Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NCG140463_COMPLETE FILE - HISTORICAL_20180924
STORMWATfR DIVISION CODING SHEET NCG PERMITS PERMIT NO. /vIqD��3 DOC TYPE tl-'HISTORICALFILE ❑ MONITORING REPORTS DOC DATE ❑ j d) v D YYYYMMDD Permit Number NCG140463 Central Files: APS _ SWP 9/21/2018 Permit Tracking Slip Program Category Status Project Type NPDES SW Active New Project Permit Type Version Permit Classification Ready Mix Concrete StormwaterlWastewater Discharge COC 1.00 COC Primary Reviewer Permit Contact Affiliation Bethany.Georgoulias Coastal SWRule Permitted Flow RECF IvED Facility SEP.2 4 .2018 Facility Name CENTRAL~ FILES MajorlMinor Region Raleigh Concrete ©WR SECTION Minor Raleigh Location Address County 1938 S Wilmington St Wake Facility Contact Affiliation Raleigh NC 27603 Brenda Roque 1938 S Wilmington St Owner Raleigh NC 27603 Owner Name Owner Type Raleigh Concrete LLC Non -Government Owner Affiliation Jose Juan Plascencia Sanchez 1938 S Wilmington St Dates/Events Raleigh NC 27603 Scheduled Orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 9/21 /2018 6/26/2018 9121 /2018 9/21/2018 6/30/2022 Regulated Activities Requested /Received Events Concrete products manufacture RO staff report received 813118 RO staff report requested 713118 Outfall 001 Waterbody Name Streamindex Number Current Class Subbasin Walnut Creek 27-34-(4) C;NSW 03-04-02 V ROY COOPER NORTH CAROLINA Governor Environmental Quality MICHAEL S. REGAN Secretary WILLIAM E. (TOBY) VINSON, JR. Interim 01rector September 21, 2018 Jose Juan Sanchez Raleigh Concrete, LLC 1938 South Wilmington Street Raleigh, NC 27603 Subject: General Permit No. NCG020000 Raleigh Concrete COC NCG140463 Wake County Dear Mr. SAnehez: In accordance with your application for a discharge permit received on June 26, 2018, we are forwarding herewith the subject Certificate of Coverage (COC) to discharge under the subject state — NPDES general permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection Agency dated October 15, 2007 (or as subsequently amended). Please take notice that this certificate of coverage is not transferable except after notice to the Division of Energy, Mineral, and Land Resources. The Division may require modification or revocation and reissuance of the certificate of coverage. This general permit allows the discharge of stonmwater and certain types of wastewater. However, your application specified that no wastewater would be discharged from this facility. Therefore, the COC allows stormwater discharges only. Per the requirements of the Neuse Riparian Buffer Rule, all stormwater drainage to stream buffers, from portions of this site that have been constructed after July 22, 1997, must be discharged through a correctly designed level spreader or another device that meets diffuse flow requirements per 15A NCAC 213 .0233. Diffuse flow requirements are described in Chapter 9 of the North Carolina Stormwater Design Manual, available at: https://deq.nc.gov/about/divisions/energy-mineral-]and- resourceslenergy-mineral-land-permit-guidancelstormwater-bmp-manual . This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Energy, Mining, and Land Resources, or permits required by the Division of Water Resources, Coastal Area Management Act, or any other federal or local governmental permit that may be required. D_EC�� North Carolina Department of Environmental Quality I Division of Energy. Mineral and Land Resources 512 North Salisbury Street 1 1612 Mall Service Center I Raleigh, North Carolina 27699.1612 919.707.9200 - . )o If you have any questions concerning this permit, please contact Bethany Georgoulias at telephone number (919) 707-3641. Sincerely, for William E. oby) Vinson, Jr., P.E., CPM, Interim Director Division of Energy, Mineral, and land Resources cc: Central Files Raleigh Regional Office Stormwater Permitting Program Files Wake County Environmental Services, Attn: Eric Green, P.O. Box 550, Raleigh, NC 27602 North Carolina Department of Environmental Quality I Division of Energy, Mineral and Land Resources 512 North Salisbury Street 1 1612 Mail Service Center I Raleigh, North Carolina 27699-1612 919,707.9200 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF ENERGY, MINERAL, AND LAND RESOURCES GENERAL PERMIT NO. NCG140000 CERTIFICATE OF COVERAGE No. NCG140463 STORMWATER AND WASTEWATER D[SCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Raleigh Concrete, LLC is hereby authorized to operate wastewater treatment system(s) and discharge stormwater only from a facility located at: Raleigh Concrete 1938 S. Wilmington Street Raleigh Wake County to receiving waters designated as Walnut Creek, class C;Sw waters, in the Neuse River Basin, in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts 1, II, 111, IV, V, and VI of General Permit No. NCG140000 as attached. This certificate of coverage shall become effective September 21, 2018. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this 215C day of September 2018. 0 for William E. (Toby) Vinson,`�r., P.E., CPM Interim Director, Division of Energy, Mineral, and Land Resources By the Authority of the Environmental Management Commission ACC-��0, 911 Paverstone Drive, Ste. E Raleigh,27615 PA BST DESIGN G RRO U P, 1 n A Office: � 919.848.4399 E IN (.; I \ h L, R I \ G & C: O NIS !I i. 1 1 \ (_; Fax: 919.848.4395 LETTER OF TRANSMITTAL To: NCDEQ DEMLR — Stormwater Program Department of Environmental Quality 1612 Mail Service Center Raleigh, NC 27699-1612 Re: 1938 S. Wilmington St, NCG14000 N.O.I. I am sending you the following item(s): Date: 06/26/18 Job No.: 339-16 COPIES DATE NO. DESCRIPTION 1 6/26/18 1 NCG140000 Application 1 6/26/18 2 $100 Application Fee Check 2 619117 3 Approved Plot Plan (wlin Approved Structural Construction Document Set) — 24" x 36", two (2) copies 1 1211311fi 4 Approved Stormwater Impact Analysis (associated with Approved Plot plan) 1 6/26/18 6 Narrative of Operations These are transmitted as checked below: ❑ As requested ❑ For approval ❑ For review and comment Remarks: Please let me know if you need any other information. Copy to: File ❑ For your use ❑ For Signatures R FC'�Fj V �'D ® For Submittal JUN ? 6 �0'8 DEAIR Sri D QUALiTy Signed: Samantha Brothers f Raleigh Concrete, LLC Ready -Mix Concrete Batch Plan NCG140000 N.O.I. Narrative of Plant Operation Waste Sources The following is a narrative description and identification of each type of process, operation, or production area that takes place at existing ready -mix concrete batch plant and how those activities might contribute fluid or solid waste. The plant is in Raleigh, North Carolina at address 1938 South Wilmington Street. The site consists of a mobile ready -mix batch plant, located towards the rear -center of the property. The mobile plant is CON-E-CO tO-PRO 327 series and operates as a dry -mix concrete plant. To the south of the plant, in the rear corner of the property, is a permanent truck wash station and pump house. Fluid and solid wastes are created on site during typical plant operations. Sources of waste water include vehicle and equipment cleaning, mixing drum cleaning, and stormwater runoff. Sources of solid waste include excess concrete from trucks returning to the site to be emptied_ Fluid Waste Management Mixer trucks enter the site from the driveway access on South Wilmington Street and pull up to the batch plant to receive automatically weighed materials and water. The trucks then drive to the permanent wash station to be rinsed before exiting the site. Alternatively, mixer trucks enter the site from the driveway access on South Wilmington Street and pull to the permanent truck wash station to be rinsed. In both cases, the washing of trucks is producing waste water. All runoff from this process is collected in the wash station. The wash station contains a series of three settling tanks. The water is then pumped from the third, and final settling tank, to be recycled for future concrete mixes on site_ The permanent truck wash station will not discharge any wastewater from the washing of the trucks. This plant is a relatively small operation, with limited truck washes daily. The only stormwater that is retained by the wash pit is that which falls in the immediate surrounding area. All other stormwater runoff onsite is directed around the wash pit. The wash pit is sized to retain necessary wastewater and stormwater that drains to it. Solid Waste Management Mixer trucks that arrive on site with any excess or improperly mixed concrete will be emptied and cleaned on site. All trucks will be emptied and cleaned within the truck wash station to ensure all wastewater is contained in the wash pit, All excess concrete will be set aside, typically in a mold, to cure and be used as recycled aggregate. To review, there is no discharge of wastewater from the site. Nor is there any disposal of solid or fluid wastes from the site. The only wastewater produced onsite is from the washing of mixer trucks. This wastewater enters the wash station and is processed through a series of settling tanks and later recycled for use on the plant. All stormwater leaving the site has no contact with the wastewater produced in the operation of the plant, Approved site plan includes a Stormwater Impact Analysis that further details the impacts the plant has on stormwater and the surrounding area. NOTICE OF INTENT RECEIVED 44 J UN 2 6 2018 FOR AGENCY USG ONLY Date Received 1)i-*'isi0n of F a ,01,AlJl1Mt Lp,jd 1,and Resources STcgj�i t�i Rf-ej'FP41tagw' Ccrtirtc ol'C,wcra c National Pollutant Discharge 1--iiiinination System Chrck ou l. �] ! er ut NCG 40Ass ned to 4006�) Y D �_3 National Pollutant Discharge Elimination System application for coverage under General Permit NCG140000: STORMWATER AND PROCESS WASTEWATER DISCHARGES associated with activities classified as: SIC (Standard Industrial Classification) Code: 3273 and like activities Ready Mixed Concrete This NOI may bean application to discharge process wastewater, NCG140000 contains effluent limitations for process wastewater discharges. Wastewater discharges must meet the requirements of these effluent limitations. An exceedance of any of these limitations will result in a violation of the permit conditions, For questions, contact the DEMLR Central Office or Regional Office in your area. (Seepage 8) 1) (Please print or type) Mailing address of owner/operator (official address to which all hermit correspondence will be mailed): Legal Company Name RAELIGHCONCRETELLC (Please attach the most recent Annual Report to the NC Secretary of State showing the current legal name. Alternatively this permit can be given to an individual.) Signee`s Name (as signed for in question 28 below) JOSE JUAN PLASCENCIA Street Address 1935 South Wilmington St City RALEIGH Telephone No, e,s esa o20, Alternate ContactName BRENDA ROOUE Alternate Contact Telephone (if different) 9193391 2) Location of facility producing discharge: Facility Name Street Address City County Facility Contact Telephone No. RALEIGH CONCRETE State NC ZIP Code 21601 Email BRENCA ROOUE®RALEIGHCONCRETELLC.COM Email (if different) 1939 5 WILMINGTON ST RALEIGH State NC ZIP Code 27603 WAKE BRENIDA RDOUE 919 33>3W-s3 Email BRENDA,R000ECcDRALEIGHC0h 3) Physical location information: Please provide narrative directions to the facility (use street names, state road numbers, and distance and direction from a roadway Intersection). EXIT 2986 off of 1-40 tReleigh tlelttma). Left 0 S launder SL, Left un Penmarc Ur, keep straight on waler works St Left on Favetteville St Left of South wilmintaton and destination if on the right. (A copy of a county map or tJSGS quad sheet with facility clearly located on the map is a required part of this application.) 