Loading...
HomeMy WebLinkAboutNCG030683_COMPLETE FILE - HISTORICAL_20170530in STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. /vuc, c)3D (DY 3 DOC TYPE HISTORICAL FILE ❑ MONITORING REPORTS DOC DATE ❑ Do 1 --7 b 5 3 YYYYMMDD 9 , Central Files: APS _ SWP 160-1 5/25/2017 Permit Number NCG030683 Permit Tracking Slip Program Category Status Project Type NPDES SW Active New Project Permit Type Version Permit Classification Metal Fabrication Stormwater Discharge COC 1.00 COC Primary Reviewer Permit Contact Affiliation robert.patterson ME-inl iMEED Coastal SWRuIe MAY 3 0 2017 Permitted Flow CENTRAL FILES DWR SECTION Facility Facility Name Major/Minor Region Draka Elevator Products - Wireway Minor Raleigh Location Address County 6533 Corporation Pkwy Nash Battleboro NC 27809 Owner Facility Contact Affiliation Stephen Berney 2151 N Church St Rocky Mount NC 27804 Owner Name Owner Type Draka Elevator Products Non -Government Owner Affiliation Stephen Bemey 2151 N Church St Dates/Events Rocky Mount NC 27804 Scheduled Orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 5/25/2017 5/19/2017 5/25/2017 5/25/2017 5125=17 10/31/2017 Regulated Activities Requested !Received Events Metal products manufacture + RO staff report received 5/25117 RO staff report requested 5/25117 Outfall 001 Waterbody Name Streamindex Number Current Class Subbasin Giles Branch 28-78-4 C;NSW 03-03-02 Energy. Mineral and Land Resources ENVIRONMENTAL GUAUTV May 25, 2017 Mr. Stephen Berney Draka Elevator Products, Inc. 2151 North Church St. Rocky Mount, NC 27804 ROY COOPER Governor MICHAEL S. REGAN Secretary I'RACY DAVIS Director Subject: General Permit No. NCG030000 Draka Elevator Products - Wireway COC No. NCG030683 Nash County Dear Mr. Berney: In accordance with your application for a discharge permit received on May 19, 2017, we are forwarding herewith the subject certificate of coverage (COC) to discharge under the subject state — NPDES general permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection Agency dated October 15, 2007 (or as subsequently amended). Please take notice that this certificate of coverage is not transferable except upon approval of the Division of Energy, Mineral and Land Resources. The Division of Energy, Mineral and Land Resources may require modification or revocation and reissuance of the certificate of coverage. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Energy, Mineral and Land Resources, the Coastal Area Management Act, or any other federal or local government permit that may be required. Per the requirements of the Tar -Pamlico Riparian Buffer Rule, all stormwater drainage to stream buffers, from portions of this site that have been constructed after January 1, 2000, must meet diffuse flow requirements per 15A NCAC 2B .0259. Diffuse flow requirements are described on the Riparian Buffer Protection Program website: https://deq.iic.�;ov/about/divisions/water- resources/water-resources-permits/wastewater-branch/401-wetlands-buffer-permils1401-riparian- buffer-protection-program If you have any questions concerning this permit, please contact Robert Patterson at (919) 807-6369 or Robert.Pattersonnncdenngov. State oENonh Carolina I Environmental Quality I Energy. Mineral and Land Resources 1612 Mail Service Center 1 512 N. Salisbury tit. I Raleigh, NC 27699 919 707 9200 T Sincerely, for Tracy E. Davis, P.E., CPM, Director Division of Energy, Mineral and Land Resources cc: Raleigh Regional Office Central Files Stormwater Permitting Program Files Slate of North Carolina I Environmental Quality I Energy, Mineral and Land Resources 1612 Mail Service Center 1 512 N. Salisbury St. I Raleigh, NC 27699 919 707 9200 1' STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF ENERGY, MINERAL AND LAND RESOURCES GENERAL PERMIT NO. NCG030000 