ORC, to perform a Compliance Evaluation Inspection of the NPDES wastewater discharge from the Sparks Road Water Treatment Plant (WTP). The treatment system was found to be compliant with the NPDES permit. The inspection findings are detailed below and an inspection checklist is attached for your records. I. Permit The NPDES permit was renewed on August 1, 2014. Permit condition A.(3) requires the submittal of electronic discharge monitoring reports (eDMR) on or before April 1, 2015. H. Self-Monitorine Program The monthly self -monitoring reports (DMRs) were reviewed for the period January 2014 through November 2014. The facility was found to be compliant with all permit effluent limits (see data summary attached). In regards to the permit monitoring requirements, it was noted that all sampling was being performed per the frequencies specified in the permit. III. Flow Measurement The NPDES permit requires continuous flow recording and annual calibration of the flow measuring device. Effluent flow values reported on the DMRs are measured using an ultrasonic meter with parshall flume. The meter was last calibrated by Fortech on July 30, 2014. IV. Sludee Handling and Disposal Solids collected in the settling lagoons are land applied under non -discharge permit No. WQ0028806. The residuals were last removed by EMA Resources in 2010. V. Operations and Maintenance The facility was competently operated and maintained. No problems or concerns were noted. 450 West Hanes Mill Road, Suite 300, Winston-Salem, NC 27105 Phone: 336-776-9800 \ Internet: www.ncwaterguality.or✓; An Equal Opportunity \ Affirmative Action Employer— Made in part by recycled paper Mr. Johnny Lambert Page 2 January 23, 2015 VI. Facility Site Review The treatment system components for the filter backwash and clarifier wastewater consist of the following: two 785,000 gallon settling lagoons operated in parallel, tablet dechlorinator and flow meter. VII. Records/Reports A comparison of the November DMRs with the operator's field measurements and the laboratory data from Statesville Analytical showed that all data was transcribed onto the DMRs correctly. VM. Effluent/ReceivinE Waters The system discharges into a ditch leading to a tributary of the Yadkin River, class "WS-IV" waters in the Yadkin -Pee Dee River Basin. The effluent was clear on the day of inspection. Our office appreciates your efforts to comply with the NPDES permit. Should you have any questions concerning this report, please contact Mike Mickey or me at (336) 771-5000. Sincerely, Sherri V. Knight, PE Assistant Regional Supervisor Water Quality Regional Operations Division of Water Resources cc: Mike Weir (via email: sparksrdwtp@yadtel.net) Central Files WSRO r Sparks Road WTP NPDES Permit No. NCO084212 Self -Monitoring Data Summary January 2014 — November 2014 Parameters Monthly Avg. Permit Limit Monthly Avg. Limit Violations per DMR Daily Maximum Permit Limit Daily Max. Limit Violations per DMR Flow (MGD) - NA - NA TSS (mg/L) 30.0 None 45.0 None pH (S.U.) - NA (6.0-9.0) range None R. Chlorine (ug/L) - NA 17.0* None Turbidity (NTU) - NA - NA Manganese (mg/L) - NA - NA Flouride (mg/L) - NA - NA T. Iron (mg/L) - NA - NA T. Copper (mg/L) - NA - NA T. Zinc (mg/L) - NA - NA T. Phosphorus (mg/L) - NA - NA T. Nitrogen (mg/L) - NA - NA Chronic Toxicity (P/F) monitoring only** NA - NA * TRC values reported below 50 ug/L are considered compliant. * * Chronic Toxicity monitoring is a pass/fail test @ 90% with no limit. Permit: NCO084212 Owner - Facility: Sparks Road WTP Inspection Date: 01/01/2015 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ 0 ❑ application? Is the facility as described in the permit? ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ ❑ ❑ Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? 0 ❑ ❑ ❑ Comment: The NPDES permit was reissued August 1 2014 and recluires that the facility begin submifting DMRs electronically on or berfore April 1 201 . The Sparks Road WTP was found to be compliant will all effluent limits and monitoring_ requirements for the review period January 2014 through November 2014. A review of the November 2014 DMR found that all values were transcribed correctly from the operator records (for PH and total residual chlorine) and from the Statesville Analytical data results (remainder of the permit parameters). It was noted that the chronic toxicity test conducted in February 2014 was reported as a "fail". Currently, the permit does just requires toxicity monitoring with no limit. Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Treatment of the filter backwash and clarifier wastewater consists of the following: *Two 785,000 gallon settlinq lagoons in parallel. *Tablet dechlorinator unit. *Ultrasonic flow meter with parshall flume. Residuals from the lagoons are land applied under non -discharge permit No W00028806 Approximately 270 dry tons were last removed from both lagoons in 2010. De -chlorination Yes No NA NE Type of system ? Tablet Is the feed ratio proportional to chlorine amount (1 to 1)? ❑ ❑ 0 ❑ Is storage appropriate for cylinders? ❑ ❑ M ❑ # Is de -chlorination substance stored away from chlorine containers? ❑ ❑ 0 ❑ Comment: Are the tablets the proper size and type? N ❑ ❑ ❑ Are tablet de -chlorinators operational? M ❑ ❑ ❑ Page# 3 Permit: NCO084212 Inspection Date: 01/01/2015 De -chlorination Number of tubes in use? Owner - Facility: Sparks Road WTP Inspection Type: Compliance Evaluation Comment: The two dechlorinator tubes are located just prior to the flow monitoring structure. Flow Measurement - Effluent # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Yes No NA NE 2 Yes No NA NE ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ M ❑ Comment: Effluent flow is measured using an ultrasonic meter with parshall flume. The meter was last calibrated by Fortech on 7-30-14. The average daily discharge from the Sparks Road WTP for the period 1/14 -11/14 was approximately 1.4 MGD. Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? 0 ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? M ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ M ❑ Comment: The effluent is discharged into a ditch adjacent to the flow monitoring structure. The ditch leads to a tributary of the Yadkin River. class "WS-W waters. This tributary enters the river just downstream of the intake structure. Page# 4 Mickey, Mike From: Mickey, Mike Sent: Wednesday, January 07, 2015 2:27 PM To: Carter, Jenifer Subject: FW: NCG590000 - WTP FYI — Conversion at renewal. It is in the permit under Part 1.A(3). From: Hennessy, John Sent: Wednesday, January 07, 2015 2:17 PM To: Weaver, Charles; Grzyb, Julie Cc: Mickey, Mike Subject: RE: NCG590000 Due to the existing staffing levels and current permitting volume, it was our intention to process these on their original renewal schedule. I hope this answers everyone's questions. Please let me know if you have any questions, or require any additional information. Thanks. From: Weaver, Charles Sent: Wednesday, January 07, 2015 2:01 PM To: Hennessy, John; Grzyb, Julie Cc: Mickey, Mike Subject: FW: NCG590000 I know that we won't require a fee to modify existing NC00 permits to NCG59. However, are we allowing changeovers before a permit is due for renewal? Let me know, and I'll forward the answer to Mike. From: Mickey, Mike Sent: Tuesday, January 06, 2015 4:26 PM To: Weaver, Charles Subject: NCG590000 Charles —I assume existing WTP's that meet the criteria will be moved to the new general permit at renewal. If a facility wants to transfer in mid -permit cycle, can they go ahead and submit Short Form C — WTP without a fee? Will it be processed? Thanks, Mike. Mike.Mickey@NCDENR.gov NC DENR Winston-Salem Regional Office Division of Water Resources — Water Quality Programs 450 W. Hanes Mill Road, Suite 300, Winston-Salem, NC 27105 (336) 776-9697 Please note new address and telephone number. E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. Mickey, Mike From: Mickey, Mike Sent: Tuesday, May 13, 2014 10:53 AM To: Corporon, Joe Subject: RE: Review of Permit DRAFT - for Davie Couty - Sparks Road WTP - NC0084212 Joe — Can you update the facility description on the Supplement Page to include "tablet dechlorination" and "flow measurement by ultrasonic meter and parshall flume"? Everything else looked okay. Thanks, Mike. Mike Mickey Mike.MickevPNCDENR.eov NC Division of Water Resources 585 Waughtown Street Winston-Salem, NC 27107 Phone: (336) 771-4962 FAX: (336) 771-4630 From: Basinger, Corey Sent: Monday, May 12, 2014 3:34 PM To: Mickey, Mike Subject: FW: Review of Permit DRAFT - for Davie Couty - Sparks Road WTP - NC0084212 Please review and comment back to Joe Corporon. THanks. CB W. Corey Basinger Regional Supervisor Water Quality Regional Operations Winston-Salem Regional Office Division of Water Resources Email: corey.basinger@ncdenr.gov Phone: (336) 771-5000 Fax (336) 771-4630 From: Corporon, Joe Sent: Tuesday, May 06, 2014 11:49 AM To: Basinger, Corey; Meadows, Susan; johnny.lambert@co.davie.nc.0 Subject: Review of Permit DRAFT - for Davie Couty - Sparks Road WTP - NC0084212 Please review and comment, as needed. Draft to Public Notice on 07May2014 Respectfully, Joe R. Corporon, L.G. ROC DENR / DWR / NPDES EXPEDITED FACT SHEET - NPDES PERMIT DEVELOPMENT NPDES Permit NCO084212 Joe R. Corporon, L.G., Expedited Permitting and Compliance Unit 25Apr2014 qz s L -. �ari3✓ :Qf+&ti0 -.3 Sparks Road WTP Applicant s Davie County Water System Coi tabt - ' Director: Johnny Lambert Bohnny.lambert@co.davie.nc.us] Applicant Address 298 /East Depot Street, Mocksville 27028 Facility Address 728 Sparks Road, Mocksville 27028 �'�riautt@dFlovy;(Gb) h :; Not limited Type of Waste a Potable WTP / filter backwash (Conventional treatment Technology). Facility Class County Davie Faci[ity Status Renewal Regton4l Office WSRO y. 1Strelrtn v r .., .: .. Recervm stream %Basin `, UT to Yadkin River 3'Y„ C. F 'mi 1 19AI� +.. S re��n l s a Qn ' WS-1V Stream Segment 12-(86.7) braiur a $sin" Yadkin -Pee Dee ,�. River Basin Sumuner,,7Q10 (cfs) St1b ";% ���, 03-07-02 Winter 7Q.10 ila;PPtta� . Yes 30Q2 (cfs) %303(d),]eds No Average,Flow (afs) Sta'ds) D17SE / C17SW 100 % p'Quad' Farmington / Clemmons, NC Facility Summary— This WTP employs conventional treatment technology [coagulation, flocculation, sedimentation, and filtration] to produce potable water at a system -design rate of 3.0 MGD. Previous permit required installation of "continuous recording" by March 1, 2011. Filter -backwash discharge rates vary over time, but reported for the past two years, average 1.241 MGD with a maximum at 2.355 MGD; minimum 0.786 MGD [years 2012-2013; n = 671]. WASTE -WATER Flow History Jan2009 - Mar2014 YEAR n AVE MAX MIN 2009 52 0.158 0.326 0.021 2010 51 0.171 0.326 0.043 2011 290 1.253 2.173 0.075 2012 306 1.481 2.335 0.786 2013 365 1.340 1.996 0.960 2014 thru Mar 90 1.142 1.352 0.855 Fact Sheet Renewal 2014 -- NPDES Permit NCO084212 Page 1 of 1 Summary of Renewal Changes: 1. Withni 270-days the Permittee must to apply for elech-onic submittal of monthly DMRs (eDMRs). 2. Updated facility description [Supplement to Cover Sheet] ; updated Vicinity Map, Lat. / Long; 3. Added parameter codes to effluent table, Section A. (1.); 4. WET testing continued; required of facilities employing conventional h•eahnent technology. 5. Pertnittee will be required to address toxicity with additional study; therefore, included Special Condition [see Section A. (4.)]. Quarterly WET test history over the past permit cycle shows 19 test events (TGP3B); Pass =16; Fail = 3 (in the past year, including the most recent 181762014). 6. The renewal application states that the Permittee does not use alum / aluminum sulfate therefore monitoring for aluminum will be discontinued for renewal. Reasonable Potential Analysis (RPA). DWR conducted an RPA on data for the parameters Al, Mn, Fe, Cu, F, and Zn (see attached). Only Cu, Fe, and Zn show RP; action level parameters, therefore monitoring only is required, no limits [see Section A. (1.)]. Turbidity Data Jan2010-Mar2014 (n = 106): Max =140 ntu; min = 0.5 ntu; ave. = 4.44 ntu Fact Sheet Renewal Apr2014 -- NPDES NC0084212 Page 2 of 2 N.C.Deot. of ENR I MAY 12 2014 I Winston-salem NCDENR Re ionalOffba North Carolina Department of Environment and Natural Resources Division of Water Resources Pat McCrory John E. Skvarla, III Governor Secretary Johnny Lambert, Director Davie County Water System 298 East Depot Street Mocksville, North Carolina 27028 May 7, 2014 Subject: NPDES Permit - DRAFT Review Permit NCO084212 Sparks Road Water Treatment Plant (WTP) 728 Sparks Road, Mocksville Davie County Dear Mr. Lambert: Based on your renewal request for the subject site (received April 23,.2014), the Division of Water Resources (DWR or the Divisi6) hereby transmits a renewal draft for your review and comment. Please review this draft carefully to ensure your understanding of the limits and monitoring conditions, and to correct errors, if any. Concurrent with this notification, the Division will solicit public comment on this draft by publishing a notice in newspapers having circulation in the general Davie County area, as required by the NPDES Program. Please provide your written comments, if any, to DENR / DWR / NPDES Program no later June 10, 2014 (approximately 30 days after receiving this document). We welcome your written comments, but they are not mandatory. Changes for Renewal. The Division updated your permit in accord with current permitting strategies for potable water treatment plants (WTPs) applying conventional WTP treatment technology. We have also updated your facility description and site map, and have added test -method parameter codes for your convenience [see Section A. (1)]. Please note that recent Whole Effluent Toxicity (WET) test failures suggest that this effluent may be harmful to the aquatic environment. Therefore the Division has included a Special Condition that may require additional action [see permit Section A. (4)]. Implementing Electronic Discharge Monitoring Reports (eDMRs). Please be advised that the Division will implement an electronic Discharge Monitoring Report (eDMR) program, in accord with pending 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Location: 512 N. Salisbury St. Raleigh, North Carolina 27604 Phone: 919.807-63001 FAX: 919-807-64921 Customer Service:1-877-623-6748 Internet: www,ncwaterquality.org An Equal Opportunity 1 Affirmative Action Employer requirements by the Environmental Protection Agency (EPA). We have included the details required to implement the eDMR program in this permit [see permit Special Condition A. (2.)]