Loading...
HomeMy WebLinkAboutWQ0041754_Application (FTSE)_20200612State of North Carolina DWR Department of Environmental Quality �� Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: (to be completed by owe) All items must be completed or the application will be returned 1. APPLICANT INFORMATION: 1. Applicant's name: K V Grandover Village. LLC (company, municipality, HOA, utility, etc.) 2. Applicant type: ® Individual ❑ Corporation ® General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ❑ Municipal ❑ Other 3. Signature authority's name: Richard Vanore per I SA NCAC 02T .0106(b) R C Dapartment of Title: Vice President Environmental Quality 4. Applicant's mailing address: 2275 Vanstory Street, Suite 200 Received _ City: Greensboro State: NC Zip: 27403-_ JUN 12 2020 5. Applicant's contact information: Winston-Salem Phone number: (336) 299-9200 Email Address: rvanoreakourycorp.com Regional Office 11. PROJECT INFORMATION: I. Project name: Grandover Village Phase 2 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: W000_ and issued date: If new construction but part of a master plan, provide the existing permit number: W000 3. County where project is located: Guilford 4. Approximate Coordinates (Decimal Degrees): Latitude: 36.002209' Longitude:-79.905061° 5. Parcel ID (if applicable): 0226572 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: I. Professional Engineer: Anthony D. Lester License Number: 19773 Firm: Evans En ig neering Inc. Mailing address: 4609 Dundas drive City: Greensboro State: NC Zip: 27407-_ Phone number: (336) 279-7450 Email Address: adl@evans-eng.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: East Side WWTF Permit Number: NCO024210 Owner Name: City of High Point V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): W00038683 Downstream (Receiving) Sewer Size: 8 inch System Wide Collection System Permit Number(s) (if applicable): WQCS00314 Owner Name(s): Town of Jamestown FORM: FTA 04-16 Pagel of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEVI been attached? ❑ Yes ❑No ®N/A 3. If the Applicant is a Home/Property Owners' Association, has an Operational Agreement (FORM: HOA) been attached? ❑ Yes ❑No ®N/A 4. Origin of wastewater: (check all that apply): ❑ Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ® Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: % Domestic/Commercial 100 % Commercial Industrial (See 15A NCAC 02T .0103(20)) "Is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Hasa flow reduction been approved under 15A NCAC 02T .0114(f)? ❑ Yes ®No ➢ If yes, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(fl) Daily Design Flow a•" No. of Units Flow 20,400 SF Retail 130 gal/1000 SF 20.4 2,652 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 2,652 GPD a See I5A NCAC 02T .0114(b), (d), (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east ofthe Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 0 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ® Flow has already been allocated in Permit Number: W00038683 ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: ETA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8" 580 DIP ➢ Section I1 & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: 0Longitude: - ° 3. Design flow of the pump station: _ millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): _ gallons per minute at _ feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B). ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(t)): 1. Does the project comply with all separations found in 15A NCAC 02T.0305(f) & N) ® Yes [-]No ➢ 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 24 inches Water mains (vertical -water over sewer including in benched trenches) 18 inches Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines horizontal - reclaimed over sewer 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class 11 impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade vertical 36 inches ➢ 15A NCAC 02T.0305(e) contains alternatives where separations in 02T.0305(f) cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications webpaee ➢ If noncompliance with 02T.0305(f) or (g). see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ❑ Yes ❑ No ® N/A ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑ Yes ❑ No ® N/A ➢ This would include Trout Buffered Streams per 15A NCAC 213.0202 4. Does the project require coverage/authorization under a 404 Nationwide or ❑ Yes ® No individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401 & Buffer Permittin Branch ranch 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ®No ❑ N/A ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? 10/�Mlm If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineer's Certification: I, ANTrtDN Y D • le sTfR attest that this application for (Professional Engineer's name from Application Item III.1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signatu e, and date: 0``0 S k CAR �Q ESSl ��CQQ-pE ONE j = SEAL = 19773 ;_ 3-18•� 3. Applicant's Certification per 15A NCAC 02T .01 91 �.lu.�•p� V,a►�lbp�, p(Z�SInP�—G( attest (Signature Authority's name & title from Application Item I.3.) J- that this application for has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: 777 Date: FORM: FTA 04-16 Page 5 of 5 I valns ngineering, Inca —Since 1974— 1 Engineers Surveyors Planners June 12, 2020 NC Department of Environmental Quality Received Justin Henderson Environmental Senior Specialist JUN 12 2020 Winston Salem Regional Office Winston-Salem Division of Water Resources Regional Office 450 W. Hanes Mill Road Winston Salem, NC 27105 Re: Fast Track Sanitary Sewer Application for Grandover Village Phase II Justin, Please find attached the completed application package and the $480 fee check. The flow for this project was permitted in a previously approved permit (WQ0038683). Paul Blanchard, Public Services Director for the Town of Jamestown, submitted this application (a couple years ago). Please review and process for approval. Let me know if you have any questions. Sincerely, Anthony D. Le t r, PE, PLS Vice President Evans Engineering, Inc. M/Tony/630.266 Fast Track Sanitary Sewer Application VR 011 - WN tlivlsinr of Water ttrsone'ece State of North Carolina Department of > avh•onnicatal Qaality Division of Water Resoat•ces Flow Tracking for Server Extension Applications (FTSE 10-18) Application Number: 2020;I49 Entity Requesting Allocation: KV Grandover Village, LLC Project Name for which flow is being requested: Grandover Village Phase 2 More Men one FTSR may be required for a single project ifthe oipner efthe WIM is not responsible for oll penip stations along the ronte oflhe proposed wasten alerfloip. 1. Complete this section only if you are the owner of the wastewater heahnent plant. a. WWTP Facility name: EastsideWWTP b. W WTP Facility Permit #: NC-0024210 `:: All flmve are !n MC:D c. WWTP facility permitted flow: 26.0000 it. Militated obligated flow not yet tributary to the WWTP: 0.7709 e. W WTP facility's actual average flow: 16.3917 £ Total flow for this specifro request: 0.0027 g. Total actual and obligated flows to the facility: 17.1652 h. Percent of permitted flow used: 66.02% 11. Complete (his section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the W WTP. (A) (m) (C) (D)-(a+C) (E}--(A-D) Pump pmnp Fiml Design Approx. Obligated, Total Curren Available station station Capacity Average Cunent Not Yet Flow Plus Capacity' (Name or Pemdl Daily Flows Avg. Wily tributary Obligated Number) Number (Finn/po, Flow, Delly Flow, flow AM A1GD Mon MGD AIGD Mine atrndala WQMS72 30.067 IIA$42 8.1996 OM14 9.1310 2Jan -• aWA MIA AWA MIA MIA IWA AN/A AWA AWA AWA 9WA AWA AWA AWA IWA AWA MIA AWA MIA AWA AWA IWA AMA • The Fh•m Capaelty(design aov) ofmlypump 1Iai on Is defined ns d e maximum pmnped Dow Met can he nchleved whit Ike largest pump Inken out ofservieo, Design Average Flow Is the alma capacity of Ilse pump Mellon divided by the penldog factor (pq not less Than 2.5, per Section 2.02(A)(4)(e) of the Minhnuns Design Criteria. AAa A Planning ADtssmenl Addendum shall bo glinched for•ench pump slanun lacnied hehveen Ilia project connection point and the WWTP where the Avnilable Capaelty 1990. Downstream Facility Name (Sower): Downstream Permit Number: AWA AWA ARIA AWA MIA MIA ARIA MIA Page 1 of 0 FfS210.1 a III. Certification Statement 1, Terry Houk certify to the best of my knowledge that the addition of the volume of wastewater to be permitted hr this project has been evaluated along the route to the receiving wastewater treatment facility nod flint the flow from this project is not anticipated to cause any capacity related sanitary sower overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned Improvements Identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available date. This certification applies to those Reins listed above In Sections I and II plus all attached planning assessment addendums for which I mn the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed now wastewater. Signing O,/JJc SS"nal'rle 1?ub1kC. Se-X/ecC� i7/�7dh Title of Signing Official Date 6/1 I/2020 Pane 2 of 0 FTSE 10.1a Public Services Department Terry L. Houk DIRECTOR NORTH CAROLINNS INTERNATIONAL CITr June 11, 2020 NCDENR Winston-Salem Regional Office 450 W. Hanes Mill Rd, Suite 300 Winston-Salem, NC 27105 Project: Grandover Village Phase 2 Applicant: KV Grandover Village, LLC Dear Sir or Madam, This is to acknowledge that the City of High Point will accept for treatment in the Eastside Wastewater Treatment Plant (Permit #NC0024210), wastewater flow from the above referenced project in the amount of 2,652 GPD. This flow will be discharged to facilities operated and maintained by Jamestown and then to the City of High Point sanitary sewer system. If further information is needed, please let me know. Very truly yours, /t A�� Terry L. I3 ik Director of Public Services TLH/tab City of High Point, P.O. Box 230, 211 South Hamilton Street, High Point, NC 27261 USA Fax:336.883.1675 Phone:336.883.3215 TDD:336.883.8517 State of North Carolina Dft,� R Division of Water Resources Department of Environmental Quality Division of Water Resources Flow Tracking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: K V Grandover Village, LLC Project Name for which flow is being requested: Grandover Village Phase 2 More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name East Side WWTF b. WWTP Facility Permit #: NCO024210 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used All flows are in MGD 0.002652 Il. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Pump Average Approx. Not Yet Total Current Station Station Firm Daily Flow** Current Tributary Flow Plus (Name or Permit Capacity, * (Firm / pf), Avg. Daily Daily Flow, Obligated Available Number) No. MGD MGD Flow, MGD MGD Flow Capacity*** * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped now that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the Firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Grandover West Downstream Permit Number: W00038683 Page 1 of 6 FTSE 10-18 III. Certification Statement: I Paul R. Blanchard certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. -PaL R. r?4J4 S? 4/3o/z,- . Signing Official Signature Date F061ic Se -vices Dirnc.A-vy- Title of Signing Official Page 2 of 6 FTSE 10-18 10 cSellled 17,52 ANAMESTOWN ORTH CAROLINA April 30, 2020 Mr. Terry L. Houk City of High Point P.O. Box 230 High Point, NC 27261 RE: K V Grandover Village, LLC Grandover Village Parkway/Gate City Blvd Jamestown, North Carolina Dear Terry, The Town of )amestown requests a FT/SE for the K V Grandover Village, LLC site in )amestown. The flow from this project is part of the allocation from the previously permitted Grandover West project. It was approved under permit WQ0038683. This site is tributary to the gravity section of the Grandover West project, so it does not flow through any Town of Jamestown pump stations. The flow from this project is 2,652 gpd per the application. The permitted versus allocated flows for the overall project are summarized below: Grandover West Project Permitted Flow: 1 12,680 gpd Millis &Main Apartments Allocated Flow: 43,200 gpd Millis and Main Phase II Apts Allocated Flow: 34,900 gpd Publix Allocated Flow: 6,500 gpd K V Grandover West, LLC Design Flow: 2.652 gpd Balance of Flow Not Allocated: 25,428 gpd I hope this will help with the bookkeeping of the flows as the project develops. I am enclosing scanned copies of the permit, required forms, and the Jamestown FT/SE. Please feel free to contact me with any questions regarding this project. Respectfully, Paul R. Blanchard, PE Public Services Director C: Anthony D. Lester, Evans Engineering, Inc. file P.O. Box 848 Jamestown, NC 27282 www.jamestown-nc.gov Tel:(336)454-1138 Fax:(336)886-3504