Loading...
HomeMy WebLinkAboutNCGNE1106_COMPLETE FILE - HISTORICAL_20180814STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. NCGNE b�P DOC TYPE HISTORICAL FILE DOC DATE ❑ 00 YYYYMMDD ROY COOPER Governor � 1 `.5r. A y Energy, Mineral and Land Resources ENVIRONMENTAL QUALITY August 14, 2018 Snap-On Power Tools Inc. Attn: Joe Wilson, Safety Manager Post Office Box 1596 — - _. ------Murphy, North Carolina-28906 Subject: No Exposure Certification — Approval NCGNEI 106 Snap-On Power Tools, Inc Cherokee County, North Carolina Dear Mr. Wilson: MICHAEL S. REGAN Secretary WILLIAM E. VINSON, JR. Interim Director The Division has reviewed your application for a No Exposure Certification for Exclusion (NE) for the subject facility. Based on the information provided and a site visit conducted on August 9, 2018, the NE has been approved. Please note that you are obligated to maintain no -exposure conditions at your facility. If conditions change such that your facility can no longer qualify for a NE, you are obligated to immediately obtain NPDES permit coverage for your stornwater discharge. Otherwise, the discharge becomes subject to enforcement as an un-permitted discharge. Your NE does not expire. In order to help assure that your facility stays in compliance with all of the conditions in the Certification, you must self -recertify your facility at least annually. Please see the attachment for information on self - recertification. Your conditional exclusion from permitting does not affect your facility's legal requirements to obtain environmental permits that may be required under other federal, state, or local regulations or ordinances. If you have any questions or need further information, please contact Isaiah Reed at (828) 296-4500. Sincerely, for William E. inson, Jr. Interim Director Enclosure: inspection report cc: Bethany Georgouiias, Environmental Engineer, Stornwater Program, bethany.geor otg, ilias cr,ncdenr. State or North Carolina I Environmental Quality I energy, Mineral and Land Resources 2090 US 70 Highway I Swammnoa, NC 28778-821 I 828 296 4500 T E Permit: NCGNE1106 SOC: County: Cherokee Region: Asheville Compliance Inspection Report Effective: 09/14/17 Expiration Effective: Expiration Owner: Snap -on Power Tools Inc Facility: Snap-On Power Tools, Inc. 250 Snapon Dr Murphy NC 28906 Contact Person: Joe Wilson Title: Phone: 828-835-4407 Directions to Facility: From Asheville, NC take 40W, take exit 27 to US-74. Continue on US-74 for approximately 84 miles. Turn left on Snap-On Drive. System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection date: 08/0912018 EntryTime: 10:OOAM Exit Time: 11:00AM Primary Inspector: Isaiah L Reed Phone: 828-296-4614 Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Stormwater Discharge, No Exposure Certificate Facility Status: EE Compliant ❑ Not Compliant Question Areas: ® Miscellaneous Questions ® Misc (See attachment summary) Page: 1 0 0 Permit: NCGNE1106 Owner -Facility: Snap -on Power Tools Inc Inspection Date: 08/0912018 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: On August 9, 2018 this facility was inspected for compliance. I met with Joe Wilson on site. During the inspection the follwing was noted: One secondary containment structure drain valve was not locked. THe site contact indicated that this issue would be corrected as soon as possible. The Division has reviewed your application for a No Exposure Certification for Exclusion (NE) for the subject facility. Based on the information provided and a site visit conducted on August 9, 2018, the NE has been approved. Please note that you are obligated to maintain no -exposure conditions at your facility. If conditions change such that your - -facility can no longer'qualify fora NE, you are obligated to immediately obtain NPDES permit coverage for your stormwa6ir - discharge. Otherwise, the discharge becomes subject to enforcement as an un-permitted discharge. Your NE does not expire. In order to help assure that your facility stays in compliance with all of the conditions in the Certification, you