HomeMy WebLinkAboutNCG090006_MONITORING INFO_20161025M zv
STORMWATER DIVISION CODING SHEET
NCG PERMITS
PERMIT NO.
�V '�� d � 6 0 �
DOC TYPE
❑HISTORICAL FILE
MONITORING REPORTS
DOC DATE
❑ ok I Io I D a 5
YYYYMMDD
Semi-annual Stormwater Discharge Monitoring Report
for North Carolina Division of Water Quality General Permit No. NCG090000
Date submitted 10/19/16
11().bbbfp
CERTIFICATE OF COVERAGE NO. NCGO90000
FACILITY NAME Mallard Creek Polymers, Inc.
COUNTY Mecklenburg
PERSON COLLECTING SAMPLES Allan Oracion
LABORATORY Par Labs Lab Cert. # 20
Comments on sample collection or analysis:
Part A: Stormwater Benchmarks and Monitoring Results
SAMPLE COLLECTION YEAR 2016
SAMPLE PERIOD ❑ Jan -June ® July -Dec
or ❑ Monthly' month
DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA
V
RECEI� ED ❑Zero -flow ❑Water Supply ❑SA
®Other _C waterbody
OC.I 2 5 2016
CENTRALFILES PLEASE REMEMBER TO SIGN ON THE REVERSE 4
DWR SECTION
❑ No discharge this period?'
Outfall No.
Date Sample
1
Collected
(mo/dd/yr)
24-hour rainfall
amount,
Inches3
Total Cadmium
Total Chromium
Total Lead
Benchmarks =__>
-
-
0.001 mg/L
1.0 mg/L
0.03 mg/L
001
9/26/16
1.15
<0.001
< 0.005
<0.002
002
9/26/16
1.15
<0.001
<0.005
0.003
003
9/26/16
1.15
<0.001
<0.005
0.003
004
9/26/16
1.15
<0.001
<0.005
0.002
1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall.
z For sampling periods with no discharge at any single outfah, you must still submit this discharge monitoring report with a checkmark here.
3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement.
Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical
format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection
limit, reporting limit, etc. in mg/L.
Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 1, or Tier 3 responses. See General Permit text.
Permit Date: 11/1/2012-10/31/2017 5WU-255, last revised 10/25/2012
Page 1 of 2
Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month.
❑ No discharge this period:'
Outfall No.
Date Sample
Collected"
(mo/dd/yr)
24-hour rainfall
amount,
Inches3
Non -polar O&G/TPH by
EPA 1664 (SGT-HEM)
Total Suspended Solids
pH
Benchmarks =_=>
-
-
15 mg/L
100 mg/L or 50 mg/L*
6.0 — 9.0 SU
001
9/26/16
1.15
<5.6 mg/L
38 mg/L
6.32
002
9/26/26
1.15
<5.8 mg/L
25 mg/L
6.41
003
9/26/16
1.15
<6.0 mg/L
6 mg/L
6.49
004
9/26/16
1.15
<11.9 mg/L
44 mg/L
6.54
Footnotes from Part A also apply to this Part B
* See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies.
Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text.
FOR PART A AND PART B MONITORING RESULTS:
• A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B.
• 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS, SEE PERMIT PART II SECTION B.
• TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO
IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑
REGIONAL OFFICE CONTACT NAME:
Mail an oriainal and one copv of this DMR, includina all "No Discharae" reports, within 30 dovs of receipt of the lab results (or at end of monitorina period
in the case of "No Discharae" reports) to:
Division of Water Quality
Attn: DWQ Central Files
1617 Mail Service Center
Raleigh, North Carolina 27699-1617
YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED:
"I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to
assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or
those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete
am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations."
(Signature of Permittee)
10/19/2016
(Date)
Permit Date: 11/1/2012-10/31/2017 SWU-255, last revised 10/25/2012
Page 2 of 2
Semi-annual Stormwater Discharge Monitoring Report
for North Carolina Division of Water Quality General Permit No. NCG090000
Date submitted 10/19/16
CERTIFICATE OF COVERAGE NO. NCG090000 SAMPLE COLLECTION YEAR 2016
FACILITY NAME Mallard Creek Polymers, Inc. SAMPLE PERIOD ❑ Jan -June ® July -Dec
COUNTY Mecklenburg or ❑ Monthly'_ _(month
PERSON COLLECTING SAMPLES _ Allan Oracion DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA
LABORATORY Par Labs Lab Cert. # 20 ❑Zero -flow ❑Water Supply [:]SA
Comments on sample collection or analysis: ®Other_ C waterbody
Part A: Stormwater Benchmarks and Monitoring Results
PLEASE REMEMBER TO SIGN ON THE REVERSE -->
❑ No discharge this period?z
Outfall No.
pate Sample
Collected'
(mo/dd/yr)
24-hour rainfall
amount,
Inches3
Total Cadmium
Total Chromium
Total Lead
Benchmarks =__>
-
-
0.001 mg/L
1.0 mg/L
0.03 mg/L
001
9/26/16
2.15
<0.001
< 0.005
<0.002
002
9/26/16
1.15
<0.001
<0.005
0.003
003
9/26/16
1.15
<0.001
<0.005
0.003
004
9/26/16
1.15
<0.001
<0.005
0.002
1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall.
z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here.
3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement.
Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical
format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection
limit, reporting limit, etc. in mg/L.
Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text.