4) Latitude 35754932 Longitude-786446-7 (deg., min, sec or decimal) 35a4S1 f$ fr _-76639`,C/ Page 1 of 8 SWU-NCG14-NOI Last revised 9/0 112017 NGG140000 N.O.I. 5) This NPDES Permit Application applies to the following (check all that apply): I ❑ New or Proposed Facility Date operation is to begin B Existing Facility Date operation began 09i0112017 Consultant's application information. - Consultant DAN PABST, PE Consulting Firm: PABST DESIGN GROUP, PA Mailing Address: 91 PAVERSTONE DRIVE STE. E City: RALEIGH State: NC Phone: ss( 9 ) Sas.4399 Email: DPABST(PPABSTDESIGN.COM Zip Code: 27615 (Optional) Staple Business Card I-Ierc: 7) Provide the 4 digit Standard Industrial Classification Code (SIC Code) that describes the primary industrial activity at this facility: SIC Code: 3 2 7 3 8) Provide a brief description of the types of industrial activities and products produced at this facility; (Attach a site diagram showing the process areas present at this facility.) READY -MIX CONCRETE Stormwater Discharge, Wastewater Treatment & Discharge and Permitting Information 9) Discharge points 1 Receiving waters: What is the name of the body or bodies of water (creek, stream, river, lake, etc.) that the facility stormwat r and/or wastewater discharges will end up in? +�M I CREEK _ 1il _ �Lj _� � — To find the waterbody, please see the NC Surface Waterbody Classifications map at https:l/deq. nc.gov/a bouVdiv i sionslwater-resources/water-resources-science-data Receiving water classification(s) for the waters: C.Nsw If the site will discharge to a separate storm sewer system, name the operator of the separate storm sewer system (e.g. City of Raleigh municipal storm sewer). CITY UPRALEiGN Page 2 of 8 SWU-NCG14-NOI Last revised 810112017 NCG140000 N.O.I. List discharge points (outfalls) that convey discharge from the site (both on -site and off -site) and location coordinates. Attach additional sheets if necessary, or note that this information is specified on the site plan. Be sure to indicate a type for each outfall listed below as Stormwater only, Wastewater only or Wastewater Commingled with Stormwater Outfall No. Stormwater only Q Wastewater only Wastewater Commingled with Stormwater Latitude (deg reeslminuteslseconds): 210133322.0341 N II + Longitude (deg reeslminuteslseconds): 7298825857 W Outfall No. Stormwater only Latitude (deg reeslminutes/seconds), Longitude (degreeslminuteslseconds): Outfall No. Stormwater only Latitude (degreeslminuteslseconds): Longitude (deg reeslminuteslseconds): Outfall No. Stormwater only Latitude (deg reeslminuteslseconds): Longitude (degrees/minutes/seconds): Outfall No. Stormwater only Latitude (degreeslminuteslseconds): Longitude (degreeslminuteslseconds): Outfall No. Stormwater only Latitude (degree slminuteslseconds): Longitude (deg reeslminutes/seconds): Outfall No. Stormwater only Latitude (degrees/minutes/seconds): Longitude (degreeslminuteslseconds): ❑ Wastewater only ll Wastewater only ❑ Wastewater only ❑ Wastewater only ❑ Wastewater only ❑ Wastewater only 1 W _ N W _ N W _ N W — N W _ N W Wastewater Commingled with Stormwater Wastewater Commingled with Stormwater Wastewater Commingled with Stormwater Wastewater Commingled with Stormwater Wastewater Commingled with Stormwater Wastewater Commingled with Stormwater Will this facility discharge wastewater to SA (Shellfish) waters? ❑ Yes MNo Note: Discharge of process wastewater to receiving waters classified as Critical Area (CA) must be reviewed by the N.C. Division of Water Resources, Public Water Supply Section ahead of approval. No new discharges of process wastewater are permitted in receiving waters classified as WS-1 or freshwater ORW. You must show all discharge points clearly on the submitted site plan. Be advised that NCDEQ may require you to apply for an individual permit, based on proposed discharge rates and receiving stream conditions (low flows, impairments, etc.) Page 3 of 8 SVW-NCGI4-NOI Last revised W0112017 NCG140000 N.O.I. 10) Each applicant shall provide the following information (attach additional sheets as necessary): • Two (2) site plans depicting the facility or site with numbered outfalls which indicate stormwater and wastewater outfalls. The plans shall legibly show. at a minimum, (existing or proposed): o Outline of drainage areas with topographical lines and features o Stormwaterlwastewater treatment structures o Location of numbered stormwaterlwastewater outfalls (corresponding to which drainage areas) o Runoff conveyance structures o Areas and acreage where materials are stored o Impervious area acreages o Location(s) of streams and/or wetlands the site is draining to, and any applicable buffers o Site property lines, North Arrow, and bar scale o If applicable, the 100-year floodplain line o Acreage of each stormwater and wastewater topographical area o Each of the facilities' wastewater or stormwater source and discharge structures and each of its hazardous waste treatment, storage, or disposal facilities o Site location (insert) Site plans shall be 24" x 3 6 " in size. • Line drawing and description: A line drawing of the water flow through the facility. A pictorial description of the nature and amount of any sources of water and any collection and treatment measures. • A narrative description and identification of each type of process, operation, or production area which contributes wastewater to the effluent for each outfall, and a description of the treatment the wastewater receives (or will receive), including the ultimate disposal of any solid or fluid wastes other than by discharge. Processes, operations, or production areas may be described in general terms (e.g, "ash silo"), 11) Does the applicant have any unresolved Notice of Violations (NOVs)? 19 No ❑ Yes Wastewater: 12) What types of wastewater does your facility generate or discharge? Type Hof Authorized Wastewater. Generate Discharge - Sent to WW Treatment , S� stem Vehicle and equipment cleaning VE 0 ❑ ❑ Wetting of raw material stockpiles RM ❑ ❑ ❑ Mixing drum cleaning MD L7 ❑ ❑ Further explanation, If necessary. WATER GENERATED BY VE.HICLESILQUIPMENT CLEANING IS CHEMICAL FREE AND IS THEN RECYCLED FOR USE OF THE MANUFACIURINGOF READY MIX CONCRETE 13) Will your facility spray -down or actively wet aggregate piles? 8 No ❑ Yes 14) Does the facility use any of the following on site? ❑ Phosphorus -containing Detergents ❑ Brighteners ❑ Other Cleaning Agents ❑ Non -Phosphorus -containing Detergents ❑ Other: Page 4 of 8 SWU-NCG14-NOI Last revised B10112017 NCG140000 N.O.I. 15) Are wastewater treatment facilities planned in the t 00-year flood plain? E1 No 0 Yes 16) Will your facility build a closed -loop recycle system (CLRSs) that meets design requirements in 15A NCAC 02T .1000 and hold your facilities' working volume'? ❑ Yes ❑� No If Yes, STOP COMPLETION of this permit. Contact DWR Non -Discharge Permitting Program for permitting requirements. 17) A wastewater treatment alternatives review is required by 15A NCAC 2H.0105 (c)(2) for any new or expanding water pollution control facility's discharge in Noith Carolina. You may attach additional sheets. a) What wastewaters were considered for this alternatives review? ❑ VE ❑ RM ❑ MD b) Connection to a Municipal or Regional Sewer Collection System: i) Are there existing sewer lines within a one -mile radius? ..................... ...... ❑ Yes O No (1) If Yes, will the wastewater treatment plant (VVV4rTP) accept the wastewater? .... ❑ Yes ❑ No (a) if No, please attach a letter documenting that the WWTP will not accept the wastewater. (b) If Yes, is it feasible to connect to the WVVTP? Why or why riot?' c) Surface or Subsurface Disposal System (e.g., spray irrigation): i) Is a surface or subsurface. disposal technologically feasible (possible)? ... ................. ❑ Yes ❑ No Wiry or Why not? ii) 1s a surface or subsurface disposal system feasible to implernerrY?'...........................0 Yes ❑ No Why or Wily not? iii) What is the feasibility of employing a subsurface or surface discharge as compared to a direct discharge to surface waters?' d) Direct Discharge to Surface Waters: Is discharge to surface waters the most environmentally sound alternative of all reasonably cost-effective options of the wastewaters being considered?'... ❑ Yes ❑ No i) If No. contact DEMLR's Land Application Unit to determine permitting requirements, e) If this review included all wastewater discharge types, would excluding some types (e.g. raw stockpile wetting) make any of the above non -discharge options feasible? ..............❑ Yes © No ' You may be asked to provide further information to support your answers to these questions after the initial review. Feasibility should take into account initial and recurring costs. Page 5 of 8 SWU-NCG44-NOI Last revised 8/01/2017 NCG140000 N.O.I. Stormwater: 18) Does this facility employ any best management practices for Stormwater control? EJ No ❑ Yes If yes, please briefly describe: 19) Does this facility have a Stormwater Pollution Prevention Plan? p No ❑ Yes If yes, when was it implemented? 20) Are vehicle maintenance activities (VMA) occurring or planned at this facility? p No ❑Yes If yes, does your VMA area discharge into your wastewater treatment device? ❑ No ❑ Yes Other/Permitting- 21) Does this facility have a Division of Land Resources Erosion & Sedimentation Control (E&SC) Permit? El No ❑ Yes If yes, list the permit numbers for all current E&SC permits for this facility: 22) Is your facility subject to Phase II Post -Construction Area? p No ❑ Yes If yes, who is the permitting authority? 23) Is your facility located in one of the 20 Coastal Counties? ❑ Yes ❑r No Is your facility adding more than 10,000 ftz of built -upon area or CAMA Major Permit? ❑ Yes E]No 24) Is your facility discharging wastewater (treated or untreated) such as water from wetting of aggregate piles, drum rinse -out, or vehicle and equipment cleaning to a stormwater BMP? I] No ❑ Yes If yes, please attach your approval from the permitting authority to do so. 25) Does this facility have any other NPDES permits? O No ❑ Yes If yes, list the permit numbers for all current NPDES permits for this facility: 26) Does this facility have any Non -Discharge permits (ex: recycle permits)? El No ❑ Yes If yes, list the permit numbers for all current Non -Discharge permits for this facility: _ 27) Hazardous Waste: a) Is this facility a Hazardous Waste Treatment, Storage, or Disposal Facility? 0 No ❑ Yes b) Is this facility a Small Quantity Generator (less than 1000 kg. of hazardous waste generated per month) of hazardous waste? El NoOYes c) Is this facility a Large Quantity Generator (1000 kg. or more of hazardous waste generated per month) of hazardous waste? Q No ❑ Yes d) Type(s) of waste: How is material stored: NIA Where is material stored: NIA Page 6 of 8 SWU-NCG14-NOI Last revised 8/01/2017 NCG140000 N.O.I. How many disposal shipments per year. Name of transport 1 disposal vendor: Vendor address: NIA Final Checklist This application will be returned as incomplete unless all of the following items have been included: d Check for $100 made payable to NCDEQ. d This completed application and all supporting documentation. See Question 10. ti ❑ If an Erosion & Sedimentation Control (E&SC) Plan is required from Division of Land Resources (DLR) or local designee: documentation verifying applicant has developed and submitted that Plan to the governing agency (required per 15A NCAC 02H .0138). ter 10 Two (2) site plans depicting the site plan with numbered outfails which indicate stormwater and wastewater I - outfalls. See Question 10. d A county map or USGS quad sheet with location of facility clearly marked. 28) Signatory Requirements (per 40 CFR 122.22) All applications, reports, or information submitted to the Director shall be signed and certified. a. All notices of intent to be covered under this General Permit shall be signed as follows: (1) For a corporation: by a responsible corporate officer. For the purpose of this permit, a responsible corporate officer means: (a) a president. secretary, treasurer or vice president of the corporation in charge of a principal business function, or any other person who performs similar policy or decision making.functions for the corporation, or (b) the manager of one or more manufacturing production or operating facilities employing more than 250 persons or having gross annual ;ales or expenditures exceeding 25 million (in second quarter 1980 dollars), if authority to sign documents has been assigned or deiegated to the manager in accordance with corporate procedures. (2) For a partnership or sole proprietorship: by a general partner or the proprietor, respectively; or (3) For a municipality, state, federal, or other public agency: by either a principal executive officer or ranking elected official. Certification: North Carolina General Statute 143-215.6 B(i) provides that: Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan, or other document filed or required to be maintained under this Article or a rule implementing this Article; or who knowingly makes a false statement of a material fact in a rulemaking proceeding or contested case under this Article; or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under this Article or rules of the jEnvirenmental Management] Commission implementing this Article shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed ten thousand dollars ($10,000). I hereby request coverage under the referenced General Permit. I understand that coverage under this permit will constitute the permit requirements for the discharge(s) and is enforceable in the same manner as an individual permit. l certify that I am familiar with the information contained in this application and that to the best of my knowledge and belief such information is true, complete, and accur i� 'dam Printed Name of Person Signing.('S CsfLp 1 A�� Title: _�_&-.)N Lnr (Si nature of Applicant) (Date Signed) Page 7 of 8 SWU-NCG14-NOI Last revised 8f01l2017 NCG140000 N.O.I. Notice of Intent must be accompanied by a check or money order for $100.00 made payable to' NCDEQ Mail the entire package to: DEMLR - Stormwater Program Dept. of Environmental Quality 1612 Mail Service Center Raleigh, North Carolina 27699-1612 Note The submission of this document does not guarantee the issuance of an NPDES permit. For questions, please contact the DEMLR Regional Office for your area. DEMLR Regional Office Contact information: Asheville Office .... Fayetteville Office . Mooresville Office . Raleigh Office ...... Washington Office Wilmington Office . Winston-Salem .