must self -recertify your facility at least annually. Please see the attachment for information on self -recertification. Your conditional exclusion from permitting does not affect your facility's legal requirements to obtain environmental permits that may be required under other federal, state, or local regulations or ordinances. If you have any questions or need further information, please contact Isaiah Reed at (828) 296-4500. Page: 2 h Permit: NCGNE1106 Owner - Facility: Snap -on Power Tools Inc Inspection Date: 0810912018 Inspection Type : Compliance Evaluation Misc Is the facility compliant? Comment: Reason for Visit: Routine Yes No NA NE 0 ❑ ❑ ❑ Page: 3 0 e* Permit: NCGNE1106 SOC: County: Cherokee Region: Asheville Compliance Inspection Report Effective: 09114117 Expiration: Effective: Expiration: Owner: Snap -on Power Tools Inc Facility: Snap-Qn Power Tools, Inc. 250 Snapon Dr Murphy NC 28906 Contact Person: Joe Wilson Title: Phone: 828-835-4407 Directions to Facility: From Asheville, NC take 40W, take exit 27 to US-74. Continue on US-74 for approximately 84 miles. Turn left on Snap-On Drive. System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Re prosentative(s): Related Permits: Inspection Date: 0810912018 EntryTime: 10:OOAM Exit Time: 11:OOAM Primary Inspector: Isaiah L Reed Phone: 828-296-4614 Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Stormwater Discharge, No Exposure Certificate Facility Status: N Compliant n Not Compliant Question Areas: Miscellaneous Questions Misc (See attachment summary) Page: 1 L Permit: NCGNE1106 Owner - Facility: Snap on Power Tools Inc Inspection Date: 0810912018 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: On August 9, 2018 this facility was inspected for compliance. I met with Joe Wilson on site. During the inspection the follwing was noted: One secondary containment structure drain valve was not locked. THe site contact indicated that this issue would be corrected as soon as possible. The Division has reviewed your application for a No Exposure Certification for Exclusion (NE) for the subject facility. Based on the information provided and a site visit conducted on August 9, 2018, the NE has been approved. Please note that you are obligated to maintain no -exposure conditions at your facility. If conditions change such that your facility can no longer qualify for a NE, you are obligated to immediately obtain NPDES permit coverage for your stormwater discharge. Otherwise, the discharge becomes subject to enforcement as an un-permitted discharge. Your NE does not expire. In order to help assure that your facility stays in compliance with all of the conditions in the Certification, you must self -recertify your facility at least annually. Please see the attachment for information on self -recertification. Your conditional exclusion from permitting does not affect your facility's legal requirements to obtain environmental permits that may be required under other federal, state, or local regulations or ordinances. If you have any questions or need further information, please contact Isaiah Reed at (828) 296-4500. Page: 2 Permit: NCGNE1106 Owner -Facility; Snap -on Power Tools Inc Inspection Date: 08109/2018 Inspection Type : Compliance Evaluation Reason for Visit: Routine Misc Is the facility compliant? Comment: Yes No NA NE ❑ ❑ ❑ Page: 3 0 Facility Name: Permit#: Time in/out: Date: Stormwater Pollution Prevention Plan Does the site have:a SWPPP? Does the Plan include a General Location (USGS) map? Does the Plan include a "Narrative Description of Practices"? Does the Plan include a detailed site map including outfall locations and drainage areas? 'Does the Plan include a list of significant spills occurring during the past 3 years? Has the facility evaluated feasible alternatives to current practices? Does the facility provide all necessary secondary containment? Does the Plan include a BMP summary? :Does the Plan include a Spill Prevention and Response Plan (SPRP)?f Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? 