Loading...
HomeMy WebLinkAbout20200799 Ver 1_401 Application_20200616DWR mrlslon of Water Resources Pre -Construction Notification (PCN) Form April 11, 2020 Ver 3.1 Initial Review Has this project met the requirements for acceptance in to the review process?* r Yes r No Is this project a public transportation project?* C Yes r No Change only if needed. BIMS # Assigned 20200799 Is a payment required for this project?* r No payment required r Fee received r Fee needed - send electronic notification Select Project Reviewer* Stephanie Goss:eads\szgoss Information for Initial Review la. Name of project: COURTESY COPY - Fifth Street Landing BAA Renovation 1a. Who is the Primary Contact?* Michael Leggett 1b. Primary Contact Email:* michael.leggett@ncWldlife.org Date Submitted 6/16/2020 Nearest Body of Water Roanoke Rapids Lake Basin Roanoke Water Classification WS-N, B;CA Site Coordinates Latitude: Longitude: 36.473594-77.678227 A. Processing Information County (or Counties) where the project is located: Halifax Is this a NCDMS Project r Yes r No Is this project a public transportation project?* r Yes r No la. Type(s) of approval sought from the Corps: W Section 404 Permit (wetlands, streams and waters, Clean Water Act) r Section 10 Permit (navigable waters, tidal waters, Rivers and Harbors Act) Version#* 1 Reviewing Office* Raleigh Regional Office - (919) 791-4200 1c. Primary Contact Phone:* (919)707-0083 V 1b. What type(s) of permit(s) do you wish to seek authorization? r Nationwide Permit (NWP) W Regional General Permit (RGP) r Standard (IP) 1c. Has the NWP or GP number been verified by the Corps? r Yes r No Regional General Permit (RGP) Number: RGP Numbers (for multiple RGPS): 1d. Type(s) of approval sought from the DWR: W 401 Water Quality Certification - Regular r Non-404 Jurisdictional General Permit r Individual Permit 198200030 - Work in Waters of Lakes and Reservoirs le. Is this notification solely for the record because written approval is not required? For the record only for DWR 401 Certification: For the record only for Corps Permit: F- 401 Water Quality Certification - E)press r Riparian Buffer Authorization 1f. Is this an after -the -fact permit application?* r Yes r No 1g. Is payment into a mitigation bank or in -lieu fee program proposed for mitigation of impacts? r Yes r No 1g. Is payment into a mitigation bank or in -lieu fee program proposed for mitigation of impacts? r Yes r No Acceptance Letter Attachment 1h. Is the project located in any of NC's twenty coastal counties? r Yes r No 1j. Is the project located in a designated trout watershed? r Yes r No B. Applicant Information 1d. Who is applying for the permit? r Owner W Applicant (other than owner) le. Is there an Agent/Consultant for this project?* r Yes r No 2. Owner Information 2a. Name(s) on recorded deed: Dominion Energy 2b. Deed book and page no.: N/A 2c. Responsible party: North Carolina Wildlife Resources Commission 2d.Address Street Address 1720 MSC Address Line 2 city Raleigh Postal / Zip Code 27699 2e. Telephone Number: (919)707-0083 2g. Email Address:* michael.leggett@ncWldlife.org State / Rwince / Ifgion NC Country USA 2f. Fax Number: r Yes r No r Yes r No 3. Applicant Information (if different from owner) 3a. Name: Michael Leggett 3b. Business Name: North Carolina Wildlife Resources Commission 3c.Address Street Address 1720 MSC Address Line 2 (Sty State / Province / F bgion Raleigh NC Postal / Zip Code Country 27699 US 3d. Telephone Number: 3e. Fax Number: (919)707-0083 3f. Email Address:* michael.leggett@nGvAidlife.org C. Project Information and Prior Project History 1. Project Information 1b. Subdivision name: (d appropriate) 1c. Nearest municipality/ town: Roanoke Rapids 2. Project Identification 2a. Property Identification Number: Unknown 2c. Project Address Street Address 1919 W. Fifth Street Address Line 2 city Roanoke Rapids Postal / Zip Code 27870 3. Surface Waters 3a. Name of the nearest body of water to proposed project:* Roanoke Rapids Lake 3b. Water Resources Classification of nearest receiving water:* WS-N, B;CA 3c. What river basin(s) is your project located in?* Roanoke 3d. Please provide the 12-digit HUC in which the project is located. 