-.- Central Office ....... (828) 296-4500 (910) 433-3300 (704) 663-1699 (919) 791-4200 ... (252) 946-6481 (910) 796-7215 (336) 771-5000 .. (919) 807-6300 Page 8 of 8 SWU-NCG14-Nql Last revised 8/01/2017 Raleigh Concrete, LLC Ready -Mix Concrete Batch Plan NCG140000 N.Q.I. Narrative of Plant Operation Waste Sources The following is a narrative description and identification of each type of process, operation, or production area that takes place at existing ready -mix concrete batch plant and how those activities might contribute fluid or solid waste. The plant is in Raleigh, North Carolina at address 1938 South Wilmington Street. The site consists of a mobile ready -mix batch plant, located towards the rear -center of the property. The mobile plant is CON-E-CO LO-PRO 327 series and operates as a dry -mix, concrete plant. To the south of the plant, in the rear corner of the property, is a permanent truck wash station and pump house. Fluid and solid wastes are created on site during typical plant operations. Sources of waste water include vehicle and equipment cleaning, mixing drum cleaning, and stormwater runoff. Sources of solid waste include excess concrete from trucks returning to the site to be emptied. Fluid Waste Management Mixer trucks enter the site from the driveway access on South Wilmington Street and pull up to the batch plant to receive automatically weighed materials and water. The trucks then drive to the permanent wash station to be rinsed before exiting the site Alternatively, mixer trucks enter the site from the driveway access on South Wilmington Street and pull to the permanent truck wash station to be rinsed. In both cases, the washing of trucks is producing waste water. All runoff frorn this process is.collected in the wash station. The wash station contains a series of three settling tanks. The water is then humped from the third, and final settling tank, to be recycled for future concrete mixes on site. l he permanent truck wash station will not discharge any wastewater frorn the washing of the trucks. This plant is a relatively small operation, with limited truck washes daily. The only stormwater that is retained by the wash pit is that which falls in the immediate surrounding area. All other stormwater runoff onsite is directed around the wash pit. The wash pit is sized to retain necessary wastewater and stormwater that drains to it, Solid Waste Management Mixer trucks that arrive on site with any excess or improperly mixed concrete will be emptied and cleaned on site. All trucks will be emptied and cleaned within the truck wash station to ensure all wastewater is contained in the wash pit. All excess concrete will be set aside, typically in a mold, to cure and be used as recycled aggregate. To review, there is no discharge of wastewater from the site. Nor is there any disposal of solid or fluid wastes from the site. The only wastewater produced onsite is from the washing of mixer trucks. This wastewater enters the wash station and is processed through a series of settling tanks and later recycled for use on the plant. All stormwater leaving the site has no contact with the wastewater produced iii the operation of the plant. Approved site plan includes a Stormwater Impact Analysis that further details the impacts the plant has on stormwater and the surrounding area. • Stormwater Impact Analysis For 1938 S. -Wilmington St City of Raleigh, North Carolina Submitted to: City of Raleigh Public Works Department Stormwater Utility 22 West Hargett Street Raleigh, North Carolina 27601 Prepared for: O Raleigh Concrete, LLC 512 Nowell Road Raleigh, North Carolina 27607 • ftc sT �FN NAB ?� Q oR�`�•��,�,oQU 1B RpER41i G Prepared by: PABST DESIGN GROUP, PA Date: December 13, 2016 PDG Project No: 238-13 91.1 Paverstone Drive, Suite E - Raleigh, NC 27615 — Phone 919.848.4399 Fax 919.848.4395 • Pabst Design Group, PA Stormwater Impact Analyses 911 Paverstone Drive, Ste. E 1938 S WOroington St Raleigh, NC 27615 Raleigh, North Carolina PDG: 339-16 Table of Contents I. Introduction ii II. Site Location and Description ii III. Proposed Improvements ii IV. Stormwater Requirements ii V. Calculation Methodology iv VI. Conclusion v VII. Pre/Post - Development Hydrographs Section 1 VIII. TR55 Tc and CN Calculations/Tables Section 2 IX. NOAA Precipitation Frequency & intensity Charts) Section 3 X. Erosion Control Calculations Section 4 Xi. Erosion Control Drainage Area Map Section 5 XII. Wake County Soil Survey Map Section 6 XIII. USGS Map Section 7 XIV. Drainage Area Maps Section 8 XV. Nitrogen Loading Calculations Section 9 XVI. Nitrogen Loading Maps Section 10 XVII. Recorded Plats Section 11 I Raleigh Concrete, LLC 512 Nowell Raod Raleigh, NC 27607 Pabst Design Group, PA 911 Paverstone Drive, Ste. E Raleigh, NC 27615 I. Introduction Stormwater Impact Analyses 1938 5 Wilmington St Raleigh, North Carolina POG: 339-16 • Pabst Design Group, PA of Raleigh, NC has been contracted by Raleigh Reclamation, LLC (the Client) to provide this analysis, along with supporting calculations, to the City of Raleigh (the COR) for their review. Information contained herewith will assist the COR with their evaluation of site development for the subject property as it relates to specific COR and State regulations. IL Site Background The project site is located in Raleigh, North Carolina on the west side of South Wilmington Street and consists of one parcel, Wake County Pin 1702-69-1938 (previous two -parcels, 1702-69-1912 and 1703-60-1181). The property, totaling three and eighty-one hundredths (3.81) acres, is within the Walnut Creek watershed in the Upper Neuse River basin. The site is currently zoned Heavy Industrial (IH) and is operating under the use category of Waste Related Service with impervious coverage of one hundred twelve thousand five hundred twelve (112,512) square feet. While, there is no record of permit for the limits of gravel on site, the City of Raleigh has accepted the existing gravel/impervious area under the previously permitted vehicles sales lot impervious area (Transaction Number T-104660). Therefore, for the purpose of this report, the pre -development conditions will reflect the most recently permitted site conditions of the commercial vehicles sales lot. For further differentiation of current site conditions and pre -development site conditions, please refer to the copy of the recorded plat of the waste related service (13M 2016-1695) and recorded plat of the vehicle sales lot (BM 1006-1529), included in this report, III. Pre -Development Site Conditions The pre -development site conditions consist of a paved asphalt parking lot, commercial building, accessory buildings, landscaped areas and utility services. As indicated by historic topography, the pre -development site generally drains in the south east direction to existing ditch running parallel to the front of the property within the Wilmington Street right-of-way. Existing impervious coverage is one hundred thirty-nine thousand ninety-two (139,092) square feet with a percent impervious surface of eighty-three and forty-six hundredths (83.46). Please refer to the Pre -Development Nitrogen Loading Map and the Pre -Development Drainage Area Map included in this report for information on pre -development site conditions. IV. Post -Development Site Conditions The purpose of this project is to construct a four thousand seven hundred fifty-eight (4,758) square -foot permanent truck wash out area, three water reclamation tanks, and a pump house. Infrastructure improvements will include, but are not limited to, the construction of a private water service to the truck wash area and the approximate location of the mobile concrete batch plant, which will be assembled on site in the future. The project will disturb approximately forty-five hundredths (C1.45) acres. As indicated by topographic survey, the subject site will generally drain in the south east direction to existing catch basins running II Raleigh Concrete, LLC 512 Nowell Raod Raleigh, NC 27607 Pabst Design Group, PA Stormwater Impact Analyses 911 Paverstone Drive, Ste. E 1938 S Wilmington St Raleigh, NC 27615 Raleigh, North Carolina PDG: 339-16 parallel to the front of the property within the Wilmington Street right-of-way. Post - development impervious coverage will be one hundred twelve thousand five hundred twelve (112,512) square feet with a percent impervious surface of sixty seven and seventy-nine hundredths (67.79). Please refer to the Post -Development Drainage Area Map included in this report and the submitted Plot Plan set for more information on the post -development site conditions. V. Stormwater Requirements Water Quality The proposed development is located the Upper Neuse River Basin and is subject to the City of Raleigh's stormwater regulation. However, the post -development impervious surface, 2.58 acres, is less than the pre -development impervious surface, 3.20 acres. As such, no water quality treatment will be required. Please refer to the Pre- and Post- Nitrogen Loading Maps for tabulation of impervious areas. Water Quantity Per the City of Raleigh's water quantity requirements, Stormwater attenuation is required onsite in order for the 2-, 10-, and 25-year, 24-hour storm event peak flows to equal to or less than pre -development conditions (or within 10% of pre -development levels). However, ® after providing analyses, it has been determined that the flow rate for the post -development condition is less than the pre -developed flow rate for the site. Please refer to the Hydroflow analysis provided within this report. VI. Calculation Methodology Runoff Rates for pre -development and post -development were calculated using the SCS method. Each drainage area has a time of concentration and runoff curve number calculated for it. Hydraflow Hydrographs 2007 was utilized for this analysis to overlay hydrographs for cumulative peak flow analysis, as well as routing flows through the underground detention system. The time of concentrations have been calculated using the SCS Segmental Approach (TR-55). Drainage areas that were less than 5 minutes time of concentration were given an assumed value of 5 minutes, according to SCS methodology. The segments corresponding to the calculations for times of concentrations for pre -development and post -development drainage area maps are included with this report. Curve number values have been based upon Table 2.2a of the TR-55 Manual. Average velocities for estimating travel time have been based upon Table 2.1 of the TR-55 Manual. Values for roughness coefficients were taken from Table 3.1 of the TR-55 Manual. Runoff Coefficient values for drainage areas have been based upon Table 2.2 of the City of Raleigh Stormwater Design Manual. lil Raleigh Concrete, LLC 512 Nowell Raod Raleigh, NC 27607 Pabst Design Group, PA 9.11 Paverstone Drive, Ste. E Raleigh, NC 27615 Stormwater Impact Analyses 1938 5 Wilmington St Raleigh, North Carolina PDG: 339-16 Existing soil conditions have been classified as Ma — Made land for the majority of the site. The soil group was conservatively assumed to be Group D based upon the description of soil type provided in the Wake County Soil Survey. Topographic, location, and boundary survey information was provided by PTS Land Surveying for the current condition of the site. The City of Raleigh provided historic topography from 2004 for pre -development analysis. VII. Conclusion PDG's analysis consisted of evaluating pre- and post- development conditions of the subject site. There was a reduction of total nitrogen loads from pre -development conditions to post - development conditions due to the reduction of impervious surfaces. Additionally, this reduction of impervious surfaces causes the post -development peak flow rates for all three design storms to be reduced from pre -development conditions. The pre- vs post - development peals flow comparison summary is provided in Table 1. Based upon the analysis provided within this report, it was determined that neither a treatment device, nor a detention system is required for this project. Table 1 Peak Flow Comparison Chart Q(2) Q(10) Q(25) Condition (CFS) (CFS) (CFS) Pre -Development Peak Flows 26.58 39.99 47.$4 Post -Development Peak Flows 17.58 27.47 33.21 % Change -33.86% -31.31% -30.58% Table 2 Impervious Area Comparison Chart Building Asphalt Gravel Concrete Total Site Condition Area Pavement Pavement Pavement Impervious (ACRES) (ACRES) (ACRES) (ACRES) (ACRES) Pre -Development 0.64 2.03 0.52 C! 3.19 Post -Development 0.01 0.24 2.19 0.14 2.58 0 Iv Raleigh Concrete, LLC • 512 Nowell Raod Raleigh, NC 27607 Pabst Design Group, PA 912 Paverstone Drive, Ste. E Raleigh, NC 27615 • • 11 VIII. Pre / Post - Development Hydrograph Stormwater Impact Analyses 1938 S Wilmington St Raleigh, North Carolina PDG: 339-16 Raleigh Concrete, LLC 512 Nowell Raod Raleigh, NC 27607 1 Hydrograph Return Period Rep y ra ow Hydrographs Extension for AutoCADV Civil 3130 2014 by Autodesk, Inc. v10.3 Hyd. Hydrograph Inflow Peak Outflow (cfs) Hydrograph type hyd(s) Description (origin) 1-yr 2-yr 3-yr 5-yr 1 10-yr 25-yr 50-yr 1 100-yr I 1 I SCS Runoff -- 2 SCS Runoff 21.47 26.58 -- --- 39.99 47.84 -- til}.28 Pre-Dev drainage Area 13.97 17.68 ----- --- 27.47 33.21 42.29 Post-Dev Drainage Area 'THIS DATA INDICATES THERE IS A REDUCTION IN THE PEAK FLOW FOR EACH DESIGN STORM DUE TO THE REDUCTION OF IMPERVIOUS SURFACES. Proj, file: SIA_12-13-16—SAB.gpw Wednesday, 121 14 / 2016 Hydrograph Summary Report Hydraflow Hydrographs Extension for AutoCAD® Civil 3DO 2014 by Autodesk, Inc. 00.3 Hyd. No. Hydrograph type, (origin) Peak flow (cfs) Time interval (min) Time to Peak (min) Hyd. volume (tuft) Inflow hyd(s) Maximum elevation (ft) Total strge used (cuft) Hydrograph description 1 SCS Runoff 26.58 2 716 57,810 — ------ - Pre-Dev Drainage Area 2 SCS Runoff 17.68 2 716 37,169 — — — — Post-Dev Drainage Area SEA 12-13-16_SAB.gpw Return Period: 2 Year Wednesday, 12 / 1412016 Pabst Design Group, PA 911 Paverstone Drive. Ste. E Raleigh, NC 27615 0 E IX. TR55 Tc & CN Calculations Vi Stormwater Impact Analyses 1938 S Wilmington St Raleigh, North Carolina PDG:339-16 Raleigh Concrete, UC 512 Nowell Raod Raleigh, NC 27607 0 �1 I Time of Concentration Calculatior SCS Segmental Method Project: 1938 S. Wilmington St. Purpose: Determine tc for PRE -development DA-1 Prepared by SAB Date: 13-Dec-16 Checked by: PDP Date: 13-Dec-16 Sheet Flow Segment ID AB 1. Surface description (TR-55, Table 3-1) asphalt, Smoot 2. Manning's roughness coeff., n (TR-55, Table 3-1) 0.011 3. Flow length, L (Total < 100 ft) " ft 214 4. Two-year 24-hour rainfall, P (NOAA data) T, = 0.007 (nL )" in 3.49 5. Land slope, S p os S° 4 ft/ 0.045 z fi. Travel time, t h1 0.03 Sheet Flow Segment ID BC 1, Surface description (TR-55, Table 3-1) asphalt, smoot 2. Manning's roughness coeff., in (TR-55, Table 3-1) 0.011 3. Flow length, L (Total < 100 ft) ' ft 44 4, Two-year 24-hour rainfall, P (NOAA data) T, = 0.0 0 7 (n L) P 8 in 3.49 5. Land slope, S p 0.3 S 0 4 ft/ 0.068 6. Travei time, t hr 0.01 Sheet Flow Segment ID CD 1. Surface description (TR-55, Table 3-1) asphalt, smoot 2. Manning's roughness coeff., n (TR-55, Table 3-1) 0.011 3. Flow length, L (Total < 100 ft) ' ft 29 4. Two-year 24-hour rainfall, P (NOAA data) T, = 0,007 (n 1. }° B in 3.49 5. Land slope, S p ° 5 5° 4 ft/ 0.100 6. Travel time, t hr 0.00 Sheet Flow Segment ID DE 1. Surface description (TR-55, Table 3-1) asphalt. Smoot 2. Manning's roughness coeff., n (TR-55, Table 3-1) 0.011 3. Flow length, L (Total < 100 ft) ' 0 92 4. Two-year 24-hour rainfall, P (NOAA data) T, = 0,00 7 (itL }"'a in 3.49 5. Land slope, S pz 0 .s 5 0.4 fUJ 0.020 6. Travel time, t hr 0.02 Sheet Flow Segment ID EF 1. Surface description (TR-55. Table 3-1) asphalt, smoot 2. Manning's roughness coeff., n (TR-55, Table 3-1) 0.011 3. Flow length, L (Total < 100 ft) ' ft 151 4. Two-year 24-hour rainfall, P (NOAA data) T = 0.00 7 (nL }" R in 3.49 5. Land slope, S P20.5 S 0.4 ft/ 0.020 fi. Travel time, 1 hr 0.03 TIME OF CONCENTRATION, Tc hi 0.08 min 4.8 Runoff Curve Number (CN) Calculation Project: Condition: Purpose: Prepared by Checked by: Total Site Area: Total Drainage Area Drainage Area SCS Segmental Method 1938 S. Wilmington St. Pre -development Determine CN Values for Drainage Areas SAB Date. 13-Dec-16 PDP Date: 13-Dec-16 3.81 Acres 6.16 Acres DA-1 Soil Group Cover Type CN Value Area (ac) CN*A (ac) Open, poor Sub Area 1 D 89 2.01 178.89 condition Impervious,paved Sub Area 2 D 98 3.63 355.74 Impervious,91 Sub Area 3 D 0.52 47.32 gravel * Open Space, Fair - was recently graded and seeded during constrction of Bartram Place Composite CN W Total (CN*A)1 Total A Totals 5.64 Composite CN 1 94.8 (for prev-development flow from DA-1) 534.63 11 EJ Time of Concentration Calculation ® SCS Segmental Method Project: 1938 S. Wilmington St. Purpose: Determine tc for POST -development DA-1 Prepared by SAB Date: 13-Dec-16 Checked by: PDP Date: 13-Dec-16 Sheet Flow Segment ID 1. Surface description (TR-55, Table 3-1) 2. Manning's roughness coeff., n (TR-55, Table 3-1) 3. Flow length, L (Total < 100 ft) ` ft 4, Two-year 24-hour rainfall, P (NOAA data) T = 0.0 07 (n L )° B in 5. Land slope, S P °.55 °.4 ftlft a 6. Travel time, T t hr Sheet Flow Segment ID 1. Surface description (TR-55, Table 3-1) 2. Manning's roughness coeff., n (TR-55, Table 3-1) 3. Flow length, L (Total < 100 ft) ` ft 4. Two-year 24-hour rainfall, P (NOAA data) T, = 0.0 07 (nL )° S in 5. Land slope, S P ° S S 0.4 ft/ft Z 6. Travel time, T t hr Sheet Flow Segment ID 1. Surface description (TR-55, Table 3-1) 2, Manning's roughness coeff., n (TR-55, Table 3-1) 3. Flow length, L (Total < 100 ft) ` ft 4. Two-year 24-hour rainfall, P (NOAA data) T = 0.0 0 7 (n L )0" in 5. Land slope, S P ° s S 0A Tuft z 6. Travel time, T t hr TIME OF CONCENTRATION, Tc for DA-1, Pre -development 0 AB grass, short 0.150 83 3.49 0.120 0.07 BC gravel, smooth 0.011 78 3.49 0,120 0,01 CD concrete, smooth 0.011 42 3,49 0.050 0,01 hri 0.072 min 4.3 Runoff Curve Number (CN) Calculation SCS Segmental Method � Project: 1938 S. Wilmington St. Condition: Pre -development Purpose: Determine CN Values for Drainage Areas Prepared by SAB Date: 13-Dec-16 Checked by: PDP Date: 13-Dec-16 Total Site Area: 3.81 Acres Total Drainage Area: 4.43 Acres Drainage Area: DA-1 Soil Group Cover Type CN Value Area (ac) CN*A (ac) Open' poor Sub Area 1 D condition 89 1.96 174.44 Impervious,98 Sub Area 2 D 0.38 37.24 paved Impervious, Sub Area 3 D gravel 91 2.09 190.19 * Open Space, Pair - was recently graded and seeded during constrction of Bartram Place Composite CN = Total (CN*A) / Total A Totals 2.34 211.68 Composite CN 90.5 (for prev-development flow from DA-1) L 0 El Chapter 2 Estimating Runoff -, Technical Release 55 Urban Hydrology for Small Watersheds Table 2-2a Runoff curve numbers for urban areas 11 Curve numbers for Cover description hydrologic soil group Average percent Cover type and hydrologic condition impervious area y A B C D Fully developed urban areas (vegetation established) Open space (lawns, parks, golf courses, cemeteries, etc.) T: Poor condition (grass cover ¢ 50%).......................................... 68 79 86 Op Fair condition (grass cover 50% to 75%).................................. 49 69 79 84 Good condition (grass cover > 75%)......................................... 39 61 74 8o Impervious areas: Paved parking lots, roofs, driveways, etc. (excluding right-of-way) ............................................................. 98 98 98 98 Streets and roads: Paved; curbs and storm sewers (excluding right-of-way)................................................................................ 98 98 98 98 Paved; open ditches (including right-of-way) .......................... 83 89 92 93 Gravel (including right-of-way) ................................................. 76 85 89 91 Dirt (including right -of -way) ...................................................... 72 82 87 89 Westem desert, urban areas: Natural desert landscaping (pervious areas only) 9/..................... 63 77 85 88 Artificial desert landscaping (impervious weed barrier, desert shrub with I- to 2-inch sand or gravel mulch and basin borders)...................................................................... 96 96 96 96 Urban districts: Commercial and business................................................................. 85 89. 92 94 95 lnd►.strial........................................................... .:...................... .......... 72 8L 88 91 93 Residential districts by average lot size: 1/8 acre or less (town houses) ................. .:...... .......................... —.... 65 77 85 90 92 1/4 acre................................................................................................. 38 61 75 83 87 1/3 acre.................................................................:.............................. 30 57 72 81 86 1/2 acre................................................................................................ 25 54 70 80 85 1 acre................................................................................................... 20 51 68 79 84 2 acres.................................................................................................. 12 46 65 77 82 . Developing Urban areas Newly graded areas (pervious areas only, no vegetation) Y............................................................... 77 86 91 94 Idle lands (CN's are determined ufrng cover types similar to those in table 2-2c). Average runoff condition, and Io = 0.2S. z '[lie average percent impervious area shown was used to develop the composite CN's. Other assumptions are as follows: irnpervio«s areas are directly connected to the drainage system, impervious areas have a GN of 98, and pervious areas are considered equivalent to open spare in good hydrologic condition. CN's for other cumbinat.ions of conditions may be computed using figure 2-3 or 2-4: CN's shown are equivalent to those of pasture. Composite CN's may be computed for other combinations of open space cover type, 4 Composite CN's for natural desert landscaping should be computed using figures 23 or 24 based on the impervious area percentage (CN = 98) and the pervious area CN. The pervious area CN's are assumed equivalent to desert shrub in poor hydrologic condition. 5 Composite CN's to use for the design of temporary measures during grading and construction should be. computed using figure 2-3 or 2-1 ebased on the degree of development (impervious area percentage) and the CN's for the newly graded pervious areas, (210-VI-TR-55, Second FA, dune 1986) 2-5 Chapter 3 Time of Concentration and Travel Time Technical Release 55 Urban Hydrology for Small Watersheds Figure 3-1 Average velocities for estimating travel time for shallow concentrated flow '.id .20 .10 .02 .01 005 1 .� I ,....F....... ....».w., i i .......... 4 --' r $ : � � I � � �+• 7 l 1 � tti ' �.,,.....5-....,a..._ j � .artx3tiww+.wsuwrMY+w�..i'r. +#I .�..k.�-=.�; � axvwnarw.r.s'aww' � �.�»a•.+:y.��.+E,>;i '.�`-" j j•^ "ti"r`.Yk'^'i"'-y..s—.{—f�, I 7 ; rw�.;..�•'� ��n� $. � 1 I J ax .•.� �...Lr ,^��} J..1�: xaw:j. F y�3- I:,a�'�,.dl!,. i { uww.::,.d�...._�•.�.....}......,y..» •...+?,.w.:_i#.. _...i/. � 4 � � F I • -.�« � , �� p' 1 � ... � ........ i.... . 1 Y+er-W��. }nrs.�e.v a ej e - t .--�.. t ,I � nxax..wear�.nca.«wa-+w.'v-wrwArkw,E .i rk �:., I +.w..i. K rr.x✓.Fk W a --.-._t...........i..�....,.+� �.... E T I � j 1 I I .emu �.w • ww,.�xxx.: aw• ' 3 I ii9 197j7j7i f � lTi �� - f 1 a - y�{{{���,.�»�w.•L.. � F 1 1 1 I i 1 ' I 1 E i 111 I { kit ed,..y 2 4 6 10 20 Average velocity (fttsec) E • 3-2 (210-VI-TR-66, Second Fad., ,Tune IW) E 2 CJ Chapter 3 Sheet flow Time of Concentration and Travel Time Technical Release 55 Urban Hydrology for Small Watersheds Sheet -flow is flow over plane surfaces. It usually occurs in the headwater of streams. With sheet flow, the friction value (Manning's n) is an effective rough- ness coefficient that includes the effect of raindrop impact; drag over the plane surface; obstacles such as litter, crop ridges, and rocks; and erosion and trans- portation of sediment. These n values are for very shallow flow depths of about 0.1 foot or so. Table 3-1 gives Manning's n values for sheet flow for various surface conditions. Tattle 3-1 Roughness coefficients (Manning's n) for sheet now Surface description 11,V Smooth surfaces (concrete, asphalt, gravel, or bare soil) .......................................... CED Fallow (no residue) .................................................. 0.05 Cultivated soils: Residue cover <20%......................................... 0.06 Residue cover >20%......................................... 0.17 Grass: Short grass prairie ............................................ 0.15 Dense grasses y................................................ 0.24 Bermudagrass.................................................. 0.41 Range (natural)......................................................... 0.13 Woods& Ughtunderbrush .............................................. 0.40 Dense underbrush ............................................ 