Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NCG080893_MONITORING INFO_20190206
STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. /V '�� U �U � �> DOC TYPE El HISTORICAL FILE {y MONITORING REPORTS DOC DATE YYYYMMDD Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Energy, Mineral and Land Resources General Permit No. NCG080000 CERTIFICATE OF COVERAGE No. NCG08 0 8 9 3 FACILITY NAME Greensboro Transit Authority COUNTY Guilford PERSON COLLECTING SAMPLES rorien R. Deaton LABORATORY Pace Analytical Lab Cert. # 12 Comments on sample collection or analysis: Date submitted 2/4/2020 SAMPLE COLLECTION YEAR 2020 SAMPLE PERIOD ❑■ Jan -June ❑ July -Dec © or ❑ Monthly' (month) 1' ECFJ�/Pi j IARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow *WaterSupply [:]SA FEB U 6 2019 ❑Other CCIS r .' ry ILES PLEASE REMEMBER TO SIGN ON THE REVERSE 4 DWR SECTION Did this facility perform Vehicle Maintenance Activities using more than 55 gallons of new oil per month? ■❑ yes ❑ no (if yes, complete Part A) Part A: Vehicle & Equipment Maintenance Areas Monitoring Requirements (If applicable) ❑ No discharge this period' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches' Non -Polar Oil & Grease mg/L Total Suspended Solids, mg/L New Motor or Hydraulic Oil Usage, gal/man Benchmarks _ - 15 100 or 504 Parameter Code - 46529 00552 C0530 NCOIL SDO-001 1/24/2020 1.27 <5.0 5.0 350 SDO-002 1/24/2020 1.27 <4.8 6.4 350 SDO-003 1/24/2020 1.27 <5.0 <5.0 350 SD O-004 1 /24/2020 1.27 <5.0 2.5 350 ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. Z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 'The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit text, Table 1, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Note: Results must be reported in numerical format. For example, do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non - numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Conversely, where fecal coliform results exceed the dilution upper limit, report the result as ">XX". Permit Date: 11/1/2018-5/31/2021 SWU-248, last revised 11/1/2018 Page 1 of 2 Part 13: Oil/water Separators and Secondary Containment Areas at Petroleum Bulk Stations and Terminals (if applicable) ❑ No discharge this period' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches' Sample Collected' mo/dd/yr Total Suspended Solids, mg/L pH, Standard units -Non-Polar Oil & Grease, mg/L Permit -Limit - - 100 or 50' 6.0 — 9.0 15 Parameter Code - 46529 C0530 00400 00552 Footnotes from Part A also apply to this Part B Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: + A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. + 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO IF YES, HAVE YOU CONTACTED THE DEMLR REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Brandon wise Mail an oriainal copv of this DMR. includina all "No Discharge" reports, within 30 days of receipt of the lab results (or at end of monitorina period in the case o "No Dischar e" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted.' Based an my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." Signature of Permittee Date Permit Date. 11/1/2018-5/31/2021 SWU-248, last revised 11/1/2018 Page 2 of 2 aceAnalytfical e www.pacetabs.com January 29, 2020 Richard P Lovett City of Greensboro Field Operations Department 401 Patton Ave Greensboro, NC 27406 RE: Project: GTA Pace Project No.: 92462213 Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Dear Richard Lovett: Enclosed are the analytical results for sample(s) received by the laboratory on January 24, 2020. The results relate only to the samples included in this report. Results reported herein conform to the most current, applicable TNIINELAC standards and the laboratory's Quality Assurance Manual, where applicable, unless otherwise noted in the body of the report. If you have any questions concerning this report, please feel free to contact me. Sincerely, VC -A. -011�K5--2 Amanda Payne amanda.payne@pacelabs.com (704)875-9092 Project Manager Enclosures cc: Lorien Koontz, City of Greensboro Field Operations Department Anna Stoddard, City of Greensboro Field Operations Department 7NI' l�BDRA�� REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except