HomeMy WebLinkAboutNCS000589_MONITORING INFO_20200129R 0
STORMWATER DIVISION CODING SHEET
NCS PERMITS
PERMIT N0.
n' r 0
DOC TYPE
❑ FINAL PERMIT
4 MONITORING REPORTS
❑ APPLICATION
❑ COMPLIANCE
❑ OTHER
DOC DATE
❑"J 1 ��
YYYYMMDD
DUKE
ENERGY®
PROGRESS
January 22, 2019
Certified Mail rk 7016 i i30 0001 4419 M3 (2 copies)
NC DEQ—DWR, Central Files
1617 Mail Service Center
Raleigh, North Carolina 27699-1617
Subject: Weatherspoon's 4th Quarter 2019
Stormwater Discharge Monitoring Report (DMR) Submittal
Dear Sir or Madam:
W. H. Wealherspoon Plant
491 Power Plant Rd
Lumberton, NG 28358
Mailing A ddress:
Kent Tyndall
L. V. Sutton Energy Complex
EC EIVuon Steam
' itt, ngton, NC'Iant 2&401d
JAN 2 9 2020 1: 910.341-4790
-�ENTRAL FILES
0m, SECTION
Duke Energy Progress, LLC submits in duplicate the fourth quarter 2019 Stormwater Discharge
Monitoring Report for W. H. Weatherspoon. This submission is for the sample collected 12/13/2019, and
is made in accordance with Part III, Section E of our NPDES Stormwater Permit No. NCS000589.
SW-2 is in Tier I status due to 12/14/201 B TSS sampling result being above the benchmark value.
Therefore, we are required to conduct monthly (analytical and qualitative) monitoring at this outfall until
three consecutive sample results are below the benchmark values or within benchmark range.
• TSS was below benchmark for the 11/15I2019 sample
• TSS was below benchmark for this 12/13/2019 sample
SW-2 is also in Tier I status due to 12/13/2019 Zinc sampling result being above the benchmark value.
Therefore, we are required to conduct monthly (analytical and qualitative) monitoring at this outfall until
three consecutive sample results are below the benchmark values or within benchmark range.
If there are any questions, please contact either.
• Mr. Kent Tyndall, EHS Professional for the W. H. Weatherspoon Plant; phone (910) 341-4775 or
e-mail Kent.Tyndall0duke-energy.com; or
• Ms. Joyce Dishmon, Environmental Specialist with our Environmental Permitting and Compliance
Group, phone (336) 623-0238 or email Joyce. Dishmon®duke-energy.com.
Please direct all correspondence to Kent Tyndall via the mailing address shown above.
I certify, under penalty of law, that this document and all attachments were prepared under my direction or
supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the
information submitted, Based on my inquiry of the person or persons who manage the system, or those persons
directly responsible for gathering the information, the information submitted is, to the best of my knowledge and
belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information,
including the possibility of fines and imprisonment for knowing violations.
Sincere]
Jeffrey r-um icLyar i
Station Manager
STORNIWATER DISCHARGE OUTFALL (SDO)
MONITORING REPORT
Permit Number NCS000589
FACILITY NAME W. H. Weatherspoon Planl JAN 2 9 Z020
PERSON COLLECTING SAMPLE(S) Ricky Stroupe b ,
CERTIFIED LABORATORY(S)Shealy Environmental Services. Inc'.1Y.,ab=%
Duke Power Company LLC d/b/a Duke Energy Carolinas. LLC Lah 48
Duke Energv Progress -Sutton Stearn Electric Plant Lab # 5056
Part A: Specific Monitoring Requirements
SAMPLES COLLECTED DURING CALENDAR YEAR: 2019
(This monitoring report shall be received by the Division no later than 30 days from
the date the facility receives the sampling results frum the labotutory.)
COUNTY Robeson
PHONE NO. Kent Tyndall, o: 910-341-4775
SIGNATURE OF PERIUI'I'rEE OR DESIGNEE
RFQUIRED ON PAGF 2.
Outfall
No.
Date
Sample
Collected
50050
00400
00530
01097
Total
Flow (if app.)
Total
Rainfall
pH
Precip pH
(if taken)
TSS
Non -Polar
Oil & Grease
Antimony
(Sb)
mo/dd/yr
MG
inches
Units .
Units
mg/L
mg/L
mg/L
SW-1
No Discharge
SW-2
12/13/2019
N/A
0.87
7.9
14
<5.0
<0.001
SW-3
No Discharge
Benchmark
Value
I
I
6-9; (IF precip pH is lower,
ITHEN lower threshold is precip pH.)
100
15
0.09
Outfall
No.
01002
01012
01027
01034
01042
01051
71900
01067
01147
Arsenic
(As)
Beryllium
(Be)
Cadmium
(Cd)
Chromium
(Cr)
Copper
(Cu)
Lead
(Ph)
Mercury
(Hg)
Nickel
(Ni)
Selenium
(Se)
mg/L
mg/L
mg/L
mg/L
mg/L
mg/L
ng/L
mg/L
mg/L
SWA
SW-2
0.0028
<0.001
<0.001
0.001
0.00804
0.00606
9.93
0.00583
<0.00161
SW-3
Benchmark
Value
0.34
0.065
0.003
0.9
0.01
0.075
12
0.335
0.056
Outfall
No.
01077
01092
01022
01059
Silver
(Ag)
Zinc
(Zn)
Boron
(B)
Thalhium
(TI)
mg/L
mg/L
mg/L
mg/L
SW-1
SW-2
<0.000287
0.212
<0.05
<0.000224
SW_3
Benchmark
Value .11
0.0003
0.126
Form SWU-247, last nwised 212/2012
Facility Name W. H. Weatherspoon Plant
Permit Number NCS000589
Does this facility perform Vehicle Maintenance Activities using more than 55 gallons of new motor oil per month?
(if yeti, complete Part 13)
Part B: Vehicle Maintenance Activity Monitoring Requirements
No
Outfall
No..
Date
Sample
Collected
50050
00556
00530
00400
Total Flow
(if applicable)
Total Rainfall
Oil & Grease
(if appl.)
Non -polar
O&GCTPH
(Method 1664
SCT-HEM), if
appl.
Total
Suspended
Solids
pH
New Motor
Oil Usage
mo/ddlyr
MG
inches
mg/L
mg/L
unit
gal/mo
STORM EVENT CHARACTERISTICS: Mail Original and one copy to:
Division of Water Quality
Date 12/13-14/2019 Attn: Central Files
Total Event Precipitation 1.04 (inches) 1617 Mail Service Center
Event Duration (hours) (only if applicatle - sec permit.) Ralei!_,h. North Carolina 27699-1617
(il' more than one storm event was sampled)
Date
Total Event Precipitation (inches)
Event Duration (hours) (only if applicatle - see permit.)
"I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a
system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person
or persons who manage the system, or those persons directly responsible for gathereing the information, the information submitted is, to the
best of my knowledge and belief , true, accurate, and complete. I am aware that there are significant penalties for submitting false information,
including the possibility of fines and impriWnment for knowing violations."
Jeffrey Flan
(Signature of
1 /22/2020
(Date.)
Pa,e I of 2
Form SWU-247. last revised 2/2/2012
Pa,,e 2 of 2