Permit Date: 11/1/2012-10/31/2017 SWU-255, last revised 10/25/2012
Page 1 of 2
Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month.
❑ No discharge this period?2
Outfall No.
Date Sample
Collected
(mo/dd/yr)
24-hour rainfall
amount,
Inches
Non -polar O&G/TPH by
EPA 1664 (SGT-HEM)
Total Suspended Solids
pH
Benchmarks =_=>
_
-
15 mg/L
100 mg/L or 50 mg/L*
6.0 — 9.0 SU
001
9/26/16
1.15
<5.6 mg/L
38 mg/L
6.32
002
9/26/16
1.15
<5.8 mg/L
25 mg/L
6.41
003
9/26/16
1.15
<6.0 mg/L
6 mg/L
6.49
004
9/26/16
1.15
<11.9 mg/L
44 mg/L
6.54
Footnotes from Part A also apply to this Part B
* See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies.
Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text.
FOR PART A AND PART B MONITORING RESULTS:
• A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B.
• 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART It SECTION B.
• TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO
IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑
REGIONAL OFFICE CONTACT NAME:
Mail an original and one copy of this DM& including all "No Discharge" reports, within 30 days of receipt of the lab results (or at end of monitoring period
in the case of "No Discharge" reports) to:
Division of Water Quality ^
Attn: DWQ Central Files
1617 Mail Service Center
Raleigh, North Carolina 27699-1617
YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED:
"I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to
assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or
those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete.
am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations."
(Signature of Permittee)
10/19/2016
(Date)
Permit Date: 11/1/2012-10/31/2017 SWU-255, last revised 10/25/2012
Page 2 of 2
PR OMP'T•ACCUR ATE• RELIABLE
LA130RA'CQRIES, INC
N%'WW.PAR1.AHS.00 ,%1
REPORT OF ANALYSES
Attn: ALLAN ORACION
MALLARD CREEK POLYMERS, INC.
2800 MOREHEAD RD.
CHARLOTTE, NC 28262-0499
RECEIVED
OCT 2 5 gals
CENTRAL FILES
DWR SECTION
PROJECT NAME: SEP 16
DATE: 10/18/16
SAMPLE NUMBER- 124979
SAMPLE' ID- MCP OU'_'PALL 1
SAMPLE MATRIX- WTN
DATE SAMPLED- 09/26/1.6
TIME SAMPLED- 0935
DATE RECEIVED- C9/26/16
SAMPLER- AO
RECEIVED BY- DJ
TIME RECEIVED- 1545
DELIVERED BY- AO
TYPE SAMPLE- Grab
Page 1 of 4
ANALYSIS
ANALYSIS
METHOD
DATE TIME BY RESULT UNITS
off VALUE
SM. 450OH-B
09/26/16 1550 DJ
6.32 units
OIL & GREASE
EPA 1664
09/30/16 1430 CT
< 5.6 mg/L
TOTAL SUSPENDED SOLIDS
SM 2540 D
-0/03/16 0755 DU
38 mg/L
CADMIUM, TOTAL
EPA 200.7
10/04/16 1153 CT <
0.001 mg/L
CHROMIUM, TOTAL
EPA 200.7
10/03/16 1205 CT <
0.005 mg/L
LEAD, TOTAL
EPA 200.7
10/04/16 0939 CT <
0.002 mg/L
LABORATORY
DI RECTO `r]�___�•• ���r
P.O. 11m 411483 • Charlotte, NC 28241-1483
Phone: (704) 588-8333 • F'a.r: (704) 588-8335
PAR
PROMPT -ACCURATE• RCt-lA FILE
LABORATORIES, INC
►► ►► ��.r.►kLARS,c.cV,t
REPORT OF ANALYSES
Attn: ALLAN Oi .AC I OFF
MALLARD CREEK POLYMERS, INC. PROJECT NAME: SEP 16
2800 MOREHEAD RD. DATE: 10/18/16
CHARLOTTE, NC 28262-0499
SAMPLE NUMBER- 124980
SAMPLE T_D- MCP OUT. -ALL 42
SAMPLE MATRIX- 4T,V
DATE SAMPLED- 09/26/16
TIME SAMPLED- 0940
DATE RECEIVED- 09/26/1.6
SAMPLER- AO
RECEIVED BY- DJ
TIME RECEIVED- 1545
DELIVERED BY- MO
TYPE SAMPLE- Grab
Page 2 of 4
ANALYSIS
ANAL'SIS
METHOD
DATE
TIME
BY
RESULT UNITS
pH VALUE
SM 450OH-3
09/26/16
1550
DJ
6.41 units
OIL & GREASE
EPA 1664
09/30/16
1430
CT
< 5.8 mg/L
TOTAL SUSPENDED SOLIDS
SM 2540 D
10/03/16
0755
DJ
25 mg/L
CADMIUM, TOTAL
EPA 200.7
10/04/16
1153
CT
< 0.001 mg/L
CHROMIUM, TOTAL
EPA 200.7
10/03/16
1205
CT
< 0.005 mg/L
LEAD, TOTAL
EPA 200.7
10/04/16
0939
CT
0.003 mg/L
LABORATORY DIRECTOR
P.O. Box 4114R3 • Charlotte, NC 28241-1483