In full, without the written consent of Pace Analyfical Services, LLC. Page 1 of 13 aceAnalytfical www,pacel abs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 CERTIFICATIONS Project: GTA Pace Project No.: 92462213 Pace Analytical Services Charlotte 9800 Kincey Ave. Ste 100, Huntersville, NC 28078 South Carolina Certification #: 99006001 LouisianalNELAP Certification # LA170028 Florida/NELAP Certification #: EB7627 North Carolina Drinking Water Certification #: 37706 Kentucky UST Certification #: 84 North Carolina Field Services Certification #: 5342 Virginia/VELAP Certification #: 460221 North Carolina Wastewater Certification #: 12 Pace Analytical Services Asheville 2225 Riverside Drive, Asheville, NC 28804 Florida/NELAP Certification #: E87648 Massachusetts Certification #: M-NC030 North Carolina Drinking Water Certification #: 37712 North Carolina Wastewater Certification #: 40 South Carolina Certification #: 99030001 Virginia/VELAP Certification #: 460222 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 2 of 13 aceAnalytrcal www.Pat:elabs.com SAMPLE ANALYTE COUNT Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Project: Pace Project No.: GTA 92462213 Analytes Lab ID Sample ID Method Analysts Reported Laboratory 92462213001 SDO-001 EPA 16646 HH 1 PASI-C SM 254OD-2011 CJL 1 PASI-A 92462213002 SDO-002 EPA 1664B HH 1 PASI-C SM 254OD-2011 CJL 1 PASI-A 92462213003 SDO-003 EPA 1664B HH 1 PASI-C SM 254OD-2011 CJL 1 PASI-A 92462213004 SDO-004 EPA 16648 HH 1 PASI-C SM 254OD-2011 CJL 1 PASI-A REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 3 of 13 aceAnalXical www,pacelabs.com ANALYTICAL RESULTS Project: GTA Pace Project No.: 92462213 Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Sample: SDO-001 Lab ID: 92462213001 Collected: 01/24/20 08:05 Received: 01/24/20 10:28 Matrix: Water Parameters Results Units Report Limit OF Prepared Analyzed CAS No. Qual HEM, Oil and Grease Analytical Method: EPA 1664B Oil and Grease ND mg/L 5.0 1 01/28/20 16:45 2540D Total Suspended Solids Analytical Method: SM 254OD-2011 Total Suspended Solids 5.0 mglt- 5.0 1 01/28/20 17:35 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 01129/2020 03:45 PM without the written consent of Pace Analytical Services, LLC. Page 4 of 13 Pace Analytical Services, LLC a 9800 Kinsey Ave, Suite 100 aceAnalytical Huntersville, NC 28078 www. pacelabs.cam (744)87 59092 ANALYTICAL RESULTS Project: GTA Pace Project No.: 92452213 Sample: SDO-002 Lab ID: 92462213002 Collected: 01124120 08:20 Received: 01/24/20 10:28 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual HEM, Oil and Grease Analytical Method: EPA 1664B Oil and Grease ND mg1L 4.8 1 01/28/20 17:06 2540D Total Suspended Solids Analytical Method: SM 2540D-2011 Total Suspended Solids 6.4 mg1L 5.0 1 01/28120 17:35 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 01/29/2020 03:45 PM without the written consent of Pace Analytical Services, LLC. Page 5 of 13 aceAnalj6cal www.pacelabs.com ANALYTICAL RESULTS Project: GTA Pace Project No.: 92462213 Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersviile, NC 28078 (704)875-9092 Sample: SDO-003 Lab ID: 92462213003 Collected: 01/24/20 08:30 Received; 01/24/20 10:28 Matrix; Water Parameters Results units Report Limit DF Prepared Analyzed CAS No. Qual HEM, Oil and Grease Analytical Method: EPA 1664B Oil and Grease ND mg1L 5.0 1 01/28/20 16:46 2540D Total Suspended Solids Analytical Method: SM 254OD-2011 Totat Suspended Solids ND mg1L 5.0 1 01/28120 17:35 Date: 01/29/2020 03A5 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC, Page 6 of 13 aceAnalytical www.pacelabs.corn ANALYTICAL RESULTS Pate Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)87 59092 Project: GTA Pace Project No.: 92462213 Sample: SDO-004 Lab ID: 92462213004 Collected: 01/24/20 08:35 Received: 01/24/20 10:28 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed GAS No. Qual HEM, Oil and Grease Analytical Method: EPA 1664B Oil and Grease ND mg1L 5.0 1 01128/20 16:46 2540D Total Suspended Solids Analytical Method: SM 2540D-2011 Total Suspended Solids 2.5 mglL 2.5 1 01/28120 17:36 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 01/29/2020 03:45 PM without the written consent of Pace Analytical Services, LLC. Page 