. Proposed federal regulations require electronic submittal of all DMRs and specify that, if North Carolina does not establish a program to receive such submittals, Permittees must then submit eDMRs' directly to EPA. For more information on eDMRs, registering for eDMR submittal, and obtaining an eDMR user account, please visit DWR's webpage: http://-portal.ncdenr.org/web/wq/adminibog/ipu/edmr. For information on EPA's proposed NPDES Electronic Reporting Rule, please visit EPA's website: http://www2.epa. ov/compliance/proposed-npdes-electronic-reporting-rule Following the mandatory 45-day public comment period, the Division will review all pertinent comments, if any, and take appropriate action prior to issuing an NPDES permit final. If you have questions concerning this draft, please e-mail me Ooe.corporon@ncdenr.gov], or call my direct line (919) 807-6394. (ron, L.G., ROC and Expedited Permitting Unit Enclosure: NPDES Permit NCO084212 (DRAFT) hc: WSRO/SWPS Supervisor, Corey Basinger [draft permit, Fact Sheet] NPDES Program Files [draft permit and Fact Sheet] ec: DWR/WSRO, Corey Basinger [draft permit and Fact Sheet] Davie County Water Systems, Johnny Lambert Oohnny.lambert@co.davie.nc.us] [draft and Fact Sheet] ATU Susan Meadows [draft permit and Fact Sheet] 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Location: 512 N. Salisbury -St. Raleigh, North Carolina 27604 Phone: 919-807-63001 FAX: 919-807-64921 Customer Service:1-877-623-6748 Internet: www.ncwaterquality.org An Equal Opportunity 1 Affirmative Action Employer NPDES Permit NCO084212 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER RESOURCES PERMIT TO DISCHARGE WASTEWATER UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) In compliance with the provisions of North Carolina General StatGt�;143-215.1, other lawful standards and regulations promulgated and adopted by the orth-Carolina Environental Management Commission, and the Federal Water Polluji n�nlrm , Act, as amended, the Davie County vc ter System is hereby authorized to di Sparks 7 to receiving waters d� Dee River Basin in ac conditions set forth in This permit shall become ka ater ftorrr'a facility located at the Tr� tei1 nt (WTP) :oad,\ Locksville as ` � f ed tributary to the Yadkin River within the Yadkin -Pee with ftitations, monitoring requirements, and other II,IIIar�hereof. i �tVi e ,i , 2014. This permit and authorization to discharge shall expire at midnight on May 31, 2019. Signed this day , 2014. Thomas A. Reeder, Director Division of Water Resources By Authority of the Environmental Management Commission Permit NCO084425 SUPPLEMENT TO PERMIT COVER SHEET All previous NPDES Permits issued to this facility, whether for operation or discharge are hereby revoked. As of this permit issuance, any previously issued permit bearing this number is no longer effective. Therefore, the exclusive authority to operate and discharge from this facility arises under the permit conditions, requirements, terms, and provisions included herein. Davie County Water System is hereby authorized to: 1. continue to operate wastewater treatment facilities in s , pjp o� b�able water production (3.0 MGD) using WTP conventional treatment technolg yg�coagulatio flocculation, sedimentation, and filtration] generating filter -backwash waste atep(ave. —1.24 N, and waste solids (sludge) at facilities described as; \Q< ,� X\ • influent lagoon (15MG; Ya ~River so ce ter) • four (4) each clarifier -filters • finish -water clear ells • two (2) was der//1 n (eac V8 als • solids land a - I ation . • drain line with nle n o outfall il-izzina-the -Chemicals ➢ pre -caustic ' 0n��CY]. ➢�frric sulfate e (SO 31 ➢ caiis��t i [sodium h droi�l (NaOH)] ➢ chlorin dioxid [ 1 102] ➢ zinc-ortkio ,hosphate [Zn3(PO4)21 ➢ fluoride ( i / located at the Sparks Road Water Treatment Plant (WTP), 728 Sparks Road, Mocksville, Davie County; and 3. discharge from said treatment works via Outfall 001, at the location specified on the attached map, into an unnamed tributary of the Yadkin River [Stream Index 12-(86.7)], a waterbody currently classified WS-IV within Subbasin 03-07-02 of the Yadkin -Pee Dee River Basin. Page 2 of 6 Permit NCO084425 PART I A. (L) EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS During the period beginning on the effective date of this permit and lasting until expiration, the Permittee is authorized to discharge from Outfall 001. Such discharges shall be limited and monitored, and reported I by the Permittee as specified below: EFFLUENT CHARACTERISTICS (PARAMETER CODES) LIMITS MONITORING REQUIREMENTS 1 Monthly Average Daily Maximum Measurement Frequency Sample Type Sample Location Flow 50050 Continuous Recording Effluent Total Suspended Solids (TSS) 00530 30.0 mg/L 45.0 mg/L k\4onth Grab Effluent Total Residual Chlorine (TRC)2 50060 17µg/L2 < 2/Month Grab Effluent Turbidity 3 00076 C / '2Wonth Grab Effluent pH 00400 Nottand 0i d fs 2 \W� th \ Grab Effluent Total Manganese 4 01055 r/ Mont`lk\ Grab Effluent Total Fluoride 00951 Monthly Grab Effluent Total Iron 4 01045 Quarterly Grab Effluent Total Copper 4 OkO42� ` �� ` Quarterly Grab Effluent Total Zinc 110092 \ \ �„\ �� Quarterly Grab Effluent Total Phosphorous (TP) 4 < � C0665 ��, Y Quarterly Grab Effluent Total Nitrogen (TN) 4 �\-0610 J Quarterly Grab Effluent WET -Testing �B tee. Quarterly Grab Effluent Footnotes: \ j 1. No later than , 270 a � fro t permit effective date, begin submitting electronic discharge Monitoring Reports (BD14Rs) using R ' 's eLQMR application system, or apply for a waiver [See Section A. (3.)]. 2. Total Residual Chlorine) - TI1 D'�ision shall deem compliant all effluent TRC values reported below 50µg/L. However, the Permittee, shall t�cord and submit all values detected by North Carolina -certified test methods (including field certified)ven if these values are detected below 50µg/L. 3. Turbidity - Discharge from this`if cility shall not cause receiving -stream turbidity to exceed 50 NTU. If natural background turbidity exceeds 50 NTU, this discharge shall not increase receiving stream turbidity. 4. Parameter to be sampled concurrently with WET -test sampling. 5. Whole Effluent Toxicity (WET) testing conducted as Chronic [TGP3B] using Ceriodaphnia dubia, 7-day pass/fail @ 90% effluent concentration, during the months of February, May, August and November [see Section A. (2.)]. Condition.— , - All samples collected shall accurately represent the effluent discharge event. The Permittee shall discharge no floating solids or foam. This permit includes a WET -test compliance Special Condition [see Section A. (4.)]. Page 3 of 6 Permit NC0084425 A. (2.) CHRONIC TOXICITY PASS/FAIL MONITORING (QUARTERLY) The Permittee shall conduct quarterly chronic toxicity tests using test procedures outlined in the "North Carolina Ceriodaphnia Chronic Effluent Bioassay Procedure," Revised December 2010, or subsequent versions. The effluent concentration defined as treatment two in the procedure document is 90%. The testing shall be performed as a Ceriodaphnia dubia 7-day pass/fail test. The tests will be performed during the months of February, May, August and November. These months signify the first month of each three-month toxicity -testing quarter assigned to the facility. Effluent sampling for this testing must be obtained during representative effluent discharge and shall be performed at the NPDES permitted final effluent discharge below all treatment processes. All toxicity testing results required as part of this permit condition will be entered on the Effluent Discharge Monitoring Form (MR-1) for the month in which it was performed, using the parameter code TGP3B. Additionally, DWR Form AT-1 (original) is to be sent to the following adfir�ss: Attention: North Carolina Division of Environmental Sciences 1621 Mail Service nt r Raleigh, N.C. 2, 99,16, Completed Aquatic Toxicity Test Forms shall be filed wit: 30 days after the end of the reporting period for�hich the Test data shall be complete and accurate and inc�u performed in association with the toxici tests, a the effluent toxicity sample must b�r lstd and waste stream. 1// / Section no later than Uphysical measurements data. Total residual chlorine of gloved for disinfection of the Should there be no disch e of Flo from flieifacility c�uri�g a month in which toxicity monitoring is required, the Permitpe�l cc letSlVe igfb;n� aur4o�d.5d at the top of the aquatic toxicity (AT) test form indicating the fa rhtyrrnain p� n inVoi r, pipe�nlii' bbe�county, and the month/year of the report with the notation of "Nolow4\in the co�tit a4e of the form: The report shall be submitted to the Environmental Sciences Section at the address cited \dbov7\ Should the Permittee fair o) onitor dliri g a month in which toxicity monitoring is required, then monthly monitoring will begin imm� tely. d- po submission of a valid test, this monthly test requirement will revert to quarterly in the montl}s sKecified above. Should any test data from this monitoring requirement or tests performed by the North Carolina Division of Water Resources indicate potential impacts to the receiving stream, this permit may be re -opened and modified to include alternate monitoring requirements or limits. If the Permittee monitors any pollutant more frequently than required by this permit, the results of such monitoring shall be included in the calculation & reporting of the data submitted on the DMR & all AT Forms submitted. NOTE: Failure to achieve test conditions as specified in the cited document, such as minimum control organism survival, minimum control organism reproduction, and appropriate environmental controls, shall constitute an invalid. test and will require immediate follow-up testing to be completed no later than the last day of the month following the month of the initial monitoring. Page 4 of 6 Permit NCO084425 A. (3.) ELECTRONIC REPORTING - DISCHARGE MONITORING REPORTS Proposed federal regulations require electronic submittal of all discharge monitoring reports (DMRs) and specify that, if a state does not establish a system to receive such submittals, then Permittees must submit DMRs electronically to the Environmental Protection Agency (EPA). The Division anticipates that these regulations will be adopted and will begin implementing in 2013. NOTE: This special condition supplements or supersedes the following sections within Part II of this permit (Standard Conditions for NPDES Permits): 1. • Section B. (11.) Signatory Requirements • Section D. (2.) • Section D. (6.) • Section E. (5.) Reporting Records Retention Monitoring Reports Beginning no later than Permittee shall begin reporting discharge r Electronic Discharge Monitoring Report ( , 270 days Monitoring results obtained during the previous i'no%h(s) and submitted electronically using eD1V�� The eD �5 enter monitoring data and submit DMR elect onicall us the state's eDMR application is compli CPA's z Regulation (CROMERR), Pe�itees will ,e eq��i �I the state electronically usitrtg e printing, signing, ands mn Ni to the following address: NC DENRInfo ti ATTENTIO Central1)ms 1617 Mail Servi&Center ive date of this permit, the y using the NC DWR's be summarized for each month 6 allows pe 'yrtatd facilities to the internet. l such time that Media Electronic Reporting t all discharge monitoring data to plete the eDMR submission by py of the computer printed eDMR Raleigh, North C'aro�l'na 27699 1' 17 U If a Permittee is unabl' t us th eDMR system due to a demonstrated hardship or due to the facility being physically locaat d in an area where less than 10 percent of the households have broadband access, then a t�mporary waiver from the NPDES electronic reporting requirements may be granted and discharge monitoring data may be submitted on paper DMR forms (MR 1, 1. 1, 2, 3) or alternative forms approved by the Director. Duplicate signed copies shall be submitted to the mailing address above. Requests for temporary waivers from the NPDES electronic reporting requirements must be submitted in writing to the Division for written approval at least sixty (60) days prior to the date the facility would be required under this permit to begin using eDMR. Temporary waivers shall be valid for twelve (12) months and shall thereupon expire. At such time, DMRs shall be submitted electronically to the Division unless the Permittee re -applies for and is granted a new temporary waiver by the Division. Page 5 of 6 Permit NCO084425 Information on eDMR and application for a temporary waiver from the NPDES electronic reporting requirements is found on the following web page: http://-Portal.ncdenr.or web/wq/adminibog/it)u/edmr Regardless of the submission method, the first DMR is due on the last day of the month following the issuance of the permit or in the case of a new facility, on the last day of the month following the commencement of discharge. 2. Signatory Requirements [Supplements Part II, Section B. (11.) (b) and supersedes Section B. (11.) All eDMRs submitted to the permit issuing authority shall be signed by a person described in Part II, Section B. (11.)(a) or by a duly authorized representative of that person as described in Part II, Section B. (11.)(b). A person, and not a position, must be delegated signatory authority for eDMR reporting purposes. 1/\ For eDMR submissions, the person signing and submitti gt - ]] R must obtain an eDMR user account and login credentials to access the eDMR sy� For r or• information on North Carolina's eDMR system, registering for eDMR /an�otaimng an R user account, please visit the following web page: C Certification. Any person submitting aii make the following certificati n-[4Q CFR CERTIFICATION WILL BE AeGE�TEI U certify, under penalty of direction or sup rvision`n properly ga fftr qnd eva ua persons who�rna`nage they information, the�inormatio and complete. I arV �cr�ware t including the possibitity of 3. Records Reten ["sing the state's eDMR system shall OTaER STATEMENTS OF `h� docuh ei, and all attachments were prepared under my ,e�rtkE a s\ tem designed to assure that qualified personnel P ati n ub tted. Based on my inquiry of the person or hose persons directly, responsible for gathering the t , to the best of my knowledge and belief, true, accurate, r\ejsignificant penalties for submitting false information, imprisonment for knowing violations. " The Permittee shall retain records of all Discharge Monitoring Reports, including eDMR submissions. These records or copies shall be maintained for a period of at least 3 years from the date of the report. This period may be extended by request of the Director at any time [40 CFR 122.41]. A. (4.) PERMIT RE -OPENER - WHOLE EFFLUENT TOXICITY MONITORING This facility's history of Whole Effluent Toxicity (WET) monitoring indicates that discharge to surface waters may be toxic to the aquatic environment. The Division of Water Resources therefore may reopen this permit, or request by letter that the Permittee take further action. This action may include additional metals testing, a Toxicity Identification Evaluation / Toxicity Reduction Evaluation (TIE/TRE), additional assessment of discharge alternatives, and/or review of waste treatment alternatives. Page 6 of 6 s 1455 786 . all, 511 --If Approx. imate,Property Botrndaiy: Davie County Water System Sparks Road WTP, Mocksville Flows: Potable 3.0 MGD; WW 1.350 MGD USGS Ouads: Farmington/Clemmons State Grids: C16SE / C17SW Receiving Stream: UT to the Yadkin River Stream Class: WS-IV Stream Segment: 12-(86.7) HUC: 03040101 DrainageBasin: Yadkin— Pee Dee Basin Sub -Basin: 03-07-02 Facility • Location not to scale NPDES Permit NCO084212 North Davie County Permit: WO0028806 SOC: County: Davie Region: Winston-Salem Compliance Inspection Report Effective: 11/19/10 Expiration: 04/30/14 Owner: Davie County Public Utilities Effective: Expiration: Facility Sparks Road WTP Residuals Distribution Program Contact Person: Beth Dirks Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Title: County Manager Certification Inspection Date: 01/30/2014 Entry Time: 09:30 AM Exit Time: 10:30 AM Primary Inspector: Michael M Mickey Secondary Inspector(s): Phone: 336-751-5513 Phone: Phone: 336-771-4962 Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Distribution of Residual Solids (503 Exempt) Facility Status: ■ Compliant ❑ Not Compliant Question Areas: 0 Miscellaneous Questions E Record Keeping (See attachment summary) Page: 1 Permit: W00028806 Owner - Facility: Davie County Public Utilities Inspection Date: 01/30/2014 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: Type Yes No NA NE Distribution and Marketing ❑ Land Application ■ Record Keeping Yes No NA NE Is GW monitoring being conducted, if required? ❑ ❑ ❑ ■ Are GW samples from all MWs sampled for all required parameters? ❑ ❑ ❑ ■ Are there any GW quality violations? ❑ ❑ ❑ ■ Is GW-59A certification form completed for facility? ❑ ❑ ❑ ■ Is a copy of current permit on -site? ■ ❑ ❑ ❑ Are current metals and nutrient analysis available? ❑ ❑ ❑ ■ Are nutrient and metal loading calculating most limiting parameters? ❑ ❑ ❑ ■ a. TCLP analysis? ❑ ❑ ❑ ■ b. SSFA (Standard Soil Fertility Analysis)? ❑ ❑ ❑ ■ Are PAN balances being maintained? ❑ ❑ ❑ ■ Are PAN balances within permit limits? ❑ ❑ ❑ ■ Has land application equipment been calibrated? ❑ ❑ ❑ ■ Are there pH records for alkaline stabilization? ❑ ❑ ❑ ■ Are there pH records for the land application site? ❑ ❑ ❑ ■ Are nutrient/crop removal practices in place? ❑ ❑ ❑ ■ Do lab sheets support data reported on Residual Analysis Summary? ❑ ❑ ❑ ■ Are hauling records available? ■ ❑ ❑ ❑ Are hauling records maintained and up-to-date? ❑ ❑ ❑ ■ # Has permittee been free of public complaints in last 12 months? ❑ ❑ ❑ ■ Has application occurred during Seasonal Restriction window? ❑ ❑ ❑ ■ Comment: Reviewed land application records during NPDES inspection (NC0084212). The Sparks Road WTP last applied residuals in 2005 (155 dry tons from 1 of 2 settling lagoons) and in 2010 (270 dry tons from both lagoons). EMA Resources uses a sludge jugde from a john boat to determine when solids removal is necessary. Land application in 2014 is not expected. Page: 2 NCD NR North Carolina Department of Environment and Natural Resources Division of Water Resources Pat McCrory Governor Attn: Johnny Lambert Director of Public Utilities 298 E Depot St. Mocksville, NC 27028 Dear Mr. Lambert: April 24, 2014 APR 2 5 2014 John E. Skvarla, III Secretary RECEIVED N.C.Dept. of ENR APR 2 8 2014 Winston-Salem Regional Office Subject: Acknowledgement of Permit Renewal Permit NCO084212 Davie County The NPDES Unit received your permit renewal