Phone: (7041 588.8333 • Far: (704) 588-8335
A&
R
PRCim P7•ACCu PATE -RE LIABLE
LABORATORIES, INC
%V NV N'. PA R LA BS.0O3N l
REPORT 0= ANALYSES
Attn: ALLAN ORACION
MALLARD CREE_C POLYMERS, LNC. PROJECT NAME: SEP 16
2800 MOREHEAD RD. DATE: 10/18/16
CHARLOTTE, NC 28262-0499
SAMPLE NUMBER- 124981
SAMPLE ID- MCP OUT.ALL #3
SAMPLE MATRIX- WW
DATE SAMPLED- 09/26/LG
TIME SAMPLED- 0943
DATE RECEIVED- 09/26/16
SAMPLER- AO
RECEIVED BY- DJ
TIME RECEIVED- 1545
DELIVERED BY- AO
TYPE SAMPLE- Gram
Page 3 or 4
ANALYSIS
ANALYSIS
METHOD
DATE
TIME
BY
RESULT UNITS
pH VALUE
SM 450OH-3
09/26/16
1550
DJ
6.49 units
OIL & GREASE
EPA 1664
09/3C/1-6
1430
CT
< 6.0 mg/L
TOTAL SUSPENDED SOLIDS
SM 2540 D
10/03/16
0755
DJ
6 mg/L
CADMIUM, TOTAL
EPA 200.7
10/04/16
1153
CT
< 0.001 mg/L
CHROMIUM, TOTAL
EPA 200.7
10/03/16
1205
CT
< 0.005 mg/L
LEAD, TOTAL
EPA 200.7
10/04/16
0939
CT
0.003 mg/L
LABORATORY DIRECTOR
P.O. Box 411483 • Charlotte. NC 28241-1483
Phone: (704) 588-8333 • Fax: (704) 588-8335
PAR
PRO MPT• A CC U RATE -RELIABLE
LA130 RA"l'O R1 ES, INC
W WWAIL RLA I;S.C( )M
REPORT OF ANALYSES
Attn: ALLAN ORACION
MALLARD CREEK POLYMERS, !NC. PROJECT NAME: SEP 16
2300 MOREHEAD RD. DATE: 10/18/16
CHARLOTTE, NC 28262-0499
SAMPLE NUMBER- 124982
SAMPLE ID- MCP OUTPALL #4
SAMPLE MATRIX- WW
DATE SAMPLED- 09/26/16
TIME SAMPLED- 0945
DATE RECEIVED- 09/26/16
SAMPLER- AO
RECEIVED BY- DJ
TIME RECEIVED- 1545
DELIVERED BY- AO
TYPE SAMPLE- Grab
Page 4 of 4
ANALYSIS
ANALYSIS
METFOD
DATE
TIME
BY
RESULT UNITS
uH VALUE
SM 450OH-B
09/26/16
1550
DJ
6.54 units
OIL & GREASE
EPA 1664
09/30/16
1430
CT
< 11.9 mg/L
TOTAL SUSPENDED SOLIDS
SM 2540 D
10/03/16
0755
DJ
44 my/L
CADMIUM, TOTAL
EPA 200.7
10/04/16
1153
CT
< 0.001 mg/L
CHROMIUM, TOTAL
EPA 200.7
10/03/16
1205
CT
< 0.005 mg/L
LEAD, TOTAL
EPA 200.7
10/04/16
0939
CT
0.002 mg/L
LABORATORY DIRECTOR ,!
P.Q. Box 41 1483 • Charimte. NC 28241-1483
Phone: (7041588•8333 • Fax: (704) 589-8335
N.
0' mla�'301! I �
i
June 9, 2016
Division of Water Quality
Attn: DWQ Central Files
1617 Mail Service Center
Raleigh, NC 27699-1617
,FciEN ED
SUN 13 .106
CENTC ON
pWR S.-
Subject: Monitoring Results for
Mallard Creek Polymers, Inc.
Charlotte, Mecklenburg County, NC
General Permit No.: NCG090000
COC No.: NCG090006
Please find enclosed stormwater sampling results and the laboratory reports for
your files. Grab samples were performed at MCP Outfalls No. 0011002, 003 and
004. The stormwater event was analyzed by PAR Laboratories, North Carolina
certification no. 20.
There was 1 TSS sampling result that was above benchmark value requiring a
Tier one response action. All other results were below benchmark values.
Please call me at {704}547-0622, ext. 1009, if you have any comments or
questions on this data submittal.
Sincerely,
Allan Oracion
Compliance Manager
Mallard Creek Polymers, Inc.
Mallard Creek Polymers, Inc. 2800 Morehead Road, Charlotte, NC 28262-0499 704-547-0622
Semi-annual Stormwater Discharge Monitoring Report
for North Carolina Division of Water Quality General Permit No. NCG090000
Date submitted _ 6/6/16
CERTIFICATE OF COVERAGE NO. NCG090000 7 U 0 (]- 6
FACILITY NAME Mallard Creek Polymers. Inc.
COUNTY Mecklenburg _
PERSON COLLECTING SAMPLES Allan Oracion
LABORATORY Par Labs Lab Cert. # 20
Comments on sample collection or analysis:
Part A: Stormwater Benchmarks and Monitoring Results
SAMPLE COLLECTION YEAR 2016
SAMPLE PERIOD ® Jan -June ❑ July -Dec
pp r�--++ or ❑ Monthly' (month'
RECER96MRGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA
JUN 1 3 2A ❑Zero -flow ❑Water Supply ❑SA
®Other C waterbod
CENTRAL FILES
DWR SECTION PLEASE REMEMBER TO SIGN ON THE REVERSE
❑ No discharge this period?z
Outfall No.