030101060404 4. Project Description and History 2b. Property size: Unknown State / Province / legion NC Country 4a. Describe the existing conditions on the site and the general land use in the vicinity of the project at the time of this application:* The existing Fifth Street Landing Boat Access Area is located on Roanoke Rapids Lake and has been in operation for over 30 years. The area is used primarly for recreation, and includes the boat ramp, ADA parking, and paved parking for patrons of the boat ramp. The existing concrete ramps, tongue and groove groins, and fixed docks have reached the end of their life cycle and are in need of replacement. NCWRC is proposing demolition of the existing structures and replacement with new concrete ramps, newgroins, and one (1) new floating dock separating the concrete ramp bays. 4b. Have Corps permits or DWR certifications been obtained for this project (including all prior phases) in the past?* r Yes r No r Unknown 4d. Attach an 8 1/2 X 11 excerpt from the most recent version of the USGS topographic map indicating the location of the project site. (for DWR) 4e. Attach an 8 1/2 X 11 excerpt from the most recent version of the published County NRCS Soil Survey map depicting the project site. (for DWR) 4f. List the total estimated acreage of all existing wetlands on the property: 0 4g. List the total estimated linear feet of all existing streams on the property: 0 4h. Explain the purpose of the proposed project:* The eAsting concrete ramps, tongue and groove groins, and fixed docks have reached the end of their life cycle and are in need of replacement. NCWRC is proposing demolition of the wasting structures and replacement with new concrete ramps, new groins, and one (1) newfloating dock separating the concrete ramp bays. This Will allowcontinued usage of the site and provide a safer facility for the general public. 41. Describe the overall project in detail, including indirect impacts and the type of equipment to be used:* NCWRC is proposing demolition of the epsting structures and replacement with new concrete ramps, new groins, and one (1) newfloating dock separating the concrete ramp bays. Each concrete ramp would be approArnately 16' in width with approArnately 15' of usable space for off loading watercraft. A concrete abutment would be installed in between each ramp for the floating dock. Two newsheet pile groins will be installed on both sides of the ramp. All work will take place in the existing ramp footprint. Equipment will consist of excavators, bulldozers, and dump trucks. The ramp area will be closed during construction so indirect impacts will be at a minimum. 4j. Please upload project drawings for the proposed project. 5. Jurisdictional Determinations 5a. Have the wetlands or streams been delineated on the property or proposed impact areas?* r Yes r No Comments: No work will takeplace outside the epsting footprint of the ramp 5b. If the Corps made a jurisdictional determination, what type of determination was made?* r Preliminary r Approved r Not Verified r Unknown F N/A Corps AID Number: 5c. If 5a is yes, who delineated the jurisdictional areas? Name (if known): Agency/Consultant Company: Other: 5d1. Jurisdictional determination upload 6. Future Project Plans 6a. Is this a phased project?* r Yes R No O Unknown Are any other NWP(s), regional general permit(s), or individual permits(s) used, or intended to be used, to authorize any part of the proposed project or related activity? D. Proposed Impacts Inventory 1. Impacts Summary 1a. Where are the impacts associated with your project? (check all that apply): r Wetlands r Streams -tributaries W Open Waters r Pond Construction 4.Open Water Impacts F Buffers 4a. Site # 4a1. Impact Reason 4b. Impact type 4c. Name of waterbody 4d. Activity type 4e. Waterbody type 4f. Impact area Ramp Demo /Construction P Roanoke Rapids Lake Dock &Pier _11 Lake 0.09 4g. Total temporary open water Impacts: 0.00 4g. Total open water impacts: 0.09 4h. Comments: Work will take place within existing boat ramp area footprint. E. Impact Justification and Mitigation 4g. Total permanent open water impacts: 0.09 V v 1. Avoidance and Minimization 1a. Specifically describe measures taken to avoid or minimize the proposed impacts in designing the project: All work is to take place withing the existing boat ramp footprint. No work is expected outside of this area. 1b. Specifically describe measures taken to avoid or minimize the proposed impacts through construction techniques: Traditional ramp construction techniques will be utilized. No live concrete will come in contact with water. 