Loading...
HomeMy WebLinkAboutNCG020052_COMPLETE FILE - HISTORICAL_200806252p,,, STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. a) d (iSoC DOC TYPE X HISTORICAL FILE ❑ MONITORING REPORTS DOC DATE ❑ � b YYYYMMDD jFwd: [Fwi [Fwd: Hanson Aggregate Crabtree Quarry] II Subject: [1=wd: [Fwd: Re: [Fwd: Hanson Aggregate Crabtree Quarry]]] From: Judy Garrett <@dy.garrett@ncmail.net> Date: Wed, 25 Jun 2008 09,27:41 -0400 To: Ken Pickle <Ken.Pickle@ncmail.net> ------- Original Message-------- Subject:[Fwd: Re: [Fwd: Hanson Aggregate Crabtree Quarry]] Date: Wed, 13 Feb 2008 1 1:49:17 -0500 From:Judy Garrett <iudy.garrettCr?ncmail.nct> To:Ken Pickle <Ken.Picklc((i),ncmail.net> CC:Danny Smith <Danny.Smith (,ncmail,net>, Shelton Sullivan <Shelton.Sullivan u,ncmail.net> Hi Ken, 011� Here are the comments from Barry. We also recommend that you also run the plans by Shelton Sullivan since we have a pending enforcern&se concerning this facility. Danny said that in the cover letter with the ATC we should tell Hanson that we will reinspect the reparian buffer near the creek to determine if additional plantings may be necessary, if the vegetation was impacted. He said either he or Shelton can help you with the language for this. Judy Garrett -------- Original Message-------- Subject:Re: [Fwd: Hanson Aggregate Crabtree Quarry] Date:Wed, 13 Feb 2008 11:29:36 -0500 From:Barry Herzberg <barry.herzberg a,ncmail.net> To:Judy Garrett <judy.garrett a,ncmail.net> References:<47131 F7B5.1010009 a,ncmail.net> Judy, 3 This looks okay to me, but I'd ask them why the ERMA linerisnot anchored at the top of the berm. I think that standard construction practice is to anchor top and bottom to prevent liner slippage. I put the drawings back in your mailbox. Barry Barry Herzberg Environmental Engineer NCDENR - DWQ Raleigh Regional Office Voice 919-791-4249 Fax 919-788-7159 Judy Garrett wrote: I of 3 7/24/2008 2:55 I'M IFwd: IFwctt ;c: IFNvd: Hanson Aggregate Crabtree Quarry]]] • / I Barry, What do you think about this. This was an existing process and stormwater treatment basin that is under the 100 year flood. Judy -------- Original Message -------- Subject: Hanson Aggregate Crabtree Quarry Date: Tue, 12 Feb 2008 08:24:22 -0500 From: Ken Pickle <ken.pickle rc,ne1nall.net> To: Judy Garrett <Judy.Garrett a,ncmail.net> CC: Danny Smith <Dartny.Smith ei,nctnail.net>, Bradley Bennett <Bradley.Bennett u,ncmad.net> 1-li Judy, Re: NOV for Hanson Crabtree Quarry, NCG020052 a) I received the revised drawings for the Hanson holding pond yesterday. They have addressed all my concerns from an additional information request, and I'm ok with issuing an ATC based on the talcs I received October 24, 2007, and on the revised drawings I received yesterday. b) RRO's July 6, 2007, NOV letter lists the required response from Hanson as, "3. Your staff has indicated that the company intends to build a concrete basin to replace the current earthen basin at the rock crusher. All additional wastewater treatement facilities and equipment must receive an Authorization to Construct prior to installation as outlined in Part II Secretion A of the permit. Please call Ken Pickle at (919) 733-5083 extension 584 concerning questions about obtaining Authorization to Construct." Also, item 2 of the required responses in the NOV letter requires float controls and telemetry alarms. c) I have met with those folks, had a couple of phone conversations with them, and on January 7, 2008, requested additional information based on the October 24, 2007 original submital. The current ATC submittal does not propose concrete construction as initially envisioned, but rather a re -working of the current earthen pond with a new reinforced EPDM liner, and dual pumps (one as a back up) with float controls and telemetry alarms, all under the stamp and signature of their in-house PE. It all looks ok to me. I'm prepared to send them an ATC letter for the proposed system, pending your ok/input. d) Yesterday's submittal shows you on distribution, so l presume you have.a copy of the latest drawings. Let me know if you don't. e) Are you OK with issuing the ATC? Can I proceed? 2 of 3 7/24/2008 2:55 PM State of North Carolina Department of Environment, Health and Natural Resources Division of Environmental Management James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director [ _4i7L .A�� [DEHNR April 7, 1995 Mr. Donald Lineberry Benchmark Carolina Aggregates P. O. Box 13983 Research Triangle Park, NC 27709-3983 Subject: NPDES No. NCG020052 Benchmark Carolina Aggregates formerly: Nello Teer- Crabtree Quarry Wake County Dear Mr. Lineberry: In accordance with your request dated March 17, 1995, we are forwarding herewith the modified Certificate of Coverage page for the subject facility. The only change is in the formal owner's name. This Certificate of Coverage is issued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between North Carolina and the U. S. Environmental Protection Agency dated December 6, 1983. If any parts, measurement frequencies or sampling requirements contained in this permit are unacceptable to you, you have the right to request an individual permit by submitting an individual permit application. Unless such demand is made, this certificate of coverage shall be final and binding. Please take notice that this certificate of coverage is not transferable except after notice to the Division of Environmental Management. The Division of Environmental Management may require modification or revocation and reissuance of the certificate of coverage. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Environmental Management or permits required by the Division of Land Resources, Coastal Area Management Act or any other Federal or Local governmental permit that may be required. If you have any questions concerning this permit, please contact Steve Ulmer at telephone number 919/733-5083, Ext. 545. Sincerely, Preston ward, Jr., P.E. cc: Raleigh Regional Office Compliance -Jeanne Phillips, ISB Central Files P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-5083 FAX 919-733-9919 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT, HEALTH, AND NATURAL RESOURCES DIVISION OF ENVIRONMENTAL MANAGEMENT GENERAL PERMIT NO, NCG02QOOO CERTIFICATE OF COVERAGE_.NO. NCG02QQ52 STORMWATER, MINE DEWATERING, AND/OR OVERFLOW FROM PROCESS WATER RECYCLE SYSTEMS DISCHARGES ' NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Benchmark Carolina Aggregates is hereby authorized to operate or continue operation of a treatment system for mine dewatering and/or recycle systems process wastewater overflow with the discharges of treated wastewater and discharge stormwater from a facility located at Crabtree Quarry NCSR 1664 Wake County to receiving waters designated as the Crabtree Creek in the Neuse River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III and IV of General Permit No. NCGO20000 as attached. This Certificate of Coverage shall become effective April 7, 1995. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day April 7, 1995. K. Preston ard, Jr., P.E., Director Division of nvironmental Management By Authority of the Environmental Management Commission o�oF W A r�RQt✓ r p � CERTIFIED MAIL RETURN RECEIPT REQUESTED 7006 0810 0002 6048 6509 Justin Williams, Vice President Hanson Aggregates Southeast, Inc. 2310 Parklake Drive, Suite 550 Atlanta, Georgia 30345 Michael 1. Easley, Govenwr William G. Ross, Jr., Secretary North Carolina Department of Environment and Natural Resources July 6, 2007 Colleen 11, Sullins, Director Division of Water Quality Subject: Notice of Violation and RECOMMENDATION FOR ENFORCEMENT NOV-2007-PC-0472 Hanson Aggregates Southeast Crabtree Quarry Discharge of untreated Process Wastewater NPDES Permit Certificate of Coverage NCG020052 Wake County Dear Mr. Williams: On July 2, 2007 and July 5, 2007, Judy Garrett of the Raleigh Regional Office conducted a compliance inspection due to a citizen's complaint of a white plume observed in Crabtree Creek below the Quarry on Saturday, June 30, 2007, Ken Pickle of the DWQ Central Office accompanied Judy Garrett during the July 5, 2007 site visit. This letter concerns a discharge of untreated process wastewater from a holding pond breach which reportedly occurred on June 30, 2007. It also transmits the results of the compliance inspection of the facility. Judy Garrett visited the facility with Land Quality Inspectors, on July 2, 2007. It was found that on Friday June 29, 2007, the holding pond -berm at the rock crusher failed and about 50,000 gallons of untreated water and solids was discharged to Crabtree Creek after Hanson staff left the facility. It was reported that the transfer pump in this pond was turned off and it had no float control. As a result, the berm failed during the approximately 1 inch of rain that fell that night. This failure was found by Hanson staff at about 6 am on June 30, 2007. The berm was temporarily repaired, but no report of the discharge overflow was made to DWQ. Additionally, a large deposit of wastewater solids was observed along the bank of Crabtree Creek, During this same site visit on July 2, 2007, evidence of solids discharge was observed from the piles of material that had been removed from the ponds on the south side of Crabtree Creek. This material was piled about 15-20 feet high beside the ponds, on the creek side. A previously constructed sediment basin was full of solids and solids were traced down the creek bank to the creek. During the July 5, 2007 site inspection, DWQ noted many deficiencies in the company's compliance with permit requirements. A Stormwater Best Management Practices Plan is required which outlines the BMPs that are in place to prevent contaminants form entering surface water via stormwater. The plan (T)Must be improved to include all requirements of Part III Section A. of the permit. The plan must also include Preventive Maintenance and Good Housekeeping Practices as required by this section. No Omo�itoring_has been conducted on stormwater discharges, either analytical or qualitative as required by Part III, Section B of the permit. All deficiencies are violations of Part III of the Permit. The DMRs for the wastewater outfall 001 were reviewed and found to be complete. Onc NI O l h}}C aro J�i'r[!1i'a, Nrnth Carolina Division of Water Quality Raleigh Regional Office Surface Water Protection Nhone (919) 7914200 Customer Service Intemet: h2o.enr.state.nc.us 1628 Mail Service Center Raleigh, NC 27699-1628 FAX (919) 571-4718 1-877- 623-6748 An Equal Opportunity/Affirmalive Action Employer — 500% Recycled/10% Post Consumer Paper Mr. Williams Page 2 of 2 A checklist detailing the inspection is attached. As a result of the inspections, the following violations are noted and detailed below: 1) Violation of Part II, Section B 2 of NPDES Permit NCG020000: The above -mentioned discharge to Crabtree Creek is a violation of Part II, Section B 2. of the perm it. 2) Violation of Part IV, Section E 8 of NPDES Permit NCG020000: Failure to report the above -mentioned discharge within 24 hours of the discharge is'a violation of Part IV, Section E 8 of the permit. 