application on April 24, 2014. A member of the NPDES Unit will review your application. They will contact you if additional information is required to complete your permit renewal. You should expect to receive a draft permit approximately 30-45 days before your existing permit expires. If you have any additional questions concerning renewal of the subject permit, please contact Joe Corporon (919) 807-6394. Sincerely, KA@IXJ Wren Thedford Wastewater Branch cc: Central Files Raleigh Regional Office NPDES Unit 1617 Mail Service Center, Ralegh, North Carolina 27699-1617 Location: 512 N. Salisbury St. Raleigh, North Carolina 27604 Phone: 919-807-63001 Fax: 919-807-64921Customer Service:1-877-623-6748 Internet:: www.ncwater.org An Equal OpportunitylAfrirmative Action Employer NPDES PERMIT APPLICATION - SHORT FORM C - WTP For discharges associated with water treatment plants Mail the complete application to: N. C. Department of Environment and Natural Resources Division of Water Quality / NPDES Unit 1617 Mail Service Center, Raleigh, NC 27699-1617 NPDES Permit Number NC0084212 If you are completing this form in computer use the TAB keg or the up - down arrows to move from one field to the next. To check the boxes, click your mouse on top of the box. Otherwise, please print or type. 1. Contact Information: Owner Name Davie County Water System Facility Name Sparks Road WTP IVR/DWR Mailing Address 298 East Depot St. APH 4 2014 City Mocksville State / Zip Code NC, 27028 Water Resources Permitting ce ction Telephone Number (336) 753-6090 Fax Number (336) 751-5885 e-mail Address Johnny.lambert@co.davie.nc.us 2. Location of facility producing discharge: Check here if same as above ❑ Street Address or State Road 728 Sparks Road City Mocksville State / Zip Code NC, 27028 County Davie 3. Operator Information: Name of the firm, consultant or other entity that operates the facility. (Note that this is not referring to the Operator in Responsible Charge or ORC) Name Davie County Public Utilities Mailing Address 298 East Depot St. City Mocksville State / Zip Code NC, 27028 Telephone Number (336) 753-6090 Fax Number (336) 751-5888 4. Ownership Status: Page 1 of 4 Version 5/2012 Davie County Public Utilities 298 East Depot Street Mocksville, NC 27028 4/9/14 Mr. Wren Thedford NCDENR/DWR/NPDES Unit 1617 Mail Service Center Raleigh, NC 27699-1617 Re: Renewal of NPDES Permit NCO084212 Sparks Road WTP Wastewater Discharge Dear Wren: Please renew the above reverenced NPDES permit for the Davie County Sparks Road WTP wastewater discharge. The only changes to facility processes have involved instrumentation and control enhancements including the 2010 addition of a flow monitoring station at the wastewater dechlorination and discharge point incorporating SCADA integration and flow tracking. Attached are one signed original and two copies of each of the following: 1. Cover letter; 2. Application Form: 3. Sludge Management Narrative 4. Facility Location Exhibit; 5. Facility Process Schematic. Th you, Aki*c Johnny Lambert, Director Attachments ' � s Federal ❑ NPDES PERMIT APPLICATION - SHORT FORM C - WTP For discharges associated with water treatment plants State ❑ Private ❑ Public X 5. Type of treatment plant: X Conventional (Includes coagulation, flocculation, and sedimentation, usually followed by filtration and disinfection) ❑ Ion Exchange (Sodium Cycle Cationic ion exchange) ❑ Queen Sand Filter (No sodium recharge) ❑ Membrane Technology (RO, nanofiltration) Check here if the treatment process also uses a water softener ❑ 6. Description of source water(s) (i.e. groundwater, surface water) Yadkin River Surface Water 7. Describe the treatment process(es) for the raw water: Presedimentation, Coagulation (ferric sulfate), Clarification, Filtration, Disinfection (chlorine gas) and Discharge to the Clearwell. S. Describe the wastewater and the treatment process(es) for wastewater generated by the facility: The wastewaters are clarifier and filter backwash conveyed to two treatment lagoons of 785,000 gallons each which are decanted through dechlorination (sodium sulfite tablets) and now measurement to a ditch tributary to the Yadkin river. 4. Number of separate discharge points: 1 Outfall Identification number(s) 001 10. Frequency of discharge: Continuous X Intermittent ❑ If intermittent: Days per week discharge occurs: Duration: 11. Plant design potable flowrate 3 MGD Backwash or reject flow .264 MGD 1.2. Name of receiving stream(s) (Provide a map showing the exact location of each outfall, including latitude and longitude): Unnamed tributary to Yadkin River. See attached exhibit. Page 2 of 4 Version 5/2012 NPDES PERMIT APPLICATION - SHORT FORM C - WTP For discharges associated with water treatment plants 13. Please list all water treatment additives, including cleaning chemicals or disinfection treatments, that have the potential to be discharged. Alum / aluminum sulfate Yes No X Iron sulfate / ferrous sulfate Yes X No Fluoride Yes X No Ammonia nitrogen / Chloramines Yes No X Zinc -orthophosphate or sweetwater CP1236 Yes X No List any other additives below: Activated Carbon Sodium Sulfite for wastewater dechlorination 14. Is this facility located on Indian country? (check one) Yes ❑ No X 15. Additional Information: > Provide a schematic of flow through the facility, include now volumes at all paints in the water treatment process. The plan should show the point[s] of addition for chemicals and all discharges routed to an outfall [including stormwater]. > Solids Handling Plan 16. NEW Applicants Information needed in addition to items 1-I5: > New applicants must contact a permit coordinator with the NCDENR Customer Service Center.. Johnny Was the Customer Service Center contacted? ❑ Yes ❑ No > Analyses of source water collected > Engineering Alternative Analysis > Discharges from Ion Exchange and Reverse Osmosis plants shall be evaluated using a water quality model. 17. Applicant Certification I certify that I am familiar with the information contained in the application and that to the best of my knowledge and belief such information is true, complete, and accurate. Johnn Lambert Utilities Director Pd 77nam of Person Signing Title r' A . y- 9 - 20�� Date Version 5/2012 Page 3of4 INFLUENT FROM YADKIN RIVER --------------------------- 15 MG i , , , , QHEMICAL ADDITION I PRE -CAUSTIC CARBON -� FERRIC SULFATE, CAUSTIC , CHEMICAL ADDITION CHLORINE, CAUSTIC, PHOSPHATE, FLUORIDE ---� I I WTP—SPARKS14 FLW GREY ENGINEERING, INC. Civil Design and Surveying P.O. Box 9 Mockeville, N.C. 27028 greyengineering.com (336)751-2110 DRAWN BY: G. BULLARD I PROD. NO.: 202.029.GE DESIGN BY: G. BULLARD DATE: 4/09/14 FINISHED WATER CLEARWELL 1 MG DAVIE CHEMICAL ADDITION FLOW SODIUM SULFITE MEASUREMENT ` EFFLUENT TRIBUTARY TO YADKIN RIVER WASTEWATER LAGOONS 785,000 GALS EACH W EFFLUENT — — — FINISHED WATER -------- INFLUENT —• --- SLUDGE — — — WASTING/SCUM COUNTY SPARKS WTP PROCESS SCHEMATIC EXHIBIT 3.0 MGD CAPACITY I OF 1 jjN "y 'r ,ig ��� Ma�_�' lid-- IS 4. . Davie County Public Utilities 298 East Depot Street Mocksville, NC 27028 4/9/ 14 Mr. Wren Thedford NCDENR/DWR/NPDES Unit 1617 Mail Service Center Raleigh, NC 27699-1617 Re: Renewal of NPDES Permit NCO084212 Sparks Road WTP Wastewater Discharge Dear Wren: RECEIVED N.C.Dept. of ENR APR 2 Winston-Salem Regional Offioy; Plea;>e renew the above reverenced NPDES permit for the Davie County Sparks Road WTP wastewater discharge. The only changes to facility processes have involved instrumentation and control enhancements including the 2010 addition of a slow monitoring station at the wastewater dechlorination and discharge point incorporating SCADA integration and flow tracking. Attached are one signed original and two copies of each of the following: 1 Cover letter; 2. Application Form; 3. Sludge Management Narrative 4. Facility Location Exhibit; 5. Facility Process Schematic. Thank you, � 'Jult-, Johnny Lambert, Director Attaciments RECEIVED/DENR/DWR APR - 9 2014 Water Resources Permitting Section NPDES PERMIT APPLICATION - SHORT FORM C - WTP For discharges associated with water treatment plants Mail the complete application to: N. C. Department of Environment and Natural Resources Division of Water Quality / NPDES Unit 1617 Mail Service Center, Raleigh, NC 27699-1617 NPDES Permit Number INCO084212 If you are completing this form in computer use the TAB key or the up - down arrows to move from one field to the next. To check the boxes, click your mouse on top of the box. Otherwise, please print or type. 1. Contact Information: Owner Name; Facility Narne Mailing Add:-ess City State / Zip Code Telephone Number Fax Number e-mail Address Davie County Water System Sparks Road WTP 298 East Depot St. Mocksville NC, 27028 (336) 753-6090 (336) 751-5885 Johnny. lambert@co.davie.nc.us 2. Locatio:n of facility producing discharge: Check here if same as above ❑ Street Address or State Road City State / Zip Code County 728 Sparks Road Mocksville NC, 27028 Davie 3. Operator Information: Name of the.firm, consultant or other entity that operates the facility. (Note that this is not referring to the Operator in Responsible Charge or ORC) Name Davie County Public Utilities Mailing Address 298 East Depot St. City Mocksville State / Zip Code NC, 27028 Telephone Number (336) 753-6090 Fax Number (336) 751-5888 4. Ownership Status: Page 1 of 4 Version 5/2012 Federal [] NPDES PERMIT APPLICATION - SHORT FORM C - WTP For discharges associated with water treatment plants State ❑ Private ❑ Public X S. Type of treatment plant: X Conventional (Includes coagulation, flocculation, and sedimentation, usually followed by f filtration and disinfection) ❑ Ian Exchange (Sodium Cycle Cationic ion exchange) ❑ Breen Sand Filter (No sodium recharge) ❑ lliembrane Technology (RO, nanofiltration) Check here if the treatment process also uses a water softener ❑ 6. Description of source water(s) (i.e. groundwater, surface water) Yadkin. River Surface Water 7. Describe the treatment process(es) for the raw water: Presed1mentation, Coagulation (ferric sulfate), Clarification, Filtration, Disinfection (chloi,-ine gas) and Discharge to the Clearwell. S. Describe the wastewater and the treatment process(es) for wastewater generated by the facilit�r• The wastewaters are clarifier and filter backwash conveyed to two treatment lagoons of 785,000 gallons each which are decanted through dechlorination (sodium sulfite tablets) and flow measurement to a ditch tributary to the Yadkin river. 9. Number of separate discharge points: 1 Outfall Identification number(s) 001 10. Frequency of discharge: If intermittent: Days per week discharge occurs_ Continuous X Intermittent ❑ 11. Plant design potable flowrate 3 MGD Backwash or reject flow .264 MGD Duration: 12. Name of receiving stream(s) (Provide a map showing the exact location of each outfall, including latitude and longitude): Unnamed tributary to Yadkin River. See attached exhibit. Page 2 of 4 Version 5/2012 NPDES PERMIT APPLICATION - SHORT FORM C - WTP For discharges associated with water treatment plants 13. Please! list all water treatment additives, including cleaning chemicals or disinfection treatments, that have the potential to be discharged. Alum / aluminum sulfate Yes No X Iron s alfate / ferrous sulfate Yes X No Fluoride Yes X No Ammonia nitrogen / Chloramines Yes No X Zinc -orthophosphate or sweetwater CP1236 Yes X No List any other additives below: Activated Carbon Sodium Sulfite for wastewater dechlorination 14. Is this facility located on Indian country? (check one) Yes ❑ No X 15. Additional Information: ➢ Provide a schematic of flow through the facility, include flow volumes at all points in tAe water treatment process. The plan should show the point[s] of addition for chemicals and all discharges routed to an outfall [including stormwater]. ➢ Solids Handling Plan 16. NEW Applicants Information needed in addition to items 1-15: ➢ New applicants must contact a permit coordinator with the NCDENR Customer Service Center. Johnny Was the Customer Service Center contacted? ❑ Yes ❑ No ➢ Analyses of source water collected ➢ Engineering Alternative Analysis ➢ Discharges from Ion Exchange and Reverse Osmosis plants shall be evaluated using a water quality model. 17. Applicant Certification I certify that I am familiar with the information contained in the application and that to the best of my Imowledge and belief such information is true, complete, and accurate. Johnny Lam )ert Utilities Director Pri d name f Person Signing Title Ly 9 Date Page 3 of 4 Version 5/2012 NPDES PERMIT APPLICATION - SHORT FORM C - WTP For discharges associated with water treatment plants North Carolina General Statute 143-215.6 (b)(2) provides that: Any person who knowingly makes any false statement representation, or certification in any application, record, report, plan, or other document files or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, shall be guilty of a misdemeanor punishable by a fine not to exceed $25,000, or by imprisonment not to exceed six months, or by both. (18 U.S.C. Section 1001 provides a punishment by a fine of not more than $25,000 or imprisonment not more than 5 years, or both, for a similar offense.) Page 4 of 4 Version 5/2012 Davie County Public Utilities Sparks Road Water Treatment Plant Sludge Handling Plan The Sparks Road WTP has two parallel 785,000-gallon filter backwash lagoons. The lagoons Provide long-term storage of sludge developed during clarifier flushing and filter backwash operation sl atdge is added to the lagoons the s. As chemical solids are settled by gravity. Tla.e supernatant is discharged through the overflow -supernatant pipe to a m, im made ditch that flows to an unnamed tributary of the Yadkin River. Sludge depth is monitored in each lagoon and lagoons are designed to laiiit up to 10 years at the expected plant sludge disposal rate before solids ha+re to be removed. Once lagoons are classified as full, sludge in the lal loons is dredged and land applied on neighboring farm fields. prior to dri 4ging a land application permit is acquired and the sludge is analyzed to as:iure it is safe to apply. The sludge removal is contracted out to a spii,cialized private company to assure that all state and federal laws would be followed though out the sludge removal process. In summary the sludge handling at this facility happens only once evEr 10 years and is contracted out for land application. TERMINAL RESERVOIR INFLUENT FROM YADKIN RIVER -------------------------zl► 15 MG CHEMICAL ADDITION SODIUM FLOW SULFITE MEASUREMENT I I i 1 I 1 EFFLUENT ' I TRIBUTARY TO YADKIN RIVER CHEMICAL ADDITION WASTEWATER PRE —CAUSTIC CARBON LAGOONS FERRIC SULFATE, CAUSTIC 785,000 GALS EACH t NEPTUNE-TRIDENT CLARIFIER -FILTERS -�- -�— - --� W CHEMICAL ADDITION SLUDGE LUDGE CHLORINE, CAUSTIC, I TO PHOSPHATE, FLUORIDE --� DI TRIE3 TI N SYSTEM T WTP—SPARKS14 FLW GREY HIGH SERVICE PUMPS ENGINEERING, INC Civil Design and Surveying P.O. Box 9 Moc:ksville, N.C. 27028 Breyengineering.com (336)751-2110 ENaKQ WATER CLEARWELL 1 MG LEGEND EFFLUENT — — — FINISHED WATER -------- -- INFLUENT — — SLUDGE WASTING/SCUM DAVI E COUNTY SPARKS WTP PROCESS SCHEMATIC EXHIBIT 3.0 MGD CAPACITY 1 OF 1 DRAWN BY: G. BULLARD PROJ. NO.: 202.029.GE DESIGN BY: G. BULLARD I DATE: 4/09/14 NCDE R North Carolina Department of Environment and Natural Resources Division of Water Resources Water Quality Regional Operations Section Pat McCrory Thomas A. Reeder John E. Skvarla, III Governor Director Secretary January 31, 2014 Mr. Johnny Lambert Public Works Director County of Davie 298 E. Depot Street, Suite 200 Mocksville, NC 27028 SUBJECT: Compliance Evaluation Inspection Sparks Road WTP Discharge NPDES Permit No. NCO084212 Davie County Dear Mr. Lambert: On January 30, 2014, Mike Mickey of this office met with Michael Weir, ORC, to perform a Compliance Evaluation Inspection of the NPDES wastewater discharge from the Sparks Road Water Treatment Plant (WTP). The treatment system was found tobe in consistent compliance with the effluent limits and monitoring requirements of the NPDES permit. The inspection findings are detailed below and an inspection checklist is attached for your records. I. Permit The NPDES permit expires on May 31, 2014. Per Part II.B(10) of the permit, a renewal request should have been submitted to the Division at least 180 days prior to expiration. To date, a renewal request has not been received. The application should be submitted to Raleigh on or before February 14, 2014. H. Self -Monitoring Program The monthly self -monitoring reports (DMRs) were reviewed for the period January 2013 through December 