2. Compensatory Mitigation for Impacts to Waters of the U.S. or Waters of the State 2a. Does the project require Compensatory Mitigation for impacts to Waters of the U.S. or Waters of the State? r Yes r No 2b. If this project DOES NOT require Compensatory Mitigation, explain why: Work will take place within the existing footprint of the ramp. No additional impacts are expected. =Stormwater Management and Diffuse Flow Plan (required by DWR) 1. Diffuse Flow Plan 1a. Does the project include or is it adjacent to protected riparian buffers identified within one of the NC Riparian Buffer Protection Rules? r Yes r No If no, explain why: Project is not within a riparian buffer area. The proposed apron area (at top of ramp) will be graded to diffuse water to either side of the ramp (to existing ditch and existing grassed area). 2. Stormwater Management Plan 2a. Is this a NCDOT project subject to compliance with NCDOT's Individual NPDES permit NCS000250?* r Yes r No 2b. Does this project meet the requirements for low density projects as defined in 15A NCAC 02H .1003(2)? r Yes r No Comments: G. Supplementary Information 1. Environmental Documentation 1a. Does the project involve an expenditure of public (federal/state/local) funds or the use of public (federal/state) land?* r Yes r No 1b. If you answered "yes" to the above, does the project require preparation of an environmental document pursuant to the requirements of the National or State (North Carolina) Environmental Policy Act (NEPAUSEPA)?* r Yes r No Comments:* Project does not meet thresholds of NEPA/SEPA. 2. Violations (DWR Requirement) 2a. Is the site in violation of DWR Water Quality Certification Rules (15ANCAC 2H .0500), Isolated Wetland Rules (15A NCAC 2H .1300), or DWR Surface Water or Wetland Standards or Riparian Buffer Rules (15A NCAC 2B .0200)? * r Yes r No 3. Cumulative Impacts (DWR Requirement) 3a. Will this project result in additional development, which could impact nearby downstream water quality?* r Yes r No 3b. If you answered "no," provide a short narrative description. Public ramp with no development potential onsite. 4. Sewage Disposal (DWR Requirement) 4a. Is sewage disposal required by DWR for this project?* rYes r Nor WA 5. Endangered Species and Designated Critical Habitat (Corps Requirement) 5a. Will this project occur in or near an area with federally protected species or habitat?* r- Yes r No 5b. Have you checked with the USFWS concerning Endangered Species Act impacts?* r Yes r No 5c. If yes, indicate the USFWS Field Office you have contacted. Raleigh 5d. Is another Federal agency involved?* r Yes r No 5e. Is this a DOT project located within Division's 1-8? r Yes r No 5f. Will you cut any trees in order to conduct the work in waters of the U.S.? r Yes r No 5g. Does this project involve bridge maintenance or removal? r Yes r No 5h. Does this project involve the construction/installation of a wind turbine(s)?* r Yes r No r Unknown Si. Does this project involve (1) blasting, and/or (2) other percussive activities that will be conducted by machines, such as jackhammers, mechanized pile drivers, etc.? r Yes r No If yes, please provide details to include type of percussive activity, purpose, duration, and specific location of this activity on the property. Pile Work.pdf 7.18KB 5j. What data sources did you use to determine whether your site would impact Endangered Species or Designated Critical Habitat? USF&W service IPaC website. Hardoopy submitted to Raleigh office. Consultation Documentation Upload 6. Essential Fish Habitat (Corps Requirement) 6a. Will this project occur in or near an area designated as an Essential Fish Habitat?* r- Yes f• No 6b. What data sources did you use to determine whether your site would impact an Essential Fish Habitat?* NOAA EFH Mapper 7. Historic or Prehistoric Cultural Resources (Corps Requirement) 7a. Will this project occur in or near an area that the state, federal or tribal governments have designated as having historic or cultural preservation status?* r Yes r No 7b. What data sources did you use to determine whether your site would impact historic or archeological resources?* NCSHPO Historic Properties Map. A submittal was made to NCSHPO requesting comment. 