Loading...
HomeMy WebLinkAboutSW1190801_Form_(Supp.EZ)_20200610SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION -- 1 Protect Name Leicester Volunteer Fire Department 2 Project Area ac 10.68 3 Coastal Wetland Area ac _ 0 4 Surface Water Area ac 0 5 Is this roject High or Low Density? High 6 Does this project use an off -site SCM? No NUM 11 Infiltration S stem 0 12 Bioretention Cell 2 13 Wet Pond 0 14 Stormwater Wetland 0 15 Permeable Pavement 0 16 Sand Filter 0 17 Rainwater Harvesting RWH 0 18 Green Roof 0 19 Level Spreader -Filter Strip LS-FS 0 20 113isconnected Impervious Surface (DIS) 0 21 Treatment Swale 0 22 Dry Pond 0 23 StormFilter 0 24 Silva Cell 0 25 Ba filter 0 26 Filterra - 0 FORMS LOADED bLfKVmfflFICATION 27 Name and Title: Jacob D. Grieb 28 Organization: Mattern & Craig 29 Street address: 403 E. Market Street 30 City, State, Zip: Johnson City, TN 37601 31 Phone numbers : 423-979-2220 32 Email: jdgrieb@matternandcraig.com Cedifcalion Statement I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision; that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. Signatur Designer Data DRAINAGE AREAS 1 Is this a high density project? Yes 2 If so, number of drainage areas/SCMs 2 3 Is all/part of this project subject to previous rule versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site 1 2 4 Type of SCM Bioretention Cell Bioretention Cell Bioretention Cell 5 Total BUA in project (sq ft) 74199 sf 42254 sf 47045 sf 6 New BUA on subdivided lots (subject to permitting) (sq ft 0 sf 0 sf 0 sf 7 New BUA outside of subdivided lots (subject to permitting) (sf) 74199 sf 42254 sf 31945 sf 8 Offsite - total area (sq ft sf 0 sf 44742 sf 9 Offsite BUA (sq ft) 0 sf 0 sf 15100 sf 10 1 Breakdown of new BUA outside subdivided lots: Parking (sq ft) 16396 sf 6156 sf 10240 sf Sidewalk (sq ft 1663 sf 0 sf 1663 sf Roof (sq ft) 24640 sf 21184 sf 3456 sf Roadway s ft 31500 sf 14914 sf 16586 sf Future (sq ft) 0 sf 0 sf 0 sf Other, please specify in the comment box below (sq ft 0 sf 0 sf 0 sf 11 New infiltrating permeable pavement on subdivided lots (sq ft) 0 sf 0 sf 0 sf 12 New infiltrating permeable pavement outside of subdivided lots (sq ft 0 sf 0 sf 0 sf 13 Exisitng BUA that will remain (not subject to permitting) (sq ft) sf 0 sf 0 sf 14 Existin BUA that is already permitted (sq ft sf 0 sf 0 sf 15 1 Existing BUA that will be removed (sq ft) sf 0 sf 0 sf 16 Percent BUA 16% 69% 40% 17 Design storm (inches) 1 in 1 in 18 Design volume of SCM cu ft 3405 cf 3989 cf 19 Calculation method for design volume Simple Method Simple Method ADDITIONAL INFORMATION 20 Please use this space to provide any additional information about the drainage area(s): BIORETENTION CELL 1 Drainage area number 1 2 2 IDesign volume of SCM (cu ft) 3405 cf 3989 cf GENERAL MDC FROM 02H .1050 3 Is the SCM sized to treat the SW from all surfaces at build -out? Yes Yes 4 Is the SCM located away from contaminated soils? Yes Yes 5 What are the side slopes of the SCM (H:V)? 3:1 3:1 6 Does the SCM have retaining walls, gabion walls or other engineered side slopes? No No 7 Are the inlets, outlets, and receiving stream protected from erosion (10-year storm)? Yes Yes 8 Is there an overflow or bypass for inflow volume in excess of the design volume? What is the method for dewatering the SCM for maintenance? Yes Yes 9 Pump (preferred) Pump (preferred) 10 If applicable, will the SCM be cleaned out after construction? Yes Yes 11 Does the maintenance access comply with General MDC (8)? Yes Yes 12 Does the drainage easement comply with General MDC (9)? Yes Yes 13 If the SCM is on a single family lot, does (will?) the plat comply with General MDC (10)? 14 Is there an O&M Agreement that complies with General MDC (11)? Yes Yes 15 Is there an O&M Plan that complies with General MDC (12)? Yes Yes 16 Does the SCM follow the device specific MDC? Yes Yes 17 Was the SCM designed by an NC licensed professional? Yes Yes BIORETENTION CELL MDC FROM 02H .1052 18 SHWT elevation (fmsl) < 2161.00 < 2149.00 19 Bottom of the bioretention cell (fmsl) 2163.50 2151.50 20 Ponding depth of the design storm (inches) 12 in 12 in 21 Surface area of the bioretention cell (square feet) 3757 sf 4045 sf 22 Design volume of the bioretention cell (cubic feet) 3405 cf 3989 cf 23 Is the bioretention cell used for peak attenuation? Yes Yes 24 Depth of peak attenuation over planting surface (in) 24 in 24 in 25 Height of peak attenuation outlet above the planting surface (in) 18 in 18 in 26 Infiltration rate of the in situ soil (inch/hour) N/A N/A 27 Diameter of the underdrain pipes (if applicable) 4" 4" 28 Does the design include Internal Water Storage (IWS)? Yes Yes 29 1 if so, elevation of the top of the IWS (fmsl) 2165.5 2153.5 30 Elevation of the planting surface (fmsl) 2167 2155 31 What type of vegetation will be planted? (grass, trees/shrubs, other)? Other Other 32 Media depth (inches) 30 in 30 in 33 Percentage of medium to coarse washed sand by volume 75-80% 75-80% 34 Percentage of fines (silt and clay) by volume 8-10% 8-10% 35 1 Percentage of organic matter by volume 5-10% 5-10% 36 Type of organic material ie: pine bark ie: pine bark 37 Phosphorus Index (P-Index) of media (unitless) <50 <50 38 Will compaction be avoided during construction? Yes Yes 39 Will cell be maintained to a one inch/hour standard? Yes Yes 40 Depth of mulch, if applicable (inches) N/A N/A 41 Type of mulch, if applicable N/A N/A 42 How many clean out pipes are being installed? 2 2 43 Type of pretreatment that will be used: N/A N/A ADDITIONAL INFORMATION Please use this space to provide any additional information about the 44 bioretention cell(s): 31. Sod Bioretention 1 8:46 AM 6/4/2020