'Does the facility provide=and document Employee Training? Does the Plan include a list of Responsible Party(s)? ]s the Plan feviewed and rupdated annually? Does the Plan include a 5tormwater Facility Inspection Program? IHas the StormwaterPoilutionPrevention Plan been implemented? 'omments Energy Mineral and l,ondllesnurces �N VIRO NMCNTnL �guna 1 Yes No NA 7 _ D. M Qualitative Monitoring Yes ,Has the facility conducted,its Qualitative monitoring semi-annually? n :omments NE No fkA NE IAnalytical Monitoring I Yes No Has the facility conducted,its,Analytical monitoring? Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? :omments F) N Permit and Outfalls Yes No NA NE 'Is a-copy,of the Permit and the'Certificate of Coverage available at this'site? A Were all outfalls observed during the inspection? — If the facility has representative outfall status, is.it properly documented by the Division? Has the facility evaluated all illicit (non Stormwater) discharges? :omments and Others Present: Alexander, Laura From: Kucken, Darlene Sent: Thursday, August 10, 2017 4:33 PM To: Ge Bethany; Alexander, Laura Subject: CGNE110 nap -On Power Tools - Murphy Follow Up Flag: Follow up Flag Status: Flagged I met with Joe Wilson, Safety Manager, at the above noted facility in response to a request for a NEC. Everything at this facility is either indoors or under cover. All water generated within the facility is treated in the onsite WWTP and then sent to the public wastewater plant in Murphy. The facility is swept and wet mopped daily and all materials are stored in closed containers for recycling. The place is very clean inside and out. I suggest they be granted the NEC. Darlene Kucken - Darlene.Kucken@ncdenr.gov North Carolina Dept. of Environmental Quality Asheville Regional Office Division of Energy, Mineral, and Land Resources 2090 U.S. 70 Highway Swannanoa, NC 28778 Tel: 828-296-4S00 Fax: 828-299-7043 E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. `,A Go Green! Print this email only when necessary. Thank you for helping NCDENR be environmentally responsible. 1 Kucken, Darlene From: Kucken, Darlene Sent: Thursday, August 10, 2017 4:33 PM To: Bethany Georgoulias (bethany.georgoulias@ncdenr.gov); Laura Alexander (laura.alexander@ ncdenr.gov) Subject: NCGNE1106 Snap-On Power Tools - Murphy I met with Joe Wilson, Safety Manager, at the above noted facility in response to a request for a NEC. Everything at this facility is either indoors or under cover. All water generated within the facility is treated in the onsite WWTP and then sent to the public wastewater plant in Murphy. The facility is swept and wet mopped daily and all materials are stored in closed containers for recycling. The place is very clean inside and out. I suggest they be granted the NEC. Darlene Kucken - Darlene.Kucken@ncdenr.gov North Carolina Dept. of Environmental Quality Asheville Regional Office Division of Energy, Mineral, and Land Resources 2090 U.S. 70 Highway Swannanoa, NC 28778 Tel: 828-296-4500 Fax: 828-299-7043 E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. AGo Green! Print this email only when necessary. Thank you for helping NCDENR be environmentally responsible. �� noAs-(2- 44� *1 � 0 rC('n6)--j of ou Energy. Mineral and Land Resources ENVIRONMENTAL QUALITY Division of Energy, Mineral and Land Resources Land Quality Section National Pollutant Discharge Elimination System NO EXPOSURE CERTIFICATION for Exclusion NCGNEQ000 FOR A(ILNCY USE ONLY Date Reccived Ycar :Nnnth I Day Cenilicate ofcovmagc NCGN I I' FEB 2 z 2017 National Pollutant Discharge Elimination System application for exclusion from a Stormwater Permit based on NO EXPOSURE: Submission of this No Exposure Certification constitutes notification that your facility does not require a permit for stormwater discharges associated with industrial activity in the State of North Carolina because it qualifies for a no exposure exclusion. A condition of no exposure at an industrial facility means all industrial materials and activities are protected by a storm resistant shelter (with some exceptions) to