7c. Historic or Prehistoric Information Upload 8. Flood Zone Designation (Corps Requirement) 8a. Will this project occur in a FEMA-designated 100-year floodplain?* r Yes r No 8b. If yes, explain how project meets FEMA requirements: Floodplain development permits will be obtained from appropriate authorities. 8c. What source(s) did you use to make the floodplain determination?* NCFRIS Miscellaneous Comments See attached construction plans and PCN exhibit. Dominion Energy has given preliminary approval and has concurred that plans meet their shoreline management plan. Per the shoreline management plan, no work will take place between March - June due to potential fish spawning. Miscellaneous attachments not previously requested. Fifth Street Plan Set.pdf 2.67MB Fifth Street PCN Exhibit.pdf 358.96KB Signature U R By checking the box and signing below, I certify that: • I have given true, accurate, and complete information on this form; I agree that submission of this PCN form is a "transaction" subject to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act'); • I agree to conduct this transaction by electronic means pursuant to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act'); • I understand that an electronic signature has the same legal effect and can be enforced in the same way as a written signature; AND • I intend to electronically sign and submit the PCN form. Full Name: Michael Leggett Signature Date 6/16/2020 Work will involve the embedment of forth (40) timber pilings and vinyl sheet pilings to replace the existing tongue and groove groins onsite. All pilings shall be vibrated or driven by means of a vibratory hammer and hydraulic or mechanical pile driver to the minimum depth in accordance with the plans. Work should be completed within 1 to 2 weeks, during business hours. I ' \ N PROP. GROIN IN FOOTPRINT OF EX. GROINLOO D — LC \ 1 1 0 I\ \ \ r 1 � r \ PRO CONC. P \ \ o � I / o 6' I J ct? \ \ o \ o f \LIMITS IMPAC S 0. I � / til BULKHEAD (TO REMAIN). I I I I I I N I I T EX. BULKHEAD J I T j PROP. SEAWALL CLOD — LOD —) LOD — L)— _ LC LOD —� LOD LOD s-- �ROP. G 0/N IN �pOT ll T / \ OF EW G 0/N / I PCN NOTES: ----- \'---------- I — I I I \ PROP. ADA SIDEWALK REPLACEMENT i (RE.- CD-8.2 I I STABILI E DISTURBED AREA / (RE. 1/CD-4.3) l✓, LOD — LOn SVJ i nn — 1-7 LOD --%K LOD / Z FLOODWAY BOUNDARY (PER MCTRIS) cV / / / 1. TOTAL DISTURBED AREA: 5,821 SF (0.13 ACRES) 2. TOTAL OPEN WATER IMPACTS: 4,000 SF (0.9 ACRES) J. CUT / FILL BELOW NWL: 27.85 CY (CUT) / 26.88 CY (FILL) 4. PROJECT SITE LOCATED IN ZONE AE (FLOODPLAIN) AND ZONE AE (FLOODWAY) PER NCFRIS (PANEL 3989, MAP # 3720398900K, DATE 0210412009). I I DO H@U U31E I i I�OG3 C�OMn �4G3MC�400Mn I / o I ' I I � fn I � 0 U N 30 I � = U I W� EX. PAVED W N MANEUVER AREA LL o w z 0 Z z J I J W w0 W <W azW U ll�(NO 'zzw 0o rn I I Q0ofof-o Uz-2 rnrn I F0 Ld o� 1 W 5�q� -c 16 I 33•10PROP. SMOOTH z o a iTRANSITION TO I I EX. PAVEMENT a w2 � N K y z U W I W I � I I Y 33 00 0 --- STABILIZE DISTURBED AREA WITH CLASS B RIP RAP Z Q m O W FZVOf�LAfflF-89 AOOI Y (PER CFRIS) 10 0 10 20 Scale 1" = 10' 05128120 File Name: FlF7HSTREET.dwg Surveyed: DC Designed: MM Drawn: MM CD-J. 0 NORTH CAROLINA WILDLIFE RESOURCES COMMISSION SHEET INDEX CD-0.0 COVER CD- 1.0 EXISTING CONDITIONS AND DEMOLITION CD-2.0 SITELAYOUT CD-2.1 SITE LAYOUT - MARINE WORK CD-3.0 GRADING PLAN CD-4.3 E& SC DETAILS CD-6.0 RAMP PROFILE CD-6.1 RAMP PROFILE CD-8.0 DETAILS CD-8.1 DETAILS CD-8.2 DETAILS CD-8.3 DETAILS LEGEND EX. CONTOUR (MJR) EX. CONTOUR (MNR) EX. EOP PROP. CONTOUR (MNR) PROP. CONTOUR (MJR) FLOOD PLAINT FLOODWAY WATER LEVEL EXISTING TREE LINE PROP. SPOT ELEV. DIVISION OF ENGINEERING SERVICES 1720 MAIL SERVICE CENTER RALEIGH, NORTH CAROLINA 27699-1720 (919) 707-0150 FAX. • (919) 707-0162 PROJECT FIFTH STREET LANDING -BOATING ACCESS AREA NWL NWL NWL NWL- x U2.00 RENO VA TION 1919 W. FIFTHS TREET ROANOKE RAPIDS, NC 27871 HALIFAX COUNTY, NC 36 0 28' 24"/ 770 40' 41 " SCO # 20 22182-01 SCO REVIEW SET 0611 1izozo M MW U31E PM WH372MMIN] T SITE PROJECT INFORMATION: SITE NAME.- DISTURBED AREA: FIFTH STREET LANDING BAA / RENOVATION 5,821 SF (0.13 ACRES) I FLOODWAY BOUNDARY (PER NCFRIS) I I AD (TO REMAIN) FLOODPLAIN BOUNDARY (PER NCFRIS) �I I EX. SIDEWALK (APPROX. 