CERTIFICATE OF COVERAGE No. NCG030683 STORMWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Draka Elevator Products, Inc. is hereby authorized to discharge stormwater from a facility located at Draka Elevator Products - Wireway 6533 Corporation Parkway Battleboro Nash County to receiving waters designated as Giles Branch, a class C; NSW water in the Tar -Pamlico River Basin, in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts 1, I1, 111, IV, V, and VI of General Permit No. NCG030000 as attached. This certificate of coverage shall become effective May 25, 2017, This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day May 25, 2017. for Tracy E. Davis, P.E., Director Division of Energy, Mineral, and Land Resources By the Authority of the Environmental Management Commission LE ' NCDENR NpiTh GROLlYw OCPMSMENI OF EuwreowneM .wo Nil llM+' HCSOUNee's NOTICE OF INTENT Division of Enemy, Mineral and Land Resources Land Quality Section National Pollutant Discharge Elimination System NCG030000 FOR AGENCY USE: ONLY Dale Received Year Monih Day ccn;reatc src � NC r Cl k # ai E n1nk Assigned to National Pollutant Discharge Elimination System application for coverage under General Permit NCG030000: STORMWATER DISCHARGES associated with activities classified as: SIC (Standard Industrial Classification) 335 Rolling, Drawing, and Extruding of Nonferrous Metals SIC 3398 Metal Heat Treating SIC 34 Fabricated Metal Products SIC 35 Industrial and Commercial Machinery SIC 36 Electronic and Other Electrical Equipment SIC 37 Transportation Equipment SIC 38 Measuring, Analyzing, and Controlling Instruments P `-- - For questions, please contact the DEMLR Regional Office for your area. See page 4IW—1 (Please print or type) 1) Mailing address of ownerioperator (address to which all permit correspondence will be mailed): Name Stephen Berney Street Address 2151 North Church Street City Rocky Mount State NC ZIP Code 27804 Telephone No. (252) 972-6010 Fax: (252) 466-6959 2) Location of facility producing discharge: Facility Name Draka Elevator Products - Wireway Facility Contact Stephen Berney Street Address 6533 Corporation Parkway RECEI V CE) City Battleboro State NC ZIP Code 27809 County Nash MAY 19 2017 Telephone No. (252) 972-6010 Fax: (252) 466-6959 Email Stephen.berney@prysmiangroup.com t�f}dIWLANp QIiAUry 3) Physical Location Information: Please provide a narrative description of how to get to the facility (Use street names, state road numbers, and distance and direction from a roadway intersection). Highway 95 to exit 145. Turn Right onto 48S. Turn right onto Corporation Parkway. Arrive at Draka 6533 Corporation Parkway (A copy of a county map or USGS quad sheet with the facility clearly located must be submitted with this application,) 4) Latitude 360 3' 10.8288" Longitude 77" 49' 1.936" 1-1q.043�3 Page 1 of 4 5WU-218-071408 Last revised 712114 NCG030000 N.O.I. 5) This NPDES Permit Application applies to which of the following: ® New or Proposed Facility Date operation is to begin 03/2017 ❑ Existing 6) Standard Industrial Classification: Provide the 4-digit Standard Industrial Classification Code (SIC Code) that describes the primary industrial activity at this facility. SIC Code: 3 4 4 4 7) Provide a brief narrative description of the types of industrial activities and products manufactured at this facility: Sheet steel arrives by trailer truck, unloaded and stored indoors. Bending, press, punch and resistance welding operations converting sheets into Wireway trough parts. Parts loaded onto trailer trucks. Material handling — propane powered forklifts. 8) Discharge points ! Receiving waters: How many discharge points (ditches, pipes, channels, etc.) convey stormwater from the property? 