2013. The facility was found to be compliant with all permit effluent limits (see data summary attached), except for one daily maximum pH violation that occurred in May 2013. This violation was previously addressed in a Notice of Deficiency letter from this office. In regards to the permit monitoring requirements, it was noted that all sampling was being performed per the frequencies specified in the permit. The review did note that the effluent failed the chronic toxicity test conducted in February 2013. It is our understanding that excessive chlorine was the cause of the test failure. At present, the toxicity requirement in the permit is monitoring only with no effluent limitation. III. Flow Measurement The NPDES permit requires continuous flow recording and annual calibration of the flow measuring device. The daily effluent flow values reported on the DMRs are measured using an ultrasonic meter with parshall flume. The meter was calibrated by Fortech on June 27, 2013. North Carolina Division of Water Resources, Winston-Salem Regional Office Location: 585 Waughtown St Winston-Salem, North Carolina 27107 Phone: 336-771-50001 FAX: 336-771-46301 Customer Service: 1-877-623-6748 Internet: www.ncwaterquality.org NorthCarolina An Equal Opportunity 1 Affirmative Action Employer W Johnny Lambert Page 2 January 31, 2014 IV., Sludge Handling and Disposal Solids collected in the settling lagoons are land applied under non -discharge permit No. WQ0028806. The residuals were last removed by EMA Resources in 2005 and 2010. V. Operations and Maintenance The facility was competently operated and maintained. No problems or concerns were noted. VI. Facility Site Review The treatment components for the filter backwash and clarifier wastewater consist of the following: two 785,000 gallon settling lagoons operated in parallel, two tablet dechlorinator tubes and an ultrasonic flow meter with parshall flume. VH. Records/Reports A comparison of the November and December DMRs with the laboratory data from Statesville Analytical showed that all data was transcribed onto the DMRs correctly, except for the December 17t` samples that were accidently entered on the line for December 16t'. It was noted that the units of measurement (mg/L) for aluminum, manganese, fluoride, zinc, copper, total nitrogen and total phosphorus were not being listed on the DMR. Please include the unit of measurement for these parameters on the form. VHI. EftluentlReceiving Waters The system discharges into a tributary of the Yadkin River, class "WS-IV" waters in the Yadkin -Pee Dee River Basin. The effluent was clear on the day of inspection. Our office appreciates your efforts to comply with the NPDES permit. Should you have any questions concerning this report, please contact Mike Mickey or me at (336) 771-5000. Sincerely, /0'%. Sherri V. Knight, PE Assistant Regional Supervisor Water Quality Regional Operations Division of Water Resources cc: Mike Weir (via email: sparksrdwtp@yadtel.net) Central Files WSRO Sparks Road WTP NPDES Permit No. NCO084212 Self -Monitoring Data Summary January 2013 — December 2013 Parameters Monthly Avg. Permit Limit Monthly Avg. Limit Violations per DMR Daily Maximum Permit Limit Daily Max. Limit Violations per DMR Flow (MGD)* - NA - NA TSS (mg/L) 30.0 None 45.0 None pH (S.U.) - NA (6.0-9.0) range 9.17 S.U. on 5/21/13 R. Chlorine (ug/L) - NA 17.0** None Turbidity (NTU) - NA - NA Aluminum (mg/L) - NA - NA Manganese (mg/L) - NA - NA Flouride (mg/L) - NA - NA T. Zinc (mg/L) - NA - NA T. Copper (mg/L) - NA - NA T. Iron (mg/L) - NA - NA T. Phosphorus (mg/L) - NA - NA T. Nitrogen (mg/L) - NA - NA Chronic Toxicity (P/F) I monitoring only*** NA - NA * The continuous flow monitoring requirement became effective March 1, 2011. * * TRC values reported below 50 ug/L are considered compliant. * * * Chronic Toxicity monitoring is a pass/fail test @ 90% with no limit. Permit: NCO084212 Inspection Date: 01/30/2014 Owner - Facility: Sparks Road WTP Inspection Type: Compliance Evaluation Permit (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Comment: A review of the monthly self -monitoring reports for the period January 2013 through December 2013 found that all monitoring was performed per the frequencies specified in the permit. In addition, the Sparks Road WTP was found to be compliant with the effluent limits of the NPDES permit, except for one daily maximum pH exceedence that occurred on May 21, 2013. (the high pH was caused by excessive algae in the lagoon. Treatment with copper sulfate cured the problem). The permit expires on May 31, 2014. Per Part II.B(10) of the permit, a renewal request should have been submitted to the Division at least 180 days prior to expiration, or before November 30, 2013. To date, a renewal request has yet to be submitted by Davie County. It is our understanding that John Grey is currently working on the paperwork. Operations & Maintenance Is the plant generally clean with acceptable housekeeping? Yes No NA NE ❑ ■ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ Yes Nn NA NF ■ ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge ❑ ❑ ■ _ ❑ Judge, and other that are applicable? Comment: The treatment components for the filter backwash and clarifier wastewater consist of the following: " two 785,000 gallon settling lagoons operated in parallel. " tablet dechlorinator. * ultrasonic flow meter with parshall flume. Solids were last removed from the settling lagoons in 2005 (155 dry tons from one lagoon) and again in 2010 (270 dry tons from both lagoons). A boat and sludge judge is used to determine when wasting is necessary. The residuals are land applied under non -discharge permit No. WQ0028806. Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? ■ ❑ ❑ ❑ Is all required information readily available, complete and current? ■ ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? ■ ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? ■ ❑ ❑ ❑ Page # 3 Permit: NCO084212 Inspection Date: 01/30/2014 Owner - Facility: Sparks Road WTP Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE Is the chain -of -custody complete? ■ ❑ ❑ ❑ Dates, times and location of sampling ■ Name of individual performing the sampling ■ Results of analysis and calibration ■ Dates of analysis ■ Name of person performing analyses ■ Transported COCs ■ Are DMRs complete: do they include all permit parameters? ■ ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ ■ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? ❑ ❑ ■ ❑ Is the ORC visitation log available and current? ■ ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? ■ ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility classification? ■ ❑ ❑ ❑ Is a copy of the current NPDES permit available on site? ■ ❑ ❑ ❑ Facility has copy of previous year's Annual Report on file for review? ❑ ❑ ■ ❑ Comment: A comparison of the November and December DMRs with the laboratory data from Statesville Analytical (they perform analysis for all parameters except pH and total residual chlorine) showed that all parameters were accurately transcribed onto the DMR. It was noted that the samples collected on December 17th were accidently entered on the line for December 16th. Additionally, it was noted that the units of measurement (mg/L) need to be listed on the DMR for aluminum, manganese, fluoride, zinc, copper, total nitrogen and total phosphorus. The chronic toxicity test performed in February 2013 failed. It is our understanding that this failure was due to the presence of excessive chlorine in the effluent. It should be noted that the toxicity requirement in the permit is for monitoring only with no effluent limit. De -chlorination Yes No NA NE Type of system ? Tablet Is the feed ratio proportional to chlorine amount (1 to 1)? ❑ ❑ ■ ❑ Is storage appropriate for cylinders? ❑ ❑ ■ ❑ # Is de -chlorination substance stored away from chlorine containers? ❑ ❑ ■ ❑ Comment: Page # 4 Permit: NCO084212 Owner - Facility: Sparks Road WTP Inspection Date: 01/30/2014 Inspection Type: Compliance Evaluation nn-r-hlnr1n!a46%n Vac Nn NA NE Are the tablets the proper size and type? ■ ❑ ❑ ❑ Are tablet de -chlorinators operational? ■ ❑ ❑ ❑ Number of tubes in use? 2 Comment: The two dechlorinator tubes are located at the head of the flow monitoring structure. Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? ■ ❑ ❑ ❑ Is flow meter calibrated annually? ■ ❑ ❑ ❑ Is the flow meter operational? ■ ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ ■ ❑ Comment: The permit requires continuous flow recording per footnote 1 of the effluent limitation and monitoring requirements page. In addition, an annual calibration of the metering device is required. The ultrasonic meter with parshall flume was last calibrated by F'ortech on June 27, 2013. The average daily discharge from the Sparks Road WTP in 2013 was approximately 1.35 MGD. 01__ Vnc M. NA NF Is right of way to the outfall properly maintained? ■ ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? ■ ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ ■ ❑ Comment: The effluent is discharged into a ditch adjacent to the flow monitoring structure. The ditch leads to a tributary of the Yadkin River, class "WS-IV" waters of the Yadkin -Pee Dee River Basin. This tributary enters the river just downstream of the intake structure. Page # 5 Mickey, Mike From: Mickey, Mike Sent: Thursday, January 30, 2014 4:17 PM To: Berry, Stephen Subject: Sparks Road WTP - NC0084212 / WQ0028806 Stephen — Visited the WTP today and met with Mike Weir/ORC. They last applied residuals in 2005 (155 dry tons from one settling lagoon) and again in 2010 (270 dry tons from both lagoons). Roy Whitaker with EMA uses a boat and sludge judge to determine when solids need to be removed. No plans to pump in 2014 as storage in the two settling lagoons is still adequate. The facility has a single raw water storage lagoon. They pump to this lagoon from the intake structure at the Yadkin River. They only have to pump from the river a few days a week in order to fill the lagoon. They try to pump at times when the river is clearer, reducing the generation of excessive solids to the settling lagoons when the filters are backwashed. Mike Mickey Mike.Mickev@NCDENR.eov NC Division of Water Resources 585 Waughtown Street Winston-Salem, NC 27107 Phone: (336) 771-4962 FAX: (336) 771-4630 E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. L�� NCDENR North Carolina Department of Environment and Natural Resources Division of Water Resources Water Quality Programs Pat McCrory Thomas A. Reeder John E. Skvarla, III Governor Director Secretary August 19, 2013 Ms. Beth Dirks, Manager County of Davie 123 South Main Street Mocksville, NC 27028 Subject: NOTICE OF DEFICIENCY Sparks Road WTP Permit No. NCO084212 Davie County Dear Ms. Dirks: A review of the May 2013 Discharge Monitoring Report (DMR) revealed a violation of the following parameter: Parameter Date Re orte I Value Permit Limit Limit Type pH 5/21/13 9.17 S.U. 1 9.0 S.U. Daily Maximum Remedial actions should be taken to correct the cause(s) of this violation. The violations described above should be abated immediately and properly resolved. Unresolved violations may lead to the issuance of a Notice of Violation and/or assessments of civil penalties. Thank you for your attention to this matter. If you have any questions or require any additional information, please contact Mike Mickey at (336) 771-5000. cc: Mike Weir (via email: sparksrdwtp@yadtel.net) DWR Central Files WSRO N. C. Division of Water Resources / Winston-Salem Regional Office 585 Waughtown Street, Winston-Salem, NC 27107 Phone: 336-771-50001 FAX:336-771-4630 Customer Service: 1-877-623-6748 Internet: www.ncwaterquality.org An Equal Opportunity 1 Affirmative Action Employer Sincerely, W. Corey Basinger Winston Salem Regional Supervisor Surface Water Protection Section onrt NhCarohna ;Vatura"tf toring Frequency Violations Pe ' re a uencv Values Reported # of Violations Cover Sheet from Staff Member to Regional Supervisor DMR Review Record Facility: Permit/Pipe No.: MonthNear onthly Average Violations Parameter Permit Linn DMR Value %Over Limit We ail Violations Date Parameter Permit Limit/Tvpe DMR Value % Over Limit Date Parameter Other Violatio \ ca csp- C, � Date: Completed by: Regional Water Quality Supervisor Signoff: Date: /%D Month: MAY Year: 2013 NPDES Permit #NC0084212 Discharge No. 1 Class 1 County Davie Grade PC 1 Phone 336-998-9763 Certified Laboratories Tritest Inc. Operator in Responsible Charge: Michael Weir Person(s) Collecting Samples Operators: Michael Weir, Rodney McDaniel, Michael Miller &LU (f, `' - VlcYM By this signature, I certify that this report is accurate and (Sianature of Operator in Responsible charge) 1 Date complete to the best of my knowledge. . . . . . . . . . . . . . . . . . . . . . . I N.C.Dect. cf Ei`!R > s i2 5 '2121 Winston-Salem Regional 0-hca Facility Status: (Please check one of the following) 0 1k All monitoring data and sampling frequencies meet permit requirements All monitoring data and sampling frequencies do NOT meet permit requirements Compliant Noncompliant If the facility is noncompliant, please comment on corrective actions being taken in respect to equipment, operation, maintenance, etc., "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." Permittee Address Sparks Rd WTP CpimA Of Davie Pe e i el C. Weir) Signature of Permittee* D to Phone Number Permit Exp. Date 728 Sparks Rd Mocksville NC 336-998-9763 5-31-14 PARAMETER CODES 00010 Temperature 00076 Turbidity 00080 Color (Pt -Co) 00082 Color (ADMI) 00095 Conductivity 00300 Dissolved Oxygen 00310 BOD5 00340 COD 00400 pH 00530 Total Suspended Residue 00545 Settleable Matter 00556 Oil & Grease 00600 Total Nitrogen 00610 Ammonia Nitrogen 00625 Total Kjeldhal Nitrogen 00630 Nitrates/Nitrites 00665 Total Phosphorous 00720 Cyanide 00745 Total Sulfide 00927 Total Magnesium 00929 Total Sodium 00940 Total Chloride 00951 Total Fluoride 01002 Total Arsenic 01027 Cadmium 01032 Hexavalent Chromium 01034 Chromium 01037 Total Cobalt 01042 Copper 01045 Iron 01051 Lead 01067 Nickel 01077 Silver 01092 Zinc 01105 Aluminum 01147 Total Selenium 31616 Fecal Coliform 32730 Total Phenolics 34235 Benzene 34481 Toluene 38260 MBAS 39516 PCBs 50050 Flow 50060 Total Residual Chlorine 71880 Formaldehyde 71900 Mercury 81551 Xylene Parameter Code assistance may be obtained by calling the Water Quality Compliance Group at (919) 733-5083, extension 581 or 534. The monthly average for fecal coliform is to be reported as a GEOMETRIC mean Use only units designated in the reporting facility's permit for reporting data. *ORC must visit facility and document visitation of facility as required per 15A NCAC 8A0202 (b) (5) (B). ** If signed by other than the permittee, delegation of signatory authority must be on file with the state per 15A NCAC 2B .0506 (b) (2) (D)• AF-KWA MD FERR North Carolina Department of Environment and Natural Resources Division of Water Quality Pat McCrory Charles Wakild, P. E. John E. Skvarla, III Governor Director Secretary February 18, 2013 Ms. Beth Dirks, County Manager Davie County Administration Building 123 S Main Street Mocksville, NC 27028 SUBJECT: Compliance Evaluation Inspection Sparks Road WTP NPDES Permit No., NCO084212 Davie County Dear Ms. Dirks: Sue White of the Winston-Salem Regional Office performed a Compliance Evaluation Inspection (CEI) on the Sparks Road Water Treatment Plant on February 13, 2013. Michael Weir, ORC and Johnny Lambert, Director of Public Utilities were present for the inspection. The inspection consisted of two parts: an on -site inspection of the treatment facility and a file review. The following are the findings from the subject inspection: I. Permit The NPDES permit for the Spark Rd WTP became effective December 1, 2009 and will expire on May 31, 2014. Please be aware that the permit renewal application must be received by Division of Water Quality 180 days prior to the permit expiration date. The permitted components of the water treatment facility are two filter backwash lagoons with dechlorination. Solids from the settling lagoons are removed as necessary for land application under non - discharge permit number WQ0010528. II. Records/Reports A review of the laboratory reports and Discharge Monitoring Reports (DMRs) for the Sparks Road WTP showed no reporting violations during that period. The files and all required log books were on -site and in order. III. Facility Site Review The facility site review indicated that the treatment works is consistent with the permitted components. The actual treatment system consists of the