30 SF TO BE REMOVED) PMUNHI°- Qf DO H@U MSC IPO13 @@H3 G30C�40OM z O O U N W U tY N �W OU rn WW X W N LL0Ujz 0 Z z J J W U WU < aZ zo— J z > oWww a0UJ Uz U z J = �T)0 W ; C, J z 0 0 K �Q U 0 O �� 00 - �1-: o 00 ai ai -0 rn rn � U N � C U X d LL SITE NOTES: V Date: 06111120 1. ALL WORK TO BE PERFORMED WITHIN EXISTING BOAT RAMP FOOTPRINT File Name 2. ALL DEBRIS TO BE REMOVED OFFSITE AND DEPOSED OF IN ACCORDANCE WITH STATE AND FEDERAL REGULATIONS. FIFTHSTREET.dwg J. SITE OWNED BY DOMINION ENERGY WITH LEASE HELD BY NCWRC. 0 0 10 20 Surveyed: DC Designed: MM 4. TOPOGRAPHIC INFORMATION BASED ON TOPOGRAPHIC SURVEY PROVIDED BY NCWRC STAFF. Drawn MM Approved: 5. NO GEOTECHICAL EVALUATION, UTILITIES LOCATION OR BOUNDARY SURVEY PERFORMED ONSITE. Scale 1" = 10' Sheet No. 6. PROJECT SITE LOCATED IN ZONE AE (FLOODPLAIN) AND ZONE AE (FLOODWAY) PER NCFRIS (PANEL 3989, MAP #372O39890OK, DATE 0210412009). CD-I.o —— EX. T&G BULKHEAD L - - - - - - - - — — — — — — — — — I I (TO REMAIN) I I I I I I I j PROP. ADA SIDEWALK REPLACEMENT (RE: CD-8.2) TIE PROP. SEAWALL TO EX. BULKHEAD PROP. VINYL SHEETPILE GROIN (RE: 1/0-6.1 & CD-8.0) 77.15' �. ° MAX J.75' J �. 78.29' 20'. - PROP. CONC. RAMP ° D PROP. FLOATING DOCK (RE: CD-6.0/CO-6.1) d D I ° 1/CD-6.1) ° �°(RE. D d Z ° D �. ° D ° D . ��-8' �---I ° IN D ° IN D 6' 8 ° D ° n ° D ° IN Q D ° D ° Z IN ° ROP. BOLLARDS IN IN D PROP. ABUTMENT 16, D (RE: 1/CD-6.1 & CD-8.3) D. D ° z p� ° IN ° IN �. ° I ° D D°. Q ° MAX 7.5' PROP. VINYL SHEETPILE GROIN (RE: 1/0-6.1 & CD-8.0) 77.15' EX. TREELINE SITE NOTES: 1. NO UTILITIES HAVEN BEEN LOCATED. CONTACT 811 PRIOR TO WORK COMMENCING. 2. ALL WORK TO TAKE PLACE WITHIN EXISTING RAMP FOOTPRINT. J. SITE OWNED BY DOMINION ENERGY WITH LEASE HELD BY NCWRC. 4. TOPOGRAPHIC INFORMATION BASED ON TOPOGRAPHIC SURVEY PROVIDED BY NCWRC STAFF. 5. NO GEOTECHICAL DEVALUATION, UTILITIES LOCATION OR BOUNDARY SURVEY PERFORMED ONSITE. 6. PROJECT SITE LOCATED IN ZONE AE (FLOODPLAIN) AND ZONE AE (FLOODWAY) PER NCFRIS (PANEL 3989, MAP j 372O39890OK, DATE 0210412009). PROP. GORE AREA (APPROX. 45 SF) EX. PAVED MANEUVER AREA PROP. CLASS B RIP RAP 18" MIN DEPTH (200 SF) DO 1 O ��C IPO13 @@ �4G3MC�40OM z O 0 U N W U tY N �W U w W N w�Q 0 Z Z J aU ZU wLO04 zc�v= oo m R,wo oo QO0z oioi o U z— i rn rn 20<() 65 0 0 _j O X z0�� dii 4a w2 4o �4 Z Q y U W�, 06111120 File Name: RFTHSIR££T.dwg 0 1 0 20 Surveyed: DC Designed: MM Drawn: MM Approved: Sheet No. Scale 1 " = 10' CD-2. o 8" TIP TIMBER PILE, TYP. TIE PROP. SEAWALL TO EX. BULKHEAD CONTRACTOR RESPONSIBLE FOR (SEE INSERT A) CONSTRUCTION OF VINYL SHEETPILE GROIN AND PILE INSTALLATION - EX. T&G BULKHEAD (TO REMAIN 26" F�----------------- --------------------------- ------------ --------------------------------------------------------- -4 — — — — — — — — — — — — — — — I — -- — -- — -- — -- — -- L — -- — -- — -- — -- 1 CONTRACTOR RESPONSIBLE FOR CONSTRUCTION OF VINYL E GROIN AND PILE INSTALLATION EX. T&G BULKHEAD WRAP CORNER WITH 3'X3' (TO REMAIN) COMPACTABRIC. BACK FILL AND SECURE VINYL TO EX. WALL WITH LAG SCREWS SPACED VERTICALLY EVERY 6" 8" TIP TIMBER PILE, TYP. INSERT A SITE NOTES: 1. OWNER TO PROVIDE SHEETPILE FOR GROIN. 2. CONTRACTOR TO PROVIDE TIMBER PILES AND ALL NECESSARY EQUIPMENT AND HARDWARE FOR VINYL GROIN CONSTRUCTION. J TIMBER PILES TO BE MINIMUM 8" TIP DIAMETER AND DRIVE TIP DOWN. 4. SEE SHEET CD-6.1 AND CD-8.0 FOR PROFILE AND ADDITIONAL DETAILS IPMUNHI°- Qf DO a04 U31E p@n @@H3U12U@4001N1 z 0 cC C 0 U w �w OU rn W W X W N W Q 0 Z Z J U <KwU zC9U2 0o rn pWW0 oo QO0z rnrn o Uz= 2 rnrn 20<() 65 0 _j O X 0 z0�� dii a wm .o ;4 Z Q y U W, 06111120 File Name: RFTHSIR££T.dwg 0 1 0 20 Surveyed: DC Designed: MM Drawn: MM Approved: Sheet No. Scale 1 " = 10' CD-2. l I ' �1 PROP. VINYL GROIN - TOP EL. 132.00' (RE- 1/CD-6.1 & CD-8.0) PROP. GROIN IN FOOTPRINT OF EX. GROIN LOD D — LOD 1 0 PRO CONC. A P \ 122 (RE- CD- .O & CD o 1) \ o o / 6' do CID O 0 p0 I I 122I L LOD i �ROP. GROIN IN OF EW. �pOT INTN \ GROI \ \ PRO . VINYL p - I TOP $L. 13 .00' (E' 1 CDr6.1 CD 8.0) GRADING / E&SC NOTES: p I U ti . BULKHEAD � L — — — — — — ---------------------� I o� (TO REMAIN) I I I I � PROP. ADA SIDEWALK REPLACEMENT I I I I I (RE. CD-82- I I I BULKHEAD STABILI E DISTURBED AREA ITCPROP. SEAWALL (RE. 1/CD-4.3) — LOD OD — LOD T LOD — L TD T D 3 .60 3 $� I 00 (14 � I7, Li I +1 2 I / I I I I I I I I I I I 1 I I OD LOD LOD —� LOD — � — LOD T LOD — Lb7 LOD �W- LOD / I \ / FLOODWAY BOUNDARY (PER N&I?/S) / I cV I r --/ -_-�_-7�Jr / / / 1. TOTAL DISTURBED AREA: 5,821 SF (0.13 ACRES) 2. TOPOGRAPHIC INFORMATION BASED ON SURVEY PERFORMED BY NCWRC STAFF. NO GEOTECHNICAL EVALUATION, UTILITIES LOCATION, OR BOUNDARY SURVEY HAS BEEN PERFORMED ONSITE. J. NO UTILITIES HAVE BEEN LOCATED. CONTACT 811 PRIOR TO COMMENCEMENT OF WORK. 4. ALL WORK TO TAKE PLACE WITHIN EXISTING RAMP FOOTPRINT 5. SPOT ELEVATIONS REFER TO TOP OF FINISHED CONCRETE. 6. MAX. 3:1 SIDE SLOPE FROM EDGE OF PARKING/AREA TO EXISTING GRADE UNLESS OTHERWISE NOTED. 7. MAX. 3:1 SIDE SLOPE ALONG EDGE OF RAMP. ARMOUR WITH CLASS B RIP RAP (18" DEEP) WITH GEOTEXTILE UNDERLAY. 8. PROJECT SITE LOCATED IN ZONE AE (FLOODPLAIN) AND ZONE AE (FLOODWAY) PER NCFRIS (PANEL 3989, MAP # 3720398900K, DATE 0210412009). I I I�OG3 C�OMn �4G3MC�400Mn I / z � O I U to 30 I I W=U W> EX. PAVED I W w N MANEUVER AREA U- w z 0 Z Z J Ww w I I aZW� � zz 0o� rn / I I oLLWo -00-.2- I QO�z rnrn-o �z-= Y,Y,-� I �U)26 I W >_� I 0 0 � z o a I 331 (PROP. SMOOTH (TRANSITION TO I EX. PAVEMENT I N.t N O p I W I I � I 33 00 / V — — - STABILIZE DISTURBED AREA WITH CLASS B RIP RA P - _ z FLVOf1PLAfN B9l AVOY (PER NCFRIS) 10 0 10 20 Scale 1" = 10' 06111120 File Name: RFTHSIR££T.dwg Surveyed: DC Designed: MM Drawn: MM CD-3.0 SEEDING MIXTURE SPECIES RATE (LB/ACRE) RYE (GRAIN) 120 ANNUAL LESPEDEZA (KOBE IN PIEDMONT/COASTAL PLAIN, 50 KOREW IN MOUNTAINS) OMIT ANNUAL LESPEDEZA WHEN DURATION OF TEMPORARY COVER IS NOT TO EXTEND BEYOND JUNE SEEDING DATES MOUNTAINS: ABOVE 2500 FEET: FEB. 15 — MAY 15 BELOW 2400 FEET: FEB. 1 — MAY 1 PIEDMONT- JAN. 1 — MAY 1 COASTAL PLAIN: DEC. 1— APR. 15 SOIL AMENDMENTS FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY ZOOO LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 750 LB/ACRE 10-10-10 FERTILIZER. MULCH APPLY 4,000 LB/ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, REFERTILIZE AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. 1 /CD-4.3 TEMPORARY SEEDING FOR LATE WINTER & EARLY SPRING SEEDING MIXTURE SPECIES TALL FESCUE RYE (GRAIN) KOBE LESPEDEZA RATE (LB/ACRE) 80 20 10 SEEDING NOTES AFTER AUG. 15, USE UNSCARIFIED SERICEA SEED. WHERE PERIODIC MOWING IS PLANNED OR A NEAT APPEARANCE IS DESIRED, OMIT SERICEA AND INCREASE KOBE LESPEDEZA TO 40 LB/ACRE. TO EXTEND SPRING SEEDING DATES INTO JUNE, ADD 15 LB/ACRE HULLED BERMUDA GRASS, HOWEVER, AFTER MID—APRIL IT IS PREFERABLE TO SEED TEMPORARY COVER. NURSE PLANTS BETWEEN MAY 1 AND AUG. 15, ADD 10 LB/ACRE GERMAN MILLET OR 15 LB.ACRE SUDANGRASS. PRIOR TO MAY 1 OR AFTER AUG. 15, ADD 40 LB/ACRE RYE (GRAIN). SEEDING DATES BEST POSSIBLE FALL: AUG. 25—SEPT. 15 AUG. 20 — OCT. 25 LATE WINTER: FEB. 15—MAR. 21 FEB 1. — APR. 15 FALL IS BEST FOR TALL FESCUE, AND LATE WINTER FOR LESPEDEZAS. OVERSEEDING OF KOBE LESPEDEZA OVER FALL —SEEDED TALL FESCUE IS VERY EFFECTIVE. SOIL AMENDMENTS APPLY LIME AND FERTILIZER ACCORDING TO SOIL TESTS, OR APPLY 4,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 1,000 LB/ACRE 10-10-10 FERTILIZER. MULCH APPLY 4,000 LB/ACRE GRAIN STRAW OR EQUIVALENT COVER OF ANOTHER SUITABLE MULCH. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE REFERTILIZE IN THE SECOND YEAR UNLESS GROWTH IS FULLY ADEQUATE. MAY BE MOWED ONCE OR TWICE A YEAR, BUT MOWING IS NOT NECESSARY. RESEED, FERTILIZE, AND MULCH DAMAGED AREAS IMMEDIATELY. 4/C D-4.3 PERMANENT SEEDING SEEDING MIXTURE SPECIES GERMAN MILLET RATE (LB/ACRE) 40 IN THE PIEDMONT AND MOUNTAINS, A SMALL —STEMMED SUDANGRASS MAY BE SUBSTITUTED AT A RATE OF 50 LB/ACRE. SEEDING DATES MOUNTAINS MAY 15 — AUG. 15 PIEDMONT- MAY 1 — AUG. 15 COASTAL PLAIN: APR. 15 — AUG. 15 SOIL AMENDMENTS FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY ZOOO LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 750 LB/ACRE 10-10-10 FERTILIZER. MULCH APPLY 4,000 LB/ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, REFERTILIZE AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. 2/CD-4.3 TEMPORARY SEEDING FOR SUMMER SEEDING MIXTURE SPECIES RYE (GRAIN) SEEDING DATES MOUNTAINS COASTAL PLAN AND PIEDMONT.• RATE (LB/ACRE) 120 AUG. 15 — DEC. 15 AUG. 15 — DEC. JO SOIL AMENDMENTS FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 750 LB/ACRE 10-10-10 FERTILIZER. MULCH APPLY 4,000 LB/ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE REPAIR AND REFERTILIZE DAMAGED AREAS IMMEDIATLEY. TOPORESS WITH 50 LB/ACRE OF NITROGEN IN MARCH. IF IT IS NECESSARY TO EXTEND TEMPORARY COVER BEYOND JUNE 15, OVERSEED WITH 50 LB/ACRE KOBE (PIEDMONT AND COASTAL PLAIN) OR KOREAN (MOUTNAINS) LESPEDEZA IN LATE FEBRUARY OR EARLY MARCH. 