Date.Sample
Collected
(mo/dd/yr)
24-hour rainfall
amount, -
Inches3
Total Cadmium
Total Chromium .:
Total Lead
Benchmarks
0.001 mg/L
1.0 mg/L
0.03 mg/L
001/002
5/17/16
.83
<0.001
< 0.005
<0.002
003
5/17/16
.83
<0.001
<0.005
<0.002
004
5/17/16
.83
<0.001
<0.005
0.002
1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfali.
z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here.
3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement.
Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical
format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection
limit, reporting limit, etc. in mg/L.
Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text.
Permit Date: 11/1/2012-10/31/2017 SWU-255, last revised 10/25/2012
Page 1 of 2
Pa&B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month.
❑ No discharge this period?'
Oytfall No.
Date Sample
Collected
(mo/dd/yr)
24-hour rainfall: .
amount,,
Inches
Non -polar 0&G/TPH by
EPA 1664 (SGT�.HEM)
Total'Suspended Solids
pH
Benchmarks ===i
_
15 mg/L ,
% 100 mg/L or 50 mg/L*
6.0 - 9..0 SU
001/002
5/17/16
.83
<6.1 mg/L
11 mg/L
6.64
003
5/17/16
.83
<9.8 mg/L
49 mg/L
6.54
004
5/17/16
.83
<9.1 mg/L
172 mg/L
6.13
Footnotes from Part A also apply to this Part B
* See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies.
Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text.
FOR PART A AND PART B MONITORING RESULTS:
• A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B.
• 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B.
• TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO
IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑
REGIONAL OFFICE CONTACT NAME:
Mail an oriainal and one coov of this DMR, includina all "No Discharae" reports, within 30 dovs of receipt of the lob results for at end of monitoring period
in the case of "No Discharge" reports) to:
Division of Water Quality
Attn: DWQ Central Files
1617 Mail Service Center
Raleigh, North Carolina 27699-1617
YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED:
"I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to
assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or
those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete.
am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations."
(Signature of Permittee)
6/9/2016
(Date)
Permit Date:11/1/2012-10/31/2017
SWU-255, last revised 10/25/2012
Page 2 of 2
Epumm
4�
PRp'+1f-�7•t.L:CIJFTAY�• i"iCLlA9L.ii
INC
REPORT OF ANALYSES
Attn: ALLAN ORACION
14ALLARD CREEK POLYMERS, INC.
2800 MOREHEA€D R€}.
CHARLOTTE, NC 28262-0499
PROJECT NAME: MAY 16
[SATE: 06/06/16
RECEIVED
JUN 13 2U16
CENTRAL FILES
DWR SECTION
SAMPLE NUMBER- 123383
SAMPLE ID- OUTFALL 0-1
SAMPLE MATRIX- WO
DATE SAI++iPLED- 05/17/16
TINE SAMPLED- 0915
DATE RECEIVED- 05/17/16
SAMPLER- AO
RECEIVED BY- RE
TIME RECEIVED- 1630
DELIVERED BY- AO
TYPE SAMPLE- Grab
Page 1 of 3
ANALYSIS
ANALYSIS
METHOD
DATE
TIME
BY
RESULT UNITS
pH VALUE
SM450OH-B
05/17/16
1645
RE
6.64 units
OIL & GREASE
EPA 1664
05/24/16
1050
CT.
< 6.1 mg/L
TOTAL SUSPENDED SOLIDS
SM 2540 D
05/23/16
0810
DJ
11 mg/L
CADMIUM, TOTAL
EPA 200.7
05/25/16
1419
CT
< 0.001 mg/L
CHROMIUM, TOTAL
EPA 200.7
DS/25/16
1028
CT
< 0.005 mg/L
LEAD, TOTAL
EPA 200.7
05/27/16
0957
CT
< 0.002 mg/L
LABORATORY DIRECTOR
P. CB. Box •111A� I C • harloac, NC 2,9241-14S3
i�ltr�nr� (i(1�i a-3,,�3 • €":��: {7(1�) SfiS-923�
d .,.
Bono
W ie'^`$F F•A£.'C., iS 42ATG•fi �i..l ACi ie �'
PA
L ,e%-BC7}2A"['OIt!F--S.T INC
11'N% W.PARLAf3S.t:t)4!