7 of 13 aceAnalytical www.pacelahs.cam QUALITY CONTROL DATA Pace Analytical ServieeS, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Project: GTA Pace Project No.: 92462213 QC Batch: 521887 Analysis Method: EPA 1664B QC Batch Method: EPA 1664B Analysis Description: 1664 HEM, Oil and Grease Associated Lab Samples: 92462213001, 92462213003, 92462213004 METHOD BLANK: 2791780 Matrix: Water Associated Lab Samples: 92462213001, 92462213003, 92462213004 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Oil and Grease mg/L ND 5.0 01/28/20 16:38 LABORATORY CONTROL SAMPLE: 2791781 Spike LCS 1-CS % Rec Parameter Units Conc. Result % Rec Limits Qualifiers Oil and Grease mg/L 40 39.8 100 78-114 MATRIX SPIKE SAMPLE: 2791782 2628201001 Spike MS MS % Rec Parameter Units Result Conc. Result % Rec Limits Qualifiers Oil and Grease mg/L ND 40 21,4 54 78-114 M1 Results presented on this page are in the units Indicated by the "Units" column except where an alternate unit is presented to the right or the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 01/29/2020 03:45 PM without the written consent of Pace Analytical Services, LLC. Page 8 of 13 aceAnalytical www.pacelabs.cem Project: GTA Pace Project No.: 92462213 QC Batch: 521892 QC Batch Method: EPA 1664B Associated Lab Samples: 92462213002 METHOD BLANK: 2791791 Associated Lab.Samples: 92462213002 Parameter Units Oil and Grease mg/L LABORATORY CONTROL SAMPLE: 2791792 Parameter Units Oil and Grease mg1L Pace Analytical Services, LLC 9800 KinceyAve. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Analysis Method: EPA 1664B Analysis Description: 1664 HEM, Oil and Grease Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 5.0 01/28/20 17:01 Spike LCS LCS % Rec Conc. Result % Rec Limits Qualifiers 40 31.8 80 78-114 MATRIX SPIKE SAMPLE: 2791793 92462213002 Spike MS MS % Rec Parameter Units Result Conc. Result % Rec Limits Qualifiers Oil and Grease mg1L ND 38.5 37.4 96 78-114 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presenter) to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in W, Date: 01/29/2020 03:45 PM without the written consent of Pace Analytical Services. LLC. Page 9 of 13 aceAnalytical www,pacelabs.com QUALITY CONTROL DATA Project: GTA Pace Project No.: 92462213 QC Batch: 521910 Analysis Method: SM 254OD-2011 QC Batch Method: SM 254OD-2011 Analysis Description: 2540D Total Suspended Solids Associated Lab Samples: 92462213001, 92462213002, 92462213003, 92462213004 Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 METHOD BLANK: 2791866 Matrix; Water Associated Lab Samples: 92462213001, 92462213002, 92462213003, 92462213004 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Total Suspended Solids mg/L ND 2.5 01128/20 17:33 LABORATORY CONTROL SAMPLE: 2791867 Spike LCS LCS % Rec Parameter Units Conc. Result % Rec Limits Qualifiers Total Suspended Solids mg/L 250 250 100 90-110 SAMPLE DUPLICATE: 2791868 92461868003 Dup Parameter Units Result Result RPD Qualifiers Total Suspended Solids mg/L 142 139 2 SAMPLE DUPLICATE: 2791869 92462443001 Dup Parameter Units Result Result RPD Qualifiers Total Suspended Solids mg/L 194 184 5 Results presented on this page are in the units Indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full. Date: 01/29/2020 03:45 PM without the written consent of Pace Analytical Services, LLC. Page 10 of 13 aceAnalytical Www,pacelabs.com QUALIFIERS Project: GTA Pace Project No.: 92462213 DEFINITIONS Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. ND - Not Detected at or above adjusted reporting limit. TNTC - Too Numerous To Count J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL -Adjusted Method Detection Limit. PQL - Practical Quantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenyihydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean -Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether. A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis of Acrolein and Acrylonitrile by EPA Method 8260. N-Nitrosod iphenyla mine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TNI - The NELAC Institute. LABORATORIES PASI-A Pace Analytical Services -Asheville PASI-C Pace Analytical Services - Charlotte ANALYTE QUALIFIERS M1 Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 01/29/2020 03:45 PM without the written consentof Pace Analytical Services, L.L.C. Page 11 of 13 aceAnalytical e www.pacelabs.com QUALITY CONTROL DATA CROSS REFERENCE TABLE Project: GTA Pace Project No.: 92462213 Lab ID Sample ID QC Batch Method QC Batch 92462213001 SDO-001 EPA 1664E 521887 92462213002 SOO-002 EPA1664B 521892 92462213003 SDO-003 EPA 1664B 521887 92462213004 SDO-004 EPA 1664B 521887 92462213001 SDO-001 SM 254OD-2011 521910 92462213002 SDO-002 SM 254OD-2011 521910 92462213003 SDO-003 SM 254OD-2011 521910 92462213004 SDO-004 SM 2540D-2011 521910 Date: 01/29/2020 03A5 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)8759092 Analytical Method Analytical Batch Page 12 of 13 S!R SPEEDY PRINTING CENTER MINNEAPOLIS. MN 55414 • 672-378-7778 _ a Customer Remarks /Special Conditions/ Possible Hazards: ReliRgvished by/Company: ignatvrel Date/Trme•. Received b Comny_,��,Iiur,2 Date�me: �'�-'MTlLUs / Y `J :Table it PJ _ AcctnuiTxit Relil�vished by/Company: Signature Dated TT eceiv ComnanV:{ Q e)! lur; DatelTrTi�t-C+ i I f IS• `- USGS 02094770 SOUTH BUFFALO CREEK AT US 220 AT GREENSBORO, NC PROVISIONAL DATA SUBJECT TO REVISION Timeseries Da3� data GO O Click to hide station -specific text AOil This station is operated in cooperation with the Lity of Greensboro, North Carolina. 6REEHS90Ra This station managed by the South AtlanUC VISC Raleigh Field Office. available Parameters Period of Record Output format Days (9)� GO ❑ All 3 Available Rararneters for this site G Graph O Graph w/ stats-- �. 00045 precipltatlon(Sum) 1999-09-30 2020-02-02 G Graph w/ meas Begin ❑ 000e0 Discharge{Vlax.,fgin.,liean) 1998-08-01 2020-02-02 O Graph w/ (up to 3) parms date zaza-0t zE ❑ OOD65 Cage height(Max.,Mi. Mean) 1998-07-71 2020-02-02 Table ` O Tab separated End date .2020-01 24 Summary_of all available data for this site Daily SUitl Precipitation, f)ATE Jan _ 2020I 24 11.27p— (COUNT MAX MIN_- __ -- Explanation ___ -_ . fF_ R Provisional data subject to revisiolJl Environmental Quatily Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report Forguidance onfilling ow lhisform, please visit hops://deq.ne.gov/aboiit/divisioi)s/energy-mineral-land-resources/ npdcs-stornnvater-gps Perm it No.: N/C/ l l / l l l / or Certificate of Coverage No.: NIC/G/ 0 / 8 IO 1 0l 0 / 0 / Facility Name: Greensboro Transit Authority (GTA) County: Guilford Phone No. 336-709_82 4 Inspector: I,orien Deaton Date of Inspection: January 24. 2020 Time of Inspection: 0805 Total Event Precipitation (inches): 1.27 All permits require qualitative monitoring to be performed during a "measurable storm event." A "measurable storm event" is a storm event that results in an actual discharge from the permitted site outfall. The previous measurable storm event must have been at least 72 hours prior. The 72-11our storm interval does not apply if the permittee is able to document that a shorter interval is representative for local storm events during the sampling period; and the permittee obtains approval from the local DEMI-R Regional Off ice. By this signature. I certify that this report is accurate and complete to the best of my knowledge: (Signature of lermittee or Designee) 1. Outfall Description: Outfall No. 001 Structure (pipe, ditch, etc.): _pipe Receiving Stream: South Suftalo ('t'eek - Describe the industrial activities that occur within the Outfall drainage area: Vehicle maintenance, bus _parking_ and employee parking. _.. Page 1 oI'2 SWIJ-242, Lmt modified 06/01/2013 2. Color: Describe the color of the discharge using basic colors (red, brown, blue, etc.) and tint (light, medium, dark) as descriptors: Clear, no color or tint 3. Odor: Describe any distinct odors that the discharge may have (i.e., smells strongly of oil, weak chlorine odor, etc.): none 4. Claritv: Choose the number which best describes the clarity of the discharge, where I is clear and 5 is very cloudy: IQ 2 3 4 5 5. Floating Solids: Choose the number which best describes the amount of floating solids in the storinwater discharge, where 1 is no solids and 5 is the surface covered with floating solids: Q 2 3 4 5 6. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge, where 1 is no solids and 5 is extremely muddy: IQ 2 3 4 5 7. Is there any foam in the stormwater discharge? O Yes �X No. S. 9. Is there an oil sheen in the stormwater discharge? OYes cN) No. Is there evidence of erosion or deposition at the outfall? O Yes 9No. 10. Other Obvious Indicators of Stormwater Pollution: List and describe None Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of pollutant exposure. These conditions warrant further investigation. Page 2 of 2 SwU-242, Last modified 06/01120t8 linvironmen tut Quality Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report hor guidance onfillingout fhisform, please risil littps://deq.nc.gov/,tbotit/divisions/energy-mineral-land-resources/ n pdes- storm water-gps Permit No.: N/C/ l 1 1 1 1 1 1 or Certificate of Coverage No.: N/CIG/ 0 1.8 /0 l 0/ 0/ 0/ Facility Name: Greensboro Transit Authority (GTA) County: Guilford Phone No. 336-209-$934 Inspector. Lorien Dcaton Date of Inspection: ]anuary 24. 2020 Time of' Inspection: 0815 Total Event Precipitation (inches): 1.27 All permits require qualitative monitoring to be performed during a `'measurable storm event." A "measurable storm event" is a storm event that results in an actual discharge from the permitted site OWN]], The previous measurable storm event must have been at least 72 IIOUrs prior. Tile 72-hour storm interval does not apply ifthe permittee is able to document that a shorter interval is representative for local storm events during the sampling period, and the permiltee obtains approval from the local DEMLR Regional Office. 13v this signature, 1 certify that this report is accurate and complete to the best of my knowledge: (Signature of Permittee or Designee) 1. Outfall Description: Outfall No. 002 Structure (pipe, ditch, etc): ape Receiving Stream: South Buffalo Creek Describe the industrial activities that occur within the outfall drainage area: V } i lainWnancQ, bus narking, and employee parking. Pa-e I of 2 SWIJ-242, Lust modified 06/01/2018 2. Color: Describe the color of the discharge using basic colors (red, brown, blue, etc.) and tint (light, medium, dark) as descriptors: clear 3. Odor: Describe any distinct odors that the discharge may have (i.e., smells strongly of oil, weak chlorine odor, etc.): none 4. Clarity: Choose the number which best describes the clarity of the discharge, where 1 is clear and 5 is very cloudy: QI 2 3 4 5 5. Floating Solids: Choose the number which best describes the amount of floating solids in the stormwater discharge, where I is no solids and 5 is the surface covered with floating solids: IQ 2 3 4 5 6. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge, where 1 is no solids and 5 is extremely muddy: Cl 2 3 4 5 7. 8. 9. Is there any foam in the storinwater discharge? O Yes (N) No. Is there an oil sheen in the stormwater discharge? OYes O� No. is there evidence of erosion sir deposition at the outfall? O Yes O� No. 10. Other Obvious Indicators of Stormwater Pollution: List and describe None Note: Lois, clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of pollutant exposure. These conditions ss'arrant further investigation. Page 2 of 2 SWU-242, Last modified 06/01/2018 Environmenlal Quality Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report Forgxiclance onfillingow lhisform, please visil https://deq.nc.gov/about/divisions/energy-mineral-land-resources/ npdes-stomlwater-gps Permit No.: N/CI / 1 I I 1 / I or Certificate of Coverage No.: N/C/Gl0 I S l0 /. 0 /. 0 /. 0 / Facility Name: Greensboro Transit Authority (GTA) County: Guilford Phone No. _336-2Q28gj4 Inspector: Lorien Deaton Date of -Inspection: January 2d. 2020 Time of Inspection: 0825 'total Event Precipitation (inches): 127 All permits require qualitative monitoring to be performed during a "measurable storm event." A "measurable storm event" is a storm event that results in an actual discharge from the permitted site outfall. The previous measurable storm event must have been at least 72 hours prior. The 72-hour storm interval does not apply if the permittee is able to doclElllenl that a shorter interval is representative for local storm events during the sampling period, and the permittee obtains approval from the local DEMLR Regional Office. fay this signature, I certify that this report is accurate and complete