Loading...
HomeMy WebLinkAboutNCG210355_MONITORING INFO_20190203V S1Z, 0 STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. DOC TYPE ❑HISTORICAL FILE ❑ MONITORING REPORTS DOC DATE ❑ � � 0 L) YYYYMMDD Certified Mail — 7017 0660 0001 0015 3779 Return Receipt Requested January 16, 2020 Central Files NCDEQ - DWR 1617 Mail Service Center Raleigh, NC 27699-1617 RE: Stormwater Sampling — December 2019 Permit No. NCG21355 Louisiana-Pacific Corporation To Whom It May Concern, RECEIVED FEB 0 3 2019 d- E�,LEI ..... ... ..-�-ram• Please find attached two copies of the Stormwater Discharge Outfall Monitoring Report for outfalls 001, 002, 003, 004, 005, and 006 as required General Permit No NCG210355. Please note that due to past results for outfalls 1-3, we fall under Tier IUTIER III requirements and will be submitting reports monthly. Outfalls 004, 005, and 006 are on a semi-annual sampling schedule and were sampled in December 2019. If there are any questions regarding this report, please contact me at (336) 696-3341. Sincerely, Michael Rhea, CSP 6HS Manager Louisiana Pacific - Roaring River Michael. rhea@lpcorp.com (336) 696-3341 cc: File ADDRESS 1068 ABTCO Road North Wilkesboro, NC 28659 TEL 336.696.2751 FAX 336.696.3443 WEB www.lpcorp.com Semi-annual Stormwater Discharge Monitoring Report for North Carolina DEMLR General Permit No. NCG210000 Date submitted 1/16/2020 CERTIFICATE OF COVERAGE NO. NCG21355 FACILITY NAME Louisiana-Pacific, Roaring River_ COUNTY Wilkes PERSON COLLECTING SAMPLES Mike Jolly LABORATORY LP Lab Cert. # 145 Comments on sample collection or analysis: SAMPLE COLLECTION YEAR 2019 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ❑ Monthly'_ December (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flaw ❑Water Supply [:]SA ®Other: Yadkin River Class C PLEASE REMEMBER TO SIGN ON THE REVERSE 4 Part A: Stormwater Benchmarks and Monitoring Results (Monitoring is required only if the facility stores exposed accumulations of sawdust, wood chips, bark, mulch, or other similar material on site for longer than seven (7) days.) No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches' Chemical Oxygen Demand Total Suspended Solids Benchmarks ===> - - 120 mg/L 100 mg/L or 50 mg/L4 001 12/9/2019 0.23 138 mg/L 139 mg/L 002 12/9/2019 0.23 214 mg/L 119 mg/L 003 12/9/2019 0.23 132 mg/L 138 mg/L 004 12/13/2019 0.56 100 mg/L 36 mg/L 005 12/13/2019 0.56 93 mg/L 213 mg/L 006 12/13/2019 0.56 64 mg/L 64 mg/L arameter at th 1 Monthly sampling (instead of semi-annual) snnuai must begin with th second consecutive benchmark for same ) g t e onsecut e e e p e same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit text, Table 3, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Note: Results must be reported in numerical format. For example, do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non - numerical format. When results are below the applicable limits, the must be reported in the format "<XX m L" where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. Permit Date: 8/1/2013-7/31/2018 SWU-245, last revised 7/31/2013 Page 1 of 2 ❑ No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches' Non -polar O&G by EPA 1664 (SGT-HEM) Total Suspended Solids Benchmarks ===> - - 15 mg/L 100 mg/L or 50 mg/L4 Footnotes from Part A also apply to this Part B Note: 1f you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART 11 SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ® NO IF YES, HAVE YOU CONTACTED THE DEMLR REGIONAL OFFICE? YES ® NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an oriqinal and one copv of this DMR, includinq all "No Discharge" reports, within 30 days of receipt of the lab results (or at end of monitorina period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) (Date)'/16/2020 SWU-245, last revised 7/31/2013 Page 2 of 2 Permit Date: 8/1/2013-7/31/2018