REPORT OF ANALYSES
Attn: ALLAN ORACION
MALLARD CREEK POLYMERS, INC. PROJECT NAME: MAY 16
2800 MOREHEAD RD. DATE: 06/06/16
CHARLOTTE, NC 28262-0499
SAMPLE NUMBER-
123384
SAMPLE ID- OUTFRLL 0-3
SAMPLE MATRIX- WW
DATE SAMPLED-
05/17/16
TIME SAMPLED- 0920
DATE RECEIVED-
05/17/16
SAMPLER- AO
RECEIVED BY- RE
TIME RECEIVED-
1630
DELIVERED BY- AO
TYPE SAMPLE- Grab
Page 2 4f 3
ANALYSIS
ANALYSIS
METHOD DATE TIME BY
RESULT UNITS
pH VALUE
OIL & GREASE
TOTAL SUSPENDED SOLIDS
CADMIUM, TOTAL
CHROMIUM, TOTAL
LEAD, TOTAL
SM450OH-B
EPA 1664 05/24/16 1050 CT
SM 2540 D 05/23/16 0810 DJ
EPA 200.7 05/25/16 1419 CT
EPA 200.7 05/25/16 1028 CT
.EPA 200.7 05/27/16 0957 CT
LABORATORY DIRECTOR
11.0. Hnx 41148 �"h:irlwtc. NC 28241.1»S3
Phony' t 7(1.3) -SS-K333 • Fnv (?04) SCR-R 315
05/17/16 1645 RE 6.54 unit
< 9.8 mg/L
49 mg/L
< 0.001 mg/L
< 0.005 mg/L
< 0.002 mg/L
m
R
�F2"twat6yy'•�aCCiJs7AT�•F?L.x_ix•L�L.Y'
LA140RATC3i2IES;, INC-
i1'W11.}'.%RI .1E45.f'(3 LI
REPORT OF ANALYSES
Attn: ALLAAN ORACION
MALLARD CREEK POLYMERS, INC. PROJECT NAME: MAY 16
2800 MOREHEAD RD. DATE: 06/06/16
CHARLOTTE, NC 28262-0499
SAMPLE NUMBER- 123385 SAMPLE ID- OUTFALL 0-4
DATE SAMPLED- 05/17/16
DATE RECEIVED- 05/17/16 SAMPLER- AO
TIME RECEIVED- 1630 DELIVERED BY- AO
Page 3 of 3
SAMPLE MATRIX- ;�Aq
TIME SAI'4PLED- 0920
RECEIVED BY- RE
TYPE SAMPLE.- Grab
ANALYSIS
ANALYSIS
METHOD
DATE
TIME
BY
RESULT
UNITS
pH VALUE
SM450OH-3
05/17/16
1645
RE
6.13
units
OIL & GREASE.
EPA 1664
05/24/16
1050
CT
< 9.1
mg/L
TOTAL SUSPENDED SOLIDS
SM 2540 D
05/23/16
0810
DJ
172
mg/L
CADMIUM, TOTAL
EPA 200.7
05/25/16
1419
CT
< 0.001
mg/L
CHROMIUM, TOTAL
EPA 200.7
05/25/16
1028
CT
< 0.005
mg/L
LEAD, TOTAL
EPA 200.7
05/27/16
0957
CT
0.002
mg/L
LABORATORY DIRECTOR
RO (3a !; • Chas3otte. C ?�?? #� 1483
Ptione: (04) VS-W3 • hsx: (+Oki)538-8335
PROMPT•ACCURATE-RELIABLE
LABORATORIES, INC
NNAN'11'. PAR LA BS.CO N1
�,cG-oq 000�O
REPORT OF ANALYSFS
Attn: ALLAN ORACION
MALLARD CREEK POLYMERS, INC. PROJECT NAME: DEC 14
2800 MOREHEAD RD. DATE: 12/31/14
CHARLOTTE, NC 28262-0499
SAMPLE NUMBER-
117175
SAMPLE TD- MCP OUTFALL #1
SAMPLE MATRIX- WW
SAMrLh;ll- i
2! 24% 1 4
TIME SAMPLED- 0830
DATE RECEIVED-
12/24/14
SAMPLER- AO
RECEIVED 3Y- RE
TIME RECEIVED-
1122
DELIVERED BY- AO
TYPE SAMPLE- Gran
Page 1 of 3
ANALYSIS
ANALYSIS
METHOD
DATE
TIME
BY
RESULT UNITS
PH VALUE
SM 450OH-B
12/24/14
0830
AO
6.7 units
OIL & GREASE
EPA 1664
12/29/14
1330
CT
5 mg/L
TOTAL SUSPENDED
SOLIDS
SM 2540 D
12/29/14
0910
DJ
15 mg/L
CADMIUM, TOTAL
EPA 200.7
12/30/14
1157
CT
< 0.002 mg/L
CHROMIUM, TOTAL
EPA 200.7
12/30/14
1157
CT
0.006 mg/I,
LEAD, TOTAL
EPA 200.7
12/20/14
1157
CT
0.002 mg/L
LABORATORY DIRECTOR >r ��-
11.0. Box 411483 • Charlotte, NC 28241-1483
Plume: (704) 598-8333 • Fax: (704) 588-8335
'PAR
PRCMPT•ACCURATE• RELIABLE
LA.BORATORIES, INC
NVWW.PAH1ABS.CONI
REPORT OF ANALYSES
Attn: ALLAN ORACION
MALLARD CREEK POLYMERS, INC. PROJECT NAME: DEC 14
2800 MOREHEAD RD. DATE: 12/31/14
CHARLOTTE, NC 28262-0499
SAMPLE NUMBER- 117176
SAMPLE ID- MCP OUTFALL #2
SAMPLE MATRIX- WW
DATE SAMPLED- 12/24/14
TIME SAMPLED- 0820
DATE RECEIVED- 12/24/14
SAMPLER- AO
RECEIVED BY- RE
TIME RECEIVED- 1122
DELIVERED BY- AO
TYPE SAMPLE- Grab
Page 2 of 3
ANALYSIS
ANALYSIS
METHOD
DATE
TIME
BY
RESULT UNITS
pE VALUE
SM 450OH-3
12/24/14
0820
AO
6.8 units
OIL & GREASE
EPA 1664
12/29/14
1330
CT
< 5 mg/L
TOTAL SUSPENDED SOLIDS
SM 2340 D
12/29/14
0910
DJ
6 mg/L
CADMIUM, TOTAL
EPA 200.7
12/30/14
1157
CT
< 0.002 mg/L
CHROMIUM, TOTAL
EPA 200.7
12/30/14
1157
CT
0.006 mg/L
LEAD, TOTAL
EPA 200.7
12/30/14
1157
CT
< 0.002 mg/L
LABORATORY DIRECTOR
P.O. Box 411493 • Charlotte, NC 28241-1483
