Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NCG030070_MONITORING INFO_20190204
42 0 STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. /v p3no7 u DOC TYPE ❑HISTORICAL FILE MONITORING REPORTS DOC DATE o Jul 0 UJ o y YYYYMMDD Al 1! It F%IP IP January 28, 2020 Central files Division of Water Resources 1617 Mail Service Center Raleigh, NC 27699-1617 Re: ABB Motors and Mechanical (Baldor Electric) General Permit No. NCG0030070 ABB Motors and Mechanical 70 Reems Creek Rd Weaverville, NC 28787 FEB 0 4 20 t9 CEN'TFzgL FILES DVWI� SECT101j Please find enclosed the stormwater discharge monitoring reports for November and December 2019. In November we performed the second semi-annual sampling. We were unable to collect a representative sample in December. The November results for conveyance point G exceed the benchmarks for zinc, copper and `ss, This elevates us to Tier II status for copper and zinc. We are currently researching possible causes for these exceedances. We remain in Tier II status for copper and zinc at conveyance point D. No significant process sources of zinc or copper have been identified at our facility. We continue to believe that the major contributors are infrastructure sources. Please contact me with operational or compliance issues. Otherwise contact Dan March of Pisgah Environmental Services at 828-768-3335 or via email at Pisgah -air cg t.edu if you have questions or comments concerning technical aspects of this report. Sincer ly. X�� A4V__t/_ Gary Massey Safety Coordinator ABB Motors and Mechanical 828-645-1718 gary.masse a,us.abb.com Page 1 of 1 r� Stormwater Discharge Monitoring Report for North Carolina Division of Energy, Mineral and L nd esources General Permit No. NCG030000 Date submitted l Z� �Lo CERTIFICATE OF COVERAGE NO. NCG03 0 0 7 0 FACILITY NAME Ass Motors and Mechanical COUNTY Buncombe PERSON COLLECTING SAMPLES Dan March, Pisgah Environmental LABORATORY Pace analytical Lab Cert. # 40 Comments on sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2019 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or El Monthly' (month) CDISCHARGING TO CLASS ❑ORW ❑HQW ■❑Trout ❑PNA CU ��� l.� ED []zero -flow ❑Water supply ❑SA FEB 0-4 2Q19 ❑other Lhi-i AL FILEC PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 DWR SECTION © No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches' Total Suspended Solids pH, standard units Total Copper Total Lead Total Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organicss Benchmarks _ - 100 mg/L or 50 mg/O 6.0 — 9.0 0.010 mg/L 0.075 mg/L 0.126 mg/L 15 mg/L 1 mg/L Parameter Code - 46529 C0530 00400 01119 01051 01094 00552 78141 No Discharge ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 'The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. ° See General Permit, Section B, Table 1 to identify the especially sensitive receiving water classifications where the more protective benchmark applies. s Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2018-05/31/2021 5WU-245, last revised 11/1/2018 Page 1 of 3 f Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Dale Spivey Name (Print name) Plant Manager T e (Print title) v4 I-Z�-� Signature Date Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mR/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: if you rep art a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, inches' New Motor Oil or Hydraulic Oil Usage Non -Polar O&G/ Total Petroleum Hydrocarbons Total Suspended Solids Benchmarks - - 15 mg/L 100 mg/L or 50 mg/O Parameter Code - 46529 NCOIL 00552 C0530 Footnotes from Part A also apply to Part B Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Permit Date: 11/1/2018-05/31/2021 SWU-245, last revised 11/1/2018 Page 2 of 3 FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME QUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART It SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANYONE QUTFALL? YES 0 NO ❑ 1F YES, HAVE YOU CONTACTED THE DEMLR REGIONAL OFFICE? YES [] NO ❑ REGIONAL OFFICE CONTACT NAME: StanieyAiken Mail an original copy of this DMR including all "No Discharge" reports, within 30 days o recei t of the lab results or at end of monitoring period in the case o "No Discharge" re orts to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." Signature of Permittee l - 28 -Zd Date Permit Date: 11/1/2018-05/31/2021 SWU-245, last revised 11/1/2018 Page 3 of 3 \,rr Stormwater Discharge Monitoring Report for North Carolina Division of Energy, Mineral and Land Resources General Permit No. NCG030000 Date submitted 01/28/2020 CERTIFICATE OF COVERAGE NO. NCG03 0 0 7 0 FACILITY NAME ASS Motors and Mechanical COUNTY Buncombe PERSON COLLECTING SAMPLES Dan March, Pisgah Envi LABORATORY Pace Anatytical Lab Cert. ## 40 Comments on sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2019 SAMPLE PERIOD ❑ Jan -June Q July -Dec or ❑ Monthly' (month) DISCHARGING TO CLASS ❑ORW ❑HQW ME Trout ❑PNA ❑Zero -flow ❑Water Supply ❑SA ❑Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 --> ❑ No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches' Total Suspended Solids pStandard units Total Copper Total lead Total Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons TotalToxic Organicnits Benchmarks - - 100 mg/L or 50 mg/L° 6.0 -- 9.0 0.010 mg/L 0.075 mg/L 0.126 mg/L 15 mg/L 1 mg/L Parameter Code - 46529 C0530 00400 01119 01051 01094 00552 78141 B 11/23/19 .22 12.0 6.2 <.005 <.005 .151 <4.8 C 11/23/19 .22 14.8 6.4 .0076 ..0064 .0994 <4.8 D 11/23/19 22 2.8 6.5 <.005 .0078 .0850 <4.8 E 11/23/19 1 .22 5.7 6.4 <.005 .0051 .0515 <4.8 "Continued" ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 'The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. R See General Permit, Section B, Table 1 to identify the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Fffluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469,12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/l/2018-05/31/2021 SWU-245, last revised 11/1/2018 Page 1 of 3 Stormwater Discharge Monitoring Report for North Carolina Division of Energy, Mineral and Land Resources General Permit No. NCG030000 Date submitted 01/2812020 CERTIFICATE OF COVERAGE NO. NCG03 0 0 7 0 FACILITY NAME ABB Motors and Mechanical COUNTY Buncombe PERSON COLLECTING SAMPLES Dan March, Pisgah Envi LABORATORY Pace Analytical Lab Cert. # 40 Comments on sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2019 SAMPLE PERIOD ❑ Jan -June 0 July -Dec or ❑ Monthly'(month) DISCHARGING TO CLASS ❑ORW ❑HQW QTrout ❑PNA ❑Zero -flow ❑Water supply ❑SA []Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 --1 No discharge this period?2 Outfaill No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches; Total Suspended Solids pH, Standard units Total Copper Total Lead Total Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics' Benchmarks _ - 100 mg/L or 50 mg/O 6.0 - 9.0 0.010 mg/L 0.075 mg/L 0.126 mg/L 15 mg/L 1 mg/L Parameter Code - 46529 C0530 00400 01119 01051 01094 00552 78141 F 11/23/19 .22 <2.5 6.4 <.005 <.005 .0297 <4.8 G 11/23/19 .22 68.7 6.2 .0231 .0255 .383 <4.8 1 11/23/19 .22 <2.7 6.3 <.005 <.005 .0548 <4.8 "Continued" ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 'For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 'The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. ' See General Permit, Section B, Table 1 to identify the especially sensitive receiving water classifications where the more protective benchmark applies. s Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2018-05/31/2021 SWU-245, last revised 11/1/2018 Page A of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Dale Spivey Name (Print name) Plant Manager (Print title) z ) I-z��~Zo Signature Date Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 New Motor Oil or Hydraulic Oil Usage Non -Polar O&G/ Total Petroleum Hydrocarbons Total Suspended Solids Benchmarks - - - 15 mg/L 100 mg/L or 50 mg/0 Parameter Code - 46529 NCOIL 00552 C0530 Footnotes from Part A also apply to Part B Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Permit Date: 11/1/2018-05/31/2021 SWU-245, last revised 11/1/2018 Page 2 of 3 FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS, SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES CJ NO ❑ IF YES, HAVE YOU CONTACTED THE DEMLR REGIONAL OFFICE? YES M NO ❑ REGIONAL OFFICE CONTACT NAME: Stanley Aiken Mail an original copy of this DMR, includina all "No Discharae" reports, within 30 days of receipt of the lab results for at end of monitorinq period in the case o "No Dischar e" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." Signature of Permittee Permit Date: 11/1/2018-05/31/2021 Date SWU-245, last revised 11/1/2018 Page 3 of 3