Loading...
HomeMy WebLinkAboutNCG030647_COMPLETE FILE - HISTORICAL_20190506M �-o, STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT N0. Iv CC U -2 DOC TYPE -�YHISTORICALPILE ❑ MONITORING REPORTS DOC DATE ❑ � b' � D 5 D (9 YYYYMMDD Subject: _,�' f 2: 1 ) � 9 10, May 1, 2019 NC DENR Division of Water Quality Surface Water Protection Section !; 610 East Center Ave. Mooresville, NC 28115 a> d� G� Representative Outfall Status (ROS) Request Greenheck Fan Corporation COC: NCG030647 To Whom It May Concern: On behalf of Greenheck Fan Corporation, please find the enclosed "Representative Outfall Status (ROS) Request Form," two (2) copies of the facility site map, and a summary of monitoring results table to request ROS analytical sampling at Outfall # 1 at the property. This request is being submitted after on -site review and discussions with Holliday Keen, an Environmental Senior Specialist at DEMLR. Holliday would be familiar with site operations and history of the site. The facility is regulated under General Permit No. NCG030000 "Metal Fabrication." The facility is additionally regulated by Permit No. SWO03 under the City of Shelby's Phase II Stormwater Ordinance. Three (3) drainage areas with corresponding outfalls are present at the property (see enclosed site maps). To comply with City of Shelby's Phase II Stormwater Ordinance, Drainage Area # 1 was designed as high -density and runoff is controlled and treated by a wet detention basin. Drainage areas #2 and #3 were designed as low -density. No TMDLs or impairments are noted for the associated receiving waterbody beyond a statewide TMDL for mercury contaminated fish tissue. All potential industrial stormwater exposures are contained outside the southern portion of the facility and within Drainage Area # 1 as indicated on the enclosed site maps. Potential exposures within Drainage Area # 1 include: 1) Scrap metal dumpsters, 2) Wood pallets, 3) Laser dust dumpster, 4) Lumber, 5) Empty drums, 6) Metal parts, 7) Loading docks, and 8) Garbage dumpsters. Drainage Areas #2 and #3 serve only as employee parking and are ancillary to associated industrial activity. The parking area is paved and surrounded by manicured grass. We are requesting ROS for Outfall # 1 (Drainage Area # 1) only since the vast majority of industrial activity occurs within this drainage area and would be representative of the true industrial stormwater exposures at the site. i t � I i 0 RE[ Engine g Inc. P:\6066-6099\6016-Greenheck\Nonh Camlfna\Stormwater\Shelby Storm Wi ter\OEO CorroapOndence\Req for RCp O lfall Sum-\ i I6NCROS.docx I 1I {ri ALIT NCDENR Division of Water Quality / Surface Water Protection National Pollutant Discharge Elimination System REPRESENTATIVE OUTFALL STATUS (ROS) REQUEST FORM FOR AGENCY USE ONLY Date Received Year Month Da if a facility is required to sample multiple discharge locations with very similar stormwater discharges, the permittee may petition the Director for Representative Outfall Status (ROS). DWQ may grant Representative Outfall Status if stormwater discharges from a single outfall are representative of discharges from multiple outfalls. Approved ROS will reduce the number of outfalls where analytical sampling requirements apply. If Representative Outfall Status is granted, ALL outfalls are still subject to the gualitatfve monitoring requirements of the facility's permit —unless otherwise allowed by the permit (such as NCGO20000) and DWQ approval. The approval letter from DWQ must be kept on site with the facility's Stormwater Pollution Prevention Plan. The facility must notify DWQ in writing if any changes affect representative status. 