111mic: (704) 588-9333 • Far: (704) 588-8335
a
p ANK
PPOMPT•ACCUPATE• RELiAULE
LABORATORIES, INC
NVNXINN'.PA RLA IIS.COINI
REPORT OF ANALYSES
Attn: ALLAN ORACION
MALLARD CREEK POLYMERS, INC. PROJECT NAME: DEC 14
2800 MOREHEAD RD. DATE: 12/31/14
CHARLOTTE, NC 28262-0499
SAMPLE NUMBER- 117177 SAMPLE ID- MCP OUTFALL 43
DATE SAMPLED- 12/24/14
DATE RECEIVED- 12/24/14 SAMPLER- AO
TIME RECEIVED- 1122 DELIVERED BY- AO
Page 3 of 3
SAMPLE MATRIX- WW
TIME SAMPLED- 0815
RECEIVED BY- RE
TYPE SAMPLE- Grab
ANALYSIS
ANALYSIS
METHOD
DATE
TIME
BY
RESULT
UNITS
pH VALUE
SM 4500H-B
12/24/14
0815
AO
6.5
units
OIL & GREASE
EPA 1664
12/29/14
1330
CT
9
mg/L
TOTAL SUSPENDED SOLIDS
SM 2540 0
12/29/14
0910
DJ
< 5
mg/L
CADMIUM, TOTAL
EPA 200.7
12/30/14
1157
CT
< 0.002
mg/L
CHROMIUM, TOTAL
EPA 200.7
12/30/14
1157
CT
< 0.005
mg/L
LEAD, TOTAL
EPA 200.7
12/30/14
1157
CT
< 0.002
mg/L
LABORATORY DIRECTOR
P.O. Box 411483 • Charlotte, NC 28241-1483
Phone: (704) 588-8333 • Fax: (704) 588-R335
(&MCP
Mallard Creek
Po ymers
January 7, 2015
Division of Water Quality
Attn: DWQ Central Files
1617 Mail Service Center
Raleigh, NC 27699-1617
Subject: Monitoring Results for
Mallard Creek Polymers, Inc.
Charlotte, Mecklenburg County, NC
General Permit No.: NCGO90000
COC No.: NCGO90006
Please find enclosed stormwater sampling results and the laboratory reports for
your files. Grab samples were performed at MCP Outfalls No. 001, 002 and 003.
The stormwater event was analyzed by PAR Laboratories, North Carolina
certification no. 20.
Please note: Cadmium analysis for all three outfalls was below detection limit;
however the benchmark for cadmium is below PAR Laboratories detection limit.
Please call me at (704)547-0622, ext. 1009, if you have any comments or
questions on this data submittal.
Sincerely,
Allan Oracion
Compliance Manager
rJ0
Mallard Creek Polymers, Inc.
z
n
M
m-
z
�..
0
M
zgym„
M
0
s
Mallard Creek Polymers, Inc. 2800 Morehead Road, Charlotte, NC 28262-0499 704-547-0622
Semi-annual Stormwater Discharge Monitoring Report
for North Carolina Division of Water Quality General Permit No. NCG090000
Date submitted 1/7/15
CERTIFICATE OF COVERAGE NO. N00090000 Y)C.6O [ O X
FACILITY NAME Mallard Creek Polymers, Inc.
COUNTY Mecklenbure
PERSON COLLECTING SAMPLES Allan Oracion
LABORATORY Par Labs Lab Cert. #
Comments on sample collection or analysis:
O
Part A: Stormwater Benchmarks and Monitoring Results
SAMPLE COLLECTION YEAR 2014
SAMPLE PERIOD ❑ Jan -June ® July -Dec
or ❑ Monthly)_ T (month)
DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA
❑Zero -flow ❑Water supply ❑SA
®Other C waterbody
PLEASE REMEMBER TO SIGN ON THE REVERSE 4
❑ No discharge this period?z
Outfall Na.
Date Sample
Collected'
(mo/dd/yr)
24-hour rainfall
amount,
lnches3
Total Cadmium
Total Chromium
Total Lead
Benchmarks =_->
0.001 mg/L
1.0 mg/L
0,03 mg/L
001
04/07/14
<0.002
<0.006
0.002
002
04/07/14
<0.002
0.006
<0.002
003
04/07/14
<0.002
<0.005
<0.002
1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall.
z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here.
3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement.
Note: Results must be reported in numerical format. Do not report Below Detection Limit, 3DL, <PQL, Non -detect, ND, or other similar non -numerical
format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection
limit, reporting limit, etc. in mg/L.
Note: If you report o sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text.
Permit Date: 11/1/2012-10/31/2017 SWU-255, last revised 10/25/2012
Page 1 of 2
Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month.
❑ No discharge this period?z
Outfall No.
