Loading...
HomeMy WebLinkAboutNCS000008_COMPLETE FILE - HISTORICAL_20190430---STURMWATER DIVISION CODING SHEET RESCISSIONS0.0 PERMIT N0. R.c DOC TYPE [�J, COMPLETE FILE- HISTORICAL DATE OF RESCISSION I. ❑ J UI I YYYYMMDD 0 STORMWATER DIVISION CODING SHEET .NCG PERMITS PERMIT NO. NCGNE DOC TYPE ❑ HISTORICAL FILE DOC DATE ❑ YYYYM M D D is APR 3 0 Z019 uENTRAL FILES Storm Water Prevention Plan D\NR SECTION Fortress Wood Products, Inc. Elizabeth City, NC STORM WATER DISCHARGE OUTFALL (SDO) SUMMARY DATA MONITORING REPORT (DMR) Calendar Year 2019 Individual NPDES Permit No. NCS000008 or Certificate of Coverage (COG) No. NCG This monitoring report summary of the calendar year is due to the DWQ Regional Office no later than March 15t of the following year. Facility Name: Fortress Wood Products, Inc., 899 Foreman Bundy Road, Elizabeth City, NC 27909 County: Pasquotank Phone Number: (252) 264-2466 Total number of SDOs monitored: 5 Outfall No. 1 Is this outfall currently in Tier II (monitored monthly)? Yes [X] No a Was this outfall ever in Tier li (monitored monthly) in the past year? Yes [X] No a If this outfall was in Tier II for the fast year, why was monthly monitoring discontinued? Enough consecutive samples below benchmarks to decrease frequency [] Received approval from DWQ to reduce monitoring frequency (] Other Was this SDO monitored because of vehicle maintenance activities? Yes a No [X] Parameter„(units): Ammonia 1.Copper, Total Tier LI;Monthly Rainfall, BOD5 COD Total 4 #ftotal R, +TSS" H p" Inches (5.day) Nitrogen r ' - Non-Trout[ecoverable Benchmark NIA 30 120 7.2 0.007 100 6-9 Date Sanipld•„ . Collected,. 03/3112019 Tier II NO FLOW Page 1 of 4 Storm Water Prevention Plan Fortress Wood Products, Inc. Elizabeth City, NC Outfall No. 2 Is this outfall currently in Tier 11 (monitored monthly)? Yes [X] No a Was this outfall ever in Tier II (monitored monthly) in the past year? Yes [X] No a If this outfall was in Tier II for the last year, why was monthly monitoring discontinued? Enough consecutive samples below benchmarks to decrease frequency n Received approval from DWQ to reduce monitoring frequency a Other D Was this SDO monitored because of vehicle maintenance activities? Yes a No [X] Parameter, (u'nits) Total A: onia Tier II Monthly Rainfall, BODS Total COD (5 day) Nitrogen lIIIIjIIIIjIIICopper total a aInches NOn�Tiro.ut recoverable Benchmark NIA 30 120 7.2 0.007 100 6-9 Date Sample Collected, D3131l2019 Tier II NO FLOW Outfall No. 3 Is this outfall currently in Tier II (monitored monthly)? Yes [X] No a Was this outfall ever in Tier 11 (monitored monthly) in the past year? Yes [X] No 0 If this outfall was in Tier II for the last year, why was monthly monitoring discontinued? Enough consecutive samples below benchmarks to decrease frequency n Received approval from DWQ to reduce monitoring frequency [] Other [] Was this SDO monitored because of vehicle maintenance activities? Yes a No [X] Pyarameter, (u_nitsJ Total Copper Tier 11 Monthly IAV Rainfall, BOD5 Total COD total Ein Inches (5 day) Nitrogen recoverable Nonl7rout Benchmark NIA 30 120 7.2 0.007 100 6-9 Date Sample Collected, 0313112D19 Tier 11 NO FLOW Page 2 of 4 Storm Water Prevention Plan Fortress Wood Products, Inc. Elizabeth City, NC Outfall No. 4 Is this outfall currently in Tier II (monitored monthly)? Yes [X] No a Was this outfall ever in Tier II (monitored monthly) in the past year? Yes [X] No [] If this outfall was in Tier II for the last year, why was monthly monitoring discontinued? Enough consecutive samples below benchmarks to decrease frequency j] Received approval from DWO to reduce monitoring frequency p Other Was this SDO monitored because of vehicle maintenance activities? Yes a No [X] Parameter, (units) Total Ammonia Tier II Monthly Rainfall, BODS Totat Copper Inches (5 day) COD Nitrogen total nn Noniirout recoverable Benchmark NIA 30 120 7.2 0.007 100 6-9 Date Sample Collected, 03131/2019 Tier 11 NO FLOW Outfall No. 5 Is this outfall currently in Tier II (monitored monthly)? Yes [XI No Q Was this outfall ever in Tier II (monitored monthly) in the past year? Yes [XI No a If this outfall was in Tier II for the last year, why was monthly monitoring discontinued? Enough consecutive samples below benchmarks to decrease frequency 0 Received approval from DWO to reduce monitoring frequency fl Other a Was this SDO monitored because of vehicle maintenance activities? Yes a No [X] Parameter, {units) Total Tier II Monthly Rainfall, BODS COD "(NontWoutAMEN Inches (5 day.) Benchmark NIA 30 120 7.2 0.007 100 6-9 Date Sample Collected, 0313112019 Tier 11 NO FLOW Page 3 of 4 I certify under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. i am aware there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." Responsible Official Signature: Printed Name: Ken McBride Title: Director of Manufacturing Date: 3/31 /2019 Page 4 of 4 APR 0 8 2019 Storm Water Prevention Plan CLNTRAL FILES Fortress Wood Products, Inc. DVVR -S CTIOi i Elizabeth City, NC STORM WATER DISCHARGE OUTFALL (SDO) SUMMARY DATA MONITORING REPORT (DMR) Calendar Year 2019 Individual NPDES Permit No. NCS000008 or Certificate of Coverage (COC) No. NCG This monitoring report summary of the calendar year is due to the DWQ Regional Office no later than March 15t of the following year. Facility Name: Fortress Wood Products, Inc., 899 Foreman Bundy Road, Elizabeth City, NC 27909 County: Pasquotank Phone Number; (252) 264-2466 Total number of SDOs monitored: 5 Outfall No. 1 Is this outfall currently in Tier Il (monitored monthly)? Yes [X] No a Was this outfall ever in Tier II (monitored monthly) in the past year? Yes [X] No 0 If this outfall was in Tier II for the last year, why was monthly monitoring discontinued? Enough consecutive samples below benchmarks to decrease frequency Q Received approval from DWQ to reduce monitoring frequency Other 0 Was this SDO monitored because of vehicle maintenance activities? Yes a No [X] _ Tier Two Totals Ramfall,m inches Parameter;;{un.ts} BOD5 {5 day} n COD, ; '� Ammonia Total IV�trogen ;.. Copper =totals recaverab e `; e TSS ..,e pW Benchmark N/A 30 120 7'.2 0.007 100 6-9 Date.Sample Collected,° Monthly 2.5 .241 943 Page 1 of 4 Storm Water Prevention Plan Fortress Wood Products, Inc. Elizabeth Ut , NC Outfall No. 2 Is this outfall currently in Tier II (monitored monthly)? Yes [X] No 0 Was this outfall ever in Tier II (monitored monthly) in the past year? Yes [X] No 0 If this outfall was in Tier II for the last year, why was monthly monitoring discontinued? Enough consecutive samples below benchmarks to decrease frequency Received approval from DWQ to reduce monitoring frequency Other 0 Was this SOO monitored because of vehicle maintenance activities? Yes 0 No [X] Parameter, 07nits) Ammoniaglum TierTotal( FVInch.eis day,) M NitrogenNon:Trout Benchmark N/A 30 120 