prevent exposure to rain, snow, snowmelt, and/or runoff. For permitted facilities in North Carolina, DEMLR must approve your application for No Exposure Certification before this exclusion is effective. Until you are issued a No Exposure Certification and your NPDES permit is rescinded, your facility must continue to abide by the terms and conditions of the current permit. Industrial materials or activities include, but are not limited to: material handling equipment or activities, industrial machinery, raw materials, intermediate products, by-products, final products, or waste products. Material handling activities include the storage, loading and unloading, transportation, or conveyance of any raw material, intermediate product, final product or waste product. A storm resistant shelter is not required for the following industrial materials and activities: drums, barrels, tanks, and similar containers that are tightly sealed, provided those containers are not deteriorated and do not leak. "Sealed" means banded or otherwise secured and with locked or non -operational taps or valves; adequately maintained vehicles used in material handling; and final products, other than products that would be mobilized in stormwater discharges (e.g., rock salt). A No Exposure Certification must be provided for each facility qualifying for the no exposure exclusion. In addition, the exclusion from NPDES permitting is available on a facility -wide basis only —not for individual outfalls. If any industrial activities or materials are, or will be, exposed to precipitation, the facility is not eligible for the no exposure exclusion. By signing and submitting this No Exposure Certification form, you certify that a condition of no exposure exists at this facility or site and are obligated to comply with the terms and conditions of 40 CFR 122.26(g). If approved, your conditional No Exposure Exclusion has no expiration date BUT MUST BE self re -certified at least annually. Please look for information about re -certification under the No Exposure section on this page: https:Ildeg. nc.gov/about/divisionsieneMy-mineral-land-resources/energy-mineral-land-12ermitsistormwater- S permits/npdes-industrial-sw Pbtl 1ueitidtij7please contact the DEMLR Regional Office for your area. (See page 6) 1 CEi`!R-LAND 4Up,�i�'; (Please print or type) KeCelved 1) Mailing address of-ow,nerloperator (address to which all certification correspondence will be mailed): Name v5►,a 11ki PO4✓'Pr TyaL" r>7c-., FEB 2 8 2017 Contact 3n0 it/+jSvh Street Address City Telephone No. �I r V State - D 7 Fax: Land Quality S ZIP Code 'J-F f 06-heville 3a�- S35 - 966 n SWU-NCGNE Page 1 of 7 Last revised W2812016 C 1 (0 NCGNE0000 No Exposure Certification 2) Location of facility producing discharge: Facility Name 5i ,q Facility Contact ' pro Street Address 256 City County4'Z16 dap, Telephone No. 'N8 - 8 3S - (v035 Fax: 3) Physical location information: T94L 1,ye. State A/C ZIP Code 35 - Please provide a narrative description of how to get to the facility (use street names, state road numbers, and distance and direction from a roadway intersection). 61" s W. e . ✓ r' 'ru Kv 40 Ll (A copy of a map with the facility clearly located on it should be included with the certiff9tion application) 4) Is the facility located on Native American Lands? ❑ Yes V/No J, PO-1 5) Is this a Federal facility? ❑ Yes O No 6) Latitude 35, ll.119 % Longitude 'aq.OU13.2,7 (deg., min., seconds) 7) This NPDES No Exposure Exclusion application applies to which of the following: ❑ New or Proposed Facility V Existing Date operation is to begin Date operation began 260,2 ❑ Renewal of existing No Exposure Certification Certification No.: NCGNE 8) Was this facility or site ever covered under an NPDES Stormwater Permit? ❑ Yes ❑ No If yes, what is the NPDES Permit Number? 