abovementioned components. The filter backwash flow is estimated using a v-notch weir. North Carolina Division of Water Quality, Winston-Salem Regional Office Location: 585 Waughtown St. Winston-Salem, North Carolina 27107 One Phone: 336-771-5000 \ FAX: 336-771-4630 \ Customer Service: 1-877-623-6748 NofthCarohna Internet: www.ncwaterquality.org Natura/, p An Equal Opportunity \ Affirmative Action Employer `ad�� Ms. Beth Dirks, County Manager February 18, 2013 Page 2 of 2 If you have questions or comments regarding this inspection, or if this office can be of assistance, please contact Sue White at 336-771-5000. Sincerely, W. Corey Basinger Water Quality Supervisor Winston Salem Regional Office Cc: Davie County Health Department WSRO Central Files Johnny Lambert, Director of Public Works h United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCs) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 I N I 21 51 31 NC0084212 111 121 13/02/12 117 181 C I 19101 20 u !J lJ Remarks 21111111111111111111111111 1111 111111111111 IIII II16 Inspection Work Days Facility Self -Monitoring Evaluation Rating 131 QA -----------------Reserved ----------- --- 67I 169 70 U 71 IU 72 I N I 73' I' 74 751 I I I 11 I 180 L— W Section B: FacilityData Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 10:30 AM 13/02/12 09/12/01 Sparks Road WTP Exit Time/Date Permit Expiration Date 728 Sparks Rd Mocksville NC 27028 11:15 AM 13/02/12 14/05/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data /// Michael Christopher Weir/ORC/336-998-9763/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Johnny Lambert,261 Chaffin St Mocksville NC 27028/Director of Public Utilities/336-753-609L Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit N Flow Measurement Operations & Maintenance 0 Records/Reports Self -Monitoring Program N Facility Site Review Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Sue White WSRO WQ//336-771-5000/ Z // lg �(� ,L, Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page # 1 NPDES yr/mo/day Inspection Type 3I NCO084212 I11 12I 13/02/12 117 18' _' Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Page # 2 If Permit: NCO084212 Owner - Facility: Sparks Road WTP Inspection Date: 02/12/2013 Inspection Type: Compliance Evaluation Operations $ Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ■ ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge ■ ❑ ❑ ❑ Judge, and other that are applicable? Comment: Permit (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Comment: Yes No NA NE Page # 3 Mickey, Mike From: Mickey, Mike Sent: Friday, April 01, 2011 3:29 PM To: 'Sparks Road' Subject: RE: Flow That's great. Hadn't heard a word from John G. One heads up — "Continuous" recording means every day except for a state holiday. Make sure you report flow values for Saturday and Sunday or our computer system will churn out a NOV letter. Thanks, Mike. Mike Mickey Mike. Mickev(a)NCDENR.eov NC Division of Water Quality 585 Waughtown Street Winston-Salem, NC 27107 Phone: (336) 771-4962 FAX: (336) 771-4630 E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Sparks Road [mailto:sparksrdwtp@yadtel.net] Sent: Friday, April 01, 2011 2:56 PM To: Mickey, Mike Subject: Flow Mike, I wasn't sure if John Grey has informed you or not but figured I better just in case. We have finally gotten our continuous flow monitoring installed and running. It is recording flows onto our existing scada and everything seems to be running great. I appreciate the patience you had for us on this project and hope we are not put in this type of situation again. Again, thanks and I hope you have a great weekend, I know I will, trout season is opening up and I am still waiting for turkey season to get here! Michael C. Weir ORC Sparks Rd WTP Davie County Public Utilities 728 Sparks Rd Mocksville, NC 27028 ph:336-998-9763 fax: 336-998-2272 cell: 336-477-5037 z �vpw„Q Cover Sheet from `� e ��� Staff Member to -� Regional Supervisor DnZR Review Record ' Facility: f�5 b � Permit/Pipe No.: ��1;�0�3�`�`� Month/Year Mwthly Average Violations Parameter Permit Lirnit' DMR Value % Over Limit �Iy iolations Date Parameter Permit Lin-fit/Type �o �b A. Date Moni Parameter Other Violations DMR Value % Over Limit Frequency Violations 3Vb NA\ Values Reported # of Violations Completed by: " \ !��Date: . I � V Regional Water Quality Supervisor Signoff: Date: bpi Month: APRIL _ Year: 2011 NPDES Permit #NC0084212 - - Rr Discharge No. 1 Class 1 County Davie Gradd PC 1 Phone 336-998-9763 Certified Lab atories Tritest Inc. Operator in Responsible Charge: Michael Weir rson(s) Collecting Samples Operators: Michael Weir, Rodney Mcdanial, Michael Miller UN David Nobles I vrnscon-sale- /`,q Cam/ ( By this signature, I certify that this report tfafe and IL . •. .. .. a - .. r. . .- . -. i. .. UHHHUHUH • opt.+rmaiior. rroces#,,� "nA DIA) TOG Facility Status: (Please check one of the following) All monitoring data and sampling frequencies meet permit requirements Compliant All monitoring data and sampling frequencies do NOT meet permit requirements Noncompliant If the facility is noncompliant, please comment on corrective actions being taken in respect to equipment, operation, maintenance, etc., and a timetable for improvements to be made. "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations" Permittee Address 728 Sparks Rd Mocksville NC 00010 Temperature 00076 Turbidity 00080 Color (Pt -Co) 00082 Color (ADIvII) 00095 Conductivity 00300 Dissolved Oxygen 00310 BOD5 00340 COD 00400 pH 00530 Total Suspended Residue 00545 Settleable Matter 00556 Oil & Grease 00600 Total Nitrogen 00610 Ammonia Nitrogen Sparks Rd VaP County Of Davie Pe iae . Weir Si tune of Permittee* Date Phone Number 336-998-9763 PARAMETER CODES 00625 Total Kjeldhal Nitrogen 00630 Nitrates/Nitrites 00665 Total Phosphorous 00720 Cyanide 00745 Total Sulfide 00927 Total Magnesium 00929 Total Sodium 00940 Total Chloride 00951 Total Fluoride 01002 Total Arsenic 01027 Cadmium 01032 Hexavalent Chromium 01034 Chromium 01037 Total Cobalt 01042 Copper 01045 Iron 01051 Lead 01067 Nickel 01077 Silver 01092 Zinc 01105 Aluminum 01147 Total Selenium 31616 Fecal Coliform 32730 Total Phenolics Permit Exp. Date 5-31-14 34235 Benzene 34481 Toluene 38260 MBAS 39516 PCBs 50050 Flow 50060 Total Residual Chlorine 71880 Formaldehyde 71900 Mercury 81551 Xylene Parameter Code assistance may be obtained by calling the Water Quality Compliance Group at (919) 733-5083, extension 581 or 534. The monthly average for fecal coliform is to be reported as a GEOMETRIC mean. Use only units designated in the reporting facility's permit for reporting data. *ORC must visit facility and document visitation of facility as required per 15A NCAC 8A.0202 (b) (5) (B). ** If signed by other than the permittee, delegation of signatory authority must be on file with the state per 15A NCAC 2B .0506 (b) (2) (D)• Mickey, Mike From: Sparks Road [spa rksrdwtp@yadtel. net] Sent: Monday, February 21, 2011 9:45 AM To: Mickey, Mike Subject: Ammended Copy Mike, just wanted to follow up that you received the fax for the Amended Copy for Nov 2010. If you would like a hard copy can mail you one, just let me know. Also please update my contact info or the info for Sparks Rd. Wtp since I have a new email address. The mweir(a)-yadtel.net is my personal email address and anything from here on out that is business related send to our county email address ssparksrdwtp(c)-vadtel.net Thanks again for the understanding of the flowmeter. Michael C. Weir ORC Sparks Rd WTP Davie County Public Utilities 728 Sparks Rd Mocksville NC, 27028 P: 336-998-9763 C: 336-477-5037 F: 336-998-2272 Mickey, Mike From: mweir@yadtel.net Sent: Friday, February 18, 2011 11:14 AM To: Mickey, Mike Subject: Re: November Monitoring Report Mike I will check I am almost positive I caught it and sent in a revised red copy in with the month of decembers. Yes I have the data, Miller didn't probably look in the 2010 binder in my office on bookshelf. We keep the current 2011 binder at work station. I will check first thing monday morning, I would also like to talk with you about the lagoon effluent flow monitoring debacle we have going on. Mike Weir Sent from my BlackBerry R smartphone with Nextel Direct Connect From: "Mickey, Mike" <mike.mickey@ncdenr.gov> Date: Fri, 18 Feb 2011 10:43:45 -0500 To: mweir(u�yadtel.net<mweir@yadtel.net> Subject: November Monitoring Report Mike —The November 2010 monitoring report (DMR) did not have any total residual chlorine values listed. Was the sampling performed? I called Friday and talked to Michael Miller but he could not locate the results. If it wasn't performed, we will have to send a Notice of Violation for omitted monitoring. If it was performed but simply not transcribed onto the DMR, we just need a corrected copy sent to Central Files with the data added. Let me know what you find out. Thanks, Mike. Mike Mickey Mike.Mickev(ZDNCDENR.eov NC Division of Water Quality 585 Waughtown Street Winston-Salem, NC 27107 Phone: (336) 771-4962 FAX: (336) 771-4630 E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. 02/21/2011 10:38 13369922272 SPARKS RD WTP PAGE 01 Effluent Sparks Road WTP ��� Q� Month: NOVEMBER . Year: 2010 �l NPDES Permit #N Q9 Discharge No. 1 Class 1 County Davie Grade PC 1 Phone 336-998-9763 Certifled Laporatories Tritest Inc. Operator in Responsible Charge: Michael Weir Person(s) Collecting Samples Operators: Michael Weir, Rodney Mcdanial, Michael Miller i David Nobles C. � ? 1 By this signature, I certify that this report is accurate and (Signature of ODerator in Responsible charge) to complete to the best of my knowledge. m m �' E N i= c 0 E E c `o C O r0 a U O Ai p 1 2 3 4 9 an T2 13 19 20 26 28 29 30 31 0900 1 3.001 Y 1300 1 2.001 Y 0800 1 3.001 Y 0900 1 2.001 Y Average Maximum Minimum ;omp. (C) / Grab G) Daily Max Monthly Ayg. IBM���®�������� EM om0�090128M0®l r fffmv AMMENDED COPY: TOTAL RESIDUAL CHLORINE WAS INADVERTANLY OMITTED 02/21/2011 10:38 13369982272 SPARKS RD WTP PAGE 02 Facility Status: (please Check One of the iblloaring) All monitoring data and sampling ftquoda meet permit nqWmnaft Hendee do NOT meet t r$q� AU momtonng data ad sampling i�eq P� NoOoo MPUM If the facility is noncompliant, Please comment on oonwtive actions being talcen in A"pW to ogtdpment, operdiov, do,, and a timetable for impravements to be made- " I certify, under penalty of law, that this document and all atmcbmems were prepared under my direcd,on or tupetvislon in ao0ordertoe with a system dcsiSnod to assure that qualii%d personnel properly Sather and evaivato the information submitted Haled on my inquiry of the person or persons who manage the system, or those persons directly respondble fr ®therinS the hdxmsdon, ft information submitted is, to the best of my knowledge and belief, mre, accurate, and Complete. I am gaffe that there are 4ditent penalties for submi=g false information, inchtftg the possibility of fines and imprimmlt'dt for Imowing violedws." Fmok Exp. DOW 728 Spats Rd lulockmme NC 336-99&9763 5-31.14 PABAi!►tMM DODFB 00010 Temperature OW76 Tufaidily 00080 Color QN-Co) 00082 Odor (ADW 00310 HODS 00340 COD 00400 pH OOS30 Tod SmpmabdRadd■c 0054S SedeakHussar 00556 OR & CieMsa OOti00 Tbd MtoAes 00610 Au min 00625 Taal Kjddhd NUMM 00630 bi'uratra/14a 0060 Total Pbo 00720 C. mMc 00745 Triad WE* 00927 Told Maw 00929 Tud SoMM 00910 Tmd cblod& 00951 ToldFbacde 01002 Tod Aoteaic 01027 Cad■ 01092 Aaxaval M Chromium 01034 ClromhW 01037 Toml Cobalt 01042 Copper' 01045IM 01051 Lead 01067 Nicbti 01077 sam 01092 Talc 0110E AImaittsIN 01147 Total SdU9M 31616 Feral C WWM 32730 .Tod Proles 34235 BCWM 34461 TdhaM 35M IMAS M16 PCBs 50050 Plow ""TOW Ral" Cuoda 71M Fatadddo* 71"O bo ' sm Xplkaa Parameter Co& mono moc maybe obtm"by COMM Ik WaW QMW CAMOINICO QaoW 0 019) 17MM, ewes" MI @[ "4r Tice- a 16 awcow rwjenl auffibmisto be I m 0 GBOMMW ntrasa. UM d* 2IN%I dOiPOW il dwUVOOft sPaaakft ddL #QtC s�ettvisbfic+�� aridou■att� af'�s s+�ia+dpar 1SA1sCAC SA�2 � (� t� *'` �tigat�dttipertrep�i�t; &it�caaafsr0tantpaaiatit��ttbt: a flteriftttic �cgr 1.fA II�Aty ZiR .t9�i � � �11- Mickey, Mike From: Mickey, Mike Sent: Friday, February 11, 2011 8:37 AM To: mweir@yadtel. net' Cc: 'jgrey@greyengineering.com' Subject: Sparks WTP Mike — John Grey called this week concerning the new flow monitoring installation. No problem if it is running behind. However, since the permit requires continuous recording beginning March 1, 2011, you will need to start reporting daily instantaneous flows on the monitoring reports beginning in March. That will keep our computer system will be happy. Holler if you have any questions. Mike. Mike Mickey Mike.MickevCcDNCDENR.eov NC Division of Water Quality 585 Waughtown Street Winston-Salem, NC 27107 Phone: (336) 771-4962 FAX: (336) 771-4630 E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. / 4 MCA, January 27, 2010 System Performance Annual Report DWQ 1617 Mail Service Center Raleigh, NC 27699-1617 Subject: 2009 System Performance Annual Report To Whom It May Concern: RECEIVED F C. Deot. of ENR B 17 2010 inston-Salem egional Office In 2009 our facility showed exceptional performance in meeting all laws, regulations and rules pertaining to water quality. Our NPDES permit # NCO084212 expired on 5/31/2009 and was reissued on 12/1/2009. The NPDES permit is issued to Davie County at the Sparks Road Water Treatment Plant and covers the operation of two parallel 785,000 gallon filter backwash lagoons. Many new parameters have been added to our new permit so 2010 will be exciting for us as we look forward to the challenge of all the extra testing envolved. During 2009, Davie County had no violations and we met all or monitoring data and sampling requirements for the year. A chart of our 2009 annual averages and annual max for our monitoring data is found below. 2009 Annual Average Annual Max Daily Flow .157 MGD .326 MGD TSS 2.04 mg/I 7 mg/I Settable Solids 0 ml/I 0 ml/I Iron .480 m /I 1.11 m /I Total Residual C12 4.2 ug/I 7 ug/I Upstream Turb. 7.76 NTU 124 NTU Downstream Turb. 4.59 NTU 37.1 NTU We are excited to bring this 2009 system performance report to you and look forward to making 2010 a even better year in the performance of our system. Sincerely, Mi Weir O�C Sparks Rd. WTP Davie County, NC Mickey, Mike From: mweir@yadtel.net Sent: Monday, January 24, 2011 4:19 PM To: Mickey, Mike Subject: Re: Annual Report Whoohoo, guess it is a trade off for some of the useless samples I'm required to take. Wink -wink.... Also noticed you still have my old email address, my new one is sparksrdwtpgyadtel.net Hope you had a great New Year and will see you soon. Mike Sent from my BlackBerry R smartphone with Nextel Direct Connect From: "Mickey, Mike" <mike.mickev cc ncdenr.gov> Date: Mon, 24 Jan 2011 16:00:02 -0500 To: mweir@yadtel.net<mweiryadtel.net> Subject: Annual Report Mike — Saw your 2010 annual report come through. Thought I should let you know that this summer the legislature amended the law so that annual reports are now only required from municipal/domestic facilities with an average annual flow greater that 200,000 gpd. Since the WTP does not treat municipal or domestic wastewater, you should be done with annual reports. See cite below. Mike. § 143-215.1C. Report to wastewater system customers on system performance; publication of notice of discharge of untreated wastewater and waste. (a) Report to Wastewater System Customers. — The owner or operator of any wastewater collection or treatment works, the operation of which is primarily to collect or treat municipal or domestic wastewater and for which a permit is issued under this Part and having an average annual flow greater than 200,000 gallons per day, shall provide to the users or customers of the collection system or treatment works and to the Department an annual report that summarizes the performance of the collection system or treatment works and the extent to which the collection system or treatment works has violated the permit or federal or State laws, regulations, or rules related to the protection of water quality. The report shall be prepared on either a calendar or fiscal year basis and shall be provided no later than 60 days after the end of the calendar or fiscal year. Mike Mickey Mike.Mickev@NCDENR.gov NC Division of Water Quality 585 Waughtown Street Winston-Salem, NC 27107 Phone: (336) 771-4962 FAX: (336) 771-4630 E-mail correspondence to and from this address may be subject to the North /WA6 M January18 2011 RECEIVED N.C. Deot. of ENa System Performance Annual Report JAN 2 4 2011 NC DENR / DWQ / Central Files 1617 Mail Service Center T Raleigh, NC 27699-1617 Subject: 2010 System Performance Annual Report To Whom It May Concern: In 2010 our facility showed exceptional performance in meeting all laws, regulations and rules pertaining to water quality. Our NPDES permit # NCO084212 was reissued on 12/1/2009 and expires 5/31/2014. The NPDES permit is issued to Davie County at the Sparks Road Water Treatment Plant and covers the operation of two parallel 785,000 gallon filter backwash lagoons. During 2010, Davie County had no violations and we met all or monitoring data and sampling requirements for the year. A chart of our 2010 annual averages and annual max for our monitoring data is found below. 2010 Annual Average Annual Max Daily Flow .170 MGD .326 MGD TSS 4.25 mg/1 11 mg/1 Fluoride .39 mg/1 .49 mg/1 Turbidity 3.27 ntu 10.8 ntu Iron .459 mg/1 .625 mg/1 Total Residual C12 2.76 u /1 5 u /1 ph 7.33 8.62 Aluminum .028 mg/1 .065 mg/1 Manganese .189 mg/1 .338 mg/1 Total Zinc .020 mg/1 .040 m /1 Total Copper <.010 <.010 Total Nitrogen .675 mg/1 1.170 mg/1 Total Phosphorous .012 mg/1 .030 mg/1 Toxicity P P o PS WP= JAN 19 2011 s DE ,', : ;r:'E L 1_ Q?i1ALITY POi1V`i SOUR BRANCH We are excited to compile this 2010 system performance report for you and look forward to making 2011 an even better year in the performance of our system. Sincerely, Michael C. Weir ORC Sparks Rd. WTP Davie County, NC 4 NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Governor Ms. Beth Dirks, Manager County of Davie 123 South Main Street Mocksville, NC 27028 Coleen H. Sullins Director March 26, 2010 SUBJECT: Compliance Evaluation Inspection Davie County - Spark Road WFP NPDES Permit No. NCO084212 Davie County Dear Ms. Dirks: Dee Freeman Secretary On March 23, 2010, Mike Mickey of this office met with Michael Weir, ORC,' to perform a Compliance Evaluation Inspection on the NPDES wastewater discharge from the Sparks Road water treatment plant. This type of inspection consists of two basic parts: an in office file review and an on -site inspection of the treatment facility. The attached EPA inspection form notes the seven (7) areas that were evaluated for this inspection. The findings and observations are outlined below: I. Permit The NPDES permit was reissued on December 1, 2009. Footnote "1" on the Effluent Limitations page of the new permit states that continuous flow monitoring becomes effective on March 1, 2011. It is our understanding that plans are already underway to install a flow meter at the start of the next fiscal year. II. Self -Monitoring_ Program Monthly self -monitoring reports were reviewed for the period January 2009 through December 2009. The facility was found to be in complete compliance with all effluent limits for this time period (see data summary attached). In addition, all monitoring was performed per the frequencies specified in the permit. Field parameter certification was recently renewed for on -site testing of total residual chlorine. Approval for on -site pH testing is pending. III. Flow Measurement Flow from the settling lagoons is currently estimated using the v-notch weir on the end of the discharge pipe. North Carolina Division of Water Quality, Winston-Salem Regional Office Location: 585 Waughtown St. Winston-Salem, North Carolina 27107 Phone: 336-771-50001 FAX: 336-771-46301 Customer Service: 1-877-623-6748 Internet: www.ncwaterquality.org An Equal Opportunity 1 Affirmative Action Employer NorthCarohna fah rq!!ff Ms. Beth Dirks Page 2 March 26, 2010 IV. Facility Site Review Wastewater generated from clarifier and filter backwash is routed to two 785,000 gallon settling lagoons in parallel. The supernatant overflow is dechlorinated prior to discharge. The facility plans to remove solids from one settling lagoon this year for land application under permit number WQ0028806. V. Operations & Maintenance The operation and maintenance of the facility appeared to be excellent. No concerns were noted. VI. Records/Reports A review of the facility files showed that all records are being maintained according to the permit and that all monitoring was performed per the frequencies listed in the NPDES permit. In addition, the 2009 annual report was submitted as required. VII. Effluent/Receiving Waters The system discharges into an unnamed tributary to the Yadkin River, Class "WS-IV" waters. The effluent was crystal clear on the day of the inspection. Should you have any questions concerning this report, please contact Mike Mickey or me at (336) 771-5000. Sincerely, Steve W. Tedder Water Quality Regional Supervisor cc: Johnny Lambert (Director of Public Utilities, Davie County, 261 Chaffin Street, Mocksville, NC 27028) Michael Weir (Sparks Road WTP, 728 Sparks Road, Mocksville, NC 27028) Central Files WSRO Davie County - Sparks Road WFP NPDES Permit No. NCO084212 Self -Monitoring Data Summary January 2009 — December 2009 Parameters Monthly Avg. Permit Limit Monthly Avg. Limit Violations per DMR Daily Maximum Permit Limit Daily Max. Limit Violations per DMR Flow (MGD) - NA - NA TSS (mg/1) 30.0 None 45.0 None R. Chlorine (ug/1) - NA 17.0* None pH (S.U.) - NA (6.0 — 9.0) range None Chronic Toxicity P/F @ 90% None - NA *Note: any value below 50 ug/1 is considered to be compliant United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 U NI 2 I S 31 NCO084212 111 121 10/03/23 117 181 cl 191 GI 201 '--' U L l= l U U Remarks 21111111111111111111111111111111111111111111111116 Inspection Work Days Facility Self -Monitoring Evaluation Rating 61 CA --------------------------- Reserved ---------------------- 671 169 70 U 5 71 U 72 73 L Lj 74 751 1 1 1 1 1 1 1 80 t�-1r �--� Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 09:00 AM 10/03/23 09/12/01 Sparks Road WTP Exit Time/Date Permit Expiration Date 728 Sparks Rd Mocksville NC 27028 10:20 AM 10/03/23 14/05/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Michael Christopher Weir/ORC/336-998-9763/ Name, Address of Responsible Official/Title/Phone and Fax Number cc Johnny Lambert,261 Chaffin St Mocksville NC 27028/Director of Publ'ctaCted Utilities/336-753-6090/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Flow Measurement Operations & Maintenance 0 Records/Reports Self -Monitoring Program E Facility Site Review Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Michael M Mickey , WSRO WQ//336-771-5000/ Signature of Ma gement Q A R r4wer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page # 1 Permit: NCO084212 Owner - Facility: Sparks Road WTP Inspection Date: 03/23/2010 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new application? ❑ ❑ ■ ❑ Is the facility as described in the permit? ■ ❑ ❑ ❑ # Are there any special conditions for the permit? ■ ❑ ❑ ❑ Is access to the plant site restricted to the general public? ■ ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? ■ ❑ ❑ ❑ Comment: The NPDES permit was reissued effective December 1, 2010. Footnote "1" on the Effluent Limitations page specifies that continuous flow monitoring be installed by March 1, 2011. Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ■ ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge ❑ ❑ ■ ❑ Judge, and other that are applicable? Comment: The operation and maintenance of the facility appeared excellent. Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? ■ ❑ ❑ ❑ Is all required information readily available, complete and current? ■ ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? ■ ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? ■ ❑ ❑ ❑ Is the chain -of -custody complete? ■ ❑ ❑ ❑ Dates, times and location of sampling ■ Name of individual performing the sampling ■ Results of analysis and calibration ■ Dates of analysis ■ Name of person performing analyses ■ Transported COCs ■ Are DMRs complete: do they include all permit parameters? ■ ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ■ ❑ ❑ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? ❑ ❑ ■ ❑ Is the ORC visitation log available and current? ■ ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? ■ ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility classification? ■ ❑ ❑ ❑ Page # 3 Permit: NCO084212 Owner - Facility: Sparks Road WTP Inspection Date: 03/23/2010 Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE Is a copy of the current NPDES permit available on site? ■ ❑ ❑ ❑ Facility has copy of previous year's Annual Report on file for review? ■ ❑ ❑ ❑ Comment: The operators records were found to be thorough and complete. The 2009 annual report was timely submitted as required. Two total residual chlorine values were accidently left off the December 2009 DM R. A corrected report is to be resubmitted to Central Files. ne_..ti��a..�•a,,., Yes No NA NE Type of system ? Tablet Is the feed ratio proportional to chlorine amount (1 to 1)? ❑ ❑ ■ ❑ Is storage appropriate for cylinders? ❑ ❑ ■ ❑ # Is de -chlorination substance stored away from chlorine containers? ❑ ❑ ■ ❑ Comment: Are the tablets the proper size and type? ■ ❑ ❑ ❑ Are tablet de -chlorinators operational? ■ ❑ ❑ ❑ Number of tubes in use? 1 Comment: The dechlorination unit has a single tube. Flow Measurement- Effluent Yes No NA NE # Is flow meter used for reporting? ❑ ■ ❑ ❑ Is flow meter calibrated annually? ❑ ■ ❑ ❑ Is the flow meter operational? ❑ ■ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ ■ ❑ Comment: The permit requires continuous flow monitoring to be installed on or before March 1, 2011. Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? ■ ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? ■ ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ ■ ❑ Comment: Effluent from the two settling lagoons is discharged into a ditch along the gravel road that leads to the intake structure. Page # 4 NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Governor Director January 4, 2010 5462 i JAN 1 12010 Mr. Michael C. Weir Winston-Salem Davie Co. Water - Sparks Rd. WTP Regional Office 728 Sparks Rd. Mocksville, NC 27028- Dee Freeman Secretary Subject: North Carolina Wastewater/Groundwater Laboratory Certification (NC WW/GW LC) Maintenance Inspection Dear Mr. Weir : Enclosed is a report for the inspection performed on November 10, 2009 by Mr. Ramon Cook. Where finding(s) are cited in this report, a response is required. Within thirty days of receipt, please supply this office with a written item for item description of how these finding(s) were corrected. If the finding(s) cited in the enclosed report are not corrected, enforcement actions may be recommended. For certification maintenance, your laboratory must continue to carry out the requirements set forth in 15A NCAC 2H .0800. Copies of the checklists completed during the inspection may be requested from this office. Thank you for your cooperation during the inspection. If you wish to obtain an electronic copy of this report by email or if you have questions or need additional information, please contact us at 919-733-3908. rely, Dana terwhite Certif" ation Unit Supervisor Laboratory Section Enclosure cc: Ramon Cook Winston-Salem Regional Office DENR DWQ Laboratory Section NC Wastewater/Groundwater Laboratory Certification Branch 1623 Mail Service Center, Raleigh, North Carolina 27699-1623 Location: 4405 Reedy Creek Road. Raleigh, North Carolina 27607-6445 Phone: 919-733-39081 FAX: 919-733-6241 Internet: www.dwglab.org Nne orthCarohna Naturally An Equal Opportunity 1 Affirmative Action Employer Customer Service: 1-877-623-6748 www.ncwaterquality.org LABORATORY NAME: WATER QUALITY PERMIT #: ADDRESS: CERTIFICATE #: DATE OF INSPECTION: TYPE OF INSPECTION: AUDITOR(S): LOCAL PERSON(S) CONTACTED: INTRODUCTION: On -Site Inspection Report Davie Co. Water - Sparks Rd. WTP NCO084212 728 Sparks Road Mocksville, NC 27028 5462 November 10, 2009 Field Maintenance Ramon L. Cook Michael Weir This laboratory was inspected to verify its compliance with the requirements of 15A NCAC 2H .0800 for the analysis of environmental samples. II. GENERAL COMMENTS: The records were well organized and concise. The facility has all the equipment necessary to perform the analyses. A few additional quality control procedures need to be implemented. Mr. Weir has requested the deletion of Settleable Residue — Standard Methods, 18th Edition, 2540 F from his certificate immediately, and is requesting the addition of pH — Standard Methods, 18th Edition, 4500 H+ B in 2010. Certification for pH will be granted when an acceptable performance testing sample is submitted to this office directly from an approved vendor. III. FINDINGS, REQUIREMENTS, COMMENTS AND RECOMMENDATIONS: Settleable Residue — Standard Methods, 18th Edition, 2540 F Total Residual Chlorine — HACH Method 10014 ULR A. Finding: The sampling site is not documented on the benchsheet. Requirement: Data pertinent to each analysis must be maintained for five years. Certified Data must consist of date collected, time collected, sample site, sample collector, and sample analysis time. The field benchsheets must provide a space for the signature or initials of the analyst, and proper units of measure for all analyses. Ref: 15A NCAC 2H .0805 (g) (1). Total Residual Chlorine — HACH Method 10014 ULR B. Finding: The laboratory is not recording the check standard analysis time. Page 2 #5462 Davie Co. Water - Sparks Rd. WTP Requirement: Data pertinent to each analysis must be maintained for five years. Certified Data must consist of date collected, time collected, sample site, sample collector, and sample analysis time. The field benchsheets must provide a space for the signature or initials of the analyst, and proper units of measure for all analyses. Ref: 15A NCAC 2H .0805 (g) (1) and Technical Assistance for Field Analysis of Total Residual Chlorine. IV. PAPER TRAIL INVESTIGATION: The paper trail consisted of comparing field testing records and contract lab reports to Discharge Monitoring Reports (DMRs) submitted to the North Carolina Division of Water Quality. Data were reviewed for Davie Co. Water - Sparks Rd. WTP for the months of August, September, and November, 2009. No transcription errors were detected. The facility appears to be doing a good job of accurately transcribing data. V. CONCLUSIONS: Correcting the above -cited findings will help this lab to produce quality data and meet certification requirements. The inspector would like to thank the staff for its assistance in the inspection and data review process. Please respond to all findings. Report prepared by: Ramon L. Cook Date: December 11, 2009 Report reviewed by: Todd Crawford Date: December 14, 2009 f Aja NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Governor Director Secretary December 23, 2009 RECEIVED N.C. De o/ENR 5462 DEC 3 � Mr. Michael C. Weir Davie Co. Water - Sparks Rd. WTP Winston SaIem 728 Sparks Rd. Resronat °�� I Mocksville, NC 27028- SUBJECT: Wastewater/Groundwater Laboratory Certification Renewal FIELD PARAMETERS ONLY Dear Mr. Weir: The Department of Environment and Natural Resources, in accordance with the provisions of NC GS 143-215- .3 (a) (10), 15 NCAC 2H .0800, is pleased to renew certification for your laboratory to perform specified environmental analyses required by EMC monitoring and reporting regulations 15 NCAC 2B .0500, 2H .0900 and 2L .0100, .0200, .0300, and 2N .0100 through .0800. Enclosed for your use is a certificate describing the requirements and limits of your certification. Please review this certificate to insure that your laboratory is certified for all parameters required to properly meet your certification needs. Please contact us at 919-733-3908 if you have questions or need additional information. Sincerellyy, v Pat Donnelly Certification Branch Manager Laboratory Section Enclosure cc: Ramon Cook Dana Satterwhite Winston - Salem Regional Officef DENR DWQ Laboratory section NC Wastewater/Groundwater Laboratory Certification Branch 1623 Mail Service Center, Raleigh, North Carolina 27699-1623 Location: 4405 Reedy Creek Road. Raleigh, North Carolina 27607-6445 Phone: 919-733-39081 FAX: 919-733-6241 Internet: www,dwglab.org An Equal OpportunitylAffirmative Action Employer Customer Service:1-877-623-6748 www.ncwaterquality.org NorthCarohna Natumllf STATE OF NORTH CAROLINA DEPARTMENT OF THE ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY LABORATORY CERTIFICATION PROGRAM In accordance with the provisions of N.C.G.S. 143-215.3 (a) (1), 143-215.3 (a)(10) and NCAC 2H.0800: 2010 DAVIE CO. WATER - SPARKS RD. WTP Is hereby certified to perform environmental analysis as listed on Attachment I and report monitoring data to DWQ for compliance with NPDES effluent, surface water, groundwater, and pretreatment regulations. By reference 15A NCAC 2H .0800 is made a part of this certificate. This certificate does not guarantee validity of data generated, but indicates the methodology, equipment, quality control procedures, records, and proficiency of the laboratory have been examined and found to be acceptable. This certificate shall be valid until December 31, 2010 Certificate N 5462 Pat Donnelly r + Attachment I North Carolina Wastewater/Groundwater Laboratory Certification Certified Parameters Listing Lab Name: Davie Co. Water - Sparks Rd. WTP Certificate Number: 5462 Address: 728 Sparks Rd. Effective Date: 01/01/2010 Mocksville, NC 27028- Expiration Date: 12/31/2010 Date of Last Amendment: The above named laboratory, having duly met the requirements of 15A NCAC 2H.0800, is hereby certified for the measurement of the parameters listed below. CERTIFIED PARAMETERS INORGANICS RESIDUAL CHLORINE Hach Method 10014 ULR This certification requires maintance of an acceptable quality assurance program, use of approved methodology, and satisfactory performance on evaluation samples. Laboratories are subject to civil penalties and/or decertification for infractions as set forth in 15A NCAC 2H.0807. Mickey, Mike From: Basinger, Corey Sent: Tuesday, January 05, 2010 9:58 AM To: Boone, Ron; Carter, Jenifer; Douglas, Kristie; Euliss, Amy; Graznak, Jenny; Homewood, Sue; Hudson, Gary; Iverson, John; Mauney, Steve; Mickey, Mike; Pruitt, Rose; Smith, George; Stokes, Marc; Tedder, Steve; Wanucha, Dave; White, Sue; Yocum, Tom Subject: FW: NPDES WTP/Flow Limit Removal Attachments: ATT00001.c Corey Basinger, Environmental Engineer Corey.Basinger@ncdenr.gov NC DENR Division of Water Quality 585 Waughtown Street Winston-Salem, NC 27107 (336) 771-5000 Fax (336) 771-4630 E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Tedder, Steve Sent: Tuesday, January 05, 2010 9:50 AM To: Basinger, Corey Subject: FW: NPDES WTP/Flow Limit Removal send to all wq staff From: Belnick, Tom [tom.belnick@ncdenr.gov] Sent: Monday, January 04, 2010 4:40 PM To: denr.dwq.supvswp@lists.ncmail.net Cc: Matthews, Matt; denr.dwq.westnpdes; DENR.DWQ.EASTNPDES; Poupart, Jeff Subject: NPDES WTP/Flow Limit Removal This topic was briefly discussed at the SWPS breakout on 10/1/2009. NPDES has since updated the Water Treatment Plant permitting strategy to remove flow limits on all WTPs (flow monitoring requirement will remain). Unlike WWTPs, flow data was not critical for treatment design purposes, and NPDES still has use of DMR flow data to conduct RPA analysis. Also, the WTP strategy still precludes any new or expanding RO/IE plants to freshwater streams. Given the number of WTPs with existing flow limits (approx 115) and potential cost for public notice to remove limit, NPDES is proposing to remove existing WTP effluent flow limits upon permit renewal. It is recommended that Regions use BPJ for any flow violations associated with water treatment plants, until the limits are eventually removed at permit renewal. Let me know if you have any questions. Tom Belnick Supervisor, NPDES West Program NC DENR/Division of Water Quality 1617 Mail Service Center, Raleigh, NC 27699-1617 (919) 807-6390; fax (919) 807-6495 E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. Davie County Public Utilities Sparks Rd. WTP 728 Sparks Rd. Mocksville, NC 27028 May 12, 2009 Mr. Bob Sledge NCDENR Division of Water Quality Point Source Branch 1617 Mail Service Center Raleigh, NC 27699-1617 Subject: Draft NPDES Permit Comments NPDES Permit NC0084212 Davie County — Sparks Road WTP Dear Mr. Sledge: Upon reviewing our draft NPDES permit NC0084212 we have some concerns regarding the changes to our monitoring requirements. We acknowledge the changes but are requesting some of the limits and monitoring requirements be adjusted to better suit our facility. Our first concern pertains to the monthly average flow limit of 0.023 MGD for our facility. We believe that this limit is a typo and should actually be 0.230 MGD. Our previous permit allowed us to take weekly instantaneous flow readings from our 45-degree v-notch weir. With the monitoring requirement changing to continuous we will have to upgrade our facility with a more accurate flow -measuring device that can communicate to our scada system for data collection. After reviewing historical plant data we have on the amount of plant discharge to our lagoons and with the installation of a more accurate flow -measuring device we feel that during some months we will not be able to meet the 0.230 MGD monthly average flow limit. With these concerns we are asking that this monthly average flow limit be increased to 0.360 MGD. I have attached a simple excel spreadsheet that shows our monthly data taken from the v-notch weir versus the data we have in the plant pertaining to backwash sent to the lagoons. This data does not take into account filter wasting that may take place during plant operations. The highlighted data indicates months that we would not meet our proposed now limit requirements of .230 average mgd. Another concern is with the increased amount of effluent characteristics being sampled and monitoring frequencies. We would like to see footnote 4 be added to Aluminum, Total Zinc, Total Copper, Total Iron, and Whole Effluent Toxicity. After sufficient data has been collected we would like the opportunity to request a review of reasonable potential for monitoring and effluent limitations as stated in footnote 4. Davie County Public Utilities strives to protect our watershed and we will continue to do everything in our power to meet our NPDES permit requirements. Best regards, Michael C. Weir Sparks Rd. WTP ORC Davie County Public Utilities Office: 336-998-9763 Cell: 336-477-5037 Fax: 336-998-2272 Email: mweir@yadtel.net Flow for Sparks Rd. WTP Lagoons 45 degree v-notch weir Plant Discharge to lagoons Avg.mgd Max Total gals days Avg. gals Avg.mgd Jan-07 0.184 0.243 5,655,054 31 182,421 0.18 Feb-07 0.121 0.174 4,426,236 28 158,080 0.16 Mar-07 0.100 0.174 5,825,136 31 187,908 0.19 Apr-07 0.181 0.243 5,867,856 30 195,595 0.20 May-07 0.122 0.243 5,886,618 31 189,891 0.19 Jun-07 0.177 0.243 7,691,298 30 256,377 0.26 Jul-07 0.135 0.174 5,262,762 31 169,767 0.17 Aug-07 0.101 0.118 6,103,812 31 196,897 0.20 Sep-07 0.111 0.174 6,051,300 30 201,710 0.20 Oct-07 0.101 0.118 4,649,598 31 149,987 0.15 Nov-07 0.170 0.243 7,898,346 30 263,278 0.26 Dec-07 0.163 0.243 5,590,230 31 180,330 0.18 Jan-08 0.123 0.174 5,482,968 31 176,870 0.18 Feb-08 0.086 0.118 4,810,224 29 165,870 0.17 Mar-08 0.111 0.174 5,444,874 31 175,641 0.18 Apr-08 0.146 0.243 5,172,492 30 172,416 0.17 May-08 0.111 0.174 6,198,714 31 199,959 0.20 Jun-08 0.163 0.243 9,743,310 30 324,777 0.32 Jul-08 0.140 0.174 6,669,864 31 215,157 0.22 Aug-08 0.121 0.174 6,898,422 31 222,530 0.22 Sep-08 0.148 0.243 5,428,116 30 180,937 0.18 Oct-08 0.177 0.243 5,750,286 31 185,493 0.19 Nov-08 0.128 0.243 5,297,130 30 176,571 0.18 Dec-08 0.092 0.118 6,065,724 31 195,669 0.20 Jan-09 0.089 0.118 5,634,672 31 181,764 0.18 Feb-09 0.121 0.121 4,597,320 28 164,190 0.16 Mar-09 0.103 0.174 4,954,344 31 159,818 0.16 Apr-09 0.107 0.118 4,987,704 30 166,257 0.17 Note: The plant discharge includes: clarifier backwash, filter backwash and the 5 minute filter to waste at plant start-up. It does not include periodic filter wasting associated with treatment process. Highlighted data indicates months that we would not meet our proposed flow limit requirments. Mickey, Mike From: Mike Weir [mweir@yadtel.net] Sent: Friday, May 29, 2009 9:29 AM To: Sledge, Bob Cc: beth.dirks@co.davie.nc.us; jgrey@greyengineering.com; Mickey, Mike; raymond.lambert@co.davie.nc.us Subject: Draft NPDES Permit Comments Attachments: draftpermitreview.doc; avgflowcomparison.xls Good Morning Bob, I have reviewed our Draft NPDES permit and have made some comments on it to be reviewed. I acknowledge the changes to our permit and have a few concerns regarding the changes that I would like to address while it is still in the public comment stage. I have attatched a letter addressing our concerns as well as a small simple excel spreadsheet that illustrates some of our data pertaining to the flow limitation. If I need to submit via mail a hard copy please let me know so I can send it to the right address as soon as possible. Any questions or comments please feel free to contact me. Thanks, Michael C. Weir ORC. Sparks Rd. WTP Davie County Public Utilities Office: 336-998-9763 Cell: 336-477-5037 Fax: 336-998-2272 1 NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES FAX TRANSMITTAL Water Quality Section Winston-Salem Regional Office 585 Waughtown Street Winston-Salem, N.C. 27107 Phone: (336)771-5000 TO: FAX NUMBER: AAIFFMA, r4*4 )PVA �ENR Fax: (336)771-4630 FROM: ��V�L, ��t (mike.mickey@ncdenr. og_v) DATE: Number of pages (including cover page): CONIM[ENTS: A�. NCDENR North Carolina Department of Environment and Natural Resources Division of"Water Quality Beverly Eaves Perdue Coleen H. Sullins Governor Director May 6, 2009 Mr. Jeff Crisco, Director Davie County Public Utilities 261 Chaffin Street Mocksville, NC 27028 Subject: Dear Mr. Crisco: Draft NPDES Permit Permit Number NCO084212 Davie County — Sparks Road WTP Davie County K`/�— Dee Freeman Secretary RECEIVED N.C. Dept. of ENR MAY 0 7 20M Wipston-Salem Regional Office Enclosed with this letter is a copy of the draft permit for your facility. Please review the draft very carefully to ensure thorough understanding of the conditions and requirements it contains. The draft permit contains a number of changes in the monitoring requirements from those found in your current permit. These changes were made as part of the NPDES strategies for wastewater discharges from potable water treatment plants, which are being implemented throughout the state as permits are issued and/or renewed. Some of these changes are: • The facility has been given a flow limit based on the highest reported monthly average flow that occurred over the past three years. Flow monitoring has been changed to continuous, based upon the reported occurrence of discharge. The permit provides a one year compliance schedule to allow the facility time to purchase and install a suitable flow metering device. • Monitoring requirements for Settleable Solids and Turbidity have been removed from the permit. • Monitoring requirements for Calcium, Magnesium, Manganese, Fluoride, Copper, and pH have been added based upon, studies of discharges from conventional water treatment facilities. Please note the permit contains provision for reduction or removal of monitoring for particular parameters if it can be shown there is no reasonable potential for their presence in the effluent. • A monitoring requirement for Total Zinc has been added to the draft permit because the facility uses zinc orthophosphate as a corrosion inhibitor. • The monitoring frequency for Aluminum has been reduced to quarterly; monitoring for Total Iron has been reduced to monthly. 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 one Location: 512 N. Salisbury St. Raleigh, North Carolina 27604 NorthCarohna Phone: 919-807-M \ FAX: 919-807-6492 \ Customer Service:1-877-623-6748 Internet www.ncwaterquality.org NiatzmallffAn Equal Opportunity \ Affirmative Action Employer Mi. Jeff Crisco NCO084212 Renewal Draft p• 2 • Whole Effluent Toxicity monitoring has been added to the permit. Please note that while the result of the required test will be "pass" or "fail," at present this is a monitoring requirement only, with no associated compliance limit. • The facility -description has been updated to show the addition of dechlorination. facilities. • A footnote has been added regarding the reporting and compliance determination of Total Residual Chlorine values. Please submit any comments to me no later than thirty days following your receipt of the draft. Comments should be sent to the address listed at the bottom of this page. If no adverse comments are received from the public or from you, this permit will likely be issued in July 2009, with an effective date of August 1, 2009. If you have any questions or comments concerning this draft permit, call me at (919) 807-6398, or via e- mail at bob.sledge@ncdenr.gov. , Sincerely, Bob Sledge Point Source Branch cc: Central Files Winston-Salem Regional Office/Surface Water Protection Section . NPDES Files DE1VPWS/WSRO Permit NCO084212 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY PERMIT TO DISCHARGE WASTEWATER UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provisions of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Davie County Public Utilities is hereby authorized to discharge wastewater from a facility located at the Sparks Road WTP 728 Sparks Road, northeast of Farmington Davie County to receiving waters. designated as an unnamed tributary to the Yadkin River in the Yadkin -Pee Dee River Basin in accordance with effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III and IV hereof. This permit shall become effective This permit and authorization to discharge shall expire at midnight on May 31, 2014. Signed this day DRAFT Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit NC0084212 SUPPLEMENT TO PERMIT COVER SHEET All previous NPDES Permits issued to this facility, whether for operation or discharge are hereby revoked. As of this permit issuance, any previously issued permit bearing this number is no longer effective. Therefore, the exclusive authority to operate and discharge from this facility arises under the permit conditions, requirements, terms, and provisions included herein. Davie County Public Utilities is hereby authorized to: 1. Continue to operate an existing water treatment facility with the following components: ♦ Two filter backwash lagoons ♦ Dechlorination This facility is located at the Sparks Road WTP (728 Sparks Road) northeast of Farmington in Davie County. 2. Discharge from said treatment works at the location specified on the attached map into an unnamed tributary to the Yadkin River, currently classified WS-1V waters in the Yadkin -Pee Dee River Basin. y Permit NCO084212 A. (1) EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS During the period beginning on the effective date of this permit and lasting until expiration, the Permittee is authorized to discharge from outfall 001. Such discharges shall be limited and monitored by the Permittee as specified below: k Flow 0.023 MGD Continuousl Effluent Total Suspended Solids 30.0 mg/L 45.0 mg/L 2/Month Grab Effluent Total Residual Chlorine2 17pg/L 2/Month Grab Effluent pH3 2/Month Grab Effluent Aluminum Quarterly5 Grab Effluent Calcium4 Quarterlys Grab Effluent Magnesium4 Quarterly5 Grab Effluent Manganese4 Quarterly5 Grab Effluent Fluoride Monthly Grab Effluent Total Zinc Monthly Grab Effluent Total Copper Monthly Grab Effluent Total Iron Monthly Grab Effluent Whole Effluent Toxicity6 Quarterly Grab Effluent Footnotes: 1. The requirement for continuous flow monitoring will become effective 12 months following the effective date of the permit. 2. The Division shall consider all effluent TRC values reported below 50 µg/L to be in compliance with the permit. However, the Permittee shall continue to record and submit all values reported by a North Carolina certified laboratory (including field certified), even if these values fall below 50 µme-- 3. The pH shall not be less than 6.0 standard units, nor greater than 9.0 standard units. 4. - After sufficient data have been collected (8 —12 data points over at least one year), the Permittee may request a review of reasonable potential for monitoring and effluent limitations. 5. Monitoring should be performed in conjunction with toxicity testing. 