3) Violation of Neuse Buffer Rules: The large deposit of wastewater solids observed along the creek bank is a violation of Title 15A NCAC 02B .0233 (4) which states that Zones 1 and 2 of the riparian buffer remain in vegetation that is undisturbed except for those uses provided for in Item (6) of this Rule. 4) Violation of Part IV, Section C 1 - Proper Operation and Maintenance of NPDES Permit NCG020000: The material piled -up about 15-20 feet high beside the ponds and the sediment basin was full of solids and solids were traced down the creek bank to the creek. 5) Violation of Part III Section A of NPDES Permit NCG020000: from the abscense of a Stormwater Best Management Practices Plan. 6) Violation of Part III Section B of NPDES Permit NCG020000: from the absence of analytical or qualitative monitoring as required by the permit. Required Response This Office requires that you respond to this letter in writing within 30 days of receipt of this Notice. Your response should be sent to both this office at the letterhead address and to the attention of Mr. Danny Smith at the Wetlands and Stormwater Branch, NPS Assistance and Compliance Oversight Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. Your response should address the following items: 1. You must submit a plan that addresses all the above mentioned violations and to bring your facility into complete compliance with the NPDES Permit. 2. Your plan should include a permanent plan to provide reliability to the treatment system including pumps with float controls and alarms, including telemetry systems. jj . - s tra r ��-U n � 3. Your staff has indicated that the company intends to build a concrete basin to`replace the current earthen basin at the rock crusher.' All additional wastewater treatment facilities and equipment i must receive an Authorization to Construct prior to installation as outlined in Part II Section A ofi the permit. Please call Ken Pickle at (919) 733-5083 extension 584 concerning questions about obtaining Authorization to Construct 4. ',We request that the detailed map of the facility be revised to include all stormwater and wastewater outfalls, direction of stormwater flow and show all treatment facilities. 5. Please submit a plan to remove the deposited material on the creek bank that resulted from the berm breach. This material must be removed, but no heavy equipment may be used for this purpose. You must use manual labor and such tools as shovels and buckets. Care must be taken to prevent further discharge of this material to Crabtree Creek. You may need to restore Mr. Williams ' Page 2 of 2 the impacted buffer with approved plantings. Questions concerning this removal process and/or restoration should be directed to Lauren Cobb Witherspoon of the Raleigh Regional Office at (919) 791-4200. This removal should be completed prior to July 20. 2007. Any restoration efforts must be approved by this Office. Thank you for your attention to this matter. This Office is considering sending a recommendation for enforcement to the Director of the Division of Water Quality regarding these issues and any future/continued violations that may be encountered. Your above -mentioned response to this correspondence will be considered in this process. This office requires that the violations, as detailed above, be abated immediately. These violations and any future violations are subject to a civil penalty assessment of up to $25,000.00 per day for each violation. Should you have any questions regarding these matters, please contact Judy Garrett at or myself at (919) 791-4200. Sincerely, Shannon Langley Acting Water Quality Regional Supervisor Cc: Lauren Cobb Witherspoon Ken Pickle Danny Smith — NPS ACO Unit Central Files Jim Hilton, Hanson Aggregates Southeast, P.O. Box 52039, Raleigh, NC 27612 Permit: NCG020052 SOC: County: Wake Region: Raleigh Compliance Inspection Report Effective: 01/19/05 Expiration: 12/31/09 Owner: Hanson Aggregates Southeast Inc Effective: Expiration: Facility: Hanson Aggregates - Crabtree Quarry 5001 Duraleigh Rd Contact Person: Robert Snyder Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 07/05/2007 Primary Inspector: Judy E Garrett Secondary Inspector(s): Title: Entry Time: 09:00 AM Raleigh NC 27612 Phone: 919-380-2746 Certification: Exit Time: 12:00 PM Phone: Phone: 919-791-4200 Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Mining Activities Stormwater Discharge COC Facility Status: Q Compliant ■ Not Compliant Question Areas: 0 Storm Water (See attachment summary) Page: 1 Permit: NCG020052 Owner - Facility: Hanson Aggregates Southeast Inc Inspection Date: 07/05/2007 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: Page: 2 Permit: NCG020052 Owner - Facility: Hanson Aggregates Southeast Inc Inspection Date: 07/05/2007 Inspection Type: Compliance Evaluation Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? ■ ❑ ❑ ❑ # Does the Plan include a General Location (USGS) map? ❑ ■ ❑ ❑ # Does the Plan include a "Narrative Description of Practices"? ■ ❑ ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? i ❑ ■ ❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? ❑ ■ ❑ ❑ # Has the facility evaluated feasible alternatives to current practices? ❑ ■ ❑ ❑ # Does the facility provide all necessary secondary containment? ■ ❑ ❑ ❑ # Does the Plan include a BMP summary? ❑ ■ ❑ ❑ # Does the Plan include a Spill Prevention and Response Plan (SPRP)? ■ ❑ ❑ ❑ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? ❑ ■ ❑ ❑ # Does the facility provide and document Employee Training? ■ ❑ ❑ ❑ # Does the Plan include a list of Responsible Party(s)? ■ ❑ ❑ ❑ # Is the Plan reviewed and updated annually? ❑ ■ ❑ ❑ # Does the Plan include a Stormwater Facility Inspection Program? ❑ ■ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? ❑ ■ ❑ ❑ Comment: There was a failure of a settling pond dyke at the rock crusher which resulted in discharge of 50,000 gallons of water and solids to Crabtree Creek. A general location map is needed. The detailed site map must indicate all outfalls, both stormwater and wastewater. It must also indicate the direction of the stormwater flows and all treatment units. All spills of chemicals and wastewater must be included in the plan. The plan must address alternatives to current practices and a summary of MPS. It must also include a preventive maintenance and good housekeeping plan. The plan must be reviewed and updated annually. It must contain an inspection program. The Stormwater PPP must be completed and implemented. Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? ❑ ■ ❑ ❑ Comment: All stormwater only outfalls must be itentified and monitored as required by the permit. Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring?' ❑ ■ ❑ ❑ # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ❑ ■ ❑ ❑ Comment: The analytical monitoring for the wastewater outfall 001 has been completed. The stomwater only outfalls must be monitored as required by the permit. Permit and Outfalls Yes No NA NE Page: 3 Permit: NCG020052 Owner - Facility: Hanson Aggregates Southeast Inc Inspection Date: 07/05/2007 Inspection Type: Compliance Evaluation Reason for Visit: Routine # Is a copy of the Permit and the Certificate of Coverage available at the site? M ❑ ❑ D # Were all outfalls observed during the inspection? Q ■ ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? ❑ ❑ ■ ❑ # Has the facility evaluated all illicit (non stormwater) discharges? ❑ M Q 0 Comment: The plan must indicated the investigation and elimination of any illicit discharges. All stormwater outfalls must be identified and monitored as required. Page: 4 ; RECEIVED ? off blocks, O C T 2 4 2007 v.erhfnc overt tOu]� r�2rc�PnPi1 BY. 2ioi Hanson HEIDELeERGCEMENTGroup /� i a��t -��t bo�✓� cl�, i�S a-F- nP�J G1rc��nr�yG +�� f�. W���" 1�P�J •I�Ac��'G+r`PS P5'Ir�Ii$�,j 4` :�. Flog -I October 19, 2007 on Cale /Ovm�o /ors e lr-v� �Jia� ? (%) A"� �' �iJ %l)J��/l C/ �ir?Fo Mr. Kenneth Pickle, Environmental Engineer II North Carolina Department of Environment and Natural Resources Division of Water Quality 1628 Mail Service Center Raleigh, NC 27699-1628 Hanson Aggregates Mideast Southeast Area North Carolina Territory Office 2300 Gateway Centre Boulevard Morrisville, NC 27560-9626 Tel 919 380 2610 Fax 919 380 2616 www.hanson.com Re: Notice of Violation, NOV-2007-PC-0472, Hanson Crabtree Quarry, Basin Discharge Design Dear Mr. Pickle: n f� SuG 711-0 4) We are submitting for your review the proposed design for the Crabtree Quarry storm water basin. The design includes a clay wall structure lined with EPDM rubber (ethylene, propylene, diene monomer) commonly referred to as rubber roofing, and covered with. washed crushed stone. Site personnel have implemented a number of storm water control and diversion measures that have greatly reduced the drainage area for this basin. Our design engineers have completed a design capable of controlling a 25 year, 24 hour storm event. An integral part of the design is the use of a dry prime, automatic self priming auto start, high head, two float assembly control, approximately 3200 gallon per minute, 8" diesel pump. The float system will allow the pump to operate independently, 24 hours per day, on a precipitation dependent basis. The 3200 gallon per minute pump will be capable of removing water from the basin and discharging to the quarry pit during a 25 year, 24 hour storm event. An identical, in specifications, back up pump will be included pursuant to the Division of Water Quality request. The pumps will incorporate a dial alert system for after hours monitoring and an additional fuel tank. Operationally, the processing plant will continue to function as before with regard to the flow of water during working hours. Subject to your approval of this design we will acquire the pumps. We estimate the basin construction to take approximately 3 to 4 days with work performed as much as possible during a dry weather. Work on the basin construction will begin as soon as weather permits. u —jam c on A/0I/ �or+ca, 7'rx�r ; C� c.��-�u, , &e. 