Date Sample
Collected'
(mo/dd/yr)
24-hour rainfall
amount,
Inches3
Non -polar O&G/TPH by
EPA 1664 (SGT-HEM)
Total Suspended Solids
pH
Benchmarks =_=>
-
15 mg/L
100 mg/L or 50 mg/L*
6.0 — 9.0 SU
001
12/24/14
5 mg/L
15 mg/L
6.7
002
12/24/14
<5 mg/L
6 mg/L
6.8
003
12/24/14
9 mg/L
<5 mg/L
6.5
Footnotes from Part A also apply to this Part B
* see General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies.
Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text.
FOR PARTA AND PART B MONITORING RESULTS:
• A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS, SEE PERMIT PART II SECTION B.
• 2 EXCEEDANCFS IN A ROW FOR THE SAME PARAMETER ATTHE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART I€ SECTION B.
• TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDFNCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES ❑ NO.®
IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑
REGIONAL OFFICE CONTACT NAME:
Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results (or at end of monitoring period
in the case o "No Dischar e" reports) to:
Division of Water Quality
Attn: DWQ Central Files
1617 Mail Service Center
Raleigh, North Carolina 27699-1617
YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED:
"I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to
assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or
those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I
am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations."
(.Signature of Permittee)
1/7/2015
(Date)
Permit Date:11/1/2012-10/31/2017
SWU-255, last revised 10/25/2012
Page 2 of 2
Semi-annual Stormwater Discharge Monitoring Report
for North Carolina Division of Water Quality General Permit No. NCG090000
Date submitted 5/1/14
CERTIFICATE OF COVERAGE NO. NCG09000O Nck q
DO V SAMPLE COLLECTION YEAR 2014
FACILITY NAME Mallard Creek Polymers, Inc. SAMPLE PERIOD ® Jan -June ❑ July -Dec
COUNTY Mecklenburg or ❑ Monthly' (month)
PERSON COLLECTING SAMPLESAllan Oracion DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA
LABORATORY Par Labs Lab Cert. t# 20 RECEIVE® ❑Zero -flow ❑Water Supply []SA
Comments on sample collection or analysis: ®Other C waterbody
MAY 12 2414
>✓ENTRA1 1=1LES PLEASE REMEMBER TO SIGN ON THE REVERSE 4
Part A: Stormwater Benchmarks and Monitoring Results DWQIBOG
❑ No discharge this period?
Outfall No.
Date Sample
Collected
(mo/dd/yr)
24-hour rainfall
amount,
Inches3
Total Cadmium
Total Chromium
Total Lead
Benchmarks ===>
-
-
0.001 mg/L
1.0 mg/L
0.03 mg/L
001
04/07/14
<0.002
<0.005
<0.002
002
04/07/14
<0.002
<0.005
<0.002
003
04/07/14
<0.002
<0.005
<0.002
1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall.
2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here.
3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement.
Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical
format. When results are below the applicable limits, they must be reported in the format, "<XX mgjC, where XX is the numerical value of the detection
limit, reporting limit, etc. in mg/L.
Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text.
Permit Date: 11/1/2012-10/31/2017 SWU-255, last revised 10/25/2012
Page 1 of 2
• � _ r. � - ,
.. .. � �
'C � .. �
t
.. � i - ' ..
�r �
Part B. Vehicle Maintenance Area Monitoring Results: only for facilities averaging > S5 gal of new oil per month.
❑ No discharge this period ?2
Outfall Na.
Date Sample
Collected'
(mo/dd/yr)
24-hour rainfall
amount,
Inches3
Non -polar O&G/TPH by
EPA 1664 (SGT-HEM)
Total Suspended Solids
pH
Benchmarks =__>
-
-
15 mg/L
100 mg/L or 50 mg/L*
6.0 — 9.0 SU
001
04/07/14
16 mg/L
64 mg/L
7.1
002
04/07/14
<5 mg/L
16 mg/L
6.8
003
04/07/14
15 mg/L
7 mg/L
6.6
Footnotes from Part A also apply to this Part B
* See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies.
Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text.
FOR PART A AND PART B MONITORING RESULTS:
• A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B.
• 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART Il SECTION B.
• TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO
IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑
REGIONAL OFFICE CONTACT NAME:
Mail an oriainal_and one co py—o this DMA, includi� all "No Discharge" reports, within 30 days of receipt of the lab results for at end of monitoring period
in the case of "No Discharae" reports) to:
Division of Water Quality
Attn: DWQ Central Files
1617 Mail Service Center
Raleigh, North Carolina 27699-1617
YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED:
"I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to
assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or
those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I
am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations."