9) Standard Industrial Classification: Provide the 4-digit Standard Industrial Classification Code (SIC Code) that describes the primary industrial activity at this facility SIC Code: `3 3 1 6 10) Provide brief description of the types of industrial activities and products produced at this facility: 101nd,xr. Of C' 111 /ISC d' i7hPLlrliiyiL_ Awpd-1als . JJ4Q I"'4Vd,C .1`,264"' f 11) Does this facility have any Non -Discharge permits (ex: recycle permits)? "o ❑ Yes If yes, list the permit numbers for all current Non -Discharge permits for this facility: Page 2of7 -� SW U-NCGNE ; _-.Last'revised.9M/2016 NCGNE0000 No Exposure Certification Exposure Checklists (12. - 14.) 12) Are any of the following materials or activities exposed to precipitation, now or in the foreseeable future? (Please check either "Yes" or "No.") If you answer "Yes" to any of these items, you are not eligible for the no exposure exclusion. a. Using, storing, or cleaning industrial machinery or equipment, and areas where ❑ Yes ZNo ❑ NIA residuals from using, storing or cleaning industrial machinery or equipment remain and are exposed to stormwater b. Materials or residuals on the ground or in stormwater inlets from spills/leaks ❑ Yes V No ❑ NIA c. Materials or products from past industrial activity ❑ Yes G� No ❑ NIA d. Material handling equipment (except adequately maintained vehicles) ❑ Yes iNo ❑ NIA e. Materials or products during loading/unloading or transporting activities ❑ Yes 1"o ❑ NIA f. Materials or products stored outdoors (except final products intended for outside ❑ Yes NrNo ❑ NIA use [e.g., new cars] where exposure to stormwater does not result in the discharge of pollutants) g. Materials contained in open, deteriorated or leaking storage drums, barrels, ❑ Yes V�No Q NIA tanks, and similar containers h. Materials or products handled/stored on roads or railways owned or maintained ❑ Yes A ❑ NIA by the discharger i. Waste material (except waste in covered, non -leaking containers [e.g., ❑ Yes Q/No ❑ NIA dumpsters)) j. Application or disposal of process wastewater (unless otherwise permitted) ❑ Yes ?!/No © NIA k. Particulate matter or visible deposits of residuals from roof stacks and/or vents ❑ Yes [VNo © NIA not otherwise regulated (i.e., under an air quality control permit) and evident in the stormwater outflow I. Empty containers that previously contained materials that are not properly stored ❑ Yes dNo ❑ NIA (i.e., not closed and stored upside down to prevent precipitation accumulation) m. For any exterior ASTs, as well as drums, barrels, tanks, and similar containers ❑ Yes I/No ❑ NIA stored outside, has the facility had any releases in the past three (3) years? 13) Above Ground Storage Tanks (ASTs): If you answer "No" to any of the following items, you are not eligible for the no exposure exclusion. a. Are exterior ASTs or piping free of rust, damaged or weathered coating, pits, or 5/Yes ❑ No ❑ NIA deterioration, or evidence of leaks? b. Is secondary containment provided for all exterior ASTs? If so, is it free of any [Yes ❑ No ❑ NIA cracks, holes, or evidence of leaks, and are drain valves maintained locked shut? 14) Secondary Containment: If you answer "No" to any of the following items, you are not eligible for the no exposure exclusion. Page 3 of 7_ 5WU-NCGNE Last revised;912812016 NCGNE0000 No Exposure Certification a. Is secondary containment provided for single above ground storage containers VYes ❑ No ❑ NIA (including drums, barrels, etc.) with a capacity of more than 660-gallons? b. Is secondary containment provided for above ground storage containers stored VYes ❑ No ❑ NIA in close proximity to each other with a combined capacity of more than 1,320- gallons? c. Is secondary containment provided for Title III Section 313 Super -fund M/Yes ❑ No ❑ NIA Amendments and Reauthorization Act (SARA) water priority chemicals"? d. Is secondary containment provided for hazardous substances" designated in dyes ❑ No ❑ NIA 40 CFR §116? e. Are release valves on all secondary containment structures locked? VYes ❑ No ❑ NIA 15) Hazardous Waste: a. Is this facility a Hazardous Waste Treatment, Storage, or Disposal Facility? ❑ Yes VNo ❑ NIA b. Is this facility a Small Quantity Generator (less than 1000 kg. of hazardous ❑ Yes NrNo ❑ NIA waste generated per month) of hazardous waste? c. Is this facility a Large Quantity Generator (1000 kg. or more of hazardous waste ❑ Yes YNo ❑ NIA generated per month) of hazardous waste? If you answered yes to questions b. or c., please provide the following information: Type(s) of waste: vendor: How is material stored: Where is material stored: How many disposal shipments per year: Name of transport 1 disposal Vendor address: Footnotes to Questions 14) c. & d. 