3/C D-4.3 TEMPORARY SEEDING FOR FALL SITE AREA DESCRIPTION STABILIZAmON TIMEFRAME EXCEPTIONS Perimeter dikes, swales, ditches, slopes 7 days Nona High Quality Water (HQW) Zones 7 days None Slopes steeper than 3:1 u 7 days If slopes are 10' or less in length and are not steeper than 2:1, 14 days are allowed. Slopes 3:1 or flatter 14 days 7 days for slopes greater than 50' in length. --- "_ All other areas with slopes flatter than 4.1 14 dap None.. except for perimeters and HQW Zones. S/C D-4.3 STABILIZATION TIMEFRAMES PMUNHI°- Qf DO H@U U31E z 0 0 U w �W �w U_ w> aw N LLC9wz 0 Z Z J U <Zw0 J z > H 0wwO aaf p(oz U z J 2 x0<c� a fnow oSNJ z 0 06111120 FIFTHSIREET.dwg eyed: DC gned: MM vn: MM CD-4.3 20' APRON PROVIDE SMOOTH TRANSITION TO EX. PAVEMENT 1 /CD-8.0 RAMP VERTICAL CURVE (ENTIRE RAMP AREA) NTS J/8"x5" HOT DIPPED GALV. CARRIAGE HEAD BOLT, WITH J/8" HOT DIPPED GALV. STEEL HEX HEAD NUT AND J/8" HOT DIPPED GALV. STEEL FLAT WASHER SLAP JOINT IN 4x6 WALER LAP JOINT IN 4X6 WALER 8" TIP TIMBER PILE ­'p Q J/4" x 18" GALV. TIMBER BOLTC d WITH OG WASHER AND NUT u v v v 4 a av � C Q 2/C D-8.0 VINYL SHEETPILE GROIN - PLAN DETAIL NTS 3.0' EL. 1 J2.60' CONCRETE APRON CAST -IN -PLACE REINFORCED CONCRETE INSTALLED BY NCWRC TIMBER WALER J/4" x J,." GALV. TIMBER BOLT-1 WITH OG WASHER AIq NUT (END OF BREAKWAT&R ONLY) J/8"x3-1/2" HOT DIPPED GALV. S�EL LAGXCREW WITH JIB" HOT DIPPED GALV. STEEL FLAT WASHER a v 4 7NCRETE RAMP 4 o -J. 0' EL. 1 J2.40' 4X6 TIMBER WALER J/4" x JO" GALV. TIMBER BOLT WITH OG WASHER AND NUT 8" TIP TIMBER PILE VINYL SHEETPILE CL9900 OR EQUIVALENT --3.0' EL. 1 J2.10' CAP BOARD 3/C D-8.0 VINYL SHEETPILE GROIN - PROFILE DETAIL NTS EL. 1 J 1.70' �p 14.07. SLOPE FLOATING DOCK CONCRETE RAMP p d. DO a04 U31E p@n @@ 3u[2u@400M f) u 2 rn uN 9 W z E H J z W U u W U u ° 00 LWo �1w Jz 0)0)0 0w d 5 t a� a wm 0 0 o Z U W (O 0 a r s YT Z O � ~ J � O W Q L,_JO � 06111120 Vame: FIFIHSTR££T dwg eyed: DC aned: mm in: mm oved: A No. CD-8.0 4" HT. REBAR CHAIR WITH BASE (TYP.) 2.0' USE SIMPLE TI AT EACH CROSSIN #4 BA UNDER # 7 BA.. 14 BAR (TYP.) x8 FORM BOARDS `n' U "J I V I "U ' U V1 "V�'%U BENEATH # 7 BARS (TYP.) BASES TO SUPPORT # 4 BARS (3' MAX. SPACING) (TYP.) NOTES.- 1. ALL REINFORCEMENT, FORM WORK, CONCRETE PLACEMENT, AND CURING PRACTICES SHALL CONFORM TO ACI-316-11 BUILDING CODES FOR STRUCTURAL CONCRETE. READY MIX CONCRETE SHALL MEET ASTM-C94 SPECIFICATION. REINFORCING STEEL SHALL BE GRADE-60 MEETING ASTM-A615 SPECIFICATIONS. 2. BASE FOR RAMP SHALL BE GRADED AS SHOWN IN THE PROFILE ON SHEET CD-6.0 & CD-6.1. J. PROPER BASE FOR SLAB IS 1 FOOT OF SMALL CLASS 8 OR CLASS A RIP RAP COVERED WITH 6" OF WASHED 15, 157, OR 14 STONE. 4. PLACE MIN. 5 MIL POLYETHYLENE BARRIER BENEATH FORM WORK AND REINFORCING STEEL OF PUSH SLABS. 5. FORMS SHALL BE 2x8 LUMBER OR 8" METAL, EXCEPT FOR SLANTED 2x10 USED FOR LEADING EDGE. 6. NOTE 17 BARS ARE PLACED ABOVE 14 BARS 4" HT REBAR CHAIRS ARE PLACED UNDER AND ATTACHED TO 14 BARS IN PATTERN SHOWN IN PLAN VIEW. 7. RE84R CONTACT LAPS SHALL BE MIN. OF 30 TIMES BAR DIAMETER AND JOINED BY SIMPLE TIES. & MAINTAIN MIN. 3" CLEARANCE BETWEEN REBAR AND INSIDE OF FORMS. 9. RUN 17 LONGITUDINAL BARS 24" BEYOND FORM ON UPHILL END OF SLAB THROUGH PREDRILLED HOLES TO FORM POSITIVE BOND WITH SUBSEQUENT SLAB SECTION. REMOVE DRILLED FORM BEFORE POURING NEXT SECTION OF SLAB. 10. WHERE POSSIBLE (NON -TIDAL WATERS), FORM AND POUR PUSH SLAB ON SLOPED SUBGRADE OF RAMPS SO THAT FRONT EDGE OF SLAB IS AT LEAST 3' ABOVE WATER LEVEL. WHERE THERE IS LIKELIHOOD OF TIDAL INUNDATION, POUR SLAB ON FLAT LAND PARALLEL AND IN LINE WITH THE PROPOSED LOCATION IF POSSIBLE. 11. FRONT PLANE OF SLAB SHALL BE ANGLED FORWARD AS SHOWN TO HELP PREVENT SLAB FROM DIGGING IN DURING PUSH. 12. WET FORMS AND BASE PRIOR TO POURING CONCRETE. 13. READY MIX CONCRETE SHALL BE 4500 PSI NCOOT CLASS AA WITH FIBER WITH 4 INCH SLUMP. 14. USE VIBRATORY SCREED TO PREVENT HONEY COMBING. 15. FINISH SURFACE USING A V-GROOVING TOOL FABRICATED OUT OF PARALLEL 1 "xf iri" ALUMINUM ANGLES (AS PER SOBA) TO PLACE 2" O.C. GROOVES AT A 60' ANGLE FROM THE SIDES DOWN THE ENTIRE LENGTH OF THE SLAB. GROOVES SHOULD DIRECT RUNOFF DOWNSTREAM WHEN POSSIBLE. 16. USE AN EDGING TOOL TO CREATE A 4" WIDE SMOOTH FINISH ALONG EACH EDGE TO MINIMIZE SPALLING. 17. ALLOW SLAB TO CURE IN PLACE 21 DAYS BEFORE PUSHING INTO PLACE WITH A DOZER. 