Loading...
HomeMy WebLinkAboutNCG080770_MONITORING INFO_20140501STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. IVC& b�b-7 � u DOC TYPE ❑HISTORICAL FILE C�MONITORING REPORTS DOC DATE ❑ YYYYMMDD STORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT GENERAL PERMIT NO. NCG080000 SAMPLES COLLECTED DURING CALENDAR YEAR: CERTIFICATE OF COVERAGE NO. NCG08 0770 _ (This monitoring report is due at the Division no later than 30 days from the date the facility receives the sam ling results from the laboratory.) FACILITY NMN'IE opt/ L.1 COUNTY /%&ge Q. 51,1a (4029 } , PERSON COLLECTING SAMPLES fo PHONE NO. (R%Y/) S96 ZZZ^� t CERTIFIED LABORATORY L_ Lab # 1 QFq_god J Lab # PLEASE SIGN ON THE RI'VERSE Part A; Vehicle Maintenance Areas Monitoring Requirements Did this facility perform Vehicle Maintenance Activities using more than 55 gallons of new motor oil per month? —yes (if yes. report your analytical results in the table immediately below) Outfall No. Date Sample Collected, mo/dd/ r 00530 00400 00556 Total Suspended Solids, m pH, Standard units Oil and Grease, mgfL New Motor Oil Usage, Annual average al/mo Benchmark 100 - Within 6.0 — 9.0 30 !?m ! / o "s x© 1 X"%a V 201 Note: if you report a sampled value in excess of the benchmark value, or outside the benchmark range for pH, you must implement Tier �pr�7:Ic,r,2 V gpp�Ec See General Pernut text. DWQJBOG Part Ii: Oil/water Separators and Secondary Containment Areas at Petroleum Bulk Stations and Terminals Outrall No. Date Sample Collected, mo/dd/ r 00556 00530 00400 Oil and Grease, m g Total Suspended Solids, m /L pH, Standard units Permit Limit - 30 100 6.0 — 9.0 STORM EVENT CHARACTERISTICS: Date � %S ; (first event sampled) Total Eve t Precipitation (inches): 2— Date (list each additional event sampled this reporting period, and rainfall amount) Total Event Precipitation (inches): Mail Original and one copy to: Division of Water Quality Attu: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 SWU-250-102 J O7 Pa-c i „7 2 "I certify, under penalty of law, that this document and all attachments were prepared under nay direction or supervision in accordance with. a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." ao�L (Signature of Perk, ttee) ( ate) S W U-750-102107 Page I- (); I /IceAnalyfical" J WWW.AaCeiBbY.Wrr1 i April 25, 2014 Mr. Bob Newman Horizon Coach Lines 1251 W, Craighead Rd. Charlotte, NC 28206 RE: Project: OUTFALL Pace Project No.: 92197611 Dear Mr. Newman: Pace Analytical Services, Inc. 9800 KinceyAve. Suite 100 Huntersville, 128078 (704)875-9092 Enclosed are the analytical results for sample(s) received by the laboratory on April 16, 2014. The results relate only to the samples included in this report. Results reported herein conform to the most current TNI standards and the laboratory's Quality Assurance Manual, where applicable, unless otherwise noted in the body of the report. Analyses were performed at the Pace Analytical Services location indicated on the sample analyte page for analysis unless otherwise footnoted. If you have any questions concerning this report, please feel free to contact me. Sincerely, Vu i o t r( { Angela Baioni for Laura J Cooper laura.cooper@pacelabs.com Project Manager Enclosures A�CRfO/ �r TNI; REPORT OF LABORATORY ANALYSIS This report shall not be reproduced. except in full, without the written consent of Pace Analytical Services, Inc.. Page 1 of 11 aceAnalyticale www.pacelabs.corrt j Project: OUTFALL Pace Project No.: 92197611 Charlotte Certification IDs 9800 Kincey Ave. Ste 100, Huntersville, NC 28078 North Carolina Drinking Water Certification M 37706 North Carolina Field Services Certification #: 5342 North Carolina Wastewater Certification #: 12 South Carolina Certification #: 99006001 Asheville Certification IDs 2225 Riverside Dr., Asheville, NC 28804 FloridalNELAP Certification #: E87648 Massachusetts Certification #: M-NC030 North Carolina Drinking Water Certification #: 37712 CERTIFICATIONS Florida/NELAP Certification #: E87627 Kentucky UST Certification #: 84 West Virginia Certification #: 357 VirginiaNELAP Certification #: 460221 North Carolina Wastewater Certification South Carolina Certification #: 99030001 West Virginia Certification #: 356 VirginiaNELAP Certification #: 460222 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Pace Analydcal Servicos, Inc. 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (7 04 )875-9092 Page 2 of 11 J3 aceAnalytrcal V~ wwwpacalabs com I SAMPLE ANALYTE COUNT Project: OUTFALL Pace Project No.: 92197611 Pace Analytical Services, Inc. 