7.2 0.007 100 6-9 Date Sample. Collected, 2/1112019 Monthly 2.5 .429 934 Outfall No. 3 Is this outfall currently in Tier II (monitored monthly)? Yes [X] No 0 Was this outfall ever in Tier it (monitored monthly) in the past year? Yes [X] No 0 If this outfall was in Tier II for the last year, why was monthly monitoring discontinued? Enough consecutive samples below benchmarks to decrease frequency 0 Received approval from DWQ to reduce monitoring frequency 0 Other 0 Was this SOO monitored because of vehicle maintenance activities? Yes 0 No [X] Page 2 of 4 Storm Water Prevention Plan Fortress Wood Products, Inc. LIizabeth Ut , NC: Outfall No.4 Is this outfall currently in Tier II (monitored monthly)? Yes [X] No p Was this outfall ever in Tier II (monitored monthly) in the past year? Yes [X] No p If this outfall was in Tier II for the last year, why was monthly monitoring discontinued? Enough consecutive samples below benchmarks to decrease frequency p Received approval from DWQ to reduce monitoring frequency Other Was this SDO monitored because of vehicle maintenance activities? Yes 0 No [X] Parameter, (units) Total Ammonia Copper Tier Two Rainfall, C4D Total total TiSS pH inches rBOD5y �5 dzy, l� 2gien recoverable NOn�'Trout Benchmark NIA 30 120 7.2.. .0.007 100 6-9 "Sample 84.6 Monthly 2.5 .435 Outfall No. 5 Is this outfall currently in Tier II {monitored monthly)? Yes [X] No 0 Was this outfall ever in Tier 11 (monitored monthly) in the past year? Yes [X] No a If this outfall was in Tier II for the last year, why was monthly monitoring discontinued? Enough consecutive samples below benchmarks to decrease frequency p Received approval from DWQ to reduce monitoring frequency Other Was this SDO monitored because of vehicle maintenance activities? Yes n No [X] Parameter, (units} Total Ammonia Tier Two Rainfall, Inches BOD5 G[iD day) Total Nitrogen Copper total TSS pH (5 recoverable Non:.Trout Benchmark NIA 30 120` 7.2 .0.007 .100 6-9 Date Sample Collec� t dr a �' 7131l2018 Monthly 2.5 .290 19 Page 3 of 4 "I certify under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." Responsible Official Signature: Printed Name: Ken McBride Title: _ Director of Manufacturing_ Date: 2/28/2019 Page 4 of 4 0 Storm Water Prevention Plan Fortress Wood Products, Inc. Elizabeth City, NC STORM WATER DISCHARGE OUTFALL (SDO) SUMMARY DATA MONITORING REPORT (DMR) RECEIVED Calendar Year 2018 FEB 26 2019 Individual NPDES Permit No. NCS000008 or CENTRAL FILES Certificate of Coverage (COC) No. NCG DWR SECTION This monitoring report summary of the calendar year is due to the DWQ Regional Office no later than March 114 of the following year. Facility Name: Fortress Wood Products, Inc., 899 Foreman Bundy Road, Elizabeth City, NC 27909 County: Pasquotank Phone Number: (252) 264-2466 Total number of SDOs monitored: 5 Outfall No. 1 Is this outfall currently in Tier II (monitored monthly)? Yes [X] No Was this outfall ever in Tier II (monitored monthly) in the past year? Yes [X] No [] If this outfall was in Tier II for the last year, why was monthly monitoring discontinued? Enough consecutive samples below benchmarks to decrease frequency 0 Received approval from DWQ to reduce monitoring frequency p Other a Was this SDO monitored because of vehicle maintenance activities? Yes o No [X] Parameter, (units) Ammonia Copper Total Semi Annual Rainfall, BADS Total Inches (g day) COD Nitrogen total TSS pH Non -Trout recoverable Benchmark NIA 1 30 1 120 7.2 0.007 100 6-9 Date Sample Collected, 1114/2019 Semi-Annua 2.0 4.94 28 2.02 .399 107 6.78 Page 1 of 4 Storm Water Prevention Plan Fortress Wood Products, Inc. Elizabeth City, NC Outfall No. 2 Is this outfall currently in Tier II (monitored monthly)? Yes [X] No a Was this outfall ever in Tier II (monitored monthly) in the past year? Yes [X] No a If this outfall was in Tier 11 for the last year, why was monthly monitoring discontinued? Enough consecutive samples below benchmarks to decrease frequency . a Received approval from DWQ to reduce monitoring frequency Other p Was this SDO monitored because of vehicle maintenance activities? Yes o No [X] Semi Annual Total Rainfall, Inches Parameter, (units) BOD5 '(5 day) COD Ammonia Total Nitrogen Non -Trout Copper total recoverable T5S pH Benchmark NIA 30 120 7.2 0.007 100 6-9 Date Sample Collected, 1/1412019 Semi -Annual 2.0 2.56 30 1.73 .042 17.5 6.95 Outfall No. 3 Is this outfall currently in Tier II (monitored monthly)? Yes [X] No 0 Was this outfall ever in Tier II (monitored monthly) in the past year? Yes [X] No [] If this outfall was in Fier 11 for the last year, why was monthly monitoring discontinued? Enough consecutive samples below benchmarks to decrease frequency Q Received approval from DWQ to reduce monitoring frequency Other Was this SDO monitored because of vehicle maintenance activities? Yes p No [X] Parameter, (units) Ammonia Copper Total Semi Annual Rainfall, BODS Total Inches (5 day) COD Nitrogen total TSS pH (Non-Trout) recoverable Benchmark NIA 30 120 7.2 0.007 100 6-9 Date Sample Collected, 1/14/2019 Semi -Annual 2.0 4.70 26 1.82 .786 114 7.49 Page 2 of 4 Storm Wafer Prevention Plan Fortress Wood Products, Inc. Elizabeth City, NC Outfall No. 4 Is this outfall currently in Tier 11 (monitored monthly)? Yes [X] No a Was this outfall ever in Tier Il (monitored monthly) in the past year? Yes [X] No a If this outfall was in Tier 11 for the last year, why was monthly monitoring discontinued? Enough consecutive samples below benchmarks to decrease frequency 0 Received approval from DWQ to reduce monitoring frequency o Other a Was this SDO monitored because of vehicle maintenance activities? Yes a No [X] Parameter, (units) Ammonia Copper Total Semi Annual Rainfall, BOD5 Total Inches (5 day) COD Nitrogen " total .TSS pH Non -Trout recoverable Benchmark NIA 30 120 7.2 0.007 100 6-9 Date Sample Collected, 1/14/2019 Semi -Annual 2.0 2.84 37 3,33 .172 122 6.12 Outfall No. 5 Is this outfall currently in Tier II (monitored monthly)? Yes [X] No p Was this outfall ever in Tier 11 (monitored monthly) in the past year? Yes [X] No 0 If this outfall was in Tier II for the last year, why was monthly monitoring discontinued? Enough consecutive samples below benchmarks to decrease frequency 0 Received approval from DWQ to reduce monitoring frequency 0 Other p Was this SDO monitored because of vehicle maintenance activities? Yes a No [X] Semi Annual Total Rainfall, Inches Parameter, (units) BODS (5 day) COD Ammonia Total Nitrogen Non -Trout Copper total recoverable TSS pH Benchmark N/A 30 120 7.2 0.007 100 6-9 Date Sample Collected, 1/14/2019 Semi -Annual 2.0 2.08 28 3.36 .109 95.8 6.16 Page 3 of 4 I certify under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." Responsible Official Signature: Printed Name: Ken McBride Title: Director of Manufacturing Date: 1/31/2019 Page 4 of 4