18. IN PLACE LOCATION SHOULD LEAVE ENOUGH OF THE PUSH SLAB ABOVE THE WATER LEVEL TO POUR THE NEXT SECTION WITH THE NEW CONCRETE TOUCHING THE WATER. 19. AFTER SLAB IS IN PLACE, ALL ROCK AND DEBRIS SHALL BE REMOVED OFF THE RAMP. 1/CD-8.1 PUSH SLAB SECTION VIEWS NTS DETAIL A 1 j " COVER #7 BOARDS (TYP) BAR '0 HOLES 9. C. IN FORM BOARD IPMUNHI°- Qf DO H@U U31E 7 PUSH SLAB 4" HT. REBAR CHAIR (TYP.) " 2X 10 FORM ARD SLANTED FORWARD LEADING EDGE OF PUSH SLAB DETAIL B z 0 cn 0 U N w U W N =)w OU rn w> W w N LL 0 W z 0 z z J U <Zw0 J z > �- 0ww0 af QOwz U z � _ 20<(7 a fnow OSN� z 0 a E�o 0, �Q U J Q O J 0 Date: 06111120 File Name: FIFTHSTR£ET dwg Surveyed: DC Designed: MM Drawn: MM Approved: Sheet No. CD-8.1 # 7 DOWELS EXTEND 24" BEYOND FORM TO REFER TO 2 C08.2 FOR CONNECT TO NEXT SECTION OF RAMP SLAB REMOVE FORM BEFORE NEXT POUR SURFACE FINISHING DETAIL 8" MIN. 4500 PSI CONCRETE PMUNHIff DO H@U MACE 7 LONGITUDINAL BARS 0 12" O.C. (RE: 1/CD-6.4) =1 Oil 0 14 TRANSVERSE BARS 0 18"" O.C, 2" O.C. GROOVE FINISH cn AT 60' ANGLE FROM SIDES 2x8 FORM BOARDS 4" HT REBAR CHAIR WITH BASE o cn w U � w 6" WASHED # 57 STONE U_ w > tY w W (n z 12" CLASS A RIP RAP o z z U 4" SMOOTH FINISH ALONG BO EDGES QZwUU z z > E owp o rn J � � o COMPACTED SUBGRADE oa LL W p 0 0 g QOrnrn-a U Z—Q i rn rn NOTES oS0J o u 1. REFER TO 1/CD-8.1 FOR CONCRETE AND REBAR DETAILS z c �: � a u NOTES 1. REFER TO 1/CD-8.1 FOR CONCRETE AND REBAR DETAILS. y a wm 2. GROOVE FINISH SHALL BE INSTALLED ON RAMPS UNLESS 1/CD-8.2 2/CD-8.2 OTHERWISE INDICATED Z < ° o RAMP DETAIL RAMP FINISH DETAIL NTS NTS Y O 5.5" MIN. 4000 PSI CONCRETE x v ° 4 4QD m d v 4 v d 4" COMPACTED ABC O Z O � J 8" (MIN.) COMPACTED Q C COMPACTED SUBGRADE AGGREGATE BASE W W COURSE STONE O 1110v C/) COMPACTED SUBGRADE CONCRETE NOTES 1. CONSTRUCT CONCRETE SIDEWALK 5' WIDE UNLESS OTHERWISE DENOTED ON THE PLANS. IIIIIIIIIIIIIIII 2. PLACE A GROOVE JOINT 1" DEEP WITH %8" RADII AT 5' INTERVALS. ONE!12" EXPANSION JOINT REQUIRED AT 50' INTERVALS AND WHERE SIDEWALK JOINS ANY RIGID STRUCTURE OR DIFFERENT MATERIAL. J. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 4500 PSI WITH FIBER AN AIR ENTRAINED CONTENT OF 69 4. BROOM FINISH SIDEWALKS 5. ALL SIDEWALKS SHALL HAVE A MAXIMUM RUNNING SLOPE OF 5.0% AND MAXIMUM CROSS SLOPE OF 2.0% `= Date: 06111120 File Name: FIFTHSTR£ET dwg 3/CD-$.2 4/CD-$.2 Surveyed: DCDesigned: CONCRETE PAVEMENT GRAVEL PARKING MM Drawn: MM NTS NTS Approved: Sheet No. CD-8.2 6 91" 14 BARS @ 12" O.C. B C) 0 N A WOODEN FORM WORK (TYP) WOODEN FORM WORK (TYP)-\ 4" 11" 14 BAR SUPPORT FOR ANCHOR BOLTS 1 /CD-8.3 FLOATING DOCK ABUTMENT NTS PLAN VIEW B B 14 BARS ® 12" O.C. 11 " A 11 " 6 11 " 6 11 " 14 BARS ® 12" O.C. SAFETY CHAIN) h ANCHOR BOLT SECTION A -A Mmmm8'� 4" HT. REBAR CHAIR WITH BASE (TYP) (2' MAX. SPACING) pnHUNHI°- Qf DO H@U U31E --4" HT. REBAR CHAIR NOTES: WITH BASE (TYP) (2' 1. ALL REINFORCEMENT, FORM WORK, CONCRETE PLACEMENT, AND CURING PRACTICES SHALL MAX. SPACING) CONFORM TO ACI-J18-11 BUILDING CODES FOR STRUCTURAL CONCRETE. READY MIX CONCRETE SHALL MEET ASTM-C94 SPECIFICATION. REINFORCING STEEL SHALL BE GRADE-60 MEETING ASTM-A615 SPECIFICATIONS. 2. ABUTMENT BASE MUST BE LEVEL BEFORE PLACING FORMS AND REINFORCING STEEL. J. MAINTAIN MIN. J" CLEARANCE BETWEEN REINFORCING STEEL AND INSIDE OF FORMS AND 2" CLEARANCE BETWEEN TOP OF STEEL AND TOP SURFACE OF CONCRETE. 4. TIE STEEL USING SIMPLE WIRE TIE CONNECTIONS AT EACH INTERSECTION. 5. SUPPORT REBAR CAGE USING 4" HT. REBAR CHAIRS ATTACHED TO STIRRUPS AT 2MAX. SPACING. 6. INSTALL ALL ANCHOR BOLTS FOR PIANO HINGE AND SAFETY CHAIN THROUGH PREDRILLED HOLES IN FORM WORK. SECURE WITH WASHERS AND NUTS TO OUTER FACE OF FORM. TIE BOLTS TO REBAR CAGE. A 7. BLOCK OUT AS NECESSARY FOR PIANO HINGE. 8. USE VIBRATOR TO CONSOLIDATE CONCRETE AND ELIMINATE VOIDS IN CORNERS AND AROUND EMBEDDED OBJECTS. 9. READY MIX CONCRETE SHALL BE 4500 PSI NCDOT CLASS AA WITH FIBER WITH 4" SLUMP. 16" LAP JOIN WITH SIM J'1018"Lx4'J HDG ANCHOR BOLTS (TYP). SET IN PREDRILLED FORM HOLES WITH 14" OF THREAD EXPOSED PAST OUTSIDE OF FORM AND TIED TO REBAR CAGE. FOR ANCHOR BOLTS 2" MIN. CLEARANCE BETWEEN TOP OF z O O U N W U N � W OU rn U) CF) W W N LLoLuZ LL 0 Z z J U aZWU J Z > 1 OWw0 ¢LL 0 z U Z _ 20<(7 �U)0 W 05_Ngj ZO�LC a E�o 0, ZQ U S, O Lo(o 0o rn 002 a; a; rn rn � U N � C aLL FORM FIFTHSTREET.dwg lyp) Surveyed: DC Designed: MWL Drawn: MWL CD-8. J