1) a For questions, please contact the DWQ Regional Office for your area (see page 3). (Please print or type) Enter the permit number to which this ROS request applies l Individual Permit (or) Certificate of Coverage N I C I 5 �- N C G 0 3 0 ii 4 7 Facility Information:; Owner/Facility Name Greenheck Fan Corporation: c� V'A' (P Facility Contact Jason Powell 6 co 'A Street Address 2000 Partnership Drive °'- o City Shelby O-W State NC ZIP Code 28150 County Cleveland `� E-mail Address jason.powell@greenheck.com Telephone No. (704) 476-3743 Fax: 3) List the representative outfalls) information (attach additional sheets if necessary): Outfall(s) 1 is representative of Outfall(s) 2 Outfalls' drainage areas have the same or similar activities? ❑ Yes X No Outfalls' drainage areas contain the same or similar materials? ❑ Yes X No Outfalls have similar monitoring results? X Yes ❑ No ❑ No data* Outfall(s) is representative of Outfall(s) Outfalls' drainage areas have the same or similar activities? ❑ Yes X No Outfalls' drainage areas contain the same or similar materials? ❑ Yes X No Outfalls have similar monitoring results? X Yes ❑ No o No data* Outfall(s) is representative of Outfall(s) Outfalls' drainage areas have the same or similar activities? ❑ Yes ❑ No Outfalls' drainage areas contain the same or similar materials? ❑ Yes ❑ No Outfalls have similar monitoring results? ❑ Yes ❑ No ❑ No data* *Non-compliance with analytical monitoring prior to this request may prevent ROS approval. Specific Page 1 of 3 SW U-ROS-2009 Last revised 12/30/2009 A summary of monitoring results table is enclosed. Historical sampling at Outfalls # 1 and #2 have been within permitted benchmark values. One (1 ) exceedance of the benchmark for zinc occurred at Outfall #3 on February 281h, 2018 during the first annual sampling event. It is unknown why zinc was present at levels above the benchmark at this outfall since this drainage area is not associated with storage of industrial materials and no material handling operations occur in the area. A potential explanation may be the third -party laboratory may have collected the sample at the wrong location. As seen in the attached site map, if the sample was collected downstream of the outlet pipe it would not be representative of the stormwater leaving the facility parking area. Collecting a sample beyond the outlet pipe would include runoff from off -site properties and roadways located north of the facility. In summary, we are formally requesting analytical sampling requirements for Outfall # 1 only. Outfall # 1 represents stormwater runoff from all industrial activities at the site. We request that analytical sampling is waived for Outfalls #2 and #3 since these areas of the property are ancillary to industrial activity and serve as employee parking. All other permit requirements would apply to Outfalls #2 and #3. Please feel free to contact me with any questions at (715) 675-9784. A copy of this request has also been emailed to Suzanne McCoy at suzanne.mccoyencdenr.gov as directed by your website. Sincerely, REI Engineering, Inc. Jason Christopherson, M.S. Environmental & Safety Consultant Enclosures ORE] Engtneenng Inc. - 2 - P:\6000-6099\6016-Creenheck\North CarolLn,\Stortmaater\Shelhy Storm Water\CEO Correspondence\Req for Rep Oulfdll Status\6016NCROS.docx Representative Outfall Status Request circumstances will be considered by the Regional Office responsible for review. 4) Detailed explanation about why the outfalls above should be granted Representative Status: (Or, attach a letter or narrative to discuss this information.) For example, describe how activities and/or materials are similar. Please see attached cover letter S) Certification: North Carolina General Statute 143-215.6 B(i) provides that: Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan, or other document filed or required to be maintained under this Article or a rule implementing this Article; or who knowingly makes a false statement of a material fact in a rulemaking proceeding or contested case under this Article; or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under this Article or rules of the [Environmental Management] Commission implementing this Article shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed ten thousand dollars ($10,000). I hereby request Representative Outfall Status for my NPDES Permit. I understand that ALL outfalls are still subject to the qualitative monitoring requirements of the permit, unless otherwise allowed by the permit and regional office approval. I must notify DWQ in writing if any changes to the facility or its operations take place after ROS is granted that may affect this status. If ROS no longer applies, I understand I must resume monitoring of all outfalls as specified in my NPDES permit. I certify that I am familiar with the information contained in this application and that to the best of my knowledge and belief such information is true, complete, and accurate. ning: Jason Powell Title:JTant Ma Of 5 /1// (Date Signed) Plea note: This applii;ation for Representative Outfall Status is subject to approval by the N NR Regional Office. The Regional Office may inspect your facility for compliance with the conditions of the permit prior to that approval. Final Checklist for ROS Request This application should include the following items: X This completed form. X Letter or narrative elaborating on the reasons why specified outfalls should be granted representative status, unless all information can be included in Question 4. X Two (2) copies of a site map of the facility with the location of all outfalls clearly marked, including the drainage areas, industrial activities, and raw materials/finished products within each drainage area. X Summary of results from monitoring conducted at the outfalls listed in Question 3. X Any other supporting documentation. Mail the entire package to: NC DENR Division of Water Quality Surface Water Protection Section at the appropriate Regional Office (See map and addresses below) Page 2 of 3 SWU-ROS-2009 Last revised 1213012009 Representative Outfall Status Request Notes The submission of this document does not guarantee Representative outfall Status (ROS) will be granted as requested. Analytical monitoring as per your current permit must be continued, at all outfalls, until written approval of this request is granted by DWQ. Non-compliance with analytical monitoring prior to this request may prevent ROS approval. Specific circumstances will be considered by the Regional Office responsible for review. For questions, please contact the DWQ Regional Office for your area. Asheville Regional Office 2090 U.S. Highway 70 Washington Regional Office Swannanoa, NC 28778 943 Washington Square Mail Washington, NC 27889 Phone (828) 296-4500 FAX (828) 299-7043 Phone (252) 946-6481 FAX (252) 975-3716 Fayettevilie Regional Office Systel Building, Wilmington Regional Office 225 Green St., Suite 714 127 Cardinal Drive Extension Fayetteville, NC 28301-5094 Wilmington, NC 28405 Phone (910) 433-3300 Phone (910) 796-7215 FAX 9101486-0707 FAX (910) 350-2004 Mooresville Regional Office Winston-Salem Regional Office 610 East Center Ave. 585 Waughtown Street Mooresville, NC 28115 Winston-Salem, NC 27107 Phone (336) 771-5000 Phone (704) 663-1699 Water Quality Main FAX (336) 771-4630 FAX (704) 663-6040 Central Office Raleigh Regional Office 1617 Mail Service Center 1628 Mail Service Center Raleigh, NC 27699-1617 Raleigh, NC 27699-1628 Phone (919) 807-6300 Phone (919) 791-4200 FAX (919) 807-6494 FAX (919) 571-4718 Page 3 of 3 SWU-ROS-2009 Last revised 12/30/2009 DRAINAGEAREA#1 DRAINAGEAREA#2 DRAINAGEAREA#3 _ c _ PERVIOUS(S.F.) 177,403 27,659 21,141 NOW le 11 75 — , _. F IMPERVIOUS (S.F.j 198,782 23,012 51.277 OUTFALL #2 \ f 4 rwosl sb 3,297 J TOTAL(S.F.) 376,185 50,671 72,418 f� - -_ —• - - -- 4�7 DRAINAGE AREA #2DRAINAGE I r fa��.,ra; - �`" -^�•` =� 5 ° � ..YC[_ i [ - � .....-a••s...r_-,rr[/ �� � , f I _ - A #� AREr- �w0sl sa' zc sa r = „I iIIf1 rI1. .