1 What is the name of the body or bodies of water (creek, stream, river, lake, etc.) that the facility stormwater discharges end up in? Unnamed tributary of Swift Creek Receiving water classification: C:NSW Is this a 303(d) listed stream? NO Has a TMDL been approved for this watershed? NO If the site stormwater discharges to a separate storm sewer system, name the operator of the separate storm sewer system (e.g. City of Raleigh municipal storm sewer). NA 9) Does this facility have any other NPDES permits? N No ❑ Yes If yes, list the permit numbers for all current NPDES permits for this facility: 10) Does this facility have any Non -Discharge permits (ex: recycle permit)? R No ❑ Yes If yes, list the permit numbers for all current Non -Discharge permits for this facility: 11) Does this facility employ any best management practices for stormwater control? ❑ No ® Yes (Show any structural BMPs on the site diagram.) If yes, please briefly describe: o4 D 12) Does this facility have a Stormwater Pollution Prevention Plan? ❑ No W Yes If yes, when was it implemented? 03/2017 13) Are vehicle maintenance activities occurring at this facility? IN No ❑ Yes 14) Hazardous Waste: a) Is this facility a Hazardous Waste Treatment, Storage, or Disposal Facility? Page 2 of 4 SWU-218.071408 Last revised 712114 NCG030000 N.O.I. 9 No ❑ Yes b) Is this facility a Small Quantity Generator (less than 1000 kg. of hazardous waste generated per month) of hazardous waste? M No ❑ Yes c) Is this facility a Large Quantity Generator (1000 kg, or more of hazardous waste generated per month) of hazardous waste? ® No ❑ Yes d) Is hazardous waste stored in the 100-year flood plain? IR No ❑ Yes If yes, include information to demonstrate protection from flooding. e) If you answered yes to questions b. or c., please provide the following information: Type(s) of waste: How is material stored: Where is material stored: How many disposal shipments per year: Name of transport 1 disposal vendor: Vendor address: 15) Certification: North Carolina General Statute 143-215.6E (i) provides that: Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan, or other document filed or required to be maintained under this Article or a rule implementing this Article; or who knowingly makes a false statement of a material fact in a rulemaking proceeding or contested case under this Article; or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under this Article or rules of the Commission implementing this Article shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed ten thousand dollars ($10,000). I hereby request coverage under the referenced General Permit. I understand that coverage under this permit will constitute the permit requirements for the discharge(s) and is enforceable in the same manner as an individual permit. I certify that I am familiar with the information contained in this application and that to the best of my knowledge and belief such information is true, complete, and accurate. Printed Name of Person Signing; Stephen Berney Title: Health, Safety & Environmental Engineer_ (Signature of Applicant) 05102/2017 (Date Signed) This Notice of Intent must be accompanied by a check or money order for $100.00, made payable to: NCDENR Page 3 of 4 SWU-218-071408 Last revised 7/2/14 NCG030000 N.O.I. Final Checklist This application will be returned as incomplete unless all of the following items have been included: ❑ Check for $100 made payable to NCDE.NR. _'31 This completed application and all supporting documents. A site diagram showing, at a minimum, (existing or proposed): '(a) outline of drainage areas, �b) stormwater management structures, f c) location of stormwater outfalls corresponding to the drainage areas, (d) runoff conveyance features,- e) areas where materials are stored, If) impervious areas, & site property lines, Copy of county map or