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875.9092 Analytes Lab ID Sample ID Method Analysts Reported Laboratory 92197611001 OUTFALL #1 EPA 1664E CLW 1 PASI-C SM 2540D 1 WRC 1 PASI-A EPA9040 I MDW 1 PASI-A REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Page 3 of 11 /�;a'ce Analytical ' www.pacelabs.com ANALYTICAL RESULTS Project: OUTFALL Pace Project No.: 92197611 Pace Analytical Services, Inc. 9800 Kincey Ave. Suite 100 Huntersvilte, NC 28078 (704)875.9092 Sample: OUTFALL #1 Parameters Lab I0: 92197611001 Collected: 04/15/14 15:30 Results Units Report Limit DF Received: 04/16114 10:43 Matrix: Water Prepared Analyzed CAS No. Qual HEM, Oil and Grease Analytical Method: EPA 1664E Oil and Grease ND mg/L 5.0 1 04/17/14 11:31 2540D Total Suspended Solids Analytical Method: SM 2540D I Total Suspended Solids 25.4 mg/L 5.0 1 04F22/14 20:48 9040 pH Analytical Method: EPA 9040 pH 6.5 Sid. Units 0,10 1 0408114 13:30 H6 Date: 04/25/2014 09:48 AM REPORT OF LABORATORY ANALYSIS This report shalt not be reproduced, except in full, without the written consent of Pace Analytical Services, Ina. Page 4 of 11 aceAnarlytical www.pacel0s.com QUALITY CONTROL DATA Project: OUTFALL Pace Project No.: 92197611 OC Batch: GCSV117282 Analysis Method: EPA 1664B QC Batch Method: EPA 1664E Analysis Description: 1664 HEM, Oil and Grease Associated Lab Samples: 92197611001 METHOD BLANK: 1180267 Associated Lab Samples: 92197611001 Parameter Units Oil and Grease mg/L LABORATORY CONTROL SAMPLE: 1180268 Parameter Units Oil and Grease mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 5.0 04/17/1411:25 1 Spike LCS Corc. Result 40 38.5 Pace Anatytical Services, Inc. 9800 Kincey Ave. Suite 100 Huntersviile, NC 28078 (704)875-9092 LCS % Rec R e c Limits Qualifiers 96 78-114 MATRIX SPIKE SAMPLE: 1180269 92197663004 Spike MS MS %Rec Parameter Units Result Conc. Result % Rec Limits Qualifiers Gil and Grease mg/L NO 40 38.8 j 93 78-114 Date: 04/25/2014 09:48 AM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Page 5 of 11 aceAnalytical ' www.pacelabs.com ( QUALITY CONTROL DATA Project: OUTFALL Pace Project No.: 92197611 QC Batch: WET13O655 Analysis Method: SM 2540D QC Batch Method: SM 2540D Analysis Description: 2540D Total Suspended Solids Associated Lab Samples: 92197611001 METHOD BLANK: 1183321 Associated Lab Samples: 92197611001 Parameter Units Total Suspended Solids mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers N❑ 2.5 04/22/14 20'A4 Pace Anatytical Sary IC85, tnC. 9800 Kincey Ave. Suite 100 huntersville, NC 2807a (704)875-9092 LABORATORY CONTROL SAMPLE: 1183322 Spike LCS LCS % Rec Parameter Units Conc. Result % Rec Limits Qualifiers Total Suspended Solids mglL 250 252 101 80-12 SAMPLE DUPLICATE: 1183323 92197561001 Dup Parameter Units Result Result RPD Qualifiers Total Suspended Solids mg& NO ND SAMPLE DUPLICATE: 1183324 92197643001 Dup Parameter Units Result Result RPD Qualifiers Total Suspended Solids mg/L 10.0 12.6 23 D6 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except m full, Date: 04/25/2014 09:48 AM without the written consent of Pace Analytical Services, Inc,. Page 6 of 11 /55'ce Analytical iwww.p&celab3.com i QUALITY CONTROL DATA Project: OUTFALL Pace Project No.: 92197611 QC Batch: WET130602 Analysis Method: EPA 9040 QC Batch Method: EPA 9040 Analysis Description: 9040 pH Associated Lab Samples: 92197611001 SAMPLE DUPLICATE: 1181329 Parameter Units Sid. Units pH Date: 04/25/2014 09:48 AM 92197495001 Dup Result Result 7.2 7.1 RPD Qualifiers 1 D6,H6 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Pace Analytical Services, Inc. 9800KinceyAve, Suile100 Huntersville, NC 28078 (704 )875-9092 Page 7 of 11 1!;a'ceAna1Xica1" www,pacelabs, cram I I QUALIFIERS Project: OUTFALL Pace Project No.: 92197611 DEFINITIONS DF - Dilution Factor, if feported, represents the factor applied to the reported data due to changes in sample pr the sample aliquot, or moisture content. ND - Not Detected at or above adjusted reporting limit. J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL -Adjusted Method Detection Limit. PRL - Pace Reporting Limit. RL - Reporting Limit. S - Surrogate 1,2-Diphenylhydrazine (8270 listed analyte) decomposes 10 Azubenzene. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery an LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean -Up U - Indicates the compound was analyzed for, but not detected. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270, The each analyte is a combined concentration. Acid preservation may not be appropriate for 2-Chloroethyivinyl ether, Styrene, and Vinyl chloride. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TN -The NELAC Institute. LABORATORIES PASI-A Pace Analytical Services - Asheville PASI-C Pace Analytical Services - Charlotte ANALYTE QUALIFIERS D6 H6 Pace Analytical Services, Inc. 9800 K+nceyAve. Suite 100 Huntersville, NC 28078 (704)875.9092 dilution of RPD values. reported for The relative percent difference (RPD) between the sample and sample duplicate exceeded laboratory control limits. Analysis initiated outside of the 15 minute EPA recommended holding time. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 04/25/2014 09:48 AM without the written consent of Pace Analytical Services, Inc.. Page 8 of 11 I /5a'ce Analytical f wwwpacefabs.com QUALITY CONTROL DATA CROSS REFERENCE TABLE Project: OUTFALL Pace Project No.: 92197611 Pace Analytical Services, Inc, 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875.9092 Analytical Lab ID Sample ID QC Batch Method QC Batch Analytical Method Batch 92197611001 OUTFALL #1 EPA 1664B GCSV117282 92197611001 OUTFALL #1 SM 2540D WET130655 92197611001 OUTFALL #1 EPA 9040 WET130602 Date: 04/25/2014 W48 AM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc,. Page 9 of 11