6. See Condition A. (2.) for toxicity testing requirements. Toxicity sampling should coincide with sampling for parameters covered by footnote 5. There shall be no floating solids or foam in other than trace amounts. Permit NCO084212 A. (2.) CHRONIC TOXICITY MONITORING (QUARTERLY) The permittee shall conduct uq arterly chronic toxicity tests using test procedures outlined in the "North Carolina Ceriodaphnia Chronic Effluent Bioassay Procedure," Revised February 1998, or subsequent versions. The effluent concentration defined as treatment two in the procedure document is 90 %. The testing shall be performed as a Ceriodaphnia dubia 7day pass/fail test. The tests will be performed during the months of February, May, August and November. Effluent sampling for this testing shall be performed at the NPDES permitted final effluent discharge below all treatment processes. All toxicity testing results required as part of this permit condition will be entered on the Effluent Discharge Monitoring Form (MR-1) for the month in which it was performed, using the parameter code TGP3B. Additionally, DWQ Form AT-1(original) is to be sent to the following address: Attention: NC DENR / DWQ /Environmental Sciences Section 1621 Mail Service Center Raleigh, N.C. 27699-1621 Completed Aquatic Toxicity Test Forms shall be filed with the Environmental Sciences Section no later than 30 days after the end of the reporting period for which the report is made. Test data shall be complete and accurate and include all supporting chemical/physical measurements performed in association with the toxicity tests, as well as all dose/response data. Total residual chlorine of the effluent toxicity sample must be measured and reported if chlorine is employed for disinfection of the waste stream. Should there be no discharge of flow from the facility during a month in which toxicity monitoring is. required, the permittee will complete the information located at the top of the aquatic toxicity (AT) test form indicating the facility name, permit number, pipe number, county, and the month/year of the report with the notation of "No Flow" in the comment area of the form. The report shall be submitted to the Environmental Sciences Section at the address cited above. Should the permittee fail to monitor during a month in which toxicity monitoring is required, then monthly monitoring will begin immediately. Upon submission of a valid test, this monthly test requirement will revert to quarterly in the months specified above. Should any test data from this monitoring requirement or tests performed by the North Carolina Division of Water Quality indicate potential impacts to the receiving stream, this permit may be re- opened and modified to include alternate monitoring requirements or limits. If the Permittee monitors any pollutant more frequently then required by this permit, the results of such monitoring shall be included in the calculation & reporting of the data submitted on the DMR & all AT Forms submitted. NOTE: Failure to achieve test conditions as specified in the cited document, such as minimum control organism survival, minimum control organism reproduction, and appropriate environmental controls, shall constitute an invalid test and will require immediate follow-up testing to be completed no later than the last day of the month following the month of the initial monitoring. Mickey, Mike From: Mickey, Mike Sent: Monday, May 11, 2009 11:19 AM To: Sledge, Bob Cc: 'Tedder, Steve' Subject: Draft Permit - Davie Co. WTP - NC0084212 Bob - Below are my comments on the above draft permit for the Sparks Road WTP: 1) The monthly average flow limit of 0.023 MGD is too low. Is this a decimal error? The cover letter states that the limit is based on the highest monthly average flow reported over the last three years. I pulled just the 2008 monitoring reports from our files and the highest month was 0.177 MGD in October 2008. 1 would suggest that the limit be set higher than any value they have reported to date. With anticipated growth in the county the WTP output will surely increase causing higher backwash flows than previously reported. Perhaps the NPDES flow limit could be based on maximum backwash flow at maximum WTP output so we don't create a noncompliance issue. 2) Suggest a grace period of 18 months instead of 12 months to have flow meter installed. Spoke with Mike Weir, ORC, on Friday and he indicated that they are working to find funds for an open channel flow meter with sonar attached to their SCADA system. 3) Recommend that footnote (4) also apply to Whole Effluent Toxicity testing. If the effluent does not exhibit toxicity then monitoring could be discontinued. Thanks, Mike. Please note new E-mail address: Mike. Mickev@NCDENR.eov Mike Mickey NC Division of Water Quality 585 Waughtown Street Winston-Salem, NC 27107 Phone: (336) 771-4962 FAX: (336) 771-4630 E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. Mickey, Mike From: Mike Weir [mweir@yadtel.net] Sent: Thursday, May 07, 2009 12:20 PM To: Mickey, Mike Subject: NPDES Permit Hey Mike, this is Michael Weir with Davie County Water, NPDES permit number NC0084212. I have a few questions about our NPDES permit draft that you had faxed me today. Wondering if you could maybe stop by or give me a ring at your convenience. Significant changes to say the least, the one that I have the most questions about and the biggest concern is the flow. I have already turned in my budget for next year and will have to add some funds to cover this addition to our facility very quickly. There is a few different ways we can achieve this and I wanted to run them by you or get a better feel for what the state is wanting or requiring for flow monitoring. Thanks, Michael C. Weir ORC. Sparks Rd. WTP Davie County Public Utilities Office: 336-998-9763 Cell: 336-477-5037 Fax: 336-998-2272 1 AJ A NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Governor Mr. Jeff Crisco, Director Davie County Public Utilities 261 Chaffin Street Mocksville, NC 27028 Subject: Dear Mr. Crisco: Coleen H. Sullins Director May 6, 2009 Draft NPDES Permit Permit Number NCO084212 Davie County — Sparks Road WTP Davie County Ali -- Dee Freeman Secretary RECEIVED N.C. Dent of ENR MAY 0 7 2009 { Winston-Salem, Regional Office Enclosed with this letter is a copy of the draft permit for your facility. Please review the draft very carefully to ensure thorough understanding of the conditions and requirements it contains. The draft permit contains a number of changes in the monitoring requirements from those found in your current permit. These changes were made as part of the NPDES strategies for wastewater discharges from potable water treatment plants, which are being implemented throughout the state as permits are issued and/or renewed. Some of these changes are: • The facility has been given a flow limit based on the highest reported monthly average flow that occurred over the past three years. Flow monitoring has been changed to continuous, based upon the reported occurrence of discharge. The permit provides a one year compliance schedule to allow the facility time to purchase and install a suitable flow metering device. • Monitoring requirements for Settleable Solids and Turbidity have been removed from the permit. • Monitoring requirements for Calcium, Magnesium, Manganese, Fluoride, Copper, and pH have been added based upon studies of discharges from conventional water treatment facilities. Please note the permit contains provision for reduction or removal of monitoring for particular parameters if it can be shown there is no reasonable potential for their presence in the effluent. • A monitoring requirement for Total Zinc has been added to the draft permit because the facility uses zinc orthophosphate as a corrosion inhibitor. • The monitoring frequency for Aluminum has been reduced to quarterly; monitoring for Total Iron has been reduced to monthly. 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 One Location: 512 N. Salisbury St. Raleigh, North Carolina 27604 NorthCarohna Phone: 919-807-6300 \ FAX: 919-807-6492 \ Customer Service:1-877-623-6748 Internet: www.ncwaterquality.org Naturally An Equal Opportunity\ Affirmative Action Employer Mr. Jeff Crisco NC0084212 Renewal Draft p. 2 Whole Effluent Toxicity monitoring has been added to the permit. Please note that while the result of the required test will be "pass" or "fail," at present this is a monitoring requirement only, with no associated compliance limit. • The facility description has been updated to show the addition of dechlorination facilities. A footnote has been added regarding the reporting and compliance determination of Total Residual Chlorine values. Please submit any comments to me no later than thirty days following your receipt of the draft. Comments should be sent to the address listed at the bottom of this page. If no adverse comments are received from the public or from you, this permit will likely be issued in July 2009, with an effective date of August 1, 2009. If you have any questions or comments concerning this draft permit, call me at (919) 807-6398, or via e- mail at bob.sledge@ncdenr.gov. Sincerely, J41, Bob Sledge Point Source Branch cc: Central Files Winston-Salem Regional Office/Surface Water Protection Section NPDES Files DEH/PWS/WSRO Permit NCO084212 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY PERMIT TO DISCHARGE WASTEWATER UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provisions of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Davie County Public Utilities is hereby authorized to discharge wastewater from a facility located at the Sparks Road WTP 728 Sparks Road, northeast of Farmington Davie County to receiving waters designated as an unnamed tributary to the Yadkin River in the Yadkin -Pee Dee River Basin in accordance with effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III and IV hereof. This permit shall become effective This permit and authorization to discharge shall expire at midnight on May 31, 2014. Signed this day DRAFT Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit NC0084212 SUPPLEMENT TO PERMIT COVER SHEET All previous NPDES Permits issued to this facility, whether for operation or discharge are hereby revoked. As of this permit issuance, any previously issued permit bearing this number is no longer effective. Therefore, the exclusive authority to operate and discharge from this facility arises under the permit conditions, requirements, terms, and provisions included herein. Davie County Public Utilities is hereby authorized to: 1. Continue to operate an existing water treatment facility with the following components: ♦ Two filter backwash lagoons ♦ Dechlorination This facility is located at the Sparks Road WTP (728 Sparks Road) northeast of Farmington in Davie County. 2. Discharge from said treatment works at the location specified on the attached map into an unnamed tributary to the Yadkin River, currently classified WS-IV waters in the Yadkin -Pee Dee River Basin. Latitude: 36°01'58" Longitude: 80P30'00" Quad # C16SE & C17SW Receiving Stream: UT Yadkin River Stream Class: WS-N Subbasin: 30702 NCO084212 County of Davie Sparks Road WTP Facility Location Odaqw North SCALE 1:24000 Permit NCO084212 A. (1) EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS During the period beginning on the effective date of this permit and lasting until expiration, the Permittee is authorized to discharge from outfall 001. Such discharges shall be limited and monitored by the Permittee as specified below: �yx 1 4 Neaem ; aot� ism ��H Sara c MYii Flow 0.023 MGD Continuous) Effluent Total Suspended Solids 30.0 mg/L 45.0 mg/L 2/Month Grab Effluent Total Residual Chlorine2 17 pg/L 2/Month Grab Effluent pH3 2/Month Grab Effluent Aluminum Quarterly5 Grab Effluent Calcium4 Quarterly5 Grab Effluent Magnesium4 Quarterly5 Grab Effluent Manganese4 Quarterly5 Grab Effluent Fluoride Monthly Grab Effluent Total Zinc Monthly Grab Effluent Total Copper Monthly Grab Effluent Total Iron Monthly Grab Effluent Whole Effluent Toxicitys I Quarterly Grab Effluent Footnotes: 1. The requirement for continuous flow monitoring will become effective 12 months following the effective date of the permit. 2. The Division shall consider all effluent TRC values reported below 50 µg/L to be in compliance with the permit. However, the Permittee shall continue to record and submit all values reported by a North Carolina certified laboratory (including field certified), even if these values fall below 50 n/L. 3. The pH shall not be less than 6.0 standard units, nor greater than 9.0 standard units. 4. After sufficient data have been collected (8 —12 data points over at least one year), the Permittee may request a review of reasonable potential for monitoring and effluent limitations. 5. Monitoring should be performed in conjunction with toxicity testing. 6. See Condition A. (2.) for toxicity testing requirements. Toxicity sampling should coincide with sampling for parameters covered by footnote 5. There shall be no floating solids or foam in other than trace amounts. Permit NC0084212 A. (2.) CHRONIC TOXICITY MONITORING (QUARTERLY) The permittee shall conduct quarterly chronic toxicity tests using test procedures outlined in the "North Carolina Ceriodaphnia Chronic Effluent Bioassay Procedure," Revised February 1998, or subsequent versions. The effluent concentration defined as treatment two in the procedure document is 90 %. The testing shall be performed as a Ceriodaphnia dubia 7day pass/fail test. The tests will be performed during the months of February, May, August and November. Effluent sampling for this testing shall be performed at the NPDES permitted final effluent discharge below all treatment processes. All toxicity testing results required as part of this permit condition will be entered on the Effluent Discharge Monitoring Form (MR-1) for the month in which it was performed, using the parameter code TGP3B. Additionally, DWQ Form AT-1 (original) is to be sent to the following address: Attention: NC DENR / DWQ / Environmental Sciences Section 1621 Mail Service Center Raleigh, N.C. 27699-1621 Completed Aquatic Toxicity Test Forms shall be filed with the Environmental Sciences Section no later than 30 days after the end of the reporting period for which the report is made. Test data shall be complete and accurate and include all supporting chemical/physical measurements performed in association with the toxicity tests, as well as all dose/response data. Total residual chlorine of the effluent toxicity sample must be measured and reported if chlorine is employed for disinfection of the waste stream. Should there be no discharge of flow from the facility during a month in which toxicity monitoring is required, the permittee will complete the information located at the top of the aquatic toxicity (AT) test form indicating the facility name, permit number, pipe number, county, and the month/year of the report with the notation of "No Flow" in the comment area of the form. The report shall be submitted to the Environmental Sciences Section at the address cited above. Should the permittee fail to monitor during a month in which toxicity monitoring is required, then monthly monitoring will begin immediately. Upon submission of a valid test, this monthly test requirement will revert to quarterly in the months specified above. Should any test data from this monitoring requirement or tests performed by the North Carolina Division of Water Quality indicate potential impacts to the receiving stream, this permit may be re- opened and modified to include alternate monitoring requirements or limits. If the Permittee monitors any pollutant more frequently then required by this permit, the results of such monitoring shall be included in the calculation & reporting of the data submitted on the DMR & all AT Forms submitted. NOTE: Failure to achieve test conditions as specified in the cited document, such as minimum control organism survival, minimum control organism reproduction, and appropriate environmental controls, shall constitute an invalid test and will require immediate follow-up testing to be completed no later than the last day of the month following the month of the initial monitoring. January 23, 2009 System Performance Annual Report DWQ 1617 Mail Service Center Raleigh, NC 27699-1617 Subject: 2008 System Performance Annual Report To Whom It May Concern: RECEIVED N.C. Dept. of ENR JAN 2 9 20Qg Win "stop; -Salem Regional Office In 2008 our facility showed exceptional performance in meeting all laws, regulations and rules pertaining to water quality. Our current NPDES permit # NCO084212 became effective 8/1/2004 and expires on 5/31/2009. We are currently seeking renewal of our NPDES permit and are awaiting response from the DWQ. The NPDES permit is issued to Davie County at the Sparks Road Water Treatment Plant and covers the operation of two parallel 785,000 gallon filter backwash lagoons. During 2008, Davie County had no violations and we met all or monitoring data and sampling requirements for the year. A chart of our 2008 annual averages for our monitoring data is found below. 2008 Annual Average Daily Flow .129 MGD TSS 1.54 mg/I Settable Solids 0 ml/I Iron .543 mg/I Total Residual C12 5.31 ug/I Upstream Turb. 2.30 NTU Downstream Turb. 2.96 NTU J A N 2 6 2009 DENR - WATER QUALITY POINT SOURCE BRANCH We are excited to bring this 2008 system performance report to you and look forward to making 2009 a even better year in the performance of our system. Sincerely, Mic C Weir ORC Sparks Rd. WTP Davie County, NC