'r�'e%� G1-1 10/ C019/0h,34r- — Please contact me should you require additional information. Sincerely, Robert Snyder Environmental Manager Encl.: Basin Design and Supporting Calculations cc: David Morgan, Hanson Morrisville James Hilton, Hanson Crabtree Mr. John Holly, PE NC Department of Environment and Natural Resources Raleigh Regional Office 3800 Barrett Drive Raleigh, NC 27609 Ms, Judy Garrett North Carolina Department of Environment and Natural Resources Division of Water Quality 1628 Mail Service Center Raleigh, NC 27699-1628 Crabtree Quarry Hanson Aggregates Inc Mideast Region Runoff calculations and design of sediment pond for crushing plant area Design requires 1 - 3200 gpm pump. Storm Runoff Calculations: Rational Method: Q=CiA where: Q = peak rate of runoff (cfs) C = runoff coefficient i = average intensity of rainfall (inlhr), for a storm duration equal to the T, A = drainage area in acres Time of Concentration: Tc _ [(L31H)o.3es)]I128 where: L = hydraulic length of watershed (ft) H = elevation difference along the hydraulic length Flow Path 1 L = 418 H = 14.5 T, = 2.97 Given: Drainage Area Run Off Coefficient Hydraulic Length Elevation Difference Rain Intensity (inlhr) i2 yr = 5.80 i25 yr = 8.50 i50 yr = 9.10 i100 yr = 10.00 Estimated Runoff Calculation 2 3 614 601 32 46 3.42 2.90 Use Tc = 5 minutes 2.2 acres 0.6 ✓ 614 ft 32 ft RECEIVED O C T 2 4 20O7 fly; �Q2 yr = 7.66 cfs % _Q25 yr = 11.22 cfs Q50 yr = 12.01 cfs C' ��a k -r 1 o Q100 yr = 13.20 cfs 2 C S ���con Rce6 noW Inflow Hydrograph Ultimate Soil Capacity = S = 10001CN - 10 where: S = soil capacity (in) CN = SCS curve number Hydrologic Soil Group D = high runoff potential, newly graded area CN = 94 5 _ I0" ti 1 D ► fig- 6�J S = 0.64 in. ✓ 94 � E2!�� 6.5 in. ✓ Estimated Depth of Runoff = D, = (P - 0.2S) 2 I (P + 0.8S) where: Dr= depth of runoff (in) P = 25yr - 24hr storm event (in) S = ultimate soil capacity D� r= 5,79 in. O'e" Estimated Time of Peak = Tp = (43.5*Dr* A)1 Q where: Tp = time of peak (min) Dr = depth of runoff (in) A = drainage area (acres) Q = peak flow 25yr storm event (cfs) To = 49,40 min. ✓ - d 9.30) ,,� Inflow Hydrograph for 25yr storm event: For time between 0 and 125Tp: Q = Qp12*(1-cos(pi(t)/Tp)) For time greater than 1.25Tp: Q = 4.34*Qp*exp((-1.30(t/Tp )) Given: Tp = 49.40 min. " Qp = 11.22 cfs ✓ Time Flow (min) (cfs) 0 0.00 10 1.10 20 3.96 30 7.46 40 10.25 + 40�h (50 11.22 ✓ DPSi�r, �PA� IOu! 60 9.99 70 7.72 80 5.93 90 4.56 100 3.50 110 2.69 120 2.07 130 1.59 140 1.22 150 0.94 160 0.72 170 0.56 180 0.43 190 0.33 200 0.25 210 0.19 220 0.15 230 0.11 240 0.09 250 0.07 260 0.05 270 0.04 280 0.03 290 0.02 300 0.02 310 0.01 320 0.01 330 0.01 340 0.01 350 0.00 360 0.00 370 0.00 380 0.00 390 0.00 400 0.00 Determine Stage -Storage Curve (Single Basin): Accum. Area Avg. Area Depth Volume Volume Elevation (sf) (sf) (ft) (cf) (cf) 239 397 198 1 0 0 240 1474 935 1 935 935 241 2534 2004 1 2004 2939 242 3593 3064 1 3064 6003 243 15520 9557 1 9557 15559 Note: To allow for 2 ft freeboard 244 27447 21483 1 21483 37043 max. water surface = 243.5 r Pump Discharge Capacity: CO) 4, v Pump 1 discharge = 3200 gpm 7.13 cfs Determine Stage -Discharge Curve: Stage Pump 1 Elevation (ft) (cfs) 239.0 0.0 0.00 239.5 0.5 0.00 240.0 1.0 0.00 2 240.5 J'241-0 1.5 2.0� 0.00 7.13 24'1-5 2 5 7.13 242.0 3.0 7.13 242.5 3.5 7.13 243.0 4.0 7.13 243.5 4.5 7.13 244.0 5.0 7.13 Storm Routing - 25yr - 24hr Event: 3200 GPM Pumps Pump 1 Time Inflow Storage Stage Outflow (min) (cfs) (CO (ft) Elevation (cfs) 0 10 20 30 40 rr1 a x 50 0.00 1.10 3.96 7.46 10.25 11.22. 60 9.99 70 7.72 80 5.93 90 4.56 100 3.50 110 2.69 120 2.07 130 1.59 �140 1.22 150 0.94 160 0.72 170 0.56 180 0.43 190 0.33 200 0.25 210 0.19 220 0.15 230 0.11 240 0.09 0.0 0 239 0.0 0.0 0.00 239.00 0.0 657.9 0.70 239.70 0.0 3032.5 �2:03 241.03 0:0� 7511.2 �3.16 242.16 7;1, �vmQ on /�v 244.0 9381.3 3:35J 242.35 7.l 11833.1 3.61 242.61 g 7.1 13551.7 max 3.79 242.79 �" 7.1 13922.7 3.83..E 242.8_3 _rl7.1 MaxWSEL = 242.8 13222.3 Sa 3.76 242.76 7.1 11698.3 3.60 242.60 7.1 9541.3 3.37 242.37 7.1 6897.8 3.10 242.10 7.1 a 3880.2 -2.31 241.31 7.1 575.2 r 0.62 � 239.620 � �J -0 1309.3 rZ 7 1 / U Project y�a. C1'.J —,pr� Page of File By Date 2 b~T mom ®®® ®'®Hanson Hanson Aggregates, Inc. 8505 Freeport Pkwy Irving, TX 75063 www,hanson.biz 11 Hanson Aggregate ATC containment pond Subject: Hanson Aggregate ATC containment pond From: Ken fickle <ken.pickle a ncmail.net> Date: Mon, 07 Jan 2008 11:06.48 -0500 To: robert.snyder@hanson.com CC: Judy Garrett <Judy.Garrett@ncmail.net>, Danny Smith <Danny.Smith cr ncmail.net> on I've looked at the two drawings dated 11-21-07 depicting proposed construction for the detention basin at the Crabtree Quarry. I apologize for my delay reviewing them. I cannot issue an Authorization to Construct without further information or discussion or drawing revisions on the following points. a) The backslope of the proposed basin scales to a slope of approximately 1-1/2 : 1. I obtained this value by comparing the section elevations of the berm (-245 top and 225 toe, or 20' fall) and the plan view of the backslope at approximately 30' wide. Absent any corroborating soils information I'm not confident that such a slope provides long term soil stability of the backslope of the basin. Please address this ✓ in a resubmittal. b) The EPDM liner is identified as "Non -reinforced". Absent any corroborating experience with this material, it seems to me that a reinforced membrane would be preferable. The resistance of the liner to puncture and its dimensional stability could be critical to the long term integrity of the earthen construction detention basin. Please provide a scrim -reinforced liner. Also please provid liner specs that 7� establish the long term UV resistance in the liner material. c) The typical sump detail confuses me with respect to the pump on and pump off elevations. First, it seems they have been mistakenly reversed with the pump off elevation erroneously set above the pump on elevation. Second, even if this reversal is corrected, these are very large pumps, and with only one foot of separation between the pump on and pump off elevation, you may have large motors with very frequent on -off cycles. Perhaps this is standard practice in the industry, but it runs counter to my experience in other applications. Please clarify for me the intended pump operating cycles. ld) I'm confused about the upslope limit of the detention basin. On the emergency spillway section I see a weir elevation of 243.50', but I see no continuation of the berm on the upslope side. Is it your intent that at maximum water elevation the basin will spread upslope, under the operating equipment? e) On Sheet 2, the Site Map, I see a dark feature that runs approximately 300' along the top of bank. But I see no corresponding representation on the part plan of the detention basin area, nor any detail of this feature. What is it? Please make the two drawings consistent with each other. f) I need three copies of the plans. g) All this work must be the work product of a PE, or under his specific direction-. This fact is attested to by the placing of the responsible PE's seal and signature on the drawings. Please provide stamped, signed drawings. I O l 1 /7/2008 1 1:07 AM February 7, 2008 NC DFNR DWQ Storm Water Permitting Unit 1617 Mail Service Center Raleigh, NC 27699-1617 Attn: Mr. Ken Pickle Dear Mr. Pickle: i mom ONE ' O' Hanson HEIDELBERGCEMENTGroup Hanson Aggregates Mideast Southeast Area North Carolina Territory Office 2300 Gateway Centre Boulevard Morrisville, NC 27560-9626 Tel 919 380 2610 Fax 919 380 2616 www.hanson.com In response to your e-mail correspondence dated January 7, 2008,.please find enclosed three copies of the revised plans for the containment pond for the Crabtree Quarry. The following comments and revisions to the plan were prepared by Mr. Alien King, a Lehigh Hanson employee and professional engineer licensed in the State of North Carolina. Comments and revisions to the plans are as follows: A. The slope as shown on the Section A -A on sheet #1 (--245 top and 225 toe) is the existing slope from the plant down to Crabtree Creek. The portion of the slope from elevation 225 to 240 has been in place since the construction of the plant approximately in the late 1950's. This area has been constructed of structural fill, rock and rip -rap. Over ✓ the course of the years this slope has established with volunteer vegetation. To modify this slope would require permitting from the Corp of Engineers and Division of Water Quality. The back slope of the basin is under the plant area and, therefore, not possible to change. The interior slope of the basin was designed utilizing the grade elevations as surveyed. As a rule of thumb, for embankment stability, the sum of the horizontal component of the internal & external slopes should equal 5 or greater (meaning if the interior slope is 2:1 the exterior slope should be 3:1 or greater). Using the existing exterior slope estimated by Mr. Pickle (1.5:1) the interior slope should be constructed at 3.5:1 slope. The details and plans have been modified to reflect the change in the slopes. As shown, this change moves the center line of the basin approximately 4 feet towards the plant. This would make an insignificant change in the volume of the basin. ✓ B. The detail showing the EPDM membrane has been revised to show a reinforced pond liner membrane 45 mil. thick. C. The pump float settings have been revised as follows: Pump On & Pump Off elevation equals 241.0, the emergency Pump Off elevation will be been set at 243.5. The float settings are such that the 'pump off' elevation allows for the basin to be dewatered without the sump being completely drained. The `pump on" elevation has been set for 241.0. �.. ��: �' �, :w `' ,. . ..-� �. �'� { fir' �r� �,l1( �.' -ti' ?; Given the small basin size and the estimated 025 of 11.22 CFS, with these float settings the pump (capacity is 3500 GPM) will cycle as; basin fill time for 35 minutes and pump run time for 80 minutes. The upper "pump off' elevation of 243.5 has been set at the same elevation as the crest of the emergency spillway. This has been set such that in the event that water surface elevation of Crabtree Creek rises to the point such that it begins to back flow into the basin the pumps will be shut off so as to not allow for creek water to be pumped into the pit. As the creek water level drops, power to the pumps can be restored and pumps automatically restarted. D. The upslope limit of the basin terminates at the foundation of the plant structure. Since the installation of the basin, during large storm water events, water does back up and spread under the plant. Although the water does back up under the plant the 3500 GPM capacity pumps keeps this to a minimum. E. Acknowledged and revised. We trust that this information is sufficient for your review and approval. Should you have additional questions feel free to contact me. Sincerely, Robert Snyder Encl.: cc: James Hilton LeHigh Hanson Crabtree Ms Judy Garrett Mr. John Holley, PE NC Department of Environment and Natural Resources Raleigh Regional Office 3800 Barrett Drive Raleigh, NC 27609 Ms. Judy Wehner NC Department of Environment and Natural Resources Division of Land Resources Land Quality Section 1612 Mail Service Center Raleigh, NC 27699-1612 Hanson Aggregate Crabtree Quarry Subject: Hanson Aggregate Crabtree Quarry From: Ken Pickle <ken.pickle@ncmai1.net> Date: Tue, 12 Feb 2008 08:24:22 -0500 To: Judy Garrett <Judy. Garrett@ncmai 1. net> CC: Danny Smith <Danny. Smith@ncmail. net>, Bradley Bennett <Brad1ey.Bennett@ncmai1.net> Hi Judy, Re: NOV for Hanson Crabtree Quarry, NCG020052 a) I received the revised drawings for the Hanson holding pond yesterday. They have addressed all my concerns from an additional information request, and I'm ok with issuing an ATC based on the calcs I received October 24, 2007, and on the revised drawings I received yesterday. b) RRO's July 6, 2007, NOV letter Lists the required response from Hanson as, 113. Your staff has indicated that the company intends to build a concrete basin to replace the current earthen basin at the rock crusher. All additional wastewater treatement facilities and equipment must receive an Authorization to Construct prior to installation as outlined in Part II Secretion A of the permit. Please call Ken Pickle at (919) 733-5063 extension 584 concerning questions about obtaining Authorization to Construct." Also, item 2 of the required responses in the NOV letter requires float controls and telemetry alarms. c) I have met with those folks, had a couple of phone conversations with them, and on January 7, 2008, requested additional information based on the October 24, 2007 original submital. The current ATC submittal does not propose concrete construction as initially envisioned, but rather a re -working of the current earthen pond with a new reinforced EPDM liner, and dual pumps (one as a back up) with float controls and telemetry alarms, all under the stamp and signature of their in-house PE. It all looks ok to me. I'm prepared to send them an ATC letter for the proposed system, pending your ok/input. d) Yesterday's submittal shows you on distribution, so I presume you have a copy of the latest drawings. Let me know if you don't. e) Are you OK with issuing the ATC? Can I proceed? Ken 1 of 1 2/12/2008 8:25 AM Hermit Coverage AT,©► � Renewal Application Form NCDENR National Pollutant Discharge Elimination System NPDES Permit Number Stormwater Individual Permit NCG020052 Please provide your permit number in box in the upper right hand corner, complete the information in the space provided below and return the completed renewal form along with the required supplemental information to the address indicated. Owner Information - Address to which permit correspondence will be mailed Owner / Organization Name: Hanson Aggregates Southeast, _ Owner Contract: Scott Dickson _ Mailing Address: 2310 Parklake Drive Atlanta GA 30345 Phone Number: _(70) 491-2757__ Fax Number: (770) 491-2788 E-mail address: 5=.Dickson pnson.com Facility Information Facility Name: _Hanson Aggregates — Crabtree Quarry Facility Physical Address: 5001 Duraleigh Road Raleigh, NC 27612-7627 _ Facility Contact: Jim Hilton Mailing Address: 5001 Duraleigh Road _ T Raleigh, NC 27612-7627 Phone Number: 919 787-0613 Fax Number: 914 781-2412 E-mail address: ;ALogs.Hilton@bpft%M.com on.com Permit Information Permit Contact: Jack Garvey Mailing Address: 2101 Gateway Centre Blvd, Suite 1.00 _ Morrisville, NC 27560 Phone Number: (919) 380-2746 Fax Number: - (919) 360-2756 - 1/ E-mail address: 4ck.GarvgXj2hanson.com Dischar Receiving Stream: Crabtree Creek Stream Class: C Basin: Neuse River Sub -Basin: Number of Outfalls: 4 Facility /Activitrr Chances Please describe below any changes to your facility or activities since issuance of your permit. Attached a separate sheet if necessary. SDO-3 was eliminated in 2010 by re-routing the stormwater to the pit. Our pending mine permit modification shows another proposed location for SDO-3. CERTIFICATION I certify that I am familiar with the information contained in the application and that to the best of my knowledge and belief such information is true, complete and accurate. LL,� SignatureI Date Print or type name of person signing above Title SW Individual Permit Coverage Renewal Please return this completed application form Stormwater Permitting Program and requested supplemental information to: 1612 Mail Service Center Raleigh, North Carolina 27699-1612 - _L A NCDENR North Carolina Department of Environment and Natural Resources Beverly Eaves Perdue Governor Mr. Justin E. Williams Hanson Aggregates Southeast, LLC 2310 Parklake Drive, Suite 550 Atlanta, GA 30345 Dcar Mr. Williams: Division of Water Quality Coleen H. Sullins Director March 19, 2009 Dee Freeman Secretary Subject: NPDES General Permit NCG020000 Certificate of Coverage NCG020052 Hanson Aggregates Southeast, LLC Formerly Hanson Aggregates Southeast, Inc. Wake County On March 1, 2009, Division personnel received your request to revise your stormwater permit Certificate of Coverage to accurately include you new company name. Please find enclosed the revised Certificate of Coverage. The terms and conditions contained in the General Permit remain unchanged and in full effect. This revised Certificate of Coverage is issued under the requirenncnts of North Carolina General Statutes 143-215.1 and the Memorandum of Agreement between North Carolina and the U.S. Environmental Protection Agency.. If you have any questions, please contact the Stormwater Permitting Unit at (919) 807-6303. Sincerely, Coleen H. Sullins cc: DWQ Central Files Raleigh Regional Office Stormwater Permitting Unit Wake County Wetlands and Slormwater Branch 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Location: 512 N. Salisbury St. Raleigh, North Carolina 27604 Phone: 919-807-6300 Y FAX: 919-807-64941 Customer Service: 1-877-623-6748 IntemeL wvnv.ncwaterqua14y.org An Equal Opportunity 1Affiirmative Action Employer One NorthCarolilia Naturall# STATE OF NORTH CAROLINA DEPARTMENTOF ENVIRONMENTAND NATURAL RLSOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCG020000 CERTIFICATE OF COVERAGE No. NCG020052 STORMWATER AND PROCESS WASTEWATI?R DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, HANSON AGGREGATES SOUTHEAST, LLC is hereby authorized to discharge stormwatcr and to operate treatment systems and discharges associated with mine dewatering wastewater and process wastewater from a facility located at HANSON AGGREGATES SOUTHEAST, LLC 5001 DURALEIGH ROAD RALEIGE-1 WAKE COUNTY to receiving waters designated as Crabtree Creek, a class C NSW stream, in the Neuse River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts 1, 11, 111, 1V, V, and VI of General Permit No. NCG020000. This certificate of coverage shall become effective March 19, 2009 This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day March 19, 2009 for Coleen I -I. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Don Bright Engineerinc, PLLC PO Boy: 2291 ® Garner, NC 27529 (919) 961-2490 November 3. 2009 5tormwater Permitting Unit NC Division of Water Quality 16i 7 Mail Ser;,ice Center R.alciuh.. NC- 27699-1617 subliect: 13n,iineer's Certificstim :'%:Oi ` NCG020,052; Crabtree Quarrr i;ontainment Pond NOV-2007_PC-0472 NPDES General Permit CO wake C,-,unty TO W lolll 1t May Concern: Enclosed Please find the conivIetel l nginecr's Cet, iAl.!6on !or the above referen-A faciliw,,-I.l' you have any question, please conttr l tnc at P 19-961-249 , t, Don Bright. Civil !-'llgineer di . � '. - �' 11 ..` it .. 't,' f � I ',r �•,� � ' j� -- •, Mr. Robert Snyder Page 3 of 3 July 24, 2008 Engineer's Certification (COC NCG020052) I, r kram, as a duly registered Professional Engineer in the State of North Carolina, having biben authorized to observe ( eriodica , weekly, full time) the construction of the project, �rah-fi-ec- Quarrw Cc�N ��m�.v�- tong Project Name Location for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of: The construction and installation of a wastewater containment system at the Crabtree Quarry. I certify that the construction of the above referenced project was observed to be built within substantial compliance and intent of the approved plans and the %69F)7ation to Construct. Signature Registration No. OR9g02 Date 101108 -22 Mail this Certification to: Stormwater Permitting Unit NC Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 CAR '�• ��E,S* 0 SEAL �f 029421 IME;�G`' \ � S. F WATF� i �Q 9p Michael F. Easley, Governor 0 y William G. Ross Jr., Secretary r North Carolina Department of Environment and Natural Resources Coleen H. Sullins, Director Division of Water Quality July 24, 2008 Mr. Robert Snyder Hanson Aggregates Mideast 2300 Gateway Centre Boulevard Morrisville, North Carolina 27560-1617 Subject: Authorization to Construct Crabtree Quarry Containment Pond NOV-2007-PC-0472 NPDES General Permit COC NCG020052 Wake County Dear Mr, Snyder: The Division of Water Quality (DWQ) received your request to construct a wastewater containment pond at your Crabtree Quarry on October 24, 2007, and again with revisions on February 11, 2008. You proposed the approved construction in response to the subject NOV. In accordance with your request, you are authorized to construct the approved containment facilities,_ effective today. ..-- —. __..— ---------- _ -- - - -- --- ---_ Authorization is hereby granted for the construction and installation of a wastewater containment system consisting of: a containment pond with compacted earthen berms, EPDM reinforced liners of 45 mil and 60 mil thickness, a minimum 6" thick stone liner, and an 18" thick riprap liner for the emergency spillway; 2 diesel driven pumps of approximately _350.0-gpm-.capacity_each_and- with . automatic on -off float switches; pump discharge piping; an automatic after hours dial alert alarm/notification system; and two upslope diversion berms, all in the configuration and location shown in the approved plans submitted to DWQ. In addition, the EPDM liner must be anchored at the top of the berm, as well as anchored at the bottom. DWQ staff from the Raleigh Regional Office will re -inspect the riparian buffer near the creek and containment structure to determine if additional plantings are necessary to restore affected vegetation. Construction must be completed no later than November 1, 2008. You must you notify DWQ's Raleigh Regional Office supervisor, telephone number (919) 791- 4200, at least 48 hours in advance of operation of the finished facilities so that regional office staff can conduct an in -place inspection prior to operation of the containment pond. Such notification to the regional supervisor may be made during the normal office hours from 8:00 a.m. until 5:00 p.m, on Monday through Friday, excluding state holidays. Upon completion of construction, you must submit a certification from the designing professional engineer certifying that the facilities have been constructed and installed in accordance with this Authorization to Construct, the approved site plan and details, the submitted narrative description, and the design calculations. Please mail the engineer's certification to DWQ Stormwater Permitting Unit, 1617 Mail Service Center, Raleigh, North Carolina 27699-1617. Our Authorization to Construct is subject to revocation unless the facilities are constructed in accordance with the approved plans, details, narrative description, and design calculations. No`r hCarolina Alditurally North Carolina Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 Phone (919) 807-6300 Customer Service Internet: wwwTncwaterauHliiN,.org Location: S 12 N. Salisbury St. Raleigh, NC 27604 Fax (919) 807-6494 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer— 50% Recycled/10% Post Consumer Paper Mr. Robert Snyder Page 2 of 3 July 24, 2008 You must maintain on file a copy of the approved plans, details, narrative description, and design calculations for the life of the facility. In the event that the system fails to perform satisfactorily, including the creation of nuisance conditions, you must take corrective action, including those actions as may be required by this Division, such as the construction of additional or replacement controls. Any additional construction, installation, or modifications to the wastewater containment system must receive an additional Authorization to Construct from DWQ, prior to construction. Failure to abide by the requirements contained in this Authorization to Construct may subject the Permittee to an enforcement action by DWQ, in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. This Authorization to Construct does not affect the legal requirements to obtain other permits authorizations that may be required by DWQ, or other federal, state, or local government agencies. Please contact Ken Pickle at (919) 807-6376, with any comments or questions. Sincere] ��CnlcoR W Ciillinc ______Attach ment:_Engineer s Certi Enclosure: Approved plans al cc: DWQ Raleigh Regional ( DWQ Central Files, IettE DWQ NPSA&CO3 Sheitoi SPU file NCG020052 or Mr. Robert Snyder Page 3 of 3 3uly 24, 2008 Engineer's Certification (COC NCG020052) I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically, weekly, full time) the construction of the project, , Project Name Location for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of: The construction and installation of a wastewater containment system at the Crabtree Quarry. I certify that the construction of the above referenced project was observed to be built within substantial compliance and intent of the approved plans and the Authorization to Construct. Signature Registration No. Date Mail this Certification to: Stormwater Permitting Unit NC Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 60 mil 6" THICK STONE LINER d 50 = 2" ERM: 245.0 1'FREEBOARD 03' FLOW DEPTH CREST OF WEIR: 243.50 TOE OF BERM: 240.0 SECTION THROUGH WEIR TOE A" §1flfiNWW i Fi Cons IQf? in aWO th@§o 09l required by thsl litBFF«AMlit@F p@rMit: NoFth rules equlln thgl II1L 6t@rftiW§t@i 31 qt@FH € inspect during 00A600110fl; @gfilty fa11199 plans and spimmo. 410� w AWFIF "WQlerrr EMERGENCY SPILLWAY DETAIIPermit # n! 41 n 2 6PS2- _ Data_ NOT TO SCALE �/�� NC Division of Sheet # / e,f Y Revislon Dal z O U) z a z N a m z O P z W H W G DESIGNED: ARK DRAWN: DJ CHECKED: ARK DATE: N6V-07 REGION: MIDEAST LOCATION: - CRAB_EARTH_BERM.DWG DWG FILE: SCALE: HORIZONTAL: 1 L20' VERTICAL: 1'=20' SHEET NO.: OF: CHECKED: NOTE: ARK ADDRESSED COMMENTS FROM THE STATE 2 MAX. W.S. EL. = 242. (25 YRS STORM EVENT) BOTTOM WIDTH — PROPOSED GRADE A -A LEGEND EXISTING CONTOUR UPDATED EXISTING CONTOUR PROPOSED CONTOUR + tee, SPOT ELEVATION EXISTING STRUCTURE 245 240 235 230 225 v C �a m dan�o a.0 CWHmv c 'too a 0 0 kD H Z c uumu ,. m J W W MEN ■■■ ■■■ Q 22064 _ N R. DATE: 11-21-07 v Z LLF eg z a d o W � Z =w Lu 99. W . LV s NEW PUMP LOCATION (AND BACK UP PUMP) 3500 GPM CAPACITY EXISTING BASIN SUMP LOCATION _ EXISTING DISCHARGE - PIPE (TO PIT) :. 5 8 rrOM AERIE, — 4QROp SPOT S1=fc`i'+ CONDITI0,0' SURVEY; DAR E ENCY SPILL Wi�Y °�::-:-:::-:-:::: k• — EOM SECTION w +�::::..-':....•. �WI�H� +05 :.:...�........................ 0. SEE DETAIL w w ::::: ::.......... :':'::....... �. $� ......... 'gypl .� ... :: y.. W w w w .'.'; ......... . n ... ...' ... :...........:.......r............... EPDM MEMBRANE j w w w w a '': ..:':':•.....'.:.:.. Q� LINER : SEE DETAIL :: 4-:::::.......:.....biLO .. w ��O w .� . min FLOAT CONTROL SWITCH 243.5' EMERGENCY OFF 241.0'PUMP ONIOFF 1' - - 236.0' SUMP BOTTOM ' TYPICAL SUMP DETAIL NOT TO SCALE SUCTION LINE FROM PUMP FLOW CHAIN 1 ROPE M 1 l I_ BASKET STRAINER CLASS "B" RIP RA 18" BEDDIN, THICKNES i ILBSIACRE LBSIACRE LBSIACRE LBSIACRE LBSIACRE LBSIACRE LBSIACRE LBSIACRE p LBSIACRE J LBSIACRE PLA 1EW.. GRAPHIC SC 40 20, 10 0 10 20 0 REINFORCED •. WIDTH EPDM•O• LINER '•�•`••`�i��'i•i •STONE LINER - ��f` 1 COMPACTED FILL TOE ANCHOR hTION. 6E EPDM LINER INSTALLATION DETAIL NOT TO SCALE IN 100 50 O No 07 0 340 seo� rtqm(",- z o y z � v � a DESIGNED: ARK DRAWN: DJ CHECKED: ARK DATE: NOV-07 REGION: MIDEAST LOCATION: RAE PLANT DRAINAGE.DWG DW'G FILE: 1 � SCALE. HORIZONTAL: bbebfflm� Corl trtic in in ati�F fs@ W is p'�}t! E�9wil 1"=104' rulesruqufre no Ihe1 the 5t� mWalur syltorm 10 MY Witr Inspect durinp oonstruetlun', oertlN oni�rr++ny with the ItbIba SHEET NO.: plans and $R00% } Permit# eVf/�/l�1GYlSZ —Date by NC Dfvisfon of ter uallly 2 Sheet # Revision Date 4F: EGATE, INC QUARRY N.C. EGION � � rlfrrr�f !i n m � 0 m v z n o m vo m Cn W m v O z O m D 1111113 Hanson Aggregates, Inc ■ A ® 6 6® Hanson 8505 FREEPORT PARKWAY , T1 083 TEL. 47 1 1 TEL. 68 41410 HEIDELBERGUMENTGroup FAX aea 417 1400 Pr OVIII W.E. 257.3 20 -� O UJIMMM STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCG020000 CERTIFICATE OF COVERAGE No. NCG020052 STORMWATER AND PROCESS WASTEWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Hanson Aggregates Southeast Inc is hereby authorized to discharge stormwater and to operate treatment systems and discharges associated with mine dewatering wastewater and process wastewater from a facility located at Hanson Aggregates - Crabtree Quarry 5001 Duraleigh Rd Raleigh Wake County to receiving waters designated as Crabtree Creek, a class C;NSW stream in the Neuse River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, Il, III, IV, V, and VI of General Permit No. NCG020000 as attached. This certificate of coverage shall become effective February 7, 2005, This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day February 7, 2005 for Alan W. Klimek, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission �OF W A r�RQ Michael F. L'asley, Governor �� >✓ William G. Ross Jr., Secretary North Carolina Department of Favironnient and Natural Resources Alan W. Klimek, P.R. Director Division of Water Quality February 7, 2005 Justin Williams Hanson Aggregates Southeast Inc 100 Crescent Centre Pkwy Ste 1240 Tucker, GA 30084 Subject: NPDES Stormwater Permit Coverage Renewal Hanson Aggregates - Crabtree Quarry COC Number NCG020052 Wake County Dear Permittee: In response to your renewal application for continued coverage under general permit NCG020000 the Division of Water Quality (DWQ) is forwarding herewith the reissued stormwater general permit. Please review the new permit to familiarize yourself with the changes in the reissued permit. The general permit authorizes discharges of stormwater and some types of wastewater. You must meet the provisions of the permit for the types of discharges present at your facility. This permit is reissued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between the state of North Carolina and the U.S. Environmental Protection Agency, dated December 6, 1983. The following information is included with your permit package: A new Certificate of Coverage • A copy of General Stormwater Permit NCG020000 A copy of a Technical Bulletin for the general permit Five copies of Discharge Monitoring Report (OMR) Forms - wastewater and Stormwater Five copies of Qualitative Monitoring Report Form Your coverage under this general permit is not transferable except after notice to DWQ. The Division may require modification or revocation and reissuance of the Certificate of Coverage. This permit does not affect the legal requirements to obtain other permits which may be required by DENR or relieve the permittee from responsibility for compliance with any other applicable federal, state, or local law, rule, standard, ordinance, order, judgment, or decree. if you have any questions regarding this permit package please contact Aisha Lau of the Central Office Stormwater Permitting Unit at (919) 733-5083, ext.578. Siinncerelv,/ /J� CL,l J rJ P4- Ul for Alan W, Klimek, P.E. cc: Central Files Stormwater & General Permits Unit Files Raleigh Regional Office No hCarolina ��rtura!!� North Carolina Division or Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 Phone (919) 733-7015 Customer Service Internet h2o.enr.state.nc.ustsulstormwater.html 512 N. Salisbury St. Raleigh, NC 27604 FAX (919) 733-9612 1-877-623-6748 An Equal OpportunAylAffirmative Action Employer— 50% Recycled110% Post Consumer Paper State of North Carolina Department of Environment and Natural Resources Division of Water Quality Michael F. Easley, Governor William G. Ross Jr., Secretary Alan W. Klimek, P.E., Director November 4, 2002 Mr. Steve Howlier Hanson Aggregates Southeast Inc. PO Box 848 Cheraw, South Carolina 29520 1 Z • NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES Subject: NPDES Permit Modification — Name/Ownership Change Permit NCG020052 Crabtree Quarry (Formerly Hanson Aggregates Carolina Inc) Wake County Dear Mr. Howlier: In accordance with your request received February 13, 2002, the Division is forwarding the subject permit modification. This modification documents the change in name at the subject facility. All other terms and conditions in the original permit remain unchanged and in full effect. This permit modification is issued under the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between North Carolina and the U. S. Environmental Protection Agency dated December 6, 1983. If any parts, measurement frequencies or sampling requirements contained in this permit modification are unacceptable to you, you have the right to an adjudicatory hearing upon written request within thirty (30) days following receipt of this letter. This request must be a written petition conforming to Chapter 150E of the North Carolina General Statutes, filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, North Carolina 27699-6714. Unless such demand is made, this decision shall be final and binding. This permit does not affect the legal requirement to obtain other permits which may be required by the Division of Water Quality, the Division of Land Resources, Coastal Area Management Act, or any other Federal or Local government permit that may be required. If you have any questions concerning this permit, please contact Valery Stephens at the telephone number or address listed below. cc: Central Files Raleigh Regional Office, Water Quality Section NPDES Unit 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 VISIT U5 ON THE INTERNET 0 httpWh2o.enr.state.nc.us/ Sincerely, Alan W. Klimek, P.E. 919 733-5083, extension 520 (fax) 919 733-0719 Valery.Stephens @ ncmail, net STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCG020000 CERTIFICATE OF COVERAGE No. NCG020052 STORMWATER, MINE DEWATERING, AND/OR OVERFLOW FROM PROCESS WATER RECYCLE SYSTEMS DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Hanson Aggregates Southeast, Inc. is hereby authorized to discharge stormwater and to operate or continue operation of treatment systems and discharges associated with mine dewatering and process wastewater recycling overflow from a facility located at Crabtree Quarry 5001 Duraleigh Road Raleigh Wake County to receiving waters designated as Crabtree Creek, in the Neuse River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III, IV, V, VI and VII of General Permit No. NCG020000 as attached. This certificate of coverage shall become effective November 4, 2002. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day November 4, 2002. Alan W. Klimek, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission State of North Carolina Department of Environment and Natural Resources Division of Water Quality .tames B. Hunt, Jr., Governor Bill Holman, Secretary Kerr T. Stevens, Director December 17, 1999 DONALD A LINEBERRY BENC14MARK CAROLINA AGGREGATES - CRABTREE QUARRY PO BOX 13983 RTP, NC 27709 Dear Permittee: 4 40 7XA oww%i NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES Subject: Reissue - NPDES Stormwater Permit Benchmark Carolina Aggregates - Crabtree Quarry COC Number NCG020052 Wake County In response to your renewal application for continued coverage under general permit NCG020000, the Division of Water Quality (DWQ) is forwarding herewith the reissued stormwater general permit. This permit is reissued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between the state of North Carolina and the U.S. Environmental Protection Agency, dated December 6, 1983, The following information is included with your permit package: * A copy of general stormwater permit NCG020000 * Five copies of the Analytical Monitoring form and five copies of the Qualitative Monitoring form * A copy of a Technical Bulletin on this permit which outlines permit components and addresses frequently asked questions * A Certificate of Coverage for your facility * DWQ fee schedule Your coverage under this general permit is not transferable except after notice to DWQ. The Division may require modification or revocation and reissuance of the Certificate of Coverage. This permit does not affect the legal requirements to obtain other permits which may be required by DENR or relieve the permittee from responsibility for compliance with any other applicable federal, state, or local law rule, standard, ordinance, order, judgment, or decree. Please note that in 1998 Senate Bill 1366 established changes to the permit fee structure for DWQ permits effective January 1, 1999. This change requires that you pay an annual fee to assure continued coverage under this permit. You will be invoiced for this fee beginning next year. A copy of the current fee schedule is included with this letter. If you have any questions regarding this permit package please contact Tony Evans of the Central Office Stormwater and General Permits Unit at (919) 733-5083, ext. 584 Sincerely, for Kerr T. Stevens Director, Division of Water Quality cc: Central Files Raleigh Regional Office 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Telephone 919-733-5083 FAX 919-733-9919 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCG020000 CERTIFICATE OF COVERAGE No. NCG020052 STORMWATER AND PROCESS WASTEWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215,1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, BENCHMARK CAROLINA AGGREGATES is hereby authorized to discharge stormwater and to operate or continue operation of treatment systems and discharges associated with mine dewatering and process wastewater from a facility located at BENCHMARK CAROLINA AGGREGATES - CRABTREE QUARRY 5001 DURALEIGH ROAD RALEIGH WAKE COUNTY to receiving waters designated as Crabtree Creek in the Neuse River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, 11, 11I, IV, V, and VI of General Permit No. NCG020000 as attached. This certificate of coverage shall become effective December 17, 1999. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day December 17, 1999. for Kerr T. Stevens, Director Division of Water Quality By Authority of the Environmental Management Commission State of North Carolina Department of Environment, Health and Natural Resources Division of Environmental Management James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director June 7, 1993 Donald A. Lineberry P O Box 131 Durham, NC 27702 & LT.WMA IDEHNR Subject: General Permit No. NCG020000 Nello Teer Company - Crabtree Quarry COC NCG020052 Wake County Dear Mr. Lineberry: In accordance with your application for discharge permit received on September 28, 1992, we are forwarding herewith the subject certificate of coverage to discharge under the subject state - NPDES general permit. Issuance of this certificate of coverage supercedes the individual NPDES permit No. NC0003590. This permit is issued pursuant to the requirements of North Carolina General Statute 143-215 .1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection agency dated December 6, 1983. If any parts, measurement frequencies or sampling requirements contained in this permit are unacceptable to you, you have the right to request an individual permit by submitting an individual permit application. Unless such demand is made, this certificate of coverage shall be final and binding. Please take notice that this certificate of coverage is not transferable except after notice to the Division of Environmental Management. The Division of Environmental Management may require modification or revocation and reissuance of the certificate of coverage. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Environmental Management or permits required by the Division of Land Resources, Coastal Area Management Act or any other Federal or Local governmental permit that may be required. If you have any questions concerning this permit, please contact Ms. Susan Robson at telephone number 919/733-5083. Sincerely, Original Signed By Coleen H. Subs A. Preston oward, Jr. Director cc: Raleigh Regional Office P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015 FAX 919-733-2496 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper I� s GENERAL PERMITS COPIES OF PERMITS ARE TO BE SENT I TO THE FOLLOWING: SIGNED ORGINAL TO APPLICANT ** SIGNED COPY TO CENTRAL FILES 7COPY TO REGIONAL OFFICE COPY TO P&E FILE COPY TO COMPLIANCE COPY TO WAKE COUN COPY TO MECKLENBURG COUNTY COPY TO TRAINING & CERT.** **A ACH COPY OF GENERAL PERMIT STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT, HEALTH, AND NATURAL RESOURCES DIVISION OF ENVIRONMENTAL MANAGEMENT GENERAL PERMIT NO. NCG020000 CERTIFICATE OF COVERAGE No. NCGO20052 STORMWATER, MINE DEWATERING, AND/OR OVERFLOW FROM PROCESS WATER RECYCLE SYSTEMS DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Nello Teer Company is hereby authorized to construct and operate a settling basin for mine dewatering and discharge treated wastewater from a facility located at Crabtree Quarry NCSR 1664 Wake County to receiving waters designated as Crabtree Creek in the Neuse River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts 1, II, III and IV of General Permit No. NCG020000 as attached. This certificate of coverage shall become effective June 7, 1993 This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day June 7, 1993 Original Signed By Coleen H. Sullins A. Preston Howard, Jr., P.E., Director Division of Environmental Management By Authority of the Environmental Management Commission NG�Lo Tctr Ca. ^��"' � I�; Yt, � ` \\ 1 / �� 1 tlll`'r �•t � OZ ` ..•;1� •/• ;``�- ;` -�`\\�- _ J�.. �\`�lll �� r�'l� /�� r, )�4 t �j1 S t �� •'ir' 1l�Jq'ny, �. i r%! � S •� I I _ ./ ; ` `-'�' - 'v�� /Ir l : �: (166e .e ,:ff�/ I jl•',1 ..�1 fore ,�t;;�.; I �'�,' ��( i j r � '�% 600 rn • �, ie�aatiL C ;. � �_ %, JJl//ILA �•�.N \ �r��, � ,I f ��r�l �' ` ` I• .'�(T. �/i� � � � �3 Jl �j ���l�,l �,••,, 1} I �� �. _ LEI'=_��` "" ���-• �� `�, li1it.\`'� � ::�-• `� � ��.�':-+,'�P `� .� ••�• �`-• �, vh'oil �\= � � J� ` � 4 l` �� � tom,• � � J � -�` I : . ..l 1�� �irJ .} `} (! _ �( l�r_ "r i 1\ I \ :,`I I [ I , �;,5 Oo �•.� ! � t �T / + ii ��' !r'�1�+ � Ii r. {r ` � \ �I .`,,' t1 —i / iI IU i11. J 1jf ��� 1•. Ij I 1 _.f �i�, I .' rr,,�. it �J' f�� �• I J4 �70 'i em r \ �� y25 III S`� PuvIF �I N + `�� - `^ ,� , / � i,� - � Cn "� I by I • Hanson Quarry revisions Subject: Hanson Quarry revisions From: Ken Pickle <ken.pick le a ncmaihet> Date: Wed, 15 Oct 2008 1 1:28:40 -0400 To: don@ donbright-eng.com CC: Judy Garrett <Judy.Garrett cr ncmail.net> Don, a) As per our meeting today, I am approving minor revisions to the prior approved drawings detailing the re -construction of the pond at Hanson Quarry. b) Those revisions are to be as we discussed in our meeting this morning, as per my mark-up of your drawing, and as per the faxed revised portions of the drawing you faxed me today. c) Due to the time constraints of completing the construction by November 1, and due to my departure today on vacation, I have agreed to expedite my approval this morning, and to provide this written approval in advance of stamped Approved drawings. You have agreed to deliver to me 3 sets of drawings showing the revisions NLT my return from vacation on Tuesday, October 21, so that I can stamp them 'Approved'. d) In part, the basis for my approval is that I understand that you will be on -site during the construction and will implement the minor drawing revisions that we discussed. Ken Pickle DWQ Stormwater Permitting Unit 1 of 1 12/16/2008 10:53 AM 10/151220e 10:21 919-38C-2756 HAHSDN TECH SVC PAGE 01/07 sun ■a■ 0 `" Manson HEIDELBE PoGCEMENTCroup Hanson Aggregates, Inc. 2300 Gateway Centre Blvd. Fax Morrisville, NC 27560 To: Ken Pickle From: Leigh Blackwell Company: NC DENR DWQ Fax: 919-380-2756 Fax. 919-807.6494 Phone: 919-380-2673 Pages: 7 E-Mail (including cover page) Date: 10-15-08 This facsimiie transmission may Contain confidential andlor privileged information, if you are not the intended recipiant (or have received this tax in error) please notify the sender immediately and destroy this facsimile. Any unautharizad copying, disclosuro, distribution or usa of the contents of this informaiYon is strictly prohibited Please )mmediatefy notify us if you have.rac®lvad this message in error. Crabtree Waste Water Containment Pond Update Ken, Attached are the updates previously discussed. • Plan view of the Crabtree Containment Pond • Earthen Berm detail • PE Signature Block • Mark-ups previously discussed We will also be sending 3 original full size stamped prints dated to arrive in your office no later than 10-21-08. Thank you for working with us. We appreciate it. Please, add information about your company it needed ($eatr Raglstar, mernhers of managing board eta,) c EXISTING BASIN SUMP LOCATION GEtiCY SPILLWAY, SECTION SEE DETAIL EPDM MEMBRANE \ LINER N r„ n� Ln cri 0 w r C 1 C) REINFORCED EPDM POND LINER TOP WIDTH 45 mil A 5' VARIABLE VARIABLE (SEE NOTE) (SEE NOTE) �� CLASS B" 1� 1 —1 I I -III —III ---I s., THICK sroHE RIP RAP EARTHEN BERM: LINER 18" BEDDING �I I =i i t - -i i i—i i i---I � I —I I — d50 = 2" THICKNESS I —I I I-- (CLAYEY MATERlAI~) _III —III —I I I� 11 E�EI I IEEli I= I 1 1E III I-1 I I =1 I I-1 I ICI I I=III- 1' FILTER FABRIC COMPACTED FILL UNDER LINER TOE ANCHOR NOTE: PRIOR TO THE INSTALLATION OF THE EPDM LINER, AN EARTHEN BERM CONSISTING OF CLAYEY MATERIAL SHALL BE CONSTRUCTED. THE SIDE SLOPES OF THIS EARTHEN BERM SHALL VARY. THE FINISHED SLOPE OF THE BERM SHALL BE INSTALLED SUCH THAT THE SUM (EXTERIOR AND INTERIOR SLOPE FACES) OF THE HORIZONTAL COMPONENT OF THE SLOPE (H.V) SHALL BE EQUAL TO OR GREATER THAN 5. IN NO CASE SHALL THE INTERIOR OR EXTERIOR SLOPES BE INSTALLED STEEPER THAN 1.5:1 (H:V) FOR EROSION CONTROL PURPOSES THE EXTERIOR SLOPE SHALL BE ARMORIZED WITH A LAYER OF CLASS B RIP -RAP. EPDM LINER INSTALLATION DETAIL NOT TO SCALE m IJ RBMMON VATE [RAY&# GFffCri:7A iiDTE' p � 00 m N �4{Ifyl 0.! ARK ADt]iyF,-2,EO C:LAGFPo0911lff SIAlk iNi S14S AM AAi imvzro mmm Oou mwrooe4mw L2& Rr"m-ADM V f1A= 6 mp- wP UN SL6PE - - ,_{$5YR53'I'OH�IE. 245 246 SEL 240 R35 235 23q M 225 225 SECnOW A.A d� 78 SCAL — 'sOPOF.6ETi3i=2245- 24JD LEGEND E1U571TN3 OOhlTIXlR UPQATEDEKI5TING CONTOUR PROPOSED GOl,ITOUR jvj SPOT ELEYAiION FXISTING STRUCTURE 10/15/2008 10:21 919-380-2756 HANSON TECH SVC PAGE 05/Q7 SUMP LOCATION so SEE DETAIL EPDM ?AEMBRM,`-,,r*,; LINER SEEDING MIX 35 10/15/2008- 10:21 919-380-2756 HANSON TECH SVC i PAGE 06/07 .RE :RE :RE 4RE ME :RE ME 'RE � ,RE ME 44 REINFORCED EPDM POND LINER TOP WIDTH AS mll VARIABLE VARIABLE: / (SEE NOTE) (SEE NOTE) / C ! 6' THICK S7ONE RIPEARTHEN BELINER 14" B G d9Q a 2' THIC E S (CLAYEY MAl>;tBAL COMPACTED FILL TOE ANCHOR NOTE: PRIOR TO THE INSTALLATEON OF THE EPPM l KER, AN EARii EN BERM CONSISTING OF CLAYEY MATERNAL SHALL BE CONSTRUCTED. THE SIDE SLOPES OF THIS EARTHEN BERM SHALL VARY. THE RNISHED SLOPE OF THE BERM SHALL, BE INSTALLED SUCH THAT THE SUM (EXTERIOR AND WTERIOR SLOPE FACES) OF THE HORaOWfAL C0101POMENT OF THE SLOPE ft-V) SHALL BEe E 4UAL To OR GREATER THAN 5, IN MO CASE SHALL THE INTERIOR OR EXTERIOR SCOPES BE INSTALLED STEEPER THIN 1.V ftly) FOR EROSION CONTROL PURPOSES THE EXTERIOR SLOPE SHALL BE: ARfMORIZED VOTH A LAYER OF CLASS A RIP4W. EFUM LINER INSTALLATION OF -TAIL NOT TO SCALE iN DATE DRAM: CHECKEa U: NOTE: A Di ARK ADGRESSBR COMMENT" FROM THE STATE ' AB ARK ARK RMSED BERM MNSTRUCT[OrVEPOM LINER DETAll— r ! ! Y_- W.S. E . = 242. _ ORM E1 N F BOTTOM V} WIDTH i f i SECTION A-, NOT TO SCALE 245 _ram E 240 Ii 2355 PROPOSED MOE 230 LEGEND r EXISTING CONTOUR 225 c CL cue 7 s ■on. ■O■ ■M■ z cn 0 z m C) C n n m CD CD ti DATE: 11.21-07 NC DENR DWQ Stormwater Permitting Unit 1617 Mail Service Center Raleigh, INC 27699-1617 Attn: Mr. Ken Pickle Dear Mr. Pickle: ■■■ ■■■ 0"Hanson HEIDELBERGCEMENTG coup Hanson Aggregates 8508 Freeport Parkway sulfa 500 Irving, Texas 75063 Phone 469 417 1249 Fax 469 417 1400 Allen. KinfiA Hanson.corn www,hanson.com October 15, 2008 The Hanson Aggregates, Inc., Crabtree Quarry, Raleigh N.C., Mid East Region, Detention Basin Drawing, dated November 07 has been modified as of October 15, 2008. Modifications to this drawing include the following: 1. Notation added to the EPDM Liner Installation Detail: NOTE: PRIOR TO THE INSTALLATION OF THE EDPM LINER, AN EARTHEN BERM CONSISTING OF CLAYEY MATERIAL SHALL BE CONSTRUCTED. THE SIDE SLOPES OF THIS EARTHEN BERM SHALL VARY. THE FINISHED SLOPE OF THE BERM SHALL BE INSTALLED SUCH THAT THE SUM (EXTERIOR AND INTERIOR SLOPE FACES) OF THE HORIZONTAL COMPONENT OF THE SLOPE (H:V) SHALL BE EQUAL TO OR GREATER THAN 5. IN NO CASE SHALL THE INTERIOR OR EXTERIOR SLOPES BE INSTALLED STEEPER THAN 1.5:1 (H:V) FOR EROSION CONTROL PURPOSES THE EXTERIOR SLOPE SHALL BE ARMORIZED WITH A LAYER OF CLASS B RIP -RAP 2. The plan view has been revised to show that the exterior slope of the berm is to be armorized with Class B rip rap, with a filter fabric under liner. The plan view has been modified to delineate the armorized slope and the EPDM Liner Installation detail has been noted as such. Mr. Don S Bright 11, PE will be overseeing the installation of this basin. We trust that this information is sufficient for your review and approval. Should you have additional questions feel tree to contact me. Sincerely, Allen R. King, PE Mine Planning Manager FIR Don S Bright II, PE Civil Engineer SUIW LOCATION ` J PLAN VIEW GRAPHIC SCALE: is 20 ao a ao m w SECTION A - A NOT TO SCALE EMM POMD LMER r STOW t- �EA�RI�IENiERY Tf - d30-r COMPACTED M.L —� ri- TOE ANCHOR EPDM LINER INSTALLATION DETAIL NOT TO SCALE M 240 236 "a z a m x o_ w a a3x� - w�e term wr�nas - vo nc iacn.2w: ... _.— -,A: 3_«_ a ._. _ . ..s , _ . . _. . _ .. — _ >�_ ......; I ..1,:. —ii! LS_ .._i '_ . 11 . 1 - NEW DISCHARGE--- -.-- — — \ 'z// \ .a.....-_ a a m. f r%"@ + soar-r.nam ATan►L SLOPE STABILIZATION SEEDING SCHEDULE i MAR. 1 -JUN. 1 SERICEA LESPEDEZA (SCARIFIED) �r 50 LBSIACRE (MAR. 1 - APR. 15) ADD TALL FESCUE 120 LBSIACRE (MAR. i - JUN. 30) OR ADD WEEPING LOVERGRASS 10 LBSIACRE (MAR. 1 -JUN. 30) OR ADD HULLED COMMON BERMUD SS 25 LBSIACRE JUN. 1 - SEP. 1 *** TALL FESCUE AND 120 LBSIACRE *** BROWNTOP MILLET 35 LBSIACRE OR SORGHUM - AN HYBRIDS 30 LBSIACRE SEP. 1 - MAR. 1 SERICEA LESPED (UNHULLED - UNSCARIFIED) 70 LBSIACRE AND TALL F UE 120 LBSIACRE NOV. 1 - MAR. I ADD ABRUZZI RYE 25 LBSIACRE CONSULT CONSERVATION ENGINEER OR SOIL CONSERVATION SERVICE FOR ADDITIONAL IN- FORMATION CONCERNING OTHER ALTERNATIVES FOR VEGETATION OF DENUDED AREAS. THE ABOVE VEGETATION RATES ARE THOSE WHICH DO WELL UNDER LOCAL CONDITIONS, OTHER SEEDING RATE COMBINATIONS,ARE POSSIBLE. *** TEMPORARY'- RESEED ACCORDING TO OPTIMUM SEASON FOR DESIRED PERMANENT VEGETATION. DO NOT ALATEMPORARY COVER TO GROW OVER 12" IN HEIGHT BEFORE MOWING,OTHERWISE FESCUE MAY BE SHADED OUT. so REINFORCED EPDM POND LINER TOP WIDTH 45 MN VARIABLE VARIABLE \ (SEE NOTE) (SEE NOTE) GLA I 6- THICK STONE RIP P EARTH�EN BiEI LINER 14" BE NG—I 1 1 r—! 1 1 —1 ! dew 7- THI ESS—!!++(-.CyyLAiIY__E IY MATERIJ II _ COMPACTED FILL TOE ANCHOR NOTE: PRIOR TO THE INSTALLATION OF THE EPDM LINER, AM EARTHEN BERM CONSISTING OF CLAYEY MATERIAL SHALL BE CONSTRUCTED. THE SIDE SLOPES OF THIS EARTHEN BERM SHALL VARY. THE FINISHED SLOPE OF THE BERM SHALL BE INSTALLED SUCH THAT THE SUM (EXTERIOR AND INTERIOR SLOPE FACES) OF THE HORIZONTAL COMPONENT OF THE SLOPE (H:V) SHALL BE EQUAL TO OR GREATER THAN & IN NO CASE SHALL THE INTERIOR OR EXTERIOR SLOPES BE INSTALLED STEEPER THAN 1.5:1 (H:V) FOR EROSION CONTROL PURPOSES THE EXTERIOR SLOPE SHALL BE ARMORIZED WITH A LAYER OF CLASS A RIP -RAP. EPDM LINER INSTALLATION DETAIL NOT TO SCALE FLOAT CONTROL SWITCH 243.5' EMERGENCY OFF 241.0'PUMP ONOFF 1"L' 236.0 SUMP BOTTOM 4" TYPICAL SUMP DETAIL NOT TO SCALE ' SUCTION LINE FROM PUMP - FLOW CHAIN/ ROPE F -� I (- BASKET STRAINER REVISION DATE DRAWN: CHECKED: NOTE: 2104M8 DJ ARK ADDRESSED COMMENTS FROM THE STATE 0I14M ARK ARK REVISED BERM CONSTRUCTIONIEPDM LINFR DETAIL CLASS "B" RIP RAP 18" BEDDING THICKNESS LEGEND EXISTING CONTOUR UPDATED EXISTING CONTOUR PROPOSED CONTOUR +"&4a0 SPOT ELEVATION EXISTING STRUCTURE PLAN VIEW SECTION THROUGH WEIR EPDM POND 60 mil 6" THICK STONE LINER _ d50 = 2" TOE ANCHOR EMERGENCY SPILLWAY DETAIL NOT TO SCALE TOP OF BERM: 245. 1�FLOW REEBOARD DEPTH CREST OF WEIR: TOE OF BERM: 2.40.0 O C IA � v IG $ F a C M�U-�Cc .r.0�0�Fw c Q 7 2 z Lu a Lu z MEN IDATE: 11-21-07 v z .rr W OC z W � z W oC 0: W W m z � � a z m a m z 0 P z w W 0 DESIGNED: ARK DRAWN: DJ CHECKED: ARK DATE: 14OV-07 REGION: MIDEAST CATION - CRAB EARTH BERM.DWG DWG FILE: SCALE: HORIZONTAL: 1"=20` VERTICAL: SHEET NO.: I OF: i I°s'� � ! i1 'I,z �',. 1� gill e1�.+�Ir��, 1 Ilr������{• ;1 I � 1�i ­ __.. _. _ ! • - -- 2"___ _— 1. .... __ ._ . I' L'•_. ...')'. ,. _ _. nl-'Iy l!f'_A:i Ly. CLL% 317!.L.]. A'I t t E 0 l 0 NEW DISCHARGE - PIPE (TO PIT) NEW PUMP LOCATION ;(AND BACK UP PUMP) 3500 GPM CAPACITY EXISTING BASIN ._ SUMP LOCATION GENCY SPILL SECTION SEE DETAIL _ ...... : EPDM MEMBRANE - - y_- LINER : -- SEE DETAIL ---�_v ........... ... �...... _ ........... " "" \ f� AREA TO BE STABILIZED = WITH _� --- --� O y � - SLOPE STABILIZATION SEEDING SCHEDULE MAR. 1 - JUN. 1 SERICEA LESPEDEZA (SCARIFIED) 50 LBSIACRE $c (MAR. 1 - APR. 15) ADD TALL FESCUE 120 LBSIACRE (MAR. 1 - JUN. 30) OR ADD WEEPING LOVERGRASS 10 LBSIACRE (MAR. 1 -JUN. 30) OR ADD HULLED COMMON BERMUDAGRASS 25 LBSIACRE JUN. 1 - SEP. 1 *** TALL FESCUE AND 120 LBSIACRE BROWNTOP MILLET 35 LBSIACRE *** OR SORGHUM - SUDAN HYBRIDS 30 LBSIACRE SEP. 1 - MAR. 1 SERICEA LESPEDEZA (UNHULLED - UNSCARIFIED) 70 LBSIACRE AND TALL FESCUE 120 LBSIACRE NOV. 1 - MAR. 1 ADD ABRUZZI RYE 25 LBSIACRE CONSULT CONSERVATION ENGINEER OR SOIL CONSERVATION SERVICE FOR ADDITIONAL IN- FORMATION CONCERNING OTHER ALTERNATIVES FOR VEGETATION OF DENUDED AREAS. THE ABOVE VEGETATION RATES ARE THOSE WHICH DO WELL UNDER LOCAL CONDITIONS, OTHER SEEDING RATE COMBINATIONS ARE POSSIBLE. *** TEMPORARY -- RESEED ACCORDING TO OPTIMUM SEASON FOR DESIRED PERMANENT VEGETATION. DO NOT ALLOW TEMPORARY COVER TO GROW OVER 12" IN HEIGHT BEFORE MOWING,OTHERWISE FESCUE MAY BE SHADED OUT. VARIABLE (SEE NOTE) REINFORCED EPDM POND / LINER 45 mil VARIABLE (SEE NOTE) CLASS "B" 1 ITf f-1 I 1=1 _ 1 6" THICK STONE RIP RAP I EARTHEN BERM; I LINER IV BEDDING _— 1 I� i E [—E E t—E t E—I —I f = d50 _ 2" THICKNESS I -I I -(CLAYEY MATERIAL) I I=71I— I FILTER FABRIC COMPACTED FILL UNDER LINER 1' TOE ANCHOR NOTE: PRIOR TO THE INSTALLATION OF THE EPDM LINER, AN EARTHEN BERM CONSISTING OF CLAYEY MATERIAL SHALL BE CONSTRUCTED. THE SIDE SLOPES OF THIS EARTHEN BERM SHALL VARY. THE FINISHED SLOPE OF THE BERM SHALL BE INSTALLED SUCH THAT THE SUM (EXTERIOR AND INTERIOR SLOPE FACES) OF THE HORIZONTAL COMPONENT OF THE SLOPE (H:V) SHALL BE EQUAL TO OR GREATER THAN S. IN NO CASE SHALL THE INTERIOR OR EXTERIOR SLOPES BE INSTALLED STEEPER THAN 1.5:1 (H:V) FOR EROSION CONTROL PURPOSES THE EXTERIOR SLOPE SHALL BE ARMORIZED WITH A LAYER OF CLASS B RIP -RAP. EPDM LINER INSTALLATION DETAIL NOT TO SCALE TOP WIDTH 5' I FLOAT CONTROL SWITCH 7 243.5' EMERGENCY OFF eS 241.0'PUMP ONfOFF 1' L 1' 6' E SUMP BOTTOM 4.r TYPICAL SUMP DETAIL NOT TO SCALE SUCTION LINE FROM PUMP FLOW CHAIN I ROPE � f I f� BASKET STRAINER REVISION DATE DRA1ft1N: CHECKED: NOTE: 2104108 DJ ARK ADDRESSED COMMENTS FROM THE STATE 10/15/08 ARK ARK REVISED BERM CONSTRUCTION/EPDM LINER DETAIL. ADDED CLASS B RIP -RAP ON SLOPE SECTION A -A NOT TO SCAL- E� CLASS "B" RIP RAP 18" BEDDING THICKNESS LEGEND EXISTING CONTOUR / UPDATED EXISTING CONTOUR PROPOSED CONTOUR -I-0" SPOT ELEVATION EXISTING STRUCTURE PLAN VIEW SECTION THROUGH WEIR EPDM POND 60 mil 6- THICK STONE LINER d50=2" TOE ANCHOR L EMERGENCY SPILLWAY DETAIL NOT TO SCALE � TOP OF BERM: 245. V FREEBOARD .5' FLOW DEPTH CREST OF WEIR: 243.50 TOE OF BERM: 240.0 O c 1a m op 0 Q d T L W f q 0 le ON NI°4 z X c CL 0 z F_ z 0 LLJ c U U m Lu Z ■■■ ■E■ ■■■ �R� CARC, ^Lill 22064 R jolID RATE: 11-21-07 0 z m W z ■ aa�0 Lu a�j z oto Z cy � W m v z W W ° a z Y/ a z 0 r_ z W W 0 DESIGNED: ARK DRAWN: DJ CHECKED: ARK DATE: NOV-07 REGION: MIDEAST LOCATION: - CRAB_EARTH_BERM.DWG DWG FILE: SCALE: HORIZONTAL: 1 "=20' VERTICAL: 1 "-20' SHEET NO.: OF: 'F+ { r I�,t• i1 ; ',. 4 r f rl � } 1�� �.-rr lr �'rt.i •' _I LZ = _ i_'idLLl_.__�.-...-.< �..._-_. .__-. c`it_- `�.�.�' .. ._ �I �i sL; is1--- -L-- -'�•i � L'?•.�..s1:: �:'_t'd_ii i 511 NEW PUMP LOCATION (AND BACK UP PUMP) 3500 GPM CAPACITY E f EXISTING BASIN SUMP LOCATION �FMERts NCY SPILL SECTION SEE DETAIL EPDM MEMBRANE LINER SEE DETAIL AREA TO BE STABILIZED CP-413 7REF ckE Fk NEW DISCHARGE PIPE (TO PIT) SLOPE STABILIZATION SEEDING SCHEDULE DISCHARGE - PIPE (TO PIT) EXISTING PUMP LOCATION (3500 CPM CAPACITY) MAR. 1 - JUN. ! SERICEA LESPEDEZA (SCARIFIED) 50 LBSIACRE (MAR. 1 - APR. 15) ADD TALL FESCUE 120 LBSIACRE (MAR. 1 -JUN. 30) OR ADD WEEPING LOVERGRASS 10 LBSIACRE (MAR. 1 -JUN. 30) OR ADD HULLED COMMON BERMUDAGRASS 25 LBS/ACRE JUN. 1 - SEP. 1 *** TALL FESCUE AND 120 LBSIACRE *** BROWNTOP MILLET 35 LBSIACRE *** OR SORGHUM - SUDAN HYBRIDS 30 LBSIACRE SEP. 1 - MAR. 1 SERICEA LESPEDEZA (UNHULLED - UNSCARIFIED) 70 LBSIACRE AND TALL FESCUE 120 LBSIACRE NOV_ 1 - MAR. 1 ADD ABRUZZI RYE 25 LBSIACRE CONSULT CONSERVATION ENGINEER OR SOIL CONSERVATION SERVICE FOR ADDITIONAL IN- FORMATION CONCERNING OTHER ALTERNATIVES FOR VEGETATION OF DENUDED AREAS. THE ABOVE VEGETATION RATES ARE THOSE WHICH DO WELL UNDER LOCAL CONDITIONS, OTHER SEEDING RATE COMBINATIONS ARE POSSIBLE. *** TEMPORARY -- RESEED ACCORDING TO OPTIMUM SEASON FOR DESIRED PERMANENT VEGETATION. DO NOT ALLOW TEMPORARY COVER TO GROW OVER 12" IN HEIGHT BEFORE MOWING,OTHERWISE FESCUE MAY BE SHADED OUT. NOTE: BASE TOPOGRAPHIC INFORMATION AND MAPPING PROVIDED BT CONTINENTAL AERIAL SURVEY; DATED AUG. 03. SPOT SHOT ELEVATIONS OF AS -BUILT CONDITIONS PROVIDED BY GROUND SURVEY; DATED OCT. 07. G PLANT AREA PLAN-1EW GRAPHIC SC 40 20 10 0 10 20 REINFORCED EPDM POND LINER TOP WIDTH 45 mil VARIABLE VARIABLE (SEE NOTE) (SEE NOTE) CLASS "B" 1 I I� I I_j I ►—I _ ^� 1 6" THICK STONE RIP RAP _EARTHEN BEp _ LINER 18" BEDDING _ t l r—I I t—tRM: I: —I k I —I I d60 = 2" THICKNESS I —I I (CLAYEY MATERIAL) i I� I j=III _ — I11=III=1 I I=1(i 1' FILTER FABRIC COMPACTED FILL UNDER LINER 1. TOE ANCHOR NOTE: PRIOR TO THE INSTALLATION OF THE EPDM LINER, AN EARTHEN BERM CONSISTING OF CLAYEY MATERIAL SHALL BE CONSTRUCTED. THE SIDE SLOPES OF THIS EARTHEN BERM SHALL VARY. THE FINISHED SLOPE OF THE BERM SHALL BE INSTALLED SUCH THAT THE SUM (EXTERIOR AND INTERIOR SLOPE FACES) OF THE HORIZONTAL COMPONENT OF THE SLOPE (H:V) SHALL BE EQUAL TO OR GREATER THAN 5. IN NO CASE SHALL THE INTERIOR OR EXTERIOR SLOPES BE INSTALLED STEEPER THAN 1.5:1 (H:V) FOR EROSION CONTROL PURPOSES THE EXTERIOR SLOPE SHALL BE ARMORIZED WITH A LAYER OF CLASS B RIP -RAP. EPDM LINER INSTALLATION DETAIL NOT TO SCALE 245 240 235 230 225 FLOAT CONTROL SWITCH 243.5' EMERGENCY OFF _ul�_241.0'PUMP ON/OFF 1' 6' II 236.0' SUMP BOTTOM 4" — SUCTION LINE FROM PUMP - FLOW CHAIN 1 ROPE Z�l ~` BASKET STRAINER TYPICAL SUMP DETAIL NOT TO SCALE REVISION DATE DRAWN: CHECKED: NOTE. 2104108 DJ ARK ADDRESSED COMMENTS FROM THE STATE 10f15l08 ARK ARK REVISED BERM CONSTRUCTIONIEPDM LINER DETAIL, ADDED CLASS B RIP -RAP ON SLOPE I- - - --- '' -- -- - �------ ,-MAX. W.S. EL. - 242.7�- 245 -....._.._..._.--- .. y _,T) � (25 YRS STORM EVEN � 240 —-_------ g•- -- _�—.- 2 235 - - BOTTOM PROPOSED GRADE WIDTH ----' 230 SECTION A —A NOT TO SCALE CLASS "B" RIP RAP 18" BEDDING THICKNESS LEGEND EXISTING CONTOUR UPDATED EXISTING CONTOUR I PROPOSED CONTOUR +,°'.` SPOT ELEVATION M1 EXISTING STRUCTURE PLAN VIEW SECTION THROUGH WEIR EPDM POND 60 mil 6" THICK STONE LINER d50 = 2" TOE ANCHOR EMERGENCY SPILLWAY DETAIL NOT TO SCALE 225 TOP OF BERM: 245. V FREEBOARD ' FLOW DEPTH CREST OF WEIR: 243.50 TOE OF BERM: 240.0 V G 1p � 04naa m o: ad�T� cW�aa m m IL 0 w 00 J l =m�Fu: a 0 O z z Eu LLI Im W Lu ■■■ ■E■ man DATE: 11-21-07 0 z uW OC z a cc t� a Cy W ui �0 3F C7 F Q z O U Z le m v W J Q W 0 a z a m z O H z W I— W 0 DESIGNED: ARK DRAWN: Di CHECKED: ARK DATE: NOV-07 REGION: MIDEAST LOCATION: CRAB _EARTH_BERM.DWG DWG FILE: SCALE: HORIZONTAL: 1 "=20' VERTICAL: 1 "=20' SHEET NO.: OF: S 1 '' LI i' rir .ti -a I s• l-I s, � �!' d11)•1 f� �! I� t{� il' ! L ><{: j! �; bl 1_ • � �, ! �' I I I ` � 1 11.E f I . �5 � �., ! .,,; � � x • i � . `1/� 1 . � 4 �S i, t 'Crl � y 14, _ . NEW PUMP LOCATION .(AND BACK UP PUMP) 3500 GPM CAPACITY I. E 1� EXISTING BASIN SUMP LOCATION 3ENCY SPILL SECTION SEE DETAIL \ EPDM MEMBRANE LINER SEE DETAIL AREA TO BE STABILIZED WITH CLASS "B - C�QTR�E CAE �K NEW DISCHARGE PIPE (TO PIT) SLOPE STABILIZATION SEEDING SCHEDULE DISCHARGE - PIPE (TO PIT) - EXISTING PUMP LOCATION (3500 CPM CAPACITY) MAR. 1 - JUN. 1 SERICEA LESPEDEZA (SCARIFIED) 50 LBSIACRE & (MAR. 1 -APR. 15) ADD TALL FESCUE 120 LBSIACRE (MAR. 1 - JUN. 30) OR ADD WEEPING LOVERGRASS 10 LBSIACRE (MAR. 1 - JUN. 30) OR ADD HULLED COMMON BERMUDAGRASS 25 LBSIACRE JUN. 1 - SEP.1 *** TALL FESCUE AND 120 LBSIACRE *** BROWNTOP MILLET 35 LBSIACRE *** OR SORGHUM - SUDAN HYBRIDS 30 LBSIACRE SEP. 1 - MAR. 1 SERICEA LESPEDEZA (UNHULLED - UNSCARIFIED) 70 LBSIACRE AND TALL FESCUE 120 LBSIACRE NOV. 1 - MAR. 1 ADD ABRUZZI RYE 25 LBSIACRE CONSULT CONSERVATION ENGINEER OR SOIL CONSERVATION SERVICE FOR ADDITIONAL IN- FORMATION CONCERNING OTHER ALTERNATIVES FOR VEGETATION OF DENUDED AREAS. THE ABOVE VEGETATION RATES ARE THOSE WHICH DO WELL UNDER LOCAL CONDITIONS, OTHER SEEDING RATE COMBINATIONS ARE POSSIBLE. TEMPORARY -- RESEED ACCORDING TO OPTIMUM SEASON FOR DESIRED PERMANENT VEGETATION. DO NOT ALLOW TEMPORARY COVER TO GROW OVER 12" IN HEIGHT BEFORE MOWING,OTHERWISE FESCUE MAY BE SHADED OUT. NOTE: BASE TOPOGRAPHIC INFORMATION AND MAPPING PROVIDED BT CONTINENTAL AERIAL SURVEY; DATED AUG. 03. SPOT SHOT ELEVATIONS OF AS -BUILT CONDITIONS PROVIDED BY GROUND SURVEY; DATED OCT. 07. NG PLANT AREA' PLA %IEWGRAPH 40 20 10 0 10 20 REINFORCED EPDM POND LINER TOP WIDTH 45 mil 5' VARIABLE VARIABLE (SEE NOTE) (SEE NOTE) CLASS "B" 1 ff f f f f ff 1 6" THICK STONE RIP RAP 4 _EARTHEN BERM _ LINER 18" BEDDING —1 III—III—t i I I� I _ d50 = 2" THICKNESS _ �—{CLAYEY MATERIAL)- I I� I I—� I I— f�iHIHI1=II1ICI 1' FILTER FABRIC COMPACTED FILL UNDER LINER 1 TOE ANCHOR NOTE: PRIOR TO THE INSTALLATION OF THE EPDM LINER, AN EARTHEN BERM CONSISTING OF CLAYEY MATERIAL SHALL BE CONSTRUCTED. THE SIDE SLOPES OF THIS EARTHEN BERM SHALL VARY. THE FINISHED SLOPE OF THE BERM SHALL BE INSTALLED SUCH THAT THE SUM (EXTERIOR AND INTERIOR SLOPE FACES) OF THE HORIZONTAL COMPONENT OF THE SLOPE (H:V) SHALL BE EQUAL TO OR GREATER THAN 5. IN NO CASE SHALL THE INTERIOR OR EXTERIOR SLOPES BE INSTALLED STEEPER THAN 1.5:1 (H:V) FOR EROSION CONTROL PURPOSES THE EXTERIOR SLOPE SHALL BE ARMORIZED WITH A LAYER OF CLASS B RIP -RAP. EPDM LINER INSTALLATION DETAIL NOT TO SCALE 245 240 235 230 225 FLOAT CONTROL SWITCH 243.5' EMERGENCY OFF 241.0'PUMP ONIOFF 1' L 1' 6' I -Ili `III a o II 2: i 0' SUMP BOTTOM 4" -- TYPICAL SUMP DETAIL NOT TO SCALE SUCTION LINE FROM PUMP CHAIN 1 ROPE FI-� 1I- - \ I I BASKET STRAINER FLOW REVISION DATE I DRAWN: CHECKED: NOTE: 2104l08 DJ ARK ADDRESSED COMMENTS FROM THE STATE 10115/08 ARK ARK REVISED BERM CONSTRUCTIONIEPDM LINER DETAIL, ADDED CLASS B RIP -RAP ON SLOPE SECTION A -A N07 TO SCALE CLASS "B- RIP RAP 18" BEDDING THICKNESS LEGEND EXISTING CONTOUR UPDATED EXISTING CONTOUR PROPOSED CONTOUR +,°o:' SPOT ELEVATION M1* EXISTING STRUCTURE PLAN VIEW SECTION THROUGH WEIR EPDM POND 60 mil 6" THICK STONE LINER d50 = 2" TOE ANCHOR EMERGENCY SPILLWAY DETAIL NOT TO SCALE TOP OF BERM: 245. V FREEBOARD .5' FLOW DEPTH CREST OF WEIR: 243.50 TOE OF BERM: 240.0 LI G W R Mao F O a ISi��rw IL r ti >Gwaa m 0 IL Rz aj_IK = ca U. CL 2 0 Lu O V z U Lj m J LY Mu Z ■■M ■E■ SEE 4? 14 DATE: 11-21-07 z W z a W a z W o W W — z a r. DESIGNED: ARK DRAWN: DJ CHECKED: ARK DATE: NOV-07 REGION: MIDEAST LOCATION: - CRAB_EARTH_BERM.DWG DWG FILE: SCALE: HORIZONTAL: 1 •=20' VERTICAL: 1 "=20' SHEET NO.: 1 OF: 13 V ' -TT-aF S'1_-i J,{ ?.1'Ir• 'F' 7145 IT 1 1 '� i. t . "1 � tt ) I