'Note that amounts below the 660-gallon (single) and 1,320-gallon (combined) bulk storage minimums require secondary containment. However, some exceptions may be made for de minimis amounts of certain substances, andlor other qualifiers, as described in the exemptions from reporting requirements of Title III SARA 313 in 40 CFR §372.38. *"Note that amounts below the 660-gallon (single) and 1,320-gallon (combined) bulk storage minimums require secondary containment. However, some exceptions may be made for amounts less than the Reportable Quantities of the hazardous substances listed in 40 CFR §117.3. 16) Other information: If you answer "Yes" to any of the following items, you might not be eligible for the no exposure exclusion. A more in-depth evaluation of the site circumstances may be required. Page 4 of 7 SWU-NCGNE Last revised 9/28/2016 NCGNEOOOO No Exposure Certification a. Does your facility store used, recycled, or otherwise reclaimed pallets outside? ❑ Yes VNo ❑ NIA b. Does your facility have coal piles on site? © Yes VNo ❑ NIA c. Does your facility store other fuel sources outside in piles, such as wood chips, ❑ Yes [VNo 0 NIA sawdust, etc.? d. Does your facility have air emissions associated with its industrial activity (e.g., 141Yes ❑ No ❑ NIA degreasing operations, plating, painting and metal finishin )? If so, describe the industrial activity: IuLK (�x;l.�e%oLi�� _.�e� �y/n�c��� Coot tv"'"� e. If you answered yes to d., are those emissions permitted by an Air Quality ❑ Yes No ❑ NIA Permit? Please specify: f. Please list any other environmental program permits (federal, state, etc.) not specified earlier in this application (such as Hazardous Waste Permits, etc.): Permit: Program: Permit: Program: Permit: Program: Permit: Program: Permit: Program: Permit: Program: Permit: Program: Page 5 of 7 SWU-NCGNE Last revised 9/28/2016 NCGNE0000 No Exposure Certification 17) Certification: I certify under penalty of law that I have read and understand the eligibility requirements for claiming a condition of "no exposure" and obtaining an exclusion from NPDES stormwater permitting. I certify under penalty of law that there are no discharges of stormwater contaminated by exposure to industrial activities or materials from the industrial facility or site identified in this document (except as allowed under 40 CFR 122.26(g)(2)). understand that I am obligated to maintain no exposure conditions and complete a Self -Recertification form at least once each year, and if requested, provide this certification to the operator of the local municipal separate storm sewer system (MS4) into which the facility discharges (where applicable). I understand that I must allow the North Carolina Division of Energy, Mineral, and Land Resources, or MS4 operator where the discharge is into the local MS4, to perform inspections to confirm the condition of no exposure and to make such inspection reports publicly available upon request. I understand I must keep a copy of annual re -certifications on file at the facility. In the event that the site no longer qualifies for a No Exposure Exclusion, I understand that I must obtain coverage under an NPDES permit prior to any point source discharge of stormwater from the facility. Additionally. I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is to the best of my knowledge and belief true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations. certify that I am familiar with the information contained in this application and that to the best of my knowledge and belief such information is true, complete, and accurate. Printed Name of Person Signing: �p(> W1 rso� _ Title: 7 {Signatur Applicant} (Date Signed) Please note: This application for the No Exposure Exclusion is subject to approval by the NCDEQ Regional Office prior to issuance. The Regional Office may inspect your facility for compliance with no exposure conditions prior to that approval. The Regional Office may also inspect your facility at any time in the future for compliance with the No Exposure Exclusion. North Carolina General Statute 143-215.6 B(i) provides that: Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan, or other document filed or required to be maintained under this Article or a rule implementing this Article; or who knowingly makes a false statement of a material fact in a rulemaking proceeding or contested case under this Article; or who falsifies, tampers with, or knowingly renders inaccurate any recording or mon4oring device or method required to be operated or maintained under this Article or rules of the [Environmental Management] Commission implementing this Article shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed ten thousand dollars ($10.000). There is currently no fee for a No Exposure Exclusion. Page 6 of 7 SWU-NCGNE Last revised 9128/2016 NCGNE0000 No Exposure Certification Final Checklist This application should include the following items: BK This completed application and all supporting documentation. �j A map with the location of the facility clearly marked. d If the site currently has an NPDES Stormwater Permit, be sure to indicate the permit number in Question B. Mail the entire package to: Stormwater Permitting Program Division of Energy, Mineral and Land Resources 1612 Mail Service Center Raleigh, North Carolina 27699-1612 Note The submission of this document does not guarantee the issuance of a No Exposure Exclusion. For questions, please contact the DEMLR Regional Office for your area. DEMLR Regional Office Contact Information: Asheville Office ...... (828) 296-4500 Fayetteville Office ... (910) 433-3300 Mooresville Office ... (704) 663-1699 Raleigh Office ........ (919) 791-4200 Washington Office ...(252) 946-6481 Wilmington Office ... (910) 796-7215 Winston-Salem ...... (336) 776-9800 Central Office .........(919) 707-9220 Page 7 of 7 SWU-NCGNE Last revised 912812016 12/16/2015 sheville, NC to 250 Snap On Dr, Murphy, NC 28906 - Maps a Google Maps Asheville, NC to 250 Snap On Dr, Murphy, Drive 108 miles, 1 h 56 min NC 28906 0 Asheville, NC Follow 1-40 W and US-74 W to Loin Rd in Murphy 1 h 57 min (108 mi) t 1. Head east on S Pack Square 154 ft d 41 2. Turn left onto N Pack Square 289 ft N 3. Turn right onto Broadway 0.3 mi 4. Slight right onto the Interstate 240 W/U.S. 70 W ramp to U.S. 74 Alternante 5. Merge onto 1-240 W/US-70 W 0 Continue to follow 1-240 W n 0.2 mi 1.5mi y mac# Wood P�° Map data 02015 Google 100 ft , httpsi/ www.googl e.com/maps/di r/Ashevi Ile,+N C[250+Snap+On+D r,+M urphy,+NC+289M@35.1149768,-84.0037303,18z/am=tldata=!4m 13!4m 1211 m5! 1 m l!... 1/3 Asheville, NC to 250 Snap On Dr, Murphy, NC 28906 - G le Maps 6. Keep right at the fork Ontinue on 1-240 W/1-26 E, follow signs for Interstate 240 W/Interstate 26 E/Interstate 40 3.2 mi 7. Take exit 31 B to merge onto 1-40 W toward Canton/Knoxville 18.3 mi 8. Use the right 2 lanes to take exit 27 for US-74 toward US-19/US- 23/Clyde/Waynesville/Maggie Val ley/Franklin/M urphy/Atlanta 0.3 mi t 9. Continue onto US-74 W/Great Smoky Mountains Expy 33.3 mi h 10. Keep left to continue on US-74 W 5C.6 mi Drive to State Rd 1624 59 s (0.3 m) 41 11. Turn left onto 6EwiH 400 ft t' 12. Slight right onto State R4-1-624 f"r O- 0'0()✓( 0.2 mi 250 Snap On Dr Murphy, NC 28906 These directions are for planning purposes only. You may find that construction projects, traffic, weather, or other events may cause conditions to differ from the map results, and you should plan your route accordingly. You must obey all signs or notices regarding your route. 0 https:llwww.googio.com/m apsldir/Ashevi II e,+N C1250+Snap+On+p r,+M urphy,+NC+289061@35.1149768,-84.0037303,18z1am=tldata=!4m 13!4m 12! 1m 5! 1 m 1 !... 213