0.80 . The n values are a composite of inforn►ation compiled by f ngwAn (1s86). Includes species such as weeping lovegrass, bluegrass, buffalo grass, blue gram grans, and native grs-ss mixtures. When selecting n, consider cover to a height of about 0.1 ft This is the only prut of the plant cover that will obstruct sheet flow- For sheet flow of less than 300 feet, use Manning's kinematic solution (Overtop and Meadows 1976) to compute TC. Ttr _ 0.007{nL}0.8 1Pjs OA where: T, = travel time (lu•), n = Manning's roughness coefficient (table 3-1) L = flow length (ft) Pz = 2-year; 24-hour rainfall (in) s = slope of hydraulic grade line (land slope, ft/ft) This simplified form of the Maluung's kinematic solu- tion is based on the following: (1) shallow steady uniform flow, (2) constant intensity of rainfall excess (that part of a rain available for runoff), (3) rainfall duration of 24 hours, and (4) minor effect of infiltra- tion on travel time. Rainfall depth can be obtained from appendix B. Shallow concentrated flow After a maximum of 300 feet, sheet flow usually be- comes shallow concentrated flow. The average veloc- ity for this flow can be determined from figure 3-1, in which average velocity is a function of watercourse slope and type of channel. For slopes less than 0.005 ft/ft, use equations given in appendix F for figure 3-1. Tillage can affect the direction of shallow concen- trated flow. Flow may not always be directly down the watershed slope if tillage runs across the slope. After detennining average velocity in figure 3-1, use equation 3-1 to estimate travel time for the shallow concentrated flow segment. Open channels Open channels are assumed to begin where surveyed cross section information has been obtained, where channels are visible on aerial photographs, or where blue lines (indicating streams) appear on United States Geological Survey (USGS) quadrangle sheets. Manning's equation or water surface profile informa- tion can be used to estimate average flow velocity. Average flow velocity is usually determined for bank - full elevation. (214-VI-TR-55, Second Ed., June 1086) 3-3 10 SOLI, MRI r,Y U— 5 to 72 hwh(s 'f-, mmUed gmn FellnlviWWwmvu, nrid red clay; niur+live; firm] whon moist; atrnnMy noid. Tile A itnrMmw angr. from B to 20 inches In combineffthicic- =6 And Amn dude brLmn or (lurk gruyish brown to Light; yellon'islt 6nn.v-t rr light, grn!l ill color. The Bt htlrivus rnugo frnn: 21 to l�A} N(Ifi t in i:on:hintd Uilc:ktlesa. 'I'hOr texture ir3 mostly Faudy lotto, or ,nudy clay Lonny that is .IS W 35 percent clay. In laia(Nml tdleut hoflzouv (.()ttal1l jV.,Vk(1414 a11(l lenses of sand. The color of the Bt horiz,)Lly roligl^s frr,n: yollmviph !)mwn to I1(rle yellow or llOU arclttiAsh gray in JOYR. or n1we .VeIIOVvi:+11 hIle4, 11L rinees feic• to t`tllalnlOrl gray moltley Lira within 10 inelie�i of the tor) of the ullnerniost Bt horizon. 711w 133g lunizou i.; rilln hromi W light; ltrownl h gray nr hrowni4h yclloNv .lull gcqnorally clUnN% (iiKowt, grrlgi';h mdlhm `The ,•olllbined ihi(•Ic*:,•:(.s of tha A horl7.ms nna B hrlrtznn:= is moon titan 10 L-lOW% T)ellth to hMrnch 13 more than 20 feet. T,y n(lh1 ntrg ;+nl':w oe:(,tir with ClolclAoro no }thins sours, and their texture is ,graULlr ro t;h,� texture of those soils. They cn'o I(>.ss xell drainer! Ulm! the Goldm!loro mill+, however, anti are I etter dvd!wd than die. ltnins, fgnchburtr sandy loam (0 to porcent, � ;wes) This is tho only T:ynehhur� Soil inallpe(} in 1`'lLlce Courl- ly. Tt, is in (lepllr)ti iut) in 1lI)1:1lllls of lllc (..'.o11=ta.l l'itlin. Tho surface layer Is d:LI•k-brown or light -gray to very ,lark my sandy ]Dail s to `?0 Ad", t1AL 'I'lle Moil iy 3U to 60 inc}tes {hi,:lz lima]. is Dale -yellow to yellwmi11- brown, friztblo sandy l( kin to sandy cl-a.y loll:ll mottle([ MA AM of gnq. I LlfiltL'atiotl K gWd, ,lull sut'face runof is I'dOm'. 'i'lli soil is cllsy to keep in moil .tiltli mid can be ,rorltecl 01rourltonf, lI :_rifle rrt.rlrr, of moi:z(ltro +!ollferll,. i?rniIMgC is acquired for ]loin; ro1v crops to do well on thk SOL It pAipvt' dr;tilrnre, k prt7l,icl�1_i, (.his Sii1 is well sidled to most of the locwlk rro:vn crops. It. is ns�ii mnildy for rrnv ("r',)1is OI• T12L9tLlre. (('>1:lnllilil,� nilit. I.l.w-1, Nvoo(11nnd Stability group 4, 1l•lldlire salt:lbillty groiip Made land (lvtc, i a Inisc.c}lzllcou ll ild type in lrllit:h 61C are'ls hail' kxf ll nlloxr d by illan to the oxt.ellt tllt+t tht" proRiv of the Wginn] soil, r.sluxlt Ile rrf•urniZiId. The altered soil tll:Lseri:li duos Ilot function as dial the origilial I011, •`alit in n fill]' places it, dney nal, ivsertd& the or' ival will. Scene areas of Millie ]rill=:1 ;i'c w :tlrt(lp tt'l(fn cllltina aml fillillr lyrlti tfc)ne io von;;ti'(ha 1r,tr!vng 1Ots, air•fiel&, iiltf+:s trial !t(S. and higrl)ir:lj• Illlolvhangv?F. Ill 111ally places all fit' P,1& of the Mail "]lid part of tile. 131:1tevi:11 ltnilwl1'ttTg {lle. original 4clils w.,H cud, ftolll Oni, AMR and 11'rh nlrlte.;_l to nlll,fhier :l;o_ -for use }14' till lrinlerinl , (.)tllr'r nr(::L; of Afaile 1.IIu1 Ilse a('al' (plumes '•1•llrl'(' the overl7ili'tir'SI ham huull dulliped into lard( llunllld". '11) t.11w, plarc.s gravel has No spread and l;acked ilito die soil:, witil Ella: _c,il nrlterial In, ("ollllsaried :tnd hard. Pie aruas included in this land type. are, so diver',u Ili cl!:tI'aCtr.ristii's t•l:itt: r'0113ml Whawnts cannot be 1ledu about, their]. Oilslle exundnrttt ui of imidL :).1'B:l I" 110re.8`ary lle.l'(ire any land nsc is 111mined. (Not pla(_ed in a elltnt.- Ililitu limit.] lspnrllrtncl stliLabilit;�' ilia]]) 1.3, rl'iltllife NO alililty WMILn 5� Madison selies 'l.'llo A[Lll.isurl OWN of g:t'ltly' �lopitig to Iuod'- t-,niII,,I-" yte:!p, r[eep, well-dra111ed AN that occlipy fairly Anil]{] areas on Piadmout uplands in Hie nordierll pnrL of the county. These soils are oil side slopms a.ilif ( rolln(kd Wks tirll( re IN Met' nm- I Avadoil A, nbo 60 feet l3(.:twemi tho ldghesL and Te 1 must. ]points. They liliva for•nied under forest in 11ia.terial tlult i ealkherml froltl Iuif-a scllist, Inie"t. gn(;is!�, :t:lii otlww ar.i(lic: ruolts. Nlitural feriilii.y fine] the content of urp nic fnaUer are. 1[l5i ()erineability is Illoder'tlte, 1111d lira ati-rlilablF Neater capticlty is nvAiiiiil. The sllrili!i:-swell potential is lnod- or:lte. Kxvg0. in nr"Y tier.!; lt:", reci: vwl lbmq thvsn soil,i are strongly tici!l. 16-,pon e is roots if 1Itilabll opplica- Airs of lime and feri.ilize.r are ni ldo The Aladition -s0315 of ltWa1w. Comity are not. iniportUut for farming, Thoy area mostly in furt.;t°. lMprnsentativo profile Of a AIndison sanely Mani in -It moods] aretl Z':;1 ]slicks trt'�r of Mlle c.uo-,c. Itirof l;1-:[I;f: oil V.C. IIi ;hway No. 98 and 10 }"aids sottrh of road A11—() to (', inches, brawn (10)"n ;i:il Rintly Irninl ; wp:11;, memarn, gmnon r sr.rnie.tnro: very frinhlo w1wri itsni=t.; mnn3• ffnrw, nmody and fiiri•n11s rootQ: common flrtc mien ]lakes; few small gilartz and (lu.lrtz min sc•hi5t lwh- wes; L emuni at_,io: nhrnpr, wavy honn(I:my. 131.-6 to 12 iixhes, red (2.:-)YIt 4!(i) heavy sandy clrt,v Ion."; wezlk• rizwtlftttll, st1Iy;tn9ular l;lockr' nructurT: friaWo wham luoiq, r(lightly ativky rin(l slightly Mastic Nvltcrt n•cl; (: n.nlorl, Cirle, i1•oody Awl fibrous roots; coirrmort tine mire Ilnkes: stain 4— acid; ubruvt, wavy MIX ry- 112r— 2 to 'all inrltrs, r(-ll i _' )YR 4i131 elay toanr ; 'afiderate. rock("" ximma witr wocky Strtlr,tnrc; frialIc. when ntniAt, 411ghtly (-tkllty n11ll slil;llll,v l,lttsl:io a•lr(•Lt wcl ; VOL c1:1y 640: CMnnlon. till,'• n'(1pd3 111u1 fibrous root; ninny fine tllicrl ft:1kr few l,nrti.- cli?Inti- gratc.-tl ichist fr:l„nlcnt:; S-trwigly acid; nbl•llfit., w,t hounda ry. in(Jivs, mil (_/.tSYIi •t (f,) snrt:ly r.I;ri llla.nl : rno,t :11e, rrte(4in1 enh,Inrnhn- hloeky 9rrnc.11re: Crtnllk: -1mik moist slightly sticky :uLrl sligbUy plasti.: Mien r,vl: fa'u' GW (•IrIC tuns: finv. `Mali, 1foc>fly .r•ools' 111;rrtr 1111e Illi(:rl IIat;c c+!ertni(ut .cIA11�4 frns1l1(!1AS, ruld ir11t, yollnry .ind dusky-rol vwrtics armulit Chu fui - Irle'r!1>; sri'n11y1!' ack.: I,—:;,? to -1 i 01"hes -I-, !K1101ctl tltlsl:y-reLi, s'i t=• intle-p.,110 v. strum hr'lun. 11nd brown gilt ta-utn di.�intrt�rntl•rl rtu:lriz I:,i a ra'1r>:T: r(1111n1(in (1211c 11111w., timt. :11,11('r111 to Ili di'dIll (,2L-:lt?fl ;,:1L'IIFt ; fry, San;tI!, u'nody 1'n(,I:+ esr(,tt(linA tip n (ir"llth (If MOLT 01:1n •iS imrl:e r•t.r(nLcly at;i(l. T11(t -&p luu' x ul r^t:L;:,:; fr( (tl :, t:(> Sfi i%(•ftes in thirklut,.a an(I frout ([ark hruwn ro hrfovu ill f'olor. Tlw 1.{ rrl.ir f• fr01'[L 111 51 as i OW6 111 ('nn1141Irlt S'rtlltty toy login t" emy ILL i"Wrlt, '1'lI(: 1t1 lluriioll i£! p",Ilotviail red to rtrd. Th,: ":faint cola] of (lick C! 1=t,t•izt.nr; is hatn b"t. the Mor fit Mae horiz(,ns ranys to darl: real. rTY nutllUer of moat Antos rnngos faun] A"v In rutnmwi in A" A hurizmi rend fru]u (,(."],Mall to rn;tor ill tllr; III hnl1z-mf. 1,I1t Ow B21, horiz(rn. uii(13 iu ;llnrr,y, tlln G horizolt, collt:ihl nearly 111iCra tinlce:. Tim. '1)1nlJII1 . thir l(t:eys of (11c An hop 17011 and 11 llc,ri- zolm, rrtatrl from 20 h; 4f, 11mhoz: .Irtd, in 111:1r(-s, lh(, thi(•l;.W" V011PS 9rN;lr'l3' 1`'15111 :t 5I-1101't, lrltur:l (llSt.nllrE. 1-1el,rIIL to bard roc]; mitt;, •s t'row 5 ro hurt: titan 15 fret. \IrtllNon nvrnr wirlt r!w C:e(til, (ieoreville, :1nd Llc}yd s.(AN hilt t!u}° hwo a lhwnrr Wma r:nd eoLllaiu .afore Riles flakn thou Han Y&K TI!(: 1Luli r.n -uii, ur,n(::itt less silt: thnn this Ijp,: r r!vlSte I,iis :fu(l :Irt- 111i,-I'Q :u•id 011111 the L.l03-d s01I2. Madison sanely- Ioam, 2 to r, perven€, slopes, ero. ded fAPctt12).---'.I'lli: �.itil i;; (Ill sin(>uth illfor<l••1•ealn. fiiri(lt_. Its aLIL'f;tct' 11YOV i4; if) 10 Inclwr thit:lc. N :null,- .pliwes it. i- IL nlittlrrQ Of tilt+ ivnl:linifl (Wi;:illal su frlcc soil 81Ld Of nlnteriat froill HIP lilt: les, orodoi areas; t 0 suriac:t kl,'(�r is aa.Ii; lllntrl! to 1IL'csmr11, Dili• the ('csl„r 2.2.2 Runoff Coefficient The runoff coefficient (C) is the variable of the rational method least susceptible to precise determination and requires judgment and - understanding on the part of the design engineer. While engineering judgment will always be required in the selection of runoff coefficients, typical coefficients represent the integrated effects of many drainage basin parameters. Table 2.2 gives the recommended runoff coefficients for the rational method. Table 2.2 Recommended Runoff Coefficient Values (Sources: North Carolina Erosion and Sediment Control Planning and Design Manual and 1 he City of Raleigh's Storm Drainage Design Manual, 1989) Description of Area Runoff Coefficient C Woodlands 0.20 - .025 Parks, cemeteries 0.25 Playgrounds 0.35 Lawns: Sandy soil, flat, 2% 0.10 Sandy soil, average, 2 - 7%0.15 Sandy soil, steep, > 7% 0.20 Clay soil, flat, 2% 0.17 Clay soil, average, 2 - 7% 0.22 Clay soil, steep, > 7% 0.35 Graded or no plant cover: Sandy soil, flat, 0 - 5% 0.30 Sandy soil, flat, 5 - 10% 0.40 Clayey soil, flat, 0 - 5% 0.50 Clayey soil, average, 5 - 10% 0.60 Residential: Single-family (R - 4) 0.50 Single-family (R - 6) 0.55 Multi -family (R - 10) 0.60 Multi -family (R - 20) 0.70 Multi -family (R - 30) 0.75 Business: O & 1 (1, 11, III) 0.85 11 & 12 0.85-0.95 Shopping Centers 0.85 — 0.95 Streets: Gravel areas 0.50 Drives, walks, and roofs 0.95 Asphalt and Concrete 0.95 1.00 Ciry of Raleigh January 2002 Stormwater Design Manual Page 39 Pabst Design Group, PA 9.11 Paverstone Drive, Ste. E Raleigh, NC 27615 El o X. 0 Stormwater impact Analyses 1938 S Wilmington St Raleigh, North Carolina PDG: 339-16 NOAA Precipitation Frequency & Intensity Charts) vii Raleigh Concrete, LLC S12 Nowell Raod Raleigh, NC 27607 e1 NOAA Atlas 14, Volume 2, Version 3 Location name: Raleigh, North Carolina, USA*-'"� Latitude: 35.7549°, Longitude:-78.6422° Elevation: 239.7 ft** 'source: ESRI Maps 4 '� " source: USGS POINT PRECIPITATION FREQUENCY ESTIMATES G.M. Bonnin, D. Martin, B. Lin, T. Parzybok, M.Yekta, and D. Riley NOAA, National Weather Service, Silver Spring, Maryland PF tabular I PF graphical I Maps & aerials PF tabular PDS-based point precipitation frequency estimates with 90% confidence intervals (in inchesthour)1 Average recurrence interval (years) Duration 4.90 5.71 F 6.56 7.30 5�nln (4.48.5.34) (5.24.6.24) (6.02.7.16) (6.68.7.97) 25 50 100 200 500 1000 8.06 8.64 9.16 9.59 10.1 7F 10.5 (7.36-8.80) 1 (7.84-9.41) 1 (8.26-9.96) (8.60-10.5) (8.98-11.0) 1 (9.26.11.5) 3.91 4.57 IF 5.26 5.84 6.43 6.88 7.27 7.60 7.98 8.27 10-Inln (3.58-4.27) (4.19-4.99) (432-5.74) (5.35-6.37) (5.86-7.01) (6.25-7.49) (6.56-7.92) (6.82-8.29) (7.10-8.70) (7.29-9.03) 3.26 3.83 4.43 4.92 5.43 5.81 6.13 6.4D 6.70 6.92 1 5{rttn (2.98.3.56) (3.51-4.18) (4.07-4.84) (4.51-5.37) (4.95-5.92) (5.27-6.32) (5.52-6.67) (5.74.6.98) (5.96.7.30) (6.10-7.56) 2.23 2.64 3.15 3.57 4.02 4.37 4.69 4.98 5.33 5.60 30{T1in (204-244) (2.42-2.89) (2.89-3.44) 11 (3.27-3.89) 11 (3,67-4.38) (3.97-4.76) (4,23-5.11) 11 (4.47-5.43) 11 (4.74-5.81) (4.94-6.12) 60 min 1.39 (1.27-1,52) 2-hr 0.815 (0.742.0.897) 3-hr 0.574 (0.524-0.6633) 6.346 Bar (0 317-0.379) 1.66 2.02 2.32 2.68 2.96 3.23 3.49 3.82 4.09 (1,52-1,81) (1,85-2,20) 1 (2.13-2,53) 1 (2.44-2.92) 1 (2.69-3.23) 1 (2.91-3.52) (3,13-3.81) 1 (3.40-4.17) (3.61-4.47) 0.975 1 F 1.20 1 -3 -9-T 1.63 IF 1.82 2.01 2.20 2.45 2.65 (0.890.1.07) {1.09-1.32} 11 (1.26.1.53) (1.47-1.78} (1.64-2.00) (1.79-2.20) (1.95.2.41) (2.15.2.68) (2.31-2.91) 0.6881 0.850 j 0.994 1.18 1.33 1.48 1.64 I 1.85 2.03 (0.629 0.758) (0.775-0.936) (0.903-1.09) (1.06-1.29) (1.19-1.46) (1.32-1.62) (1.45-1.79) Il (1.62-202) (1,76-2.23) 0.414 0.512 0.599 0.711 0.807 0.904 1.00 1.14 1.26 (0.380-0.455)(0.468.0.561)(0.546-0.656) (0 644-0.777) (0.727-0.880) (0.806-0.984) (0.886.1.09) (0.994.1.24) (1.08-1.37) E�](0.185-0222) (0.22-0266) (0.2075-0330) (0.322-0388) (0.83-0462) (0.4340526) (0484-0592) (0.536-0662) (0.05-0.0759) (0.662-0.845) 0.121 0.146 0.183 0,213 0.253 0.285 0.318 0.352 0 399 0.435 24 hr __]1 (D.112 .0.130) )(0.135-0.157) (0.170-0.198) (0.197-0.229)](0.234 0.273} (D.262-0.307) (0.292-0.343) (0.322-0.380) (0.363.0.430) (0.395.0.471)__ 2�lay D.07O 0.084 0.105 0.121 0.144 0.161 0.179 0.198 0.224 0.244 (0.065-0.075) (0.078-0.091)(0.097-0.113) (0.113-0.131)(0.133-0.155)(0.149-0.174) (0.165-0.193) (0.182-0.213) (0.204-0.241) (0.222-0.264) 0.049 0.059 0.074 0.085 0.100 0.113 0.125 0.138 0.156 0.170 [�:ay:](0.046-0.053) (0.055-0.064) (0.069-0.079) (0.079-0.091) (0.093-0.108) (0.104-0.121) (0.115-0.134) (0.127-0.148) (0.142-0.168) (0.154-0.183) 4�lay 0.039 0.047 07058 0.067 0.079 0.088 0.098 0.108 0.122 o.133 (0.036-0.042) (0.044-0.050)(0.054-0.062) (0.062-0.071) (0.073.0.084) (0.082.0.094) (0.090-0.105) (0.099-0.116) (0.111.0.131) (0.121.0.142) 7-day 0.026 0.031 0.038 0.043 0.050 0. 556 0.062 0.069 0.077 0.084 (0.024.0.028) (0.029.0.033) (0.035.0.040) (0.040-0.046)(0.047-0.054) (0.052-0.060) (0.058-0.067) (0.063.0.073) (0.071.0.083) (0,077-0.090) 10 day 0.021 0.025 0.030 0.034 0.039 0,043 0.047 0.052 0.057 0.062 (0.019-0,022) ( 0.023-0.026) (0.028-0.032) (0.031-0.036) (0A36-0.041) (0.040-0.046) (0.044-0.050) (0.048-0.055) (0.053-0.061) (0.057-0.066) 20-day 0.0 44 0.016 0.019 0.022 IF 0.025 0.027 0.030 0.032 0.036 0.039 (0.013-0.015) (0.015-0.017) (0.018-0.021) (0.020-0.023)(0.023-0.026) (0.026-0.029) (0.028-0.032) (0.030-0.035)(0.033-0.038) (0.036-0.041) 30{iay 0.011 0.013 0.016 0.017 0.020 0.021 0.023 0.025 0.027 0.029 (0.011-0.012) (0.013.0.014) (0.015.0.017) (0.016-0.019) (0.018-0.021) (0.020-0.023) (0.022-0.025) (0.023.0.026) (0.025.0.029) (0.027-0.031) 45{iay 0.010 0.011 0.013 0.014 0.016 0.017 0.019 0.020 0.021 0.022 (0.009-0.010) (0.011-0.012) (0.012-0.014) (0,014-0.015) (0.015-0.017) ( 0.016-0,018) (0.017-0.020) (0.019-0.021) (0.020.0.023) (0.021-0.024) 0,009 0.010 0.012 0.013 0.014 0.015 0.016 0.017 0.018 0.019 60�ay (0.008-0.009) (0.010-0.011) (0,011-0.012) (0.012-0.013)(0.013-0.015) (0.014-0.016) (0.015-0,017) (0.016-0.018) (0.017-0,019) (0.018-0.020) Precipitation frequency (PF) estimates in this table are based on frequency analysis of partial duration series (PDS). umbers in parenthesis are PF estimates at lower and upper bounds of the 90% confidence interval. The probability that precipitation frequency estimates (for a ven duration and average recurrence interval) will be greater than the upper bound (or less than the lower bound) is 5%. Estimates at upper bounds are not iecked against probable maximum precipitation (PMP) estimates and may be higher than currently valid PMP values. lease refer to NOAA Atlas 14 document for more information. Back to Top PF graphical 100.000 t 10-000 c 1.000 N C c Z 0.100 M a d n` 0.010 00" 13135-based intensity -duration -frequency (IDF) curves Latitude: 35-75495, Longitude:-78.64221 I I I I 1 1 I I I I I 1 I i I l I - ... ... ....: ... ... ... ' ... ' - 0 q v} O 0 '4 N N I�1 V r-� O O 6 �Y 6 v Duration 100.000 s 10-000 a u '�+ 1.00Q c a c c y 0.100 ra a a Gy 0 010 0.001 i 1 2 5 10 25 50 100 200 500 1000 Average recurrence interval (years) NOAA Atlas 14, Volume 2, Version 3 Created (GMT): Thu Dec 8 23:47:06 2016 Back to Top. Maps & aerials Small scale terrain Average recurrence interval (years) ••- 2 — 5 10 �- 25 --- 50 — t00 -- 200 Soo 1000 Ouration — 5-rn1n — 2- day — 10-min — 3-day -- 15-min ---- 4-day — 30-min --- 7-day -W- 60-min — lo-day — 2-hr — 20-day — 3fir — 30-day — 6-nr -- 45-day — 1241r — 60-day — 24-nr 11] E E 0 NOAA Atlas 14, Volume 2, Version 3 Location name: Raleigh, North Carolina, U5A*". Latitude: 35.7546*, Longitude:-78.6415° Elevation: 242.31 ft** ' saurse: ESRI Maps " source: USGS POINT PRECIPITATION FREQUENCY ESTIMATES G.M. Bcn^ir, D. Martin, H. Lin, T. Parzybok, M.Yekta. ad D. R.1ey NOAA, National Weather 5ervice, Silver Spring. Maryland PF tabular I PFgraphical ical I Mats & aerials PF tabular lPDS-based point precipitation frequency estimates with 90% confidence intervals (in inches)1 Average recurrence interval (years) Duration ���������� 1 2 5 10 25 50 100 20Q 50Q 1000 5 min 0.408 D.476 0.547 0.608 O.fi72 0.720 0.763 0.799 0.84i 0.875 (0.373.0,445)(0.437-0.520)(0.502-0.597) (0.557-0.664) (0.613.0.733) (0.853-0.784) (0.688.0,830) (0.7t7.0.872) (0.748.0.917) 1(0.772-0.956) 10-min 0.651 0.761 0.876 0.973 1.07 1.15 1.21 1.27 1.33 1.38 (0.596-0.711) (0,698-0.832) (0.&M-0.956) 1 (0.891.1.06) (0.977-1,17) 1 (1.04-1.25) 1 (1.09-1.32) 1 (1.14-1,38) 1 (1,18.1,45) (1.22-1.50) 15anin 0.814 0.957 1.17 1.23 136 1.45 1.53 1.60 1.67 1.73 (0.745-0.889) (0.878-1.05) 1 (1.02-1.21) 1 (1.13-1.34) 1 (1.24.1.48) 1 (1.32-1.58) (1.38.1.67) 11 (1.44-1.74) 1 (1.49.1.83) (1.52.1.89) 30�rr1in 1.12 1.32 1.57 1.78 3.01 2.19 2.35 2.49 2.66 2.80 (1.02-1.22) 11 (1.21-1.44) 11 (1.45-1.72) 11 (1.63.1.95) 1 (1.98-2.38) {2.12-2.56} 1 (2.23.2.71) 1 (2.37.2,90) 1 (2.47.3.06) 60�rtln 1.39 1.66 2.02 2.32 2.68 2.96 3.23 3.49 3.82 4.09 (1,27.1,52) (1.52-1.81) (1.85-2.20) 1 (2.13.2.53) (2.44.2.92) 1 (2.69-3.23) (2,91.3.52) 1 (3.13.3.81) 1 (3.40.4.17) 1 (3.61.4.47) 2-hr 1.63 F 1. 55 2.40 F 2.76 IF 3.25 1 F-3-.65 4.02 4.41 4.90 5.31 (1,48.1,79) (1,78-2,14) (2.19-2.63) 11 (2.52.3,06) 1 (2,93.3.57) 11 (3,27-3,99) {3.58-4.40} 1 (3.90.4,82) 1 (4.30.5.36) (4.62-5.82) 3-11r 1.73 2.07 2.55 2.99 3.53 3.99 4.45 4.92 5.56 6.11 (1.57-1.90) (1.89.2.28) (2.33-2.81) (2.71.3.28) (3.18.3,87) (3.58.4.37) (3.96.4.87) ( 4.35-5.38) (4,86.6.08) (5.28.6.69) =6-h 2A7 2.48 3.07 3.59 4.26 4.83 5.41 fi.01 6.83 7.54 (1 .90.2.27) 1 (2.28-2.73) (2,80-3,36) (3.27.3.93) 1 (3.86.4.65) (4.35.5.27) 1 (4.83.5.89) 1 (5.31-6.54) (5,96.7.43) (6.49.8.21) 12fir 2.44 2.92 3.63 4.27 5-1 7_1 5.83 f 6.57 7.35 8.44 9.39 (2.23.2.68) 11 (2,68-3.21) (3.31-3.97) (3.88.4.67) 1 (4.61.5.57) (5.23-6-34) 1 (5.83-7.14) (6.45-7.98) (7.29.9.14) (7.98-10.2) 2A�r 2.89 3.49 1 F 4.39 5.10 7 F 6.07 1 F 6.84 7.63 8.44 9.57 10.4 (2.69.3.12) (3.25-3.77) 1 (4.08-4.74) (4.72-5.50) 1 (5.60.6.55) 1 (6.30-7.37) 1 (7.00-8.22) (7.73.9.11) (8.72.10.3) (9.49.11.3) 2�lay 3.35 4.04 5.04 5.83 } 6.90 7.74 8.61 9.51 10.T 11.7 (3.11-3.61) (3.75-4.35) (4.68-5.42) (5.40.6.27 (6.37-7.42) (7.14-8.34) (7.92-9.28) (8.72-10.2) (9.80 11.6) (10.6-12.7) 3.55 4.27 5.30 6.1# 7.22 F 8.10 9.Ot 9.94 11.2 12.2 3�tay (3.31.3.81) 1 (3.98-4.58) (4,93-5.69) (5.68 6.56) (6.69.7.75) (7.49-8.70) (8.29.9.67) (9.12-10,7) (10.2.12.1) (11.1-13.2) 4�lay 3.75 4.50 5.57 6.40 7.65 8.46 9.40 10.4 11.7 12.7 (3.50.4.02) 1 (4.20-4.82) (5.19.5.96) 1 (5.96.6.85) (7.00-8.08) (7 83-9.06) (8.67.10.1)(9,53.11.1) (14.7.12.5} (11.6.13.7) jl 7�day 4,35 5.19 6.33 7.24 8.48 9.47 10.5 11.5 130 IF 14.1 (4 .07.4,64) 1 (4.86-5.54) (5.92-6.76) (6,76.7.72) (7.90.9.05) (8.80-10.1) (9.71-11.2) (10,6.12,3) (11.9.13.9) 1 (12.9-15.1) 10-riay 4.96 F 5.90 7.11 8.05 9.32 t0.3 11.3 12A 1 3-8-71 14.8 (4.65-5.29) 1 (5.54-6.29) (6.66-7.57) {7.52.8.57} (8,70493) (9.61-11.0) (10.5.12.1) (11.4.13.2) 1 (12.7.14.7) 1 (13.6-15.9) 2fl�ay 6.65 7.85 9.29 10.4 12.0 13.2 14.4 7 15.6 F 17.3 18.5 (6,25.7.08) (7.38-8.37) (8.72-9.89) (9.77.11.1) (11.2-12.7) (12.3-14.0) (13.4-15.3) (14.5.16.6) (15.9.18.4) (17.1-19.8) 8.2fi 9.7Z 11.3 1 Z.6 14.2 15.4 16.7 17.9 19.5 20.8 30 day (7.78-8.77) (9.14-10.3) (%6-12.0) (11.8-13.3) (13.3-15.1) (14.4-16.4) (15.6-17.7) (16.7-19.1) (18.2-20.9) (19.3.22.3) 45�ay 10.5 f 12.3 14.1 15.5 17.3 18.7 F 20.0 21.3 23.0 24.3 {9.99 11.1) (11.7-13.0) (13A-14.9) 1 (14.7.16.4) 11 (16.4-18.3) (17.6-19.7) 1 (18.8-21.1) (20.0.22-51 (21.5.24.3) (22.7-25.7) 60�ay 12.fi 14.7 16.T 18.2 20.t 21.6 23.0 24.3 26.1 Z7.5 (12 0.13.3) (14.0-15.5} (15.8-17.6) (17.2 19,2} (19.0-21.2) (20.4-22.8} (21.7-24.3) (22.9.25.7) (24.5-27.6) (25.7-29,1) t Precipitation frequency (PF) estimates in this table are based on frequency analysis of partial duration series (POS). Numbers in parenthesis are PF estimates at lower and upper bounds of the 90% confidence interval. The probability that precipitation frequency estimates (for a given duration and average recurrence interval) will be greater than the upper bound (or less than the lower bound) is 5%. Estimates at upper bounds are not checked against probable maximum precipitation (PMP) estimates and may be higher than currently valid PMP values. Please refer to NOAA Atlas 14 document for more information, PF graphical PDS-based depth -duration -frequency (DDF) curves Latitude: 35.7546°, Longitude:-78.6415° 30 25 C t 20 C a m 0 15 a ro a+ i3 'G 10 a a. 0. 5 0 C E -am -mu 9 -ma N A 6 ry - it1 0 Ur 0 -4 fV N f�1 V n O O O 6 Duration 30 25 C 20 y a 0 15 ra N Q. 10 as ,i 5 a 1 2 5 10 25 50 100 200 500 1000 Average recurrence interval (years) NOAA Atlas 14, Volume 2. Version 3 Created (GMT): Man Dec 12 16,54:51 2016 Back to Top Maps & aerials Small scale terrain Average recurrence inie"I (years) — 2 — 5 — an — 25 50 100 — 2D0 500 1000 Duration — 5{ntn — 2-day — 10-rein -- 3-day — 15-min — 4-day — 30-fnin — 7-day --- 50-MM — i0-day --- 2fir — 20-day -- 341r — 30-day — 6-nr -- 45-day 12-hr — 60-day — 24-Mr E e scale terrain E Large scale map � wt . �^.Y: .�. - __ .art... �-� ••-�•` _..-.....w-..ti„�71- ,Winston- �l Salein'� 0 Green 4 ti.Pr , �r ` { N6rtI I Carolina 1 �Charlotte Fayett 100km 5 60mi ! J i Large scale aerial sbaro {/ - - Rlocky ( - , ' l l� _ frn �„�Mlcxint II rrr' i �� Greenville 111 II rrr' i �� Greenville 111 Pabst Design Group, PA 911 Paverstone Drive, Ste Raleigh, NC 27615 E 0 XI. Erosion Control Calculations Stormwater Impact Analyses 1938 S Wilmington St Raleigh, North Carolina PDG:339-16 Raleigh Concrete, LLC 512 Nowell Raod Raleigh, NC 27607 E to Selection of Sediment Control Measure 1.23. Total Drainage Area Okay Temporary Sediment Trap Okay Rock Dam, Okay Skimmer Sediment Basin Okay Temporary Sediment Basin fl_46 Disturbed Area (Acres) 3.84' Peak Flow from 25-year Storm (cfs) User entry Calculated Value C = A 1 (unimproved cleared area) - Source I25 = 7 g Source; NOAA Atlas 14, Vol. 2, Ver. A = 1.23 Raleigh Stormwater Manual 3 - T = 5 minutes Skimmer Basin `Okay 0.45 Disturbed Area (Acres) 3.84 Peak Flow from 25-year Storm (cfs) 810 ; Required Volume ft a 1669 Required Surface Area ft 2 28.9 Suggested Width ft 57.8 Suggested Length It 1[48 Trial Top Width at Spillway Invert ft Trial Top Length at Spillway invert ft Trial Side Slope Ratio Z:1 Trial Depth ft (2 to 3.5 feet above grade) 27 ' Bottom Width ft 40 Bottom Length ft 1080 Bottom Area ft 2 2739 'Actual Volume ft 3 Okay 1680 Actual Surface Area ft 2 Okay M,.�. .'ri,5< Trial Weir Length ft 0.5. Trial Depth of Flow ft 5.3 a Spillway Capacity cfs 2:5 Skimmer Size (inches) 0.208 Head on Skimmer (feet) 1. Orifice Size (114 inch increments) 2.60 Dewatering Time (days) Suggest about 3 days Okay } E Ll n �J - I h 7 I r� � I I Y T'i WALKER STREET �G PLEUC R/r(!M tOM-IS1a7 __ LEGEND & SUMMARY TABLE DRAINAGE AREA DRAINING TO EX. LATCH BASINS 1.96 ACRES OPEN SPACE, POOR CONDITION � - CN89 C`.38 ACRES IMPERYIOVS AREA. PAVED CN98 ,.ley 2.09 A-RES IMPERVIOUS AREA, GRAVEL ,CN • 9t NOTES'. 1. SOILS ON SITE CONSIST MOSTLY OF Ma AND SOME ApB2, Ma SOIL ASSUMED TO CLASSIFY AS HYDROLOGIC SOfL GROUP D. CONSERVATIVELY. 2, EXISTING DRAINAGE PATTERNS SHEET FLOW WATER OFF5ITE TO EXISTING STORM DRAIN SYSTEM IN THE WTLMINGTON STREET RIGHT-OF-WAY, 3. TOPOGRAPHY PROVIDED BY PTS LAND SURVEYING, 4. CURVE NUMBER VALUES TAKEN FROM THE TR-55 MANUAL. Z a� F- h Q L a z I fl a ORA`MNG Z SHEET GRAPHIC SCALE p O ST- D I PROJECT NUMBER ( iN FEET 1 339-16 o m �J r� LL LLJ � s r9Ln U WALKER STREET fl 1 I I I LEGEND & SUMMARY TABLE IMPERV10V5 SURFACE -BUROING • 0,64 ACRES IMPERVIQUS SURFACE - ASPHALT PAVEMENT • 7,{13 ACRES IM PERVIOU5 SURFACE - GRAVEL '� .fT';f,S �'Sr • 0-57 ACRES TOTAL PRE -DEVELOPMENT • 3.3P ACRES C, Z V n ci r i � 9 � 0- 2 Li Z 'z .T V R LL Z w Z c— a Q cn z z z o O z t7 z L Zoo a "r~ J Y Z 3oLu O 0 J rn w Q1 O W IY CL o Ij _N II �3 11 �1 - a ORWANG ullj $HEST GRAPHIC SCALE PRE-N PR0IECT NUMBER �FF�I 33c- 1 iMP SP R • 0 o ra,.. �m ece an�au-m ua Mar- r. e. u.c +• zmn - n�uuam nn.erom.r. 5 \ � I , F� X -,:r -' Fz.i�,_"'� __�i��L y� -' � ,ter•._—' �1. i,.,� ♦ f 1 1 1 l �. ♦\\� `\\\ \\\�\ti \ . 1y' \ -`\ ♦ ♦ ? \-i it a y, � t\ \ ,\♦ \ \ ,. \ ', _ \ \\ ` \ 1 � uw �t nd rn Zf 1 } 4 y S Gl. r aj 3 f X NA0e3 j! LA C r��Vl7 LA s r $ V _z �nivun� ° z-z O z0npn�o� vi�nv) am0-=is�o=l G m KKN �a m 3 3�z 1�y z r aim ° 0 ° 3 mar ne 0 � zzE og 0 zyn vo Svs c71 O_A 9y � d m o o r `I 1 1 PLUM 30' PUBLIC R/ w Ql A 1 1 I = z D NO, REVISION DATE mwa r : �"�"`�'4"` 1938 S. WILMINGTON ST. CITY OF RALEIGH, WAKE COUN, NORTH CAROLINA TY PLOT PLAN PRE —DEVELOPMENT DRAINAGE AREA MAP PABST DESIGN GI-OLIP, PA Ii N I, I N li I: R I N C.ti C i7 N S U l.'I' I N C ii Fa+rrv°�E nI r sUs:�. Ra,r qn. IJo h ca,°I»a 1�61s Ph°nbrl5eas+3551c.,919eae.a;slnlcLlceNaEr,uneEa..o-3zn .nwccrucncc.: r . cn IAau waV45,w • o m r� LEI mn' Lu Z Lo ! Z I ? � o_ G _ n . WALKER STREET k}' aU6l3C v�r.( 9� 1096-•5f�) —.