USGS quad sheet with the location of the facility clearly marked on the map. Mail the entire package to: Stormwater Permitting Unit Program Division of Energy, Mineral and Land Resources 1612 Mail Service Center Raleigh, North Carolina 27699-1612 Note The submission of this document does not guarantee coverage under the General Permit. For questions, please contact the DEMLR Regional Office for your area. DEIVILR Regional Office Contact Information: Asheville Office ...... (828) 296-4500 Fayetteville Office ... (910) 433-3300 Mooresville Office ... (704) 663-1699 Raleigh Office ........ (919) 791-4200 Washington Office ... (252) 946-6481 Wilmington Office ... (910) 796-7215 Winston-Salem ...... (336) 771-5000 Central Office ......... (919) 807-6300 Page 4 of 4 SWU-218.071408 Last revised712114 Prysmian Group CERTIFIED MAIL, 7004 2890 0002 9227 6705 Stormwater Permitting Unit Program Division of Energy, Mineral and Land Resources 1612 Mail Service Center Raleigh, North Carolina 27699-1612 Draka Elevator Products 2151 North Church Street Rocky Mount, North Carolina 27804 Re: Notice of intent NPDES application for coverage under NCG030000 Date: May 3, 2017 PRYSMIAN Draka Draka Elevator has completed and enclosed an NPDES application for coverage under General Permit NCG030000 for property address of 6533 Corporation Parkway, Battleboro NC. The following documents are attached to satisfy the application requirements: 1, Completed Notice of Intent 2, Check for $100 payable to NCDENR 3. Site Diagram indicating drainage, outfalls, conveyances, storage areas and property lines. 4. Topographical map depicting site location Please direct any questions regarding this application to Stephen Berney (252) 822-2540. Sincerely, Stephen Berney HSE Engineer Draka Elevator Products RECEIVED MAY 19 2017 WA"F '°ARM f'iTJNr, Telephone E-mail Draka Etevator 252-446-8113 drakaep-info@draka.com 2151 North Church Street Fax Intenef Rocky Mount, NC 27804 USA 252-446-6959 www.prysrniangroup.com NCDENR 'Division of Water Qualityi4 1617 Mail Service Center Raleigh NC 27699-1617 rrysmlan Croup Document Your document Date Deductions Gross amount N r 1900018954 NCG030000 Sum total 05/08/2017 0.00 100.00 0.00 100.00 p 2017 J 6,0 �3���� o• r r• ■ -r r ■ ■ { 1 Prysmian Drake Elevator Products CITIBANK, N.A. 62-20 CHECK NO. 069229 Group 2151 N. Church Street One Penn's Way f Rocky Mount, NC )27804 - New, Castle, DE 19720 DATE 05/11/2017 r *** ONE HUNDRED USD*** ***********100.D0*USD-' VOID AFTER 120 DAYS PAY TO THE ORD,ER'� OF NCDENR r .1617,Mai1 Service Centex Raleigh NC 27699-1617 r r,• : 1 1 1 '•�h y tari"• f � J`�' caw. Y (( l rf v Y 1 1 Rock � 'r 1 sr•� r � • JIMY YII r P C; • J l n � � ►s� EI dry • MCA Draka Elevator Products - ♦ Wireway ♦ t 1 x 4& # # 48 A% tom" �.�I VVV r' t•� ,fir •�• ~ _ / �) yaw I/ .I► i `. YYY O \ i IL wrwi �.+w ..arm -vA� � � � ••`...fir.. �`���� �•_/ Now q r Seib �4 NCG030683 N W E W­ I Map Scale 1: 24, 000 Draka Elevator Products, Inc. Wireway Latitude: 360 03' 11" N Longitude: 770 49' 02" W County: Nash Receiving Stream: Giles Branch Stream Class: C; NSW Stream Index: 28-78-4 (Tar -Pamlico River Basin) . ri1�� ran y., Facility Location cs� , (4t cik �o �JManns � W —��• te`in Q RD P(tl� FQ N ¢ A iso - Gold -" Rock �- - - - 48 . •.. "]� _� v - -... - ... .fir - _ - rl�� _ N J v� 1lO 4KN� 4 Braswell Cem 4 p ,s, .� SI7E y 1� o f50 0 i o - •TSO,, t Duke RED DSO �'aTjfsz tT� 4 r Cr Z. Zl- c. 6533 Comor_jon,y ML > r Zn �: T` goofed shed j'. _ — — for dumpsters 5tormwater } �, retention 16 *� ,r y` r A i I WEI IN U IV c rt D r i- � � tj ' I v' I t I _ — -_-_-_-__- 17, �111 7m 1171 ill, _r _ — _ — _ — _ — _ — _ — _ — -- T "K'- Anaa®� 0AK DRAKA ELEVATOR a, , w COLEY LLIER RCHITECTS WHITAKER INDUSTRIAL PARK r NASH COUNTY, NORTH GAROLINA �w G iPra�n rFf+' .