to the best of my knowledge: (Signature of Permittee or Aignee) 1. Outfall Description: Outfall No. 003 Structure (pipe; ditch, etc.): e Receiving Stream: e.. Describe the industrial activities that occur within the oLttf"lll drainage area: Vehicle mainte is -parking. and employee parking, — Page I of 2 SwU-2,12, Last modified 06/01/201 R 2. Color: Describe the color of the discharge using basic colors (red, brown, blue, etc.) and tint (light, mcdiUnl, dark) as descriptors: clear 3. Odor: Describe any distinct odors that the discharge may have (i.e., smells strongly of oil, weak chlorine odor, etc.): none 4. Clarity: Choose the number which best describes the clarity of the discharge, where l is clear and 5 is very cloudy: © 2 3 d 5 5. Floating Solids: Choose the number which best describes the amount of floating solids in the stormwater discharge, where l is no solids and 5 is the surface covered with floating solids: l 0 3 4 5 6. Suspendcd Solids: Choose the number which best describes the amount of suspended solids in the slormwater discharge, where I is no solids and 5 is extremely muddy: 0 2 3 4 5 7. 8. 9. Is there any foam in the stom►water discharge? O Yes d§ No. Is there an oil sheen in the stormwater discharge? 0Yes ® No. 1 - f , Is there evidence of erosion or deposition at the outfall? o Yes (M No. 10. Other Obvious Indicators of Stornmater Pollution: List and describe Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of Pollutant exposure. These conditions warrant further investigation. Page 2 ol'2 S\1'l]-242, Last modified 06101/2018 'a Environmental Quality Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report Forguidance oltfilling ow thisform, please 1'ixil https:/Icicq.tic.govlabout/divisions/energy-mineral-land-resources/ npdes-Stormwater-gpS Perm it No.: N/CI l I 1 1 1 / / or Certificate of Coverage No.: NIC/G/ O /.8 10 / 0 / 0 / 0 / Facility Name: GreensboroTransit Authority GTA County: Guilford Phone No. 336-709-Sq, Inspector: a , Date of Inspection: January 24, 2020 Time ol' Inspection: 0830 'Dotal Invent Precipitation (inches): 127 All permits require qualitative monitoring to be performed during a "measurable storm event.'" A "measurable storm event" is a storm event that results in an actual discharge from the permitted site outfalI. The previous measurable storm event must have been at least 72 hours prior. The 72-1101-ir storm interval does not apply if the permittee is able to document that a shorter interval is representative for local storm events during the sampling period, and the permittee obtains approval from the local DEMI.R Regional Office. By this signature, I certify that this report is accurate and complete to the best of my knowledge: tore of Permittee or Designee) 1. Outfall Description: Outlall No. 004 Structure (pipe, ditch, etc.): pipe Receiving Stream: South Buffalo Creel: Describe the industrial activities that occur within the outfall drainage area: Vehicle maintenance, bus parking. and employee parking. Page I of 2 SWU-242, Lwst modified 06/01/2018 2. Color: Describe the color of the discharge using basic colors (red, brown, blue, etc.) and tint (light, medium, dark) as descriptors: clear 3. Odor: Describe any distinct odors that the discharge may have (i.e., smells strongly of oil, weak chlorine odor; etc.): none 4. Clarity: Choose the number which best describes the clarity of the discharge, where 1 is clear and 5 is very cloudy: l Q 3 4 5 5. Floating Solids: Choose the number which best describes the amount of floating solids in the stormwater discharge; where l is no solids and 5 is the surface covered with floating solids: r 1 2 Q 4 5 6. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge, where 1 is no solids and 5 is extremely muddy: 2 3 4 5 7. Is there anv foam in the stormwater discharge? 0� Yes O No. small amount further inside pipe 8. 9. Is there an oil sheen in the stormwater discharge? OYes ® No. Is there evidence of erosion or deposition at the outf311? O Yes Q No. 10. Other Obvious indicators of StorniNvater Pollution: List and describe Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of pollutant exposure. These conditions warrant further investigation. Page 2 oF2 swtJ-242, Last modified 06/01/2018