�, ��t /yr / k i .l•� I 1 16' I'I.I.I_I { �..I ° 111 ["u 1 I I I I I11�� —. _ - rt`R �. :;,a \•' a <:�% - -- - UY . %� 1. - t - ,.tea: ' I �.I•� F L. ------- J. �t bi } f •3 OUTFALL #3 DRAINAGE "A AREA #I ill �� .''71 .�� .Ih'�ft�_ � � � c«.ss I I, ��'i�3 i�ll� -_-- .� .3 ��•\ 1 I OI I -1 I lllI N II I, LIT I I I ' � �d I� cA.'.'.'F• � - c � J EXPANSION l ,��, �) 1„^ _• M I' 1 , t8f1,000 SF CRYO TANKS '' u I IIII ■ l I i I I r�', -- i.' LI i �I_.�� I'��}± �, - -�F ....J _�r• I �` i / ! I ' � +-. ! I I� I J•'.I_J ��_._ f. I �_ , e,�l � ! ` .r: ' +� rr sss I _ �, // " ` __ . `r--- - -r I r \r�+,+r , i � f !•� i �,a _ '• �;,, - / '� _ _ r-i} 1 - --_-J --- --- ---- - - - - -` _0----%� %----- �` --��i'ffj, !`��-__--'__-- �c,'%:����,;r",���� e5lo'5s'E �'-_ '� :.� •,�; �. --� - f,`•l .. w METAL D SCRAP UMPSTERS,, in5r ;3•' ,.,_.r _- _- Il == `` ' / 1 ; ', �_.NRET PALLETS, LASER DUST DUMPSTE i';rcT WMBER, EMPTY DRUMS, METAL ' EMGWEERWCw 6UAYEYBVfi PARTS, LOADING DOCKS, AND w081. 36' 22.26' y '" - M cuR: 2 SITE p REFUSE DUMPSTERS. -- OUTFACE #I�' ^y'- _ PH0Jf'CT No. DRAWN Q �D,IaD r —5— cDLm lON9L T— Dd tD -U-1-1 ❑ FOR REFERENCE ONLY RCf Englrrerrhq, iNc.1 6015 VC'd SCALE O SC ,OQ l l _ I _ I I J DRAINAGEAREA#1 DRAINAGEAREA#2 DRAINAGEAREAtt3 sjp �y PERVIOUS {S.F.) 177,403 t r IMPERVIOUS (S.F.) 198,782 OUTFALL #2- wosl 36R 97 1ui4IIT —�'Q TOTAL;S.F.j 376,185 DRAINAGE -- _ - - �� 11� _ %' AREA #2 /, I I I ! I I `III I irI"I 1 I I DRAINAGE ,� - = -_ _ _ • j/, •. ., NO35' 16 II 67 a =_ i • / r r AREA #3 Y�// woel• sa z+ sa _ _ --_ _ -_ I IIIii^IIIII �� ` At A OUTFALL #3 DRAINAGE t r AREA #f �i- - -- -- 5 .[<� �= � .'�: � ' � � I � � �.,•yl' � ; <yI g•a I II III i i i, i1 ' �_ �/ •V='11 ' II L+�f 11r • T�1 �� i t ,, J I , � ; I II�;I;;k;���I�; ---- I - - - - -- n' - FFF ;• � >•��� �. ----------'t li 4 ICI II�I� �;.. EycrnNs[oN r I ;rfiid t00 80,0SF rl. i _ i I � 27,659 21,142 23,012 51,277 50,673 72,418 °- i CRYO TANKS 1. ss I r�l�riirlirl My '�, %' •\ 1`I Ta3-- ---- I � ti � .i i •..i T i i• f<i � i I. i �' ,� >t� ' - 11-1t-1 1:_J'1•-1�,1� �' __ ��K-_�__ -� — nR •� •-!- �F�^ , ,,, �, �,:; �`r'''`,I I „'I r �W=, '�;t . Ft 5, •7 •w r `1 , / 5/ ` � /__°w ; Y.S-Y 'e, --ll-_ �7: I. -;; •"• e `r 1` , i i r i m�' '�.f� w ' `�.-.o L > ll., '..� / � f i'� `�'" 5`� -, � �1 , i is � i oar ` •° ` - //// f I III ff —t�l�' ,. �F a.".' //j/�/ter'{I'�,'' l�' , ! ��i�F' , , • '�.•. - ' �/i // S sb'Ia'j9"E ••-.... �• _ ;,�� �.:- -_--- -_ _'1`•- li; `,.`.� -,. ��.,� -_ _ =-_-_ =___ '��� '� e�;;•`��"ani "� ��i Ir rJ�G�lidr �� r ' SCRAP METAL DUMPSTERS,J �9 e� —•• y-- _ <��' / / k, ,' �Lp �9i rrq REI PALLETS, LASER DUST pUMPSTER, LUMBER, EMPTY DRUMS. METAL y•�.� al SLYWEVWG n. , 0. , o NOSS• is as.00 °�.W, •_: y PARTS, LOADING DOCKS, AND �t wool, sa' zz.za q ' ' I ,i `- ;'.�ry.��?�%r� FIGURE - SIIE VIAP REFUSE DUMPSTERS. - I OUTFALL #I E;j+i . r1 ?RWLCT tiro. DRAVIN ;: eaiein>: �a�ri,:e •�a-:me n. na..rsa.w Eon: �ou5urwc. o.reo ro.ee,.ou _ FOR REFERENCE- ONLY 'r?fr £nq:neering. rh'C. 5015 MC' 'N Jrf/ /!- SCALE ` 0 5- —07 1 Summary of Monitoring Results Greenheck Fan Corporation 2000 Partnership Drive Shelby, NC 28150 Certificate of Coverage: NCG030647 Benchmarks for Permit No. NCG030000 Total Rainfall in ( ) Total Suspended Solids (mg/L) pH, Standard Units Total Copper m /L ( g ) Total Lead (mg/L) Total Zinc (mg/L) Non -Polar O&G /L (m <3 ) Total Toxic Organics /L (m g ) Outfall Date Sample Collected N/A 100 6.0-9.0 0.010 0.075 0.126 15 1 Outfall#1 2/28/2018 0.22 22 6.47 1 <0.0050* <0.0010* 0.032 <4.5* N/A 10/11/2018 1.28 6.1 6.2 <0.0050* <0.0010* <0.010* <4.3* N/A Outfall42 2/28/2018 0.22 58 6.39 0.0056 0.0016 0.027 <4.3* N/A 10/11/2018 1.28 7.5 6.4 <0.0050* <0A010* <0.010* <5.1* N/A Outfall #3 2/28/2018 0.22 26 6.86 0.0093 0.0016 0.160 <4.3* N/A 10/11/20181 1.28 80 6.4 <0.0050* <0.00f0* 1 0.016 1 <4.5* N/A * Below the Limit of Qaantitation (LOQ)