(Signature of Permittee)
Permit Date:11/1/2012-10/31/2017
5/1/2014
(Date)
SWU-255, last revised 10/25/2012
Page 2 of 2
PA
PRC7MP7•ACCuLZATE• RELAE3LE
I,ABORATORI.ES, INC
NNAN'W iPkR[.ARS.COM
REPORT OF ANALYSES
At Lii: ALLAN ORACION
MALLARD CREEK POLYMERS, INC. PROJECT NAME: APR 14
2800 MOREHEAD RD. DATE: 04/15/14
CHARLOTTE, NC 28262-0499
SAMPLE NUMBER- 113426 SAM.PLF D- MCP P1 OUmEA?..I,
DATE SAMPLED- 04/07/14
DATE RECEIVED- 04/07/14 SAMPLER- AO
TIME RECEIVED- 1644 DELIVERED BY- AO
Page 1 of 3
SAMPLE MATRIX- WW
TIME SAMPLED- 0825
RECEIVED BY- RE
TYPE SAMPLE- Grab
ANALYSTS
ANALYSTS
METHOD
DATE
TIME
BY
RESULT
UNITS
pH VALUE
SM 450CH-B
04/07/14
0825
AC
7.1
uniLs
OIL & GREASE
EPA 1664
04/11/14
1600
CN
16
mg/L
TOTAL SUSPENDED SOLIDS
SM 2540 D
04/14/14
0810
DJ
64
mg/L
CADMIUM, TOTAL
EPA 200.7
04/15/14
1003
CT
< 0.002
mg/L
CHROMIUM, TOTAL
EPA 200.7
04/15/14
1003
CT
< 0.005
mg/L
LEAD, TOTAL
EPA 200.7
04/15/14
1003
CT
< 0,002
mg/L
LABORATORY DIRECTOR
P.O. Box 411483 • Charlotte, NC 28241-1483
I'lhone: (704) 588-83 33 • Fa.v (704) 598-8335
PROM PT•ACCUPATr. REt_SAOLC
.LAB ORATORI.ES, INC
\1'\1'N'.PAR1 ABS.CU\f
REPORT OF ANALYSES
Attn: ALLAN ORACION
MALLARD CREEK POLYMERS, INC. PROJECT NAME: APR 14
2800 MOREHEAD RD. DATE: 04/15/14
CHARLOTTE, NC 28262-0499
SAMPLE NUMBER- 113427 SAMPLE ID- MCP #2 OUTFALL
DATE SAMPLED- 04/07/14
DATE RECEIVED- 04/07/14 SAMPLER- AO
TIME RECEIVED- 1644 DELIVERED BY- AO
Page 2 of 3
ANALYSIS
off VALUE
OLL & GREASE
TOTAL SUSPENDED SOLIDS
CADMIUM, TOTAL
CHROMIUM, TOTAL
LEAD, TOTAL
SAMPLE MATRIX- ww
TIME SAMPLED- 0822
RECEIVED BY- RE
TYPE SAMPLE- Grab
ANALYSIS
MET130D DATE TIME BY RESULT UNITS
SM
450OH-B
04/07/14
0822
AO
6.8
units
EPA
1664
04/11/14
1600
CN
< 5
mg/L
SM
2540 D
04/14/14
0810
Di
16
mg/L
EPA
200-7
04/15/14
1003
CT
< 0.002
mg/L
EPA
200.7
04/15/14
1003
CT
< 0.005
mg/L
EPA
200.7
04/15/14
1003
CT
< 0.002
mg/L
1112
LABORATORY DIRECTOR '
P.O. 13ox 411483 • Charlotte, N'C 28241-1483
Phone: (704) 588-8333 • Fas: (704) 588-8335
P�
nR
PROM PT•ACCLIRATE• RELIAIBLE
LABORATORIES, INC
1YM N'.PARLABS.00\!
REPORT OF ANALYSES
Attn: ALLAN ORACION
MALLARD CREEK POLYMERS, INC. PROJECT NAME: APR 14
2800 MOREHEAD RD, DATE: 04/15/14
CHARLOTTE, NC 28262-0499
SAMPLE NUMBER- 113428 SAMPLE ID- MCP #3 OUTFALL
DATE SAMPLED- 04/07/14
DATE RECEIVED- 04/07/14 SAMPLER- AO
TIME RECEIVED- 1644 DELIVERED BY- AO
Page 3 of 3
SAMPLE MATRIX- WW
TIME SAMPLED- 0820
RECEIVED BY- RE
TYPE SAMPLE- Grab
ANALYSIS
ANALYSIS
METHOD
DATE
TIME
BY
RESULT
UNITS
DH VALUE
SM 450OH-B
04/07/14
0820
AO
6.6
units
OIL & GREASE
EPA 1664
04/11/14
1600
CN
15
mg/L
TOTAL SUSPENDED SOLIDS
SM 2540 D
04/14/14
0810
DJ
7
mg/L
CADMIUM, TOTAL
EPA 200.7
04/15/14
1003
CT
< 0.002
mg/L
CHROMIUM, TOTAL
EPA 200.7
04/15/14
1003
CT
< 0.005
mg/L
LBAD, TOTAL
EPA 200.7
04/15/14
1003
CT
< 0.002
mg/L
LABORATORY DIRECTOR
P.O. Box 411483 • Chm'lnuc. NC 29241-1483
Phonc: (704) 588-8333 • FaLV (704) 588-8335
(& MCP
y Polmers
May 8, 2014
Division of Water Quality
Attn: DWQ Central Files
1617 Mail Service Center
Raleigh, NC 27699-1617
Subject: Monitoring Results for
Mallard Creek Polymers, Inc.
Charlotte, Mecklenburg County, NC_
General Permit No.: NCG090000
COC No.: NCG090006
Please find enclosed stormwater sampling results and the laboratory reports for
your files. Grab samples were performed at MCP Outfalls No. 001, 002 and 003,
The stormwater event was analyzed by PAR Laboratories, North Carolina
certification no. 20.
Please note: Cadmium analysis for all three outfalls was below detection limit;
however the benchmark for cadmium is below PAR Laboratories detection limit.
Please call me at (704)547-0622, ext. 1009, if you have any comments or
questions on this data submittal.
Sincerely,
Allan Oracion
Compliance Manager
Mallard Creek Polymers, Inc.
Mallard Creek Polymers, Inc. 14700 Mallard Creek Road, Charlotte, NC 28262-0499 704-547-0622