— •I INTERSTATE - 40 260' 'WL4 R, w s 19wE ...) �I ' f iA A5H4ALT RAVE -ENT ApEA • O 2- ACaES f {i 1 Lu ! i 1_Q TUTAL Aaowsao - l!) BU10ING AftA - OUTA"E5 r i LEGEND & SUMMARY TABLE IMPERVIOUS SURFACE -BUILDING • 0.1 ACRES IMPERVIOUS SURFACE - ASPHALT PAVEMENT • 0,24 ACRES ` �' X/. IMPERVIOUS SURFACE - GRAVEL �j>•.' - 2.19 ACRES IMPERVIOUS SURFACE -CONCRETE PAVEMENT • 0.14 ACRES TOTAL POST -DEVELOPMENT = 2.58 ACRES NOTES: }, ALL IMPERVIOUS GRAVEL. 8WI-DING, AND ASPHALT AREAS ARE EXISTING ON SITE. THEREFORE, THE ONLY PROPOSED IMPERVIOUS AREA IS THE CONCRETE PAVEMENT AREA, WHICH 15 REPLACING EXISTING GRAVEL AREA. a Q F- L7 un z Q Z a Q z 0 p c J V S c LL! _ 0 Doa F- w F- Z J 0 r Z a w 0 0 oc)W O LLI rrn > LLJ rn ❑ �— I F- Ln 0 a 0 N K O z ----------- DRAWING SHEET GRAPHIC SCALE POST-N mlw ' PROJECT NUMBER I . IEET 1 339-16 • 0 Property Owmer Cartirrcate for NONZEDiCAT1OM (This includes Boundary surveys and Reconbnat on palls where no easements are being astablis,W) Property Owners Cerfihute {Boundary and Recombination Plats): This centraz and warrants ftt the undersigned Is (are) phis sde twnw(e) of the Properly shown on the map a plat and any aom parrying sheets having acquired the property In fee stmpie Cy deed(,) recorded in the minty, register d deeds offs where the property Is located and as such has (have) the rkyu in convey the properly r roe airnpe. Book No,: 15112 Page No.: 97 Signabre(s) 8 u5erpas6ort of Property or„nelisi: I/�' If , // yf,� a "a,-iian l 1 C- by l LA—V ,WC4 rlloi-h&l IrJrr4'�' r STATE OF 1i-s C�' [4 COUNTY I certify that the lfolkmng person(s) barsonaay appeared before me this day, w*nowledg9g to ern thal he or she vo(untanty taegurlig purpose stated therein and in the capaary ntlkatad �+' I Printed My pomrtrission FLOOD PLAIN ORDINANCE M FIRM PANEL 372001702 1 1 OTHER /'y� i ed By:! ! qg,r1/ I 7 5 THIS PLAT NOT TO 8E RECORDED AFTER =7 DAY 0F_21,' V/ 1 COPY TO 8E RETAINED FOR THE CITY. THIS PLA T 15 Q) ]NO OU T OF THE CITY LIMITS, SURVFY NQTES: 1) The basis of oath is NAD "2311) tram a VRS. GPS survey. Vertical Datum is NAVD 09. 2) Apr distances are horizontal ground dmtanoas. unless noted eVor—e Ar eas aas coagxsed by Coordinate geometry. 4) Tim survey dots not wx*jde nor depict arty envxa tad avakratians except as stown- 5) original field surveya aawlametl on July 8 6 July 7, 2011. 6) Flood Inbrmatkon: Portions of su"d parcel are o®ted In special flood hatertl x,rles per Flood Insurance Rate Maps 37200170200J 8 3720.1703.00J, Dated May 2, 2006. 7) 3W iron pipes found or set at all I>m�crty corners unfesa otharwise n otod. 8) Surveyor has made no 0hesugatbn or independent search for ass—Tantsof record, enamarbnt s. reEaY9ve omrsantl, owner31M7 idle a'nd— ar any other facts that an aco rauf and ohnsd title search may disclose. 9) All casements, nghtof-ays. buff— setbacks and adjoin"'. etc - referenced from Ptat Bock 19%. Page 1529. oerawkse noted. 10) The orations of under"" are based upon visible surface evidence and records provided by the owner. No excavatioM were made during the process of this survey to kxate buried utftes and I or sbudures- Undergound unity markig was rho(req sled or performed by "CBI l Or other sources for the purpose of this survey- Additional ut3ibi,, nlay be enc untemel All underground utilities shard be held located by the apprwda ubfrty company. prior to any oenstructon or excavation on or adio"nl o the subject property. 11) Temporary sore pies of materials were rhd surveyed. 12) Storm sizes and connectivity, from Wake GIS. 13) The blebmard lease area is pending receipt o1 2013 Survey referenced n DR 152115, Page 731. 14) 'Remrmbihed Properties are slbjact to Soomsvater Regulations under Ankle 9.2 of the U00'. Is) Stnnl Ia review has acm-pled the grdveNmporVjo.5 area under Transamon a T-1G46W. ;I�r i I PARCEL INFORMATION Recombination Certificate Curtenl Owner: Rake" Reclamation LLC 'This pat or maP Is not a subdi isim, but a n?comCinaVon of prsmusty . d - - Source of Tale: Dead Boon 15112. Pape 197 plated property. and meets ad statutory raquveam-As for recordng' f . I wake County Pin; Pins: 1703.60.11B1 d t702.69.1912 rl B61 ZOnI 4n IH W15HOD-2 f11:AO Pynrvng and Da mbp—rrt OffoafiNake County Review Officer T— — — —1 4 I DNS to/714 I w j Vicinity Map g Lu I chre sm.l Lu 2 vi .gyp I ! site i.7r'rlror Puff J� NAp aS(70}S) N-ZX2=67 GZ.ID6.41Q62 `r .-..._..—.._.._..... — WALKER STREET agar eF�a^a�w�w' Jo' weuC R/w(su Taos-f52e) N a9'4p'M- f 430.80' ! I r — /^ 1 - 1 d N�E RAf�1GN %rrQ7 T'; RECLAMANGN LLC DS 75112-)97 LOT 8, BM .996-1529 hI PIN: r703.60.Ir61 r1orA Mood d • a f RET.I I ZONINQ rH W/5HOO-2 iz A.mvAL C.A. p0m; I !r 367,045 S.E., 11.539 Ac. i i FOMEMY 1923 i llruwrar sr. r v` ON] L f rl-rA hoop COa 7MMS ! r A t C / 02X ANfN1M- alANOr r i 1 1Z r ' 1 J OLD LOT LINE IE ST RELpI ,� — — JO' AGCFSS GSE — N &a�4i'mF ro7.er/ norIV - / NEW LOT 1 °g ► 22��LO�,` I i wQr RALEIGH RECLAMATION ±165,855 S.F., t3.81 Ac. ' USE: WASTE RELA TFO 10 $ SERNCES / 1 1? S rr d Z 2 rl. RE0.A A"ON' LLC 44= 3 I ' APPROxIMATE 09751 r2-197 LOT A, BM 1996-1529 a LMITS OF 1 / ' PIN: 17W 50.8002 • N/i RALE1rif GRAVEL i t t '� RECLA"ATTPN LLC 1 i j ' D8 15112-r97 , , 1 1 /• LOT G 91v ;996-15Z9 it1 MM.1702.69. M2 ZOWNG IN WIDIM-2 f 1 1 f d WAKE COUNTY, HC 22 RIDDICK t98,8fO S.F.. 12.26a AP. -4- l' 1/ 1 LAURA 11 REGISTER OF DEEDS / PRESENTED S RECORDED Oil 10/10/2016 09:54:04 a i inloomilmlii,mNall , r I atLB0ARVx h I/ae Is2os-731 �' �. 8DOK:BN2016 PRGE:01695 h R5 , — lIRS; N 8751'Oa' F ral.)1' _ / s a9~Vt'41' E Tie, or J a 0N. r•L Don 1{ ALOW e r \APPROxINA • 5 j4� 30 a� TE INTERSTATE • 4D U N/F RALErC+f o RECLAMA PON LC / LIMITS OF 250'FLG® R7rtaN la9rf-I52g DB 1575.5-710 ,^G / GRAVEL -089 ACRES', 1996-9852152 / q,1' � ash 1202-59-676 9 ,e ., ,•}3=a * NApCiy;n6r.0 Poi/IT I¢{ 5 T �ni9e 0W �MAMU P�V15 IPS I— Poe set IPF4tF: I lam. P CP 5 man e Electri 1 N stiff L' ht e fuF N—or GP Calal:aled 1 ww R" f -ova er De Deed 1306, _x_I Aram a'erhead util RhY C re 4 Ralph V. Pen"aph Jr-. PLS. comfy that this map was drawn urrdes my supennsiorl from an actual GPSrGNSS auvey or do made under my supervision end the kAhwn g nformhetion was used to perform the survey: Clan.s of survey: AA Pu>srtiand .=racy @ 95% Coned— H:0.023% V: 0 098' Type of GPSIGNSS held procedure: RT1(1 NCVRS) Da*.) of survey: OS26, 07MIS 8 07107M I6 DaturTwEPodh: NAD ON2011) epoch 2010.00 Pudished+hxed control: NCVRS Network Combined Facso: 1.00009575a452 Unts: tTS Survey Fad HorLronlal powbons ere KAD831NSRS 2011 Vertical Datum is NAVD W SURVEYOR'S CERTIFICATION I certify fiat this map was drawn under my supervision from an actual survey made under my supervision (deed and description recorded n Books referenced): that ire bandanas not surveyed are dearly indicated as drawn from intormabon fond in Uooks referenced: that the ratio Of Predsial Or amoonal accuracy as calculated exceeds slandardl: That this Plat wee Prepared in accordance with G.S. 47-30 as amendend. I Partly b the fop,": Tut cos survey is a her- oxnabon col en+a4hg penman "does not cream any Thew toe or rights d ways wrtness my original signature, registration number and seat this 4m day of October, 2016. TRANS. # 484789 CASE M R-114-16 P� oil o ��13 ZONING CASE M Z-27B-14 8t Z-27-87 rum ejr201 s GPMHIC SCALE 0 5 50 100 I IN FEET I v N�•AM1 REVISIONS 08119r2015 Pre -submittal review 00P1272016 lu subnettal 09f29R016 1st Submittal revisions 10/04MI6 Mytar submnaVmVm,, Recombination Plat of: 1928 & 1938 South Wilmington Street Raleigh, NC "New Lot 1 Raleigh Reclamation' Lots 88C O'Neal Family Partnership Book of Maps 1996, Page 1529 heed Book 15112, Page 197 Pins:1703.60.1181 6 1702.69.1912 Raleigh Township Wake Couinly, NC Prepared for: Raleigh Reclamation, LLC Contact: P. Dan Pabst, PE 911 Paverstone Drive, Suite E Raleigh, NC 27615 Office: 919.848.4399 Pmr� Land Survetjng PO Box 726 • Apex, NC 27502 Phone: (919)625-69W www,ptsno.00rn PROJ. # 16013 October 4, 2016 A E. L I WLij m co I � a -/1'I• WALKER STREET PUBIC iAYaI lows vi t) S [ — % -- % --�. % t _ — [.���, [— , [ �� '[ �...'. [ ---- �.....! .�.�-- Y .�—• Y [ ,( _r - 'C .—d+- [--K--�= K •_-- X �.-� - /1!'NF ; 3"a_C; Sa : a5C tN^ I,M1� 9s51 — — icy — — k 77'SI:Y9" E — I I 1 1 It / • WE aALEIGN AECL[MAIION LLC / `" -. , L^.i i. fll'I 20151695 / r •' j ' PIN 170159193E � 111 � , I{ � 5E.8535E. .3.814C /. /.. - I + i �� / �;= / �/�.r—.f- � ;r _ _ - I • - ;ter 23 ACRES � IrV'' •r I I :z . I Lo - X:+.'f/f t�" if � -� �� � �� y� � I I f'� j/%I tJr/�iJ�j P• � z � �J4 . 4 - �%f" � f � i � �o'/ f / �M1 i. -., f ,ul.�" 7' I! y ''�•j:, �a..e�'� . .i S R O -01 w W 1 INTERSTATE- 40 r al LEGEND & SUMMARY TABLE DRAINAGE AREA TO SKIMMER BASIN �t C ACRES LAWN AREA C-0.-C.2c / ff 0-79 AC R E5 GRAVEL AREA C,14 ACRES CONCRETE AREA. •{r�C, •. y4 C-0.95 COMPOSITE C VALUE = 0,72 NOTES: 1. C VALUES TAKEN FROM Clay OF RALEIGH STOPMwATER DESIGN MANUAL. Zi GRAPHIC SCALE I Ik EEEI I 1 rMn-inn S7 20 L LLJ z ZCf O a a Lu LD z zQz '¢ J _j°O w a � p z v o 0 00 V O ry) O� U) O W DRAWING SHEET EROS-Di pROJECP NUMBER 339-16 co c • WAKE COUNTY. NORTH CAROLINA — SHEET NUMBER 59 _V f K 59 N c, v F, / A 0 .T ER ST. SITE U z i s BELTLINE 0 0 THIS IS NOT A SUBDIVISION BUT A RECOMBINATION 4PREVIOUSLY PLATTED PROPERTY. CHAPMAAN - DATE 3 ECTOR OF PLANNING THIS PLAT N9T TO BE RECOR ED AFTER ---------- DAY OF W q_(_ 1 COPY TO BE RETAINED FOR THE CITY. THIS PLAT IS _ __ IN __-_ OUT OF THE CITY LIMITS. VICINITY MAP IN.T.S.I NORTH CAROL]" - WARE COUNTY THE FOREOOIIIG CERTIFICATE Nance P. Cwpar NOTAI ITN CIESH 15 IA10 CERTIFIED TO BE C IRECT. TNIS INsT10BEN7 WAS PRESENTED FOR REAM013TRATION ARECORDED IN THIS '-O�F�FICE,. THIS 74114 DAY OF OC+Dkle-r II AT 10•. 7-R O'CLDM, „A- M. WEMETH C. WILEINS. REGISTER OF DEEDS BY SyL0. S . p-ir jamdSQ,,\_ DEPUTY REGISTER OF OxEOS 'I. THE UDERNOPED PLANNING DIRECTOR OF THE CITY OF RALEIGH. DO NFAEBY CWt" THAT THE Cl" OF RALEIGH. AS PROVIDED BY Cis CITY CODE, DR THE OAT OF IN THE YEAR APPROVEG THIS RAT OR MP AD A.C.AC4T]PSIEETS. AHD ACCEPTED FOR THE CITY OF RALEIGH THE DEDICATIONS AS SHOW THEREON. BUT ON THE FURTHER CONDITION THAT TIE CITY ASSI.ES NO RESPDNS:BILITY TO OPEN OR MINTAIN THE SAME UNTit IN THE DISORETIOR AND MINIM OF THE CRIERNING BODY M THE CITY OF RALEIGH IT IS IN THE PUBLIC IWEREST TO DO SO. PLANNING DIRECTOR STATE If NVTrH C RNA. �eO�hn�N 1/ h CORITT I. O y .��JJ NOTMY PUBLIC DC HERESY CERTIFY THAT PSQkALLY IV. / APPEARED BEFORE NE THIS DAY AND ACKplMEDICED THE DIRE y, EXECUTION OF THE FOREGOING INSTRUMENT. WITNESS NET wNy j OFFICIAL SEAL, THIS DAY OF p�..'•-•'•� 'P QrGrtj 2: �pSARr NOTARY PUM IC 'S rUBL`L V Mr mN[ss[ol E IRIS , -�� ^+ ,••, r= THIS CERTIFIES AND WARRANTS THAT THE uDEJSIGNEp IS CARET THE •'ySTQ dV�.•' SOLE MINERISI OF THE PROPERTY SNOW ON THIS MP SUBJECT TO THE ,~GRAN•, u NN•� EXCEPTIONS ON RECORD . EC RD. HAYING ACQUIRED THE PROPERTY IN FEE SIMPLE BY DEEDISI RECORDED IR THE OFFICE OF THE REGISTER OF OS OF WARE CONTY. NORTH CANXINA OR OTHERWISE AS SHORN BELOW AND AS sum. PINS IHAYEM THE RIGHT To CONEY THE mKrERTr IN FEE SIMPLE. AND THAT THE DEDICATORRCSN WILL WARRWT AND DEFEND THE TITLE A",W THE LAWFUL CLANS OF ALL PERSONS gDP6OEYER UNLESS ExCEPTm muE01 AND THAT BT 5MMISS101 OF THIS PLAT OR IMP FOR APPROVAL. I IWe1 00 DEDICATE TO THE CITY OF RALEIGH. FOR THE PUBLIC RISE ALL STREETS. EASEMENTS, RIGHTS-DF-WAT. PARKS AND GREENWATS 3,0W THEREON FOR ALL LAWFUL PURPICE5 TO MICH THE CITY MY DIME OR ALLOW THE SANE TO BE HSEO AND IPOk ACCEPTANCE THEREOF rR ACCORDANCE WITH ALL CITY POLICIES. ORBIINANCEE. RECLLAT[on m CODITIOO OF THE CITY OF RLLEICN FOR TIE BENEFIT OF M Full IC. SAID GEDICATTOM SHALL BE Utff ABLE PROYIOED ANY Om2CAT POI OF M EEMOITS FOR SHORN ORAIMCE ARE NOT MADE TO THE CITY OF RALEIGH BUT ARE IoiYOCAALT M�OE TO THE SUMONT OWNERS OF AM AND ALL PROPERTIES SNOW HEREON FOR THEIR AGE AID BENEFIT SUBJECT TO 6OIDITIONS OF SUB SECTIOO IWI. I.I. I.11 AND ITN OF SECTION I AND SECTIDN 4 OF THE CITY STORK DRAINAGE FOLICY IRESOLUTIDN 197 -T42 A$ TIRE SAME MY BE FROM TIME TO TIME AENDED"a Om_ PAGE 316WA IIJJJ`/ BO00- PACE SIGNATIAF -, STATE OF HORN CARO.INA. JOHNSTON CONY I. A NOTARY PUBLIC OF THE COUNTY AMC) STATE AFORESAID, CERTIFY THAT C. THE NTATY. JR.. A REIE THIS ISREI¢UR D LAND SYEYM. PERSONALLY APPEARED BEFOE HIS DAY AND ALKADREOCED THE DIE EXECMRT I ON OF THE FORE COIN IPNSTRIAEM. WITNESS IR NAND OFAl. AND l ILL SETHIS DAY OF - ��Mlil r l Q �pEq . ,EEG. ► �,ptARY (OFFICIAL SEAL OR ST.AP) B • $ $ NUT4JtY PUBLIC PUSLIC rt COMMISSION E17IREs 13-W-R] },y ...,_.L {j� 'I. C. WAYNE HYATT. JR. . CERTIFY MAT THIS PLAT WAS ,~ TOh CN . DRAW UNDER WV SUPERYtV FROM AN ACTUAL SURVEY MAOE UNDER NANNPMIAN HIT APER1'13 POI. COILED DESWIPTIO. AS REFERENCEO NEREONI GNAT THE BOUNDARIES IWT SOIYETM ARE CLEARLY ]IDIUTED AS DRAW FRON INFO2WTIOH AS REFEREW= NVEONN THAT THE RATIO OF PRECISION AS CALCULATED 15 1 .10,000 " THAT MIS RAT WAS PREPARED IN ACCOROAM WITH N.C.C.S. I7-30 A$ AMENDED. AND. THAT THE 2AVEY S OWN HEREON IS A CATEGORY (dI OF SUBOIYt SIGN (11) OF SIMISECTION ITN OF H.C.C.S. 47-30, WITNESS �NT ORIGINAL SS �IG�NAATVE. REGISTRATION NUMBER AID SEAL THIS _0_-- DAY OF �,ucrola$it � RECORDED A.D.. 1196. SEAL OR STAMP Hl REFERENCES: BOM 1987, PG 181 V LEGEND: DB 5067. PG 387-399 BOW BOOK OF MAPS m NWFS NO MONUMENTATION FOUND OR SET PG PAGE NOTES: OB DEED BOOK z 1. ALL OISTANCES SHOWN ARE HORIZONTAL GROUND DISTANCES. UNLESS RAW RIGHT OF WAY OTHERWISE INDICATED. NTS NOTATo SCALE H 2. PROJECT NUMBER: 960820 8 EIP EXISTING IRON PEPE 3. DRAWING FILE: 9608202d.DGN NIP CLF NEW IRON PIPE CHAIN LINKED FENCE z z' 4. PIN: 1703.1950-9036 OHE OVERHEAD ELECTRIC o 5. PROPERTY ADDRESS: 1938 S. WILMINGTON ST. FH FIRE HYDRANT 6. TOTAL ACREAGE : 6.68 -OP- OLD PROPERTY LINE tl T : Z0NF_0:JND-2 WITH SHOD-2 z -� WALKER ST. (30' rr ------- Town'--------- •�--- ^------ �-- o,E... -..--�--------�--------------^--- R/W) Lp ---- ----- DATE N89.39' 33'E 715. 68' 4' IILF ' ONE -------NLF PF en- ----�DisTIuiBED - NIP _ 430.a6, 0E---- .fir !• I } IEIP RESET 201 WALKER 5T. [ BuaDlxG1 284�82' { I II I I I I I { I I 101 WALKER ST I I I 4eR II ` I II ,,I II I I I I �!1 I fit) I Rs0} I I59) o s�ISG) --I - f3) { ASS) {- 1!s) - �- ��,) In I!2} 1!1} � ISO) 1`s) {- IA) -T- 1-7) � uE) Ins) \ ti2V j �e� I '� I I- I I I{ I I I- I I I I- I 0r JONES A RwELL S/0 ! JOSS A. POWLt S/0 { I K I JOES . POWELL IS/D I I LF, J• I r tto.99' ELF j L L i L- --OP- SL1S�LLOP / i' IRON BAR Na9'46 42xCLF x-}---I-i-�OP;I T-o~O �- tr BUILDING it.tW, �ry Ir I EXISTimT [ ^I�a I I LOT B - - - I BODY SHOP 0 I s 1.54 ACRES SR. L► PP7 ! Iolvai I n NIP 10T.61' NIP -11-- �L se9.59 24 x J -------�-- 2p' WATERLINE I cn 30, Acc�si --�! S89'27'51'W --- -- J F-_� NEW o�ERry z7J EASEMENT - r$ • h 253.24_�----- I_ i ,. s�4.'.t oo f ACSHED__ 0ACCESSLP W 1 y IsFA"WENT I AREA OF 30' EASEMENT = 0.36 ACRES = 15697 SF ! IRA I OI r 1 I B' CLF �Y 11 % x N 1 -'1 A GATE SLON BRZCK i 1 I N1 I a7 WALL WALL I 1 ' 7N i(ti �- {�� NOW OR FORMERLY / p ?� O'NEAL FAMILY PARTNERSHIP !I 0 LOT C i w �N 115.20' EIP 7I LOT A PIN : 1703.19-50-9036 = a 2.27 ACRES BUILpNNG ry �� ELF N87.49 1 •' LLF 2.11T ACRES DS 5067. PG 387 ! 6.01 ACRES e a 4 % RAFTER RECOMBINATION eutLplNeer I 7 y ON INCLUDING 30' EASEMENT) 1' O I 1 0 gl� o. I F � �' ¢ n tB, 7 0IN ' I / W BILLBOARD N ^OF A rP 4 IV I CLF GA -1 Lt x 7.4916E-270.39' NIP --OP-- 330.60' �.-- ----' ---R/W T, ,' S11.63' / M� N` 144.1 ElP$ 11 ELF ELF e9.16' N M N88.06 53 R_- , `. -! �3----0HE_ NIPNOW +N87•55'2t'� OR FORMERLY MARION C. PENNY I NOW OR FORMERLY RR PP S' C0 S�A A6 -----^- - _ PP LP J DB 2074. PG 349 I 2100 S. WILMINGTON O'NEAL FAMILY PARTNERSHIP o C63F- I PIN 1 1702.07-59-9708 ; i NOW OR FORMERLY ti : •; Iy'R NCGS MONUME13NUME '0'NEAL' O'NEAL FAMILY PARTNERSHIP A9 A• 8NT186 N = 72 li r. PIN 1702. 0T-59-7716 PP e' R� E = 2.106,591.24 (NAD 831 a1�Wf N OB 2438 PG 472 4 4fl �'j,6 ELEV - 269.30 (NGVD 29) - IB • �IN • - Rye S4R�. of AT•ji CZRM • t1. Sz DISTURBED $ 1 ELF RESET Pp I S0 S2 � E[Pd+ S7 60 0 60 120 160 GRAPHIC SCALE 1' - 60, IN BOOK OF MAPS i 9 9 ( PAGE (5Z9 WAKE COUNTY REGISTRY. DERWARD W. BAKER d ASSOCIATES. P.A. -REGISTERED LAND SURVEYORS- 1500 PINEY PLAINS ROAD SUITE 102 CARY. NORTH CAROLINA 27511 (919) 460-0075 SCALE 1' - 60' DATE 8/27/96 SURYEY FOR, UNEAL FAMILY PARTNERSHIP CITY CF RALEIGH. WAKE COUNTY NORTH CAROLINA $M ET � FLO. 9K. &PAGE, N/A DRA%WBY2 Cw 13F FILE HO.I 762 CHECKED 9Y, DWS OP B NEW PROPERTY LINE. CWH COWOSITE/RECOMBINATION MAP REVISION BY FJ RALEIGH CONCRETE LLC TEL. 919-803-0781 FAX: '919-803-1344 PO BOX 551 RALEEIGH, NC 27602 -.• ..` � 'p'��1;�... T�� __ __ .. �,Ma,.�w �_r$'w�tY�,'?.N,x-'...:»S��w� _. ��:'�$ L.,�Aa� i ._?r DIY r' 3756 WELLS FARGO BANK, N.A. _ 6&211 O WELLSFARGO.COM + . 6/25/2018 oR� o� TO TNCDEQ sir100.00 One Hundred and 001100rrtrrttttrtirtrttrrttrtttrtttii•rirrtrrrrtriirttrritirtirttiiiiriitiaiitiittriitrr►rrearriarraatrrrt NCDEQ 1612 Mail Service Center rt cow NC 276 9a; Raleigh 9 MEMO stormwater permit n� 118003756110 ` O 0 TOTAL NITROGEN IMPERVIOUS SURFACE REDUCTION SUMMARY Project 1938 South Wilmington Street Calculations by Project No. 339-16 Checked by Location 1938 South Wilmington Street Date SA B in 13-Dec-16 THE FOLLOWING TABLE SUMMARIZES THE AMOUNT OF IMPERVIOUS SURFACE IN EACH SUB -AREA FOR THIS PROJECT, BOTH ON- SITEAND OFF -SITE IN ORDER TO DEMONSTRATEAN OVERALL REDUCTION OF IMPERVIOUS SURFACE NOTE: ALL UNITS IN ACRES PROJECT PHASE ON -SITE PRE- DEV E30P. 3.2 POST- DEV FLOP, 2.58 NET CHANGE -0.62 0.62 NET CHANGE IMPERVIOUS (AC) FINDINGS: IMPERVIOUS SURFACES SEE A NET DECREASE FOR THE PROPOSED IMPROVEMENTS. ACCORDINGLY, SINCE THE PROJECT REDUCES NITROGEN LOADING COMPARED TO PRE -DEVELOPMENT CONDITIONS, THE DEVELOPMENT IS NOT SUBJECT TO ANY FURTHER NITROGEN REDUCTION OR BUYDOWN PAYMENTS. Stormwater Impact Analysis For 1938 S. Wilmington St City of Raleigh, North Carolina Submitted to: City of Raleigh Public Works Department Stormwater Utility 22 West Hargett Street Raleigh, North Carolina 27601 Prepared for: Raleigh Concrete, LLC 512 Nowell Road Raleigh, North Carolina 27607 Prepared by: PABST DESIGN GROLIP, PA LNCINI_EK I NG & C0NSLlL'I INC. Date: December 13, 2016 PDG Project No: 238-13 Sr p �1RB 2018 �RMwA4R pE�qC/n, Mrr7lft 911 Paverstone Drive, Suite E - Raleigh, NC 27615 — Phone 919.848.4399 Fax 919.848.4395 Permit wCo ».°= aim elk; W, nciffRaw, fill gl,7 xj.:; WWI It , qw, NPDES Stormwatet Program Permit PERMIT NUMBER NCG140463 dW 'All a �,Lp.z I F i� Q, 4 V" f! j I . GAP Op gpix man 111� 3 Hydrograph Report Hydraflow Hydrographs Extension for AutoCAD® Civil 3D® 2014 by Autodesk, Inc. v10.3 Wednesday, 12 / 14 / 2016 Oyd. No. 1 Pre-Dev Drainage Area Hydrograph type = SCS Runoff Peak discharge = 26.58 cfs Storm frequency = 2 yrs Time to peak = 716 min Time interval = 2 min Hyd. volume = 57,810 cult Drainage area = 6.160 ac Curve number = 94* Basin Slope = 0.0 % Hydraulic length = 0 ft Tc method = User Time of conc. (Tc) = 5.00 min Total precip. = 3.42 in Distribution = Type II Storm duration = 24 hrs Shape factor = 484 " Composite (Area1CN) = [(3.630 x 98) + (2.010 x 89) + (0.520 x 91)j 1 6 160 Q (cfs) 28,00 20.00 16.00 12.00 4.00 Pre-Dev Drainage Area Hyd. No. 1 -- 2 Year 0.00 • D 120 Hyd No. 1 Q (cfs) 28.00 24.00 20,00 16.00 12.00 4.00 WNWATOI 240 360 480 600 720 840 960 1080 1200 Time (min) Hydrograph Report 3 Hydraflow Hydrographs Extension for AutoCAD® Civil 3D8 2014 by Autodesk, Inc. 00.3 Hyd. No. 2 Past-Dev Drainage Area Hydrograph type = SCS Runoff Storm frequency = 2 yrs Time interval = 2 min Drainage area = 4.430 ac Basin Slope = 0.0 % Tc method = User Total precip. = 3.42 in Storm duration = 24 hrs . Composite (Area/CN) = [(1.960 x 89) + (0.380 x 98) + (2.090 x 91)] / 4.430 Wednesday, 1211412016 Peak discharge = 17.68 cfs Time to peak = 716 min Hyd. volume = 37,169 cuft Curve number = 91* Hydraulic length = 0 ft Time of conc. (Tc) = 5.00 min Distribution = Type II Shape factor = 484 Post-Dev Drainage Area Q (cfs) Hyd. No. 2 — 2 Year Q (cfs) 18.00 18.00 15.00 15.00* 12,00 12.00 9.00 9.00 6.00 6.00 3.00 3.00 0.00 - 0.00 0 120 240 360 480 600 720 840 960 1080 1200 1320 Na. 2 Time (min)*Hyd 4 Hydrograph Summary Report Hydraflow Hydrographs Extension For AuloCADS Civil 3D® 2014 by Autodesk. Inc. v10.3 Hyd. Hydrograph type (origin) Peak flow (cis) Time interval (min) Time to Peak (min) Hyd. volume (tuft) Inflow hyd(s) Maximum elevation (ft) Total strge used (tuft) Hydrograph Description 1 SCS Runoff 39.99 2 716 89,482 ---- -- ------ Pre-Dev Drainage Area 2 SCS Runoff 27.47 2 716 59,448 — - — — --- Post-Dev Drainage Area SIA_12-13-16_SAB.gpw Return Period: 10 Year Wednesday, 121 1412016 Hydrograph Report 5 Hydraflow Hydrographs Extension for AutoCAD® Civil 3D® 2014 by Autodesk, Inc. 00.3 Hyd. No. 1 Pre-Dev Drainage Area Hydrograph type = SCS Runoff Storm frequency = 10 yrs Time interval = 2 min Drainage area = 6.160 ac Basin Slope = 0.0 % Tc method = User Total precip. = 4.96 in Storm duration = 24 hrs Composite (Area/CN) = [(3.630 x 98) + (2.010 x 89) + (0.520 x 91)] 16.160 Wednesday, 1211412016 Peak discharge = 39.99 cfs Time to peak = 716 min Hyd. volume = 89,482 tuft Curve number = 94* Hydraulic length = 0 ft Time of cone. (Tc) = 5.00 min Distribution = Type II Shape factor = 484 Pre-Dev Drainage Area Q (cfs) Hyd. No. 1 -- 10 Year 40.00 30.00 20.00 10.00 Q (cfs) 40.00 0 30.00 20.00 10.00 n nn 0 120 240 360 480 600 720 840 960 1080 1200 No. 1 Time (min)*Hyd Hydrograph Report 5 HydraFlow Hydrographs Extension for AutoCADS Civil 3D® 2014 by Autodesk, Inc. 00.3 eyd. No. 2 Past-Dev Drainage Area Hydrograph type = SCS Runoff Storm frequency = 10 yrs Time interval = 2 min Drainage area = 4.430 ac Basin Slope = 0.0 % Tc method = User Total precip. = 4.96 in Storm duration = 24 hrs Composite (Area/CN) = [(1.960 x 89) + (0.380 x 98) + (2.090 x 91)1 / 4.430 Q (cfs) 28.00 16.00 12.00 4.00 0.00 -E i0 120 Hyd No 2 Wednesday, 12114 12016 Peak discharge = 27.47 cfs Time to peak = 716 min Hyd. volume = 59,448 cuft Curve number = 91" Hydraulic length = 0 ft Time of conc. (Tc) = 5.00 min Distribution = Type II Shape factor = 484 Post-Dev Drainage Area Hyd. No. 2 -- 10 Year Q (cfs) 28.00 24.00 20,00 16.00 12.00 4.00 0.00 240 360 480 600 720 840 960 1080 1200 Time (min) 0 Hydrograph Summary Report Hydraflow Hydrographs Extension for AutoCAD® Civil 3D® 2014 by Autodesk, Inc. 00.3 Hyd. Hydrograph Peak Time Time to Hyd. Inflow Maximum Total Hydrograph No. type flow Interval Peak volume hyd(s) elevation strge used Description , (origin) (efs) (min) (min) (tuft) (ft) (tuft) 1 SGS Runoff 47.84 2 2 SCS Runoff 33.21 2 716 108.336 716 72.817 Pre-Dev Drainage Area ------ Post-Dev Drainage Area SIA_12-13-16_SA$.gpw I Return Period: 25 Year I Wednesday, 12 / 14 / 2016 Hydrograph Report 7 Hydraflow Hydrographs Extension for AutoCAD® Civil 3D& 2014 by Autodesk, Inc. v10.2 Syd. No. 1 Pre-Dev Drainage Area Hydrograph type = SCS Runoff Storm frequency = 25 yrs Time interval = 2 min Drainage area = 6.160 ac Basin Slope = 0.0 % Tc method = User Total precip. = 5.87 in Storm duration = 24 hrs * Composite (Area/CN) = [(3.630 x 98) + (2.010 x 89) + (0.520 x 91)1 16.160 Q (cfs) 50.00 I * 40,00 30.00 20.00 10.00 Wednesday, 121 1412016 Peak discharge = 47.84 cfs Time to peak = 716 min Hyd. volume = 108,336 cuft Curve number = 94* Hydraulic length = 0 ft Time of conc. (Tc) = 5.00 min Distribution = Type II Shape factor = 484 Pre-Dev Drainage Area Hyd. No. 1 -- 25 Year n nn i 120 240 360 480 600 720 840 Hyd No. 1 Q (Cfs) 50.00 40.00 30.00 20.00 10.00 rri, 960 1080 1200 Time (min) Hydrograph Report 7 Hydraftow Hydrographs Extension for AutoCAD@ Civil KM 2014 by Autodesk, Inc. 00.3 Hyd. No. 2 Past-Dev Drainage Area Hydrograph type = SCS Runoff Storm frequency = 25 yrs Time interval = 2 min Drainage area = 4.430 ac Basin Slope = 0.0 Tc method = User Total precip. = 5.87 in Storm duration = 24 hrs " Composite (Area1CN) = [(1.960 x 89) + (0.380 x 98) + (2.090 x 91)] 14.430 0 (cfs 35.00 30.00 25.00 20.00 15.00 10.00 5.00 Wednesday, 12 / 14 / 2016 • Peak discharge = 33.21 cfs Time to peak = 716 min Hyd. volume = 72,817 cult Curve number = 91 Hydraulic length = 0 ft Time of cons. (Tc) = 5.00 min Distribution = Type II Shape factor = 484 Post -Deg Drainage Area } Hyd. No 2 -- 25 Year 0 (cfs) 35.00 30.00 I 25.00 20.00 15.00 10.00 5.00 0.00 0.00 0 120 240 360 480 600 720 840 960 1080 1200 Time (min) Hyd No. 2 Hydraflow Rainfall Report Hydraflow Hydrographs Extension for AutoCAD® Civil 3D® 2014 by Autodesk, Inc. v10.3 Return Intensity -Duration -Frequency Equation Coefficients (FHA) Period - (Yrs) B D E (NIA) 1 -- 61.0947 12.4000 0.8835 2 68,5799 12.5000 0.8687 ---- -- 3 0.0000 0.0000 0.0000 - - - 5 73.4952 12.9000 0.8380 I -------- 10 74.1278 12.6000 0,8085 i 25 62,3903 11.0000 0.7384 50 57.3640 10A000 0,6975 -- 100 46.7062 7.0000 0.6561 File name: Westborough Freq.IDF Intensity = B / (Tc + D)AE Return Period (Yrs) 5 min 1 10 15 20 . 1� 1 4.90 3.92 3.28 2.83 2 5.71 4,59 3.85 3.33 3 0.00 0.00 0.00 0.00 5 6.55 5.33 4.52 3.93 10 7.30 5.96 5.07 4.43 25 8.05 6.59 5.63 4.94 50 8.64 7.07 6.06 5.34 100 9.15 7.28 6.15 5.37 Tc = time in minutes. Values may exceed 60. Sheetz at stb W 17� 8 Wednesday, 12 / 14 12016 Intensity Values (inlhr) 40 45 50 55 1.48 60 1.39 25 30 35 2.49 2.23 2.02 1.85 1.71 1.59 2.94 2.64 2.40 2.20 2.03 1.89 1.77 1.66 0.00 0.00 0.00 0.00 0.00 0,00 0.00 0.00 3.49 3.15 2.87 2.64 2.45 2.29 2,14 2.02 3.95 3.57 3.26 3.01 MO 2,62 2,46 2.32 4.43 4.02 3.69 3.42 3.19 3.00 2.83 2.68 4.80 4.37 4,03 3.74 3.50 3.30 3.12 2.96 4.81 4.37 4.02 3.74 3.50 3.29 3.11 2.96 _ nve (Sh_ eetz I nc.)120 T_ ech D ocs o-b[ormwater impact Anmysiswesworougn vrecip.pcp Rainfall Precipitation Table (in) Storm Distribution 1-yr 2-yr 3-yr 5-yr 10 yr 25-yr 50-yr 100-yr SCS 24-hour 2.84 3.42 0.00 0.00 4.96 5.87 0.00 7.32 SCS 6-Hr 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Huff -1st 0.00 0.00 0.00 0,00 0.00 0.00 0.00 0.00 Huff-2nd 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Huff-3rd 0.00 0.00 0.00 0.00 0,00 0.00 0.00 0,00 Huff-4th 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Huff-Indy 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Custom 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00