Loading...
HomeMy WebLinkAboutNCS000088_COMPLETE FILE - HISTORICAL_20191113STORMWATER DIVISION CODING SHEET .,--........:; RESCISSIONS . PERMIT NO. �f �S DOC TYPE COMPLETE FILE'- HISTORICAL DATE OF RESCISSION I. YYYYMMDD X HEXION" November 7, 2019 Hexion Inc. 1411 Industrial Drive Fayetteville, NC 28301 hexion-com Department of I -Energy, Mineral, and band Resources Attn: Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Nov 131019 OW} AL FILES RSECTION RIB: 2019 — 2"' ]-fall Semi -Annual Stormwatcr Discharge Outfall Monitoring Report In accordance with our permit, NCS000088, enclosed are two copies of' the semi-annual Stormwatcr Discharge Outfal I Monitoring Report for the second half of 2019. Should you have any additional questions, please do not hesitate to contact me at (910) 485-9249, or Caleb Stoker at (910) 364-5064. Sincerely, 1-I1X10N INC. Cc: Caleb Stokcr, I-Icxion Jeff Ham i]ton, I-Iexion STORM WATER DISCHARGE OUTFALL (SDO) MONITORING REPORT Permit Number NCS000088 FACILITY NAME Hexion. INC - Favetteville PERSON COLLECTING SAMPLE(S) Sonva Myers CERTIFIED LABORATORY(S) Envirochem Lab #1 94 Part A: Specific Monitoring Requirements SAMPLES COLLECTED DURING CALENDAR YEAR: 2019 (This monitoring report shall be received by the Division no later than 30 days from the date the facility receives the sampling results from the laboratory.) COUNTY Cumberland PHONE NO. (910) 483-1311 SIGNATURE OF PERMITTEE OR DESIGNEE REQUIRED ON PAGE 2. Outfall Date No. Sample Collected Total Flow (if app.) Total Rainfall Biochemical Oxygen Demand Chemical Oxygen Demand Methanol Total Kjeldahl Nitrogen TKN Total Nitrogen (TN) Ammonia, Total (as Nitrogen) pH mo/dd/vr MG inches m /L m /L m /L m /L m IL m IL standard 001 10/14/2019 N/a 0.92 6 35 <5 4.4 5.0 0.8 6.57 002 10/14/2019 N/a 0.92 6 27 <5 18.5 25.4 42 6.67 003 10/14/2019 N/a 0.92 6 41 <5 3.2 3.6 0.4 6.22 Does this facility perform Vehicle Maintenance Activities using more than 55 gallons of new motor oil per month? 0 yes CF- no (if yes, complete Part B) Part B: Vehicle Maintenance Activitv MonitoringRe uirements Outfall No. Date Sample Collected 50050 00556 00530 _ 00400 Total Flow (if applicable) Total Rainfall Oil & Grease (if appl.) Non -polar O&G/TPH (Method 1664 SGT-HEM), if appl. Total Suspended Solids pH New Motor Oil Usage mo/dd/yr MG inches mg/1 m /l unit al/mo Form SWU-247. last revised 611212015 Pagel of 2 STORM EVENT CHARACTERISTICS: Date 10/14/2019 Total Event Precipitation (inches): 0.92 Event Duration (hours): (only if applicable - -see permit.) (if more than one storm event was sampled) Date Total Event Precipitation (inches): Event Duration (hours): (only if applicable — see permit.) ;Mail Original and one copy to: Division of Enerpav and Land Resources Attn: Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 "1 certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge a e, accurate, and complete. i am aware that there are significant penalties for submitting false information, including the possib' ty of fines a�mprisonment for knowing violations." ittee) 1( - 7 I' (Date) Form SWU-247, last revised 611212015 Page 2 of 2 l�Nl e, ANALYTICAL & CONSULTING CHEMISTS Hexion-Fayetteville, NC 1411 Industrial (Drive Fayetteville NC Attention: Lab ID Sample ID: 19-44398 Site: Outfall 001 Test Ammonia Nitrogen BOO COD Methanol Total Nitrogen (Cale) Total Kjeldahl Nitrogen (TKN) Nitrate+Nitrite-Nitrogen Total Nitrogen Lab ID Sample ID: 19-44403 Site: Outfall002 Test Ammonia Nitrogen BOD COD Methanol T601 Nitrogen (Cale) Total Kjeldahl Nitrogen (TKN) Nitrate+Nitrite-N itroge n Total Nitrogen Environmental Chemists, Inc. 6602 Windmill Wav, Wiimington, NC 29405 . 910,392.0223 Lab . 910.392.4424 Fax 710 Bowwrtown Road, Manteo,,NC 27954 . 252.473.5702 Lab!F,Fs 255-A Willnington Highway, Jacksonville, 1\C 28540 . 910.3,17.5843 l.ob/Fax infb ,'environmenIalchemists.com Date of Report: Oct 23, 2019 Customer PO #: 28301 Customer ID: 18080043 Report #-. 2019-17363 Project ID: Collect DatelTime Matrix 10/14/2019 5-15 AM Water Method EPA 350.1 SM 5210 B SM 52200 SW 846 method 8015 EPA 351.2 EPA 353,2 Total Nitrogen Collect DatelTime 10/14/2019 5:09 AM Method EPA 350.1 SM 5210 B SM 5220D SW 845 method 8015 EPA 351.2 EPA 353.2 Total Nitrogen Results Sampled by Date Analyzed 0.8 mg1L 10/16/2019 6 mg/L 10/15/2019 35 mg/L 10/15/2019 <5 mg/L 10/15/2019 4.4 mg/L 10/1912019 0, 56 mg/L 10/16/2019 5.0 mg/L 10/21/2019 Matrix Sampled by Water Sonya Myers Results Date Analyzed 4.2 mg/L 10/16/2019 6 mg1L 10/1512019 27 mg/L 10/15/2019 <5 mg/L 10/15/2019 18.5 mg/L 10/19/2019 6.89 mg/L 1011612019 25.4 mg/L 10/21/2019 Report #,: 2019-17363 Page 1 of 2 Environmental Chemists, Inc. 6602 Windmill 4Vay, Wilminglon, NC 28,105 • 920,392,0223 Lab • Q10.392.4424 Fax 710 Bowsertown Tlnarl, 114antoo, NC 27954 • 252.473.5702 Lab/Fax 255-A Wilniiiigton Highway, ]acksonviIle, NC 28540 • 910347.5M3 Lab/Fax• ANALYTICAL & CONSULTING CHEMISTS info( )eirviroilmenlalcliemists.Corn hlexion-Fayetteville, NC Date of Report: Oct 22, 2019 1411 Industrial Drive Customer PO #: Fayetteville NC 28301 Customer ID: 18080043 Attention: Report #: 2019-17363 Project ID: Lab ID Sample ID: Collect DatetTime Matrix Sampled by 19-44404 Site: Outfall 003 10/14/2019 5:00 AM Water Sonya Myers Test Method Results Date Analyzed Ammonia Nitrogen EPA 350.1 0.4 mg/L 10/16/2019 BOD SM 5210 B 6 mg/L 10/1512019 COD SM 5220D 41 mg/L 10/15/2019 Methanol SW 646 method 8015 <5 mg/L 10115/2019 Total Nitrogen (Ca1e) Total Kjeldahl nitrogen (TKN) EPA 351.2 3.2 mg/L 10/19/2019 Nitrate+Nitrite-Nitrogen EPA 353.2 0.42 mg/L 10/16/2019 Total Nitrogen Total Nitrogen 3.6 mg/L 10/21/2019 Comment: Reviewed by; Report #:: 2019-17363 Page 2 of 2 F ENVIRONMENTAL CHEMISTS, INC Analytical & Consulting Chemists NCOENR: DWQ CERTIFICATION # 94 NCDHHS: DLS CERTIFICATION # 37729 COLLECTION AND CHAIN OF CUSTODY 6602 Windmill Way Wilmington, NO 28405 OFFICE: 910-392-0223 FAX 910-392-4424 info@environmentalchemists.com Client: Hexion-Fa etteville, NC PROJECT NAME: Semi -Annual Storm Water Samples REPORT NO: L 5' ` (7 3� ADDRESS: 1411 industrial Drive CONTACT NAME: Sonya Myers POND: Fayetteville, NC 28301 REPORT TO: Sonya Myers PHONE/FAX: COPY TO: Caleb Stoker email: caleb.stoker@hexion.com Sampled By: <-r. )o; Y"( e(� SAMPLE TYPE: I = Influent, E = Effluent, W = Well, ST = Stream, SO = Soil, SL = Sludge, Other: Sample Identification CollectiorT E a tn~ n c U w = o` U `o m U a Mq g J Z PRESERVATION . ANALYSIS REQUESTED Date Timeemp z z U o = O Z o r w O Outfall 001 Io-ICI-!`i 45 kS � nL G G X McOH Outfall 001 " G P X BOD Outfall 001 , < �' C`� G P X COD, Ammonia as N, TKN, Nitrogen Total Outfall 001 G P X �QC Outfali 002 0-{ - S'b� G G X McOH Outfall 002 �" G P X BOD Outfall 002 << + t ` G P X COD, Ammonia as N, TKN, Nitrogen Total Outfall002 { G P X Outfall 003 10 -I9 QS!C.n � cL G G X McOH Outfall 003 7f t " G P X BOD Outfall 003 �' ` G P X COD, Ammonia as N, TKN, Nitrogen Total Outfall 003 ' < < < !s G P X Metals: Transfer elinqui ed By: DatefTime R Date/Time 2 Temperature when Received: Accepted: Rejected: Delivered By: Received By: Comments: Resample Requested: Date TURNAROUND: Time: