Loading...
HomeMy WebLinkAboutNCG080811_MONITORING INFO_20200128Argo STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. IV CCU O ° DOC TYPE ❑HISTORICAL FILE CP(MONITORING REPORTS DOC DATE ❑ J�� YYYYMMDD AA AMOUNTAIN Environmental Services January 22, 2020 Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, NC 27699-1617 RE: Storm Water Discharge Outfali Monitoring Report Asheville Oil Company 4 Fairview Road Asheville, NC Certificate of Coverage No. NCG080811 Permit No. NCG080000 • assessment • remediation • waste management JAN 2 S ZUZD CEN_1'w-\L FtLl✓ U) R SECTIOI l Attached please find the Storm Water Discharge Outfall Monitoring Report (SDO) for the referenced site. If you have any questions, please feel free to contact me. I can be reached by phone at (828) 648-5556 or by e-mail at bbauer@mtnenv.com. Sincerely Mountain Environmental Services 1 Brian Bauer Project Manager Attachments: cc: Landon Davidson-NCDEQ Brett Laverty-NCDEQ Drew Thorpe -Asheville Oil 1560 Pisgah Drive PHONE- (828) 648-5556 Canton, NC 28716 (800) 261-0031 www.mountainenvironmental.com FAX. (828) 648-1566 WA 91- NCDENR Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report For guidance on filling out this form, please visit: Permit No.: or Certificate of Coverage No.: N/L/C//,L/1/ Facility Name: ASHEVILLE OIL COMPANY County: BUNCOMBE Phone No. Inspector: BRIAN BAUER Date of Inspection: _ I-! y-Z v Time of Inspection: S'o� Total Event Precipitation (inches): 0.5 829-274-7978 Was this a "Representative Storm Event" or "Measureable Storm Event" as defined by the permit? (See information below.) ® Yes ❑ No Please verify whether Qualitative Monitoring must be performed during a "representative storm event" or "measureable storm event" (requirements vary, depending on the permit). Qualitative monitoring requirements vary. Most permits require qualitative monitoring to be performed during a "representative storm event" or during a "measureable storm event." However, some permits do nothave this requirement. Please refer to these definitions, if applicable. A "representative storm event" is a storm event that measures greater than 0.1 inches of rainfall and that is preceded by at least 72 hours (3 days) in which no storm event measuring greater than 0.1 inches has occurred. A single storm event may contain up to 10 consecutive hours of no precipitation. A "measurable storm event" is a storm event that results in an actual discharge from the permitted site outfall. The previous measurable storm event must have been at least 72 hours prior. The 72-hour storm interval does not apply if the permittee is able to document that a shorter interval is representative for local storm events during the sampling period, and the permittee obtains approval from the local DWQ Regional Office. By this signature, I certify that this report is accurate and complete to the best of my knowledge: 1 /22/20 (Signature of Permittee or Designee) Page 1 of 2 SWU-242, Last modified 7/31/2013 1. Outfall Description: Outfall No. SDO-1 Structure (pipe, ditch, etc.) DISCHARGE PIPE Receiving Stream: SWEETEN CREEK Describe the industrial activities that occur within the outfall drainage area: BULK PETROLEUM DISTRIBUTORS, COMMERCIAI. CAR WASHES, AUTO REPAIR, INDUSTRIAL. 2. Color: Describe the color of the discharge using basic colors (red, brown, blue, etc.) and tint (light, medium, dark) as descriptors: LIGHT BROWN STAINING 3. Odor: Describe any distinct odors that the discharge may have (i.e., smells strongly of oil, weak chlorine odor, etc.): NO ODOR 4. Clarity: Choose the number which best describes the clarity of the discharge, where 1 is clear and 5 is very cloudy: 1 2 0 4 5 5. Floating Solids: Choose the number which best describes the amount of floating solids in the stormwater discharge, where 1 is no solids and 5 is the surface covered with floating solids: 1 O 3 4 5 G. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge, where 1 is no solids and 5 is extremely muddy: 1 © 3 4 5 7. Is there any foam in the stormwater discharge? Yes No 8. Is there an oil sheen in the stormwater discharge? Yes f0 9. Is there evidence of erosion or deposition at the outfall? Yes No 10. Other Obvious Indicators of Stormwater Pollution: List and describe NA Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of pollutant exposure. These conditions warrant further investigation. Page 2 of 2 SM-242, Last modified 7/31/2013 lth NCDENR Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report Forguidance on filling out this form, please visit: http1//portal.ncdennarg/web11r/npdes-stormwater/ Permit No.: or Certificate of Coverage No.: Facility Name: ASHEVILLE OIL COMPANY County: BUNCOMBE Phone No. 828-274-7978 Inspector: BRIAN BAUER Date of Inspection: Time of Inspection dUC7 Total Event Precipitation (inches): 0.5,_� Was this a "Representative Storm Event" or "Measureable Storm Event" as defined by the permit? (See information below.) © Yes ❑ No Please verify whether Qualitative Monitoring must.be performed during a "representative storm event" or "measureable storm event" (requirements vary, depending on the permit). Qualitative monitoring requirements vary. Most permits require qualitative monitoring to be performed during a "representative storm event" or during a "measureable storm event." However, some permits do not have this requirement. Please refer to these definitions, if applicable. A "representative storm event" is a storm event that measures greater than 0.1 inches of rainfall and that is preceded by at least 72 hours (3 days) in which no storm event measuring greater than 0.1. inches has occurred. A single storm event may contain up to 10 consecutive hours of no precipitation. A "measurable storm event" is a storm event that results in an actual discharge from the permitted site outfall. The previous measurable storm event must have been at least 72 hours prior. The 72-hour storm interval does not apply if the permittee is able to document that a shorter interval is representative for local storm events during the sampling period, and the permittee obtains approval from the local DWQ Regional Office. By this signature, i certify that this report is accurate and complete to the best of my knowledge: 4,4. 6?. 1/22/20 (Signature of Permittee or Designee) Page 1 of 2 SWU-242, Last modified 7/31/2013 1. Outfall Description: Outfall No. SDO-2 Structure (pipe, ditch, etc.) DISCHARGE PIPE. Receiving Stream: SWEETEN CREEK Describe the industrial activities that occur within the outfail drainage area: BULK PETROLEUM DISTRIBUTORS, COMMERCIAL CAR WASHES, AUTO REPAIR, INDUSTRIAL. Z. Color: Describe the color of the discharge using basic colors (red, brown, blue, etc.) and tint (light, medium, dark) as descriptors: LIGHT BROWN 3. Odor: Describe any distinct odors that the discharge may have (i.e., smells strongly of oil, weak chlorine odor, etc.): NO ODOR 4. Clarity: Choose the number which best describes the clarity of the discharge, where 1 is clear and 5 is very cloudy: 1 Q 3 4 5 S. Floating Solids: Choose the number which best describes the amount of floating solids in the stormwater discharge, where 1 is no solids and 5 is the surface covered with floating solids: 1 O2 3 4 5 6. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge, where 1 is no solids and 5 is extremely muddy: 1 ® 3 4 5 7. Is there any foam in the stormwater discharge? Yes No 8. Is there an oil sheen in the stormwater discharge? Yes 9. Is there evidence of erosion or deposition at the outfall? Yes No 10. Other Obvious Indicators of Stormwater Pollution: List and describe NA Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of pollutant exposure. These conditions warrant further investigation. r Page 2 of 2 SWU-242, Last modified 7/31/2013 STORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT GENERAL PERMIT NO. NCGO80000 CERTIFICATE OF COVERAGE NO. NCGO80811 FACILITY NAME ASHEVILLE OIL PERSON COLLECTING SAMPLES BRIAN BAUER CERTIFIED LABORATORY PACE ANALYTICAL Lab #40 Lab #37712_ SAMPLES COLLECTED DURING CALENDAR YEAR: 2020 (This monitoring report is due at the Division no later than 30 days from the date the facility receives the sampling results from the laboratory.) COUNTY BUNCOMBE PHONE NO. (828) 648-5556 PLEASE SIGN ON THE REVERSE � Part A: Vehicle Maintenance Areas Monitoring Requirements Did this facility perform Vehicle Maintenance Activities using more than 55 gallons of new motor oil per month?_ yes X no (if yes, report your analytical results in the table immediately below) Outfall No. Date Sample. Collected, mo/dd/ r 00530 00400 00556 Total Suspended Solids, mg/L pH, Standard units Oil and Grease, mg/IL New Motor.Oil Usage,, Annual average gal/mo Benchmark 100 Within 6.0 — 9.0 -30 - Note: If you report a sampled value in excess of the benchmark value, or outside the benchmark range for pH, you must implement Tier I or Tier 2 responses. See General Permit text. Part B: Oil/water Separators and Secondary Containment Areas at Petroleum Bulk Stations and Terminals Outfall No. Date Sample Collected, mo/ddl r. 00556 _ `00530 00400 Oil and'Grease, m L .' Total Stspended Solids, 7i /L pH,` Standard -units' Permit Limit - 30 100 6.0, 9.D SDO-I 1 /28/2009 6.4 18 6.03 SDO-I 7/31/2009 5.6 NA -Lab Error w/ sample 6.54 SDO-1 2/2/2010 None Detected 24.3 6.87 SDO-1 8/2/2010 None Detected 5.6 5.98 SDO-1 1/24/2011 None Detected None Detected 6.65 SDO-1 8/9/2011 None Detected 211 7.1 SDO-I 3/9/2012 None Detected Not Enough Sample 6.68 SDO-1 1/2/2013 None Detected None Detected 5.45 SDO-1 1/31/2014 9.5 Not Enough Sample 7.12 SDO-1 10/7/2016 None Detected 16.3 6.5 SDO-1 6/21/2018 None Detected 19.3 7.3 SDO-I 12/14/18 None Detected 11.8 7.2 SDO- l 7/24119 ND 33.4 7.1 SDO-1 1/14/20 ND 184 ND S WU-25 0-102107 Page I of 2 STORM EVENT CHARACTERISTICS: Date _1/28/2009 (first event sampled) Total Event Precipitation (inches): 0.2— Date _7/31/2009 (list each additional event sampled this reporting period, and rainfall amount) Total Event Precipitation (inches): _0.3 Date _212/2010 (list each additional event sampled this reporting period, and rainfall amount) Total Event Precipitation (inches): _0.75 Date _8/2/2010 (list each additional event sampled this reporting period, and rainfall amount) Total Event Precipitation (inches): �0.05 Date _1/24/2011 (list each additional event sampled this reporting period, and rainfall amount) Total Event Precipitation (inches): _0.03 Date ^8/9/2011 (list each additional event sampled this reporting period, and rainfall amount) Total Event Precipitation (inches): .035 Date _3/9/2012 (list each additional event sampled this reporting period, and rainfall amount) Total Event Precipitation (inches): .0.43 Date _1/2/2013 (list each additional event sampled this reporting period, and rainfall amount) Total Event Precipitation (inches): .0.29 Date _1/31/2014 (list each additional event sampled this reporting period, and rainfall amount) Total Event Precipitation (inches): .0.09 Mail Original and one copy to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 SWU-250-102107 Page 2 of 2 Date _10/7/2016 (list each additional event sampled this reporting period, and rainfall amount) Total Event Precipitation (inches): .0.45 Date _6/21/2018 (list each additional event sampled this reporting period, and rainfall amount) Total Event Precipitation (inches): .0.30 Date _12/14/18 (list each additional event sampled this reporting period, and rainfall amount) Total Event Precipitation (inches): 2.0 Date Y7/24/19 (list each additional event sampled this reporting period, and rainfall amount) Total Event Precipitation (inches): 1.0 Date _1/14/20 (list each additional event sampled this reporting period, and rainfall amount) Total Event Precipitation (inches): 0.5 "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) 1/22/20 (Date) SVVU-250-102107 Page 3 of 2 GENERAL PERMIT NO. ,NCG080000 CERTIFICATE OF COVERAGE NO. NCGO80811 FACILITY NAME ASHEVILLE OIL PERSON COLLECTING SAMPLES BRIAN BAUER CERTIFIED LABORATORY PACE ANALYTICAL STORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT Lab #40 Lab #37712 SAMPLES COLLECTED DURING CALENDAR YEAR: 2020 (This monitoring report is due at the Division no later than 30 days from the date the facility receives the sampling results from the laboratory.) COUNTY BUNCOMBE PHONE NO. (828) 648-5556 PLEASE SIGN ON THE REVERSE 4 Part A: Vehicle Maintenance Areas Monitoring Requirements Did this facility perform Vehicle Maintenance Activities using more than 55 gallons of new motor oil per month?_ yes X no (if yes, report your analytical results in the table immediately below) Outfell No. -- Date Sample Collected, mo/ddl r 00530 00400 = 00556 - Total Suspended Solids, mg/L pH, Standard units Oil and Grease, mg/L New Motor Oil Usage, Annual average gaUmo Benchmark _ - 100 Within 6.0 — 9.0, 30 - Note: If you report a sampled value in excess of the benchmark value, or outside the benchmark range for pH, you must implement Tier 1 or Tier 2 responses. See General Permit text. Part B: Oil/water Separators and Secondary Containment Areas at Petroleum Bulk Stations and Terminals Outfall No.. Date" Sample Collected, . mo/dd/ r -.00556.1 00530 00400` _Oil and Grease, mg/L Total Suspended Solids, mg/L - pH, Standard units Permit Limit - 30 _ "100, 6.0 — 9.0 SDO-2 6/21/2018 None Detected 19.2 7.3 SDO-2 12/14/18 None Detected 9.1 7.1 SDO-2 7/24/19 ND ND 6.7 SDO-2 1 / 14/20 ND 147 5.3 STORM EVENT CHARACTERISTICS: Date 6/21//2018 (first event sampled) Total Event Precipitation (inches):.2.0 Mail Original and one copy to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 SW`U-250-102107 Page] of 2 Date _12/14/18 (list each additional event sampled this reporting period, and rainfall amount) Total Event Precipitation (inches): _2.0 Date _7/24/19 (list each additional event sampled this reporting period, and rainfall amount) Total Event Precipitation (inches): _1.0 Date _1/14/20 (list each additional event sampled this reporting period, and rainfall amount) Total Event Precipitation (inches): _0.5 "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." 1 /22/20 (Signature of Permittee) (Date) S WU-250- l 02107 Page 2 of 2 aceAnalytrcal " www.Dacelaba.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 January 21, 2020 Mr. Brian Bauer Mountain Environmental 1560 Pisgah Drive Canton, NC 28716 RE: Project: A0C/0-A0C01-1 C 1 /14/20 Pace Project No.: 92460531 Dear Mr. Bauer: Enclosed are the analytical results for sample(s) received by the laboratory on January 14, 2020. The results relate only to the samples included in this report. Results reported herein conform to the most current, applicable TNVNELAC standards and the laboratory's Quality Assurance Manual, where applicable, unless otherwise noted in the body of the report. If you have any questions concerning this report, please feel free to contact me. Sincerely, Chris Derouen for Lord Patton lorri.patton@pacelabs.com 1(828)254-7176 Project Manager Enclosures �ipCCR� REPORT OF LABORATORY ANALYSIS This report shall not he reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 1 of 11 aceAnalytical o www.patelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 CERTIFICATIONS Project: A0C10-A0C01-1C 1114/20 Pace Project No.: 92460531 Pace Analytical Services Charlotte 9800 KinceyAve. Ste 100, Huntersville, INC 28078 South Carolina Certification #: 99006001 Louisiana/NELAP Certification # LA170028 Florida/NELAP Certification #: E87627 North Carolina Drinking Water Certification #: 37706 Kentucky UST Certification #: 84 North Carolina Field Services Certification #: 5342 VirginiaNELAP Certification #: 460221 North Carolina Wastewater Certification #: 12 Pace Analytical Services Asheville 2225 Riverside Drive, Asheville, NC 28804 North Carolina Wastewater Certification #: 40 Florida/NELAP Certification #: E87648 South Carolina Certification #: 99030001 Massachusetts Certification #: M-NC030 VirginiaNELAP Certification #: 460222 North Carolina Drinking Water Certification #: 37712 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except In full, without the written consent of Pace Analytical Services, LLC. Page 2 of 11 aceAnalytical www.Pac1lab3.eam Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 SAMPLE ANALYTE COUNT Project: AOC10-A0001-IC 1114120 Pace Project No.: 92460531 Analytes Lab ID Sample ID Method Analysts Reported Laboratory 92460531001 OUTFALL-1 EPA 1664B HH 1 PASI-C SM 2540D-2011 CJL 1 PASI-A SM 4500-H+B-2011 ECH 1 PASI-A 92460531002 OUTFALL-2 EPA 1664B HH 1 PASI-C SM 2540D-2011 CJL 1 PASI-A SM 4500-H+B-2011 ECH 1 PASI-A REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 3 of 11 aceAnalj&a14' www,pacelebs.cam Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 ANALYTICAL RESULTS Project: AOC/0-A0001-IC 1114/20 Pace Project No.: 92460531 Sample: OUTFALL71 Parameters Lab -ID: 92460531001 Collected: 01/14/20 08:15 Results Units Report Limit DF Received: 01/14/20 10:00 Matrix: Water Prepared Analyzed GAS No. Qua[ HEM, Oil and Grease Analytical Method: EPA 1664B Oil and Grease ND mg1L 4.8 1 01/16/20 15:59 25400 Total Suspended Solids Analytical Method: SM 2540D-2011 Total Suspended Solids 184 mg/L 25.0 1 01/17/20 16:57 4500H+ pH, Electrometric Analytical Method: 5M 4500-H+B-2011 pH at 25 Degrees C 5.3 Std. Units 0.10 1 01/20120 11.03 H3 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 01121 /2020 04:21 PM without the written consent of Pace Analytical Services, t_LC. Page 4 of 11 aceArral 441 www,pacellbs.cam Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254.7176 ANALYTICAL RESULTS Project: A0C10-A0C01-1C 1114/20 Pace Project No.: 92460531 Sample: OUTFALL-2 Lab ID: 92460531002 Collected: 01/14/20 08:00 Received: 01/14/20 10:00 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual HEM, Oil and Grease Analytical Method: EPA 1664B Oil and Grease ND mg1L 4.8 1 D1116120 15:59 2540D Total Suspended Solids Analytical Method: SM 2540D-2011 Total Suspended Solids 147 mglL 25.0 1 01/17/20 16:57 4500H+ pH, Electrometric Analytical Method: SM 4500-H+8-2011 pH at 25 Degrees C 5.3 Std. Units 0.10 1 01/20/20 10:57 H3 Date: 01/21/2020 04:21 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC, Page 5 of 11 aceArralykal www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA Project: A0C10-A0C01-1C 1/14/20 Pace Project No.: 92460531 QC Batch: 519800 Analysis Method: EPA 1664B OC Batch Method: EPA 16648 Analysis Description: 1664 HEM, Oil and Grease Associated Lab Samples: 92460531001, 92460531002 METHOD BLANK: 2781839 Matrix: Water Associated Lab Samples: 92460531C01, 92460531002 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Oil and Grease mg/L ND 5.0 01/16/20 15:56 LABORATORY CONTROL SAMPLE: 2781840 Spike LCS LCS % Rec Parameter Units Conc. Result %n Rec Limits Qualifiers Oil and Grease mg1L 40 36.1 90 78-114 MATRIX SPIKE SAMPLE: 2781841 92460861001 Spike MS MS % Rec Parameter Units Result Conc. Result % Rec Limits Qualifiers Oil and Grease mg/L ND 38.5 12.2 32 78-114 M1 Results presented on this page are In the units indicated by the "Units" column except where an alternate unit Is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 01 /21/2020 04:21 PM without the written consent of Pace Analytical Services, LLC. Page 6 of 11 aceAnalX cal www.pacelabs.com Pace Analytical Services, 1-I-C 2225 Riverside Dr. Asheville, NC 28804 (828)254-7176 QUALITY CONTROL DATA Project: A0C10-A0C01-1C 1114/20 Pace Project No.: 92460531 QC Batch: . 520057 Analysis Method: SM 254OD-2011 QC Batch Method: SM 254OD-2011 Analysis Description: 2540D Total Suspended Solids Associated Lab Samples: 92460531001, 92460531002 METHOD BLANK: 2783143 Matrix: Water Associated Lab Samples: 92460531001, 92460531002 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Total Suspended Solids mg1L ND 2.5 01/17/20 16:52 LABORATORY CONTROL SAMPLE: 2783144 Spike LCS LCS % Rec Parameter Units Conc. Result % Rec Limits Qualifiers Total Suspended Solids mg1L 250 254 102 90-110 SAMPLE DUPLICATE: 2783145 92460641D01 Dup Parameter Units Result Result RPD Qualifiers Total Suspended Solids mg/L 17.5 16.5 6 SAMPLE DUPLICATE: 2783146 92460764003 Dup Parameter Units Result Result RPD Qualifers Total Suspended Solids mg/L 1420 1220 15 Results presented on this page are In the units Indicated by the "Units" column except where an alternate unit Is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 01121 /2020 04:21 PM without the written consent of Pace Analytical Services, LLC. Page 7 of 11 aceAnalyflcal v www.pactiabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804. (828)254a176 QUALITY CONTROL DATA Project: A0C10-A0C01-1C 1/14/20 Pace Project No.: 92460531 QC Batch: 520142 Analysis Method: SM 4500-H+B-2011 OC Batch Method: SM 4500-H+B-2011 Analysis Description: 4500H+B pH Associated Lab Samples: 92460531001. 92460531002 SAMPLE DUPLICATE: 2783509 92460031001 Dup Parameter Units Result Result RPD Qualifiers pH at 25 Degrees C Std. Units 6.8 6.7 2 D6,H3 Results presented on this page are In the units Indicated by the -Units" column except where an alternate unit Is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except In full, Date: 01/21/2020 04:21 PM without the written consent of Pace Analytical Services, LLC. Page 8 of 11 aceAnalj cal www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 f828)254-7176 QUALIFIERS Project: A0CI0-A0C01-1C 1/14120 Pace Project No.: 92460531 DEFINITIONS DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. ND - Not Detected at or above adjusted reporting limit. TNTC - Too Numerous To Count J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL -Adjusted Method Detection Limit. PQL - Practical Quantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyto in a specific matrix. S - Surrogate 1,2-Diphenythydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) ❑UP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean -Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether. A separate vial preserved to a pH of 4-5 is recommended in SWB46 Chapter 4 for the analysis of Acrolein and Acrylonitrile by EPA Method 8260. N-Nitrosodiphenyla mine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TNI - The NELAC Institute. LABORATORIES PASI-A Pace Analytical Services - Asheville PASI-C Pace Analytical Services - Charlotte ANALYTE QUALIFIERS D6 The precision between the sample and sample duplicate exceeded laboratory control limits. H3 Sample was received or analysis requested beyond the recognized method holding time. M1 Matrix spike recovery exceeded QC limits. Balch accepted based on laboratory control sample (LCS) recovery. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except In full, Date: 01I2112020 04:21 PM without the written consent of Pace Analytical Services, LLC, Page 9 of 11 acmnalytical" www.pacelabs.com Pace Analytical Services, LLC 2225 Riverside Dr. Asheville, NC 28804 (828)254.7176 QUALITY CONTROL DATA CROSS REFERENCE TABLE Project: A0C10-A0C01-1C 1114120 Pace Project No.: 92460531 Analytical Lab lD Sample ID QC Batch Method QC Batch Analytical Method Batch 92460531001 OUTFALL-1 EPA1664B 519800 92460531002 OUTFALL-2 EPA 1664B 519800 92460531001 OUTFALL-1 SM 2540D-2011 520057 92460531002 OUTFALL-2 SM 254OD-2011 520057 92460531001 OUTFALL-1 SM 4500-H+B-2011 520142 92460531002 OUTFALL-2 SM 4500-H+B-2011 520142 Date: 01/21/2020 04:21 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 10 of 11 ' CHAIN -OF -CUSTODY Analytical Requ WO# ■ 9246®531 -der/Login Label Here or List Pace WorkarderNumberor MTJL Login Number Here PaccAnalytical ` Chain -of -Custody is a LEGAL DOCUMENT- Complete Company: Billing Information: II I 4 I ° AREAS are for LAB USE ONLY Cek'/ 1 92460531 Addres . Lab Project Manager L L,ti Repo77h h Email To: " Preservative [5) methanol. (C) ammonium Types: f 1) nitric acid, 12) sulfuric acid, (3) h-,drochloric (7) sodium bisulfate, (8) sodium ;hiosulfate. (9) hydroxide, (D) TSP, (U) Unpreserved, (0) O:her acid, (4) sodium hydroxide; (51 zinc acetate, hexane, [A) ascorbic acid, (8) ammonium sulfate, Copy To: Site Collection Info/Address: Analyses Lab Profile/Line: Customer Pr jec Name/Number. Ae _4occI__g State: County/City: Time Zone Collected: / I )PT[ JMT[ JC.T [ JET r %� ! t, R Lab Sample Receipt Checklist. Custody Seals Present/Intact Y Q RA Custody Signatures Present N 1FA Collector Signature Present .iF HA Bottles Intact 11 t;A Correct Bottles N }FA Sufficient Volume 11 i'A Satrapies Received on ic CP N NA vDA - Headspace Acceptable Y N USDA Regulated Sails Y N Samples in }Iolding Time CV N HA Residual Chlorine Present y H STET Cl Strips:. - sample pH Acceptable y li PH Strips: Sulfide Present y N Lead Acetate strips: LAH USE ONLY Lab Sample � /-Coacmenta: � jI>✓�j f C,/ /7 ! `6 05$1 Phone: Email: Site/Facility ID ft: Compliance Monitoring? ( ] Yes f ]No ted By � Purchase Order#l: Quote H: DW PWS ID #: DW Location Code: o B - Turnaround Date ReR ilr�etd: S t A' �1 Immediately Packed on Ice: [ ] Yes [ ) ND Sample Disposal: ( ) Dispose as appropriate ( ) Return [ ] Archive: ( ]Hold: Rush: ( ] Same Day [ ] Next Day { ] 2 Day ( ] 3 Day [ ] 4 Day [ } 5 Day (Expedi[eCharges Apply) Field Filtered (if applicable): [ ) Yes [ ]No Analysis: ' Matrix Codes {Insert in Matrix box below): Drinking Water (DW), Ground Water (GW), Wastewater (WW), Product (P), Soil/Solid (SQ; Oil (OLJ, Wipe (WP), Air (AR), Tissue (TS), Bioassay (B), Vapor (V), Other (OT) Customer Sample ID Matrix ' Camp I Grab Collected for Composite.Start) Composite End Res Cl q of Ctns Date Time Date Time 01-'t1, FesLL--1 L l:� -f —a Customer Remarks / Special Conditions / Possible Hazards: Type of Ice Used: Wet Blue Dry None SHORT HOLDS PRESENT 1s72 hours): Y 'ice N/A Lab Sample Temperature Info: Temp Blank Received: Y �)NA Therm Ib!!: � 10, Cooler 1 Temp Upan Rereipt: t: [�oC Cooler 1 Therm Com;Factor: 0_or- Cooler 1 Corrected_ Temp:0oC Comments: Packing Material Ll jj. E� 171 1✓CMG r Lab Tracking N: 2 4 L Radchem sample(s) screened (<500 cpm): Y N NA Samples received via: FEDEX UPS Client Courier. Pace Courier nqU pang: (Signature) Date/Time: RV'Corftpa y: Si fure) � �-C Date/Time: !� ( MTJL LAB USE ONLY Tabled: Accmum: Relinquished by/Company: (Signature) Date/Time: E Received by/Company: (S)gnature) Date/Time.: Template: Prelogin: PM: P.B: Trip Blank Received: Y NA HCL McOH TSP Other Relinquished by/Company: (Signature) Date/Time: Received by/Company: (5ignature) Date/Time: Non Conform nce(s}: YES / N Page:. of: